Datasheet Ref: ONS-BS-INS-IS-FR
300 / 500v                      Onshore Instrumentation Cables to BS5308 Specification
  Flame Retardant
Multi Pair Armoured Cables – Individually Screened – To BS5308 Part 1 Type 2
                                                                                                                                             Applicable Standards:
                                                                                                                                                    BS 5308
                                                                                                                                                    BS 6234
                                                                                                                                                    BS 7655
                                                                                                                          Solid class 1, Stranded class 2 or
                                                                                                                      flexible class 5 copper conductors to
                                                                                                                                                    BS6360
                                                                                                                        IEC 60332 Part 3 (Category A,B & C)
                               7          6                              3         2        1
            8                                           5      4
                                              Ideal for the petrochemical industry, these cables are designed to connect electrical
                     Application:             instrument circuits and provide communication services in and around process plants
                                              and are also suitable for direct burial applications.
                  (1) Conductor:              Solid (class 1), Stranded (class 2) or Flexible (class 5) Copper Conductors to BS6360
                Fire Protection:              None
                  (2)Drain Wire:              Tinned Copper drain wire
                  (3) Insulation:             Polyethylene Insulation type 03 Complying with BS6234
         (4) Individual Screen:               Aluminium Mylar Tape Screen
         (5)Collective Screen:                Aluminium Mylar Tape Screen
                   Binder Tape:               PETP Tape 50% Overlap
                    (6) Bedding:              Polyethylene Bedding Type 2C or 03 to BS6234
                     (7) Armour:              Mild Galvanised Steel Wires to BS EN 10257-1
            ( 8) Outer Sheath:                PVC outer sheath type TM.1 to BS7655. In addition the outer sheath displays the following
                                              Characteristics:
                                              -Minimum Oxygen Index: 30%
                                              -Maximum HCL Emission at 800C : 15%
                                              The legend will include the manufacturers name, voltage, BS5308, the number of pairs/triples
                                              and cross sectional area, cable sheath class (e.g. Polyethylene), and IEC60332 where
                                              applicable. The standard sheath colours are Black or Blue, and other colours are available
                                              on request.
    Conductor Identification:                 See Page 5
                                                                                                     INTERKAB House, Links Place, Aberdeen, AB11 5DY
                                                                                                                              Tel: 0044 (0)1224 595 640
                                                                                                                              Fax: 0044 (0)1224 594 416
                                                                                                         Email: info@internationalcablemanagement.com
                                                                                                  Datasheet Ref: ONS-BS-INS-IS-FR
   300 / 500v                           Onshore Instrumentation Cables to BS5308 Specification
  Flame Retardant
Multi Pair Armoured Cables – Individually Screened – To BS5308 Part 1 Type 2
                            2x2x0.5        5x2x0.5     10x2x0.5      20x2x0.5         30x2x0.5        50x2x0.5     2x2x0.75     5x2x0.75
           Cable
       Stranding mm         16/0.20        16/0.20      16/0.20       16/0.20         16/0.20          16/0.20      24/0.20      24/0.20
    Insulation Thickness      0.6            0.6          0.6           0.6             0.6              0.6          0.6          0.6
             mm
     Diameter over Inner   11.0/13.0      14.2/16.2    20.1/22.1     26.3/28.3        31.3/33.3       40.7/42.7    11.8/13.8    15.3/17.3
    Sheath (min/max) mm
        Diameter of          0.90           1.25         1.60          1.60                                          0.90         1.25
      Armour/Braid mm
      Overall Diameter     15.8/17.8      19.9/21.9    26.9/28.9     33.3/35.3        39.5/41.5       50.5/52.5    16.6/18.6    21.0/23.0
       (min/max) mm
         Gland Size            A              B            C            C2               D                D            A            B
       Weight kg/km           460            760         1300          1870             2400            3920          500          920
                               6              6            6             6               6                6            6            6
     Bend Radius - xOD
         Conductor
                             20/65          20/65        20/65         20/65           20/65            20/65        20/65        20/65
       Temperature –
        (min/max) °C
    Capacitance – pF/m        115            115          115           115             115              115          115          115
     DC Resistance @         39.7           39.7         39.7          39.7             39.7            39.7         26.5         26.5
       20°c –Ώ /km
     Maximum L/R Ratio        25             25           25            25               25              25           25           25
                           Black/Blue     Black/Blue   Black/Blue    Black/Blue      Black/Blue       Black/Blue   Black/Blue   Black/Blue
       Sheath Colour
                                                                                  INTERKAB House, Links Place, Aberdeen, AB11 5DY
                                                                                                           Tel: 0044 (0)1224 595 640
                                                                                                           Fax: 0044 (0)1224 594 416
                                                                                      Email: info@internationalcablemanagement.com
                                                                                                          Datasheet Ref: ONS-BS-INS-IS-FR
   300 / 500v                               Onshore Instrumentation Cables to BS5308 Specification
  Flame Retardant
Multi Pair Armoured Cables – Individually Screened – To BS5308 Part 1 Type 2
                              10x2x0.75        20x2x0.75     30x2x0.75     50x2x0.75          2x2x1.0          5x2x1.0     10x2x1.0     20x2x1.0
             Cable
          Stranding mm         24/0.20          24/0.20        24/0.2        24/0.2            1/1.13           1/1.13       1/1.13       1/1.13
       Insulation Thickness      0.6              0.6           0.6           0.6               0.6              0.6          0.6          0.6
                mm
       Diameter over Inner    21.7/23.7        28.8/30.8     34.5/36.5     44.0/46.0         11.8/13.8        15.2/17.2    21.6/23.6    28.8/30.8
      Sheath (min/max) mm
          Diameter of            1.60             2.00                                         0.90             1.25         1.60         2.00
        Armour/Braid mm
        Overall Diameter      28.5/30.5        36.8/38.8     42.9/44.9     54.0/56.0         16.6/18.6        20.9/22.9    28.4/30.4    36.8/38.8
         (min/max) mm
           Gland Size             C                C2            D             E                 A                B            C           C2
          Weight kg/km           1610             2420          3100          4900              515              950         1670         2540
                                  6                6             6             6                 6                6            6            6
       Bend Radius - xOD
           Conductor            20/65            20/65         20/65         20/65             20/65            20/65        20/65        20/65
          Temperature-
          (min/max) °C
      Capacitance – nF/KM        115              115           115           115               115              115          115          115
      DC Resistance @ 20°c       26.5             26.5          26.5          26.5             18.4             18.4         18.4         18.4
            –Ώ /km
       Maximum L/R Ratio          25               25            25            25               25               25           25           25
                              Black/ Blue      Black/ Blue   Black/ Blue   Black/ Blue       Black/Blue       Black/Blue   Black/Blue   Black/Blue
         Sheath Colour
                                                                                         INTERKAB House, Links Place, Aberdeen, AB11 5DY
                                                                                                                  Tel: 0044 (0)1224 595 640
                                                                                                                  Fax: 0044 (0)1224 594 416
                                                                                             Email: info@internationalcablemanagement.com
                                                                                                      Datasheet Ref: ONS-BS-INS-IS-FR
   300 / 500v                             Onshore Instrumentation Cables to BS5308 Specification
  Flame Retardant
Multi Pair Armoured Cables – Individually Screened – To BS5308 Part 1 Type 2
                             30x2x1.0        50x2x1.0      2x2x1.5      5x2x1.5           10x2x1.5          20x2x1.5    30x2x1.5     50x2x1.5
             Cable
         Stranding mm          1/1.13          1/1.13       7/0.53       7/0.53            7/0.53            7/0.53       7/0.53       7/0.53
      Insulation Thickness      0.6             0.6          0.6          0.6                0.6              0.6          0.6          0.6
               mm
      Diameter over Inner    34.4/36.4       43.9/45.9    13.7/15.7    17.8/19.8          25.5/27.5         33.4/35.4   40.0/42.0    51.2/53.2
     Sheath (min/max) mm
         Diameter of                                        1.25         1.60               1.60              2.00
       Armour/Braid mm
       Overall Diameter      42.8/44.8       53.9/55.9    19.4/21.4    24.4/26.4          32.5/34.5         41.6/43.6   49.8/51.8    61.6/63.6
        (min/max) mm
          Gland Size             D               E            B            C                 C2                D            D            E
         Weight kg/km          2900            4800          730         1180               1820              3030        4040         6000
                                 6               6            6            6                 6                 6            6            6
      Bend Radius - xOD
          Conductor            20/65           20/65        20/65        20/65             20/65             20/65        20/65        20/65
         Temperature -
         (min/max) °C
      Capacitance – pF/m        115             115          120          120               120               120          120          120
     DC Resistance @ 20°c      18.4            18.4         12.3         12.3               12.3              12.3        12.3         12.3
           –Ώ /km
      Maximum L/R Ratio         25              25           40           40                 40                40          40           40
                             Black/Blue      Black/Blue   Black/Blue   Black/Blue        Black/Blue        Black/Blue   Black/Blue   Black/Blue
        Sheath Colour
                                                                                    INTERKAB House, Links Place, Aberdeen, AB11 5DY
                                                                                                             Tel: 0044 (0)1224 595 640
                                                                                                             Fax: 0044 (0)1224 594 416
                                                                                        Email: info@internationalcablemanagement.com
                                                             Datasheet Ref: ONS-BS-INS-IS-FR
300 / 500v               Onshore Instrumentation Cables to BS5308 Specification
Flame Retardant
                           BS5308 Part 1 Core Identification
           Pair Number    Element A   Element B   Pair Number      Element A        Element B
                  1         Black       Blue          26             White            Yellow
                  2         Black      Green          27              Red             Yellow
                  3         Blue       Green          28             Orange           Yellow
                  4         Black      Brown          29              Black            Grey
                  5         Blue       Brown          30              Blue             Grey
                  6         Green      Brown          31             Green             Grey
                  7         Black       White         32             Brown             Grey
                  8         Blue        White         33             White             Grey
                  9         Green       White         34              Red              Grey
                  10        Brown       White         35             Orange            Grey
                  11        Black       Red           36             Yellow            Grey
                  12        Blue        Red           37              Black            Violet
                  13        Green       Red           38              Blue             Violet
                  14        Brown       Red           39             Green             Violet
                  15        White       Red           40             Brown             Violet
                  16        Black      Orange         41             White             Violet
                  17        Blue       Orange         42              Red              Violet
                  18        Green      Orange         43             Orange            Violet
                  19        Brown      Orange         44             Yellow            Violet
                  20        White      Orange         45              Grey             Violet
                  21        Red        Orange         46              Black          Turquoise
                  22        Black      Yellow         47              Blue           Turquoise
                  23        Blue       Yellow         48             Green           Turquoise
                  24        Green      Yellow         49             Brown           Turquoise
                  25        Brown      Yellow         50              White          Turquoise
                                                  INTERKAB House, Links Place, Aberdeen, AB11 5DY
                                                                           Tel: 0044 (0)1224 595 640
                                                                           Fax: 0044 (0)1224 594 416
                                                      Email: info@internationalcablemanagement.com