1.
Safety instructions                                 With safety pattern gauges (see dial symbol k
                        Operating                                                                                             or s) you need to pay attention to the fact that
                        Instructions                                             The user must ensure that the                the free space behind the blow-out back will be
                                                                                 appropriate pressure gauge with              at least 15 mm.
                                                                                 regard to scale range and performance
Pressure Gauges                                                                  and the appropriate wetted material           2.1 Requirements for the installation point
                                                                                 (corrosion) for the specific measuring
                                                                                                                              If the measuring point is not adequately stable a
                                                                       conditions of the respective application is selec-
                                                                                                                              measuring instrument support such as a bracket
                                                                       ted. In order to guarantee the accuracy and
                                                                                                                              or flange should be used for fastening (and
  Examples:                                                            long-term stability specified, the corresponding
                                                                                                                              possibly via a flexible capillary line). If the
                                                                       load limits are to be observed. Specifications:
                                                                                                                              pressure gauge is exposed to vibration or
                                                                       see data sheet under www.wika.de
                                                                                                                              pulsating pressure or both, then a liquid filled
                                                                       Only qualified persons authorised by the plant         pressure gauge may provide considerably better
                                                                       manager are permitted to install, maintain and         performance and readability. Instruments should
                                       Model 732.14,                   service the pressure gauges.                           be protected against coarse dirt and wide
                                     Overpressure safety                                                                      fluctuations in ambient temperature. EN 837-2
                                                                       Dangerous pressure media such as Oxygen,               "Selection and installation recommendations for
                                       up to 400 bar
                 Model 432.36,
                                                                       Acetylene, flammable gases or liquids, toxic           pressure gauges" should be complied with.
               Overpressure safety                                     gases or liquids as well as for refrigeration
                 up to 400 bar                                         plants or compressors requires attention above         3. Admissible ambient and working
                                                                       the standard regulations. Here the specific               temperatures
Model 213.40                                                           safety codes or regulations must be considered.
                                                                                                                              When installing the pressure gauge it has to be
                                                                       Serious injuries and/or damage can occur               ensured that, taking the influence of convection
                                                                       should the appropriate regulations not be              and heat radiation into consideration, no upper
                                                                       observed.                                              or lower deviation from the permissible ambient
                                                                                                                              and medium temperatures can occur. The
                                                                       2. Mechanical connection                               influence of temperature on the class accuracy
                                                                       According to the general technical regulations         is to be observed.
                                                                       for pressure gauges, respectively (i.e. EN 837-2).
                                                                                                                              4. Storage
                                                                       When screw-fitting the gauges the force
                                                                       required for this must not be applied through the      The pressure gauge should remain in its original
Notes according to                                                     case or terminal box but just through the              packing until installation. The gauge should be
Pressure Equipment Directive 97/23/EC                                  spanner flats (with suitable tool) provided for this   protected from external damage during storage.
                                                                       purpose.                                               Storage temperature: -40 °C ... +70 °C.
T The pressure gauges are "pressure accessories"                                                                              Pressure gauges removed from service should
   in accordance with article 1, paragraph 2.1.4                                                                              be protected from dust and humidity.
T The volume of the pressure bearing housings of                          Installation with
   WIKA pressure gauges is < 0.1 L                                        open-end wrench                                     5. Maintenance and servicing / Repairs
T The pressure gauges carry the CE marking for                                                                                The instruments require no maintenance or ser-
   fluid group 1G in accordance with annex 2,                                                                                 vicing. Tests should be carried out on a regular
                                                                       Correct sealing of pressure gauge connections          basis to guarantee the measuring accuracy of
   table 1 when their permissible working pressure                     with parallel thread ? shall be means of a
   exceeds 200 bar                                                                                                            the pressure gauge. The tests or recalibrations
                                                                       suitable sealing ring, sealing washer or WIKA          have to be carried out by qualified persons with
   Pressure gauges that do not carry the CE marking                    profile seals. The sealing of tapered threads (e.g.    the appropriate equipment. Remainder of the
   are manufactured in accordance with article 3,                      NPT threads) is made by providing the thread                     pressure medium contained in the
   paragraph 3 "sound engineering practice".                           @‚ with additional sealing material like, for                    pressure element may be hazardous or
                                                                       example, PTFE tape (EN 837-2).                                   toxic. This should be considered when
                                                                                                                                        handling and storing the removed
                                                                                                                                        pressure gauge.
Technical alteration rights observed.                                           wrench surface               sealing of
                                                                                                             the thread @     6. Applied standard
                                                                              sealing area ?
                                                                                                                              EN 837-1 Bourdon tube pressure gauges,
WIKA Alexander Wiegand GmbH & Co. KG                                                                                                   Dimensions, metrology, requirements
                                                                       The torque depends on the seal used. With
Alexander-Wiegand-Straße 30                                                                                                            and testing
                                                                       standard G-type pipe thread, gauge connection
                                                      2408 976 10.02
63911 Klingenberg • Germany                                                                                                   EN 837-2 Selection and installation recommen-
                                                                       by means of a union nut or a LH-RH adjusting
Phone (+49) 93 72/132-0                                                                                                                dations for pressure gauges
                                                                       nut is recommended to simplify correct
Fax    (+49) 93 72/132-406                                                                                                    EN 837-3 Diaphragm and capsule pressure
                                                                       orientation of the gauge.
E-Mail info@wika.de                                                                                                                    gauges, Dimensions, metrology,
www.wika.de                                                                                                                            requirements and testing