0% found this document useful (0 votes)
100 views2 pages

Organic Carbon, Total, Low Range: Required Reagents

This document provides instructions for analyzing total organic carbon using a direct method. It lists required reagents, apparatus, optional reagents, and optional apparatus for performing the analysis.

Uploaded by

Andreea Liliana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
100 views2 pages

Organic Carbon, Total, Low Range: Required Reagents

This document provides instructions for analyzing total organic carbon using a direct method. It lists required reagents, apparatus, optional reagents, and optional apparatus for performing the analysis.

Uploaded by

Andreea Liliana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

ORGANIC CARBON, TOTAL, Low Range (0.0–20.

0 mg/L C)
Direct Method* For water, drinking water, and wastewater

REQUIRED REAGENTS
Description Qty/Test Unit Cat. No.

Total Organic Carbon Direct Method Low Range


Test ’N Tube Reagent Set................................................................50 vials.......... 27603-45
Includes:
Acid Digestion Solution Vials, Low Range TOC...................1 ............. 50/pkg ............................. *
Buffer Solution, Sulfate ..................................................... 0.4 mL .........25 mL.............. 452-33
Funnel, micro ..........................................................................1 ................. each.......... 25843-35
Indicator Ampules, Low Range TOC.....................................1 ............. 10/pkg....................... *
TOC Persulfate Powder Pillows .............................................1 ............. 50/pkg....................... *
Water, organic-free** ......................................................... 3.0 mL .......500 mL.......... 26415-49
Silica 100 mg/L SiO2
Sulfate 5000 mg/L SO42-
Sulfide 20 mg/L S2-
Sulfite 50 mg/L SO32-
Zinc 5 mg/L
Table 1 Non-interfering Substances (Continued)
Substance Maximum Level Tested
* These items are not sold separately.
** This item must be purchased separately.

REQUIRED APPARATUS
Description Qty/Test Unit Cat. No.

Cylinder, graduated, 10-mL ................................................... 1..................each ..............508-38


DRB 200 Reactor, 110 V, 15 x 16 mm tubes ................................................. LTV082.53.40001
DRB 200 Reactor, 220 V, 15 x 16 mm tubes ................................................. LTV082.52.40001
Flask, Erlenmeyer, 50-mL...................................................... 1..................each ..............505-41
Magnetic Stirrer, 115 V, 4" x 4" ............................................. 1..................each ..........28812-00
Test Tube Rack......................................................................1-3................each ..........18641-00
Pipet, TenSette®, 0.1 to 1.0 mL.............................................. 1..................each ..........19700-01
Pipet, TenSette®, 1.0 to 10.0 mL............................................ 1..................each ..........19700-10
Pipet Tips, for 19700-01 TenSette® Pipet .............................. 2..............50/pkg ..........21856-96
Pipet Tips, for 19700-10 TenSette® Pipet .............................. 2..............50/pkg ..........21997-96
Stir Bar, Magnetic .................................................................. 1..................each ..........45315-00
Wipes, Disposable, Kimwipes................................................ 1............280/pkg ..........20970-00

OPTIONAL REAGENTS
Potassium Acid Phthalate..........................................................................500 g ..............315-34
Sulfuric Acid Reagent Solution, 5.25 N...................................... 100 mL MDB............2449-32
TOC Standard Solution Ampules (KHP Standard, 1000 mg/L C)............5/pkg ..........27915-05
Wastewater Effluent Standard, Inorganic
(NH3–N, NO3–N, PO4, COD, SO4, TOC) ..................................... 500 mL..........28332-49
OPTIONAL APPARATUS
Analytical Balance ......................................................................................each ..........28014-01
DRB 200 Reactor, 110 V, 21 x 16 mm and 4 x 20 mm.................................. LTV082.53.42001
DRB 200 Reactor, 220 V, 21 x 16 mm and 4 x 20 mm.................................. LTV082.52.42001
DRB 200 Reactor, 110 V, 9 x 16 mm and 2 x 20 mm.................................... LTV082.53.30001
DRB 200 Reactor, 220 V, 9 x 16 mm and 2 x 20 mm.................................... LTV082.52.30001
Flask, volumetric, 100-mL..........................................................................each ..........14574-42
Pipet, Class A, 200-mL ...............................................................................each ..........14515-35
Pipet, Class A, 15.00-mL ............................................................................each ..........14515-39