K.P.Mondal & Sons: Quality Assurance Plan

This quality assurance plan is for ductile iron dismantling joints to be supplied by K.P. Mondal & Sons to JMC Projects (I) Ltd. for the Jharkhand Mineral Area Development Authority project. The plan outlines the testing and inspection requirements for raw materials, final inspection, and marking to ensure the joints meet the necessary standards and specifications. Key checks include tensile strength, dimensions, surface quality, hardness, chemistry, leakage testing, paint thickness, and marking. Inspection and testing will be conducted by the manufacturer and witnessed by the client or third party as specified in the plan.

Uploaded by

Tanmoy Dutta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
272 views1 page

K.P.Mondal & Sons: Quality Assurance Plan

This quality assurance plan is for ductile iron dismantling joints to be supplied by K.P. Mondal & Sons to JMC Projects (I) Ltd. for the Jharkhand Mineral Area Development Authority project. The plan outlines the testing and inspection requirements for raw materials, final inspection, and marking to ensure the joints meet the necessary standards and specifications. Key checks include tensile strength, dimensions, surface quality, hardness, chemistry, leakage testing, paint thickness, and marking. Inspection and testing will be conducted by the manufacturer and witnessed by the client or third party as specified in the plan.

Uploaded by

Tanmoy Dutta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Client JMC Projects (I) Ltd.

K. P. M O N D A L & S O N S Project
JHARKHAND MINERAL AREA DEVELOPMENT AUTHORITY
Howrah Amta Road, Dasnagar, Howrah – 711 105 West Bengal End User
Ph: 033 - 2653 0673 Fax: 033 - 2653 0673; E-mail: contact@kpmvalves.com Manufacturer K.P. Mondal & Sons, Howrah
QAP No. KPM /QAP/DJ/2020-21/128
ITEM DESCRIPTION Ductile Iron Dismantling Joint Size MM 100 200 300 600 900 1000 Brand Name
DRG. NO. KPM/DJ/205/20-21
STANDARDS As Per Drawing, Qty. Nos. 10 17 37 17 19 07 KPM
QUALITY ASSURANCE PLAN
Sl. Item/Components/ Characteristics Type/Method of Extent of Reference Acceptance Format of Agency
Category
No Process Stage Checked Check Check Documents Norms Record M C TP
1. RAW MATERIALS
1.1 DJ Adaptor Body, DJ a) Tensile Strength Major Mechanical Test One Per Heat As per Drawing As per Drawing Test Report W R R
Adaptor Ring, DJ b) Dimensions Major Measurement 100% As per Drawing As per Drawing Insp. Report W R R
Spigot etc. d) Surface Major Visual 100% As per Drawing No Defects Insp. Report W R R
Compression “O”
1.2 a) Hardness Major Shore Hardness 100% As per Drawing ---------- Insp. Report W R R
Ring
a) Tensile Strength Major Mechanical Test One Per Heat As per Drawing As per Drawing Test Report W R R
1.3 Stud & Nut b) Chemical Major Chemical Analysis One Per Heat As per Drawing As per Drawing Test Report W R R
c) Dimensions Major Measurement 100% As per Drawing As per Drawing Insp. Report W R R

a) FINAL INSPECTION
2. Dimensional Check Dimension Major Measurement 10% As per Drawing As per Drawing Insp. Report P W W
Hydraulic Test Leakage test Major Shell Test 10% As per Drawing As per Drawing Insp. Report P W W
Painting & Surface
3. Visual & DFT Major DFT 100% As per Drawing As per Drawing Insp. Report P R R
Preparation
4. Marking Sl. No. PN Rating Major Visual 100% As per Drawing As per Drawing Insp. Report P R R

Legend : K. P. MONDAL & SONS CLIENT END USER CONSULTANT


M = Manufacturer, C = Client, TP = Third Party, PREPARED BY APPROVED BY REVIEWED BY APPROVED BY APPROVED BY APPROVED BY
P = Perform, V = Verification, W = Witness T DUTTA P.DEY H.MONDAL
Note :
a) 100% by Manufacturer and 10% By TPI/Client
b) Test Certificate will be according to BS EN 10204-3.1
or NABL Accredited Lab, whichever is available.