GOLDEN PACIFIC ELECTRONICS, INC.
560 South Melrose Street
Placentia, CA 92870
www.gpelectronics.com
Customer:
Customer Model Number:
Product Part Number: PXX2410AWPL05
1. SCOPE:
Purpose of this document is to specify the functional and requirements of the wall mount
AC-DC, 24W switching power supply with interchangeable AC input prong.
2. INPUT CHARACTERISTICS:
2.1 Input Voltage:
Nominal: 100 to 240 Vac.
Range: 90 to 264 Vac.
2.2 Input Frequency:
Nominal: 50 to 60 Hz.
Range: 47 to 63 Hz.
2.3 Input Current:
600mA rms maximum at the rated input voltage range and rated DC output load.
2.4 Inrush Current:
50Amps maximum at 100-240Vac input, cold start with rated DC output load
@ 25°C ambient
2.5 Stand-By Power
The input power shall be less than 0.3W with Zero load condition
3. OUTPUT CHARACTERISTICS:
3.1 Power
Voltage Min. Load Max. load Peak Output Power
24Vdc 0A 1.0A - 24W
3.2 Output Voltage
22.8V~25.2V no load
22.8V~25.2V full load
DWG Control Number: 91-0100XX-19
Revision: 1
Date: 08/17/09 Page 1 of 7
GOLDEN PACIFIC ELECTRONICS, INC.
560 South Melrose Street
Placentia, CA 92870
www.gpelectronics.com
3.3 Ripple and Noise:
Ripple and noise levels are measured at 20MHz bandwidth limit with parallel
capacitors (10uF and 0.1uF) connecting across the output of power supply.
Voltage Ripple and Noise (Max.)
+24Vdc 150mVp-p
3.4 Turn on delay:
During turn on and turn off, no output voltage shall exceed its nominal voltage by
more than 10% and no output shall change its polarity with respect to its return
line. All outputs shall reach their steady state values within 3 seconds of turn on.
3.5 Hold UP Time:
10ms minimum at 115Vac/60Hz input at maximum load. And 20ms minimum at
230Vac/50Hz input at maximum load.
3.6 Output Transient Response
The power supply shall maintain output transient response time within 800mV
with a loading current change from 20% to 80% of maximum current and 0.5A/µs
rise up/draw down test at tend of output terminal.
3.7 Efficiency;
The efficiency (watts out/watts in) shall be higher than typical while measuring at
nominal line and maximum load condition, test in 1 minute after power on.
3.8 Output Connectors Options:
Please see our Website www.gpelectronics.com
4. PROTECTION REQUIREMENT:
4.1 Over Voltage Protection:
Over Voltage Protection shall be included in the adaptor circuit; a single
component failure must not cause an over voltage condition.
4.2 Over Current Protection:
The adaptor must have a current limiting function on the output voltage. In
overload mode, the output must drop to a low voltage situation.
4.3 Short Circuit Protection:
The adaptor must withstand a continuous short circuit on the output without
damage.
DWG Control Number: 91-0100XX-19
Revision: 1
Date: 08/17/09 Page 2 of 7
GOLDEN PACIFIC ELECTRONICS, INC.
560 South Melrose Street
Placentia, CA 92870
www.gpelectronics.com
5. ENVIRONMENTAL REQUIREMENT:
5.1 Operating Temperature:
0 °C to 40 °C, at full load operation
5.2 Storage Temperature:
-10 °C to 60 °C
5.3 Relative Humidity:
10% ~ 90% “Altitude on sea level to 2,000 m
5.4 Vibration:
1.0mm, 10-55Hz, 15 minutes per cycle for each axis (X.Y.Z)
5.5 Cooling:
Natural convection cooling
5.6 Non-Operating
The power supply shall be capable of withstanding the following environmental
conditions extended periods of time, without sustaining electrical or mechanical
damage and subsequent operational deficiencies.
5.7 Vibration and Shock:
The power supply shall be designed to withstand normal transportation vibration
per MIL-STD-810D. method 514 and procedures X, as it is mounted in the
chassis assembly and packed for shipping as.
5.8 Reliability:
When the power supply is operating within the limits of this specification,
the MTBF will be approximately 50,000 hours @ 25 C (MIL-STD-217F).
5.9 Burn In:
The Power supply shall withstand a minimum of 4 hrs burn in test under full load
at 35˚C ~ 40˚C room temperature and unit shall be continued operating
respectfully.
5.10 Component De-rating:
Semiconductor junction temperatures shall not exceed manufacturer’s maximum
thermal rating.
DWG Control Number: 91-0100XX-19
Revision: 1
Date: 08/17/09 Page 3 of 7
GOLDEN PACIFIC ELECTRONICS, INC.
560 South Melrose Street
Placentia, CA 92870
www.gpelectronics.com
6. SAFETY APPROVALS:
Item Country Certified Standard
UL USA Approved UL60950-1
CSA C22.2
CUL Canada Approved
NO 60950-1
PART 15
FCC USA Approved
CLASS B
CE Europe Approved EN60950-1
GS Europe Approved EN60950-1
PSE Japan Meet to J60950
6.2 Insulation Resistance:
Input to output: 10 MΩ min at 500Vdc.
6.3 Dielectric Strength (Hi-Pot):
Primary to secondary DC4242V 3.5mA 1minute for type test, 3S for product.
6.4 Leakage Current:
The leakage current shall be less than 0.25mA for Class II when the power
supply is operated maximum input voltage and maximum frequency.
7. EMC STANDARDS
The power supply shall meet the radiated and conducted emission requirements for
EN55022 CLASS B, FCC PART 15 CLASS B. J55022 as well as EMS Series
(EN55024).
7.1 IEC61000-4-2 Electrostatic Discharge (ESD)
Static – discharge test by contract or air should be conducted with Static –
discharge teeter, energy storage capacitance of 150pf, and discharge resistance
of 330Ω. 8KV air discharge, 4KV contact discharge, Performance Criterion B
7.2 IEC61000-4-3 Radiated Electromagnetic Fields (RS)
Radio – frequency Electromagnetic Field Susceptibility Test, RS, 80-1000MHz,
3V/m, 80%AM(1KHz), Performance Criterion A.
DWG Control Number: 91-0100XX-19
Revision: 1
Date: 08/17/09 Page 4 of 7
GOLDEN PACIFIC ELECTRONICS, INC.
560 South Melrose Street
Placentia, CA 92870
www.gpelectronics.com
7.3 IEC61000-4-4 Electrical Fast Transient/Burst (EFT)
Power Line to Line: 1KV
Performance Criterion B
7.4 IEC61000-4-5 Lightning Surge Attachment
Lightning Surge voltage of differential and common modes shall be applied
across AC input lines and across input and frame ground.
Power Line to Line: 1KV
Line to Earth: ے
Performance Criterion B
7.5 IEC61000-4-6 Conducted Radio Frequency Disturbances (CS)
Conducted Radio Frequency Disturbances test, CS, 0.15-80 MHz, 3V/m,
80%AM, 1K Hz, Performance Criterion A
7.6 IEC61000-4-11 Voltage Dips/Short Interruption/Variations
Voltage Dips, 30% reduction – 10mS, Performance Criterion B, 60%
Reduction - 100mS, Performance Criterion C, Voltage Interruptions>95%
Reduction – 5000mS, Performance Criterion C
8. MECHANICAL CHARACTERISTICS:
8.1 Physical Dimensions:
Please see APPENDIX A for power supply dimensions.
8.2 Nameplate:
The label of the power supply, please see APPENDIX B.
8.3 Drop Test:
Dropped freely from 1m height (for wall mount product) onto the surface is
consisted of hardwood 13 mm thick, mounted on two layers of plywood each 19-
20mm thick, all supported on concrete floor 1 time from 3 different angle (X.Y.Z),
final test results, product shall be no damage without any condition.
9. OTHER REQUIREMENTS:
9.1 Energy Efficiency
The No-load power consumption shall be less than 0.3W at input 115/230Vac
The average active mode efficiency shall be higher than 82.09% at input
115/230Vac
DWG Control Number: 91-0100XX-19
Revision: 1
Date: 08/17/09 Page 5 of 7
GOLDEN PACIFIC ELECTRONICS, INC.
560 South Melrose Street
Placentia, CA 92870
www.gpelectronics.com
9.2 International Efficiency Level V
This power supply is therefore in compliance with the requirements of Energy
Star (EPS Version 2.0) for external power supplies
9.3 Hazardous Substances:
The components and materials used shall be compliant with EU directive
2002/95/EC “RoHS” mark on the unit label.
APPENDIX B: Nameplate
Unit: mm
Tolerance: +0/-0.2
Back Color: Black
Word Color: White
DWG Control Number: 91-0100XX-19
Revision: 1
Date: 08/17/09 Page 6 of 7
GOLDEN PACIFIC ELECTRONICS, INC.
560 South Melrose Street
Placentia, CA 92870
www.gpelectronics.com
APPENDIX A: Mechanical Drawing
(Unit: mm) Tolerance of unspecified parts ± 1.5mm
49.0±1.5 34.0±1.5
81.0±1.5
86.5±1.5 - +
SWITCHOVER PLUG
UL PLUG SAA PLUG
VDE PLUG BS PLUG
Section ØA ØB C D
Dimensions 2.1 5.5 12 1830
Tolerance +0.1/0 ±0.1 ±0.5 +50/-0
Remark AWG20# / 2C UL2468 BLACK
DWG Control Number: 91-0100XX-19
Revision: 1
Date: 08/17/09 Page 7 of 7