0% found this document useful (0 votes)
123 views2 pages

Pt100 RTD & Thermocouple Probes For Industrial Applications

This document provides information on temperature probes for industrial applications, including Pt100 RTD and thermocouple probes. It describes the probe types, styles, accuracies, diameters, lengths, mounting options, and lead wire specifications that are available. An ordering guide is included to help specify the desired probe configuration.

Uploaded by

Trung Dũng
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
123 views2 pages

Pt100 RTD & Thermocouple Probes For Industrial Applications

This document provides information on temperature probes for industrial applications, including Pt100 RTD and thermocouple probes. It describes the probe types, styles, accuracies, diameters, lengths, mounting options, and lead wire specifications that are available. An ordering guide is included to help specify the desired probe configuration.

Uploaded by

Trung Dũng
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Pt100 RTD &

Thermocouple Probes for


Industrial Applications
B

⻬ Pt100 in class A, 1/3 DIN and


1/10 DIN available
⻬ Thermocouples J, K, T, E & L
with accuracy to IEC class 1
⻬ Temperature range -100°C to
+400°C
⻬ Standard closed end sensors
or airstream models available
⻬ Standard lengths up to
200mm, optional lengths 0f
201-500mm
⻬ Diameter 3mm or 6mm
⻬ A range of mounting threads
⻬ All Pt100 sensors have a
4-wire connection
⻬ A broad range of lead wire
materials available

OMEGA temperature probes for


industrial applications are produced
with a wide variety of mechanical
attachment systems suitable for a
range of process conditions.
They may be specified to your
precise requirements by the sensor
type in either a closed-end or
airstream version, accuracy, probe
length, different threads, wire
material in shielded and unshielded
versions.

AVAILABLE VERSIONS:

Probe Mounting Lead Wire Lead Wire


Probe Type Style Accuracy Diameter
Length Bush Insulation Length
P-Pt100 M-Closed end P-Pt100(4-wire): 6-6mm 5-200mm O-Plain stem M12-M12 Connector XM-Cable
J-Thermocouple J L-Airstream Probe 3-3mm 200-500mm M6-M6x1 pitch P-PVC length in
K-Thermocouple K H-Hand Held A-Class A M8-M8x1 pitch S-Silicone Rubber metres
T-Thermocouple T Probe 1/3-1/3 DIN B M10-M10x1 pitch T-FEP
L-Thermocouple L EH-Hand-held 1/10-1/10 DIN B G1/8-1/8" BSP PI. G-Glass Fibre
E-Thermocouple E probe with G1/4-1/4" BSP PI PS-PVC Shielded
N-Thermocouple N penetration tip Thermocouples: G1/2-1/2" BSP PI. TS-FEP Shielded
GS-Glass Shielded
1-Class 1
(standard)
Specifications

RTDs
Temperature range: Response time T66 in liquid: The standard temperature range is -
-100°C to +400°C Pt100 closed end probe: 3 seconds 100°C to +400°C. Selection of the
Thermocouple: 4 seconds wire insulation, i.e. PVC, Silicone,
Lead wire temperature range:
PVC 100°C (max), Silicone rubber FEP or Glass will effect the
Response time T66 in air: maximum probe temperature. Do not
200°C (max), FEP 250°C (max), Pt100 closed end probe 15 seconds
Fibreglass 400°C (max) exceed the maximum temperature of
Thermocouples: 5 seconds the insulation at the transition
Sheath material: Sensor Configuration: between the probe and wire.
Stainless steel grade 304 Pt100: 4-wire system
Thermocouples: Ungrounded
Maximum pressure:
Ø6mm - 40bar, Ø3mm - 20bar

Ordering Guide
Model No Description Ordering Code
Probe Type Pt100 to IEC 751 P
Thermocouple type J, Iron/Constantan to IEC 584 J
Thermocouple type K, NiCr/NIAI to IEC 584 K
Thermocouple type T, Copper/Constantan to IEC 584 T
Thermocouple type L, Iron/Constantan to DIN 43710 L
Style Closed end M
Airstream probe L
Hand-held probe H
Hand-held probe with penetration tip EH
Sensor Accuracy* Class A (1/2 DIN Class B – Standard) A
Pt100 1/3 DIN Class B 1/3
1/10 DIN Class B 1/10
Thermocouples Class 1 (Standard) 1
Stem Diameter 6mm 6
3mm 3

Stem Length 5-200mm 5-200


201-500mm 201-500
Process Connection** Plain stem (Standard) 0
M6 x 1mm pitch thread (Ø3mm probes) M6
M8 x 1mm pitch thread M8
M10 x 1mm piktch thread M10
1/8" BSP Parallel (G1/8" ) G1/8"
1/4" BSP Parallel (G1/4" ) G1/4"
1/2" BSP Parallel (G1/2" – Ø6mm probes) G1/2"
Lead wire insulation M12 Plug Instead of Cable M12
(Price per metre) PVC 100°C maximum P
Silicone Rubber 200°C maximum S
FEP 250°C maximum T
Fibreglass 400°C maximum G
PVC with internal tinned copper braid 100°C maximum PS
FEP with internal tinned copper braid 200°C maximum TS
GS
Lead Wire Length*** xm X

* Thermocouples are supplied with Class 1 accuracy as standard. ** The probe diameters shown above are available with the thread sizes
indicated. *** The lead wire is supplied in multiples of one metre.
Ordering example 1: K-L-1-3-50-PS-1 Ordering example 2: P-M-1/3-6-100-M10-S-8
Thermocouple type K airstream probe with Class 1 accuracy and Pt100 closed end probe with 1/3 DIN accuracy and diameter of 6mm.
diameter of 3mm. The probe length is 50mm with 1 metre of PVC The probe length is 100mm with an M10 x 1 mounting bush and 8
shielded lead wire. metres of silicone lead wire.

You might also like