0% found this document useful (0 votes)
99 views2 pages

Flexible Options Comfortable Functions

The document describes the features and technical specifications of an infant radiant warmer. Key features include: 1. It uses microcontroller-based electronics and has controls for skin/air temperature, Apgar timer, and manual mode. 2. It has a sensor technology that automatically reduces the heater output to 30% if the skin temperature probe detaches from the baby's skin. 3. Technical specifications include temperature ranges and accuracy, alarm types, electrical safety certifications, and dimensions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
99 views2 pages

Flexible Options Comfortable Functions

The document describes the features and technical specifications of an infant radiant warmer. Key features include: 1. It uses microcontroller-based electronics and has controls for skin/air temperature, Apgar timer, and manual mode. 2. It has a sensor technology that automatically reduces the heater output to 30% if the skin temperature probe detaches from the baby's skin. 3. Technical specifications include temperature ranges and accuracy, alarm types, electrical safety certifications, and dimensions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

· i - Sense technology

(if the skin teamperature probe


detached from the baby skin,
the device automatically
sense and reduce the heater
output to 30%)

FLEXIBLE OPTIONS
COMFORTABLE FUNCTIONS

Neotech
Technical Specification
Infant Radiant Warmer
Features:
· Micro Controller based Electronics
· Controls: Skin/Air /Apgar and Manual
· Pre-warm: Use the equipment with 30% Heater Output
in Manual Mode.
· i - Sense technology
· No need of calibration required for temperature probe.
(if the skin teamperature probe
· High Intensity Quartz Heating element for effective
detached from the baby skin,
Radiation (Ceramic heater Optional)
the device automatically
· Halogen Observation Lamp
sense and reduce the heater
· The Heater Module rotates 90° to both sides to facilitate
output to 30%)
X-Ray Procedures.
· The Parabolic Reflector is designed to send uniform heat
to the bed surface.
· Memory Backup to restore set temperature and
previous mode, in case of power failure.
· Optimum Bed dimensions ensure optimum work space
for the nursing staff.
· Comprehensive Alarms and safety cut-offs.
· Programmable Mute time.
· Alert (Alarm) when sensor is detached from the
patient's skin(optional)
· Instant Warming and Uniform heating.
Optional (height Adjustment)
Main voltage : AC 230V/ 50 Hz. Apgar Timer : Alerts at 1,5,10,15 and 20 minutes
Max. power requirement : 700VA Selectable
Supply current : Maximum 3.2 Amps CPR Timer : 1 - 59 minutes selectable
Examination light : 50 W / 12 V AC Halogen lamp Heating element : Quartz IR heater(Standard)

Electronics : Highspeed Micro controller With self Mattress tilt : +/- 15 degrees
test function Heater Module Swivel : ±90° to the side to facilitate X -ray
Modes of operation : Servo Skin, Servo Air and Manual procedure
Castors : 4 Nos 4” (Antistatic with 2 brakes)
Controller Heating Alarms Heater watts : 600 VA
Skin Temp High : + 1 0 C from the2 set point
Skin Temp Low : - 1 0 C from the set point X-Ray cassette tray : 57cm (L) X 35cm (W)
Air Temp High : + 1 0 C from the set point IV pole : Maximum load : 1.5kg
Air Temp Low : - 1 0 C from the set point Monitor Tray : Swivel & Fixed Type Maximum Load
Over temperature : > 39 0 C ( Skin/Air) 2.5Kg
Probe failure : Short (or) Open circuit / No probe IEC 60601-1 Specification
System failure : Indicates system fail Type of protection against electric shock : Class 1
Heater failure : If heater fail Degree of protection against electric shock : Type BF (skin probe)
Power failure : AC power interruption Type B (Mattress)
Mode of Operation : Continuous
Alarm silence / Reset Intervals Protection against Hazardous of Explosion : Not Protected
Check patient : Resets clock for Every 15 minutes Protection against increases of liquid : Not Protected
(manual mode) MDD Product Classification : Class llb
Alarm silience :10 minutes
Controller Environmental
Skin set temp range : 32 - 380 C Operating Temperature : 100 C to 300 C
Air set temp range : 30 - 380 C Operating Relative Humidity : 15 to 90% RH non condensing
Heater output : 5% - 100%, 5% increments Storage Temperature : -100 C to 600 C
Skin/Air temp display : 10 - 50 0 C Storage Relative Humidity : 50 to 90% RH non condensing
Resolution : 0.1 0 C Altitude : Sea level to 1.9 miles (3 kms)
Accuracy : +/- 0.2 0 C (300 C to 50 0 C)
Temperature Conversion : Centigrade/Fahrenheit Dimensions
74-00-011, Rev 01

Temperature Calibration : No need of calibration Equipment : 192 cm (H) X 109 cm(L) X 68 c(W)
Skin probe : Thermistor based interchangeable Mattress : 73 cm (L) X 53 (W) cm X 5 cm (H)
with accuracy +/- 0.2 0 C Weight : 81 kgs
Air probe : Thermistor based interchangeable with
accuracy +/- 0.2 0 C Quality/Test approval
Noise level : < 50db Quality : ISO 13485:2016
Thermostat : Auto Reset 90 0 C +/- 5 0 C for infant Electrical safety : IEC 60601-1
warmer : IEC 60601-2-21
Control panel lock : Lock key provided EMC Safety : IEC 60601-1-2

Manual Mode : System alerts every set manual time


15 minutes with heater cutoff
. . .
Neotech

AN ISO 13485:2016 Company(with design)

Regd.Office & Factory:# 85 Krishna Industrial Estate, Mettukuppam,


Vanagaram, Chennai - 600 095 India
Tel:+91-44-24762594,+91-44-24764608 Fax: +91-44-24766920,
e-mail info@niceneotech.com Web: www.niceneotech.com