Is:800-1984
( Rerfflrmed 1998
                                                      ( Reaffirmed 2003) )
                   Indian Standard
            CODE OF PRACTICE FOR
                                                                             SUPPLIED BY BOOK SUPPLY BUREAU
                                                                             LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
        GENERAL CONSTRUCTION, IN STEEL
                 ( First Revision )
                   Sixtcmtb Reprint MAY WI!3
              (IncorporatingAmendments No. 1 and 2)
                        UDC 693814      : 006-76
                          8 Copyright 1995
        BUREAU       OF        INDIAN       STANDARDS
        MANAK BHAVAN, 9 BAHADUR SHAH ZAPAR MARG
                    NEW DELHI- 110002
Gr 15                                                   February, 1985
b
-
                                                                             18:soo-1981
                              Indian Standard
                 CODE OF PRACTICE FOR
             GENERAL CONSTRUCTION IN STEEL
                                                                                                      SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                      LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                            ( Second Revision)
              Structural Engineering Sectional Committee, SMBDC 7
            Chairman                                          Rejraanting
    DIREOTOBSTAHDAIGDS (Cm)                 Ministry of Railwaya
              Members
    SEBI R M. AGABWAL                   Institution of Engineers ( India ), Calcutta
        Da Pa=    ~ISEXA (Alimuf~ )
    SEEI 0. P. bA2?D                    Central Water Commission, New Delhi
        Srrnr V. NABAYANAEI ( Altmatr )
    Smt~ A. K. BANEEJ~B                     Metallurgical & Engineering Consultants ( India )
                                                Ltd, Ranchi
         Sass S. SANKlsAZ4 ( Alternate )
    SHRI P. G. BARDHAN                     Braithwaite & Co Ltd, Calcutta
         Srrnr S. K. GANQOPADHYAY ( Altarnets)
    SHBI S. N. BAEU                        Inspection Wing, Directorate General of Supplies
                                                & Disposals, New Delhi
         SHRI D. B. JAIN ( Affrrnafe )
    SHBT P. C. BHA+N                       Ministry of Shipping & Transport ( Department
                                                of Transport ) ( Roads Wing )
    DR P. DAYARATNAX                       Indian Institute of Technology,  Kanpur
     SHRI D. S. DESAI                      M. N. Dastur & Co Pvt Ltd, Calcutta
         SHRI S. R. KULKARNI ( Altmnutc )
    DIRECTOR ( TRANSMISSION )              Central Electricity Authority, New Delhi
          DEPUTY        DIREOTOR
            ( TRANSA~ISSION) ( AIturnata)
    JOINT DIREOTOR S T AN D A B D s Ministry of Railways
       (B&S)
         ASSISTANT     DIRECTOR
            STANDARDS   ( B & S )-SB ( Alternate )
    JOINT DIRECTOR ( DEBIONS )              National Building Organization,  New Delhi
         SERI K. S. SR~HIVASAN (Alternate )
                                                                            ( Continued on page 2 )
                                        0    Copyright 1995
                          BUREAU      OF      INDIAN     STANDARDS
      Thir publication   is protected under the Indian Copyright Act ( XIV of 1957 ) and
      reproduction in whole or in part by any meane except with written permissionof the
      publisher shall te deemed to be an infringement of copyright under the said'Act.            1
    l8:809-1984
    ( ,Co&inued from page 1 )
             Members                                      Ro@wnfing
    DR J. N. KAR                          Government of West Bengal
    SHRI KARTIK PRASAD                    Indian Roads Congress, New Delhi
        SRRI S. P. CHAKRABA~~~ ( Altsrnnfr )
                                                                                                  SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                  LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
    SHRI N. K. MAJUMDAB                    Hindustan    Steel    Works    Construction   Ltd,
                                               Calcutta
    SH~I P. K. MALLICK                    Jessop & Co Ltd, Calcutta
        SHRI T. S. BA~CHI ( AIfernufe )
    SHRI S. K. MUKEERJEE                   Bridge & Roof Co ( India ) Ltd, Howrah
        SHRI B. K. CHATTERJEE ( Alfernafe )
    SERI P. V. NAIK                      Richardson & Cruddas Ltd, Bombay
        SHRI V.-G. MANORULKAR ( Alfernnfe )
    SHRI DILIP PAVL                        Industrial   Fasteners   Association     of Indim
                                               Calcutta
i   SHRI H. C. PARYESWA~AN                Engineer-in-Chief’s  Branch, Army Headquarters
        SFIRI N. C. JAIN ( AItnnafr)
    SERI N., RADHAKRISH~AN                  Binny Ltd. Madras
        Sara1 P; APPARAO ( Alfekfe   )          .
    SHRI N. y. RADIAN                   , Struc$arax$gineering     Research Centre ( CSIR ),
        DR ‘ph’V. S. R. APP~ RAO ( Affernafe 1
    SHPI M. %:‘RANCSA   RAO                Tats Consulting Engineers, New Delhi
        SXRI~:A. S. BIJVRK AR ( Alternote )
    SH~I A. B. RIBE~O                     Rail    India  Technical   & Economic    Services,
                                               New Delhi
        SHRI S. K. BHANOT ( Alfcrnafe)
    SHRI P. SEN~UPTA                      Stewarts & Lloyds of India Ltd, C&utta
        SRRI M. M. GHO~H ( Alfemafe )
    SERI M. M. SHENOY                     Joint Plant Committee, Calcutta
        SBRI D. SRINIVASAN ( Alternate )
    SaxuC. N. SRINIVASAN                  Messrs C. R. Narayanan Rao, Madras
        SHRI Cl. N. RA~EAVENDRAN ( AIfcrnafe)
    SHRK M. SRIHARIVARDA RAJ              Bharat Heavy Electricals Ltd. Tiruchchirapalli
        SHRI A. K. MITTAL ( Alfernafe )
    S,ERI H.?K. TANEJA                     Indian Register of Shipping, Bombay
        SHR~ D. SARAN~DEAR ( Alfernafe )
    SEBI M:D. THAIUBEKAR                   Bombay Port Trust, Bombay
                                           University of Roorkee, Roorkee
                                           Engineers India Ltd, New Delhi
                                            Director General, BIS ( Ex-~&io Membrr )
                                              Secretary
                                           SERI S. S. SETHI
                                Deputy Director ( Strut & Met ), BIS
                                                                        ( Confinued on page 3 )
                                                  2
( Confinm#f*omPogr 2 )
             Subcommittee   for Use of Structural Steel in General
                    Building Constructim,     SMBDC 7 : 2
         Convener                                  Rethsettting
                                                                                     SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                     LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
SHRI A. CHELLAY                      Ministry of Railways
         Members
SHRI A. K. BAN~ZJX~                  Metallurgical & Engineering   Consultants ( India )
                                         Ltd. Ranchi
   SHRI S. SANKARAN( Alternate)
SHRI P. G. BARDHAN              Braithwaite & Co Ltd, Calcutta
   SHRI S. K. GAN~OPADEYAY ( Altanatr )
Da P. N. CHATTERJEE                 Bengal Engine&n      College, Howrah
SHRI S. K. DATTA                    Richardson & CN $ daa Ltd, Bombay
SHRI D. S. DESAI                    M. N. Dastur k Co Pvt Ltd, Calcutta
SHRI G. B. JAHA~IRDAR               The National Industrial Development       Corpora-
                                         tion Ltd, New Delhi
DR A. K. JAIN                        University of Roorkee, Roorkee
SHRI K. C. KARAMCHAF~ANI             Engineers India Ltd, New Delhi
    SHRI B. B. NAP ( Altcrnata )
Snnr P. K. MALLICK                    Jesrop & Co Ltd, Calcutta
SHRI P. R. NATARAJAN                   Structural Engineering Research Centre (CSIR),
                                           Madras
   DR T. V. S. R. A~PARAO     ( Alternate)
SHRI T. K. RAXANATHAN                 Triveni Structurals Ltd, Allahabad
   Snn~ M. N. PAUL ( Alternate )
SHRI Y. C. RAO                      The Tata Iron & Steel Co Ltd, Jamshedpur
    SHRI K. S. RANUANTHAN ( Aflernatc )
REPRESENTATIVE                      Engineer-in-Chief’s  Branch, Army Headquarters
REPRESENTATIVE                      Burn Standard Co Ltd, Howrah
S-1  P. R. BH~WMIO                  Steel Authority of India Ltd ( Bokaro       Steel
                                         PIant ), Bokaro Steel City
    SHRI N. K. CHAXRAVORTY ( Altcrnafs )
PROF P. K. SOM                      Government of West Bengal, Calcutta
SHRI C. N. SRINIVASAN               Meson C. R. Narayana Rao, Madras
SHRI K. VEERARAQHAVACHARY           Bharat Heavy Electricals Ltd, Tiruchchirapalli
    SHRI A. K. MITTAL ( Altcrnuts )
ISrsoo-MS4
                                  CONTENTS
                                                                                                  PALE
0. FOREWORD . . .          .. .         . ..       . ..     .. .    ...                             11
                                                                                                         SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                         LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                        SECTION         1       GENERAL
1.1 SC@qPE      ...   ...    ...    ...                     ...     ...                             13
1.2. TE~INOLOOY       ..,    ...     ...                    . ..    . ..                            13
1.3 !hfBOLS      ...   . ..  ...     ...                    . ..    ‘...                            14
1.4 REFERENCETO OTHER STANDARDS      ...                     . ..       *..                         17
1.5 UNITS AND CONVERSIONFACTORS     ...                     ...     ...                             20
1.6 STANDARDDIMENSIONS,FORM AND WEIGHT                      .. .        ...                         20
1.7 PLANS AND DRAWINGS. . .  ...     ...                    . ..    ...                             20
                        SECTION     2       MATERIALS
2.1 STRUCTURALSTEEL         ...          . ..      .. . .    l ..           ..I                     21
2.2 RIVETS      ...  ...                 ...        ...     ...         .           .         .
                                                                                                    21
2.3 WELDING CONSUMABLES                  ...        ...     ...             .         .       .
                                                                                                    21
2.4 STEEL CASTINGS  .:.                 . ..       ...      ...     .           .         .         22
2.5 BOLTS AND Nuts  ...                 ...        .. .     _.              .         .       .     22
2.6 WAsHERs   ...           ...         ...         ...     ...         .           .         .     22
2.7 CEMENTCONCRETE          ...         ...         _.      ...         .         .       .         22
2.8 OTHER MATERIALS         ...         ...         ...      ...        .           .         .     22
       SECTION      3    GENERAL DESIGN REQUIREMiNTS
3.1 TYPES OF LOADS          ...          ...         ...     ...                ...                 22
3.2 ERECTIONLOADS           ...    ...               ...     ...            ...                     23
3.3 TEMPERATUREEFFECTS             ...              ...      ...            ...                     23
3.4 DESIQN CONSIDERATIONS          ...              ...      ...            ...                     23
   3.4.1 General .__        ...    ...              ...      .. ,           ...                     23
   3.4.2 Load Combinations         ...              ...      ...            ...                     24
   3.4.3 Methods of Design         ...              ...      ...            ...                     25
   3.4.4 Simple Design      .. .   ...              ...      ...            ...                     25
   3.4.5 Semi-rigid Design         ...              ...      ...            ...                     25
   3.4.6 Fully Rigid Design        ...              ...      ...            ...                     25
   3.4.7 Experimentally Based Design                ...      . ..            .-.                    26
                                            4
                                                                                  1s I 900 - 19&4
                                                                                            PAQE
3.5 GEOMETRICAL    PROPERTIES              ............                                       26
   3.5.1 General ...       ...............                                                    26
   3.5.2 Plate Thickness  ...............                                                     27
3.6 HOLES          ......                  ............                                       28
                                                                                                   SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                   LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
   3.6.1 Diameter         ................                                                    28
   3.6.2 Deduction for Holes               ......                        ......               28
3.7 MAXIMUMSLENDERNESSRATIO .............                                                     30
3.8 CORROSIONPRoTEaTroN - MINIMUMTHICKNESSOF METAL                                            30
   3.8.1 General ..................                                                           30
   3.8.2 Steelwork Directly Exposed to. Weather        ......                                 30
   3.8.3 Steelwork Not Directly Exposed to Weather ......                                     30
   3.8.4 Rolled Steel.Be’ams and Channels    ......           ...                             31
3.9 INGREA~EOF STRESSES......                r........                                        31
   3.9.1 General ..................                                                           31
   3.9.2 Increase in Permissible Stresses in Members Proportioned
         for Occasional Loadings ............                                                 31
   3.9.3 Increase in Permissible Stresses for Design of Gantry
         Girders and Their Supporting Structures      ......                                  31
3.10 FLUCTUATIONOF STRESSES .............                                                     32
3.11 RESISTANCE   TO HORIZONTALFORCES ..........                                              33
3.12 STABILITY. ......               .........                 ...                            34
3.13 LIMITINO DIWLBCTION                      ............                                    34
3.14 EXPANSIONJOINTS .......                                 .........                        35
             SECTION        4    DESIGN OF TENSION                       MEMBERS
4.1 AXIAL STRE%¶           ...............                                                    37
4.2 DESIGNDETAILS           ......           .........                                        37
   4.2.1 Net Effective Areas for Angles and Tees in Tension                          ...      37
        SECTION         5   DESIGN OF COMPRESSION                            MEMBERS
5.1 IXXIALSTRESSES
                 IN UNCASED STRUTS    ...                                .......              38
5.2 EFFECTIVELEN~TI-IOF COMPRESSIONMEMBERS                                ...    ...          38
    5.2.1   General . . .    .,.     .,.                     ...          ...        ...      38
    5.2.2   Effective Length . . .    ...                    ...          ...        ...      40
    5.2.3   Eccentric Beam Connections                       ...          ...        . ..     40
    5.2.4   Members of Trusses       ...                     . ,,         ...        ...      40
    5.2.5   Stepped Columns          ...                     ...          . ..       ...      40
                                                                                                                                        ..
Is : 688 - 1984
                                                                          PAQE
5.3 DESIGNDETAILS           .. .      ...      ...      .. .      . ..      40
   5.3.1 Thickness of Elements        ,. .       ..     . ..      . ..      40
   5.3.2 Effective Sectional Area     _..      . ..     ...       ...       40
   5.3.3 Eccentricity for Stanchion   and Solid Columns           . ..      40
                                                                                  SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                  LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
   5.3.4 Splices . ..-      .. .      . ..     ...      . ..      .. .      43
5.4 COLUMNBASES             .. .      ...       ...     .. .      . ..       44
   5.4.1 Gusseted Bases    _..      .__    . ..          .. .     . ..       44
   5.4.2 Column and Base Plate Connections               ...      .. .       44
   5.4.3 Slab Bases       _..      _..     ...           . ..     . ..       44
   5.4.4 Base Plates and Bearing Plates    . ..          ...      . ..       46
5.5 ANISE STRUTS           _,_      _..      . ..          . ..   . ..       46
   5.5.1 Single Angle Struts       _..     .. .          ...      . ..       46
   5.5.2 Double Angie Struts       .__     ...           .. .     ...        46
   5.5.3 Continuous Members         _..     . ..          ...      ...       47
   5.5.4 Combined Stresses         _..      ...          . ..      . ..      47
5.6 STEEL CASTINGS         ___      ...     ...           ...      ...       47
5.7 LACING        ...       . ..  . ..          ...        . ..   ...        47
   5.7.1 General            . ..  ...           ...       . ..    ...        47
   5.7.2 Design of Lacing __.      ...          . ..      ...     ...        48
   5.7.3 Width of Lacing Bars      ...          ...       ...     . ..       50
   5.7.4 Thickness of Lacing Bars . . .         ...       ...     . ..       50
   5.7.5 Angle of Inclination     __.           . ..      .-.     . ..       51
   5.7.6 Spacing           ...    . ..          ...       ...     .. .       51
   5.7.7 Attachment to Main Members             ...       .. .    ...        51
   5.7.8 End Tie Plates     .._   ...           ...       ...     .. .       51
5.8 BATTENINGAND TIE PLATES . . .               ...
                                                  ...     . ..               51
   5.8.1 General           ...    .. .           .. .
                                                ...      . ..                51
   5.8.2 Design            . ..   ...             .. .
                                                ...      ...                 53
   5.8.3 Spacing of Battens       ...           ...
                                                 ...     ..i                 54
   5.8.4 Attachment to Main Members             .. .
                                                  ...    ..I
                                                                             54
5.9 COMPRESSIONMEMBERS COMPOSED OF         COMPONENTS
                                                   Two
     BACK-TO-BACK          ...    _..      . .. ...
                                                 ...                        54
                  SECTION 6 DESIGN OF MEMBERS
                      SUBJECT&D TO BENDING
6.1 GENERAL ...        ...      ...            ...       . ..     .n        55
6.2 BENDINGSTRESSES . . .       ...            .,.       . ..     ..,       55
   6.2.1 Maximum Bending Stresses              ...       . ..     . ..      55
                                       6
                                                         1s : 800 - 1984
                                                                                                                              PAGE
   6.2.2 Maximum Permissible Bending Compressive Stress in
         Beams and Channels with Equal Flanges    ...     . ..    55
   6.2.3 Maximum Permissible Bending Compressive Stress in
         Beams and Plate Girders . . .     ...    .,,     ...     56
                                                                                                                                    SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                                    LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
   6.2.4 Elastic Critical Stress  . ..     ...    ...      ...    63
   6.2.5 Beams Bent About the Axis of Minimum Strength (~9 Axis ) 68
   6.2.6 Angles and Tees . . .    . ..     ...    . ..     .. .   68
6.3 BEARINGSTRESS           . ..  . ..     ...    .. .     . ..   68
6.4 SHEARSTRESSES           .. .  .. .     ...    ..:     . ..    68
   6.4.1 Maximum Shear Stress     .,.      ...     . ..       I..
                                                                  68
   6.4.2 Average Shear Stress      . . .   . . .   . . .      .
                                                                  69              .                   .
6.5 EFFECTIVESPAN OF BEAMS        ...      ...     ...            76
                                                                  .               .                   .
6.6 EFFECTIVELENGTHOF COMPRESSION        FLANGES      . ..        .                   .                   .
                                                                                                                                   76
6.7 DESIGNOF BEAMSANDPLATE GIRDERSWITH SOLIDWEBS                  .                   .                   .
                                                                                                                                80
   6.7.1 Sectional Properties      . ..      ...       ...            .                   .                   .
                                                                                                                                80
   6.7.2 Flanges           . ..    ...       . ..      .f.        .                   .                   .
                                                                                                                                80
   6.7.3 Web Plates        ...     ...       ...       ...        .                   .                   .
                                                                                                                               .81
   6.7.4 Intermediate Web Stiffeners for Plate Girders                .                   .                   .
                                                                                                                                84
   6.7.5 Load Bearing Web Stiffeners         ...       ...                .                   .                   .
                                                                                                                                87
6.8 Box GIRDERS             . ..   . ..       .. .     .. .               .                   .                   .                88
6.9 PURLINS       “._      . ..    . ..      . . .     . ..               .a.
                                                                                                                                   89
6.10 SIDE ANDEND SHEETINGRAILS               .,.       . ..               a..
                                                                                                                                   89
              SECTION 7 COMBINED STRESSES
7.1 COMBINATIONOF DIRECT STRESSES        .. .      ..,                        .*.
                                                                                                                                   90
   7.1.1 Combined Axial Compression and Bending , . .                         .                   .                   .
                                                                                                                                   90
   7.J.2 Combined Axial Tension and Bending       . ..                    .                   .                       .
                                                                                                                                   90
   7.1.3 Symbols        . ..     ...     ...      ...                 .                   .                   .
                                                                                                                                   90
   7.1.4 Bending and Shear       ..      . ..     ...                     .                   .                   .
                                                                                                                                   91
   7.1.5 Combined, Bearing, Bending and Shear Stresses                            .                   .                   .        92
                   SECTION 8 CONNECTIONS
8.0 GENERAL . . .     ...    ...    . ..   . ..                               .                   .                   .        ’ 92
8.1 RIVETS, CLOSETOLERANCEBOLTS,HIQH STRENGTHFRICTION
    GRIP FASTENERS,BLACKBOLTSANDWELDING     ...   ._.                                                                              92
a.2 CO~~POSITECONNECTIONS    .,.    . . .   . . . .. .                                                                             92
8.3 MEMBERSMEETINGAT A JOINT        ...     ,..    . ..                                                                            93
                                                                                                                                                                                                                     .
IS t 888 - 1984
8.4 BEARINGBRACKETS . . .           ...      ...      .. .     ...    93
8.5 GussETs  ...     . ..  ...               ...      .. .     ...    93
8.6 PACKINGS . . .   . .,  . ..              . ..     . ..     ...    93
                                                                            SUPPLIED BY BOOK SUPPLY BUREAU
                                                                            LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
8.7 SEPARATORS
             AND DIAPHRAGMS._.               ...      . ..     .. .   94
8.8 LUG ANoLEs . . .  . ..    . ..   . ..             .*.      . ..   94
8.9 PERMISSIBLESTRESSES
                      IN RIVETSAND BOLTS              . ..     . ..   94
  8.9.1   Calculation of Stresses     ...     ...     ...      . ..   94
  8.9.2   Gross and Net Areas of Rivets and Bolts     ...      ...    95
  8.9.3   Areas of Rivets and Bolt Holes              . ..     ...    95
  8.9.4   Stresses in Rivets, Bolts and Welds 1::     ...      ...    95
8.10 RIVETS AND RIVETING            ...      . ..     . ..     . ..   96
   8.10.1 Pitch of Rivets . . .     ...      . ..     .. .     ...    96
   8.10.2 Edge Distance . . .       . ..     ...      ...      ...    97
   8.10.3 Tacking Rivets . . .      . ..     ...      . ..     .. .   97
   8.10.4 Countersunk Heads         ...      . ..     .. .     . ..   98
   8.10.5 Long Grip Rivets          ...      ...      ...      ...    ?8
8.11 BOLTSAND BOLTING . . .         ...      . ..     ...      . ..   98
   8.11.1 Pitches, Edge Distances for Tacking Bolts   . ..     .. .   98
   8.11.2 Black Bolts     ...       ...      ...      ...      .. .   98
   8.11.3 Close Tolerance Bolts     ...      ...      . ..     ...    98
   8.11.4 Turned Barrel Bolts        ...     ...      . ..     ...    98
   8.11.5 ‘Washers         .. .     ...      ...      ...      .. .   98
   8.11.6 Locking of Nuts . . .     ...      ...      ...      .. .   98
8.12 WELDSAND WELDING                ...     ...      . ..     ...    98
                   SECTION 9 PLASTIC DESIGN
9.1 GENERAL        .. .   .,.     ...        ...       ...     . ..   99
9.2 DESIGN         .. .   ..,    ...         ...       ...     ...    99
   9.2.1 Load Factors     .. .   ...         ...       ...     ...    99
   9.2.2 Deflection       ...    ...         ...       ...     .. .   99
   9.2.3 Beams            ...    ...         ...       ...     ...    99
   9.2.4 Tension Members         ...         ...       ...     ...    ioo
   9.2.5 Struts    .. .   ...    .*.         ...       ...     . ..   100
   9.2.6 Members Subjected to Combined         Bending, and   Al&d
         Forces ( Beam-Column Members )      . ..      ._       ...   100
   9.2.7 Shear . . .     ...    .. .        ...        . ..    . ..   101
                                      8
                                                                                  PAQE
   9.2.8 Stability.. .............                                         .. .    101
   9.2.9 Minimum Thiekneas                      .........                  . ..    102
   9.2.10 Lateral Bracing         ...........                        ...   . ..    103
                                                                                          SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                          LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
   9.2.11 Web Stiffening ...                    ._          ......         A..     104
   9.2.12 Load Capacitiesof Connections                     ......         . ..    105
9.3 CONNECTIONS     ANDFABRICATION                          ......         ...     105
   9.3.1 Connections               ............                            ...     105
   9.3.2 Fabrication               ............                            ...     105
            SECTION 10 DESIGN OF ENCASED MEMBERS
10.1 ENCASEDCOLUMNS ...............                                                 105
   10.1 .l Conditions of Design     .............                                   105
   10.1.2 Design of Member          ............                                    106
10.2 ENCASED   BEAMS       ...      1..           .........                         107
   10.2.1 Conditions of Design      ............                                    107
   10.2.2 Design of Member          ............                                    107
             SECTION 11 FABRICATION AND ERECTION
11.1 GENERAL ..................                                                     108
11.2 FABRICATION  PROCEDURIS ............                                           108
   11.2.1 Straightening ...............                                             108
   11.2.2 Clearances             ...............                                    108
   11.2.3 Cutting                ...............                                    108
   11.2.4 Holing ..................                                                 108
11.3 &SEMBLY ...............                                                _.      109
11.4 RIVETING ..................                                                    109
 11.5 BOLTING ..................                                                    110
 11.6 WELDING ................                                              ...     110
 11.7 MACHININQOFBUTTS,CAPSANDBASES.........                                        110
 11.8 SOLIDROUNDSTEELCOLUMNS        .........                                       111
 11.9 BArNTrNo ..................                                                   111
 11.10 MARKING..................                                                    112
 11.11 SHOPERECTION ...............                                                 112
 11.12 PACKING ..................                                                   112
                ANDTESTLNO ............
 11.13 INSPECTION                                                                   112
                                                  9
IS t 800- 1984
                                                                  PAGE
11.14 SITE ERECTION        ...      ...    ...    . ..    ...      113
   11.14.1 Plant and Equipment      ...    ...    ...     .. .     113
   11.14.2 Storing and Handling     ,..    . ..   ...     . ..     113
                                                                          SUPPLIED BY BOOK SUPPLY BUREAU
                                                                          LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
   il.14.3  Setting Out     ...     ...    ...    ...     *..      113
   11.14.4 Security During Erection        ...    ...     ...      113
   Il. 14.5 Field Connections       ...    ...    ...     ...      114
11.15 PAINTING AFTER ERECTION . . .        .. .   . ..    . ..     114
11.16 BEDDING OF STANCHION BASES AND BEARINGS OF BEAMS AND
      GIRDERS ON STONE, BRICK OR CONCRETE ( PLAIN OR
      REINFORCED  )    ...     .. .    .. .    ...     ...         114
               SECTION ii STEELWORK TENDERS
                      AND CONTRACTS
12.1 GENERAL RECOMMENDATIONS                                        115
                             APPENDICES
APPENDIX A CHART SHOWING HIGHEST MAXIMUM TEMPERATURE                116
APPENDIX B CHART SHOWING LOWEST MINIMUM TEMPERATURE                 117
APPENDIX C EFFECTIVE LENGTH OF COLUMNS             . ..    . ..     118
APPENDIX D METHOD FOR DETERMINING EFFECTIVE LENGTH FOR
           STEPPED COLUMNS    .. .    .. .   ,..   ...              120
APPENDIX E .LIST OF REFERENCES ON THE ELASTIC FLEXURAL
           TORSIONAL BUCKLING OF STEEL BEAMS . . . .. .             131
APPENDIX F PLASTIC PROPERTIES OF INDIAN STANDARD MEDIUM
           WEIGHT BEAMS [ IS : 808 ( Part 1 )-I973 } ...            132
APPENDIX   G   GENERAL   RECOMMENDATIONS FOR        STEELWORK
               TENDERS AND CONTRACTS   ...         .. .   . ..      133
                                      10
                                                            ISt800-1984
                       Indian Standard
              CODE OF PRACTICE FOR
         GENERAL CONSTRUCTION IN STEEL
                                                                               SUPPLIED BY BOOK SUPPLY BUREAU
                                                                               LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                      ( Second Revision )
                        0.   FOREWORD
0.1 This Indian Standard ( Second Revision) was adopted by the Indian
Standards Institution on 25 April 1984, after the draft finalized by the
Structural Engineering Sectional Committee had been approved by the
Structural and Metal Division Council and the Civil Engineering Division
couucil.
0.2 The Steel Economy Programme was initiatedbyIS1 in 1950’s with the
object of achieving economy in the use of structural steel by establishing
rational, efficient and optimum standards for structural steel products and
their use. IS : 800-1956 was the first in the series of Indian Standards
brought out under this programme.      The revision of this standard was
taken up after the standard was in use .for some time which was published
in 1962 incorporating certain very important changes.
0.3 IS : 800 is a basic standard widely used and accepted by engineers,
technical institutions, professional bodies and the industry. The committee
while preparing the second revision has given careful consideration tb the
comments received on the standard during its usage. Consideration has also
been given to the developments taking place in the country and abroad;
necessary modifications and additions have therefore been incorporated to
make the standard more useful.
0.4 In this revision the following major modifications have been effected:
     a>Besides a general rearrangement of the clauses,
       values have been given’in SI units only.
                                                          formulae and the
     b)   Symbols used in this standard have been aligned to the extent
          possible with IS0 3898-1976 ‘ Basis for design of structures -
          Notation - General symbols ‘, and these have been listed in 1.3.
     4    All the Indian Standards referred to in this Code have been listed
          under 1.4.
                                     11
1s t 800 - 1984
      d)   In view of the development and production of new varieties of
           medium and high tensile structural steels in the country, the
           scope of the Code has been modified permitting the use of any
           variety of structural steel provided the relevant provisions of the
           Code are satisfied.
                                                                                 SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                 LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
      e>Indian Standards are now available for rivets, bolts and other
         fasteners and reference has been made to these standards.
      f >In view of the fact that the Code specifies a number of grades of
           steel with different yield strengths, the design parameter, the
           geometrical properties and permissible stresses have been express-
           ed to the extent possible in terms of the yield strength of the
           material.    Specific values have also been given for commonly
           used steels.
      g)   Recommendations regarding expansion joints have been added.
      h)   Keeping in view the developments in the design of steel struc-
           tures there has been a general revision in the permissible stress
           values for steels and fasteners.
      j> In    IS : 800-1962, design by plastic theory had been permitted. In
           this revision detailed design rules have been included for design
           using plastic theory.
     k) Specific provisions relating to limiting deflection have been
        added.
     m) Effective length of columns has been dealt with in a greater
        detail. For normally encountered struts, a table has been given
        strictly on the basis of end conditions. The effective length of
        columns in framed structures and stepped columns in mill build-
        ings have been specified on more exact basis.
     4     The secant formula for axial compression has been dropped.  In
           its place the Merchant Rankine formula has been specified with
           value of a, empirically fixed as 1.4.
     P) Bending stresses - The method of calculating the critical stresses
        in bending compression f,,b has been simplified by expressing the
        formulae in terms of geometrical properdes of the section.
        Merchant Rankine formula recommended for calculating permis-
        sible stresses in axial compression has been used for calculating
        permissible stresses in bending compression from the critical
        stresses, with value of n, empirically fixed as l-4.
   0.4.1 More rigorous analytical procedures than envisaged in this Code
are available and can be made use of for finding effective lengths of com-
pression members in determining elastic critical loads.
0.5 The original tide of the code namely ‘Code of practice for use of
structural steel in general building construction ’ has now been modified as
                                      12
( Code of practice for general construction in steel ‘, since it was felt that
the code is applicable to all types of steel structures and not limited to
buildings only.
0.6 While preparing this Code, the practices prevailing in the field in the
country have been kept in view. Assistance has also been derived from the
                                                                                   SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                   LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
following publications:
      AS 1258-1981 SAA Steel structures code. Standards Association of
          Australia.
      RS 449 ( Part II )-1969   Specification for I the use of structural
          steel in building; Part II Metric units. British Standards
          Institution.
      AISC Specification for the design, fabrication and erection of
          structural steel for buildings. American Institute of Steel
          Construction.
      SNIP-II-W-72  Code of Practice for design of steel structures of the
          USSR State Committee for Construction.
                          SECTiON 1 GENERAL
1.1 Scope
   1.1.1 This code applies to general construction in steel. Specific provisions
for bridges, chimneys, cranes, tanks, transmission line towers, storage
structures, tubular structures and structures using cold formed light gauge
sections, etc, are covered in separate codes.
  1.1.2 The provisions of this code generally .apply to riveted, bolted and
welded constructions, using hot rolled steel sections.
   1.1.3 This code gives only general guidance as regards the various loads
to be considered in design , For actual loads to be used reference may be
made to IS : 875-1964.
1.2 Termino@gy       -   For the purpose of this code the following detini-
tions shall apply.
  1.2.1 Buckling Load - The load at which a member or a structure as a
whole collapses in service or buckles in a load test.,
   1.2.2 Dead Loads - The self weights of all permanent constructions and
installations including the self weights of all walls, partitions, floors ana
roofs.
                                       13
IS r&lo-1904
   1.2.3 Effective Lateral Restraint - Restraint which    reduces sufficient
resistance in a plane perpendicular to the plane of ben Bing to restrain the
compression flange of a loaded strut, beam or girder from buckling to either
side at the point of application of the restraint.
                                                                                    SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                    LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
   1.2.4 Elastic Critical Moment -    The elastic moment which will initiate
yielding or cause buckling.
  1.2.5 Factor of Safety - The factor by which the yield stress of the
material of a member is divided to arrive at the permissible stress in the
material.
   1.2.6 Gauge -   The transverse     spacing between parallel adjacent     lines
of fasteners.
   1.2.7 Imposed ( Live ) Load - The load assumed to be produced by the
intended use of occupancy including distributed, concentrated, impact and
vibration and snow loads but excluding, wind and earthquake loads.
    1.2.8 Load Factor - The numerical factor by which the working load
is to be multiplied to obtain an appropriate design ultimate load.
   1.2.9 Main Member - A structural member which is primarily responsi-
ble for carrying and distributing the applied load.
    1.2.10 Pitch - The centre        to   centre   distance- between   individual
fasteners in a line of fastener.
   1.2.11 Secondary Member - Secondary member is that which is provided
for stability and or restraining the main members from buckling or similar
modes of failure.
  1.2.12 Welding Terms - Unless otherwise defined in this standard the
welding terms used shall have the meaning given in IS : 8121957.
   1.2.13 Yield Stress - The minimum yield stress of the material in tension
as specified in relevant Indian Standards.
1.3 Symbols - Symbols used in this Code shall have the following mean-
ings with respect to the structure or member or condition, unless other-
wise defined elsewhere in this Code:
A          Cross-sectional area ( A used with subscripts has been defined at
             appropriate place )
4, b       Respectively the greater and lesser projection of the plate beyond
             column
B          Length of side ofcap      or base
be         Width of steel flange in encased member
c,         Coefficient
                                          14
-
    c         The distance centre to centre of battens
    c         Distance between vertical stiffeners
    Cl, ca    Respectively the lesser and greater distances from the sections
                neutral axis to the extreme fibres
                                                                                  SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                  LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
    D         Overall depth of beam
    d         De th of girder - to be taken as the clear distance between
                i ange angles or where there are no flange angles the clear
                distance between flanges ignoring fillets
    to:       Diameter of the reduced end of the column
    4         i) For the web of a beam without horizontal stiffeners-the clear
                 distance between the flanges, neglecting fillets or the clear
                 distance between the inner toes of the flange angles as aipro-
                 priate.
              ii) For the web of a beam with horizontal stiffeners - the clear
                 distance between the horizontal stiffener and the tension
                 flange, neglecting fillets or the inner toes of the tension flange
                 angles as appropriate.
    da        Twice the clear distance from the neutral axis of a beam to the,
                 compression flange, neglecting fillets or the inner toes of the
                 flange angles as appropriate
    E         The modulus of elasticity for steel, taken as 2 x 10” MPa in this
                Code
    fY        Yield stress
    f ob      Elastic critical stress in bending
    foo       Elastic critical stress in compression,    also   known    as   Euler
                critical stress.
              Gauge
    f         Outstand of the stiffener
    I        Moment of inertia
    Kb or x0 Flexural stiffnesscs
    kl, ks   Coefficients
    k         Distance from outer face of flange to web toe of fillet of member
                to be stiffened
    L         Span/length of member
    1         Effective length of the member
    M         Bending moment
    M,        Maximum moment ( plastic ) capacity of a section
    MD0       Maximum moment ( plastic ) capacity of a section subjected to
               bending and axial loads
                                         15
Lateral buckling strength in the absence of axial load
Number of parallel planes of battens
Coefficient in the Merchant       Rankine formula, assumed as I.4
Axial force, compressive or tensile
Calculated maximum load capacity of a strut
                                                                          SUPPLIED BY BOOK SUPPLY BUREAU
                                                                          LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
Calculated maximum load capacity as a tension member
Euler load
Yield strength of axially loaded section
The reaction of the beam at the support
Radius of gyration of the section
Transverse distance      between    centroids   of rivets   groups   or
   welding
Staggered pitch
Mean thickness of compression flange ( T used with subscripts
 has been defined at appropriate place )
Thickness of web
Transverse shear
Longitudinal shear
Calculated maximum shear capacity of a section
Total load
Pressure or loading on the underside of the base
Plaqtic modulus of the section
Ratio of smaller to larger moment
Stiffness ratio
Slenderness ratio of the member; ratio of the effective length ( I)
   to the appropriate radius of gyration (Y)
Characteristic   slenderness ratio =!?
                                Al- p,
Maximum permissible compressive stress in an axially loaded
 strut not subjected to bending
Maximum permissible tensile stress in an axially loaded tension
 member not subjected to bending
Maximum permissible bending stress in slab base
Maximum permissible compressive stress due to bending in a
  member not subjected to axial-force.
Maximum permissible tensile stress due to bending in a member
  not subjected to axial force
                             16      --
                                                                                                                                                           .
h
                                                                                 lS:doo-    198
        CO           Maximum permissible stress in concrete in compression
        Qe           Maximum permissible equivalent stress
        UP           Maximum permissible bearing stress in a member
     =Pf             Maximum      permissible bearing stress in a fastener
     QIlo            Maximum permissible stress in steel in compression
                                                                                                   SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                   LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
     =ti            Maximum permissible stress in axial tension in fastener
     uaoc,
        081.         Calculated average axial compressive stress
     Qat,t,oal.      Calculated average stress in a member due to an axial tensile
                       force
    flbbo, 081.     Calculated compressive stress in a member due to bending about
                      a principal axis
    cbt> oal.       Calculated tensile stress in a member due to bending about both
                      principal axes
    +a              Maximum permissible average shear stress in a member
    Grn             Maximum permissible shear stress in a member
    Gf              Maximum permissible shear stress in fastener
    e               Ratio of the rotation at the hinge point to the relative elastic
                      rotation of the far end of the beam segment containing plastic
                      hinge
    V               Coefficient
    I               Ratio of total area of both the flanges at the point of least bend-
                      ing moment to the corresponding’area ar’the point of greatest
                      bending moment
    0               Ratio of moment of inertia of the compression flange alone to
                      that of the sum of the moments of inertia of the flanges each
                      calculated about its own axis parallel to the _Y=Yaxis of the
                      girder, at the point of maximum bending moment.
              NOTE- The aubscri t x, y denote        the x-x and r-y axes of the section respec-
         tively.    For symmetrica P aectioos,   x-x denotes the majot principal axti whilrty-y
         denotes   the minor principal axis.
    1.4 Reference to Other Strmddads - All the standards referred to in
    this Code are listed as under; and their latest versickshall be applicable:
    IS :
    226-1975       Structural steel ( standard quality ) (#“A rcvijion )
    456-1978       Code of practice for plain and reinforced concrete ( fhirdrevision )
    696-1972       Code of practice       for    general   engineering     drawings     ( second
                   rmision )
*u.
      IS : 800 - 1984
      IS :
       786-1967     ( Supplement ) SI supplement to Indian Standard conversion
                     factors and conversion tables (Jrst rcrji&ti\)
       812-1957     Glossary of terms relating to welding and cutting of metals
       813-1961      Scheme of symbols for welding
                                                                                           SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                           LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
       814 Covered electrodes for metal arc welding of structural steels:
         ) 814 ( Part 1 )-1974    Part 1 For welding products other than sheets
                   (fourth revision )
             814 ( Part 2 )-1974    Part 2 For welding sheets (jwth          revision )
       816-196~     Code of practice for use of metal arc welding for general
                    construction in mild steel (first revision )
       817-1966     Code of practice for training and testing of metal arc welders
                    ( Y&Cd)
       819:1957     Code of practice for resistance spot welding for light assemb-
                    lies in mild steel
       875-1964     Code of practice for structural safety of buildings: Loading
                    standards ( rem>ed)
       919-1963      Recommendations      for limits and fits for engineering (revised )
       961-1975      Structural steel ( high tensile ) ( second revision )
       962- 1,967   Code of practice for architectural     and building drawings (first
                    revision )
      1024-1979      Code of practice for use of welding in bridges and structures
                     snbjec t to dynamic loading (Jrst revision )
      1030-1982     ‘Carbon steel castings for general engineering purposes ( second
                     revision )
      1148-1973     Hot-rolled steel rivet bars ( up to 40 mm diameter ) for struc-
                    tural purposes ( second revision )
      1149-1982     High tensile steel rivet bars for structural purposes
      1261-1959     Code of practice for seam welding in mild steel
      12781372      Filler rods and wires fo.r gas welding ( second revision )
      1323-1962     Code of practice for oxy-acetylene welding for structural work
                    in mild steel ( revised )
      1363-1967     Black hexagon bolts, nuts and lock nuts ( diameter 6 to
                     39 mm ) and black hexagon screws ( diameter 6 to 24 mm )
                    .( @t~w.dsion )
      1364-1967     Preia)iv; and semi-precision hexagon bolts, screws, nuts and
                    lo+c,nq~     diameter range 6 to 39 mm ) (Jirst revision )
                                               18
                                                                                                                                                                            .
                                                                   IS:     8901.1984
IS :
1367-1967     Technical supply conditions for threaded fasteners           ( jirst rwi-
              sion )
1393-1961     Code of practice    for training     and testing of oxy-acetylene
              welders
1395-1971     Molybdenum a$         ehro%ium molybdenum       vanad’       lov
                                                                                          SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                          LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
              alloy steel electrodes for metal arc welding ( third r&jT nh))
1477     Code of practice fodpainting of ferrous metals in buildings:
       1477 ( Part 1 )-1971 Part 1 Pretreatment ( jirst r&.&n )
    1477 ( Part 2 )-I971 Part 2 Painting
1893-1975 Criteria for earthquake resistant design of structures ( third
            revision )
1929-1961     Rivets for/general purposes ( 12 to 48 mm diameter )
1977-1975     Structural steel ( ordinary qua&y     ) ( secondrevision )
2062- 1984    Weld&\ “structural steel ( third revision )
2155-1962     Rivets t r general purposes (below 12 mm diameter )
36131974      Accep+nce tests for wire-flux combinations for submerged-arc
              welding of structural steels ( jirst m&ion )
3640-1967     Hexagon fit bolts
3757-1972     High-tensile friction grip bolts (jirst mixion )
4000-l 967    Code of practice for assembly of structural joints using high
              tensile friction grip fasteners
5369-1975     General requirements for plain washers and lock washers
               ( jirst revision )
5370-1969     Plain washers with outside diameter 3 x inside diameter
5372-1975     Taper washers for channels ( ISMC ) (first revision )
5374-1975     Taper washers for I-beams ( ISMB ) (first r&on         )
6419-1971     Welding rods and bare electrodes for gas shielded arc welding
              of structural steel
6560-1972     Molybdenum    and chromium-molybdenum              low alloy steel
              welding   rods and base electrodes for           gas shielded arc,
              weIding ’                                                  /
6610-1972    Heavy washers for steel structures
6623-1972    High tensile friction grip nuts
6639-1972     Hexagon bolts for steel structures
6649-1972     High tensile friction grip washers.
                                       19
 IS t 888 - 1984
 7205-1973   Safety code for erection of structural steel work
 7215-1974   Tolerances for fabrication of steel structures
 7280-1974   Bare wire electrodes for submerged arc welding of structural
             steels
 7807 ( Part 1 )-1974 Approval tests for welding procedures: Part 1 Fusion
             welding of steel
                                                                               SUPPLIED BY BOOK SUPPLY BUREAU
                                                                               LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
 7818 ( Part 1 )-1974 Approval tests for welders working to approved
             welding procedures: Part 1 Fusion welding of steel
 7318 (Part 1 )-1974 Approval tests for weldersswhen welding procedure
             is not required: Part 1 Fusion welding of steel
 8500-1977   Weldable structural steel ( medium and high strength quali-
             ties )
 9595-1980   Recommendations for metal arc welding of carbon and carbon
             manganese steels
13 Units and Conversion Factors - The SI system of units is appfi-
cable to this code. For conversion of system of units to another system,
IS : 786-1967 ( supplement ) may be referred.
1.6 Standard Dimensions,       Form and Weight
   1.6.1 The dimensions, form, weight, tolerances of all rolled shapes and
other members used in any steel structure shall, wherever available
conform to .the appropriate Indian Standards.
   1.6.2 The dimensions, form, weight, tolerances of all rivets, bolts,
nuts, studs, etc, shall conform to the requirements of appropriate Indian
Standards, wherever available.
1.7 Plans and Drawings
   1.7.1 Plans, drawings and stress sheet shall be prepared according to
IS : 696-1972 and IS ,: 962-1967.
       1.7.1.1 Plans - The plans ( design drawings ) !hall show the com-
plete design with sixes, sections, and the relative locaticns of the various
members. Floor levels, column centres, and offsets shall be dimensioned.
Plans shall be drawn to a scale large enough to convey the information
adequately,    Plans shall indicate the type of construction to be employed;
and shall be supplemented by such data on the assumed loads, shears,
moments and axial forces to be resisted by all members and their connec-
tions, as may be required for the proper preparation of shop drawings.
Any special precaution to be taken En the erection of structure from the
design consideration, the same shall also be indicated in the drawing.
                                     20
                                                               IS : 808 - 1984
      1.7.1.2 Shop drawings - Shop drawings, giving complete information
necessary for the fabrication of the component parts of the structure in-
cluding the location, type, size, length and detail of all welds, shall be
prepared in advance of the actual fabrication. They shall clearly distinguish
between shop and field rivets, bolts and welds. For additional information
                                                                                 SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                 LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
to be included on drawings for designs based on the use of welding, refer-
ence shall be made to appropriate Indian Standards. Shop drawings shall
be made in conformity with IS : 696-1972 and IS : 962-1967. A marking
diagram allotting distinct identification marks to each separate part of
steel work shall be prepared. The diagram shall be sufficient to ensure
convenient assembly and erection at site,
   1.7.2 Symbols for welding used on plans and shop drawings          shall be
according to IS : 813-1961.
                      SECTION      2   MATERIALS
2.1 Structural   Steel - All structural steels used in general construction
coming under the purview of this code shall, before fabrication conform to
IS : 226-1975,. IS : 961-1975,  IS : 1977-1975,   IS : 2062-1984, and IS:
8500-1977 as appropriate.
   3.1.1 Any structural steel other than those specified in 2.1 may also be
used provided that the permissible stresses and other design provisions are
suitably modified and the steel is also suitable for the type of fabrication
adopted.
2.2 Rivets - Rivets shall conform to IS : 1929-1961      and IS : 2155-1962
as appropriate.
   2.2.1 High Tensile Steel Rivets - High tensile steel rivets, if used, shall
be manufactured from steel conforming to IS : 1149-1982.
2.3 Welding      Consumables
   2.3.1 Covered electrodes shall conform to IS: 814          ( Part 1 )-1974,
IS : 814 ( Part 2 )-1974 or IS : 1395-1971 as appropriate.
  2.3.2   Filler rods and wires for gas welding shall conform to IS : 12?8-
1972.
   2.3.3 The bare wire electrodes for submerged-arc welding shall con-
form to IS : 7280-1974. The combination of wire and flux shall satisfy the
requirements of IS : 3613-1974.
   2.3.4 Filler rods and bare electrodes for gas shielded metal arc welding
shall conform to IS : 641941971 and IS : 6560-1972 as appropriate.
                                       21
     Is t 888 - 1984
     2.4 Steel    Cast&s          -   Steel castings shall conform to grade 23-45    of
     IS:   103011982,”
     2.5 Bolts and‘hhtts -_ Bolts and nuts shall co orm to IS:             1363-1967,
     IS: 1364-1967, IS: 1367-1967, IS: 3640-1967, I $ : 3757-1972,         IS : 6623-
     1972, and IS :‘6639-19i2 as appropriate.
                                                                                          SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                          LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
     2.6 Washers -‘Washers   shall conform to IS : 5369-1975, IS : 5370-1969,
     IS: 5372-1975, IS: 5374-1975,   IS: 6610-1972,  and IS: 6649-1972 as
     appropriate.
    . 2,7 Cement Concrete - Cement concrete used in association with struc-
;     tural steel shall comply with the appropriate provisions of IS : 456-1978.
     .2.8 Other Materials      - Other materials used in association with struc-
      tural steel work shall conform to appropriate Indian Standards.
               SECTION            3   GENERAL DESIGN REQUIREMENTS
      3.1 Types        of Loads
         3.1.1 For the purpose of computing the maximum stresses in any struc-
      ture or member of a structure, the following loads and load effects shall be
      taken into account, where applicable:
                 Dead loads;
                 Imposed loads;
                 Wind loads;
                 Earthquake loads;
                 Erection loads; and
                 Secondary effects due to contraction or expansion resulting from
                 temperature changes, shrinkage, creep in compression members,
                 differential settlements of the structure as a whole and its com-
                 ponents.
            3.1,l.l Dead loads, imposed loads and wind loads to be assttmed in
      design shall be as specified in IS : 875-1964.
            3.1.1.2 Imposed loads arising from equipment, such as cranes, and
      machiDes to be assumed in design shall be as per manufacturers/suppliers
      data ( see 3.4.2.4 ).
             3.1.1.3     Earthquake loads shall be assumed as per. IS : 1893-1975.
            3.1.1.4 The erection loads and temperature effects shall be considered
      as specified in 3.2 and 3.3.
                                                             IS : 800 - 1984
3.2 Erection Loads
   3.2.1 All loads required to be carried by the structure or any part of it
due to storage or positioning of construction material and erection equip-
ment including all loads due to operation of such equipment, shall be
considered as ‘ erection loads ‘. Proper provision shall be made, including
                                                                           SUPPLIED BY BOOK SUPPLY BUREAU
                                                                           LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
temporary bracings to take care of all stresses due to erection loads. The
structure as a whole and all parts of the structure in conjuction with the
temporary bracings shall be capable of sustaining these erection lo tds,
without exceeding the permissible stresses as specified in this code sub_fect
to the allowable increase of stresses as indicated in 3.9. Dead load, wind
load and also such parts of the live load as would be imposed on the struc-
ture during the period of erection shall be taken as acting together with the
erection loads.
3.3 Temperature     Effects
   3.3.1 Expansion and contraction due to changes in temperature of the
materials of a structure shall be considered and adequate provision made
for the effects produced.
   3.3.2 The temperature range varies for different localities and under
different diurnal and seasonal conditions.      The absolute maximum and
minimum temperatures which may be expected in different localities in
the country are indicated on the maps of India in Appendices A and B,
respectively.  These appendices may be used for guidance in assessing the
maximum variations of temperature for which provision for expansion and
contraction has to be allowed in the structure.
   3.3.3 The temperatures indicated on the maps in Appendices A and B
are the air temperatures in the shade. The range of variation in tempera-
ture of the building materials may be appreciably greater or less than the
variation of air temperature and is influenced by the condition of exposure
and the rate at which the materials composing the structure, absorb or
radiate heat. This difference in temperature variations of the material and
air should be given due consideration.
   3.3.4 The co-efficient of expansion for steel shall be taken ‘as 0.000 012
per degree centigrade per unit length.
3.4 Design Considerations
    3.4.1 General - All parts of the steel framework’ of the structure shall
 be capable of sustaining the most adverse combination of the dead loads,
‘prescribed imposed loads, wind loads, earthquake loads where ,applicfble
 and any other forces or loads to which the ,building may reasonably be
 subjected without exceeding the permissible stresses specified in, this
 standard.
                                     23
ISr8oo-1984
  3.4.2   Load Combinations
      3.4.2.1 Load combinations for design purposes shall be the one that
produces maximum forces and effects and consequently maximum stresses
from the following combinations of loads:
      a) Dead load + imposed loads,
                                                                                                   SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                   LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
      b) Dead load + imposed loads + wind or earthquake loads, and
       c) Dead load + wind or earthquake loads.
       NoTe - In case of structures bearing   crane   loads,   imposed    loads shall   include
   the crane effect as given in 3.4.2.4.
      3.4.2.2 Wind load and earthquake loads shall be assumed not to
act simultaneously. The effect of both the forces shall be given separately.
       3.4.2.3 The effect of cranes to be considered under imposed loads
shall include the vertical loads, eccentricity effects induced by the vertical
loads, impact factors, lateral ( surge ) and the longitudinal horizontal
thrusts acting across and along the crane rail, respectively.
      3.4.2.4 The crane loads to be considered shall be as indicated by the
customer. In the absence of any specific indications the load combination
shall be as follows:
       a) Vertical loads with full impact from one loaded crane or two
          cranes in case of tandem operation together with vertical loads,
          without impact, from as many loaded cranes as may be positioned
          for maximum effect, alongwith maximum horizontal thrust
          ( surge ) from one crane only or two cranes in case of tandem
          operation;
       b) For multibay multicrane gantries - loads as specified in (a) above,
          subject to consideration of cranes in maximum of any two bays of
          the building cross section;
       Cl The longitudinal thrust on a crane track rail shall be considered
          for a maximum of two loaded cranes on the track; and
       4 Lateral thrust ( surge ) and the longitudinal thrust acting respect
          tively across and along the crane rail shall not be assumed to act
          simultaneously.    The effect of both the forces, shall, however, be
          investigated separately.
      3.4.2.5 While investigating the effect of earthquake forces the result-
ing effect from dead loads of all cranes parked in each bay positioned for
maximum effect shall be considered.
      3.4.2.6 The crane runway girders                supporting         bumpers    shall     be
checked for bumper impact loads.
                                         24
                                                                 IS : 800 - 1984
       3.4.2.7 Stresses developed due to secondary effects such as handling,
erection,     temperature   effects, settlement   of foundations    shall be
appropriately added to the stresses calculated from the combination of
loads stated in 3.4.2.1.   The total stresses thus calculated shall be within
the permissible limits as specified in 3.9.
                                                                                SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
   3.4.3 Methods of Design - The following methods may be employed for
the design of the steel framework:
         a) Simple design,
         b) Semi-rigid design, and
         c) Fully rigid design.
   3.4.4 Simple Design - This method applies to structures in which the
end connections between members are such that they will not develop
restraint moments adversely affecting the members and the structure as a
whole and in consequence the structure may, for the purpose of design, be
assumed to be pin-jointed.
         3.4.4.1   The method of simple design involves the following    assump-
tions:
         a) Beams are simply supported;
         b) All connections of beams, girders or trusses are virtually flexible
            and are proportioned for the reaction shears applied at the
            appropriate eccentricity;
         c) Members in compression       are subjected to forces applied at the
            appropriate eccentricities   ( see 5.3.3 ) with the effective length
            given in 5.2; and
         d) Members in tension are subjected to longitudinal forces applied
            over the net area of the section, as specified under 3.6.2 and 4.2.1.
   3.4.5 Semi-Rigid Design - This method, as compared with the simple
design method, permits a reduction in the maximum bending moment in
beams suitably connected to their supports, so as to provide a degree of
direction fixity, and in the case of triangulated frames, it permits account
being taken of the rigidity of the connections and the moment of interaction
of members. In cases where this method of design is employed, calculations
based on general or particular experimental evidence shall be made to show
that the stresses in any part of the structureare not in excess of those laid
 down in the code. Stress investigations may also be done on the finished
structure for assurance that the actual stresses under specific design loads
are not in excess of those laid down in the standard.
    3.4.6 Fully Rigid Design - This method as compared to the methods of
 simple and semi-rigid designs gives the greatest rigidity and economy in
                                         25
                                                                                                                                                                 .
I$: 800-1984
the weight of steel used when applied in appropriate cases. The end con-
nections of members of the frame shall have sufficient rigidity to hold the
original angles between such members and the members they connect
virtually unchanged.   Unless otherwrse specified, the ‘design shall be based
on theoretical methods of elastic analysis and the calculated stresses shall
conform to the relevant provisions of this standard. Alternatively, it shall
                                                                                        SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                        LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
be based on the principles of plastic design as given in Section 9 of the code.
   3.4.7 Exfierimentally Based Design - Where structure is of non-conven-
tional or complex nature, the design may be based on full scale or model
tests subject to the following conditions:
       a>A full scale test of prototype   structure may be done. The prototype
            shall, be accurately measured before testing to determine the
            dimensional tolerance in all relevant parts of the structure; the
            tolerances then specified on ,the drawing shall be such that all
            successive structures shall be in practical conformity with the
            prototype. Where the design is based on failure loads, a load
            factor of not less than 2.0 on the loads or load combinations given
            in 3.4.2 shall be used. Loading devices shall be previously cali-
            brated and care shall be exercised to ensure that no artificial
            restraintsiare   applied to the prototype by the loading systems.
            The distribution and duration of forces applied in the test shall
            be,representative of those to which the structure is deemed to be
            subjected.
       b)   In the case where design is based on the testing of a small scale
            model structure, the model shall be constructed with due regard
            for the principles of dimensional similarity. The thrusts, moments
            and deformations under working loads shall be determined by
            physical measurements made when the loadings are applied to
            simulate the conditions      assumed in the design of the actual
            structure.
3.5   Geometrical ,Prop&ties
    3.5.1 General - The geometrical .properties of the gross and the effec-
tive cross sections of a member or part thereof shall be calculated on the
following basis:
       a) The properties of the gross cross section shall be calculated .from
          the specified size of the member or part thereof.
       b) The properties of the effective cross section shall be calculated by
          deducting from the-area of the gross cross section the following:
           i) T,he sectional area in excess of effective plate width, as given
              in 3.5.2, and
          ii) The sectional areas of all holes in the section, ,exce@’ fhtit ,$qc ,!,
              parts in compression ( see 3.6 ).
                                          26
                 ..,...
                      ..I,..    -       .“~__   _.“.l-,_     _._-
                                                                                            -“---,~-..l                   .--   ._._   -.                              .                     ,..
                                                                                                                    IS:808-1984
  3.5.2     Plate Thickness
       3.5.2.1 If the projection of a plate or flange beyond its connection
to a web, or other line of support or the like, exceeds the relevant values
given in (a), (b) and (c) below, the area of the excess flange shall be
                                                                                                                                            SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                                            LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
neglected     when calculating   the effective geometrical properties of the
section.
                                                                                     256 ?
      a) Flanges and plates in compression                                           -     subject                  to a maximum
         with unstiffened edges                                                      AlfT-                                  of 16~4
      b) Flanges and plates in compression                                           20 ~~ to the innermost                     face of
         with stiffened edges                                                                  the stiffening
      C)    Flanges            and     plates in tension                               201,
           NOTE 1 - Stiffened flanges shall include flanges composed                                                   of channels                         or
      I-sections or of plates with continuously stiffened edges.
          NOTE 2 - ‘II/denotes the thickness of the flange of a section or of a plate in
      compression, or the aggregate thickness of plates, if connected together in accor-
      dance with the provisions of Section 8, as appropriate.
              NOTE 3 -              The width ofthe outstand of members referred above shall be taken
          as follows:
                               ?W                                                   Width of Outstand
      Plates                                                             Distance from the free edge to the first
                                                                          row of rivets or welds
          Angle, channels, Z-sections                        and         Nominal width
            stems of tee sections
          Flange of beam and tee sections                                   Half the nominal width
      3.5.2.2 Where a plate is connected to other parts of a built up member
along lines generally parallel to the longitudinal   axis-of the member, the
width between any two adjacent    lines of connections    or supports shall not
exceed the following:
                                                                                           1440 '11
      a) For plates                  in uniform               compression    z                                   subject to a maxi-
                                                                                           JfY                     mum of 901,
             However,               where the width exceeds                      -                        _-
                 560 71
                                     subject               to a maximum       of 357,for                       welded plates which
                -77
                                      are not stressed relieved,                      or
                 80011
                                      subject              to a maximum       of 507,‘for                      other plates,
                q?’
             the excess width shall be assumed to be located centrally and its
             sectional area shall be neglected when calculating   the effective
             geometrical  properties of the section.
                                                                    27
fS:800-1984
     b) For plates in uniform tension - lOOl1. However where the width
        exceeds 60 T1, the excess width shall be assumed to be located
        centrally and its sectional area shall be neglected when calculat-
        ing the geometrical properties of the section.
                 In this rule,~shall be taken to be the thickness of the plate,
                                                                                   SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                   LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
           irrespective of whether the plate is a flange or a web of the
           member.
      3.5.2.3 The provisions contained in 3.5.2.1 and 3.5.2.2 shall not be
applicable to box girders ( where width/depth is greater than 0.2 ) . In
such cases strength is not usually governed by lateral buckling. However,
in such cases check should be exercised for local buckling and yield stress
of material.
      3.5.2.4 For only the diaphragm of the box girder, all the provisions
pertaining to size, thickness, spacing etc. as given in 3.5.2.1 and 3.5.2.2
for plate girders shall be applicable.
3.6 Holes
   3.6.1 Diameter - In calculating the area to be deducted for rivets, bolts
or pins, the diameter of the hole shall be taken.
      3.6.1.1 In making deduction for rivets less than or equal to 25 mm
in diameter, the diameter of the hole shall be assumed to be 1.5 mm in
excess of the nominal diameter of the rivet unless specified otherwise. If
the diameter. of the rivet is greater than 25 mm, the diameter of the hole
shall be assumed to be 2:O mm in excess of the nominal diameter of the
rivet unless specified otherwise.
      3.6.1.2 In making deduction for bolts, the diameter of the hole shall
be assumed to be 1.5 mm in excess of the nominal diameter of the bolt,
unless otherwise specified.
     3.6.1.3 For counter sunk rivets or bolts the appropriate addition shall
be made to the diameter of the hole.
   3.6.2   Deduction for Holes
      3.6.2.1 Except as required in 3.6.2.2 the areas to be deducted shall
be the sum of the sectional area of the maximum number of holes in any
cross section at right angles to the direction of stress in the member for:
       a) all axially loaded tension members,
       b) plate girders    with d/t ratio    exceeding   the limits specified in
          6.7.3.1:
                                        28
                                                                           IStsoo-1984
      where
            t = thickness of web, and
            d = depth of the girder to be taken as the clear distance
                between flange angles or where there are no flange angles
                the clear distance between flanges ignoring fillets.
                                                                                             SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                             LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
     3.6.2.2 Where bolt or rivet holes are staggered, the area to be
deducted shall be the sum of the sectional areas of all holes in a chain of                                    ,
lines extending     progressively    across the member,          less -$   for each line
extending between holes at other than right angles to the direction of
stress, where, s, g and t are respectively the staggered pitch, gauge, and
thickness associated with the line under consideration [ see Fig. 3.1 (a) 1.
The chain of lines shall be chosen to produce the maximum such deduo
tion. For non-planer sections, such as angles with holes in both legs, the
gauge, g, shall be the distance along the centre of the thickness of the
section between hole centres [ SCGFig. 3.1 (b) 1.
              DIRECTION OF FORCE
                       (al Plates                            (b ) Angles
   DEDUCTION = ( Sum of sectional areas of holes B, C and D )
                FIG. 3.1    STAGGEREDPITCH, s, AND           GAUGE,g
       NOTE - In a built-up member where the        chains of holes considered in individ-
  ual parts do not correspond with the critical      chain of holes for the members as a
  whole, the value of any rivets or bolts joining   the parts between such chains of holes
  shall be taken into account in determining the     strength of the member.
                                           29
                                                                                                                                                                              .
IS:809=1984
3.7 Maximum            Slenderness Ratio
       3.7.1 The maximum slenderness ratio h                      of a beam, strut or ten-
sion member given in Table 3.1 shall not be exceeded. In this ( i ’ is we
effective length of the member ( see 5.2 ) and ‘ r ’ is appropriate radius
of gyration based on the effective section as defined in 3.5.1.
                                                                                              SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                              LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                    TABLE   3.1   MAXIMUM       SLENDERNESS        RATIOS
                                  MEMBER                                MAXIMUX SL~DEB-;
&.                                                                        NESS RATIO A
 (1)                                 (2)                                         (3)
  i)    A member carrying compressive      loads resulting from dead            180
          loads and imposed loads
 ii)    A tension member in which a reversal of direct stress due               180
          to loads other than wind or seismic forces occurs
iii)    A member subjected to compression forces resulting from                 250
          wind/earthquake     forces provided the deformation   of
          such member does not adversely affect the stress in any
          part ofthe structure
iv)     Compression   flange of a beam                                          300.
 v)     A member normally acting as a tie in a roof truss or a                  350
          bracing system but subject to possible reverse of stress
          resulting from the action of wind or earthquake forces
vi)     Tension members ( other than pretensioned     members )                 400
3.8 Corrosin Protection -                Minimum      Thickness of Metal
   3.8.1 General - Except where the provisions of subsequent clauses in
this section require thicker elements of members, the minimum thickness
of metal for any structural element shall be,, as specified under 3.8.2 to 3.8.4.
   3.8.2 Steelwork Dire&Q Exbosed to Weather - Where the steel is directly~
exposed to weather and is fully accessible for cleaning and repainting, the
thickness shall be not less than 6 mm and where the steel is directly exposed
to weather and is not accessible for cleaning and repainting, the thickness
shall be not less than 8 mm. These provisions do not apply to the webs of
Indian Standard rolled steel joists and channels or to packings.
       3.8.3   Steelwork not Directly Exposed to Weather
     3.8.3.1 The thickness of steel in main members                    not directly exposed
to weather shall be not less than 6 mm.
     3.8.3.2 The thickness of steel in secondary                  members      not directly
exposed to weather shall be not less than 4-5 mm.
                                               30
                                                                                                                                                            .
                                                                  lS:tMlO-1984
   3.8.4 Rolled Steel Beams ‘and Channels - The controlling thickness as
specified ‘under 3.8.2   and 3.9.3 for rolled beams and channels shall
be taken as the mean thickness of flange, regardless of the web thickness.
   3.8.5 The requirements of thicknesses specified under 3.8.2 to 3.8.4 do
not apply to special light structural work or to sealed box section or to
                                                                                   SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                   LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
steel work in which special provision against corrosion, such as use of
special paints has been made or to steelwork exposed to highly corrosive
industrial fumes or vapour or saline atmosphere.       In such cases the
minimum thickness of structural and secondary members shall be mutually
settled between the customer and the designer.
3.9 Increase of Stresses
   3.9.1 General - Except as specified in 3.9.2 to 3.9.4, all- parts of the
structure shall be so proportioned that the working stresses shall not exceed
the specified values.
  3.9.2    Increase in PermaZble   Stresses in Members Proportioned   for Occasional
Loadings
     3.9.2.1 Wind or earthquake loads
     4                                         When the effect of wind or
           Structural steel and steel castings -
           earthquake load is taken into account, the .permissible stresses
           specified may be exceeded by 334 percent.
      b)   Rivets, bolts and tension rods - When the effect of the wind or
           earthquake load is taken into account, the permissible stresses
           specified may be exceeded by 25 percent.
      3.9.2,2   Erection loads
      a) Secondary c$ec&without   wind or earthquake loaa!s- For constructions
         where secondary effects are considered without wind or earthquake
         loads, the permissible stresses on the member or its connections
         as specified may be exceeded by 25 percent.
      b) Secondary e$ccts combined with wind or earthquake loads - When
         secondary     effects are considered      together   with wind or
         earthquake,loads, the increase in the permissible stresses shall be as
         specified in 3.9.2.1.
      3.9.2.3 In no case shall a member or its connections have less
carrying capacity than that needed if the wind or earthquake loads or
secondary effects due to erection loads are neglected.
   3.9.3 Increase in Permissible Stresses for Design of Gantry Girders and Their
Supporting Structures - While considering the simultaneous effects of vertical
and horizontal surge loads of cranes for the combination given in 3.4.2.3
and 3.4.2.4 the permissible stresses may be increased by 10 percent.
                                          31
 lstmo-1984
     3.3.4 Where the wind load is themain load acting on the structure, no
increase in the permissible stresses is ‘allowed.
 3.10 Fluctuation     of Stresses
    3.10.1 Members subjected to fluctuations of stresses are liable to suffer
 from fatigue failure caused by loads much lower than those which would
                                                                                  SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                  LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
 be necessary to cause failure under a single application.         The fatigue
 cracks are caused primarily due to stress concentrations introduced by
 constructional details. Discontinuities such as bolt or rivet holes, welds and
 other local or general changes in geometrical form cause such stress con-
 centrations from which fatigue cracks may be initiated, and these cracks
 may subsequently propagate through the connected or fabricated members.
        All details shall, therefore, be designed to avoid, as far as possible,
 stress concentrations likely to result in excessive reduction of the fatigue
 strength of members or connections. Care shall be taken to avoid sudden
 changes of shape of a member or part of a member, especially in regions
 of tensile stress or local secondary bending.
        Except where specificaily stated to the contrary, the permissible
 fatigue stresses for any particular detail are the same for all steels.
    3.10.2 When subjected to fluctuations of stresses the permissible stresses
 shall be the basic stress stipulated in IS : 1024-1979 for differentfmrll/fmsr
 and for different number of stress cycles and classes of constructional
 details.
       The following provisions shall also be considered while determining
 the permissible stress in members subjected to fluctuations of stress:
       4    While computing the value off ml=/f msx the effect of wind or
            earthquake temperature and secondary stresses shall be ignored
       b)   For plain steel in the as-rolled condition with no gas cut edges
            the constructional detail shall be considered as Class A of IS :
             1024-1979.
       4    For members of steel with yield stress 280 MPa and over, and
            fabricated or connected with bolts or rivets the construction
             details shall be considered as Class C of IS : 1024-1979.
            For members        of steels with yield stress below 280 MPa,
            fabricated or connected with bolts or rivets the construction
             details shall be considered’as Class D of IS : 1024-1979.
            The value off max shall not exceed the permissible tensile or com-
             pressive fatigue stress as determined from IS : 1024-1979. Where
             co-existent bending and shear stresses are present, f mpxshall
             be taken as the principal stress at the point under considera-
             tion.
                                        32
3.11 Resistance    to Horizontal   Foaces
   3.11,1 In designing the steel framework of building, l.&visions shall be
made by adequate moment connections or by a system of bracing to
effectively transmit to the foundations all the horizontal forces, making
due allowance ‘for the stiffening effect of the walls and floors, where appli-
cable.
                                                                                 SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                 LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
   3.11.2 When the walls, or walls and floors and/or roof are capable of
effectively transmitting all of the horizontal forces directly to the founda-
tions, the structural framework may be designed without considering the
effect of wind.
   3.11.3 Wind, and earthquake forces are, reversible and therefore calls
for rigidity in both longitudinal and transverse directions. To provide for
torsional effects of wind and earthquake forces bracings in plan should be
provided and integrally connected with the longitudinal and transverse
bracings to impart adequate torsional resistance to the structure.
       3.11.3.1 In shed type buildings, adequate provisions shall be made
by wind bracings to transfer the wind or earthquake loads from trbeir
 points of action to the appropriate supporting members.     Where the Gon-
nections to the interior columns are so designed that the wind or earth-
quake loads are not transferred to the interior columns, the extlerior
columns shall be designed to resist the total wind or earthquake loads.
Where the connections to the interior columns are so designed that the
wind or earthquake effects are traniferred to the interior columns also, both
exterior and interior columns shall be designed on the assumption that the
wind or earthquake load is divided among them in proportion to their
relative stiffnesses. Columns also should be tested for proper anchorage to
the trusses and other members to withstand the uplifting effect caused by
 excessive wind or earthquake pressure from below the roof.
       3.11.3.2 Earthquake forces are proportional to the mass of   structural
component and the imposed load. Therefore earthquake forces         should be
applied at the centre of gravity of all such components of loads    and their
transfer to the foundation should be ensured ( see IS : 1893-1975   ).
      3.11.3.3 In buildings where high-speed travelling cranes are support-
ed by the structure or where a building or structure is otherwise subj,ected
to vibration or sway, triangulated bracing or especially rigid portal
systems shall be provided to reduce the vibration or sway to a suitable
minimum.
   3.11.4 Foundations- The foundations of a building or other structure
shall be so designed as to ensure such rigidity and strength as have been
allowed for in the design of the superstructure, including resistance to all
forces.
                                     “33
_ls:800-1984
   3.11.5 Overhang of Walls - Where a wall is placed eccentrically upon
the flange of a supporting steel beam, the beam and its connections shall be
designed for torsion, unless the beam is encased in solid concrete and
reinforced in combination with an adjoining solid floor slab in such a way
as to prevent the beam deforming torsionally.
                                                                                            SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                            LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
3.12 Stability
   3.12.1 The stability of the structure as a whole or of any part of it shall
be investigated, and weight or anchorage shall be provided so that the
least restoring moment and anchorage, shall be not less than the sum of
 12 times the maximum overturning moment due to dead load and 1.4
times the maximum overturning moment due to imposed loads and wind
or earthquake loads.
      3.12.1.1 In cases where dead load provides the restoring moment,
only O-9 times the dead load shall be considered. Restoring moment due
to imposed loads shall be ignored.
      3.12.1.2 To ensure stability at all times, account shall be taken of
probable variations in dead load during construction, rapair or other tem-
porary measures. The effect on the load from the deflected or deformed
shape of the structure or of individual elements of the lateral load resisting
systems, may be considered as required.
        NOTEI -In      complying with the requirements      of 3.12.1, it is necessary to
   ascertain that the resulting pressures and shear forces to be communicated     by the
   foundations to the supporting soil would not cause failure.
        NOTE 2 - All individual members of the structure which have been designed
   for their dead and imposed loads, wind or earthquake loads to the permissible stresses
    stipulated in this code shall be deemed to be adequately covered for this margin
   of stability.
3.13 Limihg        Deflection
   3.13.1 Limiting    Vertical Deflection
      3.13.1.1 The deflection of a member shall be calculated without con-
sidering the impact factor or dynamic effect of the loads causing defiec-
tion.
       3.13.1.2 The deflection of member shall not be such as to impair
the strength or efficiency of the structure and lead to damage to finishings.
Generally, the maximum deflection should not exceed l/325 of the span,
but this limit may be exceeded in cases where greater deflection would not
impair the strength or efficiency of the structure or lead to damage to
finishings.
                                            34
      3.13X4 In t&e case of crane runway girder the maximum- vertical
deflection under dead and imposed loads shall not exceed the following
values:
                                                                  L
      4                                                             500
                                                                             SUPPLIED BY BOOK SUPPLY BUREAU
                                                                             LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                                                                        L
      W    Where electric overhead travellingcranes operate,
                                                                     750
           upto5Ot
                                                                     L
           Where electricoverhead _travellingcranes operate,       -
      =I                                                           loo0
           over 5ot
                                                                    L
      4    Other moving loads such as charging cars, etc
                                                                    600
      where,
          L=spanofcranerunwaygirder.
   3.13.2 GmitingHi      De&c&m
      3.13.2.1 At the caps of cohmms in single storey buildings, the ho+
zontal deflectiondue to lateral forces should not ordinarily exceed l/325
of the actual length ‘P of the column. This limit &y be exceeded in cases
where greater deflection would not impair the strength and effitiency of
the structureor lead to damage to iinishing.
      3.13.2.2 The horizontal deflection at column cap. level of columns
supportingcrane runway girdersin the building shall not exceed limits as
may be speci6ed by the purchaser.
3.14 Expansion     Joints
   3.14.1 In view of the large number of factors involved in deciding the
location, spacing and nature of expansion joints, provisionsof expansion
joints should be left to the discretionof the designer.
   3.14.2 Structures in which marked changes in plan dimensions take
place abruptly shall be provided wi_thexpansionjoints at the sectionwhere
such changes occur. Expansionjoints shall be so provided that the neces-
sary movement occurs with a minimum resistanceat the joint. The struc-
ture adjaent to the .joint should preferably be supportedon separate
columns but not necessarilyon separatefoundation.
   3.14.3 The details as to the length of a structurewhere expansionjoints
have to be provided may be determined after taking into conrideration
various factors such as temperature, exposure to weather and structural
design, etc. For the purposeof g:,leral guidance the. following pnxisions
have been recommended:
      4 If one set of column longitudinal bracing is provided at the
          centre of the building pr building section, the length of the
          building section may be restricted to 180 metres in case of
         covered buildings and 120 metres in case of open gantries
          ( w Fig. 3.2 ).
IS:888-1984
      b> if  one set of column bngitudinal bracing are provided near
         cenfre of the building/section, the maximum centre line distance
         between the two sets of bracing may be restricted to 48 metres for
         covered buildings ( and 30 metres for open gantries ) and the
         maximum distance between centre of the bracing to the nearest
                                                                              SUPPLIED BY BOOK SUPPLY BUREAU
                                                                              LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
         expansion joint/end of ‘building or section may be restricted to
         90 metres ( 60 metres in case of open gantries ). The maximum
         length ofthe building section thus may be restricted to 228 metres
         for covered buildings [ and 150 ‘metres for open gantries ( xee
         Fig. 3.3)].
      C>The    maximum width of the covered building section should
         preferably be rest&ted     to 150 metres beyond which suitable
         provisions for the expansion joints may be made.
        FIO. 3.2   MAXIWM LENGTH OF BUILDINGws%              ONE SET
                        OF COLUMNBRACING
                                        EXPANSION   JOINi-
              FIG. 3.3 MAXIMUMLENGTH OF BUILDINQS~SECTION
                      WITHTwo SETSOF COLUMNBRACINCN
                                                                        lS:&lo-1984
         SECTION             4       DESIGN OF TENSION         MEMBERS
4.1 Axial Stress
   4.1.1 The permissible stress in axial tension, oat, in MPa               on the net
                                                                                           SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                           LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
effective area of the sections shall not exceed:
     where,
              f y = minimum yield stress of steel, in MPa
4.2 Design Details
  4.2.1 .Net Effective Areasfor         Angles and Tees in Tension
      4.2.1.1  In the case of single angle connected             through one leg the
net effective sectional area shall be taken as:
                                             Al + A&
     where
              AI =    effective cross-sectional area of the connected leg,
              Aa =    the gross cross-sectional area of the unconnected leg, and
                      3A1
               k = 32, + A;
      Where lug angles are used, the effective sectional             area of the whole
of the angle member shall be considered.
     4.2.1.2 In the case of a pair of angles back-to-hack ( or a single tee )
connected by one leg of each angle ( or by the flange of the tee ) to the
same side of a gusset, the net effective area shall be taken as
                                         Al + Ask
     where
                     Al and A, are as defined in 4.2.1.1,        and
                                    ,5A,
                     k           .
                         =       5A1 + As
     The’anglesshall be connected together along their length in accord-
ante with the requirements under 8.10.3.3.
       4.2.1.3 For double angles          or tees placed back-to-back and connect-
ed to each side of a gusset or to          each side of part of a rolled sections the
areas to be taken in computing            the mean tensile stress shall be the effective
area provided the members are              connected together along their length as
specified in 8.10.3.3
                                              37
IS:800-1984
            Where the angles are back-to-back but are not tack riveted
      4.2.1.4
or welded according to 8.10.3.3 the provisions under 4.2.1.2 and 4.2.1.3
shall not apply and each angle shah be designed as a single angle
connected through one leg only in accordancewith 4.2.1.1.
      4.2.1.5 When two tees are placed back-to-back but are not tack
riveted or welded as per 8.1033 the provisions under 4.2.1.3 shah not
apply and each tee shall be designed as a singIetee connected to one side
                                                                                      SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                      LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
of a gussetonly in accordance with 4.2.1.2.
        NOTE - The area of the leg of an angle shall he taken as the product of the
   thickness +nd the length from the outer corner minus half the thickness. and the area
   of the leg of a tee as the product of the thickness and the depth minus the thickness
   of the table.
      SECTION        5   DESIGN OF COMPRESSION                   MEMBERS
5.1 Axial Stresses in Uncased Struts
  5.1.1 The direct stress in compression on the gross sectionalarea of
axially loaded compressionmembers shall not exceed 0.6~r nor the per-
missiblestressu,, calculated using the following formula:
      where
              CM = permissiblestressin axial compression,in MPa;
                                                             .
              fP= yield stressof steel, in M.Pa;
                                                                    &E
              foe=    ehtic   critical stress in compression,= F
               E = modulus of elasticity of steek 2 x 106 MPa;
      A ( = l/r) = slendernessratio of the member, ratio of the eiGc&re
                   length.to appropriate radius of gyration; and
                n-a&factor      assumed as 1.4.
     Values of tr.,, for some of the Jr&an Standard structuralsteelsare
given in Table 5.1 for convenience.
5.2 EffoctiveLength        ofCompredonMember8
  5.2.1 Gencrd- The slendernessratio of a strut shah be calculated as
the.ratio of the effective length, 1, $o the appropriateradius of gyratioq r.
The effectivelength, 1 shall be derived Corn the actual length, L. The
actualstrut length shah be taken as the length from the centrMo-centre of
                                          38
                                                                                                                                                                       .
                                                                                                                                       SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                                       LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                   TABLE      5.1    PERMISSIBLE  STRESS uac ( MPa N AXIAL COMPRESSION
                                       FOR STEELS WITH VARIOUS YIELD STRESS
                                                         ( czuusc 5.1.1   )
          220     230   243         250   260   280    300    320    340      360    380    400     420     450    480    510    540
     10    132    138   144         150   156   168    180    192    204      215    227    239     251     269    287    305    323
           131    137   142         148   154   166    177    189    201      212    224    235     246     263    280    297    314
    zi     128    134   140         145   151   162    172    183    194      204    215    225     236     251    266    280    295
           124    129                     145   154    164    174    183      192    201                    231    243    255    267
    sx     118    123   u”;         n;    136   145    153    161     168     176    183    %       :A;                          233
                  115   118         122   126   133    139    146    152      158     163   168      173    f;;    Z;     225
                                                                                                                          193
    %      102    106   1;;         ;A$   ;g    120    125    130    135      139     142   147      150    155    160    164    :z
            93                                  107    111    115    118      121    124    127     129     133    136    139    141
    2       8.5    :;      88        90    92           98     101    103      105    108   109      111    114    116    118    119
            76                                   ii:    86                      92                    96                         101
g   :t             78
                   69      71
                           79        %     !Z    74     76     tt               LO    iif    ii;      83     ii     85
                                                                                                                    gg    lizi
    120     :i                                                 67               70    71_    71       72     73     iz     74    ;;
    130     55                                                                                                                   65
    140     49                                                 z:                     2      ti:
                                                                                             49
                                                                                                     fZ
                                                                                                     49
                                                                                                             ::     56     it    57
    150                                                        47                     48                                         50
    160     2                                                                         43             43      ii     49     50
                                                                                                                           44    44
    170                                                        ifi                           ;i
    180                                                        34                            35      3359    iii    35
                                                                                                                    iii   iz      ;z
    190
                                                               zti                           2381    ;i      :i      32    ;:    :z
    fZ
    220                                                 23
                                                               26              26
                                                                               24
                                                                                      26
                                                                                      24     ;:
                                                                                                     26
                                                                                                     24
                                                                                                             26     ::     26    26
    230
    240
                                                 ;:     22     2
                                                               20
                                                                               22
                                                                               20
                                                                                      22
                                                                                      20
                                                                                             22
                                                                                             20      if
                                                                                                             24
                                                                                                             2’:
                                                                                                                    ii
                                                                                                                    20
                                                                                                                           fi
                                                                                                                           20
                                                                                                                                 ;:
                                                                                                                                 20
    250                                          2o
                                                 18     :80    18              19     19     19      19      19     19     19    19
  .       _       ._. .   -. . -.. .   _.    --     .--   ---
lS:tUlO       -1984
inter-sections with supporting members, or the cantilevered     length in the
case of free-standing struts.
   5.2.2 E_$ective Length - Where accurate frame analysis is not done, the
effective length of a compression member in a given plane may be deter-
mined by the procedure given in Appendix C. However, in most cases the
effective length in the given plane assessed on the basis of Table 5.2,
                                                                                 SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                 LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
would be adequate.       Effective length as given in Table 5.2 may also be
adopted where columns directly form part of framed structures.
    5.2.3 Eccentric Beam Connections - In cases where the beam connections
are eccentric with respect to the axes of the columns, the same conditions
of restraint shall be deemed to apply, provided the connections are carried
across the flange or web of the columns as the case may be, and the web
of the beam lies within, or .in direct contact with the column section.
Where practical difficulties prevent this, the effective length shall be
estimated to accord with the case appropriate to no restraint in that
direction.
   5.2.4 Members of Trusses - In the case of bolted, riveted or welded
trusses and braced frames, the effective length ‘ 1’ of the compression mem-
bers shall be taken as between 0.7 and 1.0 times the distance between
centres of inter-sections, depending on the degree ,of end restraint provid-
ed. In the case of members of trusses buckling in the plane perpendicu-
lar to the plane of the truss the effective length shall be taken as 1.0 times
the distance between points of restraints. The design of disc_ontinuous angle
struts shall be as specified in 5.5.
   5.2.5 Stepped Columns - A method of determining the effective length of
stepped columns is given in Appendix D.
5.3 Des@       Details
    5.3.1 Thickness of Elements - The thickness of an outstanding leg of any
member in compression shall be in accordance with 3.5.2.1 and 3.5.2.2.
    5.3.2 @fictive Sectional Area - Except as modified under 3.5.2 the gross
sectional area shall be taken for all compression members connected by
welds and turned and fitted bolts and’pins except that holes, which are not
fitted with rivets, weld or tight-fitting bolts and pins, shall be deducted.
  5.3.3   ficentricity for Stanchion and Solid Columns
       5.3.3.1 For the purpose of determining the stress in a stanchion or
column section, the beam reactions or similar loads shall be assumed to be
applied 100 mm from the face of the section or at the centre of bearing
whichever dimension gives the greater eccentricity, and with the exemption
of the following two cases:
      a) In the case of cap connections, the load shall be assumed to be
         applied at the face of the column shaft or stanchion section; or
         edge of packing if used, towards the span of the beam; and
                                        40
                                                              18 I   888                -   1984
         TABLE 5.2         EFFECTIVE LENGTH OF COMPRESSION   MEMBERS
                               OF CONSTANT DIMENSIONS
                                      ( Clause 5.2.2 )
     DEGREEOFEND  RESTRAINT OB               RECOMMENDED      SYMBOL
                                               VALUE OF
                                                                                                   SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                   LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
        COMPRESSION Mmrnmt
                                              EFFECTIVE
                                                LENGTH
                     (1)                        (2)              (3)
a)    Effectively   held in position and        0’65 L
      restrained    against rotation   at
      both ends
b)    Effectively  held in position at          0.80   L
                                                                \,
      both ends and restrained against
      rotation at one. end
c)    Effectively
      both ends, but
                    held
      against rotation
                            in position at
                            not restrained
                                              41
                                                l-00   L
                                                                1      /’
                                                                            I
                                                                                I
                                                                       ( Canfinued)
                                                                                    I
                                                                                    ;
1.
L.                                        _    .,    _.                  ._~..
      fS:888- 1984
               TABLE    5.2    EFFECTIVE  LENGTH OF COMPRESSION                  MEMBBBS
                                OF CONSTANT   DIMENSIONS - Cod
          DEGREE oY END RESTRAINT OP                  RECOMMENDED                5YhtBOL
             COMPREBSION MEYBEB                         VALWOB
                                                        EEXXCTIVE
                                                         LENGTH
                                                                                           SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                           LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                         (1)                                   (2)
     d)    Effectively  held in position      and           1’20     L
           restrained against rotation at     one
           end, and at the other end          res-
           trained against rotation but       not
           held in position
     e)    Effectively held in position and                1’50      L
           restrained against    rotation   at
           one end, and at the other end
           partially    restrained     against
           rotation but not held in position
     f)   Effectively  held in position at                2’00     L
          one end but not restrained
          against rotation, and at the other
          end restrained against rotation
          but not held in position
                                                          42
                                                                        tS : 804 - 1984
        TABLE    5.2      EFFECTIVE  LENGTH OF C&IMPRESSION           MEMBEBS
                            OF CONSTANT   DIMENSIONS - Contd
     DE~UEE OCR  END RESTEAINT OB           RE~OMXENDED                     SYMBOL
        C~IUTSSSION   MEIXBEX                VALUE OF
                                             EFFECTIVE
                                              LENGTH
                                                                                           SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                           LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                    (1)
g)    Effectively held in position and
      rdstrained against rotation at
      one end but not held in position
      n0r restrained against rotation
      at the other end
         NOTE 1 -      L is the unsupported length of compression member.
         NOTE 2 -For       battened struts the effective length shall be increascd.by 10
     percent.
        b) In the case of a roof truss bearing on a cap, no eccentricity need
           be taken for simple bearings without connections capable of
           developing an appreciable moment.
     5.3.3.2 In continuous columns, the bending moments due to
eccentricities of loading on the columns at any floor may be taken as:
        a) ineffective at the floor levels above and below that floor; and
        b) divided equally between the column’s lengths above and below
           that floor level, provided that the moment of inertia of either
           column section, divided by its effective length does not exceed
           l-5 times the corresponding value of the other column. In case
           where this ratio is exceeded, the bending moment shall be divided
           in proportion to the moments of inertia of the column sections
           divided by their respective effective lengths.
     53.4 S#ices
      5.3.4.1 Where the ends of compression members are faced for
bearing over the whole area, they shall be spliced to hold the connected
members accurately in position, and to resist any tension when bending is
present.
     The ends of compression members faced for bearing shall invariably
be machined to ensure perfect contact of surfaces in bearing.
 IS t 800 - 1984
       5.3.4.2 Where such members are not faced for complete bearing the
splices shall be designed to transmit all the forces to which they are
subjected.
       5.3.4.3 Wherever possible, splices shall be proportioned         and
arranged so that the centroidal axis of the splice coincides as nearly as
possible with the centroidal axes of the members jointed in order to avoid
                                                                                  SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                  LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
eccentricity; but where eccentricity is present in the joint, the resulting
stress shall be provided for.
5.4 Column     Bases
   5.4.1 Gusseted Bases-For   stanchion with gusseted bases, the gusset plates,
angle cleats, stiffeners, fastenings, etc, in combination with the bearing
area of the shaft shall be sufficient to take the loads, bending moments
and reactions to the base plate without exceeding specified stresses. All the
bearing surfaces shall be machined t) ensure perfect contact.
       5.4.1.1 Where the ends of the column shaft and the gusset plates
are not faced for complete bearing, the fastenings connecting them to the
base plate shall be sufficient to transmit all the forces to which the base is
subjected..
   5.4.2 Column and Base Plate Connections - Where the end of the column
is connected directly to the base plate by means of full penetration butt
welds the connection shall be deemed to transmit to the base all the forces
and moments to which the column is subjected.
    5.4.3 Slab Bases - Columns with slab bases need not be provided with
gussets, but fastenings shall be provided sufficient to retain the parts
securely in plate and to resist all moments and forces, other than direct
compression, including those arising during transit, unloading and erection.
When the slab alone distributes the load uniformly, the minimum
thickness of a rectangular slab shall be given by the following formula:
                       t=d_$(aa-$)
   where
             t = the slab thickness, in mm;
             w = the pressure or loading on the underside of the base,
                  in MPa;
             a = the greater projection of the plate beyond column, in
                  mm;
                                      44
                                                                   IS : 800 - Aad4
             b = the lesser projection       of the plate beyond     the coiumn,
                 in mm; and
           bba = the permissible bending stress in slab bases ( for a11steels,
                  shall be assumed as 185 MPa ).
                                                                                     SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                     LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
     5.4.3.1 When the slab does not distribute the loading uniformly or
where the slab is not rectangular, special calculations shall be made to
show that the stresses are within the specified limits.
      5.4.3.2 For solid round steel columns, in cases where the loading on
the cap or under the base is uniformly distributed over the whole area
including the column shaft, the minimum thickness of the square cap or
base shall be:
                                     90 w            B
                     t=10          ____           ~
                                    16 abs    ’   B-do
   where
              t   the thickness of the plate, in mm;
            W 1   the total axial load, in kN;
             B = the length of the side of cap or base, in mm;
           gbs =  the permissible bending stress in slab bases ( for all steels,
                   shall be assumed as 185 MPa ); and
            d,, = the  diameter of the reduced end, if any, of the column,
                  in mm.
       5.4.3.3 When the load on the cap or under the base is not uniformly
distributed or where end of the column shaft is not machined with the cap
or base, or where the cap or base is not square in plan, calculations shall
be made based on the allowable stress of 185 MPa.
      5.4.3.4 The cap or base plateshall not be less than l-5( do + 75 ) mm
in length or diameter.
       5.4.3.5 The area of the shoulder ( the annular bearing area ) shall
be sufficient to limit the stress in bearing, for the whole of the load com-
municated to the slab, to the maximum values given in 6.3, and resistance
to any bending communicated to the shaft by the slab shall be taken as
assisted by bearing pressures developed against the reduced end of the
shaft in conjunction with the shoulder.
      5.4.3.6 Bases for bearing upon concrete or masonry need not be
machined on the underside provided the reduced end of the shaft termi-
nates short of the surface of the slab, and in all cases the area of the
reduced end shall be neglected in calculating the bearing pressure from the
base.
                                      45
-.
            5.4.3.7 In cases where the cap or base is fillet welded direct to the
     end of the column without boring and shouldering, the contact surfaces
     shall be machined to give a perfect bearing and the welding shall be
     sufficient to transmit the forces as required in 5.43 and its sub-clauses for
     fastening to slab bases. Where full strength T-butt welds are provided no
                                                                                        SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                        LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
     machining of contact surfaces shall be required.
        5.4.4 Base Plates and Bearing Plates - The base plates and grillages of
     stanchions and the bearing and spreaders of beams and girders shall be
     of adequate strength, stiffness and area, to spread the load upon the eon-
     Crete, masonry, other foundation, or other supports without exceeding the
     permissible stress on such foundation under any combination of load and
     bending moments.
     5.5 Angle Struts
       5.5.1   Single Angle Struts
          a) Single angle discontinuous struts connected by a single rivet or
             bolt may be designed for axial load only provided the compressive
             stress does not exceed 80 percent of the values given in Table 5.1
             in which the effective length c 1 ’ of the strut shall be taken as
             centre-to-centre of intersection at each end and ‘ r ’ is the mini-
             mum radius of gyration. In no case, however, shall the ratio of
             slenderness for such single angle struts exceed 180.
          b) Single angle discontinuous struts connected by a weld or by two
             or more rivets or bolts in line along the angle at each end may
             be designed for axial load only provided the compression stress
             does not exceed the values given in Table 5.1, in which the
             effective length ‘ 1’ shall be taken as 0.85 time the length of the
             strut, centre-to-centre of intersection at each end and ‘ I ’ is the
             minimum radius of gyration.
       5.5.2 Double Angle Strutr
           a) For double angle discontinuous struts, back to back connected to
              both sides of the gusset or section by not less than two bolts or
              rivets in line along the angles at each end, or by the equivalent
              in welding, the load may be regarded as applied axially. The effec-
              tive length ‘ I ’ in the plane of end gusset shall be taken as between
              0.7 and 0.85 times the distance between intersections, depending
              on the degree of the restraint provided and in the plane perpen-
              dicular to that of the end, gusset, the effective length ‘ I ’ shall be
              taken as equal to the distance between centres of intersections.
              The calculated average compressive stress shall not exceed the
              values obtained from,Table 5.1 for the ratio of slenderness based
              on the appropriate radius of gyration.       The angles shall be con-
              nected tegether in their lengths so as to satisfy the requirements
              of 5.9 and 8.10.3.
                                           46                 1
                                                                  IS : 800 - 1984
      b)   Double angle discontinuous ,struts back-to-back, connected to one
           side of a gusset or section by a one or more bolts or rivets in each
           angle, or by the equivalent in .welding, shall be designed as for
           single angles in accordance with 5.5.1 (a) and the angles shall be
           connected together in their length so as to satisfy the require-
                                                                                     SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                     LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
           ments of 5.9 and 8.10.3.
   5.5.3 Continuous Members - Single or double angle continuous struts, such
as those forming the flanges, chords or ties of trusses or trussed girders, or the
legs of towers shall be designed as axially loaded compression members,
and the effective length shall be taken in accordance with 5.2.4.
   5.5.4 Combined Stresses - If the struts carry, in addition to axial loads,
loads which cause transverse bending, the combined bending and axial
stresses shall be checked in accordance with 7.1.1.    For determining the
permissible axial and bending stresses, for use in applying 7.1.1, the
effective length shall be taken in accordance with 5.2 and 6.6.1, respec-
tively.
5.6 Steel Castings - The use of steel castings shall be limited to bear-
ings, junctions and other similar parts and the working stresses shall not
exceed the workings stresses given in this standard for steel of yield stress
250 MPa.
5.7 Lacing
  5.7.1    General
      5.7.1.1 Compression members’ comprising of two main components
laced and tied should where practicable, have a radius of gyration about
the axis perpendicular to the plane of lacing not less than the radius of
gyration about the axis in the plane of lacing ( see Fig. 5.1A ).
      5.7.1.2 As far as practicable the lacing system shall not be varied
throughout the length of the strut.
       5.7.1.3 Except for tie plates as specified in 5.8 double laced system
( see Fig. 5.1B ) and single laced systems on opposite sides of the main
components shall not be combined with cross members perpendicular to
the longitudinal axis of the strut unless all forces resulting from deforma-
tion of the strut members are calculated and provided for in the lacing and
its fastenings ( see Fig. 5.1C ).
      5.7.1.4 Single laced systems on opposite sides of the components
shall preferably be in the same direction so that one be the shadow of the
other, instead of being mutually opposed in direction ( see Fig. 5.1D ).
                                        47
IS: 808- 1984
  5.7.2   Design of Lacing
       5.7.2.1 The lacing of compression members shall be proportioned to
resist a total transverse shear ‘ V’ at any point in the length of the member
equal to at least 2-5 percent of the axial force in the member, which shear
shall be considered as divided equally among all transverse lacing systems
in parallel planes.
                                                                                 SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                 LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
       5.7.2.2 For members carrying calculated bending stress due to
eccentricity of loading, applied end moments and/or lateral loading, the
lacing shall be proportioned to resist the shear due to the bending in addi-
tion to that specified under 5.7.2.1.
       5.7.2.3 The slenderness ratio ‘h’ of the lacing bars for compression
members shall not exceed 145. In riveted constrpction, the effective length
of lacing bars for the determination of the permissible stress shall be take,n
as the length between the inner end rivets of thk bars for sirigle lacing,
and as O-7 of this length for double lacing $Fectively tiveted at intersec-
tion’. Ili welded construction, the effective lengths fhzill be taken as
0.7 times the distance between the inner ends of welkls connecting the
lacing bars to the member.
          xE..-3x    Y
                                           LACING ON      LACING ON
                  ry < rx                   FACE AA        FACE BB
   Fro. 5.1A     LACING DETAILS      Fro. 5.1B   DOUBLE LACING SYSTEM
                                      48
                                                                            ,
                     .
                                                                 SUPPLIED BY BOOK SUPPLY BUREAU
                                                                 LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                  ..hEi!
                    ..  .
                       .m
                .
                                             I
                               a    .            .
                  .            .    .
              .E
               ...
               /. l-2
              fiz
              1            .
                                                 .
                                                     4
                                             .
Fro> 5. IC   DOUBLE LACED AND SINQLE LACED SYSTEMS
                                                 COMBINED
                      WITHCROSSMEMBERS
                               49
                                                            ‘.
km,__..,..    .                                 .,_ -   .._...
             I8 : 888 - 1984
                                                                                                            SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                            LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                                 LACING   ON   LACING ON              LACING ON   LACING
                                                                                       ON
                                  FACE A        FACE B                 FACE A     FACE E
                                      PREFERRED                         NOT PREFERREO
                     Fro. 5.1D     SINQLE LACED SYSTEMON OPPOSITE SIDES OF
                                          MAIN COMPONENTS
               5.7.3 Width of Lacing Bars.-    In riveted construction,                       the minimum
             width of laang bars shall be as follows:
                               Nominal Rivtt Dia                       Width of Lacing Bars
                                     mm                                           mm
                                     22                                            65
                                      20                                           60
                                      18                                           55
                                      16                                           50
                5.7.4 Thickntss of Lacing Bars - The thickness of flat lacing bars shall
             be not less than one-fortieth of the length between the inner end rivets or
             welds for single lacing, and one-sixtieth of this length for double lacing
             riveted or welded at intersections.
                   5.7.4.1 Rolled sections or tubes of equivalent strength may be used
             instead of flats.
                                                                 50
                                                                                                                                                                                             .
                                                                18:800-1984
   5.7.5 Angle of Inclination - Lacing bars, whether in double or single
systems, shall be inclined at an angle not less than 40 degree nor more
than 70 degrees to the axis of the member.
       NOTE - The required section for lacing bars for compression membea or for
  tensionmembers subject to bending shall be determined by using the appropriate
                                                                                SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
  permissible stressessubject to the requirements in 5.7.5 and 5.7.4. For tension
  members under stress, only the lacing ban shall be subject to the requirements
  of 5.735.7.4 and 5.7.5.
   5.7.6 Spating
       5.7.6.1 The maximum spacing of lacing bars, whether connected by
riveting or welding, shall also be such that the minimum slenderness ratio
r\ ( I Z/r) of the components of the member between consecutive connections
is not greater than 50 or O-7 times the most unfavourable slenderness ratio
of the member as a whole, whichever is less, where ‘1 is the distance between
the centres of connection of the lattice bars to each component.
      5.7.6.2 Where lacing bars are not lapped to form the connection to
the components of the members, they shall be so connected that there
is no appreciable interruption in the triangulation of the system.
   5.7.7 Attachment to Main Members - The riveting or welding of lacing
bars to the main members shall be sufficient to transmit the load in the
bars. Where welded lacing bars overlap the main members, the amount
of lap measured along either edge of the lacing bar shall be not less than
four times the thickness of the bar or the members, whichever is less. The
welding shouid be sufficient to transmit the load in the bar and shall,
in any case, be provided along each side of the bar for the full length
of lap.
      5.7.7.1 Where lacing bars are fitted between the main members,
they shall be connected to each member by fillet welds on each side of the
b8r or by full penetration butt welds.  The lacing bars shall I)r so placed
as to be generally opposite the flange or stiffening elements of the main
member.
   5.7.8 End Tie Plates - Laced compression members shall be provided
with tie plates at the ends of lacing systems and at points where the
systems are interrupted ( see also 5.8 ).
5.8 Battening      and Tie Plates
  5.8.1 General
       5.8.1.1 Compression members composed of two main components
battened should preferably have their two main components of the same
cross section and symmetrically   disposed about their x-x axis. Where
practicable, the compression members should have a radius of gyration
                                      51
Is:mJ-1984
about the axis perpendicular to the plane of the batten not less -than the
radius of gyration about the axis in the plane of batten.
      5.8.1.2 Battened compression members not complying with the
requirements specified in thii clause or those subjected, in the plane of the
battens, to eccentricity of loading, applied moments or lateral forces ( see
Fig. 5.2 ) shall be designed according to the exact theory of elastic stability
                                                                                      SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                      LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
or empirically from the verification of tests, so that they have a load
factor of not less than l-7 in the actual structure.
                     Fro. 5.2   BATTENCOLUMN SECTION
      NOTE - If the column section ls subjected to eccentricity or other moments
  aboutl-y axis the battens and the column section should be specially designed for
  such moments.
       5.8.1.3 The battens shall be placed opposite each other at each end
of the member and points where the member is stayed in its length and
shall, as far as practicable, be spaced and proportioned uniformly through-
out. The number of battens shall be such that the member is divided
into not less than three bays within its actual length from centre to centre
of connection.
                                       52
                                                               rs:800-1984
   5.8.2 Design
      5.8.2.1 Battens - Battens shall be designed to carry the bending
moments and shears arising from transverse shear force ‘V’ of 2.5 percent
of the total axial force on the whole compression member, at any point in
                                                                                 SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                 LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
 the length of the member, divided equally between parallel planes of
battens. The main members shall also be checked for the same shear force
-and bending moments as for the battens.
      Battens shall be of plates, angles, channels, or I-sections and shall be
riveted or welded to the main components so as to resist simultaneously a
                                                       V.C
longitudinal shear VI = g       and a moment M = -
                                                       2N
      where
              V =   the transverse shear force as defined above;
              C = the distance centre-to-centre of battens, longitudinally;
              .N = the number of parallel‘pianes of battens; and
              5’ = the minimum transverse distance between the centroids
                   of the rivet group/welding.
      5.8.2.2 Tie plates - Tie plates shall be designed by the same method
as battens. In no case shall a tie plate and its fastenings be incapable of
carrying the forces for which the lacing has been designed.
       5.8.2.3 Siie - When plates are used for battens, the end battens and
those at points where the member is stayed in its length shall thave an
effective depth, longitudinally, of not less than the perpendicular distance
between the centroids of the main members, and intermediate battens
shall have an effective depth of not less than three quarters of this dis-
tance, but in no case shall the effective depth .of any batten be less than
twice the width of one member in the plane of the battens. The effective
depth of a batten shall be taken as the longitudinal distance between end
rivets or end welds.
       The thickness of batten or the tie plates shall be not less than one-
fiftieth of the distance between the innermost connecting lines of rivets or
welds.
       5.8.2.4 The requirement of size and thickness specified above does
not apply when angles, channels or I-sections are used for battens with
their legs or flanges perpendicular to the main member. However, it should
be ensured that the ends of the compression members are tied to achieve
adequate rigidity.
                                      53
IS : 800 - 1984
   5.0.3   S’acing of Battens
       5.8.3.1 In battened compression members not specifically checked for
 shear stress and bending moments as specified in 5.8.2.1, the spacing of
 battens centre-to-centre of end fastenings shall be such that the slenderness
                                                                                         SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                         LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
 ratio c A’ of the lesser main component over that distance shall be not greater
 than 50 or greater than 0.7 time the slenderness ratio of the member as
 a whole, about its X-X ( axis parallel to the battens ).
         NOTEZ- With regard to effective lesgth of the battened   coniprevion   member
    as a whole, reference may be made to Table 5.2.
       5.8.3.2 The number of battens shall be such that the member is
 divided into not less than three parts longitudinally.
    5.8.4 Attachment to Main Mmbcrs
       5.8.4.1 W&d     connections - Where tie or batten plates ovt~lap the
 main members, the amount of lap shall be not less than four times the
 thickness of the plate. The length of weld connecting each edge of the
 batten plate to the member shall, in aggregate, be not less than half the
 depth of the batten plate. At least one-third of the weld shall be placed
 at each end of this edge. The length of weld and depth of batten plate
 shall be measured along the longitudinal axis of the main member.
        In addition, the welding shall be returned along the other two edges
 of the plates transversely to the axis of the main member for a length not
 less than the minimum lap specified above.
 5.9 Compkession Members            Composed of Two Components                  Back-
 to-Back
    5.9.1 Compression members composed of two angles, channels, or tees,
 back-to-back in contact or separated by a small distance shall be connect-
 ed together by riveting, bolting or welding so that the ratio of slenderness
 of each member between the connections is not greater than 40 or greater
 than O-6 times the most unfavourable ratio of slenderness of the strut as a
 whole, whichever is less ( see also Section 8 -).
     5.9.2 In no case shall the ends of the, strut be connected together with
  less than two rivets or bolts or their equivalent in welding, and there shall
  be not less than two additional connections spaced equidistant in the length
  of strut. Where the members are separated back-to-back, the rivets or
  bolts through these connections shall pass through solid washers or pack-
  ings, and where the legs of the connected angles or tables of the connected
-tees are 125 mm wide or over, or where webs of channels are 150 mm
  wide or over, not less than two rivets or bolts shall be used in each con-
  nection, one on line of each gauge mark.
                                          54
L-r_   .I.._      _.    .    -   i.*-..      ,,
                                                  I   ~.-.~--~-1_“1.   “__-_-   .   .   -“I...- ._.,...-...
                                                                                                         ._ .__--__ ^ ... ~..I
                                                                                                                            _-
                                                                                                   IS : 800.. 1984
                  5.9.3 Where these connections are made by welding, solid packings
               shall be used to effect the j jinting unless the members are sufficiently close
               together to permit welding, and the members shall be connected by weld-
               ing along both pairs of edges of the main components.
                  5.9.4 The rivets, bolts or welds in these connections shall be sufficient
                                                                                                                    SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                    LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
               to carry the shear force and moments, if any, specified for battened struts,
               and in no case shall the rivets or bolts be less than 16 mm diameter for
               members up to and including 10 mm thick, 20 mm diameter for members
               up to and including 16 mm thick; and 22 mm diameter for members over
               16 mm thick.
                     5.9.4.1 Compression members connected by such riveting, bolting or
               welding shall not be subjected to transverse loading in a plane perpendi-
               cular to the washer-riveted, bolted or welded surfaces.
                  5.9.5 Where the components are in contact back-to-back, the spacing
               of the rivets, bolts or intermittent welds shall not exceed the maximum
               spacing for compression members as given in 6.1.4 and 6.2.6 of IS : 816-
               1969.
                                          SECTION 6 DESIGN OF MEMBERS
                                              SUBJECTED TO BENDING
               6.1 General - The calculated stress in a member subjected to bending
               shall not exceed any of the appropriate maximum permissible stresses given
               in 6.2 for bending, 6.3 for bearing, 6.4 for shear and in 7.1 for the com-
               bination of stresses.
               6.2 Bending Stresses
                  6.2.1 Maximum Bending Stresses - The maximum bending stress in
               tension ( cbt, csr ) or in Compression ( cbO, es1 ) in extreme fibre calculated
               on the effective section of ‘a beam shall not exceed the maximum permis-
               sible bending stress in tension ( @bt ) or in compression ( cbO ) obtained
               as follows nor the values specified in 6.2.2, 6.2.3, 6.2.5 and 6.2.6, as
               appropriate:
                                            ,,,,t Or t,,,o - O*SSf,,.
                  6.2.2 Maximum Permissible Bending Comjressiae Stress in Beams and Channels
               with Equal Flanges - For an I-beam or channel with equal flanges bent
               about the axis of maximum strength ( X-X axis ), the maximum bending
               compressive stress on the extreme fibre calculated on the effective section
               shah not exceed the values of maximum permissible bending compressive
               stress, @,e, given directly in Table 6.1A or 6. lB, Table 6 1C or 6.1D and
               Table 6.1 E or 6. lF, as appropriate, for steels with yield stress fy of 250 MPa,
               340 MPa and 400 MPa, respectively.         For steels with yield stresses other
                                                                                                                                                                                                     .
 than those covered in Tables 6.1A to 6.1F, maximum permissible bending
 compressive stress shall be obtained in accordance with 6.2.3 and 6.24.
       NOTE -    Tables 6.1A to 6.1F have been derived in accordance   with 6a.3
   and 6.2.4.
       6.2.2.1   In Tables 6.1A to 6.1F:
                                                                                   SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                   LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
       D -    overall depth of beam;
       41  - depth   of web ( see 1.3 );
         1 = effective length of compression flange ( see 6.6 );
       ry = radius of gyration of the section about its axis of minimum
             strength (y-y axis );
       T-    mean thickness of the compression flange, is equal to the area
             of horizontal portion of flange divided by width; and
         t = web thickness.       .*
       For rolled sections, the mean thickness     is that given in appropriate
 Indian Standards.          *
      In case of   compound girders with curtailed flanges, D shall be taken
as the overall     depth of the girder at the point of maximum bending
moment, and T      shall be taken as the effective thickness of the compression
flange and shall   be calculated as:
       T = X1 x mean thickness of the horizontal portion of the compres-
           sion flange at the point of maximum bending moment. Coeffi-
           cient K1 is defined in 6.2.4.
   6.2.3    Maximum Permissible Bending Compressive Stress in Beams and Plate
Girders -    For beams and plate girders, bent about the axis of maximum
strength ( x-x axis ), the maximum bending compressive stress on the
extreme fibre, calculated on the effective section shall not exceed the
maximum permissible bending compressive stress gbOin MPa obtained by
the following formula:
      where
            f ob = elastic critical stress in bending, calculated in accordance
                   with 6.2.4 or by an elastic flexural-torsional       buckling
                   analysis, in MPa;
            fr - yield stress of the steel in MPa; and
             a ===a factor assumed as 1.4.
      Values of ebO as derived from the above formula         for some of the
Indian Standard structure1 steels are given in Table 6.2.
                                       56
                                                                                        IS : 800 - 1984
    TABLE    6.1A     MAXIMUM    PERMISSIBLE       BENDING STRESSES,                        mc ( MPn ),
                       IN EQUAL-FLANGE      I-BEAMS OR CHANNELS
                                       ( Clause 6.2.2 )
                          with fy     = 250 MPa,     :     > 2’0 or -$-    > 85
    Dl l-+
              8      10    12    14       16    18    20      25    30    35    40     50      60    80   100
                                                                                                                SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
    bY
L
      40     160    160   159   159      158   158   158      158   158   157   157    157    157   157   157
      45     159    158   157   157      156   156   156      155   155   155   155    155    154   154   154
      50     158    157   156   155      154   154   153      153   152   152   152    151    151   151   151
      55     157    155   154   153      152   151   150      149   149   148   148    148    148   147   147
      60     156    153   152   150      149   148   148      146   145   145   144    144    1$4   143   143
      65     154    152   150   148      147   145   144      143   142   141   140    140    139   139   139
      70     153    150   148   14       144   142   141      139   138   137   136    135    135   135   134
      75     152    148   145   143      141   139   138      136   134   133   132    131    130   130   129
      80     150    147   143   141      138   136   135      132   130   128   128    126    126   125   125
      85     149    145   141   138      136   133   132      128   126   124   123    122    121   120   120
      90     147    143   139   136      133   130   128      124   122   120   119    117    116   115   115
      95     146    141   137   133      130   128   125      121   118   116   114    112    111   110   110
     100     145    140   135   131      128   125   122      117   114   112   110    108    107   105   105
     110     142    136   131   127      123   119   116      111   107   104   102     99     98    96    95
      120    139    133   127   122      118   114   111      104   100    97     94    91     90    88    87
     130     137    130   124   118      113   109   106       99    94    90     88    84     82    80    79
      140    134    127   120   114      109   105   101       93    88    84     81    78     75    73    72
      150    132    124   117   110      105   100       96    88    83    79     76    72     69    67    65
      160    129    121   113   107      101    96    92       84    78    74     71    66     64    61    60
      170    127    118   110   104       98    93    88       80    74    69     66    62     59    56    55
      180    124    115   107   100       94    89       85    76    70    65     62    58     55    52    50
      190    122    113   104    97       91    86    82       73    66    62     58    54     51    48    46
      200    120    110   102    94       88    83       78    70    63    59     55    50     48    44    43
     210     118    108    99    92       86    80    76       67    60    56     52    47     44    41    40
     220     116    105    97    89       83    78       73    64    58    53     49    45     42    38    37
      230    113    103    94    87       80    75       70    62    55    51     47    42     39    36    34
      240    111    101    92    84       78    73       68    59    53    48     45    40     37    34    32
      250    109     99    90    82       76    70       66    57    51    46     43    38     35    32    30
      260    107     97    88    80       74    68       64    55    49    44     41    36     33    30    28
      270    106     95    86    78       72    66       62    53    47    43     39    35     32    28    26
      280    104     93    84       76    70    65       60    51    45    41     38    33     30    27    25
      290    102     91    82       74    68    63       58    50    44    39     36    32     29    25    24
      300    100     89    80       72    66    61       57    48    42    38     35    30     27    24    22
                                                      57
     TABLE    6.1B       MAXIMUM         PERMISSIBLE      BENDING STRESSES,                ubo ( MPa ),
                          IN EQUAL       FLANGE I-BEAMS OR CHANNELS
                                              ( &WS6 6.2.2 )
                            with   f y=    250 MPa, +2*Oand+               6 85
 D/T-
               8     10    12       14    16     18    20    25    30    35    40    50      60    80    100
                                                                                                                SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
     l/‘J
--
       40    161   161    160      160   160    160   160    159   159   159   159   159    159    159    159
       45    161   160    159      159   158    158   158    157   157   157   157   157     157   157    157
       50    160   158    158      157   156    156   156    155   155   155   154   154    154    154    154
       55    159   157    156      155    154   154   153    153   152   152   152   151     151   151    151
       60    158   156    154      153   152    152   151    150   149   149   149   148     148   148    148
      65     156   154    153      151   150    149   148    147   146   146   145   145    144    144    144
       70    155   153    151      149   149    147   146    144   143   142   142   141    141    140    140
      75     154   152     149     147   146    144   143    141   140   139   138   137    137    136    136
      80     153   150    148      145   143    142   140    138   136   135   134   133    132    132    132
      85     152   149    146      143   141    139   138    135   133   131   130   129    128    127    127
      90     151   147    144      141   139    137   135    131   129   127   126   125    124    123    123
      95     150   146    142      139   137    134   132    128   126   124   122   121    120    119    118
     100     149   145    141      137   134    132   129    125   122   120   118   116    115    114    113
     110     147   142    137      133   130    127   124    119   115   113   111   108    107    105    105
     120     144   139    134      129   126    122   119    113   109   106   104   101     99    97     96
     130     142   136    131      126   121    118   114    108   103   99    97    94      91    89     88
     140     140   133    128      122   118    113   110    103   97    94    91    87      85    82     81
     150     138   131    124      119   114    109   105     98    92    88   85    81      78    76     74
     160     136   128    121      115   110    106   ‘101   93    87    83    80    75      73    70     68
     170     134   126    119      112   107    102    98    89    83    79    75    70      68    64     63
     180     131   123    116      109   104    99     94    85    79    74    71    66      63    60     58
     190     129   121    113      106   101    95     91    82     75    71   67     62     59    55     54
     200     127   118    111      104    98    92     88    79    72     67   63    58      55    51     50
     210     125   116    108      101    95    90     85    76    69     64   60    55      52    48     46                                                                                     ,
     220     123   114    lC6      99     92    87     82     73   66    61    57    52      49    45     43
     230     122   112    103      96     90    84     80    70    63    58    55    49      46    42     40
     240     120   110    101      94     87    82     77    68    61    56    52    47      43    40     38
     250     118   108     99      92     85    80     75    65    59    54    50    44      41    37     35
     260     116   106     97      89     83    77     73    63    57    52    48    42      39    35     33
     270     114   104     95      87     81    75     71    61    55    50    46    41      37    33     31
     280     113   102     93      85     79    73    69     59    53    48    44    39      35    32     30
     290     111   100     91      84     77    72     67    58    51    46    42    37      34    30     28
     300     109   98      89      82     75    70     65    56    49    45    41    36      32    29     27
                                                      58
TABLE 6.1 C      MAXIMUM   PERMISSIBLE BENDING STRESSES, (Ibc ( MPa ),
                  IN EQUAL FLANGE I-BEAMS OR CHANkELS
                                            ( Ckme 6.2.2       )
                     withfy        = 340 MPa, f          >    2’0 or $-     > 75
D/T-+
          8     10    12      14      16     18     20        25    30     35      40    50     60    80    100
                                                                                                                   SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                   LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
eY+
   4Q    !15   214   212   212       211    211    210       210    209    209    209    209    209   209   209
   45    !13   211   209   208       207    206    206       205    204    204    204    203    203   203   203
   50    !10   208   205   204       203    202    201       199    199    198    198    197    197   197   197
   55    !08   204   202   200       198    197    196       194    193    192    191    191    190   190   190
   60    !05   201   198   195       193    191    190       188    186    185    185    184    183   183   183
   65    !03   198   194   191       188    186    185       181    180    178    177    176    176   175   175
   70    !OO 195     190   186       183    181    179       175    173    171    170    169    168   167   167
   75    I98   192   186   182       179    176    173       169    166    164    163    161    160   159   159
   80    195   188   183   178       174    170    168       163    159    157    156    154    153   151   151
   85    93    185   179   174       169    165    162       157    153    1.50 149      146    145   144   143
   90    90    182   175   169       165    161    157       151    147    144    142    139    138   136   136
   95    .88   179   172   165       160    156    152       145    141    137    135    132    131   129   128
  100    85    176   168   162       156    151    147       140    135    131    129    126    124   122   121
  110    .80   170   162   154       148    143    138       130    124    120    117    114    112   109   108
  120    .76   165   155   147       141    135    130       121    115    110    107    103    101    98    97
  130    171   159   149   141       134    128    122       113    106    101     98     93     91    88    87
  140    167   154   144   135       127    121    116       105     98     93     90     85     82    79    78
  150    163   150   139      l.29   122    115    110        99     92     87     83     78     75    72    70
  160    158   145   134      124    116    110    104        93     86     80     77     72     68    65    63
  170    155   141   129   120       111    105     99        88     80     75     71     66     63    59    58
  180    151   137   125      115    107    100     94        83     76     70     66     61     58    54    53
  190    147   133   121      111    103     96     90        79     72     66     62     57     54    50    48
  200    144   129   117      107     99     92     86        75     68     62     58     53     50    46    44
  210    140   125   113      103     95     88     83        72     64     59     55     50     46    43    41
  220    137   122   110      100     92     85     79        69     61     56     52     47     43    40    38
  230    134   119   107       97     89     82     76        66     58     53     49     44     41    37    35
  240    131   116   104       94     86     79     74        63     56     51     47     42     38    35    33
  .250   128   113   101       91     83     76     71        61     53     48     44     39     36    32    31
  260    125   110    98       88     80     74     68        58     51     46     42     37     34    31    29
  270    122   107    95      86      78     72     66        56     49     44     41     36     32    29    27
  280    120   105    93       83     76     69     64         54    47     42     39     34     31    27    25
  290    117   102    90       81     73     67     62        52     46     41     37     32     29    26    24
  300    115   100    88       79      71     65     60        51     44     39     36     31    28    25     23
                                                    59
1s : 806 - 1984
TABLE 6.1 D        MAXIMUM PERMISSIBLE BENDING STRESSES, (q,~ l4fPs ),
                   IN EQUAL FLANGE I-BEAMS OR CHANNELS
                                ( Ckru.w6.2.2 )
                     withfy        = 340 MPa,    T<    2’0 and +c         75
         8    10     12       14     16     18    20    25    30    35     40    50    60    80    100
                                                                                                          SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                          LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
  40   217   216    215    214      214    213   213   213   212    212    212   212   212   212   212
  45   215   214     212   211      211    210   210   209   208    208    208   208   208   207   20~
  50   213   211    209    208      207    206   206   205   204    203    203   203   203   202   207,
  55   211   209    206    205      203    202   201   200   199    198   198    197   197   197   197
  60   209   206     203   201       199   198   197   195   193    193    192   191   191   191   190
  65   207   203    200    197      195    193   192   189   188    187    186   185   184   184   184
  70   205   201     197   194      191    189   187   184   182    181    180   178   178   177   177
  75   203   198    194    190      187    184   182   178   176    174    173   172   171   170   169
  80   201   195    190    186      183    180   177   173   170    168    167   165   164   163   162
  85   199   193    187    183      179    175   173   168   164    162   160    158   157   156   155
  90   197   190    184    179      175    171   167   162   158    156    154   151   150   148   148
  95   195   187    181    175      171    167   163   157   153    150    148   145   143   142   141
 100   193   185    178    172      167    163   159   152   147    144   142    138   137   135   134
 110   188   180    172    165      159    155   150   142   137    133    130   126   124   122   121
 120   184   175    166    159      152    147   142   133   127    123   120    116   113   110   109
 130   180   170    161    153      146    140   135   125   119    114    110   106   103   100    99
 140   177   165    156    147      140    134   128   118   111    106    102    97   94    91     89
 150   173   161    151    142      134    128   122   112   104     99    95     89   86     83    81
 160   169   157    146    137      129    122   117   106   98     92     88    82    79    75     74
 170   166   153    142    132      124    117   111   100   92     86     82    76    73    69     67
 180   162   149    137    128      120    113   107    95    87    81     77    71    67    63     61
 190   L59   145    133    124      115    108   102    91   82      76    72    66    63    59     56
200    155   141    130    120      111    104   98    86    78     72     68    62    58    54     52
210    152   138    126    116      108    100   94    83     74    69     64    58    54    50    48
220    149   135    123    113      104     97    91   79    71     65     61    55    51    47    45
 230   146   132    119    109      101    94    88    76    68     62     58    52    48    44    42
240    143   128    116    106       98    91    85    73    65     59     55    49    45    41    39
 250   141   126    113    103       95    88    82    70    62     57     52    46    43    38    36
260    138   123    110    100       92    85    79    68    60     54     50    44    40    36    34
 270   135   120    108    98        89    82    77    65    58     52     48    42    38    35    32
280    133   117    105     95       87    80    74    63    56     50     46    40    36    32    30
290    130   115    103    93        84     78   72    61    54     48     44    38    35    31    29
300    128   112    100     90       82     76   70    59    52     46     42    37    33    29    27
                                                 60
                                                                                       ISr800-l!J84
  TABLE    6.1 E      MAXIMUM          PERMISSIBLE      BENDING STRESSES,                   Ubo ( -1,
                      IN EQUAL         FLANGE I-BEAMS OR CHANNELS
                                           ( Clausa 6.2 2 )
                         with   fy =   400 MPa, f        >    2.0 or +    > 67
D/l-+
                                                                                                              SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                              LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
            8      10    12      14     16    18    20        25    30    35     40   50       60       80   100
  “7
   40     250   248     247     245    245   244   243       243   242   242   242    241     241   241      241
   45     247   244     242     240    239   238   237       236   235   235   234    234     234   233      233
   50     244   240     237     234    233   231   230       228   227   227   226    226     225   225      225
   55     240   235     232     229    226   224   223       221   219   218   217    216     216   216      215
   60     236   231     226     223    220   217   216       212   210   209   208    207     206   206      205
   65     233   226     221     217    213   210   208       204   202   200   199    197     197   196      195
   70     229   222     216     211    207   203   201       196   193   191   189    188     187   186      185
   75     226   217     211     205    200   196   193       188   184   182   180    178     177   175      175
   80     222   213     206     199    194   190   186       180   176   173   171    168     167   166      165
   85     219   209     201     194    188   183   179       172   167   164   162    159     158   156      155
   90     216   205     196     188    182   177   173       165   160   156   154    151     149   147      146
   95     212   201     191     183    177   171   166       158   152   149   146    142     140   138      137
  100     209   197     187     178    171   165   160       151   145   141   138    135     133   130      129
  II0     203   189     178     169    161   155   149       139   133   128   125    121     118   115      114
  120     196   182     170     160    152   145   140       129   121   116   1!3    108     106   103      101
  130     191   176     163     153    144   137   131       119   112   106   103    98       95       92   90
  140     185   169     156     146    137   129   123       111   103    98     94    88      85       82   80
  150     179   163     150     139    130   122   116       104    96    90     86    81      77       74    72
  160     174   158     144     133    124   116   109       97    89    83     79     74      70       67    65
  170     169   152     139     127    118   110   104       92    83     78     73   68       64       61    59
  180     165   147     134     122    113   105    97       86     78    72     68   63       59       55   54
  190     160   143     129     117    108   100    94       82    74    68      64    58      55       51    49
 200      156   138     124     113    104    96    90        78    70    64    60    54       51       47   45
 210      152   134     120     109    100    92    86       74    66    60     56    51       47       43   41
 ?20      148   130     116     105     96    88    82        71   63    57      53   47       44       40   38
 230      144   126     112     101    92    85     79       67    60    54    50     45      41        37   36
 240      141   123     109      98    89     82    76       65    57    52    47     42       39       35   ‘33
 250      137   119     106     95     86    79     73       62    54    49    45     40      37        33   31
 260      134   116     103     92     83    76    70        60    52    47    43     38      35        31   29
 270      131   113     100     89     81    74    68        57    50    45    41     36      33        29   27
 280      128   110     97      86     78    71    66        55    48    43    39     34      31        27   26
 290      125   107     94      84     76    69    64        53    46    41    38     33      30    26       24
 300      122   105     92      82     74    67    62        52    45    40    36     31      28        25   m
                                                   61
IS t 888 - 1984
  TABLE     6.1 F      MAXIMUM         PERMISSIBLE BENDING STRESSES,                    abc ( MPa),
                       IN EQUAL       FLANGE I-BEAMS OR CHANNELS
                                             ( Clause 6.2.2 )
                          with   fy=    400 MPa, -+2.0and+C67
D/T+
hY          8     lo     12      14    16    18    20    25     30    35    40    50     60    80     loo
                                                                                                            SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                            LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
   4
  40      253    252    250   249     249   248   248   247     247   246   246   246    246   246    246
  45      251    248    246   245     244   243   243   242     241   241   240   240    240   240    239
  50      248    245    242   240     239   238   237   235     234   234   233   233    233   232    232
  55      245    241    238   236     234   232   231   229     227   227   226   225    225   225    224
  60      242    237    234   231     228   226   225   222     220   219   218   217    217   216    216
  65      239    234    229   225     222   220   218   215     212   211   210   209    208   207    207
  70      236    230    225   220     217   214   212   207     205   203   202   200    199   198    198
   75     233    226    220   215     211   208   205   200     197   195   193   191    190   189    188
  80      230    223    216   210     206   202   199   133, 189      186   185   182    181   180    179
  85      227    219    212   205     200   196   192   186     181   178   176   174    172   171    170
  90      225    215    207   201     195   190   186   179     174   171   168   165    164   162    161
  95      222    212    203   196     190   185   180   172     167   163   161   157    155   153    152
  100     219    208    199   191     185   179   175   166     160   156   153   150    148   145    144                                         .
  110     213    202    191   183     176   169   164   154     148   143   140   135    133   130    129
  120     208    195    184   175     167   160   154   144     136   131   127   123    120   117    115
 130      203    189    177   167     159   152   146   134     126   121   117   111    108   105    103
  140     198    183    171   160     152   144   138   126     117   111   107   102     98   95     93
 150      193    178    165   154     145   137   131   118     109   103    99    93     89    86     84
 160      188    172    159   148     139   131   124   111     102    96    92    85     82    78     76
  170     183    167    154   142     133   125   118   105      96    90    85    79     75    71     69
  180     179    162    149   137     127   119   112    99      90    84    79    73     69    65     63
  190     175    158    144   152     122   114   108    94      85    79    74   68      64   60      58
 200      171    153    139   128     118   110   103    90      81    75    70    63     60   55     53
 210      167    149    135   123     114   105    99    86      77    70   66    59      55   51     49
 220      163    145    131   119     110   102    95    82      73    67    62   56      52   48     45
 230      159    141    127   115     106    98    91    79      70    64   59    53      49   44     42
 240      156    138    123   112     102    94    88    75      67    61    56   50      46   42     39
 250      152    134    120   108      99    91    85    72      64    58   53    47     43    39     37
 260      149    131    117   105     96    88    82     70     61    55    51    45     41    37     34
 270      146    128    114   102      93    85    79    67     59     53   49    43     39    35     32
 280      i43.   125    111      99    90    83    77    85     57    51    47    41     37    33     30
 290      140    122    108      97    88    80   74     63     55    49    45    39     35    31     29
 300      137    119    105   94      85    78    72     61     53    47    43    37     3%    29     27
                                                  62
                                                                                                                                                                                             l
                                                                   IS t 800 - 1984
   6.2.4 Elastic Critical &ess - If an elastic flexural analysis is not carried
out, the elastic critical stressfOb for beams and plate girders with Ir smaller
than 1x shall be calculated using the following formula:
                                                                                  SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                  LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
where
              =    26.5 x IO’JMPa
         Y
                     ( 0% )’ -
         k1 -      a coefficient to allow for reduction in thickness or breadth of
                  flanges between points of effective lateral restraint and depends
                  on #, the ratio of the total area of both flanges at the point of
                  least bending moment to the corresponding area at the point of
                  greatest bending moment between such points of restraint.
                  Values of kl for different values of # are given in Table 6.3.
  D’pr$ -         as defined in 6.2.2.1.
   ,
         k, -     a coefficient to allow for the inequality of flanges, and depends
                  on W, the ratio of the moment of inertia ofthe compression
                  flange alone to that of the sum of the moments of inertia of the
                  flanges, each calculated about its own axis parallel to the y-y
                  axis of the girder, at the point of maximum bending moment.
                  Values of k, for different values of o are given in Table 6.4.
   Cl,   ca= respectively the lesser and greater distances from the section
                  neutral axis to the extreme fibres.
         I,   = moment of inertia of the whole section about the axis lying in
                the plane of bending ( axis y-y ), and
          Ix -    moment of inertia of the whole section about the axis normal
                  to the plane of bending ( x-x axis ).
      Values of X and Y are given in Table 6.5 for appropriate values of
 D/T and l/r,..
                                            63
                                                                                                                                     SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                                     LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
            TABLE      6.2    VALUES     OF mc CALCULATED         FROM feb FOR DIFFERENT           VALUES    OF fu
                                                                                                                                tf
                                                        ( Claw 6.2.3 )                                                          ..
                                                      All units in MPa.
                                                                                                                                8
                                                                                                                                I
    h +
           220   23 0        240   250    260   280   300   320    340    360   380   400    420     450    480   510     540
                                                                                                                                P
     20     13      13       13    13     13    13    13     13     13    13     13    13     13     13      13      13    13
     30     19      19       19    19     19    19    19     19     19     19    19    19     19      19     20      20   20
     40     25      25       25    25     25    25    25    2.5     26    26    26    26     26      26     26       26   26
     50     30      30       31    31     31    31    31    31      31    32    32     32    32      32      32      32   32
     60     36      36       36    36     36    37    37    37      37    37    3%     3%    3%      3%     3%       3%   3%
     7Q     41      41       41    41     42    42    42    43      43    43    43    .44    44      44     44       44   44
%    80     45    46         46    46     47    47    4%    4%      4%    4?I   49    49     49      50      50      50    50
     90    50     50         51    51     51    52    53    53     54     54    54    55     55      55     56       56   56
    100    54       54       55    55     56    57    57    5%      59    59    60    60     60      61     61       62   62
                                                                                                                                                                                                                      I
                                                                                                                                                                                                                      ,
     110   5%    5%          59    60     60    61    62    63      64    64    65    65     66      66     67       67   67                                                                                          /
     120   61    62          63    64     64    65    67    67      6%    69    70    70     71      71     72       72   73
     130    65      66       67    67     6%    70    71    72      73    74    74    75     76      76     77       7%   7%
     140    6%      69       70    71     72    73    75     76     77    7%     79    80    80      81     82       83   a4
     150    71      72       73    74     75    77    79     80     81    82    83     84    a5      a6     87       88   89
     160    74      75       77    7%     79    81    82    84      a5    87    88     89    90      91     92       93   94
     170    77    7%          80   81     82    84    86     8%     89    91     92    ;3    94      95     97       9%   99
     180    79    81         82    84     85    87    89    91      93    94    96    97     9%     100     101   102     103
     190   82     %k         85    87     a%    90    93    95     97     9%    100   1.02   102    104     106   107     10%
                                                                                                                       SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                       LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
        200   84    86    88    89    91    93    96    98    100   102   103   105   106   108   110   111    113
        210   86    88    90    92     93   96    ,99   101   103   105   107   109   110   112   114   116    117
        220   89    90    92    94    96    99    102   104   106   109   111   112   114   116   118   120    121
        230   90    93    94    96     98   101   104   107   110   112   114   116   118   120   122   124    126
        240   92    94    97    99    100   104   107   110   113   115   117   119   121   124   126   128    130
        250   94    96    99    101   103   106   110   113   115   118   120   122   124   127   130   132    134
        260   96    98    100   103   H)5   108   112   115   110   121   123   126   128   131   133   136    138
        270   97    100   102   104   107   111   114   118   121   124   126   129   131   134   137   139    142
        280   99    101   104   106   108   113   116   120   123   126   129   132   134   137   140   143    145
        290   100   103   lb5   108   110   115   119   122   126   129   132   135   137   141   144   147    149
        300   102   104   107   110   112   116   121   125   128   131   135   137   140   144   147   150    153
        310   103   106   108   111   114   118   123   127   130   134   137   140   143   147   150   153    156
    c   320   104   107   110   113   115   120   125   129   133   136   140   143   146   150   153   157    160
        330   105   108   111   114   117   122   126   131   135   138   142   145   148   152   156   160    163
        340   106   110   113   115   118   123   128   133   137   141   144   148   151   155   159   163    166
        350   108   111   114   117   12a   125   130   134   139   143   147   150   153   158   162   166    169
        360   109   112   115   118   121   126   131   136   141   145   149   152   156   161   166   169    172
        370   110   113   116   119   122   128   133   138   143   147   151   155   158   163   168   172    175
        380   111   114   117   120   123   129   135   140   144   149   153   157   160   166   170   174    178
        390   111   115   118   121   125   130   136   141   146   151   155   159   163   168   173   177    181
        400   112   116   119   122   126   i32   137   143   148   152   157   161   165   170   175   180    184
        420   114   118   121   124   128   134   140   146   151   156   160   165   169   175   180   185    189
              115   119   123   126   130   136   142   148   154   159   164   169   173   179   185   190    195
        440
                                                                                                        ( Continued)
l
                                                                                                                                                 SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                                                 LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                    TABLE    6.2     VALUES    OF U&. CALCULATED         FROM    f& FOR DWFERENT         VALUES     OF fy -   ~otthf
                                                                   All units in MPa.
                                                                                                                                             L
        fY     +
                       220     230       240   250   260    280    300    320    34@   3@l   380   400    420     450   480    510     540
         f?
             460       117     121       124   128   132    138    145    151    157   162   167   172    177     183   189     194    200
         -480          118     122       126   130   133    140    147    153    159   165   170   175    180     187   i93    199     204
             500,      119     123       127   131   135    142    149    155    162   168   173   178    183     190   197    203     209
             520       120     125       129   133   136    144    151    158    164   170   176   181    187     194   201    207     213
             540       121     126       130   134   138    145    153    160    166   172   178   184    189     197   204    211     217
             560       122         127   131   135   139    147    154    161    168   175   181   187    192     200   208    215     221
             580       123     128       132   136   140    148    156    163    170   177   183   i89    195     203   211    218     225
             600       124         129   133   137   141    150    157    165    172   179   185   192    198     206   214    222     229
    s        620       125         129   134   138   143    151    159    166    174   181   187   194    200     209   217    225     232
             6‘lo      126         130   135   139   144    152    160    168    175   183   189   196    202     211   220    228     235
             660       126         131   136   140   145    153    161     169   177   i84   191   198    204     214   222    231     238
             680       127         132   136   141   145    154    163    171    178   186   193   200    207     216   225    234     242
             700       128         132   137   142   146    155    164    172    180   187   195   202    209     218   228    236     244
             720       128         133   138   143   147    156    165    173    181   189   196   204    210     220   230    239     247
             740                                            157    166   ~ 174   182   190   198   205    212     222   232    241     250
                       129         134   139   143   148
             760                                                                             199   207    214     224   234    244     253
                       129         134   139   144   149    158    167    175    184   192
             780       130         135   140   145   149    159    168    176    185   193   201   208    216     226   236    246     255
             800       130         135   140   145   150    159    169    177    186   194   202   210    217     228   238    248     257
             850       131         137   142   147   152    161    171    180    188   197   205   213    221     232   243    253     263
             900       132         138   143   148   153    163    172    182    191   200   208   216    224     236   247    258     268
             950       133         138   144   149   154    164.   174     183   193   202   211   219    227     240   251    262     273
        Iooo           134         139   145   150   155~   165    175     185   195   204   213   222    230     243   255    266     277
.
                                                                                                                              SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                              LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
    1050         135    140   145   151   156   167    177   187   196   206   215   224   233   246   258   270   281
    1 100        135    141   146   152   157   168    178   188   198   207   217   226   235   248   261   273   285
    I 150        136    141   147   152   158   168    179   189   199   209   219   228   237   251   263   276   288
    1200         136    142   147   153   159   169    180   190   200   210   220   230   239   253   266   279   291
    1300         137    143   149   154   160   171    182   192   203   213   223   233   243   257   270   284   297
    1400         138    144   149   155   161   .172   183   194   205   215   225   236   246   260   274   288   302
    1500         139    144   150   156   162   173    184   195   206   217   228   238   248   263   278   292   306
    1600         139    145   151   157   163   174    185   197   208   219   229   240   250   266   281   295   309
    1 700        140    146   151   157   163   175    186   198   209   220   231   242   252   268   283   298   313
    ! 800        140    146   152   158   164   176    187   199   210   221   232   243   254   270   285   301   316
    1 900        140    146   152   158   164   176    188   200   211   222   234   245   256   272   287   303   318
    2 000        ‘141   147   153   159   165   177    189   200   212   223   235   246   257   273   289   305   321
2   2 200        141    147   154   160   166   178    190   202   213   225   237   248   259   276   292   309   325
    2 400        142    148   154   160   166   179    191   203   215   226   238   250   261   278   295   312   328
    2 600        142    148   154   161   167   179    191   204   216   227   239   251   263   280   297   314   331
    2 800        142    149   155   161   167   180    192   204   216   228   240   252   264   282   299   316   333
    3 000        143    149   155   161   168   180    193   205   217   229   241   253   265   283   300   318   335
    3 500        143    149   156   162   168   181    194   206   218   231   243   255   267   286   303   321   339
    4000         143    150   156   163   169   182    194   207   219   232   244   257   269   287   306   324   342
    4 500        144    150   157   163   169   182    195   208   220   233   245   258   270   289   307   326   344   t;
    5000         144    150   157   163   170   183    195   208   221   233   246   259   271   290   309   327   346   ”
    d 500        144    151   157   163   170   183    196   208   221   234   247   259   272   291   310   328   347   0
    6 0‘00       144    151   157   164   170   183    196   209   222   234   247   260   273   291   310   329   348   &
             I
                                                                                                                         g
                                                                                                                      _.._“.,--.7-                    II=‘   -m...-   .
*.“,   /,   “l.*.*_^,“.                c_J,I,l~**.“--“I_L._I
       IS I 809 - 1984
                          TABLE         6.3                VALUES       OF k, FOR BEAMS          WITH        CURTAILED               FLANGES
                                                                                ( Clause 6.2.4   )
                          (1,    1.0                  0.9         0’8     0.7     0’6     0.5          0’4      0.3          0.2        0.1     0’0
                    kl           I.0                   1-O        1’0     0.9     0’8     0.7          0.6      0.5          0’4        0’3     0’2
                              NOTE -                   Flanges should not be reduced          in breadth to give a value of + lower
                          than 0.25.
                                                                                                                                                                          SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                                                                          LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                               TABLE          6.4              VALUES    OF kp FOR BEAMS             WITH     UNEQUAL                FLANGES
                                                                                ( Clause 6.2.4   )
                          0       1’0                    0’9      0’8     0.7     0.6     0’5          0.4      0.3          0.2        0’1     0.0
                          k,      0.5                    0’4      0.3     0.2     0’1     0          -0.2     -0.4    -0.6            -0.8    -1.0
                  6.2.4.1 Values of fob shall be increased by 20 percent when T/t is
            not greater than 2-O and d,/t is not greater than 1 3441 qf; where dl is as
            defined in 6.2.2.1 and 1.3 and t the thickness of web.
                               NOTE - Guidance for calculqting                          elastic buckling         forces may be found in the
                          references listed in Appendix E.
           6.2.5 Beams Bent About the Axis of Minimum Strength ( y-y axis ) - The
        maximum permissible bending stress in tension u,-,t or in compression CQO
        in beams bent about t,he axis of minimum strength shall not exceed
        @66 f,,, where f y is the yield stress of steel.
               6.2.6 Angles and Tees - The bending stress in the leg when loaded with
            the flange or table in compression shall not exceed O-66f ,,. When loaded
            with the leg in compression,      the permissible bending stress shall be
            calculated from 6.2.3 and 6.2.4 with k8 = - l-0 and I = thickness of leg.
            6.3 Bearing Stress -The     bearing stress in any part of a beam when
            calculated on the net area of contact shall not exceed the value of up
            determined by the following formula:
                                                                                bp = 0.75        fy
                           where
                                                   bp = maximum permissible bearing stress, and
                                                   fY = yield stress of steel.
            6.4 Shear Stresses
               6.4.1 Maximum Shear Stress - The maximum shear stress in a member
            having regard to the distribution of stresses in conformity with the elastic
            behaviour of the member in flexure, shall not exceed the value 7vm given
            below: ~
                                                                                        68
                                                                                           r&s: 800 - 1984
   where
                rym = maximum             permissible           shear stress, and
                  f,. =     yield stress of steel,
   6.4.2 Average Shear Stress - The average shear stress in a member
calculated on the cross section of the web ( see 6.4.2.1 ) shall not exceed:
                                                                                                                  SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                  LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
      a) For unst$ened webs -               the   value          rVa obtained          by      the    formula
          rva = 0.4 f,, and
     b) For sti$ened webs - the values given in Tables 6.6A, 6.6B and 6.6C
        as appropriate    for yield stress values 250, 340 and 400 MPa,
        respectively.
           The values rya for stiffened webs for a steel whose yield stress is
              not given in Tables 6.6A, 6.6B and 6.6C shall be determined
              by using the following formulae,      provided that the average
              stress rVQ, shall not exceed O-4 f,,.
                 i) For webs where the distance                      between    the vertical         stiffeners
                    is less than ‘d’
                                                  zoi
                                                       -         c
                                                           .-
                  TVS   =    0.4fy
                                     [
                                          le3
                                            -                        1+ 4      (;)‘)
                                                                                           1
                ii) For webs where the distance                      between    the vertical stiffeners
                    is more than ‘d’
                 %a = 0.4fr              1.3 _
   where
     rva = maximum permissible average shear stress.
     c   = distance between vertical stiffeners.
     d     =
               1) For vertically sti$ened webs without horizontal stgeners - the clear
                  distance between flange angles or, where there.are no flange
                  angles, the clear distance between flanges, ignoring fillets.
                  Where tongue plates ( see Fig. 6.1 ) having a thickness of
                  not less than twice the thickness of the web plate are used,
                  the depth d shall be taken as the depth of the girder between
                  the flanges less the sum of the depths of the tongue plates or
                  eight times the sum of the thickness of the tongue plates,
                  whichever is less.
                                                  69
                                                                                                                                                               _-
                                                                                                                                                                             SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                                                                             LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                                                 TABLE      6.5    VALUES        OF x AND Y FOR CALCULATING                 f&
                                                                                  ( Clam 6.2.4 )
                                                                                                                                                               -    __I
            DIT                                                                           X                                                                         r        ’
                                                                                                                                                                    -5:
                                                                                                                                                               1
        h        +
        \   +         8         10          12       14           16       18      20      25        30     35       40      50         60       80     100                  $
                                                                                                                                                                    -
            40       !484       2222       2066     1965      1897       1849     1814    1759      1728    1709    1697    1683       1675    1.667   1663        1 656
            45       ! 103      1856       1708     1612      1546       1499     1465    1411      1380    1362    1349    1335       1327    1319    1315        1 309
            50       1822       1590       1449     1357      1293       1248     1214    1161      1131    1113    1101    1086       1078    1070    1067        1 060
            55       1 607      I389       1254     1 166     1 105      1061     1028     976       947     929     917     902        894     886     883         876
            60       1 437      1 232      1 104    1 020         961     918      886     835       806     788     776     762        754     746     743         736
            65       1 301      1 107       985      904          847     806       775    726       697     679     667     653        645     637     634         627
            70       1 188      1 005        889      811         757      717     687     638        610    592     581     567        559     551     547         541
    2       75       1 094        920        810      735         682      644     615     567       540     522     511     497        489     481     478         471
            80       1 014       849         743      672         621      584      556    509        482    465     454     440        432     424     421         414
            85        945         788        687      618         570      533     506     461        434    417     406     392        385      377    373         367
            90        886         735        639      573         526      491     464     420        394    377     366     353        345     337     334         327
            95         833        689        597      534         488      454      428    385        360    343     332     319        311     304     300         294
            100        787        649        560      499         455      423      398     356       331     314     304    290        283      275    272         265
            110        708        58“        499      443         402      371      317    307        283    268     257     244        237     229     226         219
            120        644        527        451      398         359      330      308     270       247     232     222        209     202     194     191         184
            130           591     482        411      361         325      298      277       240     218     204     194        181     174     167     163         157
            140           546     444        378      331         297      271      251     217       195     181     172        160     153     145     142         135
            150           508     412        350      306          274     249      230       197     177     163     152        142     135     145     124         118
            160           474        385     326      284          254     230      212       181     161     148     139        127     121     113     110         104
            170           445        360      305      265         236      214     197       167     148     135     126        115     109     102     98             92
            180           420        339     286       249         221      200     184       155     137     125     116        105      98      92     88             82
.
                                                                                                      SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                      LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
190   397   320   270   235   208   188   172    145   127   115   107   96   90   83   80   1   73
200   376   304   256   222   197   177   162    136   119   107   99    89   83   76   73       66
210   358   288   243   210   186   168   153    128   112   101   93    82   76   70   66       60
220   341   275   231   200   177   159   145    121   105   94    87    77   71   64   61       55
230   32;   262   220   191   169   152   138    115   99    89    82    72   66   60   56       50
240   312   251   211   182   161   145   132    109   94    84    77    67   62   55   52       46
250   299   241   202   175   154   138   126    104   90    80    73    64   58   52   49       42
260   288   231   194   167   148   133   12 1    99   85    76    69    60   55   48   45       39
270   277   222   186   161   142   127   116    95    82    72    66    57   52   46   42       36
280   267   214   180   155   137   122   111    91    78    69    63    54   49   43   40       34
290   257   207   173   149   132   118   107    88    75    66    60    52   46   41   38       32
300   249   200   167   144   127   114   103    84    72    64    57    49   44   38   35       2g
_lS:808-1984
           2 ) For vertically s@ened webs with horizontal sti$eners - as describ-
                ed in 6.7.4.3, the clear distance between the tension flanges
                ( angles, flange plate or tongue plate ) and the horizontal
                stiffener.
          t = the thickness of the web.
                                                                                              SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                              LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                NOTE 1 - For the minimum thickness         of web plates and the design
            of web stiffeners, see 6.7.3 and 6.7.4.
                 NOTE 2 - The allowable stresses given in the Tables 6.6A, 6.6B and
            6.6C apply provided any reduction of the web cross section is due only to
            rivet holes, etc. Where large apertures are cut in the web, a special analysis
            shall be made to ensure that the maximum permissible average shear stresses
            laid down in this standard are not exceeded.
                 NOTE 3 - Compliance     with this subclause shall be deemed to satisfy the
            requirements of 6.4.1.
       6.4.2.1   The cross sections of the web shall be taken as follows:
      For rolled I-beams           and      The depth of the beam multiplied by
        channels                              web thickness
      For plate girders                        The depth of the web plate multi-
                                                 plied by its thickness
                            FIG.   6.1   TONQUE     PLATES
                                          72
t,
                          .             .=“ll..___.....
t----“‘--          “’
                               1                                _,.“.^.-1-,_-.
                                                                                                                I   _   .,-...   _^I^.    .l_-_---._.._                  ..-_.
                              TABLE 6.6A  PERMISSIBLE AVERAGE &EAR STRESS 7va
                                IN STIFFENED WBBS OF STEEL WITH fy = 250 MPa
                                                                                           ( C1au.r~
                                                                                                   6.4.2 )
             dlt         STRESS rva ( MPa ) BORDIFFERENTDISTANCESc BETWEENSTIFFENERS
                                                                                                                                                                                 SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                                                                                 LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                   _ __--___------~_*                    --_----_--_-_--_
                   ‘0*3d   0’4d    0’5d 0.6d 0’7d 0'8d 0.9d      I’Od l.ld 1’2d 1.3d 1*4d
             zi
            100
                        100
                        100
                        100
                                   100
                                   100
                                   100
                                                          100
                                                          100
                                                          100
                                                                :::
                                                                100
                                                                                     looloo
                                                                                     100
                                                                                     100
                                                                                                100
                                                                                                100
                                                                                                          100
                                                                                                          100
                                                                                                          100
                                                                                                                    100
                                                                                                                    100
                                                                                                                    100
                                                                                                                                         100
                                                                                                                                         100
                                                                                                                                         100
                                                                                                                                                          100
                                                                                                                                                          100
                                                                                                                                                          100
                                                                                                                                                                100
                                                                                                                                                                ‘9”:
                                                                                                                                                                        100
                                                                                                                                                                        ‘:
            105         100        100                    100   100                  100        100       100       100                  100               99    98       97
            110         100    100                        100   100                  100        100       100           100              99                      96      95
                        100    100                        100   1oc                  100        100       100                                             z:
            ::;         100    100                        100   100                  100        100       100           100
                                                                                                                         98              2:               95     :;     ;“;
            125         100    100                        100   100                  100        100        98            97              95               93     92     91
            130         100                                                                                                                                      :I     87
                                                                                                                                                                        69
            135         100    :“o:                       :z    100                  100
                                                                                     100        ::                      z:               z;               z:
                        100    160’                       100   100                   99                                                                  89
            ::          100    loo                        100   100                   97        ;:                      ::               ::               86     8847    tf
                        100                                                                               89                                              83     81     80
            :;x         100    :!8                        loo
                                                          100      98                94         t:                      ::               :;
            180         100    100                         98      2:                92         87        ::            82               80               z      :z      :f
            190         100    100                         97      92                :!I        84
            200         100        100                    95        90               86         82
            210         100         99                              88               83         sl
            220         100                                         86                      801
            230         100        tt                     90
                                                          ,“;       84               ;:
                                                                                            I                                                             Non-applicable ione.
            240         100        95                     88         83
            250         100                                                           ::
            260         100        z:                     t5”       ::           -
            270          99        90                     84        81           I
                        NOTE -           Intermediate values may be obtained by linear interpolation.
                                                                                                     73
                                                                                                                                                                                                                        ‘
       TABLE 6.6 B    PERMISSIBLE AVERAGE SHEAR T,,,, IN STIFFENED
                       WEBS OF STEEL WITH fu = 340 MPa
                                        ( C1m.w6.4.2         )
 0          SPRESA~,,a ( MPa ) BOR DIFFERENTDISTANCESc BETWEENSTIFFENEREI
       ~---------               F__-h___--             _____      -------~
                                                                                                            SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                            LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
       -0.3d      0’4d 0’5d 0’6d   0*7d 0’8d 0’9d 1’Od l’ld  l*Zd     1’3d 1*4d 1’5d
 75    136    136   136   136     136       136       136                           136       136    136
 8”:   :3”6
              136
              136
                    136   136     136       136       136        ::Fi136
                                                                     136
                                                                              136
                                                                              136   136       136
                                                                                              134
                                                                                                     136
                                                                                                     133
                    136   136     136       136       136        136    136   136   136
 90    136    136   136   136     136       136       136        136    136   135   133       132    131
1:;    136    136   136   136               136       136        136    135   133   131       129    128
              136   136           :iz                 136        135
105    136    136   136   :t:     136       :z        135        133    132
                                                                        130   130
                                                                              128   128
                                                                                    126       :2”;   ::3”
110    136    136   136   136     136       135       133        131    128   ;;;   124       122    120
115    136    136   136   136     136       133       131        129    126         121       119    118
ii0    i%     136   136           135       131       129        127    124   121   119       117    115
125    136    136   136   :Ei     133       129       127        125    121   119   116       114    113
130    136    136   136   135     131       127       125        122    119   116   114       ;;;    Hz
135    136    136   136   134     129       126       123        120    117   114   111
140    136    136   136   132     127       124       121        118    115   112   109       107    105
150    136    136   135   129     124       120       117        114    110   107   104       102    100
160    136    136   132   126     120                            110                                  95
170
180
       136
       136
              136
              135   ET
                          123
                          119
                                  117
                                  113
                                            tt2”
                                            108
                                                      ::9”
                                                      105
                                                                 106
                                                                 102
                                                                        E97 lo2
                                                                             98
                                                                             93
                                                                                gg
                                                                                95
                                                                                90
                                                                                   3:
                                                                                   87                 ::
190    136    133   124   116     110       105       100
200    136    130   121   113     106       101   96
              128   118   110     103        97 -
s:“o   136    126   116   107      99        93 I
230    135    123   113   103      96   -                              Non-applicable zone.
              121   110
2: E‘i
260    130
              119
              116
                    107
                    104
270    128    114   102
        NOTE-Intermediate       values may be obtained by linear interpolation.
                                                 74
                                                                                                                                                                                             .
                                                                                                     ts : 690- 19a4
              TABLE 6.6 C PERMISSIBLE AVERAGE  SHEAR STRESS 7va
                 IN STIFFENED WEBS OF STEEL WITH fy = 460 MPa
                                                  ( Clause6.42 )
 d/t          STREW       TV*   (MPa ) FOR DIFFERENT DISTANCES c BETWEEN STIFFENERS
       r------------                               *_----__-------__-_~
                                                                                                                      SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                      LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
         0*3d      0’4d     0*5d   0’6d 0*7d 0’8d  0*9d     I’Od     IOld i’2d I’3d 1’4d 1’5d
 70     160      160       160      160     160        160        160       160      160     160      XX       ;;;   160
 75     160      160       160      160     160        160        160       160      160     160                     159
                           160      160     160        160        160       160      160     160      159      157   156
                           160      160     160        160        160       160      160     158      156      154   152
 ;;     160      160        160     160     160
                                            160        160        159
                                                                  160       157
                                                                            160       157
                                                                                      154    155      152
                                                                                                      149      147
                                                                                                               151   149
                                                                                                                     146
100     160      160        160     160     160                   157       155       151    :::      146      144   143
105     160      160        160     160     160        1’Z        154       152       149    146      143      141   139
110
115    160       160       160      160
                                    ::“9    159
                                            156        155
                                                       152        152
                                                                  149       ;;;      ;;;     143
                                                                                             140      fZ       138
                                                                                                               135   ‘36
                                                                                                                     133
120    160       160       160              154                   147       144      ;40     137      134      132   129
125    160       160       160      157     152        t:;        144       141      137     134      131      128   126
130    160       :::       160      155     150    145            141       139      134    131      128       125   123
135    160                 160      153     147    143            139       136      132    128      125       122   120
140    160       160       158      151’    145    140            136       133      129    125      122       119   116
150    160       160       155      147     141    135            131       128      123    119      115       112   110
160    160       160       151      143     136        130        126       123      117     113     109       106   103
180
170    160       155
                 158       144
                           148      135
                                    139     127
                                            132     E             116
                                                                  121       112
                                                                            117      106
                                                                                     112    101
                                                                                            107       97
                                                                                                     103        93
                                                                                                               100   Zl
190    160       152       140      131     123     116           111
                                                                                                                      -
200    160       149       137      127     118        111     106      I
7in     ifx      14li
                 ---       133      123     114        106    I------
220
___    157
       _-_       143       i30      il9     109        101    1
230    155       140       126      114     105   I-
                                                                                    Non-applicable     zone.
240
-..
2.50
       153
       ii1
                 137
                 134
                           123
                           119
                                    110
                                    106
                                            100
                                             96
                                                  I1
         NOTE -        Intermediate        values may be obtained                 by linear interpolation.
                                                             75
k,                  ._.             __. . --.
     1s   I   806 - 1984
     6.5 Effective Span of Beams - The effective span of a beam shall be
     taken as the length between the centres of the supports, except in cases
     where the point of application of the reaction is taken as eccentricity to
     the support, when it shall be permissible to take the effective span as the
     length between the assumed points of application of reaction.
     6.6 Effective Length
                                                                                                 SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                 LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                                  of Compression       Flanges
        6.6.1 For simply supported beams and girders where no lateral
     restraint of the compression flanges is provided, but where each end of the
     beam is restrained against torsion, the effective length ‘ 1 ’ of the
     compression ,flanges to be used in 6.2 shall be taken as follows:
               a ) With ends of compression      flanges unrest-        1 = span
                    rained against lateral bending ( that is,
                    free to rotate in plan at the bearings )
               b)   With ends of compression flanges partially          1 = O-85 X span
                    restrained against lateral bending ( that is,
                    not free to rotate in plan at the bearings )
              Cl With       ends of compression flanges fully           1 = 0.7 X span
                    restrained against lateral bending ( that is,
                    not free to rotate in plan at the bearings )
              Restraint against torsion can be provided by:
                      i) web or flange cleats, or
                      ii) bearing stiffeners acting in conjunction with the bearing of
                           the beam, or
                    iii) ‘lateral end frames or other external supports to the ends of
                           the compression flanges ( see Note below ), or
                    iv) their being built in to walls.
            Where the ends of the beam are not restrained against torsion, or
     where the load is applied to the compression flange and both the load and
     flange are free to move laterally, the above values of the effective length
     shall be increased by 20 percent.
               NOTE - The end restraint element shall be capable of safely resisting, in
          addition to wind and other applied external forces, a horizontal force acting at the
          bearing in a direction normal to the compression flange of the beam at the level of
          the centroid of the flange and having a value equal to not less than 2.5 percent of
          the maximum force occurring in the flange.
        6.6.2 For beams which are provided with members giving effective
     lateral restraint to the compression flange at intervals along the span, in
     addition to the end torsional restraint required in 6.6.1 the effective length
     of the compression flange shall be taken as the maximum distance, centre-
     to-centre, of the restraint members.
                                                76
                                                                                                                                                                                  .
                                                                       IS   rmo - 1984
    6.6.3 For cantilever beams of projecting length          ‘ L ’ the effective length
( 1 ’ to be used in 6.2 shall be taken as follows:
     4    Built-in   at the support,   free at the end                 I = 0.85       L
     b)   Built-in   at the support,  restrained     against            1 = 0.75      L
          torsion at the end by continuous     construction
                                                                                                  SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                  LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
          ( see Fig. 6.2A )
      Cl Built-in    at the  support,   restrained against              1 = 0.5       L
          lateral deflection and torsion at the free end
          ( see Fig. 6.2B )
      4   Continuous at the support, unrestrained  against              1=3L
          torsion at the support and free at the end
          ( see Fig. 6.2C )
      e) Continuous    at the support with         partial restraint      1=2L
          against  torsion   of the support        and free at the
          end ( see Fig. 6.2D )
      f 1 Continuous    at the support,          restrained against         l=L
          torsion at the support and             free at the end
          ( see Fig. 6.2E )
      bT =length     of cantilever
     If there is a degree      of fixity at the free end, the effective      length       shall
be multiplied by
       0.5
       oT5    in (b) and (c) above,       and by Gin          (d), (e) and ( f) above.
   6.6.4 Where     beams     support    slab construction,   the beam     shall be
deemed to be effectively       restrained   laterally if the frictional or positive
connection   of the slab to the beam is capable of resisting a lateral force of
2.5 percent of the maximum force in the compression flange of the beam,
considered    as distributed    uniformly    along the flange. Furthermore,     the
slab construction   shall be capable of resisting this lateral force in flexure
and shear.
    6.6.5 For beams which are provided        with members       giving effective
lateral restraint of the compression flange at intervals along the span, the
effective lateral restraint shall be capable of resisting a force of 2.5 percent
of the maximum force in the compression       flange taken as divided equally
between the number of points at which the, restraint members occur.
    6.6.6 In a series of such beams, with solid webs, which are connected
 together by the same system of restraint members, the sum of the restraining
 forces required shall be taken as 2 percent of the maximum     flange force
 in one beam only.
                                            77
                                                            SUPPLIED BY BOOK SUPPLY BUREAU
                                                            LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
FICL 6.2A   CANTILEVERBUILT-IN
                             AT SUPPORT,RESTRAINEDAGAINST
                     TORSIONATTHE END
  FIG.6.2B CANTILEVERBUILT-IN AT SUPPORT,RESTRAINED
                LATERALLY AT THEEND
                          78
                                                                                    SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                    LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
    FIG. 6.2C CANTILEVERL,                   FIG. 6.2D CANTILEVERIa
   CONTINUOUSAT THE SUPPORT,                CONTINUOUSAT THE SUPPORT,
  UNRESTRAINEDAGAINSTTORSION               PARTIALLYRESTRAINEDAGAW~T
AT THE SUPPORTAND UNRESTRA~NBD              TORSIONAT THE SUPPORTAND
            AT THE END                         UNRESTRAINED
                                                          AT THE END
                                                                      TIONS
                                                      AT INTERSECTIONS
    Fro. 6.2E  CANTILEVERSPAN CONTINUOUSAT THE SUPPORT,FULLY
            RESTRAINEDAQAINSTTORSIONAT THE SUPPORTAND
                   UNRESTRAINBDAT THE FREE END
       6.6.6.1 In the case of a series of latticed beams, girders or roof trusses
 which are connected together by the same system of restraint members,
 the sum of the restraining forces required shall be taken as 2b5 percent
 of the maximum force in the compression flange plus l-25 percent of this
 force for every member of the series other than the first up to a maximum
 total of 7.5 percent.
                                        79
L.
     6.7 Design     of Beams   and Plate Girders    with Solid Webs
        6.7.1 Sectional Projerties - Solid web girders should preferably          be
     proportioned on the basis of the moment of inertia of the gross~ cross
     section with the neutral axis taken at the centroid of that section, but it
     shall be permissible to use the net moment of inertia.     In arriving at the
     maximum flexural stresses, the stresses calculated on the basis of the gross
     moment of inertia shall be increased in the ratio of gross area to effective
                                                                                       SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                       LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
     area of the flange section, For this purpose the flange sectional area in
     riveted or bolted construction shall be taken to be that of the flange plate,
     flange angles and the portion of the web and side plates ( if any ) between
     the flange angles; in welded construction the flange sectional area shall be
     taken to be that of the flange plates plus that of the tongue plates ( if any )
     up to a limit of eight times their thickness, which shall be not less than
     twice the thickness of the web. **
           6.7.1.1 The effective sectional area of compression flanges shall be
     the gross area with d.eductions for excessive width of plates as specified for
     compression members ( see 3.5.2.1 and 3.5.2.2 ) and for open holes ( inclu-
     ding holes for pins and black bolts ) occurring in a plane perpendicular to
     the direction of stress at the section being considered ( see 3.6 ).
            The effective sectional area of tension flanges shall be the gross
     sectional area with deductions for holes as specified in 3.5.2.1 and 3.6 of
     this Code.
            The effective sectional    area for parts in shear   shall be taken   as
     specified in 6.7.3.4.
        6.7.2   Flanges
           6.7.2.1 In riveted or bolted construction, flange angles shall form as
     large a part of the area of the flange as practicable ( preferably not less
     than one-third ) and the number of flange plates shall be kept to a
     minimum:
            a>Inplateexposed  situations where
                       of the top flange shall
                                                flange plates are used, at least one
                                               extend the full length of the girder,
                unl,ess the top edge of the web is machined flush with the flange
                angles. Where two or more flange plates are used on the one
                flange, tacking rivets shall be provided, if necessary, to comply
                with the requirements of 8.10.2 and 8.10.3.
           b)   Each flange plate shall be extended beyond its theoretical cut-off
                point, and the extension shall contain sufficient rivets or welds to
                develop in the plate the load calculated for the bending moment
                on the girder section ( taken to include the curtailed plate ) at
                the theoretical cut-off point.
                                            80
--.                                _.    ,..-._.-._- “_,-._.I_.., . .       “_,
                                                                                   xs:8oo-1984
            c) The outstand\ of flange plates, that is the projection beyond the
               outer line of connections to flange angles, channel or joist flanges,
               or, in the case of welded constructions, their projection beyond
               the face of the web or tongue plate, shall not exceed the valueb
               given in 3.5.2.
            d) In the case of box girders, the thickness of any plate, or the
               aggregate thickness of two or more plates when these plates are
                                                                                               SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                               LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
               tacked together to form the flange, shall satisfy the requirements
               given in 3.5.2.
            6.7.2.2 Flange splices - Flange joints preferably should not be
      located at points of maximum stress. Where splice plates are used, their
      area shall be not less than 5 percent in excess of the area of the flange
      element spliced, their centre of gravity shall coincide, as nearly as possible,
      with that of the element splfced.’ There shall be enough rivets or welds on
      each side of the splice to develop the load in the element spliced plus 5
      percent but in no case should the strength developed be less than 50
      percent of the effective strength of the material spliced. Xn welded
      construction, flange plates shall be joined by complete penetration butt
      welds, wherever possible. These butt welds shall deveIop the full strength
      of the plates.
            6.7.2.3 Connection of jlanges to web - The flanges of plate girders shall
      be connected to the web by sufficient rivets, bolts or welds to transmit the
      maximum horizontal shear force resulting from the bending moments in
      the girder, combined with any vertical loads which are directly applied to
      the flange.
             6.7.2.4 Disbersion of load through JIange to web - Where a Ioad is
      directly applied to a top flange, it shall be considered as dispersed
      uniformly at an angle of 30 degrees to the horizontal.
         6.7.3   Web Plates
            6.7.3.1 Minimum thickness -        The thickness of the web plate shall be
      not less than the following:
            a) For unstiffened webs: the greater of
                                                              -
                              4 2/ Tvap cam and “;_&$_-                 but not less than i.
                                   816
                  where
                              dl = depth of web as defined in 1.3, and
                     %a,   cal =   calculated average stress in the web due to shear
                                   force.
                                                 81
                                                                                                                                                                                .
rsrsoo-1984
     b)   For vertically    stiffened    webs: the greater         of
          l/180 of the smallest clear panel dimension
          and     d   y’-
                  -!-_&     but not      less than    -&-
                                                       200
                                                                                                      SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                      LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                    3 200
     4    For webs stiffened     both  vertically  and horizontally     with a
          horizontal   stiffener  at a distance from the compression     flange
          equal to 2/5 of the distance from the compression       flange to the
          neutral axis: the greater of
          l/l80   of the smaller    dimension        in each panel,
           and    da
                  _ V~       but not less than &
                   4 000
     4    When there is also a horizontal              stiffener        at the neutral      axis of
          the girder: the greater of
           l/180 of the smaller         dimension    in each panel,
           and    !!6?&&      but not less than         -%
                                                        400
     In (b), (c) and (d) above, dz is twice the clear distance from the
     compression flange angles, or plate, or tongue plate to the neutral
     axis.
           In the case of welded crane gantry plate girders intended                            for
     carrying    cranes  with a lifting load of 15 tonnes or more,                              the
     thickness of web plate shall be not less than 8 mm.
          The minimum thickness of web plates for different                         yield    stress
     values are given in Table 6.7 for information.
      NOTE- In no case shall the greater clear dimension of a web panel exceed
  270 f, nor the lesser clear dimension of the same panel exceed 180 t, where t is
  the thickness of the web plate.
      6.7.3.2 Riveted construction - For girders  in exposed situations and
which do not have flange plates for their entire length, the top edye
of the web plate shall be flush with or above the angles, as specified ‘o;-
the engineer, and the bottom edge of the web plate shall be flush with or
set back from the an;Tles, as specified by the engineer.
      6.7.3.3 Welded construction -- The gap between the web ;llatc’s and
flange plates shall be kept to a minimum,    and for fillet weld:; .shall not
exceed 1 mm at any point before welding.
                                              82
                                                                                                                                                                                       .
                                                                                                                                          SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                                          LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                                            l’ABLE   6.7 MINIMUM        THICKNESS      OF WEB
                                                            ( Clause 6.7.3.1 )
                                    Minimum     Thickness of Web for Yield Stressfy ( in MPa ) of
     y-------_-_____                                 ---_-h-____,                                          --                         ,
     fY           220   230   240     250     260    280     300  320 340   360    380   400  420         450      480   510    540
                                                            ds
                                                           -----   dr     ds     da                           ds    de
                                                           185     (79    174    169                      -ialp
    d,&y          ds    ds    ds       da      4      da    da     j’e_ &        Js_    &     4,    ds        dr    4     ds     4
    4ooo         zz     250   250     %Y       248   239   %l      224    217    211   ‘205   %%    195   x        183   -i??   172
z   drcy         dp      dz    da      da       dt    da   _&_     5       ds          dt      ds   A_    de        d,   j-a_   pI
                                                                                 da
    6 400        &)-    400   hoo     -@%-     396   382   370     358    348    338   328    320   312    302     292    284   276
      6.7.3.4   E$ctive sectionalarea
      a) Web of #ate girder - The effective cross-sectional area shall be
         taken as the full depth of the web plate multiplied by the
         thickness.
              NOTE -Where     webs are varie in thickness in the depth of the section
         by the use of tongue plates or the Ii e, or where the proportion of the web
                                                                                        SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                        LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
         included in the flange area ia 25 pert
                                            “%, t or more of the overall depth, the
         above approximationis not permissible&nd the maximum shear stress shall
         be computed.
      b) Rolled beam.rand channels - The effective cross-sectional area for
         shear shall be taken as the full depth of the beam or channel
         multiplied by its web thickness. For other sections the maxi-
         mum shear stress shall be computed from the whole area of the
         cross section, having regard to the actual distribution of shear
         stress.
      c) Webs which have openings larger than those normally used for
         rivets or other fastenings require s cial analysis to ensure that
         the permissible stress as specific % in this standard are not
         exceeded.
       6.7.3.5 Splices in webs -“Splices in the webs of the plate girders and
rolled sections shall be designed to resist the shears and moments at the
spliced section.
      In riveted construction, splice plates shall be provided on each side
of the web. In welded construction, web splices shall preferably be made
with complete penetration butt welds.
       6.7.3.6 Where additional plates are re.quired to augment the strength
of the web, they shall be placed on each side of the web and shall be
equal in thickness.   The proportion of shear force, assumed to be resisted
by these plates shall be limited by the amount of horizontal shear which
they can transmit to the flanges through their fastenings, and such re-
inforcing plates and their fastenings shall be carried beyond the points
at which they become theoretically necessary,
  6.7.4   Intermediate Web Sti$cnersfor Plate Girders,
       6.7.4.1 General - When the thickness of the web is less than the
limits specified in 6.7.3.1 (a) vertical stiffeners shall be provided through-
out the length of the girder.     When the thickness of the web is less than
the limits specified in 6.7.3.1 (b) horizontal stiffeners shall be provided in
addition to the vertical stiffeners.
      In no case shall the greater unsupported clear dimension of a web
Dane1 exceed 270 t nor the lesser unsupported clear dimension of the .same
panel exceed 180 t, where t is the thickness of the web plate.
                                        84
       6.7.4.2  Vertical ,sti$eners - Where vertical stiffeners are required, they
shall be provided throughout the length of the girder at a distqce apart
not greater than l-5 d and not less than 0*33 d, where d is the depth as
defined in 6.4.2 ( definition 1 ). ‘Where horizontal stiffeners are provided
d in mm shall ‘be taken as’the clear distance between the horizontal
stiffener and the tension flange ( farthest flange ) ignoring fillets. These
vertical stiffeners shall be designed so that I is not !ess than
                                                                                     SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                     LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                                       ds -x ts
                              -. l-5 x 7
      where
           I = the moment of inertia of a pair of stiffeners about the
                centre of the web, or a single stiffener about the face of the
                web,
            t = the minimum required thickness of the web, and
             c = the maximum permitted           clear   distance between     vertical
                 stiffener for thickness t.
        NOTE- If the thickness of the web is made greater, or the spacing of stiffeners
  made smaller than that required by the atandard, the moment of inertia of the
  stiffener need not be correspondingly increased.
      Intermediate vertical stiffeners may be joggled and may be single or
in pairs placed one on each side of the web. Where single stiffeners are
used, they should preferably be placed alternatively on opposite sides of
the web. The stiffeners shall extend from flange to flange, but need not
have the ends fitted to provide a tight bearing on the flange.
      6.7.4.3 Horizontal sti$eners - Where horizontal stiffeners are used in
addition to vertical stiffeners, they shall be as follows:
      4   One horizontal stiffener shall be placed on the web at a distance
          from the compression flange equal to 215 of the distance from the
          compression flange to the neutral axis when the thickness of the
          web is less than the limits specified in 6.7.3.1 (b). This stiffener
          shall be designed so that I is not less than 4c.ts where I and t
          are as defined in 6.7.4.2 and c is the actual distance between the
          vertical stiffeners;
      b) A   second horizontal stiffener ( single or double ) shall be placed
          at the neutral axis of the girder when the thickness of the web ‘is
          less than the limit specified in 6.7.3.1 (c). This stiffener shall be
          designed so that I is not less than ds.ts where ds also in mm, I
          and t are as defined in 6.7.4.2 and ds is as defined in 6.7.3.1;
      Cl Horizontal  web stiffeners shall extend between vertical stiffeners
          but need not be continuous over them; and
     4    Horizontal stiffeners may be in pairs arranged           on ‘each side of
          the web, or single.
                                         85
IS t 806 - 1984
           6.7.4.4     Outstand of sti$eners -  Unless thesouter edge of each stiffener
is   continuously        stiffened,   the outstand of all stiffeners from the web shall
                                 256~
be not more             than -            for sections and 12 t for flats where t is the
                                                                                           SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                           LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                                 4fF
 thickness of the section or flat.
      6.7.4.5 External forces on intermediate sti$eners - When vertical inter-
mediate stiffeners are subjected to bending moments and shears due to
eccentricity of vertical loads, or the action of transverse forces, the moment
of inertia of the stiffeners given in 6.7.4.2 shall be increased as shown
below:
           a) Bending moment on stiffener due to eccentricity of vertical loading
              bith respect to the vertical axis of the web:
               increase     of I =      150MDacm4., and
                                          Et
           b) Lateral loading on stiffener:
                                      0.3 VDS
               Increase of I =           Et   - cm4
                                               ,
           where
                     M = the applied bending moment,          KNm;
                      D =   overall depth of girder, in.mm;
                      E = Young’s modulus, 2 x 10s MPa;
                       t = thickness of web, mm; and
                      V = the transverse force in KN to be taken by the stiffener
                           and deemed to be applied at the compression flange of
                           the girder.
        6.7.4.6 Connections of intermediate sti&zers to web - Intermediate
 vertical and horizontal stiffeners not subjected to external loads shall be
connected to the web by rivets or welds, so as to withstand a shearing
force, between each component of the stiffener and the web of not less
than
           where
                     t = the web thickness in~@rn,‘and
     *l’             h = the outstand of stiffener in mm.
      For stiffeners subjected to external ,loads, the shear between the web
and stiffeners due to these loads shall be added to the above values.
                                                   86
                                                                               IS : 800 - 1984
   6.7.5 Load Bearing Web St$eners
      6.751 All sections - For any section, load bearing         stiffeners
shall be provided at points of concentrated load ( including points of
support ) where the concentrated load or reaction exceeds the value of
                                              aa~.z.B
     where
                                                                                                    SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                    LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
         aa     =     the maximum          permissible      axial   stress   for   colunins   as
                     given under 5.1 for a slenderness ratio $-LIT
              t = web thickness;
              B = the length of the stiff portion of the bearing plus the addi-
                   tional length given by dispersion at 45’ to the level of the
                   neutral axis, pIus the thickness of the stating angle, if any.
                   The stiff portion of a bearing is that length which cannot
                  deform appreciably in bending and shall not be taken as
                   greater than half the depth of beam for simply supported
                  beams and the full depth of the beams continuous over a
                  bearing; and
               dl = clear depth of web between root E”:ts.
      Load bearing           stiffeners shall be symmetrical          about the web, where
possible.
        6.7.5.2 Plate girders - ,Tn addition to the requirements of 6.7.5.1,
load bearing stiffness shall be prsvided also at the supports where
either:
     a) the web is overstressed in shear [ see 6.7.3.1                 (a)], or
     b) the web is otherwise                 overstressed     at support or at the web
        connection.
     6.7.5.3        Design   of load   bearing stijhers
     a) Load bearing stiffeners shall be designed as columns assuming the
        section to consist of fhe pair of stiffeners together with a Iength
        of web on each side of the cenere line of the stiffeners and equal,,
        where available, to 20 .times the web thickness.       The radius of
        gyration shall be taken about the axis parallel to the web of the
        beam or girder, and the working stress shall be in accordance
        with the appropriate allowable value for a compression member
        assuming an effective length equal to O-7 of the length of the
        stiffeners;
                                                 87
                                                                                               ‘.
                                                                                                                                                                                     .
       b)    The outstanding legs of each pair-of stiffeners shall be so propor-
            tioned that the bearing stress on that part of their area clear of
            the root of the flange or flange angles or clear of the welds does
            not exceed the bearing stress specified in 6.3;
            Stiffeners shall be symmetrical about the web, where possible and
                                                                                   SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                   LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
            at points of support shall project as nearly as practicable to the
            outer edges of the flanges;
       4    Load bearing stiffeners shall be provided with sufficient rivets
            or welds to transmit to the web the whole of the concentrated
            load;
       e)   The ends of load bearing stiffeners shall be fitted to provide a
            tight and uniform bearing upon the loaded flange unless welds or
            rivets designed to t#ansmit the full reaction or load are provided
            between the flange and stiffener. At points of support this require-
            ment shall apply ,at both flanges;
      f > Bearing stiffeners shall not be joggled and shall be solidly packed
        throughout; and
      EC)For plate girders, where load bearing stiffeners at supports are the
        solemeans of providing restraint against torsion ( see 6.6.4 ) the
         moment of inertia, 1, of the stiffener about the centre line of the
        web plate, shall be not less than
                                      DST       R
             where
                     D -   overall depth of the girder,
                     f -   maximum thickness of compression flange,
                     R = reaction of the beam at the support, and
                     W -   total load on the girder between supports.
       In addition, the bases of the stiffeners in conjunction with the bear-
ing of the girder shall be capable of resisting a moment due to the horizon-
tal force specified in the Note under 6.6.1.
6.8 Box Girders - The design and detailing of box girders shall be such
as to,give, full advantage of its higher load carrying capacity. The diaph-
ragms and horizontal stiffeners should conform to 6.7.3 and 6.7.4.
   6.8.1 All diaphragms shall be connected such as to transfer the resultant
shears to the web and flanges.
   6.8.2 Where the concentrated or moving load does not come directly on
top of the web, the local effect shall be considered for the design of flanges
and the diaphragms.
                                        88
6.9 Purlins
   6.9.1 All purlins shall be designed in accordance with the requirements
for undsed bean& ( see 6.2.1 and Table 3.1 ), and the limitations of
bending stress based on lateral instability of the compressicn flange and
the limiting deflection specified under 3.13 may be waived for the design
                                                                               SUPPLIED BY BOOK SUPPLY BUREAU
                                                                               LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
of purlins.   The maximum fibre stress shall not exceed the values
specified in 6.2.1 except as provided under 3.9 for increase of stress.
The calculated deflections should not exceed those,permitted for the type
of roof cladding used. In calculating the bending moment advantage may
be taken of the continuity of the purlin over supports. The bending
stresses about the two axes should be determined            separately and
checked in accordance with 7.1.1.     Open web purlins shall be designed as
trusses.
   6.9.2 Angle @urlins of steel copforming to Grades Fe 410-O. Fe 410-S or
Fe 4 10-W and slofies not exceeding,3@’ Pitch - As an alternate to the general
design procedure given in 6.9.1 angle purlins of roofs with slopes not
exceeding 30 degrees may be designed, if the following I :quirements which
are based on a minimum imposed load of 0.75 kN/ms are fulfilled:
     4    The width of leg or the depth of the purlin in the plane
          appropriate to the incidence of the maximum load or maximum
          component of the load is not less than L/45;
     b)   The width of     the other leg or width of the purlin is not less
          than L/60;
     C>The    maximum bending moment in a purlin may be taken as F
          where W is the total distributed load on the purlin including
          wind load. The loads shall be assumed as acting normal to the
          roof in which case the bending about the minor axis may be neg-
          lected. L shall be taken as distance centre-to-centre of the rafters
          or other supports of the purlins; and
     4    Under the bending moment calculated as in (c)‘above, the maxi-
          mum fibre stress shall not exceed the appropriate vahre of gb,r or cbt
          given in 6.2 except as provided under 3.9 for increase of stresses.
          The calculated deflection should not exceed those permitted for
          the type of cladding used.
6.10 Side and End Sheeting Rails - Side and end sheeting rails shall be
designed for wind pressures and vertical loads, if any; and the require-
ments of, as regards limiting deflection and lateral stability of beams, the
same provisions as given in 649.1 shall apply.
                                      89
18 : 800 - 1984
                  SECTION      7 COMBINED                       STRESSES
7.1 Combination     of Direct          Stresses
   7.1.1 Combined Axial ,Compression and Bending - Members subjected to
axial compression and bending shall be proportioned to satisfy the follow-
ing requirements:
                                                                                                   SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                   LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
     However, if the ratio ‘e                  ’ is less than 0.15, the following expres-
sion may be used in lieu of the above:
                    cat, 081. u”;.,“,“’               1 ““;;o;l-       6 1.(I
                             +
                     1 QBO
      The value of (2bCXand        to be used in the above formulae shall
                                @boy
each be lesser of the values of the maximum permissible stresses bbC given
in Section 6 for bending about the appropriate axis.
     b) At a suppbrt and using the values bbCxand obey at the support:
                    uac>Cal        @box,       081.
                                   ---+
                     0*6Of y+          flbox
     For   an’ encased      strut where               an allowance
                                                      is made for the force
                                                                   uac, OSl.
carried by the concrete in accordance with 10.1.1 the ratio of ----
                                                                      GAO
shall be replaced by the ratio of the calculated axial force on the strut to
the maximum permissible axial force determined as per 10.1.2.
   7.1.2 Combined Axial Tension and Bending -       A member subjected to both
axial tension and bending          shall be proportioned so that the following
condition is satisfied:
                    Uat, 081. ubtx> oal.                 %ty,      O&l.<   ]
                              ---+
                    O*60fY + 0*66fY,                     0.66 fv
   7.1.3 Symbols - The      symbols used in 7.1.1                     and 7.1.2   shall have the
following meaning:
   uao, 081. = calculated   average        axial compressive stress
   @at, Cal. - calculated   average        axial tensile stress
   ubc, 081. = calculated   bending        compressive stress in extreme fibre
   @bt. 081. = calculated   bending        tensile stress in extreme fibre
                                                 90
@a0           permissible axial compressive stress in the member              subject
              to axial compressive load only
              permissible axial tensile stress in the member subject               to
              axial tensile load only
              permissible bending compressive stress in extreme fibre
                                                                                    SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                    LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
ubo
flbt          permissible bending tensile stress in extreme fibre
                                                               GE
foo           elastic critical   stress in compression     -   --
                                                                As
              slenderness ratio in the plane of bending
%Y         = represent x-x and Y-y planes
c,         = a coefficient whose value shall be taken as follows:
              a) For     member in frames where side sway is not prevented:
                                 C, ‘5 0.85
              b) For members in frames where side sway is prevented and
                 not subject to transverse loading between their supports
                 in the plane of bending:
                        CDl e= 0.6 - 0.4 e 2 0.4
                       NOTE 1 - f3is the ratio of mallt-r to the larger moments at
                   the ends of that portion of the b braced member in the plane of
                   bending under consideration.
                        NOTE 2 - $ is positive yhen fhe member is bent in reverse
                   curvature and negative when It is bent in single curvature.
              c)   For members   in frames where Aide sway is prevented in,
                   the plane of loading and subjected to transverse loading
                   between their supports; the value of C, may be determin-
                   ed by rational analysis. In the absence of such analysis,
                   the following values may be used:
                   For members whose ends are restrained             against rotation
                         C,   = 0.85
                    For members whose ends are unrestrained against rotation
                        c, 5 1.00
   7.1.4 Bending and Shear - Irrespective of any increase in the germissi-
ble stress specified in 3.9, the equivalent stress ue, oer., due to co-e\xistent
bending ( tension or compression ) and shear stresses obtained from the
formula given in 7.1.4.1 shall not exceed the value:
                             be - 0.9f,
       where
           ~a p maximum permissible equivalent           stress.
                                        91
L.,.                                            _ -_-..i. _
             7.1.4.1 The equivalent stress ue, ,,ar. is obtained                    from the following
       formula:
                         @BPO&&l.
                               = debt*,               Cal* +   37Vma>
                                                                   081. Or
                                         =t/    ebo’, oal. + 37~12, oal.
                                                                                                         SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                         LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
           7.1.5 Combined, Bearing, Bending and Shear Stresses - Where a bearing
       stress is combined with tensile or compressive, bending and shear stresses
       under the most unfavourable         condition of loading,   the equivalent
       stress be, oal. obtained from the following formulae, shall not exceed
       Qe = 0*9f,.
                  Oe3   081.       =   dubt’,   ml* +     up’* oal* + ubt, osl. up, calm+ 3 Tvrn’,oal-
                  or           *
                  Qe, Or&l.-           d/Qboa, oal.   $   upa,
                                                            oal.   $ ubo, 081. up, oal. + 3T~rn2,cal.
        + 7.1.6 In 7.1.4 and 7.1.5 ubt, oa1.Gbbo, oar.; Tvm, oar. and up, oal.are the
       numerical values of the co-existent bending ( compression or tension ), shear
       and bearing stresses.       When bending occurs about both axes of the
       member, ubt. cal and ebC, oar. shall be,taken as the sum of the two calculat-
       ed fibre stresses. ue is the maximum permissible equivalent stress.
                                         SECTION          8 CONNECTIONS
       8.0 Ge era1 - As much of the work of fabrication as is reasonably
       practica le shall be completed in the shops where the steel work is
       fabricateB .
       8.1 Rivet&    Close Tolerance  Bolts,                       High Strength Friction    Grip
       Fasteners,;Black   Bolts and Welding                        - Where a connection is subject
       to impact or‘vibration or to reversal of stress ( unless such reversal is due
       solely to wind ) or where for some special reason, such as continuity in
       rigid framing or precision in alignment of machinery-slipping of bolts is
       not permissible! then rivets, close tolerance bolts, high strength friction
       grip fasteners or welding shall be used. In all other cases bolts in clearance
       holes may be used provided that due allowance is made for any
       slippage.
       8.2 Compositti Connections - In any connection which takes a force
       directly communicated to it and which is made with more than one type
       of fastening, only rivets and turned. and fitted bolts may be considered as
       acting together to share the load. In all other connections sufficient
       number of one type of fastening shall be provided to communicate the
       entire load for which the connection is designed.
                                                            92
                                                             IS:88811884
8.3 Members Meeting at a Joint - For triangulated frames designed
on the assumption of pin jointed connections, members meeting at a joint
shall, where practicable, have their centroidal axes meeting at a point; and
wherever racticable the centre of resistance of a. connection shall be on
the line o P action of the load so as to avoid an eccentricity moment on the
connections.
                                                                              SUPPLIED BY BOOK SUPPLY BUREAU
                                                                              LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
   8.3.1 However, where eccentricity of members or of connections is
present, the members a+ the connections shall provide adequate resistance
to the induced bending moments.
    8.3.2 Where the design is based on non-intersecting members at a joint
all stresses arising from the eccentricity of the members shall be calculated
and the stresses kept within the limits specified in the appropriate clause
of this code.
8.4 Bearing Brackets - Wherever practicable, connections of beams to
columns shall include a bottom bracket and top cleat. Where web cleats
are not provided, the bottom bracket shall be capable of carrying the
whole of the load.
8.5 Gussets - Gusset plates shall be designed to resist the shear, direct
and flexural stresses acting on the weakest or critical section. Re-entrant
cuts shall be avoided as far as practicable.
8.6 Packings
   8.6.1 Rivets or Bolts Through Packings- Number of rivets or bolts carrying
calculated shear through a packing shall be increased above the number
required by normal calculations by 2.5 percent for each 2.0 mm thickness
of packing except that, for packings having a thickness of 6 mm or less, no
increase need be made. For double shear connections packed on both
sides, the number of additional rivets or bolts required shall be determined
from the thickness of the thicker packing.    The additional rivets or bolts
should preferably be placed in an extension of the packing.
   8.6.2 Packings in Welded Construction - Where a packing is used between
two parts, the packing and the welds connecting it to each part shall be
capable of transmitting the load between the parts. Where the packing is
too thin to carry the load or permit the provlsion of ade uate welds, the
load shall be transmitted through the welds alone, the we1%s being increas-
ed in size by an amount equal to the thickness of the packing.
  8.663 Packing Subjected to Direct Compression only _- Where properly fitted
packings are subjected to direct compression only, the provisions
under 8.6.1 and 8.6.2 shall not apply.
                                     93
L
    IS t 888 - 1984
    8.7 Separators and Diaphragms - Where two or more rolled steel joists
    or channels are used side by side to form a girder, they shall be connected
    together at intervals of not more than 1 500 mm except in the case of gril-
    lage beams encased in concrete, where suitable provision shall be made to
    maintain correct spacing. Bolts and separators may be used provided that
                                                                                      SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                      LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
    in beams having a depth of 300 mm or more, not fewer than 2 bolts are
    used with each separator.    When loads are required to be carried from
    one beam to the other or are required to be distributed between the beams,
    diaphragms shall be used, designed with sufficient stiffness to distribute
    the load.
    8;8 Lug Angles
       8.8.1 Lug angles connecting a channel-shaped member shall, as far as
    possible, be disposed symmetrically  with respect to the section of the
    member.
       868.2 In the case of angle members, the lug: angles and their connec-
    tions to the gusset or other supporting member shall be capable of develop
    ing a strength not less than 20 percent in excess of the force in the
    outstanding leg of the angle, and the attachment of the lug angle to the
    angle member shall be capable df developing 40 percent in excess of that
    force.
       8i8.3 In the case of channel members and the like, the lug angles and
    thei’r connection to the gusset or other supporting member shall be cap-
    able of developing a strength of not less than 10 percent in excess of the
    force not accounted for by the direct connection of the member, and the
    attachment of the lug angles to the member shall be capable of developing
    20 percent in excess of that force.
       8.8;4 In no case shall fewer than two bolts or rivets be used for attach-
    ing the lug angle to the gusset or other supporting member.
       8.8.5 The effective conxiection of the lug angle shall, as far as possible
    terminate at the end of the member connected, and the fastening of the
    lug angle to the timber     shall perferably start in advance of the direct
    connection of the member to the gusset or other supporting member.
       8.8.6 Where lug angles are used to connect an angle member the whole
    area of the member shall be taken as effective notwithstanding the require-
    ments’of Section 3 and Section 5 of this code.
    8.9 Permissible    Stresses in Rivets and Bolts
       8.9.1 Calculation of Stresses - In calculating shear and bearing stresses
    the effective diameter of a rivet shall be taken as the hole diameter and
    that of a bolt as its nominal diameter.        In calculating the axial tensile
    stress in a rivet the gross area shall be used and in calculating the axial
    tensile stress in a bolt or screwed tension rod the net area shall be used.
                                          94
                                                                                 ISr808-1984
   8.9.2    Gross and Net Areas of Rivets and Bolts
     8.9.2.1 The gross area of a rivet shall be taken as the cross-sectional
area of the rivet hole.
      8.9.2.2 The net sectional area of a bolt or,screwed tension rod shall
be taken as the area of the root of the threaded part or cross-sectional area
                                                                                                   SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                   LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
of the unthreaded part whichever is lesser.
       NOTE-The    net sectional areas of bolts are given in IS : 1364-1967 and
   IS : 1367-1967.
   8.9.3 Area of Rivet and Bolt Holes - The diameter of a rivet hole shall be
taken as the nominal diameter of a rivet plus 1.5 mm for rivets of nominal
diameter less than or equal to 25 mm, and 2.0 mm for rivets of nominal
diameter exceeding 25 mm, unless otherwise specified. The diameter of a
bolt hole shall be taken as the nominal diameter of the bolt plus I.5 mm
unless specified otherwise.
   8.9.4 Stresses in Rivets, Bolts and Welds
      8.9.4.1 The calculated stress in a mild steel shop rivet or in a bolt of
property class 4.6 ( see IS : 1367-1967 ) shall not exceed the values given
in Table 8.1.
    TABLE     8.1    MAXIMUM       PBRMISSIBLE       STRESS    IN RIVETS         AND BOLTS    ~-
    DESORIPTION or              AXIAL TENSION, utf,         SEIEAR,        f,f     BEARING, up!
      FASTENERS
            (1)                         (2)                      (3)                   (4)
                                        Mpa                     MPa                   MPa
Power-driven rivets                      100                      100                   300
Hand-driven rivets                        80                       80                   250
Close   tolerance.  and                  120                      100                   300
  turned bolts
Bolts in clearance holes                 120                          80                250
      8.9.4.2 The permissible stress in a high tensile steel rivet shall be
those given in Table 8.1 multiplied by the ratio of the tensile strength
of the rivet material to the tensile strength as specified in IS : .I 148-1982
        NOTE -      For field rivets the permissible stresses shall be reduced by 10 percent.
       8.9.4.3 The permissible stress in a bolt ( other than a high strength
friction grip bolt ) of property class higher than 4.6 shall be those given
in Table 8.1 multiplied by the ratio of its yield stress or 0.2 percent
proof stress or 0.7 times its tensile strength, whichever is the lesser, to
235 MPa.
        8.9.4.4 The calculated bearing stress of a rivet or bolt on the parts
connected by it shall not exceed : (a) the valuef Y for hand driven rivets or
bolts in clearance holes, and (b) the value 1.2 f, for power driven rivets
or close tolerance and turned bolts. fy is the yield stress of the connected
parts.
                                               95
A‘                                                         .
     ISr80@- 1984
           Where the end distance of a rivet or bolt ( that is, the edge distance
     in the direction in which it bears ) is less than a limitfof twice the effec-
     tive diameter of the rivet or bolt, the permissible bearing stress of that
     rivet or bolt on the connected part shall be reduced in the ratio of the
     actual and distance to that limit.
            8.9.4:5 Combined shear and tension - Rivets and bolts subject to both
                                                                                           SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                           LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
     shear and axial tension shall be so proportioned that the shear and axial
     stresses calculated in accordance with 8.9.1   do not exceed the respective
     allowable stresses rVf and utf and the expression      WY OSl.‘    Rf, oa1.
                                                           -+---
                                                          I w              nf    1
     does not exceed 1.4.
           8.9.4.6 High strength friction grit bold - The provisions      contained
     in 8;9.4:1  to 8.9L4.5 do not apply to high strength friction grip bolts, which
     shall be used in conformity with I,S : 4000-1,967.
           8.9.4.7 Welds - Permissible    stress in welds shall be as specified in     ’
     IS : 816-1969 and IS : 1323-1982.
     8.10   Rivetsand Riveting
             Pitch
        8.10.1       of Rivets
            a) Minimum Pitch - The distance between centres of rivets should be
               not less than 2.5 times the nominal diameter of the rivet.
            b) Maximum Pitch
               i) The distance between centres of any two adjacent rivets
                  ( includ.ing tacking rivets ) shall not exceed 32 t or 300 mm,
                  whichever is less, where t is the thickness of the thinner
                  outside plate.
              ii) The distance between centres of two- adjacent rivets, in a line
                  lying in the direction of stress, shall not exceed 16 t or
                  200 mm, whichever is less in tension members and 12 t or
                  200mm, whichever is less in compression members. In the
                  case of compression members in which farces are transferred
                  through butting faces, this distance shall not exceed 4.5 times
                  the diameter of the rivets for a distance from the abutting
                  faces equal to 1.5 times the width of the member.
              iii) The distance between centres of any two consecutive rivets in
                   a line adjacent and parallel to an edge of an outside plate
                   shall not exceed (100 mm + 4 t ) or 200 mm, whichever
                   is less in compression or tension members.
              iv) When rivets are staggered at equal intervals and the gauge
                   does not exceed 75 mm, the distances specified in (ii) and
                   (iii) between centres of rivets, may be increased by 50
                   percent.
                                           96
                                                                 IS:rwo-1984
   8.10.2 Edge Distance
      4    The minimum distance from the centre of any hole to the edge of
           a plate shall be not less than that given in Table 8.2.
      b)   Where two or more parts are connected together, a line of rive&
           or bolts shall be provided at, a distance of not more than
           37 mm + 4 t from the nearest edge, where t is the thickness in
                                                                               SUPPLIED BY BOOK SUPPLY BUREAU
                                                                               LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
           mm of the thinner outside plate.      In the case of work not
           exposed to weather, this may be increased to 12 t.
                   TABLE 8.2   EDGE DISTANCE OF HOLES
   DIAXETER OF HOLE         DISTANCETO SHEAREDOR           DISTANCETO ROW,
                             HAND FLAME CUT EDGE           MACHINE FLAXE CUT,
                                                           SAWN OR PLANEDEDGE
           (1)                        (2)                           (3)
           mm                         mm                           mm
           13.5 and below              19                           17
           15’5                        25                           22
           17-5                        29                           25
           19’5                        32                           29
           21.5                        32                           29
           23.5                        38                           32
           25.5                        44                           38
           29-o                        51                           44
           32’0                        57                           51
           35-o                        57                           51
   8.10.3 Tacking Rivets - In cases of members covered under I).lO.l(b)(ii),
when the maximum distance between centres of two adjacent rivets
astspecified in 8.10.l(b)( ii ) is exceeded, tacking rivets not subjected to
calculated stress shall be used.
        8.10.3.1 Tacking rivets shall have a pitch      in line not exceeding
32 times the thickness of the outside plate or 300       mm, whichever is less.
Where the plates are exposed to the weather, the         pitch in line shall not
exceed 16 times, the thickness of the outside plate     or 200 mm, whichever
is less. In both cases, the lines of rivets shall not   be apart at a distance
greater than these pitches.
       8.10.3.2 All the requirements specified in 8.10.3.1 shall apply        to
compression members generally, subject to the stipuIation in this code
affecting the design and construction of compression members.
                                      97
IS:800    -1984
       8.10.3.3 In tension members composed of two flats, angles, channels
or tees in contact back-to-back    or separated back-to-back    by a distance not
exceeding the aggregate     thickness of the connected     parts, tacking rivets,
with solid distance pieces where the parts are separated, shall be provided
at pitch in line not exceeding 1 000 mm.
       8.10.3.4 For compression members covered in Section              5, the tacking
rivets shall be at a pitch in line not exceeding 600 mm.
                                                                                             SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                             LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
   8.10.4 Counterjunk Heads - For countersunk heads, one-half of the depth
of the countersinking   shall be neglected in calculating the length of the
rivet in bearing.  For rivets in tension with countersunk heads, the tensile
value shall be reduced by 33.3 percent.      No reduction need be made in
shear.
   8.10.5 Long Grip Rivets - Where the           grip of rivets carrying calculated
loads exceed 6 times the diameter of the        holes, the number of rivets required
by normal calculation shall be increased         by not less than one percent for
each additional 1.5 mm of grip; but the         grip shall not exceed 8 times the
diameter of the holes.
8.11   Bolts an-d Bolting
   8.11.1 Pitches, Edge Distances for Tacking Bolts - The requirements                 for
bolts shall be the same as for rivets given in 8.10 and its sub-clauses.
   8.11.2 Black Bo!ts - The       dimepsions     of black   bolts   shall   conform,   to
those given in IS : 1363-1967.
   8.11.3 (Jose   Tolerance   Bolts -   Close   tolerance   bolts   shall   conform    to
IS : 1364-1967.
   8.11.4 Turned Barrel Bolts - The nominal diameter of the barrel shall be
in multiples of 2 mm and shall be at least 2 mm larger in diameter than
the screwed portion.
   8.11.5  Washers - Washers with perfectly flat faces should be provided
with all close tolerance bolts and turned barrel bolts.  Steel or malleable
cast iron tapered washers shall be provided for all heads and nuts bearing
on bevelled surfaces.
   8.11.6 Locking of Nuts - Wherever there is risk of the nuts becoming
loose due to vibration or reversal of stresses, they shall be securely locked.
8.12 Welds and Welding - For requirements       of welds and welding,
reference shall be made to IS : 816-1969 and IS: 9595-1980.
                                           98
                                                               fS : so0 - 1984
                    SECTION        9   PLASTK     DESIGN
9.1 ,GeneraY
   9.1.1 The structure or part of a structure may be proportioned on the
basis of plastic design based on their maximum strength using the
provisions- contained in this section.    Reference may also be made to
SP (6) 6-1972.
                                                                                  SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                  LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
  9.1.2 The requirement of this standard regarding the maximum per-
missible stress shall be waived for this method.  However, the design shall
comply with all other requirements of this standard.
  9.13 Members subjected to heavy           impact   and fatigue shall not be
designed on the basis of plastic theory.
   9.1.4 Steel conforming to Grade Fe 410-O of IS : 1977-1975 shall not
be used when the structure is designed on the basis of plastic theory.
                                                1
9.2 Design
   9.2.X Load Factors - Structures or portions of structures proportioned
using plastic design shah have sufficient strength as determined by plastic
analysis to support the working loads multiplied by load factors as given
below:
                           Working Loads                    Load Factor,
                                                               Min
            Dead load                                           1.7
            Dead load +     imposed load                        1.7
            Dead load +    load due to wind or seismic          I.7
              forces
            Dead load +     imposed load + load due             l-3
              to wind or   seismic forces
  9.2.2 Dejection - Deflections under working loads shall be in accor-
dance with relevant provisions of this code.
  9.2.3    Beams
      9.2.3.1   The calculated maximum moment capacity, &I,,          of a beam
shall be
                                  Mp = &fv
      where
            &, 5 plastic modulus of the section, and
            f,, = yield stress of the material.
                                       99
                                                   _ ._     ._ ___..
                                                                   __...I
IS   I 888     -   1984
      9.2.3.2 Plastic properties of Indian Standard                                 medium weight beams
are given in Appendix F for information.
   9.2.4 Tension Members - The calculated maximum load capacity Pat of
a tension member shall be Pat = 0.85 AS&
         where
                                                                                                                 SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                 LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                   A, = effective cross-sectional               area of the member, and
                   f y=    yield stress of the steel.
   9.2.5 Struts -           The       calculated     maximum                load capacity P,,     of a strut
shall be
                                           P *,, =    1.7 A, sac
      where sac is the maximum permissible stress in axial compression as
given in 5.1 using an effective length 2 equal to the actual length L.
   9.2.6 Members Subjected to Combined Bending                                     and Axial Forces ( Beam-
Column Members )
      9.2.6.1 The calculated maximum moment capacity Mpe of a member
subjected to combined bending and axial forces, where PIP, exceeds 0.15,
shall be reduced below the value given in 9.2.3 and it shall satisfy the
following requirements:
         b)        Slender struts -A member where sin     addition to exceeding O-15
                                                      F
                                 l+P-ho     shall not be assumed to contain plastic
                   also exceeds l$-@n
                   hinges although it shall be permissible to design the member as
                   an elastic part of a plastically designed structure. Such a member
                   shall be designed according to the maximum permissible stress
                   requirements satisfying:
                                                                                    1.0
             c) Stocky struts -        A strut not covered                    in     (b) above   shall satisfy
                    P = an axial force, compressive or tensile in a member;
               MPG = maximum moment ( plastic ) capacity acting in the beam-
                     column;
                                                          100
                                                                                                                                                                                         .
                                                                      1S : 888 - 1984
        M r = plastic moment capacity of the section;
         M 0=     lateral buckling strength in the absence of axial load
                = M, if the beam column is laterally braced;
         P Bc = buckling strength in the plane of bending if axially loaded
                  ( without any bending moment ) and if the beam column
                                                                                        SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                        LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                  is laterally braced, as per 9.2.5.1;
          pe -    Euler load =     Fyt;s       for the plane of bending;
          Pr = yield strength of axially loaded section = As. f y;
          A s = effective cross-section area of the member;
         C,    = a coefficient as defined in 7.1.3;
              Y = radius of gyration about the same axis as the applied
                  moment;
           he = characteristic    slenderness ratio
                                 PyT= -.
                                  PO
                                      L
                                              ‘IET
                                                      z.
                                                      E ’
              B re ratio of end moment, each measured in the same rota-
                  tional direction and chosen with the numerically large
                  amount in the denominator       ( @ range from + 1 for
                  double curvature, 0 for one end pinned, to - 1 for single
                  curvature ) ; and
              L= actual strut length.
      9.2.6.2 A member assumed to contain plastic hinges and subjected
to combined b&ding and axial compression with PIPy not exceeding O-15
                                          0.6 + 0.4 p
shall have a value of PIP, not exceeding ---          where X0and p are as
                                                      A0
defined above.
   9.2.7 Shear - The calculated        maximum       shear capacity    Vr of a beam
or a beam-column shall be
                                 vv = 0.55 A, fy
      where A, is the effective cross-sectional area resisting shear for
calculating the average shear stress or the maximum shear capacity of the
members.
   9.2.8 Stabili~ - The elastic buckling load of a frame or its components
designed on the basis of plastic theory shall be at least three times the
plastic collapse load. If an accurate estimate of the elastic buckling load is
                                        101
                                                      .._-._“__._.
not available, this provision shall be deemed to be satisfied for frames of
up to three storeys if the compressive force P, in each member does not
exceed:
                                                                                                        SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                        LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
for ‘buckling in any direction,       where     the   effective      length   1 is determined
according to 5.2.
      For frames of over three storeys, the calculated                         plastic    collapse
load shall include an assessment of the moment caused                         by the      possible
combination  of high axial force and transverse deflection.
    9;2i9   Minimum Thickness
       9;2;9J Compression Outstands- A flange or other compression                         element
required to participate in a plastic hinge shall not project beyond                       its outer
most point of attachment   by more than 136. T,/df?
       Where Tl is the thickness of flange of a section                 or plate in compres-
sion or the aggregate thickness of plates if connected                  in accordance   with
Section 8.
      For the purpose of this clause, web stiffeners                  at plastic hinges         shall
be proportioned  as compression elements.
      9.2.9.2  lJn.q‘ported widths - The distance between adjacent parallel
lines of attachment      of a compression flange or another compression ele-
ment to other parts of member, when such flanges or elements are required
to participate   in a plastic hinge action, shall not exceed 512. Tl/+/ic
Where T1 is as defined in 9.269.1.
       9.2.9.3 Webs in shear -       If the depth dl of a web            subjected       to shear
                                                                            688.t
and required      to participate     in a plastic     hinge      exceeds   -=            then    the
                                                                              Jfp.
compressive    axial force P on the member            shall not exceed        the value
                     P =    P,    o*‘io-  +LL&
                               (                      )
       The maximum         permissible value of dl in &y plastic hinge zone shall
_   1120.t
      9.2.9.4 Web under bending and compression - When the web is subjected
to bending and compression,    the following conditions shall be satisfied:
       a) Where      2     exceeds     0.27,     then      the       depth     dl    shall        not
                     PV
            exceed
                                               102
      b) When       $       is less than or equal to O-27, then the depth dI shall
                                     )I.
                        ”
                              dfudfu
                                   (PY
                        s
                                  1120       1600         P   t
                              -          -   -           -
   9.2.10Lateral Bra&g
                                                                                                   SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                   LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
       9.2.10.1 Members shall be adequately braced to resist lateral and
torsional displacement at the plastic hinge locations associated with failure
mechanism.      Lateral bracing mass be dispensed within the region of the
last hinge to form in the failure mechanism assumed as the basis for
proportioning the given member.
             a) If the length along the member in which the applied
      9.2.10.2
                        moment           exceeds    O-85. M,,         is less than   or equal to
                        640v.rY
                              at least one critical flange support shall be pro-
                    -Tz     ’
                    vided within or at the end’of this length and the spacing
                    of the adjacent supports shall not exceed 96Ov.r,,/J fT
               b)   If the length along the member rn which the applied
                     moment exceeds 0.85 M, is greater than or equal to
                     64Ov.r,
                              the critical flange shall be supported in such a
                      Am-’
                    manner that no portion of this length is unsupported for
                    a distance of more than 9.
                                                                  Y
                c) Lateral restraints for the remaining elastic portions of
                   the member shall be designed in accordance with Sections
                   4 and 5 as appropiate, using ,stresses derived from the
                   plastic bending moments multiplied by 1.7.
     In this clause M, shall be assumed as Mp or MP0 as appropriate.
     v may be taken as unity or calculated by the following expression:
                                             1.5
                             ’ = dl          + (d/8)
       where e is the ratio of the rotation at the hinge point to the relative
elastic rotation of the far ends of the beam segment containing the plastic
hinge.
                                                   103
IS   I   890 - 1984
          NOTE - The lateral restraints provided by this clause will ensure that a section
     delivers its full moment and deformation capacity;     This may be too great for some
     design circumstances.    With the approval of the appropriate authority the design
     engineer may use the methods which allow a reduced amount of bracing to be used,
     provided that this reduction is justified by rational and widely accepted means and
     that any associated reductions in moment and deformation          capacity  are fully
                                                                                             SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                             LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
     considered in the design.
     9.2.11 Web Stifening
      9.2.11.1 Excessive shear forces - Web            stiffeners or doubler plates
shall be provided when the requirements of             9.2.7 are not met, in which
case the stiffeners or doubler plates shall            be capable of carrying that
portion of the force which exceeds the shear           capacity of the web.
       9.2.11.2 Concentrated loads - Web stiffeners shall be provided at
points on a member where the concentrated force delivered by the flanges
of another member framing into it will produce web crippling opposite
the compression flange or high tensile stress in the connection of the ten-
sion flange. This requirement shall be deemed to be satisfied if web
stiffeners are placed:
          a) opposite the compression flange of the other member when
                                            A!
                                     tCZ-,, + 5k
          b) opposite the tension flange of the other member when
                                      7-~<0~4.c/~~
          where
              t = thickness of web to be stiffened,
              k = distance from outer face of flange to web toe of fillet of
                  member to be stiffened,
            7-b = thickness of flange delivering concentrated load,
            7-r = thickness of flange of member to be stiffened, and
            Ai = area of flange delivering concentrated load.
                  The area of such stiffeners, Aa, shall be such that
                            A&Ax    - t ( lb + 5k )
       The ends of such stiffeners shall be fully butt welded to the inside
 face of the flange adjacent to the concentrated tensile force.       It shall be
permissible to fit the stiffeners against the inside face of the flange adjacent
to the concentrated compression force without welding.           When the con-
centrated force is delivered by only one beam connected to an outside face
0f.a strut, the length of the web stiffener shall extend for at least half the
depth of the member, and the welding connecting it to the web shall be
sufficient to develop a force off ,..A,t.
                                            104
                                                              IS : 800 - 1984
       9.2.11.3 Plastic hinges - Web stiffeners shall be provided at all
plastic hinges where the applied load exceeds 0.06 A, f ,,, where A, is as
explained in 9.2.7.
   9.2.12 Load Cabacities of Connections - The calculated load capacities of
welds, bolts and rivets shall be taken as l-7 times the values calculated
                                                                            SUPPLIED BY BOOK SUPPLY BUREAU
                                                                            LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
using permissible stress specified in 8.9.4.
9.3 Connections    and Fabrication
  9.3.1 Connections
       9.3.1.1 All connections which are essential to the continuity, assumed
as the basis of the design analysis shall be capable of resisting the moments,
shears and axial loads to which they would be subjected by either full or
factored loading.
       9.3.1.2 Corner connections    ( haunches ), tappered or curved for
architectural reasons shall be so proportioned that the full plastic bending
strength of the section adjacent to the connection may be developed.
      9.3.1.3 Stiffeners shall be used, as required, to preserve the flange
continuity of interrupted members at their junction with other members
in a continuous frame.        Such stiffeners shall be placed in pairs on
opposite sides of the web of the member which extends continuously
through the joint.
   9.3i2 Fabrication - The provisions of Section 11 with respect to work-
manship shall govern the fabrication of structures, or portions of structures,
designed on’ the basis of maximum strength, subject to the following
limitations:
       a) The use of sheared edges shall be avoided in locations subject to
           plastic hinge rotation at factored loading.   If used they shall be
           finished smooth by grinding, chipping or planing.
       b) In locations subject to plastic hinge rotation at factored loading,
           holes for rivets or bolts in the tension area shall be sub-punched
           and reamed or drilled full size.
         SECTION      10   DESIGN OF ENCASED            MEMBERS
10.1 Encased    Columns
   10.1.1 Conditions of Design - A member may be designed as an encased
column when the following conditions are fulfilled:
      a) The member is of symmetrical I-shape or a single I-beam for
         channels back-to-back, with or without flange plates;
                                      105
                                                                                                                                                             .
      b)   The overall   dimensions  of the steel section do not exceed
           750 x 450 mm over plating where used, the larger dimension
           being measured parallel to the web;
      4    The column is unpainted and is solidly encased in ordinary dense
           concrete, with 20 mm aggregate ( unless solidity can be obtained
                                                                                  SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                  LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
           with a larger aggregate ) and of grade designation     M 15, Min
           ( see IS : 456-1978 ).
     4     The minimum    width of solid casing is equal to 6e +      100 mm,
           where 6, k the width of the steel flange in millimetres;
      4    The surface and edges of the steel column    have a concrete   cover
           of not less than 50 mm;
      f)   The casing is effectively  reinforced   with steel wires.  The wire
           shall be at least 5 mm in diameter     and the reinforcement   shall
           be in the form of stirrups or binding at not more than 150 mm
           pitch so arranged as to pass through the centre of the c:overing
           of the edges and outer faces of the flanges and supported        by
           longitudinal  spacing bars not less than four in number; and
     g)    Steel cores in encased columns shall be accurately  machined    at
           splices and provisions  shall be made for alignment of column.
           At the column base provision shall be made to transfer the load
           to the footing at safe unit stresses in accordance with IS : 456-
           1978.
  10.1.2    Design   of   Member
       10.1.2.1  The steel section shall be considered as carrying the entire
load but allowance may be made by assuming the radius of gyration        ‘ I ’
of the column section about the axis in the plane of its web to be
0.2 (b, + 100) mm, where b, is the width of the steel flange in millimetres.
The radius of gyration about its other axis shall be taken as that of the
uncased section.
       1O.li2.2 The axial load on the encased column shall not exceed 2
times that which would be permitted on the uncased section, nor shall the
slenderness ratio of the uncased section ,for its full length centre-to-centre
of connections   exceed 250.
       10.L2.3    In computing the allowable axial load on the encased strut,
the concrete shall be taken as assisting in carrying   the load over its rec-
tangular    cross section, any cover in excess of 75 mm from the overall
dimensions of the steel section of the cased strut being ignored.
                                      106
     10.1.2.4The allowable compressive                       load P in case          of   encased
columns shall be determined as follows:
                                    P =    AsoQm +         A&
      where
                                                                                                    SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                    LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                 -%O, A, = cross-sectional area of steel and concrete, and
                 flBO>Qo = permissible stresses in steel and concrete in com-
                           pression.
       NOTE -      This clause does not apply        to steel struts of overall   sectional   dimen-
  sions greater than 1 000 mm x 500 mm, the dimension qf 1 000 mm being measured
  parallel    to the web or to box sections.
10.2 Encased Beams
   10.2.1Conditions of Design - Beams and girders with equal flanges may
be designed as encased beams when the following conditions are fulfilled:
      4 The section is of single web and I-form or of double open
         channel form with the webs not less than 40 mm apart;
      b)     The beam is unpainted and is solidly encased in ordinary ldense
             concrete, with 10 mm aggregate        ( unless solidity can be
             obtained with a larger aggregate ), and of a grade designation
             M 15, Min ( see IS : 456-1978 );
             The minimum width of solid caring = ( 6, + 100 ) mm, where
             b, is the width of the steel flange in mm;
             The surface and edges of the flanges of the beam have a concrete
             cover of not less than 50 ~-IQ; and
             The casing is effectively reinforced with steel wire of at least
              5 mm diameter and the reinforcement shall be in the form of
              stirrups or binding at not more than 150 mm pitch, and so
              arranged as to pass through the centre of the covering to the
              edges and soffit of the lower flange.
    10.2.2Design of Member - The steel section shall be considered as carry-
ing the entire load but allowance may be made for the effect of the con-
crete on the lateral stability of the compression flange.     This allowance
                                                                                                                                                                                         ,
should be made by assuming for the purpose of determining the permissi;
ble stress in compression that the equivalent moment of inertia ( Ir )
about the y-y axis is equal to A.r,S, where A is the area of steel section and
yYmay be taken as 0.2 ( be + 100 ) mm. Other properties required for
referring to 6.2 may be taken as for the uncased section. The permissible
bending stress so determined shall not exceed l-5 times that permitted for
 the uncased section.
       NOTE - This clause does not apply to beams and girders having a depth greater
   than 1 000 mm, or a width greater than 500 mm or to box sections.
                                               ?I?
                                                                                                                                                                                     .
IS t 888 - 1984
             SECTION        11    FABRICATION            AND ERECTION
 11.1 General - Tolerances      for fabrication   of steel structures shall
conform to IS : 72 15- 1974. Tolerances for erection of steel structures shall
conform to the Indian Standard.*       For general guidance on fabrication
by welding, reference may be made to IS : 9595-1980.
                                                                                 SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                 LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
11.2 Fabrication        Procedures
   11.2.1 Straightening - All material shall be straight and, if necessary,
before being worked shall be straightened and/or flattened by pressure,
unless required to be of curvilinear form and shall be free from twists.
   11.2.2 Clearances - The erection clearance for cleated ends of members
connecting steel to steel should preferably be not greater than 2-O mm at
each end. The erection clearance at ends of beams without web cleats
should be not more than 3 mm at each end, but where, for practical
reasons, greater clearance is necessary, suitably designed seatings should
be provided.
       11.2.2.1 Where black bolts are used, the holes may be made not
more than l-5 mm greater than the diameter of the bolts, unless otherwise
specified by the engineer.
   11.2.3   Cutting
      11.2.3.1   Cutting may be effected by shearing, cropping or sawing. Gas
cutting by mechanically controlled torch may be permitted for mild steel
only. Gas cutting of high tensile steel may also be permitted provided
special care is' taken to leave sufficient metal to be removed by machining
so that all metal that has been hardened by flame is removed.           Hand
flame cutting may be permitted subject to the approval of the inspector.
      11.2.3.2 Except where the material is subsequently joined by welding,
no loads shall be transmitted into metal throug,h a gas cut surface.
       11.2.3.3 Shearing,   cropping and gas cutting,    shall be clean,
reasonably square, and free from any distortion, and should the inspector
find it necessary, the edges shall be ground afterwards.
  11.2.4    Holing
      11.2.4.1  Holes through more than one thickness of material for
members, such as compound stanchion and girder flanges shall, where
possible, be drilled after the members are assembled and tightly clamped
or bolted together.    Punching may be permitted before assembly, provided
  *Tolerances    for erection of steel structures ( underprepurulion).
                                             108
                                                               lstmJ=1984
the holes are punched 3 mm less in diameter than the required size and
reamed after assembly to the full diameter. The thickness of material
punched shall be not greater than 16 mm. For dynamically loaded
structures, punching shall be avoided.
      11.2.4.2 When holes are drilled in one operation through two or
                                                                            SUPPLIED BY BOOK SUPPLY BUREAU
                                                                            LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
more separable parts, these parts, when so specified by the engineer, shall
be separated after drilling and the burrs removed.
       11.2.4.3 Holes in connecting angles and plates, other than splices,
also in roof members and light framing, may be punched full size through
material not over 12 mm thick, except where required for close tolerance
bolts or barrel bolts.
       11.2.4.4 Matching holes for rivets and black bolts shall register
with each other so that a gauge of 1.5 mm or 2.0 mm ( as the case may be
depending on whether the diameter of the rivet or bolt is less than or
more than 25 mm ) less in diameter than the diameter of the hole will pass
freely through the assembled members in the direction at right angle to
such members.    Finished holes shall be not more than 1.5 mm or 2.0 mm
 (as the case may be ) in diameter larger than the diameter of the rivet
or black bolt passing through them, unless otherwise specified by the
engineer.
      11.2.4.5 Holes for turned and fitted bolts shall be drilled to a
diameter equal to the nominal diameter of the shank or barrel subject to
H8 tolerance specified in IS : 919-1963.   Preferably parts to be connected
with dose tolerance or barrel bolts shall be firmly held together by packing
bolts or clamps and the holes drilled through all the thicknesses at one
operation and subsequently reamed to size. All holes not drilled through
all thicknesses at one operation shall be drilled to a smaller size and
reamed out after assembly.    Where this is not practicable, the parts shall
be drilled and reamed separately through hard bushed steel jigs.
      11.2.4.6   Hole’s for rivets or bolts shall not be formed by gas cutting
process.
11.3 Assembly     - The component parts shall be assembled and aligned in
such a manner that they are neither twisted nor otherwise damaged, and
shall be so prepared that the specified cambers, if any, provided.
11.4 Riveting
   11.4.1 Rivets shall be heated uniformly throughout their length,
without burning or excessive scaling, and shall be of sufficient length to
provide a head of standard dimensions.        They shall, when driven,
                                      109
completely fill the holes and, if countersunk, the countersinking shall be
fully filled by the rivet, any protrusion of the countersunk head being
dressed off flush, if required.
   11.4.2 Riveted members shall have all parts firmly drawn and held
together before and during riveting, and special care shall be taken in
this respect for all single-riveted    connections.  For multiple riveted
                                                                               SUPPLIED BY BOOK SUPPLY BUREAU
                                                                               LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
connections, a service bolt shall be provided in every third or fourth hole.
   11.4.3 ‘Wherever practicable, machine riveting shall be carried out by
using machines of the steady pressure type.
   11.4.4 All loose, burned or otherwise defective rivets shall be cut out
and replaced before the structure is loaded, and special care shall be taken
to inspect all single riveted connections.
   11.4.5   Special care shall be taken in heating and driving long rivets.
11.5 Bolting
   11.541Where necessary, washers shall be tapered or otherwise suitably
shaped to give the heads and nuts of bolts a satisfactory bearing.
   11.5.2 The threaded portion of each bolt shall project through the nut
at least one thread.
   11.5.3 In all cases where the full bearing area of the bolt is to be
developed, the bolt shall be provided with a washer of sufficient thickness
under the nut to avoid any threaded portion of the bolt being within the
thickness or the parts bolted together.
11.6 Welding
   11.6.1 Welding shall be in accordance with IS : 816-1969, IS : 819-1957,
IS : 1024-1979,IS : 1261-1959, IS : 1323-1982      and IS : 9595-1980, as
appropriate.
   11.6.2 For welding of any particular type of joint, welders shall give
evidence acceptable to the purchaser of having satisfactorily    completed
appropriate tests as described in any of the Indian Standards - IS : 817-
1966, IS : 1393-1961, IS : 7307 ( Part 1 )-1974, IS : 7310 ( Part 1 )-I974
and IS : 7318 ( Part 1 )-1974, as relevant.
11.7 Machining      of Butts,   Caps a-d    Bases
   11.7.1 Column splices and butt joints of struts and compression. members
depending on contact for stress transmission shall be accurately machined
and close-butted over the whole section with a clearance not exceeding
O-2 mm locally at any place. In column caps and bases, the ends of shafts
together with the attached gussets, angles, channels, etc, after riveting
together should be accurately aachined so that the parts connected\ butt
                                     1.10
-..                        .--.-
                              -._-_-1.“_-.   .-.   -.._..   ._....   .   .   _....   ” .._..
                                                                                          ____l^.._.,_____     .   .I..^_
                                                                                                        IS : 888 19s4       l
      over the entire surfaces of contact.     Care should be taken that these
      gussets, connecting angles or channels are fixed with such accuracy that
      they are not reduced in thickness by machining by more than 2.0 mm.
         11.7.2 Where sufficient gussets and rivets or welds are provided to
      transmit the entire loading ( see Section 5 ) the column ends need not be
                                                                                                                                  SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                                  LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
      machined.
          11.7.3 Ends of all bearing stiffeners                              shall be machined         or ground                to fit
      tightly at both top and bottom.
         11.7.4 Slab Bases and Caps - Slab bases and slab caps, except when cut
      from material with true surfaces, shall be accurately machined      over the
      bearing surfaces and shall be in effective contact with the end of the stan-
      chion.   A bearing   face which is to be grouted direct to a foundation
      need not be machined if such face is true and parallel to the upper face.
         11.7.5 To facilitate grouting, holes shall be provided                                        where   necessary
      in stanchion bases for the escape of air.
      11.8 Solid   Round    Steel Columns
         11.8.1 Solid round steel columns with shouldered ends shall be provided
      with slab caps and bases machined to fit the shoulder, and shall be tightly
      shrunk on or welded in position.
         11.8.2 The tolerance     between the reduced end of the shaft and the
      hole, in the case of slabs welded in position, shall not exceed 0.25 mm.
         11.8.3 Where slabs are welded in position, the reduced end of the shaft
      shall be kept just sufficiently short to accommodate a filletweld around the
      hole without weld-metal being proud of the slab.
            11.8.3.1 Alternatively,          the caps and bases                              may be welded direct to
      the column without bearing             or shouldering.
             11.8.3.2 All bearing surfaces of slabs intended                                         for metahto-metal
      contact shall be machined perpendicular  to the shaft.
      11.9 Painting
         11.9.1 Painting shall be done in accordance                                        with   IS : 1477 ( Part 1 )-
      1971 and IS : 1477 ( Part 2 )-1971.
         11.9.2 All surfaces which                 are to be painted, oiled or otherwise treated
      shall be dry and thoroughly                  cleaned to remove all loose scale and loose
      rust.
          11.9.3 Shop contact      surfaces need not be painted unless specified.
       If so specified, they shall be brought together while the paint is still wet.
                                                                     111
ISt800-1984
   11.9.4Surfaces not in contact, but inaccessible      after shop assembly,
shall receive the full specified protective treatment before assembly.  This
does not apply to the interior of sealed hollow sections.
   11.9.5Chequered      plates shall      be painted    but the details    of painting
shall be specified by the purchaser.
                                                                                           SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                           LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
   11.9.6In the case of surfaces to be welded, the steel shall not be paint-
ed or metal coated within a suitable distance of any edges to be welded
if the paint specified or the metal coating would be harmful to welders or
impair the quality of the welds.
   11.9.7 Welds and adjacent parent          metal   shall   not be painted   prior   to
deslagging, inspection and approval.
   11.9.8   Parts to be encased      in concrete   shall not be painted   or oiled.
11.10 Marking
    11.10.1Each piece of steel work shall be distinctly               marked before
delivery, in accordance       with a marking diagram, and             shall bear such
other marks as will facilitate erection.
11.11 Shop Erection
   11.11.1The steelwork shall be temporarily shop erected complete or as
arranged with the inspector so that accuracy of fit may be checked before
despatch.     The parts shall be shop assembled with sufficient numbers of
parallel drifts to bring and keep the parts in place.
   11.11;2  In the case of parts drilled or punched,  through steel jigs with
bushes resulting in all similar parts being interchangeable,   the steelwork
may be shop’erected    in such position as arranged with the inspector.
11.12 Packing      - All projecting plates or bars and all ends of members
at joints shall be stiffened, all straight bars and plates shall be bundled,
all screwed ends and machined        surfaces shall be suitably packed and all
rivets, bolts, nuts, washers and small loose parts shall be packed separately
in cases so as to prevent damage or distortion during transit.
11.13   Inspection   and   Testing
   lL13.1     The inspector shall have free access at all reasonable  times to
those parts of the manufacturer’s       works which are concerned    with the
fabrication    of the steelwork and shall be afforded all reasonable  facilities
for satisfying himself that the fabrication is being undertaken in accordance
with the provisions of this standard.
    11.13.2 Unless specified otherwise, inspection shall be made at the place
of manufacture     prior to despatch and shall be conducted     so as not to
interfere unnecessary with the operation of the work.
                                           112
                                                               18 : 888 - 1984
   11.13.3 The     manufacturer     shall guarantee compliance      with    the
provisions of this standard, if required to do so by the purchaser.
    11.13r4 Should any structure or part of a structure     be found not to
comply with any of the provisions of this standard, it      shall be liable to
                                                                                  SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                  LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
rejection.   No structure or part of the structure, once     rejected shall be
resubmitted for test, except in cases where the purchaser   or his authorised
representative considers the defect as rectifiable.
   11;13;5 Defects which may appear during fabrication shall be made
good with the consent of and according to the procedure laid down by the
inspector.
    lL13.6 All gauges and templates necessary to satisfy the inspector shall
be supplied by the manufacturer.      The inspector, may, at his discretion,
check the test results obtained at the manufacturer’s works by independent
tests at the Government Test House or elsewhere, and should the material
so tested be found to be unsatisfactory, the costs of such tests shall be borne
by the manufacturer, and if satisfactory, the costs shall be borne by the
purchaser.
11~14 Site Erection
   11.14;1 Plant and Equijment - The suitability and capacity of all plant
and equipment used for erection shall be to the satisfaction of the
engineer.
   11.14.2 Storing and Handling - All structural steel should be so stored
and handled at the site that the members are not subjected to excessive
stresses and damage.
   11.14.3 Setting Out - The positioning and levelling of all steelwork, the
plumbing of stanchions and the placing of every part of the structure with
accuracy shall be in accordance with the approved drawings and to the
satisfaction of the engineer.
  11.14.4   Security During Erection
       11.14.4.1 For safety precautions during erection     of steel structures
reference shall be made to IS : 7205-1973.
       11.14.4.2 During erection, the steelwork shall be securely bolted or
otherwise fastened and, when necessary, temporarily braced to provide
for all load to be carried by the structure during erection including those
due to erection equipment and its operation.
      llr14.4.3  No riveting, permanent bolting or welding should be done
until proper alignment has been obtained.
                                                                                                                               ..
IS : 800 - 1984
  llil4.5    Field Connections
               Field riveting - Rivets driven at the site shall be heated
       11.14.5.1
and driven with the same care as those driven in the shop.
     11.14.5.2  Field bolting - Field bolting   shall be carried   out with    the
same care as required for shop bolting.
       lli14.5;3 Field welding - All field assembly and welding shall be
                                                                                          SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                          LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
executed in accordance with the requirements    for shop fabrication except-
ing such as manifestly apply to shop conditions only.    Where the steel has
been delivered painted, the paint shall be removed before field welding,
for a distance of at least 50 mm on either side of the joint.
lL15    Painting   After Erection
   11.15.1 Betbre painting of such steel which is delivered unpainted, is
commenced,     all surfaces to be painted  shall be dry and thoroughly
cleaned from all loose scale and rust.
   11~15.2 The specified protective     treatment    shall be completed    after
erection.   All rivet and bolt heads and the site welds after de-slagging
shall be cleaned.    Damaged   or deteriorated    paint surfaces shall first be
made good with the same type of paint as the shop coat. Where specified,
surfaces which will be in contact after site assembly shall receive a coat of
paint ( in addition to any shop priming ) and shall be brought together
while the paint is still wet.
    11.15.3 Where the steel has received a metal coating in the shop, this
coating shall be completed on site so as to be continuous over any welds
a:ld site rivets or bolts, but subject to the approval of the engineer protec-
tion may be completed by p@nting on site. Bolts which have been galvaniz-
ed or similarly treated are exempted from this requirement.
   11.15.4 Surfaces     which will be inaccessible   after site assembly      shall
receive the full specified protective treatment before assembly.
   11.15.5 Site painting-should not be done in frosty or foggy weather, or
when humidity     is such as to cause condensation    on the surfaces to be           :
painted.
11.16 Bedding  of Stanchion   Bases         and Bearings of Beams             and
Girders on Stone, Brick or Concrete         ( Plain or Reinforced )
   11.16.1 Bedding shall be carried out with portland cement, grout or
mortar, as described under 11.16.4 or fine cement concrete in accordance
with IS : 456-1978.
   11.16.2 For multi-storeyed buildings, this operation shall not be carried
out until a sufficient number of bottom lengths of stanchions have been
properly lined, levelled and plumbed and suffkient floor beams are in
position.
                                      114
   11.16.3 Whatever method is employed the operation shall not be
carried out until the steelwork has been finally levelled and plumbed,
the stanchion bases being supported meanwhile by steel wedges; and im-
~~n~ez.ly before grouting, the space under the steel shall be thoroughly
        .
                                                                           SUPPLIED BY BOOK SUPPLY BUREAU
                                                                           LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
   11.16.4 Bedding of structure shall be carried out with grout or mortar
which shall be of adequate strength and shall completely fill the space to be
grouted and shall either be placed under pressure or by ramming against
fixed supports.
  SECTION 12 STEEL-WORK TENDERS AND CONTRACTS
12.1 General   Recommendations
   12.1.1 A few recommendations      are given in Appendix G for general
information.
                                     115
 MiWO-19S4
                                APPENDIX          A
                                  ( Clause3.3.2 )
     CHART SHOWING HIGHEST MAXIMUM TEMPERATURE
                                                                                                   SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                   LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
The territorial  waters of India extend into the sea to a dietance of twc!ve nautical      miles
measured from thcs appropriate      base line.
Bred upon Survey of India map with,thc           permission of the Surveyor    General of India.
Q Government      of India Copyright     195.
Responsibility  for the correctness   of internal details rests with the publishers.
                                              116
                                                                                       IS : 800   l   1984
                                   APPENDIX            B
                                      ( Clause 3.3.2 )
      CHART        SHOWING LOWEST                      MINIMUM            TEMPERATURE
                                                                                                       SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                       LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
The territorial waters of India extend into the sea to a distance of twelve nautical miles
measured from the appropriate      base line.
Based upon Survey of India map with the permission     of the Surveyor   General of India.
6 Government     of India Copyright    1995.
Responsibility   for the correctness   of internal     details   rests with the publishers.
                                                     117
’   IS:800-1984
                             APPENDIX           C
                                ( Clause 5.2.2)
                    EFFECTIVE      LENGTH      OF COLUMNS
                                                                                     SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                     LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
    C-l. In the absence of more exact analysis, the.effective length of columns
    in framed structures may be obtained from the ratio I/&, of effective length
    1 to unsupported length L given in Fig. C-l when relative displacement
    of the ends of the column is prevented and in Fig. C-2 when relative
    lateral displacement of the ends is not prevented.    In the later case, it is
    recommended that the effective length ratio l/L may not be taken to be
    less than 1.2.
          In Fig. C-l and Fig. C-2, fi1 and & are equal to       z xll --
                                                             L x0 + 2       Kb
    where the summation is to be done for the members framing into a joint
    at top and bottom respectively; & and xb being the flexural stiffnesses for
    the column and beam, respectively.
                                         118
                  LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
f$ : 808 - 1984
                  SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                     LENGTHRATIOSFORA COLUMN
                                                                                             IN A FRAMEWITHNo SWAY
                                                                                                                               119
                                                                                            EFFECTIVE
                                                                                            FIG. C-l
       HINGED I. 0
                                                                                     SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                     LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
  FIXED        0                                                        HINGED
                   0     0.1   0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
                                            P2-
                   z
                   li:
               C-2
           FIG.'          EFFECTIVE LENQTH RATIOS FOR A COLUMN IN A
                       FRAME WITHOUT RESTRAINT AGAINST SWAY
                               APPENDIX                D
                                  ( Clause 5.2.5   )
         METHOD           FOR DETERMINING  EFFECTIVE           LENGTH
                            FOR STEPPED COLUMNS
D-l.    SINGLE         STEPPED    COLUMNS
D-l.1   Effective lengths in the plane of stepping ( bending about axis x-x )
for bottom and top pa.rts for single stepped columns shall be taken as given
in Table D-l.
       NOTE - The provisions of D-l.1 are applicable to intermediate columns as
  well with steppings on either side, provided appropriate values of ZI and Is are
  taken.
                                        120
      TABLE   D-1    EFFECTIVE        LENGTH     OF SINGLED     STEPPED          COLUMNS
                                         ( Clause D-l.1 1
SL       DEOREF: OF END               SKETCH       EFFECTIVELENGTH                    COLUMN
rl0.        RESTRAINT                                COEFFICIENTS                 PARAMETERS FOI
                                                                                     ALL CASES
(1)               (2)                     (3)                 (4)                        (5)
                           -.
 a)    Effectively    held in
                                                                                                       SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                       LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
        position and restrai-
        ned against       rota-
        tion at both ends
                                                        k,, and XII are to
                                                        be taken as per
                                   -I+-
b)     Effectively   held    in
        ends and restrained
        against rotation. at
        bottom end only
                                                    where                          8s    I,     LX
                                                                                  -=
                                                         k1, and III are to        it    TX-T
                                                                                            P    1
                                                         Fa;;ke;    3” per
       %fectively     held in _                     A, to be taken as per          Effective length
         position and restrai-            M      Table D-4                        of bottom part o
         ned against      rota-                                                   column in plant
         tion at bottom end.                           k, =   2;    c   3
                                                                                  of stepping
         and top end held
                                                                                  - k,L,
         ag8inst      rotation
         but not held         in
         poaition
                                                                                   Effective lengtl
                                                                                  of top part      0
                                          I_                                      column    in plant
                                                                                  of stepping=k&
d)      Effectively   held in
         position and restrai-
                                                     II to
                                                  per Table
                                                              be taken
                                                              D-5
                                                                            as
         ned against      rota-
         tion at bottom end,
         and top end neither
         held against    rata-
         tion nor held       in
         position
                                                                                                                                                     UPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                                                      CENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
          TABLE D-2 COEFFICIENTS OF BFFEZTIVE LENGTHS ii,, AND i& FOR COLUMNS WITH BOTH                                                              tr
                                                                                                                                                     ”
                BNDS BFFECTIVELY HELD IN POSITION AND RESTRAINED AGAINST ROTATION
                                          ( Tab& D-l )
         x
        A-                                   ~ESrICDENTB          11,   AND    xl,    POR    h/r,      EQUAL      TO
         11     * 0.1   0.2    0’3     0.4      0’5      @S-r&                         0.9          1’0     1.2        1.4    I.5    1’8    -2:;
                                                        _th*              (h=O)
        0’05     0’74   094    1.38    1’60     1’87     2’0:  2.23           2’39     2’52         2’67    3’03       3.44   3.85   4’34     4’77
        0’1      0.67   0.76   l-00    1.20     l-42     1’61 1’78            1’92     2’04         2’20    2’40       2’60   2’86   3’18     3’41
        0’2      0’64   0’70   0’79    0’93     1’07      1.23 1’41            1’50    1’60         1’72    1’92       2‘11   2’28   2’45     2’64
        0’3      0’62   0.68   0’74    0’85     0’95      1.06 1’18            1’28    1’39         1’48    1’67       1.82   1’96   2’12     2’20
        0’4      0’60   0’66   0.71    0’78      0’87      0’99    1’07       1.16      1’26        1’34    1.50       1.65   1.79   1’94     2’08
        0.5      0’59   065    0’70    0.77      0’82      0’93    0’99       1’08      1’17        1’23    199        1’53   1.66   1’79     1’92
        1’0      0’55   0.60   0’65    0’70      0’75      W80     0’85       0’90      0’95        1.00    1.10       1*20   1’30   1.40     1’50
    E
    N                                                   Cq&8nr~~((P*~O)
        0’05     0.65   0’67   0.71    b-85     1’01     1’17      1’31       1’41      1’50        1’57    1’67       1’74   1’78   1’82     1’86
        O-1      0.64   0’65   0’65    0’65     0’78     0’92      1’05       1’15      1’25        1’33    1.45       1’55   1’62   1’68     1’71
        0’2      0.62   0’64   0.65    0.65     0.66     0.73     0.83        0.92      1’01         1’09    1’23      1.33   1’41   1’48     1’54
        09       OWI    0’63   OS4     0’65     0’66     0’67     ti73        0’81     0’89         0’94    1’09       1’20   1’28   195      1’41
        0’4      0’58   0’63   0’63    0’64     0’64     0%       OS8         0’75     0’82         0’88    1’01       1’10   1’19   1’26     1’32
        0’5      0’57   0’61   0.63    0’64     0’64     0.65     0’68        0’72     0’77         0’83    0’94       1.04   1’12   1’19     1’25
        1’0      0’55   0’58   0.60     0’61     0’62    0’63      0.65       0’67     0’70         0’73    0’80       0.88   0.93   1’01     1’05
               NOTE -   Intermediate     value may be obtained by interpolation.
.
                                                                                                                              SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                              LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                 TABLE       D-3 COEFFICIENTS   OF EFFECTIVE LENGTHSX,,    AND El, FOR COLUMXS   WITH
                            BOTH ENDS EFFECTIVELY    HELD IN POSITION   AND RESTRAINED   AGAINST
                                              ROTATION   AT BOTTOM    END ONLY
                                                                   ( Tuble D-l )
                                            COEFBICIENTSklr AND LIZBOR Lp/LI EQUAL TO
          I,/Zl r------------                     __~~_~~*~_-----_____-
                  0’1      O-2   0’3    0’4   0’5    0’6   0’7     0.8  0’9 1’0 1’2 1’4                  1’6    1’8
                                                     coq$%imt I,* ( PI = 0 )
          0’05   0’97    1’66 2’10      2’43   2’72 2’92    3’08 3’24 3’48        3.73    4’22    4’85   5’36   6’00   6’58
          0’1    0’83    1’21 1’57      1’95   2’14 2’33    2%    2’60 2’76       2’91    3.28    3.61   4’03   4’43   4’85
          0’3    0’78    0’90 1’09      1’27   1’44 1’60    1’74 1’86 1’98        2’11    2’35    2’51   2’76   2’99   3’25
     ‘s
     w    0.5    0’78    O-86 0’99      1’10   1’22 1’35    l-47  1’57 J’67       1’76    1’96    2’15   2’34   2’50   2’76
           1’0   0’78    O-85 0’92      0’99    1’06 1’13    1’20 1’27 1’34        1’41    1’54   1’68   1’82   1’97   2’10
                                                     Coe&ientI,, ( Pr = 0 )
          0’05   0’67    0’67    0’82   1’16 1’35    1’48   1’58   l-65    1’69    1’74   1’81    1’84   1’86   1’88   1’90
          O-1    0’67    0.67    0’73   0’93 1’11    1’25   1’36   1’45    1’52    1.57   1’66    1’72   1’77   1’80   1’82
          O-3    0’67    0.67    0’67   0’71 0.80    O-90   0’99    1’08   1’15    1’22   1’33    1’41   1’48   1’54   1’59
          O-5    0’67    0’67    0.67   0’69 0’73    0’81   0’87   0’94    1.01    1’07   1’17    1’26   1’33   1’39   1’44
          1’0    0’67    0’67    0’67   O-68 0’71    0’74   0’78   0’82    0’87    0’91   0.99    1’07   1’13   1’19   1’24
                 Nom    -    Intermediate   values may be obtained by interpolation.
::
                                                                                                                             SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                             LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
          TABLE D-4 COEFFICIENT OF EFFECTIVE LENGTH k; FOR COLUMNS EFFECTIVELY HELD IN
              POSITION AND RESTRAINED AGAINST ROTATION AT BOTTOM END AND TOP END
                         HELD AGAINST ROTATION BUT NOT HELD IN POSITION
                                                                 ( TableD-l )
                                             COEFFICIENT k, BOR i,/il EQUAL TO
     Cl      r-‘-        ----~~~~~~~_~~~_*~~~~__-~~~~_~
               0     0.2     0’4   0.6   0’8   1’0  1’2   1’4    1’6   1.8  2’0                  2’5    5’0     10    20
    0        2’0    1’86   1’76     1’67     1’60    1’55   1’50    I.46    1.43   1.40   1’37   1’32   1’18   l.iO   1’05
    0’5      2’0    1’90   1’80     1’74      1’69   1’65   1’61     1’58   1’55   1’53    -      -      -      -      -
    1’0      2’0    2’00   2’00     2’00      2’00   2’00    -       -       -      -      -      -      -      -      -
c
    I.5      2-O 2.25      2.38     2.48       -      -      -       -       -      -      -      _      -      -      _
%
    2.0      2’0    2’66   2’91      -         -      -;     -       -       _      -      -      -      -      _      -
    2.5      2’5    3’17   3.50      -         -      -      -       _       _      _      _      -      -      -      -
    3.0      3’0    3.70   4.12      -         _      -      -       _       _      _      _      -      _      -      _
           NOTE -    Intermediate        values may be obtained by interpolation.
                                                                                                                                           SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                                           LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
               TABLE D-5 COEFFICIENT OF EFFECTIVE LENGTH G FOR columns WITH TOP END FREE
                      AND BOTTOM END EFFECTIVELY HELD IN POSITION AND RESTRAINED
                                            AGAINST ROTATION
                                                 COEFBICIENT k1 BOR ir/il EQUAL TO                                         ?2
         c,     ~-_-____--_---_-_T__h--______                                                      ---A--
                                                                                                                     I;
                 0      0.2     0’4   0’6     0’8  1.0   1.2   1’4   1.6    1.8 2’0          2’5   5’0    10   20
         0      2’0     2’0    2’0    2’0’1 2’0     2’0    2’0    2’0    2’0    2’0   2’0    2’0   2’0   2’0   2’0
                                                                                                                     ‘2               L2
         0’5    2’0     2’14   2’24   2’36   2’47   2.57   2’67   2.76   2’85   294   3’02    -    -      -    -            0
         1’0    2’0     2’73   3’13   3’44   3’74   4.00    -      -      -      -     -      -    -      -    -
    w
    WI   1’5    3.0     3,77   4’35   4’86    -     -       -      -      -     -      -     -     -     -     -
         2’0    4’0     4.90   5’67    _      _      -      -      -      _     -      _      _    -      -    -
                                                                                                                     11               LI
         2.5    5.0     6.08   7.00    _      -      -      -      _      _      _     -      -    -      -    -
         3’0    6’0     7.25    _      -      _     -       -      _      -     -     -      -     _     _     _
               NOTE -    Intermediate values may be obtained by interpolation.                                            1 P, t P2
,
rsrm-1984
D-2. EFFECTIVE                   LENGTH            FOR DOUBLE           STEPPED                COLUMNS
D-2.1 Effective lengths in the plane of steppings ( bending about axis x-x )
for bottom, middle and top parts for a double stepped column shall be
taken as follows:
                                                                                                            SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                            LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                            G
                !ilif
                            13                                                4
               L3            p2                          8,        L3         P
                                                     I av
                                          L2fL-j
                                 I2
               L2                                        P
                                 P(                                                                   ,
                                                                                  1 av                 av
                                                               LI+Lz                     Ll+
         Y     L,                 11         L,          11
         I
  x$%x                           4                       .                    A
         Y
                           (a)                     (b)                  (cl                      (4
     Coefficient kl for effective length of bottom part of double stepped
column shall be taken from the formula:
     where
             xl,&, &             are taken from Table D-6,
                      t1=--,
                                     Pl
                              pa
                          ta = pa
                               -
                                 pli
                                 La
                          % =--9
                                 Ll
                    I’,      = Average value of moment of inertia for the lower
                               and middle parts
                                I,&          + Is&
                              =4+              Ls
                                                         126
                                                                                    IS:8w-19fM
               I”, =     Average   value of moment of inertia for middle and
                          top parts
                             IaLa + WI
                     -       Ls    + r,
       Value   of coefficient Ts for middle part of column is given by for-
mula
                                                                                                 SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                 LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                                                          kl
                                            ks   E-
                                                          G
and coefficient kB for the top part of the column is given by
       where
                    C,S       G              11       (   p,     +    ps   1
                              Ll   J   1,   ( Pl          +     ps    +    m-
                              LB                              IlPB
                    c,   =    -
                              Ll   d   13 ( Pl            +      pa   +    pa   1
      NOTE-The       provisions of D-2.1 are applicable to intermediate   columns as
  well with steppings on either side, provided appropriate values of Z,, Zs and 1s are
  taken.
                                                      127
                                   LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                                   SUPPLIED BY BOOK SUPPLY BUREAU
As in the Original Standard, this Page is Intentionally Left Blank
                                      TABLE   D-6   VALUES     OF i;,, k; AND k;
                                                    ( Cluusc D-2.1 )
      DEGREE 01 END          SKNTCH                                                          h               COLUhtN
        R~CSTRAINT                                                                                          PAHAMETEHS
                                                                                                           FOR ALL CASES
a:   Effectively held in                       & = lu                  7;s= I,,            lir = ilr.
                                                                                     where k,s is taker
      position and re-                    where krl is taken   where 1,~ is taker:
      rtrained against                     from Table D-2       from Table D-2        from Table D-2
      rotation at both
      ends.
                                                                                                                           SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                           LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
bi   Effectively
      in position
                     held
                        at   ,                 %I= k‘,
                                          where kI1 is taken
                                                                       ta- tn
                                                               where in is taken     where
                                                                                           k, = ha
                                                                                            1ss is taken
                             ,
                             E
                                                                from Table D-3        form Table D-3
      both           ends                 from Table D-3
      and     restrained
      against rotation
      at bottom       end
      only.
C) Wectively held in                           k, = 2,                 1, - L            x, -    ;k,
                                                                                      where x1 is taken
      position and re-                    Hhrre Ik is taken    #here kI is taken
                                                                                     ‘ram Table D-4 with
                                                                                                    .-
      strained   against                  from !‘able D-4      from Table D-4
      rotation                             with C, = 0          with C, = 0
      bottom end, ai;
      top     end held
      against rotation
      but not held in
      position.
d)   Xectively held in                         h, = 2                  ;kr = 2            i, =    ;tr
     position and re-                                                                uhere  k1 is taken
     strained  against                                                               rom Table D-S with
     rotation                                                                        ?    I
                                                                                       - ~.A_.  IT
     bottom end? anad                                                                “L-L1+L, J x
     top end neither
     held      agaiyt
     rotation      nor
      against   trans-
     lation.
                                   LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                                   SUPPLIED BY BOOK SUPPLY BUREAU
As in the Original Standard, this Page is Intentionally Left Blank
                           APPENDIX             E
                             ( Clause 6.2.4.1 )
       LIST OF REFERENCES   ON THE ELASTIC FLEXURAL
            TORSIONAL  BUCKLING  OF STEEL BEAMS
                                                                                              SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                              LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
Textbooks
TIMOSHENKO       ( S P ) and GERE ( J M ).                Theory of elastic stability.
Ed 2, 1961. McGraw-Hill, New York.
BLEICH ( F ), Buckling       Strength    of Metal      Structures,   1952.     McGraw-
Hill, New York.
JOHNSTON      ( B G ), Ed. Guide to design criteria for metal compres-
sion members. Column Research Council. 1966, Ed 2. John Wiley, New
York.
GALAMBOS       ( T V ).     Structural members and frames.           1968.      Prentice-
Hall, New Jersey
Handbook of Structural Stabi&.  Column Research                 Committee of Japan.
197 1. @rona Publishing Co, Tokyo.
Allen ( H G ) and B&on           ( P S ). Background     to buckling.
Stability of structure under static and dynamic loads. American Society of
Civil Engineers, 1977 Ed.
RGfeerencesPrior to I961
LEE ( G C ), A survey of literature on the lateral instability                 of beams.
Welding Research Council Bulletin Series No. 63, Aug 1960.
Values of Elastic Critical Loads and Effectioe Length Factors
TRAHAIR’(    N S ) . The Bending stress rules of the draft AS CA 1. J Inst.
Engrs Aust. 38; No. 6, June 1966.
TRAHAIR      ( N S ). Elastic Stability of I-beam element in rigid-jointed
frames. J Inst. Engrs Aust. 38; No. 7-8 July-Aug 1966; 171.
TRAHAIR      ( N S ). Elastic stability of propped cantilevers. Civ Eng
Tram, Institution of Engineers, Australia, V CE 10. No. 1; April 1968.
Safe load tables for laterally     unsupported angles.       Australian      Institute   of
Steel Construction.
                                         131
                                                                                                                                SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                                                LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                                             APPENDIX                      F
                                                  ( Clause 9.2.3.2 )
                        PLASTIC    PROPERTIES OF INDIAN STANDARD MEDIUM
                                  WElGHT BEAMS [ IS : 808 ( Part l )-1973 ]
DEMONA-      WEICJHT      SEC- L&PEE      WIDTE T~cE-  THICIL- Rano~              SECTION       PLASTIC SE-E b          D
  TION                   TIONkt   OB        OR   NESS   NY85    GYRA-             MODU-         SE&ON FACTOB T-         t
                          AHEA SEC-       FLANGE OP       OB                                     MODU-
                                  TION       (4  FLAN-
                                                                 TION               LUS
                                                                                    L             LUS
                                                                                                         _$-            -
                                  (4                                                              ‘ZP
                                                   El
 (1)             (2)       (3)     (4)      (5)      (6).    (7)    (8)    (9)          (10)      (11)   (121   (13)    (14)
                kg/m      cm*      mm      mm       mm       mm     cm     cm           cm3      cm5
ISMB      100   11.5      14’7     100     70      7’5      4’5    4’14    1’55         50’4      58’6   1’16   9-33    22’2
ISMB      125   13.4      17’0     125     70      8’0      5’0    5’16    1’51         71’2      81’8   1’15   8’75    25’0
ISMB      150   15        19-l     150     75      8’0      5’0    6’13    1’57         95’7     110     1’15   9’38    30’0
ISMB      175   19’5      24’9     175     85       9’0     5.8     7.13   1’76         144’3    166     1’15   9’44    30’17
ISMB      200   25’4      32’3     200     100     10’8     5.7     8.32   2’15      224         254     1’13   9’26    35’1
ISMB      225   31.2      39’7     225     110     11’8     6’5     9’31   2’34         306      348     1’14   9’32    34’6
ISMB   250      37.3      47%      250     125     12’5     6’9    10’40   2’65      410         466     1’14   10’00   36’2
ISMB      300   46-l      58.7     300     140     13-l     7.7    12’40   2’86      599         683     1’14   10’7    38’9
ISMB      350   52’4      66.7     350     140     14’2     a.1    14-30   2’84      779         890     1’14   9’86    43.2
ISMB      400   61’6      78’5     400     140     16’0     8’9    16’2    2’82     1020        1 176    1’15    8’75   44.9
ISMB      450   72’4      92’3     450     150     17.4     9’4    18’2    3’01     1350        1533     1’14    8’62   47’9
ISMB      500    86’9     111       500     180    17.2     10’2   20’2    3’52     1810        2075     1’15   10’47   49.0
ISMB      550   104       132      550     190     19’3     11’2   22’2    3.73     2360        2712     1’15    9.84   49’1
ISMB      600   123        156      600    210     20’8     12’0   24’2    4’12     3060        3511     1’15   10’10   50.0
                                                               IS:lam-1984
                          APPENDIX            G
                             ( czause12.1.1 )
        GENERAL      RECOMMENDATIONS   FOR STEELWORK
                      TENDERS AND CONTRACTS
                                                                             SUPPLIED BY BOOK SUPPLY BUREAU
                                                                             LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
G-O. GENERAL
G-041 The recommendations given in this Appendix are in line with those
generally adopted for steelwork construction and are meant for general
information.
G-O.2 These recommendations do not form part of the requirements of the
standard and compliance with these is not necessary for the purpose of
complying with this Code.
G-O.3 The recommendations       are unsuitable for inclusion as a block
requirement in a contract, but in drawing up a contract the points men-
tioned should be given consideration.
G-l.    EXCHANGE       OF INFORMATION
G-161 Before the steelwork design is commenced, the building designer
should be satisfied that the planning of the building, its dimensions and
other principal factors meet the requirements of the building owner and
comply with regulations of all authorities concerned.    Collaboration of
building designer and steelwork designer shouId begin at the outset of
the project by joint consideration of the planning and of such questions
as the stanchion spacing, materials to be used for the construction, and
depth of basement.
G-2. INFORMATION           REQUIRED       BY THE    STEELWORK
     DESIGNER
G-2.1    General
        a) Site plans showing in plan and elevation of the proposed Iocation
           and main dimensions of the building or structure;
        b) Ground levels, existing and proposed;
        c) Particulars of buildings or other constructions which may have to
           remain on the actual site of the new building or structure during
           the erection of the steelwork;
        d) Particulars of adjacent buildings affecting, or affected-by, the new
           work;
        e) Stipulation regarding the erection sequence or time schedule;
        f > Conditions affecting the position or continuity of members;
                                       133
ISrfmJ-19g4
        g) Limiti of length and weight of steel members in transit and
           erection;
        h) Drawings of the substructure, proposed or existing, showing:
           il levels of stanchion foundations, if already determined;
                                                                                        SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                        LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
             ii) any details affecting the stanchion bases or anchor bolts;
             iii) permissible bearing pressure on the foundation; and
             iv) provisions for grouting ( scd 11.16 ).
                 In the case of._ new work, the substructure should be designed
             in accordance with the relevant codes dealing with foundations
             and substructure;
        j)    The maximum wind velocity appropriate to the site ( ste IS : 875-
              1964 ); and
        k) Environmental   factors, such as proximity to sea coast, and corro-
           sive atmosphere. Reference to bye-laws and regulations affecting
           the steelwork design and construction.
012.2        Further Information      Rtlatiag   to Buildings
        4     Plans of the floors and roof with principal dimensions, elevations
              and cross sections showing heights between floor levels.
        b)     The occupancy of the floors and the positions of any special loads
               should be given.
        4     The building drawings, which should be fully dimensioned, should
              preferably be to the scale of 1 to 100 and should show all stairs,
              fire-escapes, lifts, etc, suspended ceilings, flues and ducts for
              heating and ventilating. Doors and windows should be shown, as
              the openings may be taken into account in the computation of
              dead load.
                  Requirements   should be given in respect of any maximum
               depth of beams or minimum head room.
                   Large-scale details should be given of any special features
               affecting the steelwork.
         4     The inclusive weight per ms of walls, floors, roofs, suspended
               ceilings, stairs and partitions, or particulars, of their construction
               and finish for the computation of dead load.
                    The plans should indicate the floors which are to be designed
               to carry partitions.  Where the layout of partitions is not known,
               or a given layout is liable to alteration, these facts should be
               specially noted so that allowance may be made for partitions in
               any position ( see IS : 875-1964 ).
                                            134
                                                                         IS 1809-1984
       e) The superimposed loads on ,the ,floors appropriate to the occu-
          pancy, as given in IS : 875-1964 or as otherwise required.
       f)      Details of special loads from cranes, runways, tips, lifts, bunkers,
               tanks, plant and equipment.
       g) The grade of fire resistance appropriate to the occupancy as may
          be required.
                                                                                      SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                      LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
G-3.     INFORMATION              REQUIRED      BY TENDERER            ( IF NOT ALSO
         THE DESIGNER             )
G-3.1 General
         a) All information       listed under G-2.1;
         b) Climatic conditions at site-seasonal variations             of temperature,
            humidity, wind velocity and direction;
         c) Nature of soil. Results of the investigation         of sub-soil at site of
            building or structure;
         d) Accessibility of site and details of power supply;
         e) Whether the steelwork contractor will be required to survey the
            site and set out or check the building or structure lines, founda-
            tions and levels;
         f)     Setting-out   plan of foundations, stanchions and levels of bases;
         g) Cross sections and elevations of the steel structure, as necessary,
            with large-scale details of special features;
         h) Whether the connections are to be bolted, riveted or welded.
            Particular attention should be drawn to connections of a special
            nature, such as turned bolts, high strength friction grip bolts, long
            rivets and overhead welds;
         j) Quality of steel ( see 3 ), and provisions for identification;
         k) Requirements in respect of protective paintings at works and on
            site, galvanizing or cement wash;
         m) Approximate dates for commencement and completion of erec-
            tion;
         n) Details of any tests which have to be made during the course of
            erection or upon completion; and
         p) Schedule of quantities.     Where the tenderer is required to take
            off quantities, a list should be given of the principal items to be
            included in the schedule.
 G-3.2        Additional      Information   Relating    to Buildings
         a) Schedule of stanchions giving sizes, lengths and typical details of
            brackets, joints, etc;
                                              535
L.     ._            ..._ _ ..__.“.,_._.ll_l_l_l-l._~-_   ._. _..__. ...“..   .._- -_.._
             b) Plan of grillages showing sizes, lengths and levels of grillage
                beams and particulars of any stiffeners required;
             c) Plans of floor beams showing sizes, lengths and levels eccentrici-
                ties and end moments.     The beam reactions and details of the
                type of connection required should be shown on the plans;
             d) Plan of roof steeldork.    For a flat roof, the plan should give par-
                ticulars similar to those of a floor plan. Where the roof is
                                                                                                 SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                 LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                 pitched, details should be given of trusses, portals, purlins, brac-
                ing, etc;
             e) The steelwork drawings should preferably be to a scale of’ 1 to
                 100 and should give identification marks against all members;
                and
             f ) Particulars of holes required for services, pipes, machinery fixings,
                 etc. Such holes should preferably be drilled at works.
     G-3.3    Information       Relating to Execution of Building Work
       G-3.3.1 Supply of materials.
       G-3.3.2     Weight of steelwork for payment.
       G4.3.3      Wastage of steel.
       G-3.3.4     Insurance,    freight and traniport from shop to site.
       G-3.3.5     Site facilities for erection.
        G-3.3.6    Tools and plants.
       G-3.3.7     Mode and terms of payment.
       G-3.3.8     Schedules.
       G3.3.9   Forced Majewe - clauses and provisions for liquidation                     and
     damages for delay in completion.
        G-3.3.10    Escalation clauses.
     G-4,    DETAILING
     G-4.1 In addition to the number of copies of the approved drawings or
     details required under the contract, dimensioned shop drawings or details
     should be submitted in duplicate to the engineer who should retain one
     copy and return the other to the steel supplier or fabricators with his
     comments, if any.
     c-5.    TIME SCHEDULE
     G-5.1 As the dates on which subsequent trades can commence, depend on
     the progress of erection of the steel framing, the time schedule for the
     latter should be carefully drawn up and agreed to by the parties concerned
      at a joint meeting.
                                                   136
                                                               IS:SwJ-1984
G-6.    PROCEDURE      ON SITE
G-6.1  The steelwork contractor should be responsible for the positioning
and levelling of all steelwork. Any checking or approval of the setting out
by.the general contractor or the engineer should not relieve the steelwork
                                                                              SUPPLIED BY BOOK SUPPLY BUREAU
                                                                              LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
contractor of his responsibilities in this respect.
G-7.    INSPECZTION
G-7.0   References may be made to IS : 7215-1974, c Indian Standard
tolerances for erection of steel structures ( under preparation ) ‘, and the
(Handbook      for fabrication, erection and inspection of steer structures
( under preparation )’ for general guidance.
‘G-7.1 Access      to Contractor’s     Works - The contractor      should offer
 facilities for the inspection of the work at all stages.
G-7.2  Inspection of Fabrication +Unless      otherwise agreed, the inspec-
tion should be carried out at the place d fabrication.      The contractor
should be responsible for the accuracy of the work and for any error which
may be subsequently discovered.
G-7.3 Inspection    on Site - To facilitate     inspection, the contractor
should during all working hours, have a foreman or properly accredited
charge hand available on the site, together withia complete set of contract
drawings and any further drawings and instructions which may have been
issued from time to time.
G-8, MAINTENANCE
G-8.1   General - Where steelwork is to. be encased in solid concrete,
brickwork or masonry, the question of maintenance should not arise, but
where steelwork is to be housed in hollow fire protection or is to be unpro-
tected, particularly where the steeIwork is exposed to a corroding agent,
the question of painting or protective treatment of the steelwork should be
given careful consideration at the con_stn;lction stage, having regard to the
special circumstances of the case.
G-8.2 Connections - Where connections are exposed to a corroding
agent, they should be periodically inspected, and any corroded parw
should be thoroughly cleaned and painted,
    G-8.2.1 Where bolted connections      are not solidly encased and are sub
ject to vibratory effects of machinery    or plant, they should be periodicalv
 inspected and all bolts tightened.
                                         137
                                                                                        ^
                                                                             1.
L
    INDIAN         STANDARDS
    ON
    STRUCTURAL        ENGINEERING
    IS:
                                                                                                      SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                      LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
     800-1984      Code of practice for general construction in steel ( second rsoizioa )
     Sol-1975      Code of practice for use of cold formed light gauge steel structural members
                   in general building construction (Jirsr rcuision ).
    ,802 Code of practice for use of structural steel in overhead transmission line towers:
       ( Part 1 )-I977 Loads and rJermissible stresses ( second revision 1
        t Part 2 j-1978      Fabrication, galvanizing, inspection and packing
        ( Part 3 l-1978      Testing
     803-1976     &de of practice for design, fabrication and erection of vertical mild steel
                   cylindrical welded oil storage tanks (first rcnision )
     805-1968 Code of practice for use of steel in gravity water tanks
     806-1968      Code of practice       for use of steel tubes in general building construction
                   C retiscd 1
     807-1968      &ode ofpractice      for design, manufacture, erection and testing ( structural
                   portion ) of cranes and hoists (first reoision y
    1915-1961      Code of practice for steel bridges               ,
    3177-1977      Codeof practice for design of overhead travelling cranes and gantry
                                                                                     _     . cranes
                   other than steel-works c&i& (Jirsf revision )         -
    4000-1967       Code of practice for assembly of structural joints using high tensile friction
                      . e
                   grip tasreners
    4014      Code of practice for steel tubular scaffoldings:
         ( Part 1 )-I967     Definitions and materials
         ( Part 2 )-1967     Safety regulations for scaffolding
    4137-1967      Code of practice for heavy dut electric overhead travelling cranes inclu-
                   ding special service machines Por use in steel works
    4573-1982      Code of practice for design of mobile crane’i ( all types ) (first r&in    )
    6533-1971      Code of practice for design and construction of steel chimneys
    7205-1974      Safety code for erection of structural steelwork
    8147-1976      Code of practice for use of aluminium alloys in structurea
    8640-1977      Recommendations for dimensional paiameters for industrial buildings
    9178
    -_       Criteria for design of steel bins for storaee of bulk materials:
         ( Part l )-1979     Gen&al requirements and assesiment of loads
         ( Part 2 )-1979     Design criteria
         ( Part 3 )-1981     Bins designed for mass flow and funnel flow
    9964 Recommendations for maintenance and operation of petroleum storage tanh:
         (\ Part 1 1-1981 Prenaration
                                  .         of tanks for safe entry and work
         ( Part 2 )-1981      Inspection
    %Zleisl
     8041967     Rectangular pressed steel tanks (first revision )
    7215-1974    Tolerances for fabrication of steel structures
    8081-1976    Slotted sections
    SP : 6 ISI Kandbooks for Structural Engineers
       SP : 6 (I)-1964    Structural steel sections
       SP : 6 (2)-1962    Steel beams and plate girders
       SP : 6.(3)-1962    Steel column and struts
       SP : 6 (4)-1969    Use of high strength friction grip bolts
       SP : 6 (5)-1980    Structural use of light gauge steel
        SP : 6 (6)-1972   Application of plastic theory in design of steel structures
        SP : 6 (7).1972   Simple welded girders
                             BUREAU OF INDIAN STANDARDS
Headquartera.
Manak Bhavan, 9 Bahadur Shah Zafar Marg, NEW DELHI 110002
Telephones: 323 0131,323 3375,323 9402       Fax :+ 91 011 3234062,3239399,           3239382
E -mail : bis@vsnl.com. Internet : http://wwwdel.vsnl.net.in/bis.org
Cenffal Laboratory    :                                                             Telephone
Plot No. 20/9, Site IV, Sahibabad industrial Area, Sahibabad 201010                 77 00 32
                                                                                              SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                              Y
                                                                                              LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONL
Regional Offices:
Central    : Manak Bhavan, 9 Bahadur Shah Zafar Marg, NEW DELHI 110002              3237617
*Eastern   : l/14 CIT Scheme VII, V.I.P. Road, Kankurgachi, CALCUTTA 700054         337 86 62
Northern : SC0 335336,     Sector 34-A, CHANDIGARH        160022                    60 36 43
Southern    : C.I.T. Campus, IV Cross Road, CHENNAI 600113                          235 23 15
tWestern : Manakalaya, E.9, MIDC, Behind Marol Telephone Exchange,                  832 92 95
   Andheri (East), MUMBAI 400093
Branch Offices:
‘Pushpak’, Nurmohamed Shaikh Marg, Khanpur, AHMEDABAD                380001         550 !3 48
SPeenya Industrial Area, 1 st Stage, Bangalore-Tumkur Road,                         839 49 55
  BANGALORE 560058
Commercial-cum-Office Complex, Opp. Dushera Maidan, E=5 Arera Colony,               72 34 52
  Bittan Market, BHOPAL 462016
62/63, Ganga Nagar, Unit VI, BHUBANESWAR         751001                             40 36 27
Kalai Kathir Building, 670 Avinashi Road, COIMBATORE        641037                  21 01 41
Plot No. 43, Sector 16 A, Mathura Road, FARIDABAD         121001                    28 88 01
Savitri Complex, 116 G.T. Road, GHAZIABAD       201001                              71 19 98
53/5 Ward No.29, R.G. Barua Road, 5th By-lane, GUWAHATI            781003           541137
5-8-56C, L.N. Gupta Marg, Nampally Station Road, HYDERABAD             500001       3201084
E-52, Chiiranjan Marg, C- Scheme, JAIPUR 302001                                     37 38 79
1171418 B, Sarvodaya Nagar, KANPUR 208005                                           21 68 76
Seth Bhawan, 2nd Floor, Behind Leela           Cinema,     Naval   Kishore    Road, 21 89 23
   LUCKNOW 226001
NIT Building, Second floor, Gokulpat Market, NAGPUR 440010                          52 51 71
Patliputra Industrial Estate, PATNA 800013                                          26 28 08
institution of Engineers (India) Building, 1332 Shiiaji Nagar, PUNE 411005          32 36 35
Sahajanand House’3rd Floor, Bhaktinagar Circle, 80 Feet Road,                       36 85 86
   FtAJKOT 360802
T.C. No. 14/l 421, University P. 0. Pafayam, THIRWA NANTHAPURAM          695034     32 21 04
*Sales Cffice is at 5 Chowringhee Approach, P.O. Princep Street,                    271085
    CALCUTTA 700072
tSales office is at Novelty Chambers, Grant Road, MUMBAI 400007                     309 65 28
$Sales Office is at ‘F’ Block, Unity Building, Narashimaraja Square,                222 39 71
   BANGALORE 560802
                                                         Dee Kay Printers, New Delhi, India
            AMENDMENT NO. 3 DECEMBER 1997
                               TO
       IS 800 : 1984 CODE OF PRACTICE FOR GENERAL
                                                                                              SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                              LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                    CONSTRUCTION IN STEEL
                         (SecondRevision)
I
!
        ( Page 17, clause 1.4 ) -Substitute
    1.4 Refetpnce
                                                  the following for the existing clause:
!
    ?A.1 nt      fmJv&?g    LAisn
                            A..“.“..   Ciwl.n&
                                       w.Y..SY.     plt*;n
                                                     “I..“*..    Y.“.’ “I_ ruhbh
                                                                 nmwn’cinm  V,Y.W.. thmunh
                                                                                    ‘“.“‘p.
i
    reference in this text, constitute provision of this standard. At the time of
4   pubkation, the editions indicated were valid. AI1 standards ate subject to
    revision, and parties to agreements based on this standard are encouraged to
    investigate the possibility of applying the most recent editions of the standards
    indicated below:
      is No.                                           Titi.??
    456 : 1973             Code of practice for plain and reinforced concrete (third
                           revkim      )
    6% : 3972              Code of practice for general engineering drawings ( second
                           rev&& )
    786 : 1967             (Supplement) SI supplement to Indian Standard
                           conversion factors and conversion tables (fort revi.rion )
    812 : 1957             Glossaty of terms relating to welding and cutting of
                           metals
    813 : 1966             Scheme of symbols for welding
    814 : 1991             Covered electrodes for manual metal arc welding of
                           carbon and carbon nranganese steel (fifilr revision)
    816 :1%9               Code of practice for use of metal arc welding for general
                           construction in mild steel (fist revision )
    817 : 1966             Code of practice for training and testing of metal arc
                           welders ( revised )
Amend No. 3 to IS 800 : 1984
  IS No.                                         Tide
819 : 1957               Code of practice for resistance spot welding for light
                         assemblies in mild steel
                                                                                       SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                       LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
819 (Patta 1 and 2) :    IS0 system of limits and tits
 1993
875(Parts 1 to 5 ) :     Code of practice for design loads (other than earthquake)
 1987                    for buildings and structures
961: 1975                Structural steel (high tensile) ( second revision )
962 : 1989               Code of practice for architectural and building dra\ivings
                         (second revision)
1024 : 1979              Code of practice for use of welding in bridges and
                         structures subject to dynamic loading (first revision )
1030 : 1989              Carbon steel castings for general engineering purposes
                         ( fuurth revision )
1148 : 1982              Hot tolled steel rivet tots (up to 40 mm diameter) for
                         structural purposes (I/Ii@ revision)
1149 : 1982              High tensile steel rivet baa for structutnl putposes (third
                         rt!ViriWl)
1261: 1959               Code of practice for seam welding in mild steel
1278 : 1972              Filler rods and wins for gas wekting (second revi.rio~)
1323 :1982               Code of practice for oxy-acetyIene welding for stru&tnI
                         work in mild steel ( second revision )
 _ __ -
llrW(Parts 1 to   3j :   Hexagon   head baits, screws and nuts of product grade C
  1992
1364 (Parts 1 to 5) :    Hexagon head bolts, screws and nuts of product grade A
 1992                    and B
1367 (Parts 1 to 18)     Technical supply conditions for threaded steel fasteners
1393 : 1961              Code of practice for training and testing of oxy-acetylene
                         welders
                                          2
                                                     Aruend No. 3 to IS 800 : 1984
       ISNo.                                        Titk
    1395 : 1982          Molybdenumand chromiummolybdenum vanadiumlow
                         alloy steel electrodes for metal arc welding (fhird
                         WViSiOtt)
                                                                                          SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                          LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
    l477CParts land2):   code of practice for painting of ferrous metals in
      l97i               buildings
I                        Criteria for earthquake resistant design of structures
I   1893 : 1984
                         (fourth revision)
    1929 : 1982          Hot forged steel rivets for hot closing (12 to 36 mm
i                        diameter)(first revision )
r                        Structuralsteel (ordinaryquality) (second revision )
!   1977 : 1975
;   2062 : 1992          Steel for genera1 structural purposes &r&t revision)
                         (supersadesIS 226 : 1975)
i   2155 : 1982          Cold forged solid steel rivets for bot closing (6 to 16 mm
                         diameter)CfVf revision)
    3613 : 1974          Acceptance tests for wire-flux combinations for
                         submerged-arcwelding of stnrchml steels &iwsrrevision)
    3640 : 1982          Hexagon fit bolts Cfirstrevision)
    3757: 1985           High-strengthStNctUKil     bolts (second revision)
    4000 : 1992          High   strength bolts in steel   structures- Code of practice
                         cfusrrevision)
    5369 : 1975          General requirementsfor plain washers and iock washers
                         ( fwsr revision )
    5370 : 1969          Plain washerswith outside diameter3 X inside diameter
    5372 : 1975          Taperwashersfor channels @MC) (fwssitevis~n )
    5374 : 1975          Taperwashers for I-beams @MB) (fwst revision )
    6419 : 1971          Welding rods and bare electrodes for        gas   shielded arc
                         welding of StNCtUfSl steel
                                           3
Amend No. 3 to IS 800 : 1984
     IS No.                                              Title
6560 : 1972                 Molybdenumand chromium-molybdenumlow alloy steel
                            weld@ rods and base electrodes for gas shielded arc
                                                                                                       SUPPLIED BY BOOK SUPPLY BUREAU
                                                                                                       LICENSED TO M. S. UNIVERSITY, VADODARA, FOR INTERNAL USE AT THIS LOCATION ONLY
                            welding
6610 : 1972                 Heavy washers for steel stNctures
6623 : 1985                 High strengthstructuralnuts (fist revision )
6639 : 1972                 Hexagon bolts for steel structures( to be withdrawn)
6649 : 1985                 Hardened and tem_peredwashers for high strength
                            stNctuta1bolts mluinuts (fist tevisios, )
7205 : 1974                 Safety code for erectionof structuralsteel work
7215 : 1974                 Tolerances for fabricationof steel structures
7280 : 1974                 Bare wire elechxles for submerged arc welding of
                            StNctWiiisteels
7307 (part 1) :             Approval tests for welding pdurcs                      : Part1 Fusion
 1974                       welding of steel
73 10 (Part 1) :            Approval tests for welders working to approved weld&
 1974                       procedures: Pati 1 Fusion welding of steel
73l$(Partl):                Approval tests for welders when welding procedure
 1974                       approvalis not required: Part 1 Fusion welding of steel
8500 : 1991                 StNctWll steel - Micro alloyed (medium and high
                            strengthqualities) (/&St revision )
95% : 1980                  Recommendations for metal arc welding of carbon and
                            carbon manganesesteels
        NOTES      1. la lieu of IS 2062 : 1992 supersedingIS 226    : 1975, replace IS 226 : 1975
        by IS 2062 whcrevcrappear in the text of the standad.
        2 Wherever an Indian Standard is referred in the text, the versioa indicated ia 1.4 shall be
        followed.
(CED7)                                   Printed