This lab test report summarizes water quality test results for a sample collected from a concrete plant water tank on January 25, 2018. The sample was received and tested on January 25-26, 2018. Key parameters tested included pH, conductivity, chloride content, sulfate content, total suspended solids, and total dissolved solids. Test results found the pH was 6.5, chloride content was 21.0 mg/L, and sulfate content was 13.6 mg/L. All other parameters were not tested or not detected. The report was certified by the chemist at CECB Laboratory Services.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
75 views1 page

Water 3

This lab test report summarizes water quality test results for a sample collected from a concrete plant water tank on January 25, 2018. The sample was received and tested on January 25-26, 2018. Key parameters tested included pH, conductivity, chloride content, sulfate content, total suspended solids, and total dissolved solids. Test results found the pH was 6.5, chloride content was 21.0 mg/L, and sulfate content was 13.6 mg/L. All other parameters were not tested or not detected. The report was certified by the chemist at CECB Laboratory Services.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Lab Test Code

Sample Received on
w 1802s
2U8-Ar2s
Date of Report
Date of Test
For Construction
2A18-01-26
2018-01-25

Project Coionibo Port City Development project


Glient's Reference
Sample ldentificaUon ]PCDP-WATER-OO3
Location Reference Concrete Plant Water Tank
Sampling by
Description of Sample ear arg C:cr.ess Date of Sampling 2A1g-01-25
Q u a ntitative P arameters

':,._al#
;)t:.*i:"|.
lrlethod,:,')rr,:l,l,ii ailt?ii .mq
.:::.

pH at 22.3 oC
ASif,1 D 1233-99 6.5 >4

Conductivity APHA 251 O-B pS/cm


=lectrical NT not defined

Turbidity USEPA 1 80.1 NTU NT not defined

Soof
3hloride (Cl-) Content ASTN,I D 512-04 mg/L 21.0 '1000'
4500"
sulphate (s042) content ASTM D 516-07 mg/L tJ.b 2000
rhosphate (as P2O5) APHA.45OO-P.E mg/L NT 100

,\ J 3LY 1:: '\ -: . J-. -:.1 \.^'-


r F. -iJ_- t_.j.J mg/L NT 500

umic matter BS EN 10C3: 2002 NT


'otal
Suspended Solids (TSS) APHA-254--D mg/L 1 not defined

Total Disscived Solid ODS) APHA.254O-C mg/L 14 2000"

Carbonate (CO32) Content USGS - 06 lvlethod mg/L ND

I 000"
Bicarbonate (HCOa ) Content USGS - 06 Method mg/L 26.4

" Prestressed concrete or grout


' Concrete with reinlorcement or embedded metal
n
Ccncrete vrithout reinforcement or embedded metal

AThe
colour should be lighterthan yellowlsh brown * BS EN 1008: 2002 - Mixing water for concrete
ND - Not Detacted
"BS 3148 :1980 - Water for making concrete
NT - Not Tested

Abbreviations:
ASTM-Amedcan Soclety for Testing and Materlals lnternational
IAPHA-American Public Health Associatjon I usEpA-united states Environmental protection
Agency I SLS-Sri Lanka Standards lnstitution BS EN-British Standard European
I Norm

D.D.P.N. Jayamaha

Tech.Assistant
Tested By
"'Y(ru\
Chemist
Checked Bv
W
Chemist
Certified By
CECB Laboratory Services
CENTRAL ENGINEERING CONSULTANCY BUREAU

No. 11, Jawatta Road, Colombo S.

Sri Lanka.