0% found this document useful (0 votes)
455 views2 pages

OFV-505 Sensor Head: Ultimate Performance Vibrometer

The OFV-505 sensor head is a laser vibrometer used to precisely measure vibrational velocity and displacement of structures. It integrates interferometer, laser and imaging optics into a stable housing. It achieves the highest signal quality when used with the OFV-5000 vibrometer controller. The sensor head uses a helium-neon laser, has an auto and remote focus capability, and is well-suited for long measurement distances and dark surfaces.

Uploaded by

guy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
455 views2 pages

OFV-505 Sensor Head: Ultimate Performance Vibrometer

The OFV-505 sensor head is a laser vibrometer used to precisely measure vibrational velocity and displacement of structures. It integrates interferometer, laser and imaging optics into a stable housing. It achieves the highest signal quality when used with the OFV-5000 vibrometer controller. The sensor head uses a helium-neon laser, has an auto and remote focus capability, and is well-suited for long measurement distances and dark surfaces.

Uploaded by

guy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

OFV-505 Sensor Head

Polytec's OFV-series single point laser vibrometers deter-


mine vibrational velocity and displacement of structures
quickly and very precisely.

The sensor head OFV-505 integrates interferometer,


laser and imaging optics in a stable housing.

The sensor head achieves its highest signal quality


when combined with the digital OFV-5000 Vibrometer
Controller.

Highlights
■■ Fast and low-noise results thanks

to auto and remote focus


■■ Well-suited for dark surfaces and

long measurement distances


■■ Flexibility thanks to variable work-

ing distance and interchangeable


lenses
■■ Visible laser spot ensures easy

alignment and focusing


■■ Eye-safe laser

OFV-505 Sensor Head


Ultimate Performance Vibrometer
Datasheet
Technical Data
Optical Specifications

Laser type Helium Neon (HeNe)

Laser class Class 2, < 1 mW, eye-safe

Laser wavelength 633 nm, visible red laser beam

Focus Auto focus, remote focus, manual focus 1

Maximum stand-off Up to 300 m (with OFV-SLR, surface dependent)


distance

Visibility maxima 234 mm + n · 204 mm; n = 0, 1, 2, 3, … measured from the focusing ring
Laser Radiation
General Specifications Do not stare into beam
Class 2 Laser Product
According to IEC/EN 60825-1 (2008)
Operating temperature +5 °C … +40 °C (41 °F ... 104 °F) Complies with 21 CFR 1040.10 and 1040.11
except for deviations pursuant to
Laser Notice no. 50, dated 24 June 2007
Relative humidity Max. 80%, non-condensing P  1 mW/cw;  = 633 nm

Weight 3.4 kg

Dimensions [W x H x L] 120 x 80 x 345 mm (4.7 x 3.2 x 13.6 in)

Controller OFV-5000, OFV-2520, OFV-2570 Vibrometer Controller,


compatibility VDD-E-600 Digital Front-End

Compliance with Standards

Laser safety IEC/EN 60825-1; CFR 1040.10 and 1040.11

Electrical safety IEC/EN 61010-1

EMC IEC/EN 61326-1

Options and Accessories


Polytec offers a wide range of ac-
Front lens OFV-SR OFV-MR OFV-LR2 OFV-SLR cessories including tripods, tilt and
short range mid range long range super long range traverse stages for mounting and
Focal length [mm] 30 60 100 200 positioning fiber heads.

Min. stand-off distance [mm] 100 200 530 1,800


Please contact your local vibrometer
Aperture diameter (1/e ) [mm]
2
3.4 6.8 11.3 22.6 sales engineer or visit our website
Typical spot size in μm at www.polytec.com/vibrometers
100 mm 25 - - - for more detailed information.
200 mm 49 25 - -
500 mm 121 54 18 -
1,000 mm 245 112 62 -
2,000 mm 500 235 135 60
3,000 mm 750 356 210 96 1
OFV-503 model available without
5,000 mm distance 1,260 604 356 168 auto focus and remote focus.
Each additional meter add [μm] 240 126 74 36 2
Default configuration

Polytec GmbH Polytec, Inc. (USA) Polytec Ltd. Polytec Japan Polytec China Ltd.
(Germany) North American (Great Britain) Arena Tower, 13th floor Room 402, Tower B
Polytec-Platz 1-7 Headquarters Lambda House 3-1-9, Shinyokohama Minmetals Plaza
76337 Waldbronn 16400 Bake Parkway Batford Mill Kohoku-ku, Yokohama-shi No. 5 Chaoyang North Ave
Tel. +49 7243 604-0 Suites 150 & 200 Harpenden, Herts AL5 5BZ Kanagawa 222-0033 Dongcheng District
2017/01 - Technical specifications are subject to change without notice.

info@polytec.de Irvine, CA 92618 Tel. +44 1582 711670 Tel. +81 45 478-6980 100010 Beijing
Tel. +1 949 943-3033 info@polytec-ltd.co.uk info@polytec.co.jp Tel. +86 10 65682591
Polytec GmbH info@polytec.com info-cn@polytec.com
(Germany)
Vertriebs- und Central Office Polytec France S.A.S. Polytec South-East Asia
Beratungsbüro 1046 Baker Road Technosud II Pte Ltd
Schwarzschildstraße 1 Dexter, MI 48130 Bâtiment A Blk 4010 Ang Mo Kio Ave 10
12489 Berlin Tel. +1 734 253-9428 99, Rue Pierre Semard #06-06 TechPlace 1
Tel. +49 30 6392-5140 92320 Châtillon Singapore 569626
OM_DS_OFV-505_E_42347

East Coast Office Tel. +33 1 496569-00 Tel. +65 64510886


1 Cabot Road info@polytec.fr info@polytec-sea.com
Suites 101 & 102
www.polytec.com
Hudson, MA 01749
Tel. +1 508 417-1040