VKK1-4,
Data Sheet
VKK1R-4
Junction boxes
Special features
− Parallel connection of up to
4 load cells
− Off-center load compensation via
VKK1-4 integrated resistor network
− EMC-tested per EN 45 501 and
EN 61 323 through HBM shielding
design
− Degree of protection IP65 to
EN 60 529
− VKK1R-4 with stainless housing
VKK1R-4
Dimensions (in mm; 1 mm = 0.03937 inches)
VKK1R-4
179
163 a.f. 14
45
18
6
84
52
Mounting direction 30
* depending on the cable type
Grounding screw
50...100*
M5x10 DIN 84
Scope of supply includes:
1 piece of special screws for cable
∅ 4...6.5 diameter 7.5 mm, a.f. 17
Suitable fastening screws: M4 DIN 84 or B3.9 DIN 7971 (minimum screw length 20 mm)
B2287-1.1 en
Dimensions VKK1R-4 (in mm; 1 mm = 0.03937 inches)
186 110
M4
36
176 100
204 125
190
7
Mounting direction
5x M12, a.f.14,
for cable ∅ 4 ... 6.5 mm
Specifications
Type VKK1-4 VKK1R-4
Resistor network for off-center load compensation Ω 0.39...5.71 (in 15 steps)
Max. permissible voltage V 18
Nominal temperature range −20...+85 [−4...+185]
Operating temperature range °C
C [[°F]
F] −20...+85 [−4...+185]
Storage temperature range −40...+85 [−40...+185]
EMI test
Electromagnetic field (26...1000 MHz) V/m 10
Burst (to connected cables) V 1000
Electrostatic discharge (to housing) V 6000
Weight, approx. kg 1 1.5
Max. wire cross section of cable strands mm2 1.5
Degree of protection according to EN 60529 (IEC 529) IP65 (dust−tight and protected against water jets)
Materials Housing Diecast aluminum, coated Stainless steel
(color: RAL 7035)
Sleeve nut PG7, SW14, M12, SW14,
nickel−plated brass nickel−plated brass
Clamping cone Neoprene, Neoprene,
for cable−∅ 4...6.5 mm1) für cable−∅ 4...6.5 mm
1) Scope of supply includes: 1 piece of special screws for cable diameter 7.5 mm, a.f. 17
HBM 2 B2287-1.1 en
Resistor network in the junction box for off-center load compensation with 4 load cells
Input: Output:
Load cells 1 ... 4 Amplifier
Sense (+)
Excitation (+)
4 3 2 1
Excitation (−)
Sense (−)
0.39 Ω 0.39 Ω 0.39 Ω 0.39 Ω
0.82 Ω 0.82 Ω 0.82 Ω 0.82 Ω
1.50 Ω 1.50 Ω 1.50 Ω 1.50 Ω
3.00 Ω 3.00 Ω 3.00 Ω 3.00 Ω
Signal (−)
Signal (+)
Function of the intgrated resistor network
The resistor network enables off-center load compensation for a scale to be easily made, if required.
Three steps have to be taken:
1. Load scale corners.
2. Read correction value from diagram (mounting instructions).
3. Activate compensation resistor.
B2287-1.1 en 3 HBM
Survey of HBM junction boxes
Number of Degree
Type Signal load cells that of Housing EMC
can be protec- material protec-
connect tion tion
VKK1-4 Analog 2 ... 4 IP65 Alumin. yes
Order no.: diecast
1-VKK1-4A
VKK1R-4 Analog 2 ... 4 IP65 Stainless yes
Order no.: steel
1-VKK1R-4
VKK2-8 Analog 3 ... 8 IP65 Stainless yes
Order no.: steel
1-VKK2-8
Sheet
VKK2R-8 Analog 3 ... 8 IP65 steel, yes
Order no.: powder
1-VKK2R-8 coated
VKK2R-8EX Analog 3 ... 8 IP65 Stainless yes
Order no.: steel
1-VKK2R-8EX
VKK2R-8 DIGITAL Digital 3 ... 8 IP65 Stainless yes
Order no.: steel
1-VKK2R-8DIGITAL
Modifications reserved. Hottinger Baldwin Messtechnik GmbH
All details describe our products in general form only. They
are not to be understood as express warranty and do not
constitute any liability whatsoever.
Im Tiefen See 45, D-64293 Darmstadt, Germany
Tel.: +49 6151 803−0; Fax: +49 6151 8039100
B2287-1.1 en E−mail: support@hbm.com www.hbm.com