0% found this document useful (0 votes)
368 views10 pages

Spectra™ Tubing Cutters Field Assembly and Arming: January 21, 2010

Uploaded by

ali
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
368 views10 pages

Spectra™ Tubing Cutters Field Assembly and Arming: January 21, 2010

Uploaded by

ali
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

SPECTRA™ TUBING CUTTERS

FIELD ASSEMBLY and ARMING

January 21, 2010

1.0 DESCRIPTION
1.1 Titan Spectra™ Tubing Cutters (see Page 9 for specifications) are designed for
maximum interchangeability with accessory equipment commonly used in
operating commercial Tubing Cutters in the field:
a) The top of the Cutter Assembly (Fig. 1, Page 6) is equipped with the
commonly used 1-3/16”–12 2B threads for connecting to most Extension
Mandrels/Shock Subs being used in the field. A size 568-214 Viton O-ring is
employed for sealing.
b) Rubber Sleeve (GPR-56659) is used for mounting the Detonator (DETO-
A161-AP or equivalent).
c) Connection from the Extension Mandrel to Firing Head/CCL/or other device is
at the option of the user. However, certain specific Safe Arming Procedures
are essential, as detailed in Section 2.0 and 3.0.
1.2 Tubing Cutters are PREASSEMBLED with Booster and all necessary internal
components and therefore ready for assembly and arming at the wellsite.
Note: It is not recommended to disassemble this Tubing Cutter. Should
disassembly be required for some reason, RETURN THE DEVICE TO THE
MANUFACTURER.
1.3 One inline Bow Spring Centralizer must be mounted immediately above the Tubing
Cutter (or Shock Mandrel) and one between the Cablehead and the Weight Bar(s)
to ensure a properly positioned (centralized) toolstring. A centralizer to assure
maximum performance is permanently mounted on the bottom of the tool.
1.4 Several methods of arming the Tubing Cutter are described in Section 2.0 and 3.0.

See Figures 1, 2 & 3 on Pages 6, 7 and 8 for pictorial assembly details.

See the SPECTRA™ Tubing Cutter chart on Page 10 for the selection of the proper
Tubing Cutter for common applications.

143 HCR 4361 • Milford, Texas 76670 • Tel 972.493.2580 • Sales 800.320.5110 • Fax 972.493.2300
Titan Specialties, Ltd. – Energetics Division
Page 1 of 10
Accessory Components
Item Part number Description
HES-100158266 Aluminum shock sub w/o button contact, grooved, 1-3/16”–12 2B
1A
(*or 9000-150-011) box up X 1-3/16”–12 2A pin down. 15,000 PSI limit
HES-100008258 Aluminum shock sub with button contact, grooved 1-3/16”–12 2B
1B
(*or 9000-150-010) box up X 1-3/16”–12 2A pin down. 15,000 PSI limit
Steel HP isolation bar, ungrooved, 12” long 1-3/16”–12 2B box
1C 9000-150-030
up X 1-3/16”–12 2A pin down for all services up to 25,000 PSI
2 0111-214-V95 O-Ring 568-214 Viton, 95 durometer
3 GPR-56659 Rubber sleeve (used with 6A)
6A DETO-A161-AP Detonator, A161 or equivalent
Detonator, D1208-P (or equiv.) includes rubber sleeve and
6B DETO-D1208-P
spring contact assembly
7 9000-150-022 Safety Sub
8 3924-12P-FBE Steel Thread Protector (used as Shunt Plug)

(1A, 1B *Denotes previous, equivalent part numbers. 1C for HP applications; also recommended for standard
service).

2.0 FIELD ASSEMBLY / THROUGH MANDREL / ARMING PROCEDURE

This section for use with an Extension Mandrel (user supplied) or HES-
100158266 Shock Sub (without button contact). See Fig, 1 & 2 on Page 6 and 7
for details.

2.1 Pre-check electric cable circuit, cable head, CCL and any adapters for electrical
continuity and insulation prior to off-loading the Tubing Cutter Assembly (See API
RP 67).
2.2 Turn off radios, welders, cathodic protection devices (in accordance with RP 67);
turn off generator of perforating unit; be sure cable Safety Switch is in SAFE mode;
measure stray voltages between unit to ground, rig to ground and wellhead to
ground, ensuring no stray voltages are present. Electrically bond perforating unit,
rig and wellhead with grounding straps.
ENSURE THAT NO VOLTAGE IS PRESENT BETWEEN CABLE CONDUCTOR
AND GROUND, USING AN APPROVED BLASTER’S MULTIMETER.
2.3 Remove Detonator (DETO-A161-AP or equivalent) from proper storage and install
into Rubber Sleeve (GPR-56659) as shown in Fig. 2A, assuring that detonator
leads remain shorted.
Make sure that the detonator length is set correctly as indicated in Fig. 2A, and
shown below:
2-1/2" -- 63 mm

143 HCR 4361 • Milford, Texas 76670 • Tel 972.493.2580 • Sales 800.320.5110 • Fax 972.493.2300
Titan Specialties, Ltd. – Energetics Division
Page 2 of 10
2.4 Feed Detonator wires through Extension Mandrel Fig. 2B, and install Rubber
Sleeve over end of Extension Mandrel as shown in Fig. 2C.
2.5 Install Safety Sub onto Extension Mandrel (over Detonator), hand tight only. Cut
Detonator wires to proper length for connection. Then connect Detonator wires to
Connecting Device one lead to power, one to ground (Fig. 2D). The ground
connection should be a positive one, such as provided by a 10-32 screw. (NOTE:
Many failures to fire [misruns] are caused by a defective ground connection).
2.6 Make-up Extension Mandrel to Connecting Device, assuring that loose wires are
not damaged by threads or mechanical connection. Electrical continuity of the
detonator ground circuit and detonator resistance value should be reconfirmed at
this time with an approved Blaster’s Multimeter.
2.7 BE SURE SAFETY KEY IS VISIBLE AT THE ARMING SITE. Assure that no
voltage exists at the bottom electrical connection of the wireline tools or cablehead.
Attach the Connecting Device to the cablehead (or wireline tools).
2.8 Remove the Safety Sub.
2.9 Carefully install the Tubing Cutter Assembly over the Detonator Assembly; snug-up
the threads with a non-sparking wrench, assuring that 568-214 Viton O-ring is in
place (Fig 2E).
2.10 The Tubing Cutter Assembly is ready to run in the hole.
Note: When checking Detonator circuit electrically:
a) Use an approved Blasting Multimeter;
b) Assure that the Detonator is either contained within a Detonator Safety Tube
or the Safety Sub during any test.

3.0 FIELD ASSEMBLY / PREWIRED DETONATOR ARMING


PROCEDURE
This section for use with HES-100008258 Shock Sub with button contact. See
Fig. 1 & 3 on Page 6 and 8 for details.

3.1 Pre-check electric cable circuit, cable head, CCL and any adapters for electrical
continuity and insulation prior to off-loading the Tubing Cutter Assembly (See API
RP 67).
3.2 Turn off radios, welders, cathodic protection devices (in accordance with RP 67);
turn off generator of perforating unit; be sure cable Safety Switch is in SAFE mode;
measure stray voltages between unit to ground, rig to ground and wellhead to
ground, ensuring no stray voltages are present. Electrically bond perforating unit,
rig and wellhead with grounding straps.
ENSURE THAT NO VOLTAGE IS PRESENT BETWEEN CABLE CONDUCTOR
AND GROUND, USING AN APPROVED BLASTERS MULTIMETER.
3.3 Install Firing Head (with Steel Thread Protector - 3924-12P-FBE installed) into top
of Shock Sub hand tight (Fig. 3A). The Thread Protector acts as an electrical
Shunt Plug, and must be utilized.

143 HCR 4361 • Milford, Texas 76670 • Tel 972.493.2580 • Sales 800.320.5110 • Fax 972.493.2300
Titan Specialties, Ltd. – Energetics Division
Page 3 of 10
3.4 Remove detonator (DETO-D1208-P, or equivalent) with rubber sleeve and spring
contact from proper storage.
Make sure that the detonator length is set correctly as indicated in Fig. 3B, and
shown below:

2-1/2" - 63 mm.

Shunt
Wire

3.5 Remove the Shunt wire and moisture seal tape from the detonator (Fig. 3B) and
install the detonator onto Shock Sub (Fig. 3C). Uncoil enough of the ground wire
from the small diameter of the boot to provide 2” (50.8 mm) of wire above the large
diameter of the boot when it is extended from the small diameter and formed over
the edge of the large diameter.
Wrap the ground wire clockwise, looking from the detonator end, into the O-ring
groove above the boot. Push the 568-020 O-ring up into the groove assuring that
the end and about 2” (50 mm) of ground wire is retained between O-ring and
mandrel (Fig. 3C).
3.6 Install Safety Sub (9000-150-022) onto Shock Sub (over detonator), hand tight only
(Fig. 3-D). Remove the Steel Thread Protector / Shunt Plug from top and confirm
electrical continuity and detonator resistance value. Re-install Steel Thread
Protector / Shunt Plug until assembly is ready for installation to the cablehead (or
wireline tools).
3.7 BE SURE SAFETY KEY IS VISIBLE AT THE ARMING SITE. Assure that no
voltage exists at the bottom electrical connection of the wireline tools or cablehead.
Remove Steel Thread Protector/Shunt Plug and connect firing head to the wireline
tools or cablehead. This connects the detonator lead to the hot wire.
3.8 Unscrew Safety Sub and carefully install the Tubing Cutter Assembly over the
Detonator Assembly and snug threads with a non-sparking wrench. Assure that
568-214 Viton O-ring is in place (Fig. 3-E).
3.9 The Tubing Cutter is ready to run in the hole.
Note: When checking Detonator circuit electrically:
a) Use an approved Blasting Multimeter;
b) Assure that the Detonator is either contained within a Detonator Safety Tube
or the Safety Sub during any test.

143 HCR 4361 • Milford, Texas 76670 • Tel 972.493.2580 • Sales 800.320.5110 • Fax 972.493.2300
Titan Specialties, Ltd. – Energetics Division
Page 4 of 10
4.0 DISARMING THE TUBING CUTTER ASSEMBLY

4.1 Prior to going into the well


4.1.1 Remove Tubing Cutter Assembly (by unscrewing) from Extension
Mandrel.
4.1.2 Install Safety Sub over detonator, hand tight.
4.1.3 Remove Extension Mandrel from Connecting Device; remove Safety Sub,
remove Detonator and return the Detonator Assembly to proper storage.
4.2 After running into the well
4.2.1 Follow reverse procedure as that outlined in 3.0 or 4.0 above. If
connections prove hard to break (reflecting high torque), STOP. Call your
Field Technical Representative for assistance.

143 HCR 4361 • Milford, Texas 76670 • Tel 972.493.2580 • Sales 800.320.5110 • Fax 972.493.2300
Titan Specialties, Ltd. – Energetics Division
Page 5 of 10
Fig. 1 –Tubing Cutter Arming Options (Detonator not included)

Through Mandrel Arming Option Pre-wired Detonator Arming Option

Extension Shock Sub Shock Sub with


Mandrel Without Button Contact
(user supplied) Button Contact 9000-150-010
9000-150-011

Rubber
Sleeve
GPR-56659 Detonator
DETO-D1208-P

Plastic
Protector

1.187-12UN

Optional
arming
Do Not
Unscrew
Do Not
Unscrew

143 HCR 4361 • Milford, Texas 76670 • Tel 972.493.2580 • Sales 800.320.5110 • Fax 972.493.2300
Titan Specialties, Ltd. – Energetics Division
Page 6 of 10
Fig. 2 – Through Mandrel Arming

2-1/2" -- 63 mm

Fig. 2A - Install Detonator into sleeve as shown

Fig. 2B - Feed Detonator wires through Extension Mandrel

Fig. 2C - Install rubber sleeve over Extension Mandrel as shown

Fig. 2D - Install Safety Sub over Detonator, cut wires to length and attach Detonator wires to
firing head. Make up Extension Mandrel to firing head.

Fig. 2E - Remove Safety Sub and install Tubing Cutter Assembly

143 HCR 4361 • Milford, Texas 76670 • Tel 972.493.2580 • Sales 800.320.5110 • Fax 972.493.2300
Titan Specialties, Ltd. – Energetics Division
Page 7 of 10
Fig. 3 – Pre-Wired Detonator Arming

Shunt
Plug

Fig. 3A - Install Shunt Plug to Shock Mandrel.


568-020 O-ring
2-1/2” – 63 mm
Contact Spring

Ground Wire
Remove Shunt Wire

Fig. 3B - Remove Shunt Wire before installing Detonator.

Wrap Gound Wire In Groove


Slide 020 O Ring Over Wire

Shunt
Plug

Ground
Wire

Fig. 3C - With Shunt Plug in place, install Detonator Assembly over Shock Mandrel as shown.

Electrical
Connection

Safety Sub

Fig. 3D - Install Safety Sub, remove Shunt Plug, install Firing Head and connect Firing Head to

wireline tools or cablehead.

Fig. 3E - Remove Safety Sub and install Tubing Cutter Assembly.

143 HCR 4361 • Milford, Texas 76670 • Tel 972.493.2580 • Sales 800.320.5110 • Fax 972.493.2300
Titan Specialties, Ltd. – Energetics Division
Page 8 of 10
Spectra Summary Chart
Cutters (excluding CoiledTubing) are availble to utilize the JRC RED Top Fire Detonator (Version III or IV). Specify RED after the part number.
Pressure
Approx.
HMX Hazard Rating Calculated Rev. Date:
DOT CE Part Number Application Pipe
(grams) Class for I Hr. @ I. D. 1/15/10 JJ
Weight / Ft.
400° F.
SCP-0687T001 2 1.4S 18,000 PSI CT 1.00" O.D. x .080" - .109" wall .788 TO 1.040 LB/FT .840" - .782"
SCP-0800T001 3 1.4S 18,000 PSI CT 1.25" O.D. x .156" wall 1.827 LB/FT .938"

Coiled Tubing
SCP-0820T001 3 1.4S 18,000 PSI CT 1.25" O.D. x .156" wall 1.827 LB/FT .938"
SCP-0875T001 3 1.4S 18,000 PSI CT 1.25" O.D. x .080" - .125" wall 1.002 TO 1.506 LB/FT 1.090" - 1.000"
SCP-1000T001 3 1.4S 18,000 PSI CT 1.50" O.D. x .095" - .190" wall 1.429 TO 2.665 LB/FT 1.310" - 1.120"
SCP-1188T001 6.25 1.4S 18,000 PSI CT 1.75" O.D. x .109" - .204" wall 1.915 TO 3.377 LB/FT 1.532" - 1.342"
SCP-1250T001 6.25 1.4S 18,000 PSI CT 1.75" O.D. x .109" - .204" wall 1.915 TO 3.377 LB/FT 1.532" - 1.342"
SCP-1375T001 7 1.4S 18,000 PSI CT 2.00" O.D. x .109" - .204" wall 2.207 TO 3.923 LB/FT 1.782" - 1.592"
SCP-1580T001 12 1.4S 18,000 PSI T 2-3/8" O.D. x .218" wall 5.01 / FT 1.939"
SCP-1580T101 38 1.4D 18,000 PSI T 2-3/8" O.D. x .218" wall 5.01 / FT 1.939"
SCP-1680T001 12 1.4S 18,000 PSI T 2-3/8" O.D. x .218" wall 5.01 / FT 1.939"
SCP-1813T001 12 1.4S 18,000 PSI T 2-3/8" O.D. x .218" wall 5.01 / FT 1.939"

Standard Cutters
SCP-2063T001 17 1.4S 18,000 PSI T 2-7/8" O.D. x .276" wall 7.90 / FT 2.323"
SCP-2125T001 17 1.4S 18,000 PSI T 2-7/8" O.D. x .276" wall 7.90 / FT 2.323"
SCP-2125T101 38 1.4D 18,000 PSI T 2-7/8" O.D. x .276" wall 7.90 / FT 2.323"
SCP-2250T001 22.7 1.4S 18,000 PSI T 2-7/8" O.D. x .276" wall 7.90 / FT 2.323"
SCP-2250T101 38 1.4D 18,000 PSI T 2-7/8" O.D. x .276" wall 7.90 / FT 2.323"
SCP-2500T101 28.33 1.4D 18,000 PSI T 3-1/2" O.D. x .375" wall 12.95 / FT 2.750"
SCP-2650T101 34 1.4D 18,000 PSI T 3-1/2" O.D. x .254" wall 9.20 / FT 2.992"
SCP-2750T001 22.7 1.4S 18,000 PSI T 3-1/2" O.D. x .289" wall 10.20 / FT 2.922"
SCP-2750T101 38 1.4D 18,000 PSI T 3-1/2" O.D. x .289" wall 10.20 / FT 2.922"
**SCP-1680T001 HNS** 12 1.4S 18,000 PSI T 2-3/8" O.D. x .218" wall 5.01 / FT 1.939"

**201 Cutters are not stocked and must


**SCP-1900S001** 20 1.4S 18,000 PSI T 2-7/8" O.D. x .340" wall 9.50 / FT 2.195"
**SCP-2188T101** 36 1.4D 22,000 PSI T 3-1/8" O.D. x .435" wall 12.50 / FT 2.255"
" " " " DP 3-1/2" O.D. x .375" wall 12.95 / FT 2.750"
" " " " DP 3-1/2" O.D. x .449" wall 15.50 / FT 2.602"

Premium Cutters

be ordered**
**SCP-2251T101** 36 1.4D 20,000 PSI DP 3-1/2" O.D. x .476" wall 15.80 / FT 2.548"
**SCP-2252T101** 35 1.4D 20,000 PSI T 3-1/2" O.D. x .460" wall 14.93 / FT 2.580"
**SCP-2375T201** 38 1.4D 18,000 PSI T 3-1/2" O.D. x .425" wall 13.96 / FT 2.650"
**SCP-2500T101 HNS** 38 1.4D 22,000 PSI T 3-1/2" O.D. x .289" wall 10.20 / FT 2.922"
**SCP-2500T201** 38 1.4D 18,000 PSI T 3-1/2" O.D. x .400" wall 13.24 / FT 2.700"
" " " " T 3-1/2" O.D. x .425" wall 13.96 / FT 2.650"
**SCP-2625T101 HNS** 38 1.4D 18,000 PSI T 3-1/2" O.D. x .375" wall 12.95 / FT 2.750"
**SCP-2690T201** 52 1.1D 18,000 PSI T 4-1/2" O.D. x .365" wall 16.12 / FT 3.770"
**SCP-2690T301** 52 1.4D 18,000 PSI T 4-1/2" O.D. x .365" wall 16.12 / FT 3.770"
**SCP-3000T101** 38 1.4D 22,000 PSI PM 4.000" O.D. x .360" wall 14.00 / FT 3.280"
**SCP-3190T301** 59 1.4D 22,000 PSI PM 4.000" O.D. x .360" wall 14.00 / FT 3.280"
**SCP-3250T201** 59 1.1D 22,000 PSI PM 4.535" O.D. x .360" wall 16.05 / FT 3.815"
**SCP-3250T301** 59 1.4D 22,000 PSI PM 4.535" O.D. x .360" wall 16.05 / FT 3.630"
**SCP-3310T201** 59 1.1D 18,500 PSI T 5.00" O.D. x .362" wall 17.93 / FT 4.276"
**SCP-3310T301** 59 1.4D 18,500 PSI T 5.00" O.D. x .362" wall 17.93 / FT 4.276"
**SCP-3375T201** 59 1.1D 22,000 PSI T 4-1/2" O.D. x .410" wall 17.91 / FT 3.680"
" " " " T 5-1/2" O.D. x .420" wall 22.79 / FT 4.660"

**201 Cutters are not stocked and must be ordered**


**SCP-3375T301** 59 1.4D 22,000 PSI T 4-1/2" O.D. x .410" wall 17.91 / FT 3.680"
" " " " T 5-1/2" O.D. x .420" wall 22.79 / FT 4.660"
**SCP-3475T201** 59 1.1D 22,000 PSI T 4-1/2" O.D. x .410" wall 17.91 / FT 3.680"
" " " " T 5-1/2" O.D. x .420" wall 22.79 / FT 4.660"
**SCP-3475T301** 59 1.4D 22,000 PSI T 4-1/2" O.D. x .410" wall 17.91 / FT 3.680"
" " " " T 5-1/2" O.D. x .420" wall 22.79 / FT 4.660"

Premium Cutters
**SCP-3680T201** 59 1.1D 18,000 PSI T 5.00" O.D. x .362" wall 17.93 / FT 4.267"
" " " " T 5.00" O.D. x .478" wall 23.08 / FT 4.044"
**SCP-3680T301** 59 1.4D 18,000 PSI DP 5.00" O.D. x .362" wall 17.93 / FT 4.267"
" " " " DP 5.00" O.D. x .478" wall 23.08 / FT 4.044"
**SCP-3800T201** 109.33 1.1D 18,000 PSI DP 5.00" O.D. x .476" wall 23.00 / FT 4.048"
**SCP-3800T301** 76 1.4D 18,000 PSI DP 5.00" O.D. x .476" wall 23.00 / FT 4.048"
**SCP-4070T201** 109.33 1.1D 22,000 PSI T 5-1/2" O.D. x .500" wall 26.70 / FT 4.500"
**SCP-4070T301** 76 1.4D 22,000 PSI T 5-1/2" O.D. x .500" wall 26.70 / FT 4.500"
**SCP-4150T201** 109.33 1.1D 22,000 PSI T 5-1/2" O.D. x .500" wall 26.70 / FT 4.500"
**SCP-4150T301** 76 1.4D 22,000 PSI T 5-1/2" O.D. x .500" wall 26.70 / FT 4.500"
**SCP-4200T201** 109.33 1.1D 18,000 PSI T 5-1/2" O.D. x .500" wall 26.70 / FT 4.500"
**SCP-4200T301** 76 1.4D 18,000 PSI T 5-1/2" O.D. x .500" wall 26.70 / FT 4.500"
SCP-5250T201 139 1.1D 18,000 PSI C 7.00" O.D. x .500" wall 34.71 / FT 6.000"
SCP-5250T301 75.13 1.4D 18,000 PSI C 7.00" O.D. x .500" wall 34.71 / FT 6.000"
SCP-5375T201 139 1.1D 18,000 PSI C 7.00" O.D. x .500" wall 34.71 / FT 6.000"
SCP-5375T301 75.13 1.4D 18,000 PSI C 7.00" O.D. x .500" wall 34.71 / FT 6.000"
SCP-5700T201 139 1.1D 18,000 PSI C 7.00" O.D. x .500" wall 34.71 / FT 6.000"
SCP-5700T301 75.13 1.4D 18,000 PSI C 7.00" O.D. x .500" wall 34.71 / FT 6.000"
SCP-C3500T301 59 Pending 7,500 PSI C 4.50" O.D. x .205" - .337" wall 9.5 - 15.1 / FT 3.09" - 2.826"
SCP-C3750T301 59 Pending 7,500 PSI C 5.00" O.D. x .223" - .437" wall 11.5 - 21.4 / FT 3.304" - 2.876"

Cutters
P&A
SCP-C4250T301 76 Pending 7,500 PSI C 5.50" O.D. x .244" - .415" wall 14.0 - 23.9 / FT 3.762" - 3.42"
SCP-C5800T301 75.13 Pending 7,500 PSI C 7.00" O.D. x .317" - .408" wall 23.0 - 29.0 / FT 5.166" - 4.984"
SCP-C6250T301 75.13 Pending 6,000 PSI C 7.625" O.D. x .375" - .500" wall 29.7 - 39.0 / FT 5.50" - 5.25"
SCP-1680T001GW 5.9 1.4S 7,000 PSI GWT 2-3/8" O.D. x .218" wall 5.01 / FT 1.939"

Pressure)
Gas Well
SCP-1813T001GW 6.6 1.4S 7,000 PSI GWT 2-3/8" O.D. x .218" wall 5.01 / FT 1.939"

(Low
SCP-2125T001GW 10.3 1.4S 7,000 PSI GWT 2-7/8" O.D. x .276" wall 7.90 / FT 2.323"
SCP-2250T001GW 12 1.4S 7,000 PSI GWT 2-7/8" O.D. x .276" wall 7.90 / FT 2.323"

You might also like