Freezer Repair Guide

This document provides performance specifications for an automatic defrost freezer ice maker, including operating temperatures, pressures, voltages, component details, and wiring connections. Key specifications include an operating time of 40-50% at 70°F ambient and 55-65% at 90°F ambient, a freezer temperature of -3°F to 3°F, low side pressures of 6-12 psig cutting in and -1 to 3 psig cutting out, and a high side pressure of 85-100 psig at 70°F and 120-135 psig at 90°F. Defrost is set for 30 minutes every 12 hours of compressor run time.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
627 views2 pages

Freezer Repair Guide

This document provides performance specifications for an automatic defrost freezer ice maker, including operating temperatures, pressures, voltages, component details, and wiring connections. Key specifications include an operating time of 40-50% at 70°F ambient and 55-65% at 90°F ambient, a freezer temperature of -3°F to 3°F, low side pressures of 6-12 psig cutting in and -1 to 3 psig cutting out, and a high side pressure of 85-100 psig at 70°F and 120-135 psig at 90°F. Defrost is set for 30 minutes every 12 hours of compressor run time.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT MID-POINT service data sheet - 297299800 iCE MAKER INFORMATION

CONTROL SETTING
Capacitor Run or 70°F (21°C) Ambient 90°F (32°C) Ambient
Induction Run STANDARD - AUTOMATIC DEFROST FREEZER Test Cycling
Operating Time 40 to 50% 55 to 65% MODELS (r134a) Remove cover by inserting screwdriver in notch at bottom and
-3° to 3° F -3° to 3° F
Freezer Temperature
-19° to -16° C -19° to -16° C
prying cover from housing. Use screwdriver to rotate motor gear
important safety notice counterclockwise until holding switch circuit is completed. All
Low Side Pressure 6 to 12 psig 6 to 12 psig
(cut-in) 41 to 83 kPa 41 to 83 kPa The information provided herein is designed to assist qualified components of ice maker should function to complete the cycle.
Low Side Pressure -1 to 3 psig -1 to 3 psig repair personnel only. Untrained persons should not attempt to
(cut-out) -4 to 21 kPa -4 to 21 kPa make repairs due to the possibility of electrical shock. Disconnect Water Fill Volume
Water Fill
High Side Pressure 85 to 100 psig 120 to 135 psig power cord before servicing. Adjustment The water fill adjustment
(last 1/3 cycle) 575 to 670 kPa 810 to 910 kPa
Wattage (last 1/3 cycle) 100 to 120 110 to 130 important screw will change the
Motor fill time. One full turn is
Amps (running) .9 to 1.1 1.0 to 1.2 If any green grounding wires are moved during servicing, Gear equal to 20cc (.68 oz.).
Base Voltage 115 vac (127 vac max) they must be returned to their original position and properly
TU The correct fill is 95 to
DEFROST SPECIFICATIONS
secured. R Mounting 105cc (3.2 to 3.6 oz.).

N
Plate
Cabinet Size
Thermostat Heater
Screws When a water valve is
Cut-in Cut-out Watts Ohms caution: All electrical parts and wiring must be replaced, the fill volume
19’ 21° F (-6° C) 42° F (6° C) 550 24 shielded from torch flame. Do not allow torch to contact must be checked.
Electronic Timer - Defrost 30 minutes every 12 hours of compressor run time. insulation; it will char at 200°F. Mounting
Plate
CONDENSER FAN MOTOR
Screw
Timing
Watts RPM Amps Gear
2.3 1100 CW Opposite Shaft 0.13 Running
NOTE: Products come equipped with an Electronic Defrost
Control. To initiate defrost, press and hold air filter and alarm
ICE MAKER SPECIFICATIONS
reset key simultainiously for three seconds. To terminate defrost,
Electrical 115 vac (127 vac max) 60 Hertz
press and hold air filter and alarm reset key simultainiously for
Opens at 48° F ( 9° C), Closes at 15° F ( -9° C) three seconds
Thermostat
Models with orange wire close at 8.96° F (-12.8° C)
LINE POWER NEUT RAL
Heater Wattage 165
ICE MA KER

BLK
ICE MAKER CONNECTOR PLUG CONNECTIONS

YEL
B LK BRN

ICE MAKER
Wire Number Wire Color Connects to: P-3
THER MAL
1 Green/Yellow Ground CUT-OUT

2 Yellow Water Valve MOTOR

BLK
3 Black Line HO LD

ICE MAKER
SW ITCH YEL
4 Light Blue Neutral RED P-4

YEL
T HERMOSTAT

WATER VALVE
RED
BLK BLU

GRN / yEL
MOLD HEATER
SHUT-OF F

LT. BLU
SWITCH
GRN / yEL
LT. BLU
P-1
IMPORTANT: PLEASE RETURN THIS SHEET TO IT’S MOL D MOUN TING WATER FILL
P-2

PLATE S WITCH
ORIGINAL LOCATION ICE MAKER