S-3 Proposed Filling Station (Caltex Station) : Conc. Gutter-Parapet Det

The document contains a diagram showing reinforcement details for a concrete structure. It includes the placement of temperature bars, bent-up bars, and extra cut bars spaced at various intervals within the concrete. The diagram also labels locations for the top of the firewall, parapet, roof deck slab, and different cross-sections of the structure.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
2K views1 page

S-3 Proposed Filling Station (Caltex Station) : Conc. Gutter-Parapet Det

The document contains a diagram showing reinforcement details for a concrete structure. It includes the placement of temperature bars, bent-up bars, and extra cut bars spaced at various intervals within the concrete. The diagram also labels locations for the top of the firewall, parapet, roof deck slab, and different cross-sections of the structure.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

1200 3300

10mmØ TEMPERATURE 12mmØ BENT-UP BARS SPACED 12mmØ EXTRA CUT BARS SPACED
BARS SPACED @ 300mm @ 200mm O.C., B.W. @ L/2 @ 200mm O.C., B.W. @ L/2 400 700 3150 150
O.C., B.W. @ L/4
C D E' E TOP OF FIREWALL
1000 9250mm 1000
100 120 L/4=700 L/2=1400 L/4=700

6" CHB
600 2500 4300 2450 500 400

1000
100

4" CHB
L/4=1025 L/2=2000 L/4=1025 L/4=488 L/2=975 L/4=488 TOP OF CHB PARAPET

450 350
4 TOP OF ROOF DECK SLAB W/ 1% SLOPE TO GUTTER

800
CB-3 RB-3 RB-3 RB-3 CB-3

120
200
GUTTER

RB-2

RB-2
10mmØ TEMPERATURE

400
L/4=700

L/4=975

120
CB-3 RB-2 1200

1300
10mmØ TEMPERATURE

RB-2
100 400 700

GUTTER
10mmØ TEMPERATURE
120 3"Ø STAINLESS STRAINER
12mmØ EXTRA CUT BARS
S-1 BOTTOM OF TOP OF CHB PARAPET
12mmØ RSB FROM SLAB

4" CHB
12mmØ BENT-UP BARS
12mmØ BENT-UP BARS

12mmØ BENT-UP BARS


12mmØ BENT-UP BARS
12mmØ EXTRA CUT BARS
CONC. PARAPET
L/2=1400

10mmØ RSB

350
12mmØ EXTRA CUT BARS

6" THK. CHB FIREWALL


FROM SLAB

RB-2
12mmØ EXTRA CUT BARS S-2 S-2
CS

L/2=1950

800
12mmØ EXTRA CUT BARS

120
GUTTER

130 120 200


4500mm

4300
RB-2

RB-2
12mmØ EXTRA CUT BARS

RB-2
S-2 CB-3 CB-3

450
12mmØ EXTRA CUT BARS

3150mm
COLUMN

COLUMN
10mmØ TEMPERATURE
L/4=700

50
3000
10mmØ TEMPERATURE
BOTTOM OF
CONC. PARAPET 3"Ø PVC DOWNSPOUT

GUTTER

2725

2700
10mmØ TEMPERATURE
10mmØ TEMPERATURE RB-2 RB-2 S-1 1/2"Ø HALF-ROUND
3 DRIP MOULD

L/4=975
10mmØ TEMPERATURE 12mmØ GUTTER-PARAPET REINFORCEMENT

10mmØ TEMPERATURE
10mmØ TEMPERATURE
12mmØ TEMPERATURE
12mmØ TEMPERATURE
12mmØ TEMPERATURE
12mmØ TEMPERATURE
10mmØ TEMPERATURE
S-1 S-1 S-1
CONCRETE GUTTER-PARAPET DETAIL
1200

CB-3

CB-3
CB-3

10mmØ TEMPERATURE

CONC. GUTTER-PARAPET DET.


12mmØ TEMP.
12mmØ TEMP.
GUTTER GUTTER GUTTER CB-3
RB-3
3' 5

200
12mmØ TEMP.
12mmØ TEMP.
S-3 SCALE 1 : 25 M
NOTE: REINFORCED CONCRETE SLAB MUST BE 120mm THK. w/ WATER-PROOFING.

3 REINFORCED CONCRETE SLAB LAYOUT CATWALK FIN. FLR. LINE GROUND FIN. FLR. LINE

200
175
S-3 SCALE 1 : 50 M DRIVEWAY LEVEL

C D E' E 4 GUTTER-ROOF SLAB DETAIL/SECTION


S-3 SCALE 1 : 30 M
9250mm 1000
1000 2500 4300 2450
600 1200 1200 1900 200 250 200 150 2-12mm Ø HORIZONTAL BARS
100 2-12mmØ HORI- 10mm Ø ZIGZAG TIES

150 mm
L/4=1175
TOP OF ZONTAL BARS
300mm 10mm Ø STIRRUPS 2-16mm Ø HORIZONTAL BARS 3-16mm Ø HORIZONTAL BARS 2-16mm Ø HORIZONTAL BARS

350 mm
6" THK. CHB FIREWALL 6" THK. CHB FIREWALL COMPACTED BEDDING DRIVEWAY 50 10mmØ TIES SPACED

400 mm

400 mm
4
4" THK. CONCRETE/CHB PARAPET

PARAPET

OR SUB-GRADE SPACED @: 6@50mm; 2-16mm Ø HORIZONTAL BARS 2-16mm Ø HORIZONTAL BARS @300mm O.C.
CB-3 RB-3 CB-3 8@100mm & REST@200mm LONGITUDINAL
1300

RB-2 RB-2 TOP OF DRIVEWAY 2-16mm Ø HORIZONTAL BARS PLANT BOX


2-16mm Ø HORIZONTAL BARS

50
GUTTER

2-16mm Ø HORIZONTAL BARS 2-16mm Ø HORIZONTAL BARS 100

200
150
STIFFENER SECTION @ SUPPORT
S-1
300
STIFFENER
RB-2

6-16mm Ø SECTION @ SUPPORT SECTION @ SUPPORT 2-12mm Ø HORIZONTAL BARS


4" THK. CONCRETE/CHB
3300

RB-2

150 mm
HORIZONTAL BARS 10mm Ø STIRRUPS SPACED @:
CS S-2 S-2 ROAD LEVEL 10mm Ø STIRRUPS SPACED @: 10mm Ø STIRRUPS SPACED @:
4500mm

200 250 200 10mm Ø ZIGZAG TIES


6@50mm; 8@100mm & REST@200mm
STIFFENER

CB-3
4300

STIFFENER 6@50mm; 8@100mm & REST@200mm 6@50mm; 8@100mm & REST@200mm


RB-2

RB-2

150
S-2 ON CENTER, BOTHWAYS ON CENTER, BOTHWAYS ON CENTER, BOTHWAYS

350
CROSS SECTION
3000

2-16mm Ø HORIZONTAL BARS


GUTTER

350 mm
GRADE BEAM 2-16mm Ø HORIZONTAL BARS 2-16mm Ø HORIZONTAL BARS
150mm THK. CHB, PLASTERED,

400 mm

400 mm
2-16mm Ø HORIZONTAL BARS
RB-2 RB-2
S-1 PLANT BOX GUTTER DETAIL STIFFENER BEAM WALL 2 PLAIN CEMENT SMOOTH FINISHED
3 8-16mm Ø VERTICAL
2-16mm Ø HORIZONTAL BARS 2-16mm Ø HORIZONTAL BARS 2-16mm Ø HORIZONTAL BARS 10mm Ø VERTICAL &
S-1 S-1 S-1
1200

CB-3

CB-3

CB-3

BARS 3-16mm Ø HORIZONTAL BARS 2-16mm Ø HORIZONTAL BARS HORIZONTAL REINFORCEMENT


CB-3
1800 (MINIMUM)

RB-3 SECTION @ MIDSPAN 100mm THK. CATWALK 1200 SPACED @ 600mm, O.C., B.W.
1200

GUTTER GUTTER GUTTER SECTION @ MIDSPAN SECTION @ MIDSPAN CATWALK


3'
200

10mm Ø LATERAL SLAB W/10mmØ BASEBARS


TIES SPACED AT: SPACED @ 600mm O.C., B.W. 100 1100 3-12mm Ø LONGITUDINAL
COLUMN
4" THK. CONCRETE/CHB PARAPET 4" THK. CONCRETE/CHB PARAPET 4@50mm; 6@100mm &
REST @ 150mm O.C.
FOOTING-TIE BEAM (FTB) ROOF BEAM 2 (RB-2) ROOF BEAM 3 (RB-3) WALL
STORAGE/
BARS W/ 10mmØ TIES
SPACED @ 300mm O.C., B.W.
DRIVEWAY
7-16mm Ø BASEBARS OFFICE FIN. FLR. LINE

ROOF DECK FRAMING PLAN

100100
FOOTING BOTHWAYS CATWALK FIN. FLR. LINE OFFICE FIN. FLR. LINE

200
2 10mm Ø STIRRUPS SPACED @:

25
6" THK. FIST-SIZED 5@50mm; 4@100mm & REST@150mm 500 700 250 100mm THK.

175
200
GRAVEL BEDDING ON CENTER, BOTHWAYS TOP OF DRIVEWAY GRAVEL BEDDING
S-3 SCALE 1 : 100 M
250 2-16mm Ø HORIZONTAL BARS 100mm THK. 300

200 200
300

FOOTING

400 mm
2-16mm Ø HORIZONTAL BARS GRAVEL BEDDING

RB-2
CATWALK GUTTER 500 mm

400
2-16mm Ø HORIZONTAL BARS 2-16mm Ø HORIZONTAL BARS
200

2-16mm Ø HORIZONTAL BARS 2-16mm Ø HORIZONTAL BARS CATWALK GUTTER & SLAB WALL2-FOOTING1 (W2-F1)
C D E' E TYPICAL SECTION
SECTION @ FREE END
CANTILEVER BEAM 3 (CB-3)
SECTION @ SUPPORT 150
200
100mm THK. SLAB 150
ON FILL W/ 10mmØ
1000 9250mm 1000 100mm THK. SLAB-ON-FILL W/10mmØ
1200mm 1200mm 1200mm 2-12mm Ø VERTICAL BARS 100

150
BASEBARS SPACED BASEBARS SPACED @ 600mm O.C., B.W.
@ 600mm O.C., B.W.
2500 4300 2450 450 300 450 450 300 450 450 300 450 2-12mm Ø VERTICAL BARS SALES AREA FIN. FLR. LINE
1200 1200 100 1800 C3: PLAN 10mm Ø VERTICAL &

200
WALL 1 HORIZONTAL REINFORCEMENT
TOP OF DRIVEWAY
W2-GB W2-FTB W2-FTB W2-FTB W2-GB SPACED @ 600mm, O.C., B.W.
4
300

300
4-12mm Ø VERTICAL BARS
8-16mm Ø VERTICAL 10mm Ø VERTICAL &
W1-F1
W1-F1

450

C3
C2-F3

C2-F3

C2-F3

C2-F3
1300

300
100mm THK. CHB, PLASTERED,
W1-FTB

BARS 10mm Ø LATERAL TIES SPACED @: HORIZONTAL REINFORCEMENT

800
+ 200 mm SPACED @ 600mm, O.C., B.W. PLAIN CEMENT SMOOTH FINISHED
4@50mm; 4@100mm & REST@200mm ROAD LEVEL
10mm Ø LATERAL 10mm Ø LATERAL ON CENTER, BOTHWAYS 3-12mm Ø LONGITUDINAL
W1-F1 10mm Ø LATERAL 150mm THK. CHB, PLASTERED,
3300

TIES SPACED AT: TIES SPACED AT: BARS W/ 10mmØ TIES


W2-FTB

CATWALK GUTTER

1200mm

1200mm

1200mm
W2-F1 TIES SPACED AT: WALL 2 PLAIN CEMENT SMOOTH FINISHED
4500mm

W1-F1 W1-F1 4@50mm; 6@100mm & 4@50mm; 6@100mm & SPACED @ 300mm O.C., B.W.
W2-FTB

W2-FTB

300
+ 175 mm

4300

+ 150 mm 4@50mm; 6@100mm & REST @ 150mm O.C. REST @ 150mm O.C. OFFICE FIN. FLR. LINE

350 mm

FTB
W1-F1

REST @ 150mm O.C.


W1-F1

100100
+ 150 mm
W1-F1

4-12mm Ø HORIZONTAL BARS


900

900

200
3000

300 mm
+ 200 mm + 100 mm 8-16mm Ø VERTICAL 8-16mm Ø VERTICAL
600 7-16mm Ø BASEBARS BARS BARS 10mm Ø STIRRUPS SPACED @:
100mm THK.
C3 BOTHWAYS GRAVEL BEDDING
6@50mm; 8@100mm & REST@200mm
3
450

W2-FTB W2-FTB 200 ON CENTER, BOTHWAYS 300


1200

7-16mm Ø BASEBARS 7-16mm Ø BASEBARS FOOTING


C2-F2 + 175 mmC2-F2 + 175 mm FTB BOTHWAYS BOTHWAYS C3 SECTION GRADE BEAM 200 SECTION 500 mm
3'
200

CATWALK GUTTER
2100 DRIVEWAY LEVEL: 0.0mm
C2-F2
RAMP UP
C2-F2 PLAN: C2-F2 PLAN: C2-F3 PLAN: C2-F4 C3 (STIFFENER COLUMN) WALL2 ON GRADE BEAM (W2-GB) WALL1-FOOTING1 (W1-F1)
(RAMP) (NOT REQUIRED FOR THIS PROJECT)
CALTEX OFFICE (32.98 sq.m.)

1 FOUNDATION PLAN 6 COLUMN/WALL-FOOTING & BEAM DETAILS


S-3 SCALE 1 : 100 M S-3 SCALE 1 : 25 M

PREPARED BY PRC No.: 82602 PROJECT APPROVED SHEET CONTENTS: MARK REVISION DATE FILE NAME : libmanan_nti_struc SHEET NO.

DRAWN BY :

PROPOSED FILLING STATION


PTR No.: 5326312 FOUNDATION PLAN
ROOF DECK FRAMING PLAN
S-3
DESIGNED BY :
ISSUED AT: PASACAO, C.S.
REINFORCED CONCRETE SLAB LAYOUT
CHARLES C. PALOMA ISSUED ON: JAN. , 2020 (CALTEX STATION) SOUTHERN CROSS DISTRIBUTION, Inc. GUTTER-ROOF SLAB DETAIL/SECTION
CONCRETE GUTTER-PARAPET DETAIL
DATE :

CHECKED :
28 MARCH 2020

CIVIL ENGINEER TIN: - LOCATION: LOT 5760, NAT'L. RD. (corner Road to Libmanan Proper), SAN ISIDRO, LIBMANAN, CAMARINES SUR O W N E R COLUMN/WALL-FOOTING & BEAM DETAILS DATE : STRUCTURAL