Brosur Access Control - Compressed
Brosur Access Control - Compressed
iCLASS SE®
Biometric &
Display Readers
hidglobal.com
SPECIFICATIONS
Language Support English, French, German, Spanish (International), Russian, Portuguese (Brazilian), Italian, Chinese (Simplified), Japanese, Korean
Transmit Frequency 13.56 MHz 13.56 MHz & 125 kHz
Communications Wiegand, Clock-and-Data, Open Supervised Device Protocol (OSPD) via RS485
Panel Connection Terminal Strip
UL294/cUL (US), FCC Certification (US), IC (Canada), CE (EU), RCM (Australia, New Zealand),
Certifications
SRRC (China), KCC (Korea), NCC (Taiwan), iDA (Singapore), RoHS, MIC (Japan)
1
Read range listed is statistical mean rounded to nearest whole centimeter. HID Global testing occurs in open air.
Some environmental conditions, including metallic mounting surface, can significantly degrade read range and
performance; plastic or ferrite spacers are recommended to improve performance on metallic mounting surfaces. 1
2
Standby AVG - RMS current draw without a card in the RF field.
3
Maximum AVG - RMS current draw during continuous card reads. Not evaluated by UL.
4
Peak - highest instantaneous current draw during RF communication.
hidglobal.com
North America: +1 512 776 9000
Toll Free: 1 800 237 7769 © 2017 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, HID Global, the HID Blue Brick logo, the Chain Design, iCLASS SE, iCLASS,
Europe, Middle East, Africa: +44 1440 714 850 iCLASS Seos, Secure Identity Object, bioCLASS and SIO are trademarks or registered trademarks of HID Global or its licensor(s)/supplier(s) in the US
and other countries and may not be used without permission. All other trademarks, service marks, and product or service names are trademarks or
Asia Pacific: +852 3160 9800 registered trademarks of their respective owners.
Latin America: +52 55 5081 1650 2017-07-13-iclass-se-bioled-ds-en PLT-03407
ACCESS flexibility.
iCLASS® smart readers and cards make access control more powerful, more versatile, and most
importantly, offer enhanced security through encryption and mutual authentication.
At the same time, iCLASS is user-friendly, delivering the convenience, affordability and reliability of
proximity technology, for which HID is known worldwide.
Using the 13.56 MHz technology platform, the iCLASS R10 read only contactless smart card reader
combines the longer read range of proximity with the power and heightened security of smart card
technology, making it ideal for access control applications.
Featuring crisp architectural styling, the reader has an elegantly curved faceplate. The high intensity,
three color light bar provides clear, visual feedback even in direct sunlight. Selectable, distinct tone
sequences indicate status conditions.
Be secure in knowing:
w iCLASS complies with the ISO 15693 standard for contactless smart card technology. Standards
are important in smart card technology because they make it possible for many equipment and
application developers to work with the smart card technology and create a broader range
of uses for the card.
w iCLASS technology can extend the use of your access control credential into other
applications today and tomorrow.
Features Specifications
Security 64-bit authentication keys are extremely secure. Readers and cards Typical Maximum Read Range*
require matching keys to function. All RF data transmission between 2” -3” (5.0-7.6 cm) with HID iCLASS Card
the card and reader is encrypted, using a secure algorithm. The 1” (2.5 cm) with HID iCLASS Key
key management system reduces the risk of compromised data or 1” (2.5 cm) with HID iCLASS Tag
duplicated cards. 1”-1.5” (2.5-3.8 cm) with HID iCLASS Prox
1”-2” (2.5 - 5.0 cm) with MIFARE (serial number only)
Programming/ Key management is made easy! All cards are shipped with unique
Configuration diversified keys, and readers are shipped with compatible keys.
*Using ISO 15693 mode (except MIFARE®or FeliCa). Dependent
All keys are derived from the HID Standard transport key. While
cards and readers with Standard keys are interchangeable, the keys upon installation conditions.
are highly secure, and cards can be made unique by ordering with
iCLASS® Elite formatting. Please note that all iCLASS credentials are available in either a 2k
bit (256 Byte), 16k bit (2k Byte) or 32k bit (4k Byte) configuration.
Cards and readers with site specific Custom keys are also optionally
available from the factory, or the iCLASS CP400 programmer can Dimensions
be used to create a site-specific key database and a reader 1.90” x 4.04” x .80” (4.83 cm x 10.26 cm x 2.03 cm)
configuration card, allowing the user to re-key cards and readers
on-site. The programmer also enables users to protect card data Material
with DES or triple DES encryption. Custom keys provide the highest UL94 Polycarbonate
level of security, where cards and readers are uniquely matched to
individual sites or customers, and are non-interchangeable. Power Supply
10 - 16 VDC reverse voltage protected
Easily Interfaced The reader’s Wiegand output easily interfaces with most existing
Linear supply recommended
Wiegand protocol access control panels. The reader reads standard
proximity format data from HID iCLASS cards and will output data
as encoded. Current Requirements (Avg/Peak)
80/300 mA @ 12 VDC
When reading MIFARE® cards, the reader can be configured to
output 26-bit, 32-bit, 34-bit or 40-bit Wiegand formats based on the Operating Temperature
card serial number. -31º to 150º F (-35º to 65º C)
Card Compatibility The iCLASS R10 reader is compatible with all iCLASS credentials. Operating Humidity
The reader’s versatility allows it to read credentials meeting several 5% to 95% relative humidity non-condensing
ISO standards:
Weight
• 15693 - read only; 2k bit (256 Byte), 16k bit (2k 3.2oz (90.7g)
Byte) and 32k bit (4k Byte) iCLASS credentials
• 14443A - read only; MIFARE (serial number) Transmit Frequency
Audio transducer provides various tone sequences to signify access 13.56 MHz
Audiovisual Indication
granted, access denied, power up and diagnostics. Visually impaired
cardholders can easily distinguish between access granted and Certifications
access denied. UL 294/cUL, FCC Certification, Canada Certification
CE Mark (Europe), New Zealand, Australia c-Tick
High-intensity light bar provides a clear visual status indication in IP55
red, green or amber, even in bright sunlight.
Pending Certifications
Mounting A three-part reader makes installation easier! Mounting plate Taiwan, Singapore, Germany VdS
attaches to mullion, door frame, U.S. single-gang J-box or any flat
surface. (Reader will not cover junction box.) Reader body snaps Cable Distance
onto mounting plate. Cover snaps over reader body, secured with a Wiegand Interface - 500 feet (150 m)
screw. Mount on metal with minimal read range impact. Recommended cable is ALPHA 1295 (22AWG)
5-conductor stranded with overall shield or equivalent. Additional
Indoor/ Rugged, weatherized polycarbonate enclosure, designed to conductors may be required to connect all outputs.
Outdoor Design withstand harsh environments, provides reliable performance and
resistance to vandalism.
© 2007 HID Global. All rights reserved. HID, the HID logo, and iCLASS are
trademarks or registered trademarks of HID Global in the U.S. and/or other
countries. All other trademarks, service marks, and product or service names are
trademarks or registered trademarks of their respective owners. Rev. 3/2007
For best results, please
MKT-R10_DS_EN
print on recycled paper.
The AIM-1SL has terminations for connection of one or The AIM-1SL also has terminations for the door contact
two Wiegand interface readers complete with 3 LED input, exit pushbutton, and one or two auxiliary (general
lines ( Red, Yellow, Green ) and a buzzer control line. The purpose) alarm inputs. These inputs are all Grade “A”
interface may be configured to use entry/exit readers for supervised for increased security. The supervision may be
anti-passback configurations or to use a single reader with disabled when not required via a dip-switch.
a push-button input for exit (REX). Each reader may also
be equipped with a keypad for use in a high security Card The AIM-1SL supports all major reader technologies
plus PIN mode or the user friendly Card or PIN mode including magnetic stripe, proximity, fingerprint, hand
(entry allowed without using a badge). geometry, barcode, long range infrared, and others. Many
of these reader types are available with integral keypads or
The AIM-1SL has a built-in 2 amp strike relay for direct the AP-410 may be connected with any of these to provide
control of the door locking device. The AIM-1SL also PIN capability.
provides an output for connection of up to 4 ADA-10/11,
external, high security, relay modules. The relays may be
added as required. The functions provided are high
security strike output, local alarm annunciation, and 2
general purpose programmable Aux outputs. The installer
has the choice of using the onboard strike relay or adding
the external ADA-10/11 relay for increased security.
3610 Birch Street
Newport Beach, California 92660-2619 USA
Phone 949-852-8178 • FAX 949-852-8172
http://www.apollo-security.com
E-mail: apollo@apollo-security.com
AIM1-SL provides the following features:
• Up to 8 MB Memory
• Full Ethernet Connectivity to host
and devices (with ENI-110/ANI-100)
For fast loading of configuration/cardholder data and reporting of events, the AAN-
100 can utilize RS-485, RS-232 or Ethernet communication with available 256-bit
AES Rijndael encryption and dual-path communication. Communication to de-
vices is routed through four ports that can support a versatile mix-and-match com-
bination of RS-485, RS-232 and Ethernet communication, all monitored by separate
communication status LED’s.
AAN-100
The AAN-100 features robust advanced electronics technology to ensure long life
with minimal failures making for ultimate security as well as lowering maintenance
costs. Surface mount manufacturing technology, field replaceable communica-
tions modules and remote flashable firmware for controllers and attached de-
vices take the worry out of your Access Control System. These outstanding advan-
tages combine to give Apollo equipment 1,100,500 hours (127 years!) mean time
between failures (MTBF).
Specifications:
Power Requirements: +12 to +28Vdc @ 300mA (with ASI-1) @ 400mA (with ANI)
Dimensions: 7.5 in x 5.5 in x 1.0 in (19 x 14 x 2.54 cm)
Environment: Operating Temperature: 0 to 70° C
Storage Temperature: -40 to 85° C
Relative Humidity: 0 to 95%, non-condensing
Weight: 1 Lb (.45 Kg)
Memory Backup: 3 AA Alkaline batteries type NEDA 15A
Communication: 2 Host Ports (RS-485 or Ethernet 100 BaseT w/ANI-100); 4 Device ports (RS-485, RS-232,
Specifications
Ethernet 100 BaseT w/ENI-110)
Inputs: 1 Cabinet Tamper; 1 Power Fault
Approvals: UL 294, UL 1076, CE, RoHS
APU-1210 460-110R 12V DC Power Supply & Enclosure for AAN-100 with 120V 8 Amp Switching Power Supply
and Battery (30aH)
ASM-48 430-132R Plug-in RS-485 Communications Driver
Rev 3.0, 1 MAR 2008 © Apollo Security Inc., Information contained in this document is subject to change without notice.
ENCLOSURE PANEL
Support for up to (1) additional PCIe SSD on Dell Precision Ultra-Speed drive (x8) with active cooling
Add-in cards
Thunderbolt™ 3 PCIe Card
Serial and Parallel Port PCIe Card (Full Height)
USB 3.2 Type CTM Gen 2 PCIe Card (Full Height)
Powered USB 3.2 PCIe Card
Smart Card Reader (CAC/PIV) with pre-boot authentication support
Bauar t gepruft
Sicherheit
egel ma ge
od o s
be wac g
www. tuv.com
ID 2000000000
■ Features ■ Applications
AC input range selectable by switch Industrial automation machinery
Withstand 300VAC surge input for 5 second Industrial control system
No load power consumption<0.5W Mechanical and electrical equipment
Miniature size and 1U low profile Electronic instruments, equipments or
High operating temperature up to 70℃ apparatus
Protections: Short circuit / Overload / Over voltage / Household appliances
Over temperature
Cooling by free air convection
Compliance to IEC/EN 60335-1(PD3) and
IEC/EN61558-1, 2-16 for household appliances
Operating altitude up to 5000 meters
Withstand 5G vibration test
High efficiency, long life and high reliability
LED indicator for power on
100% full load burn-in test
3 years warranty
■ Description
LRS-150 series is a 150W single-output enclosed type power supply with 30mm of low profile design.
Adopting the input of 115VAC or 230VAC(selectable by switch), the entire series provides an output voltage
line of 12V, 15V, 24V, 36V and 48V.
In addition to the high efficiency up to 90%, the design of metallic mesh case enhances the heat dissipation
of LRS-150 that the whole series operates from -30℃ through 70℃ under air convection without a fan.
Delivering an extremely low no load power consumption (less than 0.5W), it allows the end system to
easily meet the worldwide energy requirement. LRS-150 has the complete protection functions and 5G anti-
vibration capability; it is complied with the international safety regulations such as TUV EN60950-1,
EN60335-1,EN61558-1/-2-16, UL60950-1 and GB4943. LRS-150 series serves as a high price-to-
performance power supply solution for various industrial applications.
■ Model Encoding
LRS - 150 - 12
Output voltage
Output wattage
Series name
File Name:LRS-150-SPEC 2016-05-11
150W Single Output Switching Power Supply LRS-150 series
SPECIFICATION
MODEL LRS-150-12 LRS-150-15 LRS-150-24 LRS-150-36 LRS-150-48
DC VOLTAGE 12V 15V 24V 36V 48V
RATED CURRENT 12.5A 10A 6.5A 4.3A 3.3A
CURRENT RANGE 0 ~ 12.5A 0 ~ 10A 0 ~ 6.5A 0 ~ 4.3A 0 ~ 3.3A
RATED POWER 150W 150W 156W 154.8W 158.4W
RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 200mVp-p 200mVp-p 200mVp-p
OUTPUT VOLTAGE ADJ. RANGE 10.2 ~ 13.8V 13.5 ~ 18V 21.6 ~ 28.8V 32.4 ~ 39.6V 43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3 ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION Note.4 ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION Note.5 ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
SETUP, RISE TIME 500ms, 30ms/230VAC 500ms,30ms/115VAC at full load
HOLD UP TIME (Typ.) 40ms/230VAC 35ms/115VAC at full load
VOLTAGE RANGE 85 ~ 132VAC / 170 ~ 264VAC by switch 240 ~ 370VDC(switch on 230VAC)
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 87.5% 88.5% 89% 89% 90%
INPUT
AC CURRENT (Typ.) 2.8A/115VAC 1.6A/230VAC
INRUSH CURRENT (Typ.) COLD STAR 60A/230VAC
LEAKAGE CURRENT <0.75mA / 240VAC
110 ~ 140% rated output power
OVER LOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
PROTECTION 13.8 ~ 16.2V 18.75 ~ 21.75V 28.8 ~ 33.6V 41.4 ~ 48.6V 55.2 ~ 64.8V
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE Shut down o/p voltage, re-power on to recover
WORKING TEMP. -30 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY 20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS UL60950-1, TUV EN60950-1, EN60335-1, EN61558-1 /- 2 - 16 ,CCC GB4943 approved
iCLASS® Card
CONTACTLESS SMART CARD
PVC CARDS 2000, 2001, 2002, 2003, 2004
COMPOSITE PVC/PET CARDS 2100, 2101, 2102, 2103, 2104
access control, biometrics, cashless vending, access control more powerful, more versatile,
public transportation, airline ticketing and more secure. All radio frequency data
FEATURES: and customer loyalty programs. Multiple, transmission between the card and reader is
13.56 MHz read/write contactless smart securely separated files enable numerous encrypted using a secure algorithm. By using
card technology provides high-speed, applications and support future growth. industry standard encryption techniques,
reliable communications iCLASS reduces the risk of compromised data
with high data integrity.
The iCLASS Card offers iCLASS 13.56 MHz or duplicated cards. For even higher security,
iCLASS technology ensures high security
with mutual authentication, encrypted contactless read/write smart card technology the card data may also be protected with DES
data transfer, and 64-bit diversified keys along the ability to add a magnetic stripe, or triple DES encryption. Multiple securely
for read/write capabilities.
barcode, and anti-counterfeiting features separated application areas are each protected
Any existing HID format can be factory
including custom artwork or a photo by 64-bit diversified read/write keys which
or field programmed into the secure HID
access control application area. identification directly on the credential. allow complex applications and provide for
Available in 2k bit (256 Byte), 16k bit (2K Your iCLASS Card can now be utilized for future expansion.
Byte) or 32k bit (4K Byte) configurations. such diverse applications including access
Meets ISO standards for thickness for control, network log-on security, automotive Security mechanisms such as mutual
use with all direct image and thermal authentication and encryption are efficiently
transfer printers vehicle identification, cashless vending, time
and attendance, and biometric verification. combined with fast processing and data
Add a magnetic stripe, barcode, anti-
counterfeiting, or photo ID. Multiple securely separated files enable communication, resulting in transaction times
numerous applications and can support future of less than 100 milliseconds for a typical
capabilities. The iCLASS Card meets strict ISO secure e-purse transaction.
hidglobal.com
ALL 2K BIT (256 BYTE) ICLASS CREDENTIALS HAVE THE ALL 16K BIT (2K BYTE) AND 32K BIT (4K BYTE) ICLASS
FOLLOWING FEATURES: CREDENTIALS HAVE THE FOLLOWING FEATURES:
Available in two application area configuration only. Sufficient read/write memory to store multiple biometric
Provides the HID standard access control application area templates.
and one other application area for user 16k available in a two or sixteen application area configuration.
customization. 32k available with 16k memory configured in either 2 or 16
Meets ISO 15693 standard for contactless communications. application areas, plus an additional 16k user configurable memory.
Provides a cost effective way to improve the security of your Multiple securely separated files enable numerous applications,
access control installation. including the HID standard access control application, and support
future growth.
Meets ISO 15693 and 14443B for contactless communications.
SPECIFICATIONS
Operating
-40° to 158° F (-40° to 70° C)
Temperature
Print directly to the card with a direct image or thermal transfer printer. Slot
Card Marking
An ASSA ABLOY Group brand punch vertically for easy use. *
© 2011 HID Global Corporation. All rights reserved. HID, Custom Graphics
the HID logo and Secure Identity Object are trademarks
Optional
or registered trademarks of HID Global in the U.S. and/or
other countries. All other trademarks, service marks, and Operates With iCLASS® readers
product or service names are trademarks or registered
trademarks of their respective owners.
2012-02-09-iclass-card-ds-en Warranty Lifetime warranty. See complete warranty policy for details.
* When customizing cards using Re-Transfer Printers that fuse images to the surface of the card by
applying heat and pressure (such as the FARGO HDP5000) we recommend the use of composite cards,
which are better able to withstand the higher application temperatures.
hidglobal . c om
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
1-800-Belden1
General Description:
22 AWG stranded (7x30) tinned copper conductors, polypropylene insulation, twisted pairs, individually
Beldfoil® shielded (100% coverage), 24 AWG stranded tinned copper drain wire, PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
2 22 7x30 TC - Tinned Copper
Insulation
Insulation Material:
Insulation Material Wall Thickness (in.)
PP - Polypropylene 0.009
Inner Shield
Inner Shield Material:
Inner Shield Trade Name Type Inner Shield Material Coverage (%)
Beldfoil® (Z-Fold®) Tape Aluminum Foil-Polyester Tape 100
Outer Shield
Outer Shield Material:
Outer Shield Material
Unshielded
Outer Jacket
Outer Jacket Material:
Outer Jacket Material Nom. Wall Thickness (in.)
PVC - Polyvinyl Chloride 0.020
Overall Cable
Overall Nominal Diameter: 0.160 in.
Pair
Pair Color Code Chart:
Number Color
1 Red & Black
2 Green & White
Page 1 of 3 04-30-2013
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
CEC/C(UL) Specification: CM
EU CE Mark: Yes
Flame Test
UL Flame Test: UL1685 UL Loading
Plenum/Non-Plenum
Plenum (Y/N): No
Nom. Inductance:
Inductance (µH/ft)
0.17
Page 2 of 3 04-30-2013
Detailed Specifications & Technical Data
ENGLISH MEASUREMENT VERSION
Notes:
C = CRATE REEL PUT-UP.
Y = FINAL PUT-UP LENGTH MAY VARY -10% TO +20% FROM LENGTH SHOWN.MAY CONTAIN 2 PIECES. MINIMUM LENGTH OF ANY ONE PIECE IS 1500'.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3 04-30-2013