All manuals and user guides at all-guides.
com
        SHDSL.bis
   Up to 60Mbps
 Ddd
  E1 / Nx64 /Ethernet
FlexDSL Orion3
                                              Features
                                                 •    Up to 15Mbps Data Transmission per Copper Pair
                                                 •    SHDSL and SHDSL.bis, TC-PAM16/32
                                                                    m
                                                 •    Additional TC-PAM4/8/64/128 Available
                                                 •    1, 2 or 4 Copper Pairs Support
                                                 •    2 or 4 Port Ethernet Switch (10/100BaseT)
                                                 •    SFP connector for mixed Copper and Fiber applications
                                                 •    QoS, VLAN and RSTP Support
                                                 •    E1 (G.703/704, Balanced/Unbalanced)
                                                     .co
                                                 •    Nx64 (V.35, V.36, X.21, V.28) and RS-232/485
                                                 •    Multi-Service Operation
                                                 •    Point-to-Point and Point-to-Multipoint Operation
                                                 •    Console Port, Telnet, Web, SNMP Management
                                                 •    24/48VDC Powered, Low Power Consumption
                                                 •    Included Primary Protection
                                                 •    Robust DIN-Rail Metal Enclosure
                                                 •    Industrial Temperature Range Available
                                       es
The FlexDSL Orion3 product family offers a broad range of products, which are based on the latest SHDSL.bis standards
(ITU-T G.991.2 & ETS TS 101 524) The FlexDSL Orion3 supports TC-PAM16/32 and the new TC-PAM4/8/64/128 line coding.
The FlexDSL Orion3 allows symmetrical data and voice transmission at speeds up to 15.2Mbps over a single pair of copper.
In addition, the FlexDSL Orion3 supports DSL channel bonding for up to 4 copper pairs in order to achieve speeds to
60.8Mbps. The SFP module (available on selected models) allows Ethernet data transmission over mixed Copper and Fiber
                          uid
media.
FlexDSL Orion3 SHDSL.bis Extended modems can provide up to 2 E1 interfaces, which support framed and unframed
services (G.703/G.704). An integrated 2 or 4 port Ethernet layer 2 managed Switch with VLAN support (10/100BaseT)
ensures connectivity to IP services. Beside of E1 and Ethernet the additional Nx64 interfaces can be configured as V.35, V.36,
X.21, V.28, or RS232/RS485 interface (cable selectable).
Like all FlexDSL Orion products, the Orion3 SHDSL.bis modems family is based on industrial components, have extended
temperature range, advanced surge protection and produced in Switzerland.
            -g
Possible Applications
                                 a)
all
                                                                                         c)
                                 b)
                                                                                       d)
                                                         a) Ethernet Transmission Point-to-Point
                                                         b) Ethernet Transmission Point-to-Multipoint
                                                         c) Ethernet Add/Drop over a Long Copper Line
                                                         d) Ethernet Transmission over Copper and Fiber
 FlexDSL Telecommunications AG                                                                               Tel: +41 44 741 52 90
 Steinackerstrassse 31                                                                                       Fax: +41 44 741 52 93
 8902 Urdorf                                                                                                 Email: info@flexdsl.ch
 Switzerland                                                 Page 1/9                                         Web: www.flexdsl.ch
                                       All manuals and user guides at all-guides.com
Quick Installation Guide
Enter an Orion3 Device
You can use the Monitor (Local Craft Terminal, RS-232) interface with Hyper Terminal (or any equal program) or you can
address the device with Telnet through the Ethernet interface.
Monitor (LCT, RS-232 or USB) Interface:
       Configure the COM port: Bits per second:9600, Data bits: 8, Parity: None, Stop bits: 1, Flow control: None
       Press <ENTER>.
Telnet through Ethernet Interface:
       Type in command line <Telnet 192.168.0.235> and press <ENTER>. This is the default Ethernet Address for Orion3
        devices.
After a successful entering the main menu of the device will be displayed.
Configure an Orion3 Device
A first installation example with the most important commands and points to care about is shown below. We just like to have
an Ethernet transmission between the two devices over 2 SHDSL copper pairs with a speed of 11.4Mbit/s. The pairs should
aggregate (bundle) the data traffic and in case of any SHDSL pair failure, the remaining pairs should continue to work.
                                 Computer                 Device 1                    Device 2
Enter in device 1 with the Monitor (LCT, RS-232 or USB) or Telnet interface.
Type following commands                         Description
3 <>                                           Go to Configuration Management (CM)
<DEFAULT EVERYTHING> <>                        Set everything to default configuration
<MASTER ON 1> <>                               Configure SHDSL 1 as MASTER
<MASTER ON 2> <>                               Configure SHDSL 2 as MASTER
<PAYLOAD WAN 1> <>                             Configure Ethernet over SHDSL 1
<PAYLOAD WAN 2> <>                             Configure Ethernet over SHDSL 2
<NET> <>                                       Go to NET menu
<SETIP 10.0.2.200> <>                          Set the IP-address of the device
<NETMASK 255.0.0.0> <>                         Set the subnet mask
<GATEWAY 10.0.0.101> <>                        Set the default gateway
<M> <>                                         Go to Configuration Management (CM)
<M> <>                                         Go to Main Menu
2 <>                                           Go to Fault and maintenance management (FMM)
<APPLY ALL> <>                                 Apply all configurations (written in the running config.)
<CONFIRM> <>                                   Confirm all configurations (written in the startup config.)
In Menu Configuration Management (CM) you can type <CONFIG> to see the following picture:
CO_CM>CONFIG
--------------------------------------------------------------------------------
Running Line Configuration
--------------------------------------------------------------------------------
xDSL               DSL1          DSL2
  Mode          : Master(HTU-C) Master(HTU-C)
  Extended rates: OFF            OFF
  Line coding   : PAM32          PAM32
  Baserate      : 89             89
  Annex         : B              B
  Payload       : WAN            WAN
  Clock source : Int             Int
  GS compatible : OFF
  NM threshold : OFF
  LA threshold : OFF
--------------------------------------------------------------------------------
CO_CM>
 FlexDSL Telecommunications AG                                                                                Tel: +41 44 741 52 90
 Steinackerstrassse 31                                                                                        Fax: +41 44 741 52 93
 8902 Urdorf                                                                                                  Email: info@flexdsl.ch
 Switzerland                                                   Page 2/9                                        Web: www.flexdsl.ch
                                      All manuals and user guides at all-guides.com
Enter in device 2 with the Monitor (LCT, RS-232 or USB) or Telnet interface.
Type following commands                        Description
3 <>                                          Go to Configuration Management (CM)
<DEFAULT EVERYTHING> <>                       Set everything to default configuration
<MASTER OFF 1> <>                             Configure SHDSL 1 as SLAVE
<MASTER OFF 2> <>                             Configure SHDSL 2 as SLAVE
<PAYLOAD WAN 1> <>                            Configure Ethernet over SHDSL 1
<PAYLOAD WAN 2> <>                            Configure Ethernet over SHDSL 2
<NET> <>                                      Go to NET menu
<SETIP 10.0.2.201> <>                         Set the IP-address of the device
<NETMASK 255.0.0.0> <>                        Set the subnet mask
<GATEWAY 10.0.0.101> <>                       Set the default gateway
<M> <>                                        Go to Configuration Management (CM)
<M> <>                                        Go to Main Menu
2 <>                                          Go to Fault and maintenance management (FMM)
<APPLY ALL> <>                                Apply all configurations (written in the running config.)
<CONFIRM> <>                                  Confirm all configurations (written in the startup config.)
In Menu Configuration Management (CM) you can type <CONFIG> to see the following picture:
CP_CM>CONFIG
--------------------------------------------------------------------------------
Running Line Configuration
--------------------------------------------------------------------------------
xDSL               DSL1          DSL2
  Mode          : Slave(HTU-R) Slave(HTU-R)
  Extended rates: OFF            OFF
  Line coding   : PAM32          PAM32
  Baserate      : 89             89
  Annex         : B              B
  Payload       : WAN            WAN
  Clock source : Int             Int
  GS compatible : OFF
  NM threshold : OFF
  LA threshold : OFF
--------------------------------------------------------------------------------
CP_CM>
The idea is the following: the default settings help any device to be in an initial state, then the MASTER/SLAVE mode is
enabled on the modem, then the transmit data is configured, then the network settings are configured (IP address, default
subnet mask and default gateway) and finally, these settings are applied and then are written in the EEPROM.
                           ATTENTION
                           DON’T FORGET TO WRITE THE CONFIGURATION IN THE STARTUP CONFIGURATION WITH
                           THE FOLLOWING COMMANDS:
                            2 <>              Go to Fault and maintenance management (FMM)
                            <APPLY ALL> <>    Apply all configurations (written in the running config.)
                            <CONFIRM> <>      Confirm all configurations (written in the startup config.)
 FlexDSL Telecommunications AG                                                                               Tel: +41 44 741 52 90
 Steinackerstrassse 31                                                                                       Fax: +41 44 741 52 93
 8902 Urdorf                                                                                                 Email: info@flexdsl.ch
 Switzerland                                                  Page 3/9                                        Web: www.flexdsl.ch
                                            All manuals and user guides at all-guides.com
Connector Description
SHDSL Technical Specification                                                        SHDSL Connector Specification
Specification                     ITU-T G.991.2 G.shdsl and G.shdsl.bis                           Pin No   Description
Line Code                         TC-PAM16/32, Extended: TC-PAM4/8/64/128                            1     NC (not used)
Impedance                         135                                                               2     NC (not used)
Transmit Power                    13.5 (Annex A) or 14.5 (Annex B) dBm @ 135                       3       SHDSL interface B *
Number of Pairs                   2 or 4                                                            4       SHDSL interface A
Bit Rate                          192 to 5704kbit/s, Extended: 128 to 15232kbit/s                   5       SHDSL interface A
Overvoltage Protection            ITU-T Rec. K.20/K.21                                              6       SHDSL interface B *
Connector Type                    RJ-45 Female, 8 pin                                               7       NC (not used)
                                                                                                    8       NC (not used)
                                                                                                 * only used in V84
Specification                     ITU-T G.991.2 G.shdsl and G.shdsl.bis                              1      SHDSL interface B (2)
Line Code                         TC-PAM16/32, Extended: TC-PAM4/8/64/128                            2      SHDSL interface B (2)
Impedance                         135                                                               3      SHDSL interface D (4)
Transmit Power                    13.5 (Annex A) or 14.5 (Annex B) dBm @ 135                       4       SHDSL interface D (4)
Number of Pairs                   4                                                                 5       SHDSL interface A (1)
Bit Rate                          192 to 5704kbit/s, Extended: 128 to 15232kbit/s                   6       SHDSL interface A (1)
Overvoltage Protection            ITU-T Rec. K.20/K.21                                              7       SHDSL interface C (2)
Connector Type                    Phoenix Mini Combicom MCD 1,5/4-G1F-3,81                          8       SHDSL interface C (2)
                                  Female, 8 pin                                                  only used in V84I, V84IS
Matching Type for Cable           FK-MCP 1,5/ 4-STF-3,81
                                  For AWG 16-28
                                  Area 0.14–1.5 mm2 or Diameter 0.42-1.4 mm
Ethernet Technical Specification                                                     Ethernet Connector Specification
Standard:                         IEEE-802.3, VLAN/QoS IEEE-802.1q/p                              Pin No   Description
Number of Interfaces              2/4                                                                1     Tx+ (transmit data)
Data Rate                         10/100BaseT, Full/Half Duplex                                      2     Tx- (transmit data)
Protocols                         Data, Telnet, SNMP, WEB                                            3     Rx+ (receive data)
Signal Level                      Ethernet                                                           4     NC (not used)
MDI/MDI-X auto crossover          Supported                                                          5     NC (not used)
Auto Negotiation                  Supported                                                          6     Rx- (receive data)
Connector Type                    RJ45 Female, 8 pin,                                                7     NC (not used)
                                                                                                     8     NC (not used)
100Base-FX Ethernet (V84S, V84IS)                                                    SFP Connector
Standard:                         IEEE-802.3, VLAN/QoS IEEE-802.1q/p
Data Rate              100BaseT, Full/Half Duplex
Signal Level           Ethernet
Connector Type         Type –SFP Tyco 1658391-1, only V84S
                       Type –SFP Amphenol UE78-B1126 only V84IS
Recommended 155Mbps SFP Transceiver (Fast Ethernet, OC-3, STM-1):
                       LS38-A3S-TC-N
                       XGSF-03-1503-80
E1 (G.703) Technical Specification                                                   E1 (G.703) Connector Specification
Specification                     ETS 300 166, ITU-T Rec. G.703, G.704                            Pin No   Description
Number of Interfaces              2                                                                  1     E1 Input → CH1/2 Wire A
Line Code                         HDB3                                                               2     E1 Input → CH1/2 Wire B
Impedance                         either 120 or 75                                                 3     NC (not used)
Jitter                            ITU-T Rec. G.823, ETSI TS 101 135                                  4     E1 Output → CH1/2 Wire A
Bit Rate                          2048kbit/s ± 50 ppm                                                5     E1 Output → CH1/2 Wire B
ESD Protection                    8kV (Air discharge)                                                6     NC (not used)
Connector Type                    RJ45 Female, 8 pin                                                 7     NC (not used)
                                                                                                     8     NC (not used)
  FlexDSL Telecommunications AG                                                                                      Tel: +41 44 741 52 90
  Steinackerstrassse 31                                                                                              Fax: +41 44 741 52 93
  8902 Urdorf                                                                                                        Email: info@flexdsl.ch
  Switzerland                                                             Page 4/9                                    Web: www.flexdsl.ch
                                           All manuals and user guides at all-guides.com
Nx64 Interface                                                                     DB-26H Connector Specification
Specification                     V.35/V.36/X.21/V.28                                          Pin No   V.35/36/28       X.21
Data Rate                         1..128x64kbps (synchronous) for V.35/V.36/X.21                 1      Mode Sel 2
                                  1..3x64kbps (synchronous) for V.28                             2      Mode Sel 1
Connector Type                    DB26 high density female                                       3      Mode Sel 0
Cable Connector Type              V.35 ISO2593 (34 Pin MRAC)                                     4      DTE/DCE
                                  V.36 ISO4902 (37 Pin Dsub)                                     5      LLoopback
                                  X.21 ISO4903 (15 Pin Dsub)                                     6      TXD(A)      Ta
ESD Protection                    8kV (Air discharge)                                            14     TXD(B)      Tb
                                                                                                 19     RXD(A)      Ra
                                                                                                 10     RXD(B)      Rb
                                                                                                 24     RTS(A)      Ca
                                                                                                 15     RTS(B)      Cb
                                                                                                 26     CTS(A)      Ia
                                                                                                 17     CTS(B)      Ib
                                                                                                 18     DSR(A)
                                                                                                 9      DSR(B)
                                                                                                 16     DTR(A)
                                                                                                 25     DTR(B)
                                                                                                 8      DCD(A)
                                                                                                 7      DCD(B)
                                                                                                 22     TTC(A)      Xa
                                                                                                 13     TTC(B)      Xb
                                                                                                 21     TXC(A)
                                                                                                 12     TXC(B)
                                                                                                 20     RXC(A)      Sa
                                                                                                 11     RXC(B)      Sb
                                                                                                 23     SGND (Ground)
4x RS-232(V24) Interface                                                           DB-26H Connector Specification
Specification                     RS-232/485                                                   Pin No   4x RS-232
Data Rate                         1200..256000 bps (asynchronous)                                1      TXD-1
Format RS-232/RS-485              Bits: 5… 8                                                     2      RTS-1
                                  Stop bits: 1/1.5/2                                             3      TXD-2
                                  Parity: odd/even/odd/mark/space                                4      RTS-2
Connector Type                    DB26 high density female                                       6      RXD-1
ESD Protection                    8kV (Air discharge)                                            7      CTS-1
                                                                                                 8      RXD-2
                                                                                                 9      CTS-2
                                                                                                 11     PGND (Protection Ground)
                                                                                                 12     PGND (Protection Ground)
                                                                                                 13     PGND (Protection Ground)
                                                                                                 14     SGND (Ground)
                                                                                                 15     CC (Cable Connected)
                                                                                                 19     TXD-3
                                                                                                 20     RTS-3
                                                                                                 21     TXD-4
                                                                                                 22     RTS-4
                                                                                                 23     RXD-3
                                                                                                 24     CTS-3
                                                                                                 25     RXD-4
                                                                                                 26     CTS-4
                                                                                                 27     PGND (Protection Ground)
                                                                                                 28     PGND (Protection Ground)
  FlexDSL Telecommunications AG                                                                                     Tel: +41 44 741 52 90
  Steinackerstrassse 31                                                                                             Fax: +41 44 741 52 93
  8902 Urdorf                                                                                                       Email: info@flexdsl.ch
  Switzerland                                                          Page 5/9                                      Web: www.flexdsl.ch
                                             All manuals and user guides at all-guides.com
RS-232(V24)/RS-485 Interface                                                            DB-26H Connector Specification
Specification                     RS-232/485                                                        Pin No    RS-232          RS-485
Data Rate                         1200..256000 bps (asynchronous)                                     1       DTR
Format RS-232/RS-485              Bits: 5… 8                                                          2       DSR
                                  Stop bits: 1/1.5/2                                                  3       CTS
                                  Parity: odd/even/odd/mark/space                                     6       DCD
Connector Type                    DB26 high density female                                            7       RXD           TXD+
Cable Connector Type              RS-232 EIA/TIA-574                                                  8       RTS
                                  ISO2110 (9 Pin or 25 Pin Dsub)                                      9       TXD           RXD+
ESD Protection                    8kV (Air discharge)                                                 11      PGND (Protection Ground)
                                                                                                      12      PGND (Protection Ground)
                                                                                                      13      PGND (Protection Ground)
                                                                                    m
                                                                                                      14      SGND (Ground)
                                                                                                      15      CC (Cable Connected)
                                                                                                      16                    TXD-
                                                                                                      18                    RXD-
                                                                .co
Monitor/Local Craft Terminal Technical Specification                                    Monitor/LCT Connector Specification
Specification                     EIA-232 / V.28                                                    Pin No    Description
Data Rate                         9600 baud, asynchronous                                              1      Urgent Alarm Output
Protocol                          8 bit, no parity, 1 stop bit , no flowcontrol                        2      TXD (Transmit Data)
                                  no linefeed with carriage return                                     3      RXD (Receive Data)
Signal Level                      V.28                                                                 4      NC (not used)
Alarm Output Spec                 Load Driver                                                          5      SGND (Ground)
                                                es
Max. Switching Voltage            60VDC                                                                6      NC (not used)
Max. Switching Current            150mA                                                                7      NC (not used)
Connector Type                    DB9 Female                                                           8      NC (not used)
                                                                                                       9      Not Urgent Alarm Output
Monitor/Local Craft Terminal Technical Specification                                    Monitor/LCT Connector Specification
                           uid
Specification                     USB V2.0 full and low speed                                       Pin No    Description
Data Rate                         12Mbit/s                                                             1      +5V
Protocol                          Master/Slave, Uses the USB communication                             2      Data +
                                  device class (CDC) drivers to take advantage of                      3      Data -
                                  the installed PC RS-232 software to talk over the                    4      SGND
                                  USB
Connector Type                    USB Type B Female connector
             -g
Power Supply Technical Specification                                                    Power Supply Connector Specification
Specification                     ETSI ETS 300 132-2                                                Pin No    Description
Voltage                           38-230VDC local power, remote power                                   1       Negative power terminal 1
Voltage (-24V models)             18-230VDC local power, no remote power                                2       Protection ground
Voltage (V84S3 model)             18-300VDC local power, no remote power                                3       Negative power terminal 2
all
Power Consumption                 Typically 4/6 Watts if 2/4 DSL pairs                                  4       Positive power terminal
Connector Type                    Molex Mini-Fit 39-01-2040                                         All units except V84I, V84IS
Specification                     ETSI ETS 300 132-2                                                   1       Negative power terminal 1
Voltage (-24V models)             18-230VDC local power, no remote power                               2       Protection ground
Power Consumption                 Typically 6 Watts if 4 DSL pairs                                     3       Positive power terminal
Connector Type                    Phoenix Mini Combicom MC 1,5/3-GF-3,5                             only used in V84I, V84IS
                                  Female, 3 pin
Matching Type for Cable           FK-MCP 1,5/ 3-STF-3,5
                                  For AWG 16-28
                                  Area 0.14–1.5 mm2 or Diameter 0.42-1.4 mm
  FlexDSL Telecommunications AG                                                                                          Tel: +41 44 741 52 90
  Steinackerstrassse 31                                                                                                  Fax: +41 44 741 52 93
  8902 Urdorf                                                                                                            Email: info@flexdsl.ch
  Switzerland                                                                Page 6/9                                     Web: www.flexdsl.ch
                                       All manuals and user guides at all-guides.com
Panel Description
 Connector                             LED     RED               GREEN                  AMBER                  OFF
  xDSL 1 (DSL No 1)                    Left    DSL not working   DSL normal operation
  xDSL 1 (DSL No 3, only V84)          Right   DSL not working   DSL normal operation
  xDSL 2 (DSL No 2)                    Left    DSL not working   DSL normal operation
  xDSL 2 (DSL No 4, only V84)          Right   DSL not working   DSL normal operation
  G.703 1 or G.703 2 (NI 3 V81)        Left                      E1 normal operation                           Failure / no E1 Signal
  G.703 1 or G.703 2 (NI 3 V81)        Right                                            E1 Alarm               E1 normal operation
  Ethernet (NI 1/2 V83, 1..4 on V84)   Left                      Blinking = Data                               Connection not active
  Ethernet (NI 1/2 V83, 1..4 on V84)   Right                                            100 Mbit/s data rate   10 Mbit/s data rate
* NI means NETWORK INTERFACE
Panel Description V84S (Version with SFP interface)
 Connector                             LED     RED               GREEN                  AMBER                  OFF
 xDSL 1 (DSL No 1)                     Left    DSL not working   DSL normal operation
 xDSL 1 (DSL No 3)                     Right   DSL not working   DSL normal operation
 xDSL 2 (DSL No 2)                     Left    DSL not working   DSL normal operation
 xDSL 2 (DSL No 4)                     Right   DSL not working   DSL normal operation
 Ethernet (NI 1/2)                     Left                      Blinking = Data                               Connection not active
 Ethernet (NI 1/2)                     Right                                            100 Mbit/s data rate   10 Mbit/s data rate
 SFP                                   n/a
Panel Description V84I (Special Industrial Version)
 Connector                             LED     RED               GREEN                  AMBER                  OFF
 xDSL 1 (DSL No 1)                       1     DSL not working   DSL normal operation
 xDSL 1 (DSL No 3)                       3     DSL not working   DSL normal operation
 xDSL 2 (DSL No 2)                       2     DSL not working   DSL normal operation
 xDSL 2 (DSL No 4)                       4     DSL not working   DSL normal operation
 Ethernet (1..4)                       Left                      Blinking = Data                               Connection not active
 Ethernet (1..4)                       Right                                            100 Mbit/s data rate   10 Mbit/s data rate
 FlexDSL Telecommunications AG                                                                                       Tel: +41 44 741 52 90
 Steinackerstrassse 31                                                                                               Fax: +41 44 741 52 93
 8902 Urdorf                                                                                                         Email: info@flexdsl.ch
 Switzerland                                                     Page 7/9                                             Web: www.flexdsl.ch
                                        All manuals and user guides at all-guides.com
Panel Description V84IS (Special Industrial Version with SFP interfaces)
 Connector                              LED     RED                GREEN                   AMBER                  OFF
 xDSL 1 (DSL No 1)                        1     DSL not working    DSL normal operation
 xDSL 1 (DSL No 3)                        3     DSL not working    DSL normal operation
 xDSL 2 (DSL No 2)                        2     DSL not working    DSL normal operation
 xDSL 2 (DSL No 4)                        4     DSL not working    DSL normal operation
 Ethernet (1/2)                         Left                       Blinking = Data                                Connection not active
 Ethernet (1/2)                         Right                                              100 Mbit/s data rate   10 Mbit/s data rate
 SFP 1                                    1                        Blinking = Data                                Connection not active
 SFP 1                                    3                                                100 Mbit/s data rate
 SFP 2                                    2                        Blinking = Data                                Connection not active
 SFP 2                                    4                                                100 Mbit/s data rate
Panel Description (Version with Serial Interface)
 Connector                              LED     RED                GREEN                   AMBER                  OFF
 xDSL 1 (DSL No 1)                        1     DSL not working    DSL normal operation
 xDSL 1 (DSL No 3)                       n/a
 xDSL 2 (DSL No 2)                        2     DSL not working    DSL normal operation
 xDSL 2 (DSL No 4)                       n/a
 Ethernet (1..2)                        Left                       Blinking = Data                                Connection not active
 Ethernet (1..2)                        Right                                              100 Mbit/s data rate   10 Mbit/s data rate
 Serial (3)                             n/a
Environment, EMC and Safety
Storage:                         ETS 300 019-1-1 Class 1.2       (-40C … +70C) Extended Temperature
Transportation:                  ETS 300 019-1-2 Class 2.3       (-40C … +70C)
Operation:                       ETS 300 019-1-3 Class 3.2       (-25C … +70C) Extended Temperature
                                 When inside outdoor rack:
                                 ETS 300 019-1-3 Class 3.3/3.4 partly over -25°C … +80°C
Dimension:                       216(W)x165(D)x43(H) mm
Weight                           < 1.0kg in Metal DIN-Rail Enclosure
Standards:                       EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013
                                 EN 300 386 V1.6.1:2012          EN 61000-4-3:2006/A1:2008/A2:2010
                                 EN 50121-4:2006/AC:2008         EN 61000-4-4:2012
                                 EN 55022:2010/AC:2011           EN 61000-4-5:2014
                                 EN 55024:2010                   EN 61000-4-6:2014
                                 EN 61000-4-2:2009               EN 61000-4-11:2004
 FlexDSL Telecommunications AG                                                                                          Tel: +41 44 741 52 90
 Steinackerstrassse 31                                                                                                  Fax: +41 44 741 52 93
 8902 Urdorf                                                                                                            Email: info@flexdsl.ch
 Switzerland                                                       Page 8/9                                              Web: www.flexdsl.ch
                                 All manuals and user guides at all-guides.com
Available Models
 Ordering Code                      Interfaces               Power       Attention!
                                                             Supply
 FG-PAM-RAIL2N-2E1B/2Eth, V81       2xDSL 2xE1 2xETH         38-230VDC
 FG-PAM-RAIL2N-2E1B/2Eth-24V, V81   2xDSL 2xE1 2xETH         18-230VDC
 FG-PAM-RAIL2N-2Eth, V83            2xDSL 2xETH              38-230VDC   G.703 connector has no function (NI 3/4)
 FG-PAM-RAIL2N-2Eth-24V, V83        2xDSL 2xETH              18-230VDC   G.703 connector has no function (NI 3/4)
 FG-PAM-RAIL4N-4Eth, V84            4xDSL 4xETH              38-230VDC   xDSL connector has 2 DSL interfaces
 FG-PAM-RAIL4N-4Eth-24V, V84        4xDSL 4xETH              18-230VDC   xDSL connector has 2 DSL interfaces
 FG-PAM-RAIL4N-4Eth-24V, V84I       4xDSL 4xETH              18-230VDC
 FG-PAM-RAIL4N-3Eth,V84S            4xDSL 2xETH+1SFP         38-230VDC   xDSL connector has 2 DSL interfaces
 FG-PAM-RAIL4N-3Eth-24V,V84S        4xDSL 2xETH+1SFP         18-230VDC   xDSL connector has 2 DSL interfaces
 FG-PAM-RAIL4N-3Eth-24V,V84S3       4xDSL 2xETH+1SFP         18-300VDC   xDSL connector has 2 DSL interfaces
 FG-PAM-RAIL2N-4Eth-24V, V84IS      2xDSL 2xETH+2SFP         18-230VDC
 FG-PAM-RAIL4N-4Eth-24V, V84IS      4xDSL 2xETH+2SFP         18-230VDC
 FG-PAM-RAIL2N-V24/2Eth-24V, V88    2xDSL 2xETH 1xV24        18-230VDC
 FG-PAM-RAIL2N-485/2Eth-24V, V88    2xDSL 2xETH 1xRS-485     18-230VDC
 FG-PAM-RAIL2N-N64/2Eth-24V, V88    2xDSL 2xETH 1xN64        18-230VDC
 FlexDSL Telecommunications AG                                                                         Tel: +41 44 741 52 90
 Steinackerstrassse 31                                                                                 Fax: +41 44 741 52 93
 8902 Urdorf                                                                                           Email: info@flexdsl.ch
 Switzerland                                           Page 9/9                                         Web: www.flexdsl.ch