VKK2-8,
Data Sheet
VKK2R-8
Junction boxes
Special features
− Parallel connection of up to
8 load cells
− Corner balancing via integrated
resistor network
− EMC-proof according to
EN 45 501 and EN 61 323 due to
HBM shielding method
− Degree of protection IP65 to
EN 60 529
− Expandable to more than eight
load cells
− VKK2R-8 with stainless housing
Dimensions (in mm; 1 mm= 0.03937 inches)
37.5 *
250 100
260 110
128
* with rubber seal
(mounted state)
Mounting direction
∅7
0
25
50
75
100
125
150
175
200
7x M12, a.f. 14 for 2x M16, a.f. 17 for
264.1
cable ∅ 4 ... 6.5 mm cable ∅ 5 ... 9 mm
278
B1239-1.3 en
Corner load balancing
Input: Output:
Load cells 1 ... 8 Amplifier
Sense (+)
Excitation (+)
8 7 2 1
Excitation (−)
Sense (−)
0.22 Ω 0.22 Ω 0.22 Ω 0.22 Ω
0.39 Ω 0.39 Ω 0.39 Ω 0.39 Ω
0.82 Ω 0.82 Ω 0.82 Ω 0.82 Ω
1.50 Ω 1.50 Ω 1.50 Ω 1.50 Ω
3.00 Ω 3.00 Ω 3.00 Ω 3.00 Ω
Signal (−)
Signal (+)
Specifications
Type VKK2-8 VKK2R-8
Resistor network for corner load balancing Ω 0.22...5.93 (in 30 steps)
Max. permissible voltage V 18
Nominal temperature range −20...+85
Operating temperature range °C
C −20...+85
Storage temperature range −40...+85
Interference immunity check
Electromagnetic field (26...1000 MHz) V/m 10
Burst (to connected cables) V 1000
Electrostatic discharge (to housing) V 6000
Weight, approx. kg 1
Max. wire cross section of cable strands mm2 1.5
Degree of protection IP65 (dust−tight and protected against water jets)
according to EN 60529
(IEC 529)
Materials: Housing powder−coated steel sheet stainless steel
Housing:
RAL 7035
Sleeve nut 7 M12, a.f.14, 2 M16, a.f.17
nickel−plated brass
Clamping cone Neoprene
Modifications reserved. Hottinger Baldwin Messtechnik GmbH