0% found this document useful (0 votes)
169 views5 pages

Isolated Footing Design

This document provides design details for an isolated square footing (Footing-1). It summarizes the key dimensions of the footing and column, assumed loads, load factors, material properties, and checks calculations to verify the adequacy of the footing for bearing capacity, shear, flexure, development length, and bearing on the footing. Reinforcing details are also provided. A sketch of the footing with dimensions and reinforcement is included.

Uploaded by

MJ Abunaga
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
169 views5 pages

Isolated Footing Design

This document provides design details for an isolated square footing (Footing-1). It summarizes the key dimensions of the footing and column, assumed loads, load factors, material properties, and checks calculations to verify the adequacy of the footing for bearing capacity, shear, flexure, development length, and bearing on the footing. Reinforcing details are also provided. A sketch of the footing with dimensions and reinforcement is included.

Uploaded by

MJ Abunaga
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 5

DESIGN OF ISOLATED FOOTING

PROJECT : PROJECT NO.

CHECKED BY: DATE


LOCATION :
PREP'D BY: ETA DATE
SUBJECT : Footing-1 (F-1)

Footing Dimensions MATERIALS LOAD FACTORS


L 1.80 M fc' MPa24.00 D 1.50 M DL as per code
B 1.80 M fy 275.00
MPa qnet 123.00 kPa LL as per code
t 400 mm qa 150.00
kPa WTftg 31.10 kN EQ as per code
c. c. 75 mm d soil 18.00
kN/M3 b 0.85 WL as per code
Column Dimensions GRAVITY LOADS - SERVICE
CL 400 mm Axial Loads Moment X Moment Y
CB 300 mm PG 309.20 kN MXG 0.00 kN-M MYG 0.00 kN-M
Reinforcing Bar Size GRAVITY + LATERAL LOADS - SERVICE
Ø@L 16 mm PG+L 309.20 kN MXG+L 0.00 kN-M MYG+L 0.00 kN-M
Ø@B 16 mm ULTIMATE LOADS
No. of Reinforcing Bar PULT 402.37 kN MXULT 0.00 kN-M MYULT 0.00 kN-M
NL 14 No. of c.c. - conc. cover DL - Dead Load EQ - Earthquake Load D - depth of soil if considered

NB 14 bars NL/NB- no. of bars along L or B LL - Live Load WL - Wind Load d soil - soil density if considered

CHECK FOR BEARING CAPACITY


A. GRAVITY LOADS
P 6Mx 6My
q = + +
A LB2 BL2 P
CL
q = 105.03 < qnet = 123 ok
SOIL
CB
B. GRAVITY + LATERAL LOADS
P 6Mx 6My
q = + +
A LB2
BL2
D
q = 105.03 < 1.3qnet = 159.9 ok
d Mx c
X
d = 301 mm fua = 124.19 kPa My
Pu = 402.37 kN fub = 124.19 kPa B
Mux = 0.00 Kn-M fuc = 124.19 kPa t
Y
Muy = 0.00 Kn-M fud = 124.19 kPa a L b
Pu/LB = 124.19 kPa fuave. = 124.19 kPa

CHECK FOR ONE WAY SHEAR (BEAM SHEAR@CRITICAL SECTION)


0.399 0.449
Vu = fumax[(L-CL)/2-d][(B-CB)/2-d] = 22.24845 kN nu = Vu/fbd = 0.19 MPa
na = fc' / 6 = 0.82 MPa > nu = 0.19 ok

CHECK FOR TWO WAY SHEAR (PUNCHING SHEAR)


0.421301 2.604
Vu = Pu-qu*Ap = 350.0494 kN np = Vu/fbd = 0.53 MPa
na = fc' / 3
= 1.63 MPa > np = 0.53 ok
CHECK FOR FLEXURAL (BENDING) CAPACITY
REINFORCEMENT ALONG L DIRECTION REINFORCEMENT ALONG B DIRECTION
As = 2,814.87 mm2 As = 2,814.87 mm2
r = 0.00520 r = 0.00520
rmin= 0.00509 < r ok rmin = 0.00509 < r ok
rmax= 0.03243 > r ok rmax = 0.03243 > r ok
a = 21.08 0.7 a = 21.08 0.75
Mcap= 0.85fc'aBd(1-a/2d) = 202.36 Mcap = 0.85fc'aLd(1-a/2d) = 202.36
Mu = L  CL 2 = 54.77 Mu = B  CB 2 = 62.87
qu ( B )( ) qu ( L )( )
2 2
2 2
Mcap > Mu ok Mcap > Mu ok

CHECK FOR DEVELOPMENT LENGTH


REINFORCEMENT ALONG L DIRECTION REINFORCEMENT ALONG B DIRECTION
201.06 201.06
Ldreq = 0.02Abfy = 226 mm Ldreq = 0.02Abfy = 226 mm
fc' fc'

Ldprov = [(L-CL)/2]-cc = 625 mm Ldprov = [(B-CB)/2]-cc = 675 mm

Ldprov > Ldreq ok Ldprov > Ldreq ok

CHECK FOR BEARING ON FOOTING


A1 120000 A2 2412416 4.483689 2
Pc = 0.85fc' A1 A2 = 3,427 kN > Pu = 402.37 kN adequate!
A1

SKETCH:

DIMENSION: REINFORCEMENT:
L= 1.80 m
B= 1.80 m ALONG "L" DIR. : 14-16mmØ
t= 400 mm ALONG "B" DIR. : 14-16mmØ
PAST 2.94 2.07 309.2 0 0 0
E 2.49 0.9 309.2 0 0 0
HERE
2.94 2.07 303.14 0 0 0
Story Point Load FX FY FZ MX MY MZ
BASE 11 101 2.49 0.9 309.2 0 0 0
BASE 14 101 0.25 -1.96 303.14 0 0 0
BASE 15 101 -2.94 -2.07 306.23 0 0 0
PAST 9.33 11.05 309.2 0 0 0
E 2.76 0.9 309.2 0 0 0
HERE
9.33 11.05 284.16 0 0 0
Story Point Load FX FY FZ MX MY MZ
BASE 11 101 2.49 0.9 309.2 0 0 0
BASE 11 102 -4.1 0.61 289.75 0 0 0
BASE 11 103 -4.07 0.81 289.7 0 0 0
BASE 11 104 2.76 -3.88 291.15 0 0 0
BASE 11 105 2.65 -4.85 291.43 0 0 0
BASE 14 101 0.25 -1.96 303.14 0 0 0
BASE 14 102 -6 -2 284.16 0 0 0
BASE 14 103 -5.97 -2.17 284.24 0 0 0
BASE 14 104 0.69 -9.89 288.65 0 0 0
BASE 14 105 0.55 -9.03 288.25 0 0 0
BASE 15 101 -2.94 -2.07 306.23 0 0 0
BASE 15 102 -9.33 -2.07 286.73 0 0 0
BASE 15 103 -9.3 -2.43 286.89 0 0 0
BASE 15 104 -2.71 -11.05 291.59 0 0 0
BASE 15 105 -2.83 -9.31 290.79 0 0 0
PAST 15.61 19.67 402.37 0 0 0
E 15.11 14.21 402.37 0 0 0
HERE
15.61 19.67 302.3 0 0 0
Story Point Load FX FY FZ MX MY MZ
BASE 11 201 3.14 1.6 402.37 0 0 0
BASE 11 203 -9.6 0.62 316.36 0 0 0
BASE 11 205 -9.6 0.62 316.36 0 0 0
BASE 11 202 -9.64 0.23 316.47 0 0 0
BASE 11 204 3.42 -8.31 319.13 0 0 0
BASE 11 206 15.11 0.11 315.92 0 0 0
BASE 11 207 15.06 -0.27 316.03 0 0 0
BASE 11 208 2.04 8.65 313.26 0 0 0
BASE 11 209 15.06 -0.27 316.03 0 0 0
BASE 14 201 -0.03 -2.18 394.05 0 0 0
BASE 14 203 -11.37 -2.85 310.83 0 0 0
BASE 14 205 -11.37 -2.85 310.83 0 0 0
BASE 14 202 -11.42 -2.52 310.67 0 0 0
BASE 14 204 1.32 -17.55 319.23 0 0 0
BASE 14 206 13.18 -2.79 310.86 0 0 0
BASE 14 207 13.13 -2.45 310.7 0 0 0
BASE 14 208 0.45 12.25 302.3 0 0 0
BASE 14 209 13.13 -2.45 310.7 0 0 0
BASE 15 201 -3.67 -2.34 398.39 0 0 0
BASE 15 203 -15.57 -3.25 313.35 0 0 0
BASE 15 205 -15.57 -3.25 313.35 0 0 0
BASE 15 202 -15.61 -2.56 313.04 0 0 0
BASE 15 204 -3.01 -19.67 322.3 0 0 0
BASE 15 206 9.03 -2.9 313.72 0 0 0
BASE 15 207 8.98 -2.21 313.41 0 0 0
BASE 15 208 -3.58 14.21 304.45 0 0 0
BASE 15 209 8.98 -2.21 313.41 0 0 0

You might also like