0% found this document useful (0 votes)
13 views4 pages

List

The document is a report from the SACS Joint Mesher Version 11.0.0.1 detailing the input and output files for a joint mesh operation on joint RP71. It includes parameters such as mesh intensity and member dimensions but indicates that the joint was not meshed successfully due to an error in identifying the chord. The report lists the connected members and their specifications but ultimately highlights a failure in the meshing process.

Uploaded by

bramo96
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
13 views4 pages

List

The document is a report from the SACS Joint Mesher Version 11.0.0.1 detailing the input and output files for a joint mesh operation on joint RP71. It includes parameters such as mesh intensity and member dimensions but indicates that the joint was not meshed successfully due to an error in identifying the chord. The report lists the connected members and their specifications but ultimately highlights a failure in the meshing process.

Uploaded by

bramo96
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
You are on page 1/ 4

DATE 23-JAN-2018 TIME 14:56:12 JTM PAGE 1

SACS JOINT MESHER Version 11.0.0.1


**************************************

*** JOINT MESH INPUT REPORT ***

INPUT MODEL FILE ......


C:\Users\abraham\AppData\Local\Temp\EDIJointMeshModelFile26.txt
OUTPUT MODEL FILE ....... C:\Working
NPCC\E7275\Advance Engineering\FEA\sacinp.WHT-BH2_RP_JointMesherModelFile
LISTING FILE
........EDIJointMeshListingFile.txt
JOINT TO BE MESHED ....... RP71
MESH INTENSITY ....... 1.000
NUMBER OF BRACE INTERSECTION SUBDIVISIONS ....... 1
JOINT MESH INPUT FILE ....... C:\Working
NPCC\E7275\Advance Engineering\FEA\jtminp.dat
SECTION LIBRARY FILE ....... c:\program files
(x86)\bentley\engineering\sacs 11 connect edition\aisc13th.sec
DATE 23-JAN-2018 TIME 14:56:12 JTM PAGE 2

*** JOINT MESHER INPUT ***

JTMOPT MN RP71 1.000 1

Default brace mesh length not set.


Default member mesh length not set.
Default chord mesh length not set.
Member modification tolerance not set.
Target plate size not set.
Default brace mesh type not set.
Default member mesh type not set.
Default chord mesh type not set.
DATE 23-JAN-2018 TIME 14:56:12 JTM PAGE 3

**** MEMBERS CONNECTED TO JOINT RP71 ****

MEMBER GROUP TYPE ********** SECTION


DIMENSIONS *********** SEGMENT
A B
C D E LENGTH
(CM) (CM)
(CM) (CM) (CM) (M)

1 RP11 - RP71 RP8 TUB 50.200 2.875


0.000 0.000 0.000 2.481
2 RP36 - RP71 RP8 TUB 50.200 2.875
0.000 0.000 0.000 0.500
3 RP71 - RP19 RP8 TUB 50.200 2.875
0.000 0.000 0.000 0.500

Joint not meshed successfully

* ERROR 204
* Could not identify chord