Solar Pumping Inverter: User's Manual
Solar Pumping Inverter: User's Manual
User’s Manual
Preface
In order to give full play to the product performance and guarantee the safety of user and
equipment, before installation and use, please carefully read the manual.
In order to facilitate daily inspection and maintenance of inverter and understand abnormal
reason and solutions, please keep the instruction properly.
If you have any questions or special requirements during use, please contact with our
company’s product dealer or directly contact with our company’s technical service center.
Contents
Precautions ................................................................................................................................ II
Chapter V Maintenance........................................................................................................... 34
I
Operation Instruction of BS Series Solar Pumping Inverter Precautions
Precautions
The safe operation of the product is subject to correct transportation, installation, operation,
and maintenance. Before conducting these tasks, please pay attention to relevant safety instructions.
The warnings related to safety in the manual are listed as follows:
AC Value
DC Value
Phase
In order to avoid electric shock, breack off machine with PV terminal and
AC terminal for at least 5 minutes, then contact the wire of machine output
5minutes
terminal and input terminal
Procurement Inspection
Warning
1. If the inverter is found to suffer damage or lack in component and part, do not
install it, or else it may cause accident!
Installation
Warning
II
Operation Instruction of BS Series Solar Pumping Inverter Precautions
2. Try to install it in the indoor place with ventilation opening or air interchanger. It is
forbidden to install it directly under sunshine.
3. During installation, do not discard residue of drill hole into inverter cooling find or
fan, which may affect heat dissipation.
Wiring
Danger
Warning
1. Please use specified moment of force to tighten terminal, or else it may cause fire
disaster.
2. Do not connect capacitance or phase advance LC/RC noise filter in the output end
of inverter. When the distance between inverter and motor load is over 100m, it is
advised to use output reactor.
Operation
Danger
1. Power on after confirming that the wiring is correct, or it may damage inverter or
fire disaster.
2. During electricity, do not change wiring, or else it may cause electric shock.
III
Operation Instruction of BS Series Solar Pumping Inverter Precautions
Warning
1. Before the first operation, please adjust some control parameters according to
operation instruction. Do not alter the control parameters of inverter at random, or
else it may damage the equipment.
2. During operation, the temperature of radiator is very high. Do not touch the
radiator, or else it may scald you.
3. When height above sea level exceeds 1000m, the inverter shall be used under rated
power. If the height increases by 1500m, the output current shall decreases by 10%.
Miscellaneous
Danger
IV
Operation Instruction of BSSeries Solar Pumping Inverter Product Introduction
1
Operation Instruction of BSSeries Solar Pumping Inverter Product Introduction
Electrolytic
NCC Japan
Capacitor
DSP Control
TI America
Chip
PV Fuse BUSSMAN
America
The shell of solar pumping inverter is thick. The design process is improved through
abrasive tool test for many times. The appearance is elegant and exquisite, model is
compact, and weight is proper.
solar pumping inverter integrates combiner box. It includes DC switch, lightning arrester,
fuse, and optional components. It greatly simplifies and facilitates equipment installation
and maintenance, but also effectively protects the equipment.
Multiple communication interfaces such as RS485/CAN/GPRS(optional), etc. User can
check or control the running status and running mode of the system in a remote place.
The design of solar pumping inverter selects electric supply or diesel generator as standby
inverter power supply, so as to meet the comprehensive requirements of water supply.
solar pumping inverter has complete operation protection mechanisms, including output
short circuit protection, IGBT module overcurrent protection,
acceleration/deceleration/constant speed overcurrent protection,
acceleration/deceleration/constant speed overvoltage protection, input
overvoltage/undervoltage protection, motor overload protection, inverter overload
2
Operation Instruction of BSSeries Solar Pumping Inverter Product Introduction
protection, output side phase loss protection, inverter module overheat protection,
grounding short circuit protection, and underload (anti-dry pumping) protection.
The main circuit uses power module (PIM), and the reliability is higher.
The small-power model uses completely-new aluminum shell, LCD display operation
panel, and directly-insert connection terminal. The appearance is beautiful. The heat
dissipation effect and protective properties are good.
Upper and lower water level detection and control circuit are optional.
Protection grade IP65 , temperature of service environment: -10 ~ +50˚C.
The product nameplate is located at the right lower part of inverter. The nameplate includes
important information such as product series, voltage, power grade, software version, and hardware
version. Such information provides important basis for product application, maintenance, and
after-sales service.
3
Operation Instruction of BSSeries Solar Pumping Inverter Product Introduction
Identification Introduction
1 Product Series
3 S: Single Phase
function
4
Operation Instruction of BSSeries Solar Pumping Inverter Product Introduction
Max. Recommen
Start Rated Max.AC Output
DC input ded MPP Rated output
Model voltage output output frequency
voltage voltage voltage(Vac)
(Vdc) power(W) current(A) (Hz)
(Vdc) (Vdc)
BS-550-SL
450 100-400 80 400 4 0-50/60 1PH 220V
A
BS-750-SL
450 150-400 120 750 6.3 0-50/60 1PH 220V
A
BS-1100-S
450 150-400 120 1100 8.6 0-50/60 1PH 220V
L
BS-1100-S
450 150-400 120 1100 8.6 0-50/60 1PH 220V
LA
BS-1500-S
500 200-400 120 1500 10 0-50/60 1PH 220V
L
BS-1500-S
500 200-400 120 1500 10 0-50/60 1PH 220V
LA
BS-2200-S
500 280-400 200 2200 14 0-50/60 1PH 220V
L
5
Operation Instruction of BSSeries Solar Pumping Inverter Product Introduction
BS-2200-S
500 280-400 200 2200 14 0-50/60 1PH 220V
LA
Warning: please select appropriate model according to solar cell array and motor load.
Warning: The input power in the above table refers to multi-channel total input power. The
6
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring
Whether host computer and parts are complete Inspect according to product checklist
Whether tightening parts such as bolt are loosened When necessary, use screwdriver for inspection
7
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring
Warning: most models of BSseries are hanging installation. Guarantee that the installation
8
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring
9
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring
AC Input Terminal
Water Level Terminal
10
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring
11
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring
12
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring
Use key to open the lower cover of crate. There is DC switch, water level sensor connection
terminal, GPRS (optional), and AC output terminal.
13
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring
Analog
Output
Analog
Output
Relay 1 Output
Relay 2 Output
14
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring
Terminal Introduction
Warning: the places of input sockets of DC positive pole and negative pole of different
models are different. Please confirm according to plug.
Warning: the signal marshalling sequence of AC output sockets of different models are
different. Please confirm according to the number on socket.
15
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring
in order to guarantee that the system works normally, please select wire dimension according
to the following principle.
BS-1100-SL
8.6 1HP 220V 1 1.5 2.5 4 4 4 6
A
BS-1500-SL
10 1HP 220V 1 2.5 2.5 4 4 6 6
A
16
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring
BS-2200-SL
14 1HP 220V 1.5 2.5 2.5 6 6 6 6
A
Notice: the environment temperature of the above recommended wire dimension is ≤50°C.
2.5.1 Strip the cable 6-8mm,then connect the bare wire core into core tube of connector .
2.5.2 Crimp contact barrel by using a hex crimping die.Put the contact barrel with striped cable in
the corresponding crimping notch and crimp the contact.Insert the core tube into slot of connection
until hear the voice indicating in place.
Figure 2-16
17
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring
2.5.3 Insert contact cable assembly into back of the male and female connector. tight nuts according
to the opposite direction. Now wiring is finished.
Figure 2-17
2.5.4 The PV importation that will assemble a good DC conjunction machine to make an effort to
insert Inverters carries and link OK after hearing the sound of "click".
Warning: risk of electric shock! Before shifting solar panel, disconnect pumping inverter AC
and DC. Besides, allow 5-minute internal capacitance discharging.
Impounding Reservoir
Water Well
Notice: connect water level sensor 1 and detect water shortage. Respectively connect two
signal lines of sensor with S4 and COM of I/O circuit board. When water level sensor 1 detects that
the water level of well is lower than the level set by sensor, the pumping inverter will delay for 60s,
then turn off output protection pump. The water level recovers. Wait for 600s, then the pumping
inverter re-works normally.
Notice: connect water level sensor 2 to defect whether water is full. Connect two signal
lines of sensor with S2 and COM. When water level sensor 2 detects that the water level of water
tank exceeds the level set by sensor, the pumping inverter delays for 60s and turns off output; when
water level is lower than set level, wait for 120s, then pumping inverter re-starts to work normally.
19
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control
20
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control
Display current
operation data
↓ Inverter’s setting
frequency Show: 50.00Hz
21
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control
Display current
operation data
Inverter’s busbar
↓ voltage Show: 340.1V
Display current
operation data
Inverter’s output
↓
voltage
Show: 219V
Display current
operation data
↓ Invertor’s output
current
Show: 6.4A
Display current
↓ operation data
Inverter’s
revolving speed
Show: 1500rpm
Display current
↓ operation data
Inverter’s output
power percentage Show: 79.1%
Display current
↓ operation data
Inverter’s PV
voltage Show: 245.6V
↓ Display current
operation data
Inverter’s PV
current Show: 7.3A
↓
Display current
operation data
Inverter’s output
frequency Show: 50.00Hz
22
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control
1: Keyboard manual work mode: menu S00. Setting S00.01=0. Press key
to operate. Press key for 2s, then the inverter stop working.
2: Fully-automatic work mode: menu S00. Setting S00.01=1. When sunlight is strong enough,
the inverter will automatically trace maximum power point. Under such mode, refer to inverter’s
3: GPRS work mode (optional): menu S00. Setting S00.01=2. Under such mode, bind
cellphone number. Send messages to set startup, shutdown, parameter inquiry, etc.
Warning: do not change menu S00 parameters. The default mode is fully-automatic
work mode.
1. Conduct wiring according to system diagram and check whether wiring is correct or not.
After confirming it, turn on Q2.
23
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control
Impounding
Reservoir
(a) Setting S00.01=0. Command code channel is keyboard manual mode instruction.
(b) Set water pump nameplate parameters: S02.01 motor rated power value; S02.02 motor rated
power value; S02.04 motor rated voltage value; S02.05 motor rated current value.
3. Set the wire number of single-phase water pump. Three-wire water pump sets S16.00=0. The
two-wire water pump sets S16.00=1 (BS-550~BS-1100 factory default S16.00=1,
BS-1500~BS-2200 factory default S16.00=0).
4. After finishing parameter setting of water pump, set S00.01=1. The operation code channel is
altered as original automatic mode instruction.
24
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control
See the following figure. The settings of nameplate parameters of water pump are listed as
follows (for example: 2.2KW inverter drives 1.5KW water pump):
Initial condition:
non-control parameter
display
Enter main interface of
↓
parameters. Press
“OK” key for 2s to
alter S00 group
Show: S00 group parameters
parameters
↓
Press “OK” key to
enter next-level
parameter S00.00
Show: S00.00
↓
Press page-up key to
enter S00.01
Show: S00.01
↓
Press “OK ” key to
enter S00.01 (original
parameter is 1)
Show: 1
↓
Press “page-down”
key to alter it as 0
(keyboard manual
control mode) Show: 0
↓
Press “OK” key to
confirm. The display
screen will show the
next parameter. Show: S00.03
↓
25
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control
↓
Press “OK” key to
save setting
Show: S00 group parameters
26
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control
Press “page-down”
↓ key to enter S00 group
parameters
Show: S00 group parameters
27
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control
5. After finishing all parameter settings, turn off Q2 of DC switch. After display screen is OFF for
5 minutes, turn on AC output. Then turn on DC input switch Q2. Wait for 60s. The machine will
operate automatically.
1. Conduct wiring according to systematic diagram and check whether the wiring is correct.
28
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control
Power grid
Solar cell panel
Water level
switch
inverter
DC switch
Solar pumping
Impounding
Reservoir
4. After finishing all parameter settings, turn off Q1 of AC input switch. After display screen is
off for 5 minutes, turn on AC output switch. Then turn on Q1 of AC input switch. Wait for 60s. The
equipment will operate automatically.
5. When solar power supply is used, turn off Q1 and turn on Q2 (Attention: it is forbidden to
turn on Q1 and Q2 at the same time).
Warning: do not change inverter’s control parameters at random, or else the system may not
work normally.
29
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control
30
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control
Rated power of
Model
S02.01 asynchronous 0.1 ~ 3000.0 0.1 ~ 3000.0kW
confirmation
motor
Rated frequency
S02.02 of asynchronous 0.01 ~ S00.03 0.01 ~ S00.03 50.00Hz
motor
Rated voltage of
Model
S02.04 asynchronous 0 ~ 1200 0 ~ 1200V
confirmation
motor
Rated current of
Model
S02.05 asynchronous 0.8 ~ 6000 0.8 ~ 6000A
confirmation
motor
31
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control
When failure or protection happens, the failure or protection needs to reset the inverter. Power
off input power supply, then power on it. If the failure is not still settled, please contact with
manufacturer to settle it.
32
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control
Warning: before resetting, completely find out failure reasons and eliminate the reasons. If it
fails to reset or suffers failure again, find out the reasons. The continuous resetting will damage
inverter.
33
Chapter V Maintenance
34
5.2 Inspection and Replacement of Quick-wear Parts
5.2.1 Filter Capacitor
The pulsating current of main loop will affect the performance of filter capacitor of aluminium
electrolysis. The affected degree and environment temperature are related to service environment.
Under normal conditions, the inverter shall change electrolytic capacitor once every 10 years. When
electrolyte of electrolytic capacitor leaks, safety valve emits, or capacitance expands, replace it
immediately.
5.2.2 Fax cooling
In BS series pumping inverter, the inverter above BS-22K has cooling fan inside. The service
life of cooling fan is about 15000 hours. If fan has abnormal nose or generates vibration, replace it
immediately.
35
Quality Assurance
Warranty Policy:
Warranty period: Our company provides series solar pumping inverter with warranty period
of 24 months. The systematic components provided by our company have 12-month warranty
period.
Starting date of warranty period: the date when user gets goods from our dealer.
Warranty proof: product series number and local dealer’s shipment invoice.
Notice: if client does not provide shipment invoice and other documents, our company will use
the date which is 2 months after delivery date, as starting date of warranty period.
Scope: during warranty period, the scope and responsibility of any damage shall be appraised
by dealer and our company.
Warranty principle:
In order to provide our company final users with better services, all the dealers authorized
shall reply user’s warranty request. During warranty period, the dealer will replace all defective
products and parts in aspects of design and production.
(1) Warranty card is not sent to dealer or our company.
(2) Product change, design alteration, or component replacement is not approved by our
company.
(3) Alter, change or try to repair it. The serial number is wiped out or does not has our
company technician’s seal.
(4) Wrong installation and debugging
(5) Does not abide by proper safety regulation (CQC standards, etc.)
(6) The product is improperly stored and damaged by final user.
(7) Transportation damage. During transportation, the paint is scratched. During unloading, if
enough evidence is available, apply in insurance company as soon as possible.
(8) Fail to abide by user’s manual, installation guidance, and maintenance regulation.
(9) Incorrect use or improper operation
(10) Shortage of ventilating device
(11) The product maintenance procedure does not abide by or implement an acceptable
standard.
(12) Force majeure (such as lightning, over-voltage, thunderstorm, fire disaster)
36
If claim exceeds the power quoted in warranty principle,our company shall not undertake legal
responsibilities, including the following conditions: claim compensation due to direct or indirect
damaged caused by defective equipment; claim compensation due to the damage caused by removal
and installation; profit loss not specified in our company warranty scope.
Warranty and Claim Procedure:
Please send a simple failure description report to our company local dealer. If we agree to
replace, we will issue an equivalent replacement device according to model and year length. The
rest warranty rights will be transferred to replacing equipment. Under such condition, as your power
has been filed in our company, you will not receive a new certification. The substitute goods will be
delivered within 2 working days. The defective equipment is to use the transportation packaging to
transport to dealer. If on-site re-installation is necessary, the end-user shall consult with dealer in
advance. All maintenance services during warranty period are free of charge.
37
Warranty Card
Contact
Client Name
Person
Client Address Contact Tel.
Product Procurement
Specification Date
Warranty
Date
Equipment Code (since
production
date)
Distribution Unit
(Seal)
Packing List
(3) Patch plug of positive pole of solar cell array quantity: one
(4) Patch plug of negative pole of solar cell array quantity: one