Solar Pumping Inverter: User's Manual

This document is the user manual for a solar pumping inverter. It provides instructions on safe installation, wiring, operation, maintenance and failure diagnosis of the inverter. The manual contains chapters covering product introduction, installation and wiring, operation control, failure diagnosis, maintenance, and safety precautions. It is intended to ensure the inverter is used properly and safely.

Uploaded by

Avs Electron
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
320 views44 pages

Solar Pumping Inverter: User's Manual

This document is the user manual for a solar pumping inverter. It provides instructions on safe installation, wiring, operation, maintenance and failure diagnosis of the inverter. The manual contains chapters covering product introduction, installation and wiring, operation control, failure diagnosis, maintenance, and safety precautions. It is intended to ensure the inverter is used properly and safely.

Uploaded by

Avs Electron
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 44

Solar Pumping Inverter

User’s Manual
Preface

In order to give full play to the product performance and guarantee the safety of user and
equipment, before installation and use, please carefully read the manual.

In order to facilitate daily inspection and maintenance of inverter and understand abnormal
reason and solutions, please keep the instruction properly.

If you have any questions or special requirements during use, please contact with our
company’s product dealer or directly contact with our company’s technical service center.

If the manual contents change, we may not offer notice.


Operation Instruction of BS Series Solar Pumping Inverter Precautions

Contents
Precautions ................................................................................................................................ II

Chapter I Product Introduction ............................................................................................ 1

1.1 Introduction to Solar Pumping System ................................................................................ 1

1.2 Product Characteristics ........................................................................................................ 2

1.3 Inverter Specification........................................................................................................... 3

Chapter II Installation and Wiring .......................................................................................... 7

2.1 Procurement Inspection ....................................................................................................... 7

2.2 Dimension and Weight......................................................................................................... 7

2.3 Installation Diagram ............................................................................................................ 9

2.4 Wiring Diagram ................................................................................................................. 10

2.5 Assemble DC Connector.................................................................................................... 17

2.6 Introduction to the Wiring of Water Level Sensor ............................................................. 17

Chapter III Operation Control ............................................................................................... 20

3.1 Panel Layout and Introduction........................................................................................... 20

3.2 Panel Operation Method .................................................................................................... 21

3.3 Work Mode ........................................................................................................................ 23

3.4 Introduction to the Procedure of Wiring and Debugging .................................................. 23

Chapter IV: Failure Diagnosis ................................................................................................ 32

4.1 Explanation and Solution for Fault Code .......................................................................... 32

Chapter V Maintenance........................................................................................................... 34

5.1 Daily Inspection and Maintenance .................................................................................... 34

5.2 Inspection and Replacement of Quick-wear Parts ............................................................. 35

5.3 Storage and Maintenance ................................................................................................... 35

Quality Assurance .................................................................................................................... 38

Warranty Card ......................................................................... ¡Error! Marcador no definido.

I
Operation Instruction of BS Series Solar Pumping Inverter Precautions

Precautions
The safe operation of the product is subject to correct transportation, installation, operation,
and maintenance. Before conducting these tasks, please pay attention to relevant safety instructions.
The warnings related to safety in the manual are listed as follows:

Grounding Wire of Equipment

AC Value

DC Value

Phase

Before operating inverter, please read the instruction.

In order to avoid electric shock, breack off machine with PV terminal and
AC terminal for at least 5 minutes, then contact the wire of machine output
5minutes
terminal and input terminal

Warning: when machine works, the temperature of metal shell may be


very high.

 Procurement Inspection

Warning
1. If the inverter is found to suffer damage or lack in component and part, do not
install it, or else it may cause accident!

 Installation

Warning

1. In order to guarantee good effect of convection cooling, the inverter shall be


installed vertically. Keep at least 10cm space between upward side and downward
side.

II
Operation Instruction of BS Series Solar Pumping Inverter Precautions

2. Try to install it in the indoor place with ventilation opening or air interchanger. It is
forbidden to install it directly under sunshine.
3. During installation, do not discard residue of drill hole into inverter cooling find or
fan, which may affect heat dissipation.

 Wiring

Danger

1. The wiring shall be conducted by qualified electric technician, or it may cause


electric shock or fire disaster.
2. Before wiring, please confirm that the input power has been cut off, or else it may
cause electric shock or fire disaster.
3. The grounding terminal must be grounded reliably, or else the inverter shell may
have electricity.
4. The solar array, motor load, and inverter model selection shall be reasonable, or
else it may damage equipment.

Warning

1. Please use specified moment of force to tighten terminal, or else it may cause fire
disaster.
2. Do not connect capacitance or phase advance LC/RC noise filter in the output end
of inverter. When the distance between inverter and motor load is over 100m, it is
advised to use output reactor.

 Operation

Danger

1. Power on after confirming that the wiring is correct, or it may damage inverter or
fire disaster.
2. During electricity, do not change wiring, or else it may cause electric shock.

III
Operation Instruction of BS Series Solar Pumping Inverter Precautions

Warning

1. Before the first operation, please adjust some control parameters according to
operation instruction. Do not alter the control parameters of inverter at random, or
else it may damage the equipment.
2. During operation, the temperature of radiator is very high. Do not touch the
radiator, or else it may scald you.
3. When height above sea level exceeds 1000m, the inverter shall be used under rated
power. If the height increases by 1500m, the output current shall decreases by 10%.

 Miscellaneous

Danger

1. Assign qualified electric technician for maintenance and inspection.


2. During power-up state, do not remove the inverter. After outage, wait for 5 minutes
at least, then conduct maintenance and inspection, so as to avoid that the residual
voltage on electrolytic capacitor of major loop may cause damage to people.
3. It is forbidden to transform the inverter without authorization, or else it may
damage personnel or equipment.
4. When handling scrapped inverter, please dispose the inverter as industrial waste.
The inner electrolytic capacitor may explode during burning. Some components and
parts may generate hazardous and harmful gas during combustion.

IV
Operation Instruction of BSSeries Solar Pumping Inverter Product Introduction

Chapter I Product Introduction

1.1 Introduction to Solar Pumping System


Solar Pumping System is widely applied in domestic water, agricultural irrigation, forestry
watering, desert control, grassland animal husbandry, island water supply, water treatment project,
etc. During recent years with the enhancement of new energy utilization, solar pumping system is
widely applied in the landscape and water spray system of municipal works, urban square, garden
sightseeing, tourist resort, hotel, and residential community. The system consists of solar cell array,
pumping inverter, and water pump(figure 1-1). Based on the design philosophy of saving water first,
the system omits energy storing device such as accumulator.

DC Voltage Single-Phase AC Voltage

Figure 1-1 Structure of Solar Pumping System


The solar cell array is made from the series connection and parallel connection of several solar
cell modules, which absorb solar radiation energy and transform it into electric energy, so as to
supply electric power for the whole system. The pumping inverter controls and regulates the
operation of the system, transforms the direct current of solar cell array into alternating current to
drive water pump. In addition, according to the change of sunlight intensity, regulate output
frequency timely, to realize MPPT (Maximum Power Point Tracking). The water pump is driven by
Single-phase AC motor. It pumps water from deep well, river, and lake, then inject water into water
storage tank/pool, or directly connect with irrigation system or fountain system, etc. According to
actual requirements of system and installation, different types of water pumps such as centrifugal
pump, axial flow pump, mixed-flow pump, or deep-well pump can be used.

1
Operation Instruction of BSSeries Solar Pumping Inverter Product Introduction

1.2 Product Characteristics


On the basis of many-year research, development, and experiment, the pumping inverter
(Figure 1-2) independently developed and produced by our company has the following advantages:
 Use independently-developed dynamic VI MPPT (Maximum Power Point Tracking)
control method. The response speed is fast. Operation is stable and reliable. It solves the
following problems: tracking effect is poor when sunlight intensity rapidly; operation is not
stable; water hammer damage.
 All digital control. It has complete automatic operation, data storage, and complete
protection functions.
 Solar Pumping Inverter is specially designed for solar water pump. The inner structure is
more reasonable and professional.
 All key parts used in solar pumping inverter are made by international famous brands. The
quality is reliable, service life is long, and quality assurance period is long.
Component
Manufacturer Country
and Part

IGBT Module Infineon Germany

Electrolytic
NCC Japan
Capacitor

EMI Filter VAC Germany

DSP Control
TI America
Chip

PV Fuse BUSSMAN
America

 The shell of solar pumping inverter is thick. The design process is improved through
abrasive tool test for many times. The appearance is elegant and exquisite, model is
compact, and weight is proper.
 solar pumping inverter integrates combiner box. It includes DC switch, lightning arrester,
fuse, and optional components. It greatly simplifies and facilitates equipment installation
and maintenance, but also effectively protects the equipment.
 Multiple communication interfaces such as RS485/CAN/GPRS(optional), etc. User can
check or control the running status and running mode of the system in a remote place.
 The design of solar pumping inverter selects electric supply or diesel generator as standby
inverter power supply, so as to meet the comprehensive requirements of water supply.
 solar pumping inverter has complete operation protection mechanisms, including output
short circuit protection, IGBT module overcurrent protection,
acceleration/deceleration/constant speed overcurrent protection,
acceleration/deceleration/constant speed overvoltage protection, input
overvoltage/undervoltage protection, motor overload protection, inverter overload
2
Operation Instruction of BSSeries Solar Pumping Inverter Product Introduction

protection, output side phase loss protection, inverter module overheat protection,
grounding short circuit protection, and underload (anti-dry pumping) protection.
 The main circuit uses power module (PIM), and the reliability is higher.
 The small-power model uses completely-new aluminum shell, LCD display operation
panel, and directly-insert connection terminal. The appearance is beautiful. The heat
dissipation effect and protective properties are good.
 Upper and lower water level detection and control circuit are optional.
 Protection grade IP65 , temperature of service environment: -10 ~ +50˚C.

Figure 1-2 BS Series Pumping Inverter

1.3 Inverter Specification


1.3.1 Introduction to Nameplate and Model

The product nameplate is located at the right lower part of inverter. The nameplate includes
important information such as product series, voltage, power grade, software version, and hardware
version. Such information provides important basis for product application, maintenance, and
after-sales service.

3
Operation Instruction of BSSeries Solar Pumping Inverter Product Introduction

Figure 1-3 Introduction to Product Nameplate and Model

Identification Introduction

1 Product Series

2 Rated Power (W) of Motor

3 S: Single Phase

4 Output Voltage (L: 220V)

5 A: with electric supply function None: without electric supply

function

Warning: do not rip out product nameplate label.

4
Operation Instruction of BSSeries Solar Pumping Inverter Product Introduction

1.3.2 Product Specification and Technical Index

Max. Recommen
Start Rated Max.AC Output
DC input ded MPP Rated output
Model voltage output output frequency
voltage voltage voltage(Vac)
(Vdc) power(W) current(A) (Hz)
(Vdc) (Vdc)

BS-550-SL 450 100-400 80 400 4 0-50/60 1PH 220V

BS-550-SL
450 100-400 80 400 4 0-50/60 1PH 220V
A

BS-750-SL 450 150-400 120 750 6.3 0-50/60 1PH 220V

BS-750-SL
450 150-400 120 750 6.3 0-50/60 1PH 220V
A

BS-1100-S
450 150-400 120 1100 8.6 0-50/60 1PH 220V
L

BS-1100-S
450 150-400 120 1100 8.6 0-50/60 1PH 220V
LA

BS-1500-S
500 200-400 120 1500 10 0-50/60 1PH 220V
L

BS-1500-S
500 200-400 120 1500 10 0-50/60 1PH 220V
LA

BS-2200-S
500 280-400 200 2200 14 0-50/60 1PH 220V
L

5
Operation Instruction of BSSeries Solar Pumping Inverter Product Introduction

BS-2200-S
500 280-400 200 2200 14 0-50/60 1PH 220V
LA

Warning: please select appropriate model according to solar cell array and motor load.

Warning: The input power in the above table refers to multi-channel total input power. The

maximum input DC current of each group shall not exceed 15A.

6
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring

Chapter II Installation and Wiring

2.1 Procurement Inspection


Our company has strict quality assurance system in aspects of product manufacturing,
packaging, etc. In case of abnormal condition, please contact with our company’s product dealer, or
contact with our company’s technical service center. We will provide you with solution as soon as
possible. When you get the products, please confirm the following items:

Inspection Item Inspection Method

Whether it accords with ordered products Inspect nameplate of product

Whether it is damaged or falls off Check the overall appearance

Whether host computer and parts are complete Inspect according to product checklist

Whether tightening parts such as bolt are loosened When necessary, use screwdriver for inspection

2.2 Dimension and Weight

Figure 2-1 Product Appearance and Installation Dimension

7
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring

Product Specification Parameter:

Appearance and installation dimension (mm)


Model Weight(Kg)
L W H

BS-550-SL 5 418 288 152

BS-550-SLA 5 418 288 152

BS-750-SL 8 418 288 152

BS-750-SLA 8 418 288 152

BS-1100-SL 8 418 288 152

BS-1100-SLA 8 418 288 152

BS-1500-SL 10 453 288 152

BS-1500-SLA 10 453 288 152

BS-2200-SL 10 453 288 152

BS-2200-SLA 10 453 288 152

Warning: most models of BSseries are hanging installation. Guarantee that the installation

backboard can bear the weight of inverter.

8
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring

2.3 Installation Diagram

Figure 2-2 Installation Dimension of BS-550-SL/SLA to 2200-SL/SLA

Figure 2-3 Install Safety Nut

9
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring

Figure 2-4 Correct Arrangement Diagram of Inverter

2.4 Wiring Diagram


2.4.1 Introduction to Crate Socket

Figure 2-5 BS-550-SL/SLA to 1100-SL/SLA Wiring Terminal

PV Input Terminal AC Output Terminal

AC Input Terminal
Water Level Terminal

Figure 2-6 BS-1500-SL/SLA to 2200-SL/SLA Wiring Terminal

10
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring

2.4.2 Wiring Diagram of Two-Wire Water Pump

Figure 2-7 BS-550-SL to 1100-SL Wiring Diagram

Figure 2-8 BS-550-SLA to 1100-SLA Wiring Diagram

11
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring

Figure 2-9 BS-550-SL/SLA to 1100-SL /SLA Wiring Diagram

2.4.3 Wiring Diagram of Three-Wire Water Pump

Figure 2-10 BS-1500-SL to 2200-SL Wiring Diagram

12
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring

Figure 2-11 BS-1500-SLA to 2200-SLA Wiring Diagram

Figure 2-12 BS-1500-SL/SLA to2200-SL/SLA Wiring Diagrams

Use key to open the lower cover of crate. There is DC switch, water level sensor connection
terminal, GPRS (optional), and AC output terminal.

13
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring

Analog
Output

Analog
Output

Relay 1 Output

Relay 2 Output

Figure 2-13 A/O Terminal Diagram

Figure 2-14 I/O Terminal Diagram

14
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring

Terminal Introduction

Socket Terminal Introduction Wiring Introduction


Connect with the positive pole of solar
PV+
DC array
Input Connect with the negative pole of solar
PV-
array
PE Connect with protective ground wire

AC U Connect with motor U phase


Output V Connect with motor V phase

W Connect with motor W phase

+12V Power supply of water level sensor

COM Common signal grounding


Auto power signal (factory settings have
Water Level Sensor S1
been set)
Input (Switch Value)
Water-full signal of water tower
S2
(switching value)
Water shortage signal of water
S4
tower (switching value)
+10V Power supply of water level sensor

GND Common signal ground wire


Water-full signal of water tower (analog
AI2
quantity)
Water shortage signal of water tower
Water Level Sensor AI3
(analog quantity)
Input (Analog Quantity)
RS485+ 485 communication

RS485- 485 communication

CANAH CAN communication

CANAL CAN communication

Warning: the places of input sockets of DC positive pole and negative pole of different
models are different. Please confirm according to plug.
Warning: the signal marshalling sequence of AC output sockets of different models are
different. Please confirm according to the number on socket.

15
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring

2.4.4 Recommended Diameter of Wire (mm2)

in order to guarantee that the system works normally, please select wire dimension according
to the following principle.

Recommende Output length≤ length≤ length≤ length≤ length≤ length≤ length≤

d output voltage(V) 30m 60m 90m 120m 150m 180m 210m


model
current(A)

BS-550-SL 4 1HP 220V 0.75 1 1.5 2.5 2.5 2.5 4

BS-550-SLA 4 1HP 220V 0.75 1 1.5 2.5 2.5 2.5 4

BS-750-SL 6.3 1HP 220V 0.75 1.5 2.5 2.5 4 4 4

BS-750-SLA 6.3 1HP 220V 0.75 1.5 2.5 2.5 4 4 4

BS-1100-SL 8.6 1HP 220V 1 1.5 2.5 4 4 4 6

BS-1100-SL
8.6 1HP 220V 1 1.5 2.5 4 4 4 6
A

BS-1500-SL 10 1HP 220V 1 2.5 2.5 4 4 6 6

BS-1500-SL
10 1HP 220V 1 2.5 2.5 4 4 6 6
A

16
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring

BS-2200-SL 14 1HP 220V 1.5 2.5 2.5 6 6 6 6

BS-2200-SL
14 1HP 220V 1.5 2.5 2.5 6 6 6 6
A

Note: the unit of above wire diameter is mm2.

Notice: the environment temperature of the above recommended wire dimension is ≤50°C.

Notice: large-power wall-mounted model uses multiple-channel DC input. The dimension

of DC wire of each channel shall be selected according to the above table.

2.5 Assemble DC Connector

2.5.1 Strip the cable 6-8mm,then connect the bare wire core into core tube of connector .

Figure 2-15 DC Line connects with wiring board

2.5.2 Crimp contact barrel by using a hex crimping die.Put the contact barrel with striped cable in
the corresponding crimping notch and crimp the contact.Insert the core tube into slot of connection
until hear the voice indicating in place.

Figure 2-16

17
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring

2.5.3 Insert contact cable assembly into back of the male and female connector. tight nuts according
to the opposite direction. Now wiring is finished.

Figure 2-17

2.5.4 The PV importation that will assemble a good DC conjunction machine to make an effort to
insert Inverters carries and link OK after hearing the sound of "click".

Warning: risk of electric shock! Before shifting solar panel, disconnect pumping inverter AC
and DC. Besides, allow 5-minute internal capacitance discharging.

2.6 Introduction to the Wiring of Water Level Sensor

DC Switch Connect S2 and COM

Water Level Sensor 2

Impounding Reservoir

Connect Single-Phase Output

Connect S4 and COM


Water Pump

Water Level Sensor 1

Water Well

Figure 2-18 Wiring Diagram of Water Level Sensor


18
Operation Instruction of BS Series Solar Pumping Inverter Installation and Wiring

Notice: connect water level sensor 1 and detect water shortage. Respectively connect two

signal lines of sensor with S4 and COM of I/O circuit board. When water level sensor 1 detects that
the water level of well is lower than the level set by sensor, the pumping inverter will delay for 60s,
then turn off output protection pump. The water level recovers. Wait for 600s, then the pumping
inverter re-works normally.

Notice: connect water level sensor 2 to defect whether water is full. Connect two signal

lines of sensor with S2 and COM. When water level sensor 2 detects that the water level of water
tank exceeds the level set by sensor, the pumping inverter delays for 60s and turns off output; when
water level is lower than set level, wait for 120s, then pumping inverter re-starts to work normally.

19
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control

Chapter III Operation Control

3.1 Panel Layout and Introduction


Solar Pumping Inverter uses LCD operation panel. The operation panel is shown in the figure,
including 3 LED lights,LCD display and 5 keys.

Figure 3-1 Keyboard Layout and Each Part Name

Indicator and Key Name Function Introduction


Operation
POWER Green Bright: Inverter Operates
Indicator
Warning
ALARM Bright: warning and terminal mode
Indicator Yellow
Failure
FAULT Red Bright: system failure
Indicator

1. Press for a short time, then the inverter starts


Operation/Stop
control;
Key
2. Press for 2s, then inverter stops control.

20
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control

Indicator and Key Name Function Introduction

1. Press for a short time to enter programming mode.


After altering parameter, “press for a short time” to
Confirm/Progra
confirm the alteration
mming Key
2. Press for 2s to return to the previous menu.

1. When control parameter displays state, increase


parameter number or parameter value;
Increment Key 2. When operation displays data state, according to
operation mode, increase output frequency or display
current operation data.
1. When control parameter displays state, press for a
short time to decrease parameter number or
parameter value.
Decrement Key
2. When operation shows data state, according to
operation mode, decrease output frequency or
display current operation data.
1. After entering mode of parameter editing, press
the key for a short time to conduct shifting;
Shift Key
2. When machine operates normally, press the key to
see the parameter of main interface.

3.2 Panel Operation Method


The operation panel display includes three modes: operation data display, control parameter
display, and historical parameter display. The default state is display state of operation data. The
default state diagram is shown as follows:

Operation Description Display

Initial status: Current Display current


running data operation data
↓ Inverter’s output
frequency Show: 50.00Hz

Display current
operation data
↓ Inverter’s setting
frequency Show: 50.00Hz
21
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control

Display current
operation data
Inverter’s busbar
↓ voltage Show: 340.1V

Display current
operation data
Inverter’s output

voltage
Show: 219V

Display current
operation data
↓ Invertor’s output
current
Show: 6.4A

Display current
↓ operation data
Inverter’s
revolving speed
Show: 1500rpm

Display current
↓ operation data
Inverter’s output
power percentage Show: 79.1%

Display current
↓ operation data
Inverter’s PV
voltage Show: 245.6V

↓ Display current
operation data
Inverter’s PV
current Show: 7.3A


Display current
operation data
Inverter’s output
frequency Show: 50.00Hz

22
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control

3.3 Work Mode


The inverter includes three work modes: keyboard manual mode, fully-automatic work mode,
GPRS work mode (optional). The default mode is fully-automatic work mode.

1: Keyboard manual work mode: menu S00. Setting S00.01=0. Press key

to operate. Press key for 2s, then the inverter stop working.
2: Fully-automatic work mode: menu S00. Setting S00.01=1. When sunlight is strong enough,

the inverter will automatically trace maximum power point. Under such mode, refer to inverter’s

operation parameter and DC switch to turn on/off the machine.

3: GPRS work mode (optional): menu S00. Setting S00.01=2. Under such mode, bind

cellphone number. Send messages to set startup, shutdown, parameter inquiry, etc.

Warning: do not change menu S00 parameters. The default mode is fully-automatic
work mode.

3.4 Introduction to the Procedure of Wiring and Debugging


3.4.1 Procedure of Power Supply Debugging of Solar Cell

1. Conduct wiring according to system diagram and check whether wiring is correct or not.
After confirming it, turn on Q2.

23
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control

Solar cell panel

Water level switch


inverter
DC switch
Solar pumping

Impounding
Reservoir

2. Conduct parameter setting for the motor

(a) Setting S00.01=0. Command code channel is keyboard manual mode instruction.

(b) Set water pump nameplate parameters: S02.01 motor rated power value; S02.02 motor rated
power value; S02.04 motor rated voltage value; S02.05 motor rated current value.

3. Set the wire number of single-phase water pump. Three-wire water pump sets S16.00=0. The
two-wire water pump sets S16.00=1 (BS-550~BS-1100 factory default S16.00=1,
BS-1500~BS-2200 factory default S16.00=0).

4. After finishing parameter setting of water pump, set S00.01=1. The operation code channel is
altered as original automatic mode instruction.

24
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control

See the following figure. The settings of nameplate parameters of water pump are listed as
follows (for example: 2.2KW inverter drives 1.5KW water pump):

Operation Description Display

Initial condition:
non-control parameter
display
Enter main interface of

parameters. Press
“OK” key for 2s to
alter S00 group
Show: S00 group parameters
parameters

Press “OK” key to
enter next-level
parameter S00.00
Show: S00.00

Press page-up key to
enter S00.01
Show: S00.01

Press “OK ” key to
enter S00.01 (original
parameter is 1)
Show: 1

Press “page-down”
key to alter it as 0
(keyboard manual
control mode) Show: 0

Press “OK” key to
confirm. The display
screen will show the
next parameter. Show: S00.03

Press “OK” key for 2s.


Quit setting. Display
↓ S00.
Show: S00 group parameters

Press “OK” key for 2s


to return to main

interface
Show: operation frequency is 50.00Hz

25
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control

Operation Description Display

Press “ON/OFF” key


for 2s to turn off
inverter.
↓ Show: setting frequency is 50.00Hz

Press “OK” key for 2s


to enter S00 group
parameter
↓ Show: S00 group parameters

Press page-up key to


enter S02 to alter

motor parameter
Show: S02 group parameters

Press “OK” key to


enter S02.01
↓ Show: S02.01
Press “SHFIT” and
and “Page-up” key to set
the rated power of
↓ water pump as 1.5kW Show: 1.5kW

Press “OK” key to


enter the next-level
↓ parameter S02.02 Show: S02.02

Press “page-up” key to


enter S02.05
↓ Show: S02.05
Press “shift” key to
and
enter interface.
Re-press “SHIFT” and

“Page-up” key to set
the rated current of Show: 7.0A
water pump as 7.0A


Press “OK” key to
save setting
Show: S00 group parameters

↓ Press “OK” key for 2s


to quit setting. Display
S02.
Show: S02 group parameters

26
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control

Operation Description Display

Press “page-up” key to


enter S16 group
↓ parameters
Show: S16 group parameters

Press “OK” key to


↓ enter S16.00
Show: S16.00
Press “OK” key to
enter S16.00 (the
↓ original default
parameter is 0) Show: 0

Press “OK” key for 2s


to return to S16.00
↓ interface
Show: S16.00

Press “OK” key for 2s


to return to S16
↓ interface
Show: S16 group parameters

Press “page-down”
↓ key to enter S00 group
parameters
Show: S00 group parameters

Press “OK” key to


enter S00.00
↓ Show: S00.00

or Press “page-up” key or


“page-down” key to
↓ enter S00.01
Show: S00.01
Press “OK” key to
enter S00.01 (the
original parameter is
0) Show: 0

27
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control

Operation Description Display



Press “page-up” key to
alter parameter as 1
(terminal automatic
control module) Show: 1

↓ Press “OK” key to


save setting. The
display screen will
show the next
Show: S00.03
parameter.

Press “OK” key for 2s
to return to S00
interface
Show: S00 group parameters

Press “OK” key for 2s


to return to main
interface.
Show: 50.00 Hz

Turn off DC switch. After
display is OFF, turn on DC
switch. Wait for 60s, then
the pumping inverter will
automatically drive water
pump (1.5kW)

5. After finishing all parameter settings, turn off Q2 of DC switch. After display screen is OFF for
5 minutes, turn on AC output. Then turn on DC input switch Q2. Wait for 60s. The machine will
operate automatically.

3.4.2 Procedure of Power Supply Debugging of Power Grid (Diesel Engine)

1. Conduct wiring according to systematic diagram and check whether the wiring is correct.

28
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control

Power grid
Solar cell panel

Water level
switch

inverter
DC switch
Solar pumping

Impounding
Reservoir

2. Turn off Q2 switch, then turn on Q1 switch.

3. After power-on, adjust motor parameter according to Item 2, 3, 4 of Article 3.4.1.

4. After finishing all parameter settings, turn off Q1 of AC input switch. After display screen is
off for 5 minutes, turn on AC output switch. Then turn on Q1 of AC input switch. Wait for 60s. The
equipment will operate automatically.

5. When solar power supply is used, turn off Q1 and turn on Q2 (Attention: it is forbidden to
turn on Q1 and Q2 at the same time).

Warning: do not change inverter’s control parameters at random, or else the system may not

work normally.
29
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control

30
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control

3.4.3 Introduction to function parameters

SN Name Scope Introduction Factory Value

0: keyboard operation code channel


(LED is off)
Operation code 1: terminal operation code channel
S00.01 0~2 1
channel (LED flickers)
2: communication operation code
channel (LED is bright)
S00.03 Maximum 10.00~600.00 S00.04~600.00Hz(400.00Hz)
50.00Hz
output frequency
S00.04 Upper limit of S00.06~S00.03 S00.05~S00.03 (the maximum
operation frequency) 50.00Hz
frequency
S00.05 Lower limit of 0.00Hz~S00.04 0.00~S00.04
operation (Upper limit of operation frequency)
14.00HZ
frequency

Rated power of
Model
S02.01 asynchronous 0.1 ~ 3000.0 0.1 ~ 3000.0kW
confirmation
motor

Rated frequency
S02.02 of asynchronous 0.01 ~ S00.03 0.01 ~ S00.03 50.00Hz
motor

Rated voltage of
Model
S02.04 asynchronous 0 ~ 1200 0 ~ 1200V
confirmation
motor

Rated current of
Model
S02.05 asynchronous 0.8 ~ 6000 0.8 ~ 6000A
confirmation
motor

Wiring method 3-wire water pump: 0 550~1100:1


S16.00 0~ 1
of water pump 2-wire water pump: 1 1.5K~2.2K:0

31
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control

Chapter IV: Failure Diagnosis

4.1 Explanation and Solution for Fault Code


BS series solar pumping inverter has complete protection. When system suffers failure, the
inverter will take protective measures: the general protective measures are to stop the output of
drive signal of motor and forbid to re-start within a certain period.

When failure or protection happens, the failure or protection needs to reset the inverter. Power
off input power supply, then power on it. If the failure is not still settled, please contact with
manufacturer to settle it.

The common failures are listed as follows:

Code Code Description Possible Reasons Countermeasures

Power off No failure

Inc over Volt


Input voltage is too Check the voltage of solar
Dec over Volt
Overvoltage high array
Con over Volt

Input voltage is too


low
Check the voltage of solar
Vbus low Undervoltage Illumination
array
intensity is too
weak
The load of water Replace small-power water
pump is too large pump load
In cover Current
The voltage of cell Check the voltage of solar
Dec over Current
Overcurrent array is too low array
con over Current
The motor wiring Shorten the wiring between
is too long inverter and motor
Water pump is Decrease maximum operation
Overload Tel Load is too large
overload frequency

Inverter is The inverter load is Decrease power grade of water


Overload VVVF
overload too large pump

32
Operation Instruction of BSSeries Solar Pumping Inverter Operation Control

Output short circuit


Module Check wiring Seek services
IGBT shortcut or grounding
overcurrent from manufacturer
Module damage
Air flue is blocked
Module is
Environment Clean air flue or improve
Inv Overtemp over-temperatur
temperature is too ventilation
e
high
Output default Equipment or Seek services from
Scarce Phase Out
phase circuit damage manufacturer
The output line
Grounding
Shortcut GND 1 may be connected
short circuit
with ground
Current Seek services from
Curr test Fault
detection failure manufacturer
Water pump’s Check water level. Check
Water pump connection wires whether the water pump wiring
Lack load conducts are all open circuit. condition and water pump
“dry-operation” Water pump does power meet the requirements of
not match inverter. inverter capacity
Water shortage
warning. If water is
No Water provided, it can
Water shortage
recover
automatically
When water level
decreases. It can
Water Full
Water full recover
automatically

Communication Reset Seek services from


Com Fault Device or circuit
failure manufacturer
damage

Warning: before resetting, completely find out failure reasons and eliminate the reasons. If it

fails to reset or suffers failure again, find out the reasons. The continuous resetting will damage
inverter.

33
Chapter V Maintenance

5.1 Daily Inspection and Maintenance


Affected by environment temperature, humidity, vibration, and inverter internal component
aging, the inverter may suffer some potential problems during operation. In order to stably operate
the inverter for a long term, conduct periodical inspection once each year.
5.1.1 Requirements of Inspection and Maintenance
1. The inspection shall be conducted by professional technician. When necessary, cut off the
power supply of inverter.
2. Avoid leaving metal components and parts in inverter, or else it may damage the equipment.
3. The inverter has conducted electrical insulation experiment before leaving factory, so the
user needn’t conduct high-voltage insulation test.
4. If you intend to conduct insulation test on inverter, all input and output terminals must be
short circuit reliably. It is forbidden to conduct insulation test on single terminate. Please
use 500V megameter during test.
5. It is forbidden to use megameter to measure control loop.
6. When conducting insulation test on motor, remove the connecting line between motor and
inverter.
5.1.2 Key Points of Inspection and Maintenance
Please use the inverter under the environment recommended in the manual and conduct
inspection and maintenance according to the following table.
Inspection Frequency
Inspection Item Inspection Content Judgment Standard
Daily Periodically
1. Temperature <50°C
1.Temperature and 2. Humidity <90%, without moisture
Operating
√ humidity condensation
Environment
2. Dust and gas 3. No peculiar smell. No combustible or
explosive gas
1. Installation 1. The ventilation of installation
√ Cooling System environment environment is good
2. Radiator 2. The air flue of radiator is not blocked
1. Vibration, temperature 1. Vibration is stable and shell
rise temperature rise is normal
√ Inverter Body
2. Noise 2. No abnormal noise or peculiar smell
3. Wire, terminal 3. Tighten the screw

1. Vibration, temperature 1. Operate stably. Temperature is normal.


√ Motor
rise 2. No abnormal noise
2. Noise
Input and Output 1. Input Voltage 1. Input voltage is in specified scope

Parameter 2. Output Current 2. Output current is under rated value

34
5.2 Inspection and Replacement of Quick-wear Parts
5.2.1 Filter Capacitor
The pulsating current of main loop will affect the performance of filter capacitor of aluminium
electrolysis. The affected degree and environment temperature are related to service environment.
Under normal conditions, the inverter shall change electrolytic capacitor once every 10 years. When
electrolyte of electrolytic capacitor leaks, safety valve emits, or capacitance expands, replace it
immediately.
5.2.2 Fax cooling
In BS series pumping inverter, the inverter above BS-22K has cooling fan inside. The service
life of cooling fan is about 15000 hours. If fan has abnormal nose or generates vibration, replace it
immediately.

5.3 Storage and Maintenance


5.3.1 Storage
After purchasing inverter, if you do not use it temporarily or decide to store it for a long time,
pay attention to the following items:
1. Avoid putting inverter on the places in which temperature is high, air is humid, or places
where there is vibration or metal dust. Guarantee good ventilation.
2. If the inverter is not used for a long term, the internal filter capacitor characteristic will
decrease. Power on twice every two years to recover the characteristics of filter capacitor.
At the same time, check the functions of inverter. During power-on, gradually increase the
voltage through DC power supply. The power-on time shall not be less than 5 hours.
5.3.2 Maintenance
The warranty period of inverter is 2 years (since production date). During warranty period, if
inverter suffers failure or damage under normal conditions, our company provides maintenance
service free of charge. After warranty period, our company also provides paid maintenance services.
During warranty period, if the failure is caused due to the following reasons, some
maintenance fees will be charged.
1. Failure caused by violation of operation manual or standards;
2. Without authorization, user repairs and transforms the inverter.
3. Failure caused by improper storage;
4. Use inverter for abnormal functions;
5. Failure caused by fire disaster, salt corrosion, gas corrosion, earthquake, windstorm,
flood, lightning, abnormal voltage, or other force majeure.

Notice: the warranty scope only refers to inverter body.

35
Quality Assurance
Warranty Policy:
Warranty period: Our company provides series solar pumping inverter with warranty period
of 24 months. The systematic components provided by our company have 12-month warranty
period.
Starting date of warranty period: the date when user gets goods from our dealer.
Warranty proof: product series number and local dealer’s shipment invoice.
Notice: if client does not provide shipment invoice and other documents, our company will use
the date which is 2 months after delivery date, as starting date of warranty period.
Scope: during warranty period, the scope and responsibility of any damage shall be appraised
by dealer and our company.
Warranty principle:
In order to provide our company final users with better services, all the dealers authorized
shall reply user’s warranty request. During warranty period, the dealer will replace all defective
products and parts in aspects of design and production.
(1) Warranty card is not sent to dealer or our company.
(2) Product change, design alteration, or component replacement is not approved by our
company.
(3) Alter, change or try to repair it. The serial number is wiped out or does not has our
company technician’s seal.
(4) Wrong installation and debugging
(5) Does not abide by proper safety regulation (CQC standards, etc.)
(6) The product is improperly stored and damaged by final user.
(7) Transportation damage. During transportation, the paint is scratched. During unloading, if
enough evidence is available, apply in insurance company as soon as possible.
(8) Fail to abide by user’s manual, installation guidance, and maintenance regulation.
(9) Incorrect use or improper operation
(10) Shortage of ventilating device
(11) The product maintenance procedure does not abide by or implement an acceptable
standard.
(12) Force majeure (such as lightning, over-voltage, thunderstorm, fire disaster)

36
If claim exceeds the power quoted in warranty principle,our company shall not undertake legal
responsibilities, including the following conditions: claim compensation due to direct or indirect
damaged caused by defective equipment; claim compensation due to the damage caused by removal
and installation; profit loss not specified in our company warranty scope.
Warranty and Claim Procedure:
Please send a simple failure description report to our company local dealer. If we agree to
replace, we will issue an equivalent replacement device according to model and year length. The
rest warranty rights will be transferred to replacing equipment. Under such condition, as your power
has been filed in our company, you will not receive a new certification. The substitute goods will be
delivered within 2 working days. The defective equipment is to use the transportation packaging to
transport to dealer. If on-site re-installation is necessary, the end-user shall consult with dealer in
advance. All maintenance services during warranty period are free of charge.

37
Warranty Card
Contact
Client Name
Person
Client Address Contact Tel.
Product Procurement
Specification Date
Warranty
Date
Equipment Code (since
production
date)
Distribution Unit
(Seal)

Packing List

(1) Main engine quantity: One set

(2) Instruction book (including warranty card) quantity: one

(3) Patch plug of positive pole of solar cell array quantity: one

(4) Patch plug of negative pole of solar cell array quantity: one

(5) Water level sensor quantity: one (optional)

You might also like