The ARIO Series document describes Slim Remote I/O products including couplers and modules for industrial Ethernet and fieldbus communication. The couplers support various protocols like EtherCAT, CC-Link, ProfiNet, etc. and allow connection of up to 64 input/output modules. The modules include digital and analog input/output types. The system offers hot-swap capability, push-in wiring, and device management software for configuration and monitoring.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
126 views7 pages

ARIO EN Cat 20190430 W

The ARIO Series document describes Slim Remote I/O products including couplers and modules for industrial Ethernet and fieldbus communication. The couplers support various protocols like EtherCAT, CC-Link, ProfiNet, etc. and allow connection of up to 64 input/output modules. The modules include digital and analog input/output types. The system offers hot-swap capability, push-in wiring, and device management software for configuration and monitoring.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

ARIO Series

Slim Remote I/O


Features
I/O supported based on industrial Ethernet /
Fieldbus serial communication for Smart Factory
Sequential multiple I/O distribution control via
PLC, Industrial PC, etc.
Coupler: Supports a total of 8 different
communications
EtherCAT, CC-Link, ProfiNet, ProfiBus, Ethernet/
IP, DeviceNet, Modbus TCP compatible, Modbus
RTU compatible
Modules: Various Input / Output Modules, Power Modules
- Remote Bus/ I/O power, Digital input/output (4/8CH),
Analog input/output (2/4CH)
- Up to 64 modules can be extended (depending on communication)
Hot-swap function
: Maintenance and setting can be restored automatically by replacing terminal and body during operation
Push-in connection method: Easy wire connection without tools helps reducing workload
Expanded user convenience with DAQMaster, a device integration management program
- Module setting, real time control and monitoring / diagnosis of input / output signal (except ARIO-C-PN/PB)
- Product selection and placement through virtual mode, offering recommended sorting
Please read “Safety Considerations”
in the instruction manual before using.

▣ Models
● Coupler
Model ARIO-C-EC ARIO-C-CL ARIO-C-PN ARIO-C-PB ARIO-C-EI ARIO-C-DN ARIO-C-MT ARIO-C-MR
ModbusTCP ModbusRTU
Coupler type EtherCAT CC-Link ProfiNet ProfiBus Ethernet/IP DeviceNet
compatible compatible

● Digital Input/Output Module ● Analog Input/Output Module


Type Digital input module Digital output module Type Analog input module Analog output module
ARIO-S- ARIO-S- ARIO-S- ARIO-S- ARIO-S- ARIO-S- ARIO-S- ARIO-S-
4CH 2 CH
DI04N DI04P DO04N DO04P AI02V1 AI02C1 AO02V1 AO02C1
Model Model
ARIO-S- ARIO-S- ARIO-S- ARIO-S- ARIO-S- ARIO-S- ARIO-S- ARIO-S-
8CH 4 CH
DI08N DI08P DO08N DO08P AI04V1 AI04C1 AO04V1 AO04C1
I/O common NPN PNP NPN PNP Voltage Current Voltage Current
I/O method
input input output output
● Power Module
Model ARIO-P-B ARIO-P-F1 ARIO-P-F2 ARIO-P-T1 ARIO-P-T2
Slim Remote Slim Remote
Power module
ABUS power I/O power
No. I/O supply 24V 6 2 8 4
-
power 0V 2 6 4 8

Comprehensive Device Management Program (DAQMaster)


●●DAQMaster is comprehensive device management program. It is available for parameter setting, monitoring.
●●Visit our website (www.autonics.com) to download user manual and comprehensive device management program.
< Computer specification for using software > < DAQMaster screen >
Item Minimum requirements
System IBM PC compatible computer with Intel Pentium Ⅲ or above
Operating system Microsoft Windows 98/NT/XP/Vista/7/8/10
Memory 256MB or more
Hard disk More than 1GB of free hard disk space
VGA 1024×768 or higher resolution display
Others RS-232 serial port (9-pin), USB port

X-8
Slim Remote I/O

Manuals
SENSORS

CONTROLLERS

1. Instruction
MOTION DEVICES
manual

SOFTWARE

1. Coupler 2. Module 3.End module


2. Coupler manual 3. Module manual
1. Instruction manual
It describes an overview of Remote I/O, definitions of terms, installation environment, mouting/ removing method, wiring and (J)
Temperature
troubleshooting. Controllers

2. Coupler manual (K)


It describes the overview, specification, demensions, memory map and troubleshooting of each communication. SSRs

3. Module manual (L)


It describes the specification, demensions, and connections of each module. Power
Controllers

Coupler (M)
Counters

Specifications
(N)
Timers
Model ARIO-C-EC ARIO-C-CL ARIO-C-PN ARIO-C-PB ARIO-C-EI ARIO-C-DN ARIO-C-MT ARIO-C-MR
ModbusTCP ModbusRTU
Coupler type EtherCAT CC-Link ProfiNet ProfiBus Ethernet/IP DeviceNet (O)
compatible compatible Digital
Panel Meters
ABUS
(external 24VDCᜡ, max. 400mA (max. 9.6W, coupler+module, max. 200mA/CH, 2CH/COM)
Power consump.) (P)
supply Indicators
※1 ABUS
5VDCᜡ, max. 960mA (max. 4.8W, module)
(internal supply)
I/O 24VDCᜡ, max. 4,000mA (max. 96W, max. 2,000mA/CH, 2CH/COM) (Q)
Converters
Power
Coupler 24VDCᜡ standby/run: 200mA, max. load: 400mA (coupler max. load)
consumption
(R)
Comm. speed 100Mbps 10Mbps 100Mbps 12Mbps 10/100Mbps 500kbps 10/100Mbps 115.2kbps Digital
Display Units
※2 Input 512 byte 256 byte 512 byte 244 byte 504 byte 255 byte 512 byte 256 byte
Memory
Output 512 byte 256 byte 512 byte 244 byte 504 byte 255 byte 512 byte 256 byte (S)
Max. connections for Sensor
※2 64 units 32 units 64 units 32 units 64 units 32 units 64 units 32 units Controllers
modules
RJ45 5-pin PCB RJ45 9-pin D SUB RJ45 5-pin PCB RJ45 5-pin PCB (T)
Comm. connector Switching
connectors: 2 connector connectors: 2 connector connectors: 2 connector connectors: 2 connector Mode Power
Supplies
Installation method DIN rail mounting
Setting and monitoring PC connection with USB 2.0 Micro type connector (comprehensive device management program, DAQMaster) (U)
Insulation resistance Over 100MΩ (at 500VDCᜡ megger) Recorders

Environ- Ambient temp. -10 to 55℃, storage: -25 to 70℃


ment Ambient humi. 35 to 85%RH, storage: 35 to 85%RH (V)
※3 HMIs
Protection structure IP20 (IEC standards)
Material Terminal: polyamide6, Body: modified polyphenylene oxide, Base: polyamide6, polyoxymethylene
(W)
Approval Panel PC
※4
Weight Approx. 265g (approx. 165g)
※1. It is for including power/special modules and excluding coupler/end modules. In case of one coupler module connecting, the ARIO (X)
Field Network
digital module is available to connect up to 8 units and the ARIO analog module is available to connect up to 4 units. For connecting the Devices
modules, consider power consumption of the sensors and drivers connected the ARIO coupler.
※2. If it is over the limit size or connected units, system may be error.
※3. Autonics test standard
※4. The weight includes packaging. The weight in parenthesis is for unit only.
※Environment resistance is rated at no freezing or condensation.

X-9
ARIO Series

Dimensions
● Coupler ● End module
5 33
Model A size
34
A

ARIO-C-
39
EC/EI/PN/MT
ARIO-C-
36.2
DN/CL/MR
ARIO-C-PB 38.2

98.4
52.4
50 70
100

Terminal Body Base

Unit Description
※ It may be different depending on the coupler model.

1. C
 ommunication connector
ARIO-C- ARIO-C-
4 ARIO-C-PB
1 EC/PN/EI/MT CL/DN/MR
6
5-Pin PCB
RJ-45: 2 DSUB-9Pin
connector

2. Communication setting switch


5 ARIO-C-EC ARIO-C-CL/DN The others
Decimal rotary
Hexagonal rotary
switches: 3
3 None switches: 2
(Comm. speed,
(address (×10, ×1))
2 address (×10, ×1))

3. S etting connector (USB 2.0 type Micro B)


4. Indicators for power and comm. status
6 5. Power terminal block
6. ABUS comm. connector

X-10
Slim Remote I/O

Digital Input/Output Module


Specifications SENSORS

Type Digital input module Digital output module


CONTROLLERS
4CH ARIO-S-DI04N ARIO-S-DI04P ARIO-S-DO04N ARIO-S-DO04P
Model
8CH ARIO-S-DI08N ARIO-S-DI08P ARIO-S-DO08N ARIO-S-DO08P
I/O common NPN PNP NPN PNP MOTION DEVICES

Turn ON: min. 7VDCᜡ


Input voltage -
Turn OFF: max. 0.4VDCᜡ
SOFTWARE
Output leakage voltage - Max. 1.2VDCᜡ
※1
I/O signal level 24VDCᜡ±10%
I/O current 4CH Max. 6mA/CH, 4CH/COM
-
consumption 8CH Max. 6mA/CH, 8CH/COM
4CH Max. 500mA/CH, 4CH/COM
Rated output current -
8CH Max. 500mA/CH, 8CH/COM
On delay time Max. 0.5ms
(J)
Off delay time Max. 1.5ms Temperature
Controllers
Power consump. (ABUS) 5VDCᜡ, max. 100mA (max. 0.5W)
Installation method DIN rail mounting (K)
SSRs
Insulation resistance 100MΩ (at 500VDCᜡ megger) I/O to inner circuit: photocoupler insulated, between CHs: non-insulated
Ambient temp. 10 to 55℃, storage: -25 to 70℃
Environment (L)
Ambient humi. 35 to 85%RH, storage: 35 to 85%RH Power
※2
Controllers
Protection structure IP20 (IEC standards)
Material Terminal: polyamide6, Body: modified polyphenylene oxide, Base: polyamide6, polyoxymethylene (M)
Counters
Approval
※3
Weight Approx. 108g (approx. 75g)
(N)
※1. Power supply is from ARIO-P Series. Normal operation is available when I/O power voltage is supplied. Timers
※2. Autonics test standard
※3. The weight includes packaging. The weight in parenthesis is for unit only.
(O)
※Environment resistance is rated at no freezing or condensation. Digital
Panel Meters
※In case of one coupler module connecting, the ARIO digital module is available to connect up to 8 units. For connecting the modules,
consider power consumption of the sensors and drivers connected the ARIO coupler.
(P)
Indicators
Dimensions
(Q)
14.4 Converters

12 70
(R)
Digital
Display Units

Status (S)
indicator Sensor
Controllers

(T)
Switching
Mode Power
Supplies
100

(U)
Recorders

(V)
HMIs

(W)
Panel PC

Terminal Body Base


(X)
Field Network
Devices

X-11
ARIO Series

Analog Input/Output Module


Specifications
Type Analog input module Analog output module
2CH ARIO-S-AI02V1 ARIO-S-AI02C1 ARIO-S-AO02V1 ARIO-S-AO02C1
Model
4CH ARIO-S-AI04V1 ARIO-S-AI04C1 ARIO-S-AO04V1 ARIO-S-AO04C1
I/O method Voltage input Current input Voltage output Current output
I/O range -10 to 10VDCᜡ 0 to 20mA -10 to 10VDCᜡ 0 to 20mA
Room temp. ±0.3% F.S.
Accuracy
Out of room temp. ±0.6% F.S.
Input impedance Min. 1MΩ Max. 250Ω -
Load resistance - Min. 5kΩ Max. 350Ω
Status indicator ON conditions Below -1V or over 1V Over 1mA Below -1V or over 1V Over 1mA
Resolution 12bit
5VDCᜡ, max. 100mA,
ABUS 5VDCᜡ, max. 180mA (max. 0.9W)
(max. 0.5W)
Power consumption
24VDCᜡ, max. 60mA,
I/O 24VDCᜡ, max. 15mA (max. 0.36W)
(max. 1.44W)
Installation method DIN rail mounting
100MΩ (at 500VDCᜡ megger) I/O to inner circuit: photocoupler insulated, between channels: non-
Insulation resistance
insulated
Environ- Ambient temp. -10 to 55℃, storage: -25 to 70℃
ment Ambient humi. 35 to 85%RH, storage: 35 to 85%RH
※1
Protection structure IP20 (IEC standards)
Material Terminal: polyamide6, Body: modified polyphenylene oxide, Base: polyamide6, polyoxymethylene
Approval
※2
Weight Approx. 108g (approx. 75g)
※1. Autonics test standard
※2. The weight includes packaging. The weight in parenthesis is for unit only.
※Environment resistance is rated at no freezing or condensation.
※Power supply is from ARIO-P Series. Normal operation is available when I/O power voltage is supplied. In case of one coupler module
connecting, the ARIO analog module is available to connect up to 4 units. For connecting the modules, consider power consumption of the
sensors and drivers connected the ARIO coupler.

Dimensions
14.4
12 70

Status
indicator
100

Terminal Body Base

X-12
Slim Remote I/O

Power Module
Specifications SENSORS

● Slim Remote ABUS Power Module


CONTROLLERS
Model ARIO-P-B
ABUS
24VDCᜡ, max. 320mA (max. 7.5W, max. 160mA/CH, 2CH/COM)
Power (external consumption)
MOTION DEVICES
supply ABUS
5VDCᜡ, max. 1,500mA (max. 7.5W)
(internal supply)
Installation method DIN rail mounting SOFTWARE

Insulation resistance 100MΩ(at 500VDCᜡ megger)


Environ- Ambient temp. -10 to 55℃, storage: -25 to 70℃
ment Ambient humi. 35 to 85%RH, storage: 35 to 85%RH
※1
Protection structure IP20 (IEC standards)
Material Terminal: polyamide6, Body: modified polyphenylene oxide, Base: polyamide6, polyoxymethylene
Approval
※2
Weight Approx. 108g (approx. 75g) (J)
Temperature
Controllers
※The ARIO digital module is available to connect up to 8 units and the ARIO analog module is available to connect up to 4 units.
● Slim Remote I/O Power Module
(K)
SSRs
Model ARIO-P-F1 ARIO-P-F2 ARIO-P-T1 ARIO-P-T2
Voltage 24VDCᜡ±10% (max. 48W) -
Input (L)
Max. current Max. 2,000mA/CH, 2CH/COM - Power
Controllers
Voltage 24VDCᜡ±10% (max. 48W) 24VDCᜡ±10% (max. 48W)
Output
Max. current Max. 2,000mA/CH, 6CH/COM Max. 2,000mA/CH,8CH/COM (M)
Counters
24V 6 2 8 4
No. of I/O supply power
0V 2 6 4 8
(N)
Installation method DIN rail mounting Timers

Insulation resistance 100MΩ(at 500VDCᜡ megger)


(O)
Environ- Ambient temp. -10 to 55℃, storage: -25 to 70℃ Digital
Panel Meters
ment Ambient humi. 35 to 85%RH, storage: 35 to 85%RH
Protection structure※1 IP20 (IEC standards)
(P)
Material Terminal: polyamide6, Body: modified polyphenylene oxide, Base: polyamide6, polyoxymethylene Indicators

Approval
※2 (Q)
Weight Approx. 108g (approx. 75g) Converters

※1. Autonics test standard


※2.The weight includes packaging. The weight in parenthesis is for unit only. (R)
※Environment resistance is rated at no freezing or condensation. Digital
Display Units
※For connecting the modules, consider power consumption of the sensors and drivers connected the ARIO power module.

Dimensions
(S)
Sensor
Controllers

14.4
(T)
Switching
12 70 Mode Power
Supplies

Power (U)
Recorders
indicator

(V)
HMIs
100

(W)
Panel PC

(X)
Field Network
Devices

Terminal Body Base

X-13
ARIO Series

General Information
▣ Hot-swap

● Terminal
: Part of the input and output signal comes out of the
product

● Body
: Part of the input and output signal controled of the
product

● Base
: Part of the communication (Bus) and power
connection between coupler and modules

During the operation of the system, the hardware part (terminal and body) can be replaced and maintenance and setting
can be restored automatically. (All modules except coupler and end module support Hot-swap.)
1) Terminal / body can be replaced during operation without disassembling the terminal signal line
: Even if the terminal / body of the abnormal I/O module is disconnected from the connected system (Coupler, I/O
Module configuration), the other I/O operates normally.
2) Diagnostic function: Check removal or connection for terminal or body of abnormal module
3) Normal operation of the rearranged module even after removing the body of the module
4) Automatic restoration of existing settings when replacing body through backup function of internal bus communication

▣ Connecting & Removing Wires ①


Connecting
Push the wire connected with the crimp terminal towards direction ①
to complete the connection. ③

Removing
1) Press and hold the catch above the terminal in direction ②
with a non-conductive flat head screwdriver (width max. 3mm).
2) Pull and remove the wire towards direction ③.

※Use the UL certified End Sleeve (Ferrule Terminal) crimp terminals and wire.
Use the copper-conductor wire with the temperature class 60℃.
a
a b c Certified spec.
Range 8 to 12mm 0.6 to 1.3mm AWG22-16
b c Max. 3mm
Recommended 10mm 1mm AWG18
<Crimp terminal>

▣ Caution during Use


1. Follow instructions in 'Cautions during Use'. Otherwise, It may cause unexpected accidents.
2. ABUS power and I/O power should be insulated by the individually insulated power device.
3. Power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
4. Use the rated standard cables and connectors. Do not apply excessive power when connecting or disconnecting
the connectors of the product.
5. Keep away from high voltage lines or power lines to prevent inductive noise. In case installing power line and input
signal line closely, use line filter or varistor at power line and shielded wire at input signal line.
For stable operation, use shield wire and ferrite core, when wiring communication wire, power wire, or signal wire.
Do not use near the equipment which generates strong magnetic force or high frequency noise.
6. Do not touch the module communication connector part of the base.
7. Do not connect, or remove the base while connected to a power source. For removing the terminal, body or base,
do not operate units for a long time without it
8. This unit may be used in the following environments.
①Indoors ②Altitude max. 2,000m
③Pollution degree 2 ④Installation category II)

X-14