0% found this document useful (0 votes)
2K views45 pages

Stopping

stopping

Uploaded by

a
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views45 pages

Stopping

stopping

Uploaded by

a
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 45

Table Of Contents

UL Listings
HW-D-0155 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
HW-D-0218 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
HW-D-0259 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

CFS-SP WB Water-based acrylic sealant spray


Product Data Sheet for CFS-SP WB Firestop Joint Spray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
UL Certificate of Compliance for CFS-SP WB Firestop Joint Spray . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Safety Data Sheet (SDS) for CFS-SP WB Firestop Joint Spray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
LEED Information for CFS-SP WB Firestop Joint Spray . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

CP 606 Firestop acrylic sealant


Product Data Sheet for CP 606 Flexible Firestop Sealant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
UL Certificate of Compliance for CP 606 Flexible Firestop Sealant . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Safety Data Sheet (SDS) for CP 606 Flexible Firestop Sealant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
LEED Information for CP 606 Flexible Firestop Sealant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

CP 767
Product Data Sheet for CP 767 and CP 777 Speed Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
UL Certificate of Compliance for CP 767 and CP 777 Speed Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Material Information Statement for Firestop Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
LEED Information for CP 767 Speed Strips and CP 777 Speed Plugs . . . . . . . . . . . . . . . . . . . . . . . . 33

CP 777
Product Data Sheet for CP 767 and CP 777 Speed Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
UL Certificate of Compliance for CP 767 and CP 777 Speed Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Material Information Statement for Firestop Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
LEED Information for CP 767 Speed Strips and CP 777 Speed Plugs . . . . . . . . . . . . . . . . . . . . . . . . 37

Mineral wool
Product Data Sheet for Mineral Wool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
UL Certificate of Compliance for Mineral Wool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Material Information Statement for Firestop Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
LEED Information for Mineral Wool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
S IFI

HWD 0155
AS
System No. HW-D-0155
CL

ED
C US Assembly Rating — 2 Hr
Classified by
Underwriters Laboratories, Inc.
Nominal Joint Width—3/4 In.
to UL 2079 and CAN/ULC-S115 L Rating At Ambient — Less Than 1 CFM/Lin Ft
L Rating At 400°F — Less Than 1 CFM/Lin Ft
Class II Movement Capabilities—17% Compression Or Extension

1B 1A 1B
A 3C

1A
3A

A
2
SECTION A-A

1. Floor Assembly — The fire-rated fluted steel floor unit/concrete floor assembly shall be constructed of the materials and in the manner described
in the individual D900 Floor-Ceiling Design in the Fire Resistance Directory and shall include the following construction features:
A. Steel Floor and Form Units* — Max 2 in. (51 mm) deep galv steel fluted floor units.
B. Concrete — Min 2-1/2 in. (64 mm) thick reinforced concrete, as measured from the top plane of the floor units.
1A. Roof Assembly — (Not Shown) — As an alternate to the floor assembly, a fire rated fluted steel deck roof assembly may be used. The roof
assembly shall be constructed of the materials and in the manner described in the individual P900 Series Roof-Ceiling Design in the UL Fire
Resistance Directory. The hourly rating of the roof assembly shall be equal to or greater than the hourly rating of the wall assembly. The roof
assembly shall include the following construction features:
A. Steel Roof Deck — Max 3 in. (76 mm) deep galv steel fluted roof deck.
B. Roof Insulation — Min 2-1/4 in. (57 mm) thick poured insulating concrete, as measured from the top plane of the floor units.
2. Wall Assembly — Min 5 in. (127 mm) thick steel reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. Wall may
also be constructed of an UL Classified Concrete Blocks*.
See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufactures.

Reproduced by HILTI, Inc. Courtesy of


Underwriters Laboratories, Inc.
June 26, 2008
Page: 1 of 2
S IFI

HWD 0155
AS
System No. HW-D-0155
CL

ED
C US Assembly Rating — 2 Hr
Classified by
Underwriters Laboratories, Inc.
Nominal Joint Width—3/4 In.
to UL 2079 and CAN/ULC-S115 L Rating At Ambient — Less Than 1 CFM/Lin Ft
L Rating At 400°F — Less Than 1 CFM/Lin Ft
Class II Movement Capabilities—17% Compression Or Extension
See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufactures.
3. Joint System — Max separation between bottom of floor or roof and top of wall is 3/4 in. (19 mm). The joint system is designed to accommodate a
max 17 percent compression or extension from its installed width. The joint system consists of a forming material and a fill material between the
top of the wall and the bottom of the floor or roof, as follows:
A. Forming Material* — Nom 4 pcf (64 kg/m3) density mineral wool batt insulation cut approx 20 percent wider than the flutes, with a length
approx equal to the overall thickness of the wall. Pieces stacked as needed and then compressed 20 percent in thickness and inserted into
the flutes of the steel deck. The mineral wool batt insulation shall be recessed 1/4 in. (6 mm) from wall surfaces. Additional nom 4 pcf (64
kg/m3) mineral wool batt insulation shall be cut into strips to fill the gap between the top of the wall and bottom of the steel deck. The width of
the strips shall be equal to the total thickness of the wall less 1/2 in. The strips of mineral wool are compressed 50 percent in thickness and
firmly packed into the gap between the top of the wall and bottom of the steel deck, recessed 1/4 in. (6 mm) ffrom wall surfaces.
FIBREX INSULATIONS INC — FBX Safing Insulation
A1. Forming Material*—Plugs — (Optional-Not Shown) Performed mineral wool plugs, formed to the shape of the fluted floor units, friction fit to
completely fill the flutes. The plugs shall be recessed 1/4 in. (6 mm) from both wall surfaces. Additional forming material, described in Item 3A,
to be used in conjunction with the plugs to fill the gap between the top of the wall and bottom of steel floor units.
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP777 Speed Plugs
B. Fill, Void or Cavity Material* - Sealant — Min 1/4 in. (6 mm) thickness of fill material installed on each side of the wall in the flutes of the steel
deck between the top of the wall and the bottom of the steel deck, flush with each surface of the wall.
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP606 Flexible Firestop Sealant
*Bearing the UL Classification Mark

Reproduced by HILTI, Inc. Courtesy of


Underwriters Laboratories, Inc.
June 26, 2008
Page: 2 of 2
HWD 0218
S IFI
AS
CL
System No. HW-D-0218

ED
C US
Classified by ANSI/UL2079 CAN/ULC S115
Underwriters Laboratories, Inc.
to UL 1479 and CAN/ULC-S115 Assembly Ratings — 1 and 2 Hr (See Item 2) F Ratings — 1 and 2 Hr (See Item 2)
Nominal Joint Width - 1-1/2 In. FT Ratings — 1 and 2 Hr (See Item 2)
Class II Movement Capabilities — 25% Compression or
FH Ratings — 1 and 2 Hr (See Item 2)
Extension
L Rating At Ambient — Less Than 1 CFM/lin ft FTH Ratings — 1 and 2 Hr (See Item 2)
L Rating At 400 F — Less Than 1 CFM/lin ft Nominal Joint Width - 1-1/2 In.
Class II Movement Capabilities — 25% Compression or
Extension
L Rating At Ambient — Less Than 1 CFM/lin ft
L Rating At 400 F — Less Than 1 CFM/lin ft

1A 1B 1A 1B
A

1E
2A
3A
1C

1E 1C 3B 1D
3A
2B 2C
3B A 2C 2B SECTION A-A

1. Floor Assembly — The fire-rated fluted steel floor unit/concrete floor assembly shall be constructed of the materials and in the manner
described in the individual D700 or D900 Series Floor-Ceiling Design in the Fire Resistance Directory and shall include the following
construction features:
A. Steel Floor and Form Units* — Max 3 in. (76 mm) deep galv steel fluted floor units.
B. Concrete — Min 2-1/2 in. (64 mm) thick reinforced concrete, as measured from the top plane of the floor units.
C. Structural Steel Support (Optional) - Steel beam or open-web steel joist, as specified in the individual D700 or D900 Series Floor-Ceiling
Design, used to support steel floor units. Structural steel support oriented perpendicular to wall assembly. — Steel beam or open-web steel
joist, as specified in the individual D700 or D900 Series Floor-Ceiling Design, used to support steel floor units. Structural steel support
oriented perpendicular to wall assembly.
D. Steel Lath — Where open-web steel joists pass through the fire rated wall, 3/8 in. diamond mesh expanded steel lath having a nom weight
of 1.7 to 3.4 lb per sq yd (0.9 to 1.8 kg/m2) shall be secured to one side of each joist with steel tie wire and the lath shall be fully covered
with no min thickness requirement.

Reproduced by HILTI, Inc. Courtesy of


Underwriters Laboratories, Inc.
September 26, 2019
Hilti Firestop Systems Page: 1 of 3
HWD 0218
System No. HW-D-0218

E. Spray-Applied Fire Resistive Material* — After the installation of the ceiling runner, (Item 2A, 2A1 or 2A2) steel floor units to be sprayed
with the thickness of material specified in the individual D700 Series Design or the structural steel supports to be sprayed in accordance
with the specifications in the individual D900 Series Design. Material is to be excluded from the steel floor units, directly above the gypsum
board and from the flanges of the ceiling runners.
ISOLATEK INTERNATIONAL — Type 300
GCP APPLIED TECHNOLOGIES INC — Types MK-6/HY or MK-10HB
1A. Roof Assembly — (Not Shown) — As an alternate to the floor assembly, a fire rated fluted steel deck roof assembly may be used. The
roof assembly shall be constructed of the materials and in the manner described in the individual P700 or P900 Series Roof-Ceiling Design
in the UL Fire Resistance Directory. The hourly rating of the roof assembly shall be equal to or greater than the hourly rating of the wall
assembly. The roof assembly shall include the following construction features as applicable:
A. Steel Roof Deck — Max 3 in. (76 mm) deep galv steel fluted roof deck.
B. Roof Insulation — Min 2-1/4 in. (57 mm) thick poured insulating concrete, as measured from the top plane of the steel roof deck.
C. Structural Steel Support — (Optional) - Steel beam or open-web steel joist, as specified in the individual P700 or P900 Series Roof-Ceiling
Design, used to support steel roof deck. Structural steel support oriented perpendicular to wall assembly. Steel beam or open-web steel
joist, as specified in the individual P700 or P900 Series Roof-Ceiling Design, used to support steel roof deck. Structural steel support
oriented perpendicular to wall assembly.
D. Steel Lath — Where open-web steel joists pass through the fire rated wall, 3/8 in. diamond mesh expanded steel lath having a nom weight
of 1.7 to 3.4 lb per sq yd (0.9 to 1.8 kg/m2) shall be secured to one side of each joist with steel tie wire and the lath shall be fully covered
with no min thickness requirement.
E. Spray-Applied Fire Resistive Material* — After the installation of the ceiling runner, (Item 2A, 2A1 or 2A2) steel roof deck to be sprayed
with the thickness of material specified in the individual P700 Series Design or the structural steel supports to be sprayed in accordance
with the specifications in the individual P700 or P900 Series Design. Material is to be excluded from the steel roof deck, directly above the
gypsum board and from the flanges of the ceiling runners.
ISOLATEK INTERNATIONAL — Type 300
GCP APPLIED TECHNOLOGIES INC — Types MK-6/HY or MK-10HB
2. Wall Assembly* — The 1 or 2 h fire-rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner specified
in the individual U400 or V400 Series Wall and Partition Design in the UL Fire Resistance Directory and shall include the following construction
features:
A. Steel Floor and Ceiling Runners — Floor and ceiling runners of wall assembly shall consist of min No. 25 gauge galv steel channels sized
to accommodate steel studs (Item 2B). Flange height of ceiling runner shall be min 1/4 in. (6 mm) greater than max extended joint width.
Ceiling runner centered beneath and parallel with valley of steel floor units (Item 1A). Ceiling runner secured to steel floor units with
masonry anchors, steel fasteners or welds spaced max 24 in. (610 mm) OC. A clearance of 1-1/2 in. (38 mm) shall be maintained between
the ceiling runner and the spray-applied fire resistive material on the structural steel support members.
A1 Light Gauge Framing*-Slotted Ceiling Runner — As an alternate to the ceiling runner in Item 2A, slotted ceiling runner to consist of galv
steel channel with slotted flanges sized to accommodate steel studs (Item 2B). Slotted ceiling runner installed parallel to direction of fluted
steel deck, centered beneath valley, prior to the application of spray-applied fire resistive material, and secured with steel masonry anchors,
steel fasteners or welds spaced max 24 in. (610 mm) OC.
BRADY CONSTRUCTION INNOVATIONS INC, DBA SLIPTRACK SYSTEMS — SLP-TRK, SLPTRK325
CALIFORNIA EXPANDED METAL PRODUCTS CO — CST
CLARKDIETRICH BUILDING SYSTEMS — Types SLT, SLT-H
MARINO/WARE, DIV OF WARE INDUSTRIES INC — Type SLT
RAM SALES L L C — RAM Slotted Track
SCAFCO STEEL STUD MANUFACTURING CO
TELLING INDUSTRIES L L C — True-Action Deflection Track
A2. Light Gauge Framing*-Vertical Deflection Ceiling Runner — As an alternate to the ceiling runners in Item 2A and 2A1, vertical deflection
ceiling runner to consist of galv steel channel with slotted vertical deflection clips mechanically fastened within runner. Slotted clips,
provided with step bushings, for permanent fastening of steel studs. Flanges sized to accommodate steel studs (Item 2B). Vertical
deflection ceiling runner installed parallel to direction of fluted steel deck, centered beneath valley, prior to the application of spray-applied
fire resistive material, and secured with steel masonry anchors, steel fasteners or welds spaced max 24 in. (610 mm) OC.

Reproduced by HILTI, Inc. Courtesy of


Underwriters Laboratories, Inc.
September 26, 2019
Hilti Firestop Systems Page: 2 of 3
HWD 0218
System No. HW-D-0218
A3. Light Gauge Framing*- Notched Ceiling Runner — As an alternate to the ceiling runners in Items 2A through 2A2, notched ceiling
runners to consist of C-shaped galv steel channel with notched return flanges sized to accommodate steel studs (Item 2B). Notched
ceiling runner installed parallel to direction of fluted steel deck, centered beneath valley, prior to the application of spray-applied fire
resistive material, and secured with steel masonry anchors, steel fasteners or welds spaced max 24 in. (610 mm) OC.
OLMAR SUPPLY INC — Type SCR
A4. Light Gauge Framing* — Slotted Ceiling Runner — As an alternate to the ceiling runner in Item 2A through 2A3, ceiling runner to
consist of galv steel channel with slotted flanges sized to accommodate steel studs (Item 2B). Flange height of slotted ceiling runner shall
be 3-1/4 in. (83 mm) with 2 in. (51 mm) deep slots. Slotted ceiling runner installed parallel to direction of fluted steel deck, centered
beneath valley, prior to the application of spray-applied fire resistive material, and secured with steel masonry anchors, steel fasteners or
welds spaced max 24 in. (610 mm) OC.
SCAFCO STEEL STUD MANUFACTURING CO — Slotted Track-Type SDLT
B. Studs — Steel studs to be min 3-5/8 in. (92 mm) wide. Studs cut 1/2 to 3/4 in. (13 to 19 mm) less in length than assembly height with
bottom nesting in, resting on and fastened to the floor runner and with top nesting in ceiling runner without attachment. When slotted
ceiling runner (Item 2A1) is used, steel studs secured to slotted ceiling runner with No. 8 by 1/2 in. (13 mm) long wafer head steel screws
at midheight of slot on each side of wall. When vertical deflection runner (Item 2A2) is used, studs secured to vertical clip through slip
bushing, supplied, with No.8 by 1/2 in. (13 mm) steel screws at midheight of slot of each slot. When slotted ceiling runner (Item 2A4) is
used, steel studs cut in lengths 3/4 to 1-3/4 in. (19 to 44 mm) less than floor to ceiling height and secured to slotted ceiling runner with No.
8 by 1/2 (13 mm) long wafer head steel screws at +/- 3/16 in. (5 mm) of the mid-height of slot on each side of wall. A framed opening shall
be constructed around each steel structural member A min clearance of 1 in. (25 mm) to a max of 4 in. (102 mm) shall be maintained
between the framing and the spray-applied fire resistive material on the two sides of the structural support. The clearance between the
framing and the spray-applied fire resistive material on the bottom of the structural steel support shall be max 2 in. (51 mm). Stud spacing
not to exceed 24 in. (610 mm) OC.
C. Gypsum Board* — 5/8 in. (16 mm) thick, 4 ft (1.2 m) wide with square or tapered edges. The gypsum board type, number of layers an
sheet orientation shall be as specified in the individual U400, V400 or W400 Series Design in the Fire Resistance Directory, except that a
max 1-1/2 in. (38 mm) gap shall be maintained between top of gypsum board and bottom plane of steel floor units and between the top
edge of the gypsum board and the spray applied fire resistive material on the structural steel support. The top row of screws shall be
installed into the studs 1-1/2 to 2 in. (38 to 51 mm) below the bottom of the ceiling runner.
The hourly ratings of the joint system are dependent on the hourly rating of the wall.
3. Joint System — Max separation between bottom of floor units and top of gypsum board at time of installation is 1-1/2 in. (38 mm). Max
separation between spray-applied fire resistive material on bottom of structural support and framed opening in top of wall is 2 in. (51 mm). The
joint system is designed to accommodate a max 25 percent compression or extension from its installed width. The joint system consists of a
forming material and a fill material between the top of the gypsum board and the bottom of the floor, as follows
A. Forming Material* — Nominal 4 in. (102 mm) thick pieces of nominal 4 pcf (64 kg/m3) forming material, sized to be flush with both
surfaces of wall, placed to fully fill the framed opening around the structural steel support. Forming material to be installed with fibers
vertical along the sides of the beam and pieces sized to attain a min compression rate of 25 percent in the thickness direction. Forming
material to be installed with fibers horizontal at the bottom of the beam and pieces sized to attain a min compression rate of 50 percent in
the thickness direction. Additional mineral wool batt insulation cut into strips to fill the gap between top of the gypsum board and bottom of
floor units. Width of the strips shall be equal to the total thickness of the gypsum board. The strips of mineral wool shall be compressed 50
percent in thickness and firmly packed into the gap between the top of gypsum board and bottom of floor units.
INDUSTRIAL INSULATION GROUP L L C — MinWool-1200 Safing
JOHNS MANVILLE — Safing
ROCK WOOL MANUFACTURING CO — Delta Board
ROCKWOOL — SAFE
THERMAFIBER INC — Type SAF
B. Fill, Void or Cavity Material* - Sealant — A min 1/16 in. (1.6 mm) dry thickness (min 1/8 in. or 3.2 mm wet thickness) of fill material
sprayed of troweled on each side of wall to completely cover mineral wool forming material and to overlap min 1/2 in. (13 mm) onto
gypsum board and min 2 in. (51 mm) onto the steel floor units or the spray applied material on the steel floor unit and on the structural
support member on both sides of wall.
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CFS-SP WB Firestop Joint Spray

* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada),
respectively.

Reproduced by HILTI, Inc. Courtesy of


Underwriters Laboratories, Inc.
September 26, 2019
Hilti Firestop Systems Page: 3 of 3
S IFI

HWD0259
AS
CL
System No. HW-D-0259

ED
C US
ANSI/UL2079 CAN/ULC S115
Classified by
Underwriters Laboratories, Inc. Assembly Ratings — 1 and 2 Hr (See Items 1 and 2) F Ratings — 1 and 2 Hr (See Items 1 and 2)
to UL 2079 and CAN/ULC-S115
Nominal Joint Width - 1-1/2 In. FT Ratings — 1 and 2 Hr (See Items 1 and 2)
Class II Movement Capabilities — 50% Compression or
FH Ratings — 1 and 2 Hr (See Items 1 and 2)
Extension
L Rating At Ambient — Less Than 1 CFM/lin ft FTH Ratings — 1 and 2 Hr (See Items 1 and 2)
L Rating At 400 F — Less Than 1 CFM/lin ft Nominal Joint Width - 1-1/2 In.
Class II Movement Capabilities — 50% Compression or
Extension
L Rating At Ambient — Less Than 1 CFM/lin ft
L Rating At 400 F — Less Than 1 CFM/lin ft

1A 1B SECTION A-A
A

1C
1D

3B

3A 2

Reproduced by HILTI, Inc. Courtesy of


Underwriters Laboratories, Inc.
September 26, 2019
Hilti Firestop Systems Page: 1 of 2
HWD0259
System No. HW-D-0259

1. Floor Assembly — The fire-rated fluted steel floor unit/concrete floor assembly shall be constructed of the materials and in the manner described
in the individual Floor-Ceiling Design in the Fire Resistance Directory and shall include the following construction features:
A. Steel Floor and Form Units* — Max 3 in. (76 mm) deep galv steel fluted floor units.
B. Concrete — Min 2-1/2 in. (64 mm) thick reinforced concrete, as measured from the top plane of the floor units.
C. Structural Steel Support — Steel beam, as specified in the individual D700 or D900 Series Floor-Ceiling Design, used to support steel floor
units. Structural steel support centered over and parallel with wall assembly.
D. Spray-Applied Fire Resistive Material* — Steel floor units and structural steel beam to be sprayed with the thickness of material specified in
the individual D700 Series Design or the structural steel supports to be sprayed in accordance with the specifications in the individual D900
Series Design. The flutes of the steel floor units are to be filled with material across the entire top flange of the steel beam. Additional material
shall be applied to the web of the steel beam on each side of the wall. For a 1 hr Assembly Rating, the total thickness of material applied to
each side of the steel beam web shall be min 13/16 in. (21 mm). For a 2 hr Assembly Rating, the total thickness of material applied to each
side of the steel beam web shall be min 1-3/8 in. (35 mm).
GCP APPLIED TECHNOLOGIES INC — Types MK-6-HY or MK-10HB
D1. Spray-Applied Fire Resistive Material* — Steel floor units and structural steel support to be sprayed with the min thickness of material
specified in the individual D700 or D900 Series Design. The flutes of the steel floor units are to be filled with material across the entire top
flange of the steel beam. Additional material shall be applied to the web of the steel beam on each side of the wall. For a 1 hr Assembly
Rating, the total thickness of material applied to each side of the steel beam web shall be min 11/16 in. (18 mm). For a 2 hr Assembly Rating,
the total thickness of material applied to each side of the steel beam web shall be min 1-1/2 in. (38 mm).
ISOLATEK INTERNATIONAL — Type 300
2. Wall Assembly* — The 1 or 2 h fire rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner specified in
the individual U400, V400 or W400 Series Wall and Partition Design in the UL Fire Resistance Directory and shall include the following
construction features:
A. Steel Floor and Ceiling Runners — Floor and ceiling runners of wall assembly shall consist of min No. 25 gauge galv steel channels sized to
accommodate steel studs (Item 2B). Flange height of ceiling runner shall be min 1/4 in. (6 mm) greater than max extended joint width. Ceiling
runner centered beneath and parallel with steel beam (Item 1C). Ceiling runner secured to steel beam through spray-applied fire resistive
material with steel fasteners spaced max 24 in. (610 mm) OC.
A1. Light Gauge Framing* — Slotted Ceiling Runner As an alternate to the ceiling runner in Item 2A, slotted ceiling runner to consist of galv
steel channel with slotted flanges sized to accommodate steel studs (Item 2B). Slotted ceiling runner centered beneath and parallel with steel
beam (Item 1C). Slotted ceiling runner secured to steel beam with steel fasteners, steel fasteners or welds spaced max 24 in. (610 mm) OC.
BRADY CONSTRUCTION INNOVATIONS INC, DBA SLIPTRACK SYSTEMS — SLP-TRK, SLPTRK325
CALIFORNIA EXPANDED METAL PRODUCTS CO — CST
CLARKDIETRICH BUILDING SYSTEMS — Type SLT, SLT-H
MARINO/WARE, DIV OF WARE INDUSTRIES INC — Type SLT
RAM SALES L L C — RAM Slotted Track
SCAFCO STEEL STUD MANUFACTURING CO
TELLING INDUSTRIES L L C — True-Action Deflection Track
A2. Light Gauge Framing* — Vertical Deflection Ceiling Runner As an alternate to the ceiling runners in Item 2A and 2A1, vertical deflection
ceiling runner to consist of galv steel channel with slotted vertical deflection clips mechanically fastened within runner. Slotted clips, provided
with step bushings, for permanent fastening of steel studs. Flanges sized to accommodate steel studs (Item 2B). Vertical deflection ceiling
runner centered beneath and parallel with steel beam (Item 1C). Vertical Deflection ceiling runner secured to steel beam with steel fasteners,
steel fasteners or welds spaced max 24 in. (610 mm) OC.

Reproduced by HILTI, Inc. Courtesy of


Underwriters Laboratories, Inc.
September 26, 2019
Hilti Firestop Systems Page: 2 of 2
HWD0259
System No. HW-D-0259

A3. Light Gauge Framing*- Notched Ceiling Runner — As an alternate to the ceiling runners in Items 2A through 2A2, notched ceiling runners to
consist of C-shaped galv steel channel with notched return flanges sized to accommodate steel studs (Item 2B). Notched ceiling runner
installed perpendicular to direction of fluted steel deck and secured to valleys with steel masonry anchors, steel fasteners or welds spaced
max 24 in. (610 mm) OC.
OLMAR SUPPLY INC — Type SCR
A4. Light Gauge Framing* — Slotted Ceiling Runner — As an alternate to the ceiling runner in Item 2A through 2A3, ceiling runner to consist of
galv steel channel with slotted flanges sized to accommodate steel studs (Item 2B). Flange height of slotted ceiling runner shall be 3-1/4 in.
(83 mm) with 2 in. (51 mm) deep slots. Slotted ceiling runner centered beneath and parallel with steel beam (Item 1C). Slotted ceiling runner
secured to steel beam with steel fasteners or welds spaced max 24 in. (610 mm) OC.
SCAFCO STEEL STUD MANUFACTURING CO — Slotted Track-Type SDLT
B. Studs — Steel studs to be min 3-1/2 in. (89 mm) wide. Studs cut 3/4 in. to 1-1/4 in. (19 to 32 mm) less in length than assembly height with
bottom nesting in, resting on and fastened to the floor runner and with top nesting in ceiling runner without attachment. When slotted ceiling
runner (Item 2A1) is used, steel studs secured to slotted ceiling runner with No. 8 by 1/2 in. (13 mm) long wafer head steel screws at
midheight of slot on each side of wall. When vertical deflection runner (Item 2A2) is used, studs secured to vertical clip through slip bushing,
supplied, with No.8 by 1/2 in. (13 mm) steel screws at mid-height of slot of each slot. Stud spacing not to exceed 24 in. (610 mm) OC. When
slotted ceiling runner (Item 2A4) is used, steel studs cut in lengths 3/4 to 1-3/4 in. (19 to 44 mm) less than floor to ceiling height and secured
to slotted ceiling runner with No. 8 by 1/2 (13 mm) long wafer head steel screws at +/- 3/16 in. (5 mm) of the mid-height of slot on each side of
wall.
C. Gypsum Board* — 5/8 in. (16 mm) thick, 4 ft (1.22 m) wide with square or tapered edges. The gypsum board type, number of layers an sheet
orientation shall be as specified in the individual U400 or V400 Series Design in the Fire Resistance Directory, except that a max 1-1/2 in. (38
mm) gap shall be maintained between top edge of the gypsum board and the spray applied fire resistive material on the structural steel
support. The top row of screws shall be installed into the studs 1-1/2 in. (38 mm) below the bottom of the ceiling runner.
D. Steel Attachment Clips — (Optional - Not Shown) - As an alternate to steel fasteners, ceiling runner secured to steel beam with Z-shaped
clips formed from min 1 in. (25 mm) long strips of min 20 ga galv steel. Length of clips should not exceed the width (thickness) of the wall.
Clips to be sized to extend through the thickness of the spray-applied fire-resistive material on the bottom flange of the steel beam with 1-1/2
or 2 in. (38 or 51 mm) long upper and lower legs. Legs of clips fastened to bottom of beam (prior to application of spray-applied fire-resistive
materials) and top of ceiling runner with steel fasteners or welds. Clips spaced max 24in. (610 mm) OC.
The hourly ratings of the joint system are dependent on the hourly rating of the wall.
3. Joint System — Max separation between bottom of spray-applied fire resistive material on beam and top of gypsum board at time of installation is
1-1/2 in. (38 mm). The joint system is designed to accommodate a max 50 percent compression or extension from its installed width. The joint
system consists of a forming material and a fill material between the top of the gypsum board and the bottom of the spray-applied fire resistive
material on the beam, as follows:
A. Forming Material* — Nominal 4 pcf (64 kg/m3) mineral wool forming material cut into strips to fill the gap between top of the gypsum board
and bottom of beam. Width of the strips shall be equal to the total thickness of the gypsum board. The strips of mineral wool shall be
compressed 50 percent in thickness and firmly packed into the gap between the top of gypsum board and bottom of beam.
ROCK WOOL MANUFACTURING CO — Delta Board
ROCKWOOL — SAFE
THERMAFIBER INC — Type SAF
A1. Forming Material* - Strips — (Optional) - Nom 5/8 in. (16 mm) and 1-1/4 in. (32 mm) wide by 2 in. (51 mm) high precut mineral wool strips
for 1 and 2 hr rated assemblies respectively. The strips are compressed 50 percent and firmly packed, cut edge first, into the gap between the
top of the gypsum board and bottom of the steel floor units on both sides of the wall.
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP 767 Speed Strips
B. Fill, Void or Cavity Material* — Min 1/16 in. (1.6 mm) dry thickness (min 1/8 in. or 3.2 mm wet thickness) of fill material sprayed or troweled
on each side of wall to completely cover mineral wool forming material and to overlap 1/2 in. (13 mm) onto gypsum board and 2 in. (51 mm)
onto spray-applied fire resistive material on the structural steel support.
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP672 Firestop Spray or CFS-SP WB Firestop Joint Spray

* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada),
respectively.

Reproduced by HILTI, Inc. Courtesy of


Underwriters Laboratories, Inc.
September 26, 2019
Hilti Firestop Systems Page: 3 of 3
Product Information

Firestop Joint Spray


(CFS-SP WB)

Introduction
Product description
■■ A sprayable fire-rated mastic for construction joints where
maximum movement is required

Product features
■■ Sprayable or apply by brush
■■ Maximum flexibility, meets 500 cycle requirements (Class II and III
Approval) (ASTM E 1966 and UL 2079) )LUHVWRS

■■ Quick and easy installation with the Titan 600 or 1100 Sprayers
6\VWHP

Applications and Products


)LUHVWRS6\VWHP
can help save you time and money ,GHQWLILFDWLRQ/DEHO
■■ Contains no halogens, solvents or asbestos
■■ Water based formulation so spills and over-spray clean up quickly
and easily
■■ Paintable
Technical Data* CFS-SP WB
Density Approx. 10.8 lb/gal (1.3 g/cm3)
■■ Meets LEED™ requirements for indoor environmental quality credit
4.1 Low Emitting Materials, Sealants and Adhesives and 4.2 Paints Color Available in red, white and gray**
and Coatings Application temperature 39°F to 104°F (4°C to 40°C)
Temperature resistance -40°F to 176°F (-40°C to 80°C)
Areas of application
Consistency Sprayable liquid
■■ Top-of-wall joints
Chemical basis Acrylic-water-based-dispersion
■■ Curtain wall/edge of slab
Curing time Approx. 24 hours @ 73°F,
■■ Expansion joints
50% humidity for 1/8" depth

Selector Guide
For use with Average volume shrinkage 51.1%
■■ Concrete, masonry and gypsum wall assemblies (ASTM C1241)
■■ Wall and floor/wall assemblies rated up to 4 hours Ph-value Approx. 8-9
Movement capability Up to 50%
Examples Surface burning characteristics Flame spread: 15
■■ Where a gypsum wall assembly meets the underside of a metal or (CAN/ULC-S102) Smoke development: 10
concrete deck
Sound transmission classification 59
■■ Where a concrete floor assembly meets with non-rated exterior (ASTM E 90-99) (per tested construction type)
wall (concrete, glass, etc.) Tested in accordance with
■■ Where two concrete floor/wall assemblies meet • UL 2079 • ASTM E 1966 • ASTM E 84 • ASTM E 2837

Through-Penetration
• UL 1479 • ASTM E 814 • ASTM E 2307
*At 73°F (23°C) and 50% relative humidity
**Gray color requires six (6) weeks lead time

FILL, VOID OR CAVITY MATERIAL


FOR USE IN THROUGH-PENETRATION
FIRESTOP SYSTEMS, AND/OR JOINT FM
SYSTEMS, AND/OR PERIMETER
FIRE CONTAINMENT SYSTEMS $33529('
SEE UL FIRE RESISTANCE DIRECTORY )RU3HQHWUDWLRQ)LUH6WRSV
66Y7 &RQVXOWWKH)DFWRU\0XWXDO5HVHDUFK&RUSRUDWLRQ$SSURYDO*XLGH

Installation instructions for Firestop Joint Spray CFS-SP WB


Notice Application of Firestop Joint Spray Firestop Joint Spray may also be brushed on with a
• Before handling, read Material Safety Data Sheet and 2. Mineral wool packing: Install the prescribed back paint brush. Contact Hilti Technical Support for more
product label for safe usage and health information. filling material type and depth to obtain desired information.

Joint
• Instructions below are general guidelines — always rating. 4. Curing time: Allow approx. 24 hours for typical
refer to the applicable drawing in the UL Fire 3. Application of Firestop Joint Spray: Apply Firestop application thickness (@ 73°F / 23°C) 50% humidity
Resistance Directory or Hilti Firestop Systems Guide Joint Spray to the required depth in order to obtain for 1/8" depth for the Firestop Joint Spray to fully
for complete installation information the desired rating. Make sure Firestop Joint Spray cure.
contacts all surfaces and overlaps beyond all 5. Identification: For maintenance reasons all Firestop
Opening surrounding surfaces (Refer to UL System). Titan Joint Spray applications can be permanently marked
1. Clean the opening. Surfaces to which Firestop Joint Sprayers have been successful in applying Firestop with an identification plate and fastened in a visible
Spray will be applied should be cleaned of loose Joint Spray. Hilti recommends the use of the Titan position next to the seal.
debris, dirt, oil, wax and grease. The surface should 600 (for application temperatures above 50°F) or
be moisture and frost free. Not for use
Reference Data

• In areas immersed in water


FILL, VOID OR CAVITY MATERIALS
• On hot surfaces (above 176°F)
CLASSIFIED BY
UNDERWRITERS LABORATORIES, INC.
Storage FOR USE IN TROUGH-PENETRATION
FIRESTOP SYSTEMS
• Store only in the original packaging at temperatures
R

SEE UL FIRE RESISTANCE DIRECTORY


)LUHVWRS
39°F to 77°F (4°C to 25°C) 66Y7
6\VWHP
• Observe expiration date on package
1. Clean opening 2. Pack in mineral wool 3. Spray or brush on 4. Allow Firestop Spray 5. Fasten identification plate
compressed per UL Firestop Spray to cure (if required)
System

Hilti. Outperform. Outlast.


Hilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide
CERTIFICATE OF COMPLIANCE
Certificate Number 20170203 – R13240
Report Reference R13240 - 20100527
Issue Date 2017-FEBRUARY-03

Issued to: HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC


7250 Dallas Pky, Legacy Tower Suite 1000
Plano, TX 75024 USA

This is to certify that Fill, Void or Cavity Materials


representative samples of CFS-SP WB Firestop Joint Spray

Have been investigated by UL in accordance with the


Standard(s) indicated on this Certificate.

Standard(s) for Safety: ANSI/UL 1479, "Fire Tests of Penetration Firestops,"


ANSI/UL 2079, "Tests for Fire Resistance of Building Joint
Systems," ANSI/ASTM E2307, "Standard Test Method for
Determining Fire Resistance of Perimeter Fire Barriers
Using Intermediate-Scale, Multi-story Test Apparatus" and
CAN/ULC-S115, "Standard Method of Fire Tests of Firestop
Systems."
Additional Information: See the UL Online Certifications Directory at
www.ul.com/database for additional information

Only those products bearing the UL Certification Mark should be considered as being covered by UL's
Certification and Follow-Up Service.

Look for the UL Certification Mark on the product.

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 1 of 1
CFS-SP WB; CP 672
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
Date of issue: 11/07/2017 Revision date: 11/07/2017 Supersedes: 12/12/2016 Version: 4.3

SECTION 1: Identification
1.1. Identification
Product form Mixture
Trade name CFS-SP WB; CP 672
Product code BU Fire Protection
Chemical structure

1.2. Relevant identified uses of the substance or mixture and uses advised against
Use of the substance/mixture Flexible joint spray

1.3. Details of the supplier of the safety data sheet


Hilti, Inc.
Legacy Tower, Suite 1000
7250 Dallas Parkway
75024 Plano - USA
T +1 9724035800
1-800-879-8000 toll free - F +1 918 254 0522

Supplier Department issuing data specification sheet


Hilti, Inc. Hilti AG
Legacy Tower, Suite 1000 Feldkircherstraße 100
7250 Dallas Parkway 9494 Schaan - Liechtenstein
75024 Plano - USA T +423 234 2111
T +1 9724035800 chemicals.hse@hilti.com
1-800-879-8000 toll free - F +1 918 254 0522

1.4. Emergency telephone number

Emergency number Chem-Trec


Tel.: 1 800 424 9300 (USA, PR, Virgin Islands, Canada)
Tel.: 703 527 3887 (Other countries)
+1 918 8723000
1-800-879-8000 toll free

SECTION 2: Hazards identification

2.1. Classification of the substance or mixture


GHS-US classification
Repr. 2 H361 - Suspected of damaging fertility or the unborn child.
Full text of H statements : see section 16

07/11/2017 US-OSHA - en 1/8


CFS-SP WB; CP 672
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations

2.2. Label elements


GHS-US labelling
Hazard pictograms (GHS-US)

GHS08
Signal word (GHS-US) Warning
Hazard statements (GHS-US) H361 - Suspected of damaging fertility or the unborn child.
Precautionary statements (GHS-US) P280 - Wear protective gloves/protective clothing/eye protection/face protection.
P308+P313 - If exposed or concerned: Get medical advice/attention.

2.3. Other hazards


No additional information available

2.4. Unknown acute toxicity (GHS US)


Not applicable

SECTION 3: Composition/information on ingredients


3.1. Substances
Not applicable

3.2. Mixtures

Name Product identifier % GHS-US classification


hexaboron dizinc undecaoxide (CAS-No.) 12767-90-7 1 - 2.5 Repr. 2, H361
Aquatic Chronic 2, H411
Full text of H-statements: see section 16

SECTION 4: First aid measures


4.1. Description of first aid measures
First-aid measures after inhalation Get medical advice/attention if you feel unwell.
First-aid measures after skin contact Wash skin with plenty of water. If skin irritation occurs: Get medical advice/attention.
First-aid measures after eye contact Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to
do. Continue rinsing. If eye irritation persists: Get medical advice/attention.
First-aid measures after ingestion Get medical advice/attention if you feel unwell.

4.2. Most important symptoms and effects (acute and delayed)


No additional information available

4.3. Immediate medical attention and special treatment, if necessary

SECTION 5: Firefighting measures


5.1. Extinguishing media
Suitable extinguishing media Water spray. Dry powder. Foam. Carbon dioxide.

5.2. Special hazards arising from the substance or mixture


Reactivity The product is non-reactive under normal conditions of use, storage and transport.

07/11/2017 US-OSHA - en 2/8


CFS-SP WB; CP 672
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations

5.3. Advice for firefighters


Protection during firefighting Self-contained breathing apparatus. Complete protective clothing.

SECTION 6: Accidental release measures


6.1. Personal precautions, protective equipment and emergency procedures
6.1.1. For non-emergency personnel
No additional information available
6.1.2. For emergency responders
Protective equipment For further information refer to section 8: "Exposure controls/personal protection".

6.2. Environmental precautions


No additional information available

6.3. Methods and material for containment and cleaning up


Methods for cleaning up Mechanically recover the product.

6.4. Reference to other sections


For further information refer to section 13.

SECTION 7: Handling and storage


7.1. Precautions for safe handling
Precautions for safe handling Wear personal protective equipment.
Hygiene measures Wash contaminated clothing before reuse. Do not eat, drink or smoke when using this product.
Always wash hands after handling the product.

7.2. Conditions for safe storage, including any incompatibilities


Storage conditions Keep cool. Store in a dry place.
Storage temperature 41 - 77 °F

SECTION 8: Exposure controls/personal protection


8.1. Control parameters
hexaboron dizinc undecaoxide (12767-90-7)
ACGIH ACGIH TWA (mg/m³) 2 mg/m³ (Borate compounds, inorganic; USA; Time-
weighted average exposure limit 8 h; TLV - Adopted
Value; Inhalable fraction)
ACGIH ACGIH STEL (mg/m³) 6 mg/m³ (Borate compounds, inorganic; USA; Short
time value; TLV - Adopted Value; Inhalable fraction)

8.2. Exposure controls


Personal protective equipment Protective clothing. Safety glasses. Gloves.

Hand protection Protective gloves. EN 374.


Eye protection Safety glasses. EN 166. EN 170.

07/11/2017 US-OSHA - en 3/8


CFS-SP WB; CP 672
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations

Skin and body protection Wear suitable protective clothing.


Respiratory protection Not necessary with sufficient ventilation.
Environmental exposure controls Avoid release to the environment.
Other information Do not eat, drink or smoke during use.

SECTION 9: Physical and chemical properties


9.1. Information on basic physical and chemical properties
Physical state Liquid
Appearance Pasty.
Colour white red Grey
Odour characteristic
Odour threshold Not determined
pH ≈ 8.6
Melting point Not applicable
Freezing point No data available
Boiling point No data available
Flash point Not applicable
Relative evaporation rate (butylacetate=1) No data available
Flammability (solid, gas) No data available
Explosive limits No data available
Explosive properties No data available
Oxidising properties No data available
Vapour pressure No data available
Relative density No data available
Relative vapour density at 20 °C No data available
Density 1.28 kg/l
Molecular mass Not determined
Solubility No data available
Log Pow No data available
Auto-ignition temperature No data available
Decomposition temperature No data available
Viscosity No data available
Viscosity, kinematic No data available
Viscosity, dynamic No data available

9.2. Other information


VOC content 34 g/l EPA Method 24

SECTION 10: Stability and reactivity


10.1. Reactivity
The product is non-reactive under normal conditions of use, storage and transport.

10.2. Chemical stability


Stable under normal conditions.

10.3. Possibility of hazardous reactions


No dangerous reactions known under normal conditions of use.

07/11/2017 US-OSHA - en 4/8


CFS-SP WB; CP 672
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations

10.4. Conditions to avoid


None under recommended storage and handling conditions (see section 7).

10.5. Incompatible materials


No additional information available

10.6. Hazardous decomposition products


Under normal conditions of storage and use, hazardous decomposition products should not be produced.

SECTION 11: Toxicological information


11.1. Information on toxicological effects

Acute toxicity Not classified

Skin corrosion/irritation Not classified


pH: ≈ 8.6
Serious eye damage/irritation Not classified
pH: ≈ 8.6
Respiratory or skin sensitisation Not classified
Germ cell mutagenicity Not classified
Carcinogenicity Not classified

Reproductive toxicity Suspected of damaging fertility or the unborn child.


Specific target organ toxicity (single exposure) Not classified

Specific target organ toxicity (repeated Not classified


exposure)

Aspiration hazard Not classified

SECTION 12: Ecological information


12.1. Toxicity
Ecology - general The product is not considered harmful to aquatic organisms nor to cause long-term adverse
effects in the environment.

hexaboron dizinc undecaoxide (12767-90-7)


LC50 fish 1 2.4 mg/l (LC50; 96 h)
EC50 Daphnia 1 76 mg/l (LC50; 48 h)

12.2. Persistence and degradability


hexaboron dizinc undecaoxide (12767-90-7)
Persistence and degradability Biodegradability: not applicable. Adsorbs into the soil.
Biochemical oxygen demand (BOD) Not applicable

Chemical oxygen demand (COD) Not applicable

ThOD Not applicable

12.3. Bioaccumulative potential


No additional information available

07/11/2017 US-OSHA - en 5/8


CFS-SP WB; CP 672
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations

12.4. Mobility in soil


No additional information available

12.5. Other adverse effects


Effect on the global warming No known effects from this product.

SECTION 13: Disposal considerations


13.1. Waste treatment methods
Waste treatment methods Dispose of contents/container in accordance with licensed collector’s sorting instructions.
Product/Packaging disposal recommendations Dispose in a safe manner in accordance with local/national regulations.

SECTION 14: Transport information


In accordance with ADR / RID / IMDG / IATA / ADN

ADR IMDG IATA RID


14.1. UN number
Not regulated for transport

14.2. UN proper shipping name


Not applicable Not applicable Not applicable Not applicable

14.3. Transport hazard class(es)


Not applicable Not applicable Not applicable Not applicable
Not applicable Not applicable Not applicable Not applicable

14.4. Packing group


Not applicable Not applicable Not applicable Not applicable

14.5. Environmental hazards


Dangerous for the environment : Dangerous for the environment : Dangerous for the environment : Dangerous for the environment :
No No No No
Marine pollutant : No
No supplementary information available

14.6. Special precautions for user

- Overland transport

- Transport by sea
No data available

- Air transport
No data available

- Rail transport
Carriage prohibited (RID) No

14.7. Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code

07/11/2017 US-OSHA - en 6/8


CFS-SP WB; CP 672
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations

SECTION 15: Regulatory information


15.1. US Federal regulations
All components of this product are listed, or excluded from listing, on the United States Environmental Protection Agency Toxic Substances
Control Act (TSCA) inventory

15.2. International regulations


CANADA
CFS-SP WB; CP 672
WHMIS Classification Uncontrolled product according to WHMIS classification criteria

EU-Regulations
No additional information available

Classification according to Regulation (EC) No. 1272/2008 [CLP]


Not classified

National regulations
No additional information available

15.3. US State regulations

California Proposition 65 - This product contains, or may contain, trace quantities of a substance(s) known to the
state of California to cause cancer, developmental and/or reproductive harm

Ethylen glycole (107-21-1)


U.S. - California - U.S. - California - U.S. - California - U.S. - California - No significant risk
Proposition 65 - Proposition 65 - Proposition 65 - Proposition 65 - level (NSRL)
Carcinogens List Developmental Toxicity Reproductive Toxicity - Reproductive Toxicity -
Female Male
No Yes No No 8400µg
Diisononyl phthalate (DINP)
U.S. - California - U.S. - California - U.S. - California - U.S. - California - No significant risk
Proposition 65 - Proposition 65 - Proposition 65 - Proposition 65 - level (NSRL)
Carcinogens List Developmental Toxicity Reproductive Toxicity - Reproductive Toxicity -
Female Male
Yes No No No 147µg

SECTION 16: Other information


Revision date 11/07/2017

Full text of H-statements:


------ H361 Suspected of damaging fertility or the unborn child.
------ H411 Toxic to aquatic life with long lasting effects.

NFPA health hazard 0 - Materials that, under emergency conditions, would offer
no hazard beyond that of ordinary combustible materials.
NFPA fire hazard 0 - Materials that will not burn under typical dire conditions,
including intrinsically noncombustible materials such as
concrete, stone, and sand.
NFPA reactivity 0 - Material that in themselves are normally stable, even
under fire conditions.

07/11/2017 US-OSHA - en 7/8


CFS-SP WB; CP 672
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations

Hazard Rating
Health 0 Minimal Hazard - No significant risk to health
Flammability 0 Minimal Hazard - Materials that will not burn
Physical 0 Minimal Hazard - Materials that are normally stable, even under fire conditions, and will NOT
react with water, polymerize, decompose, condense, or self-react. Non-Explosives.
Personal protection B
B - Safety glasses, Gloves

Indication of changes:
Section Changed item Change Comments
U.S. - California - Proposition Added
65 - Developmental Toxicity
U.S. - California - Proposition Added
65 - Carcinogens List
Display TSCA summary in 15.1 Added
S_US_Hilti

This information is based on our current knowledge and is intended to describe the product for the purposes of health, safety and
environmental requirements only. It should not therefore be construed as guaranteeing any specific property of the product

07/11/2017 US-OSHA - en 8/8


September 12, 2016

To Whom It May Concern:

Re: Hilti CFS-SP WB Firestop Joint Spray – LEED Information

Item Numbers:

430792
430793
430802

The Hilti CFS-SP WB Firestop Joint Spray is manufactured in Florida.

The CFS-SP WB pail is made of polyethylene and can be completely recycled.

There is no post-consumer or post-industrial content in CFS-SP WB Firestop Joint Spray and it cannot be recycled. The CFS-SP
WB does not contain any Rapidly Renewable Materials.

The VOC content for CFS-SP WB Firestop Joint Spray is 34 g/l.

CFS-SP WB Firestop Joint Spray is not regulated as hazardous waste by the Federal EPA Standards. The regulations for the
disposal of non-regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult
your local and state regulatory agencies for direction on disposal.

Please feel free to contact me at (918) 872-3704 if you have questions.

Sincerely,

Jerry Metcalf MPH, CHMM


Sr. Manager, Safety/Environmental
Hilti Inc.
918 872 3704
jerry.metcalf@hilti.com

Rev. Date: 8/14/15

The manufacturing plant location on this certificate has been provided for LEEDS reporting purposes only. It should never be used
for Country of Origin certification or a representation of compliance/non-compliance with Buy American or Buy America
requirements, as those requirements differ.

The manufacturing plant location(s) identified on the certificate represent standard Hilti catalog products only. “Specially” produced
non-catalog Hilti products may have differing manufacturing plant locations.

Contact your Hilti representative in cases of “specially” produced products for a custom LEEDS certificates.

Hilti, Inc.
5400 South 122 n d East Avenue
Tulsa, OK 74146

1-800-879-8000
www.hilti.com
Product Information

Flexible Firestop Sealant


(CP 606)

Introduction
Product description
■■ An acrylic based firestop sealant that provides movement
capability in fire rated joints and seals through-penetrations
applications

Product features
■■ Silicone free
■■ Halogen, asbestos and solvent free
■■ Paintable

Applications and Products


■■ Tested up to 33% movement with 500 cycles in accordance to UL
2079 and ASTM 1966
■■ Smoke and fume resistant
■■ Easy clean up with water Technical Data* CP 606
■■ Single component systems available Chemical basis Acrylic based firestop sealant
■■ Meets LEED™ requirements for indoor environmental quality credit Color Available in red, white and gray
4.1 Low Emitting Materials, Sealants and Adhesives and 4.2 Paints Application temperature 40°F to 104°F (5°C to 40°C)
and Coatings
Skin-forming time Approx. 15 min
Areas of application Curing time Approx. 3 mm / 3 days
■■ Sealing construction/expansion joints Average volume shrinkage 22.2%
■■ Top-of-wall joints (ASTM C1241)
■■ Metal pipes Movement capability Approx. 10%

Selector Guide
■■ Cable bundles Temperature resistance –22°F to 176°F (–30°C to 80°C)
■■ HVAC penetrations Surface burning characteristics Flame Spread: 10
(ASTM E 84-96) Smoke Development: 0
For use with Sound transmission classification 56
■■ Various base materials such as masonry, concrete, gypsum, etc. (ASTM E 90-99) (Relates to specific construction)
■■ Wall and floor assemblies rated up to 3 hours Tested in accordance with
• UL 2079 • ASTM E 814 • ASTM E 1966
Examples • ASTM E 84 • UL 1479 • ASTM G21
■■ Where a gypsum wall assembly meets the underside of a metal or
*At 73°F (23°C) and 50% relative humidity
concrete deck

Through-Penetration
■■ Sealing expansion joints to impede the passage of fire, smoke and
FILL, VOID OR CAVITY MATERIAL
toxic fumes FOR USE IN THROUGH-PENETRATION
FM
■■ Sealing around HVAC penetrations through fire-rated assemblies FIRESTOP SYSTEMS AND
JOINT SYSTEMS
SEE UL FIRE RESISTANCE DIRECTORY $33529('
66Y7 )RU3HQHWUDWLRQ)LUH6WRSV
&RQVXOWWKH)DFWRU\0XWXDO5HVHDUFK&RUSRUDWLRQ$SSURYDO*XLGH

Installation instructions for CP 606


Notice permanently marked with an identification plate and Storage
• Before handling, read Material Safety Data Sheet and fastened in a visible position next to the seal. • Store only in the original packaging in a location
product label for safe usage and health information. protected from moisture at a temperature of 40°F to
Not for use 77°F (5°C to 25°C)
• Instructions below are general guidelines — always • On areas immersed in water
refer to the applicable drawing in the UL Fire • Observe expiration date on package
Resistance Directory or Hilti Firestop Systems Guide
for complete installation information
• The use of backing material is recommended to

Joint
JOINT

control the sealant depth and help ensure assembly


seal is complete
Firestop
System

Opening
1. Clean the opening. Surfaces to which CP 606 will
be applied should be cleaned of loose debris, dirt, 1. Clean opening 2. Insert backing 3. Apply CP 606 4. Smooth CP 606 5. Fasten identification
oil, wax and grease. The surface should be moisture material compressed plate (if required)
per UL System FILL, VOID OR CAVITY MATERIALS
and frost free.
CLASSIFIED BY
UNDERWRITERS LABORATORIES, INC.
Application of firestop FOR USE IN TROUGH-PENETRATION
2. Insert fill of mineral wool or backer (as required). R FIRESTOP SYSTEMS
DUCT

SEE UL FIRE RESISTANCE DIRECTORY


3. Apply firestop over backer.
Reference Data

66Y7
4. Smooth firestop sealant with a trowel before the skin
forms. Once cured, CP 606 can only be removed Firestop

mechanically.
System

5. For maintenance reasons, a penetration seal can be 1. Clean opening 2. Insert backing 3. Apply CP 606 4. Smooth CP 606 5. Fasten identification
material plate (if required)

Hilti. Outperform. Outlast.


Hilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide
CERTIFICATE OF COMPLIANCE
Certificate Number 20160930-R13240
Report Reference R13240
Issue Date 2016-September-30

Issued to: Hilti Construction Chemicals, Div of Hilti Inc.


5400 S 122nd East Ave
Tulsa, OK 74146

This is to certify that Fill, Void or Cavity Materials


representative samples of Fill, Void or Cavity Materials Certified for Canada

CP 606 Sealant for use in Through-Penetration Firestop,


Joint in wall and partition Systems as currently decribed in
the UL Fire Resistance Directory and in the Products
Certified for Canada Directory.

Have been investigated by UL in accordance with the


Standard(s) indicated on this Certificate.

Standard(s) for Safety: ANSI/UL 1479, "Fire Tests of Through-Penetration


Firestops,"
ANSI/UL 2079, "Tests for Fire Resistance of Building Joint
Systems,"
CAN/ULC-S115, "Standard Method of Fire Tests of Firestop
Systems."
Additional Information: See the UL Online Certifications Directory at
www.ul.com/database for additional information

Only those products bearing the UL Certification Mark should be considered as being covered by UL's
Certification and Follow-Up Service.

Look for the UL Certification Mark on the product.

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 1 of 1
Hilti Firestop Acrylic Sealant CFS-S ACR; CP 606
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
Date of issue: 01/07/2016 Revision date: 01/07/2016 Supersedes: 01/07/2016 Version: 4.2

SECTION 1: Identification
1.1. Identification
Product form Mixture
Name Hilti Firestop Acrylic Sealant CFS-S ACR; CP 606
Product code BU Chemicals
Chemical structure

1.2. Relevant identified uses of the substance or mixture and uses advised against
No additional information available

1.3. Details of the supplier of the safety data sheet


Hilti, Inc.
Legacy Tower, Suite 1000
75024 Plano - USA
T +1 9724035800
1-800-879-8000 toll free - F +1 918 254 0522

Supplier Department issuing data specification sheet


Hilti, Inc. Hilti AG
Legacy Tower, Suite 1000 Feldkircherstraße 100
75024 Plano - USA 9494 Schaan - Liechtenstein
T +1 9724035800 T +423 234 2111
1-800-879-8000 toll free - F +1 918 254 0522 chemicals.hse@hilti.com

1.4. Emergency telephone number

Emergency number Chem-Trec


Tel.: 1 800 424 9300 (USA, PR, Virgin Islands, Canada)
Tel.: 703 527 3887 (Other countries)
+1 918 8723000
1-800-879-8000 toll free

SECTION 2: Hazards identification


2.1. Classification of the substance or mixture
GHS-US classification
Not classified

2.2. Label elements


GHS-US labelling
No labelling applicable

2.3. Other hazards


No additional information available

2.4. Unknown acute toxicity (GHS US)


Not applicable

07/01/2016 EN (English) 1/7


Hilti Firestop Acrylic Sealant CFS-S ACR; CP 606
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations

SECTION 3: Composition/information on ingredients


3.1. Substance
Not applicable

3.2. Mixture
Full text of H-statements: see section 16

SECTION 4: First aid measures


4.1. Description of first aid measures
First-aid measures after inhalation Get medical advice/attention if you feel unwell.
First-aid measures after skin contact Wash skin with plenty of water. If skin irritation occurs: Get medical advice/attention.
First-aid measures after eye contact Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to
do. Continue rinsing. If eye irritation persists: Get medical advice/attention.
First-aid measures after ingestion Get medical advice/attention if you feel unwell.

4.2. Most important symptoms and effects, both acute and delayed
No additional information available

4.3. Indication of any immediate medical attention and special treatment needed
No additional information available

SECTION 5: Firefighting measures


5.1. Extinguishing media
Suitable extinguishing media Water spray. Dry powder. Foam. Carbon dioxide.

5.2. Special hazards arising from the substance or mixture


Reactivity The product is non-reactive under normal conditions of use, storage and transport.

5.3. Advice for firefighters


Protection during firefighting Self-contained breathing apparatus. Complete protective clothing.

SECTION 6: Accidental release measures


6.1. Personal precautions, protective equipment and emergency procedures
6.1.1. For non-emergency personnel
No additional information available
6.1.2. For emergency responders
Protective equipment For further information refer to section 8: "Exposure controls/personal protection".

6.2. Environmental precautions


No additional information available

6.3. Methods and material for containment and cleaning up


Methods for cleaning up Recover mechanically the product.

6.4. Reference to other sections


For further information refer to section 13.

07/01/2016 EN (English) 2/7


Hilti Firestop Acrylic Sealant CFS-S ACR; CP 606
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations

SECTION 7: Handling and storage


7.1. Precautions for safe handling
Precautions for safe handling Wear personal protective equipment.
Hygiene measures Wash contaminated clothing before reuse. Do not eat, drink or smoke when using this product.
Always wash hands after handling the product.

7.2. Conditions for safe storage, including any incompatibilities


Storage conditions Keep cool. Store in a dry place.
Storage temperature 41 - 77 °F

SECTION 8: Exposure controls/personal protection


8.1. Control parameters
No additional information available

8.2. Exposure controls


Personal protective equipment Protective clothing. Safety glasses. Gloves.

Hand protection Protective gloves. EN 374.


Eye protection Safety glasses. EN 166. EN 170.
Skin and body protection Wear suitable protective clothing.

SECTION 9: Physical and chemical properties


9.1. Information on basic physical and chemical properties
Physical state Liquid
Appearance Pasty.
Colour red white Grey
Odour characteristic
Odour threshold Not determined
pH ≈ 9 Not applicable
Melting point Not applicable
Freezing point No data available
Boiling point No data available
Flash point Not applicable
Relative evaporation rate (butylacetate=1) No data available
Flammability (solid, gas) No data available
Explosive limits No data available
Explosive properties No data available
Oxidising properties No data available
Vapour pressure No data available
Relative density No data available
Relative vapour density at 20 °C No data available
Density 1.6 g/cm³
Molecular mass Not determined
Solubility No data available

07/01/2016 EN (English) 3/7


Hilti Firestop Acrylic Sealant CFS-S ACR; CP 606
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations

Log Pow No data available


Auto-ignition temperature No data available
Decomposition temperature No data available
Viscosity No data available
Viscosity, kinematic No data available
Viscosity, dynamic No data available

9.2. Other information


No additional information available

SECTION 10: Stability and reactivity


10.1. Reactivity
The product is non-reactive under normal conditions of use, storage and transport.

10.2. Chemical stability


Stable under normal conditions.

10.3. Possibility of hazardous reactions


No dangerous reactions known under normal conditions of use.

10.4. Conditions to avoid


None under recommended storage and handling conditions (see section 7).

10.5. Incompatible materials


No additional information available

10.6. Hazardous decomposition products


Under normal conditions of storage and use, hazardous decomposition products should not be produced.

SECTION 11: Toxicological information


11.1. Information on toxicological effects

Acute toxicity Not classified

Skin corrosion/irritation Not classified


pH: ≈ 9 Not applicable
Serious eye damage/irritation Not classified
pH: ≈ 9 Not applicable
Respiratory or skin sensitisation Not classified
Germ cell mutagenicity Not classified
Carcinogenicity Not classified
Reproductive toxicity Not classified
Specific target organ toxicity (single exposure) Not classified

Specific target organ toxicity (repeated Not classified


exposure)
Aspiration hazard Not classified

07/01/2016 EN (English) 4/7


Hilti Firestop Acrylic Sealant CFS-S ACR; CP 606
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations

SECTION 12: Ecological information


12.1. Toxicity
Ecology - general The product is not considered harmful to aquatic organisms or to cause long-term adverse
effects in the environment.

12.2. Persistence and degradability


No additional information available

12.3. Bioaccumulative potential


No additional information available

12.4. Mobility in soil


No additional information available

12.5. Other adverse effects


Effect on the global warming No known ecological damage caused by this product.

SECTION 13: Disposal considerations


13.1. Waste treatment methods
Waste treatment methods Dispose of contents/container in accordance with licensed collector’s sorting instructions.
Waste disposal recommendations Dispose in a safe manner in accordance with local/national regulations.

SECTION 14: Transport information


In accordance with ADR / RID / IMDG / IATA / ADN

14.1. UN number
Not regulated for transport

14.2. UN proper shipping name


Proper Shipping Name (ADR) Not applicable
Proper Shipping Name (IMDG) Not applicable
Proper Shipping Name (IATA) Not applicable
Proper Shipping Name (ADN) Not applicable
Proper Shipping Name (RID) Not applicable

14.3. Transport hazard class(es)


ADR
Transport hazard class(es) (ADR) Not applicable

IMDG
Transport hazard class(es) (IMDG) Not applicable

IATA
Transport hazard class(es) (IATA) Not applicable

ADN
Transport hazard class(es) (ADN) Not applicable

RID

07/01/2016 EN (English) 5/7


Hilti Firestop Acrylic Sealant CFS-S ACR; CP 606
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations

Transport hazard class(es) (RID) Not applicable

14.4. Packing group


Packing group (ADR) Not applicable
Packing group (IMDG) Not applicable
Packing group (IATA) Not applicable
Packing group (ADN) Not applicable
Packing group (RID) Not applicable

14.5. Environmental hazards


Dangerous for the environment No
Marine pollutant No
Other information No supplementary information available

14.6. Special precautions for user

- Overland transport

- Transport by sea
No data available

- Air transport
No data available

- Inland waterway transport


Carriage prohibited (ADN) No
Not subject to ADN No

- Rail transport
Carriage prohibited (RID) No

14.7. Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code

SECTION 15: Regulatory information


15.1. US Federal regulations
This product or mixture does not contain a toxic chemical or chemicals in excess of the applicable de minimis concentration as specified in 40 CFR
§372.38(a) subject to the reporting requirements of section 313 of Title III of the Superfund Amendments and Reauthorization Act of 1986 and 40
CFR Part 372.

15.2. International regulations


CANADA
Hilti Firestop Acrylic Sealant CFS-S ACR; CP 606
WHMIS Classification Uncontrolled product according to WHMIS classification criteria

EU-Regulations
No additional information available

Classification according to Regulation (EC) No. 1272/2008 [CLP]


Not classified

National regulations
No additional information available

07/01/2016 EN (English) 6/7


Hilti Firestop Acrylic Sealant CFS-S ACR; CP 606
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations

15.3. US State regulations


California Proposition 65 - This product does not contain any substances known to the state of California to cause
cancer, developmental and/or reproductive harm

SECTION 16: Other information


Revision date 01/07/2016

HMIS III Rating


Health 0 Minimal Hazard - No significant risk to health
Flammability 0 Minimal Hazard - Materials that will not burn
Physical 0 Minimal Hazard - Materials that are normally stable, even under fire conditions, and will NOT
react with water, polymerize, decompose, condense, or self-react. Non-Explosives.
Personal Protection B
B - Safety glasses, Gloves

SDS_US_Hilti

This information is based on our current knowledge and is intended to describe the product for the purposes of health, safety and
environmental requirements only. It should not therefore be construed as guaranteeing any specific property of the product

07/01/2016 EN (English) 7/7


February 26, 2010

To Whom It May Concern:

Re: Hilti CP 606 Flexible Firestop – LEEDs Info.

The Hilti CP 606 Flexible Firestop Sealant is manufactured in Germany.

The CP 606 pail is made of polyethylene and can be completely recycled. There is no post-
consumer or post-industrial content in CP 606 and it cannot be recycled. The CP 606 does not
contain any Rapidly Renewable Materials. The VOC content for CP 606 is 71.0 grams/liter.

CP 606 is not regulated as a hazardous waste by the Federal EPA Standards. The regulations for
the disposal of non-regulated industrial waste can vary from state to state and even city to city.
For this reason, you should consult your local and state regulatory agencies for direction on
disposal.

Please feel free to contact me at (918) 872-3704 if you have questions.

Sincerely,

Jerry Metcalf MPH, CHMM


Safety/Environmental Manager
Hilti Inc.
918 872 3704
jerry.metcalf@hilti.com

Rev. Date: 2/26/10

Hilti, Inc.
5400 South 122 n d East Avenue
Tulsa, OK 74146

1-800-879-8000
www.hilti.com
Product Information

SPEED STRIPS SPEED PLUGS


CP 767 CP 777
Product description
• CP 777: Pre-formed mineral wool plugs for 1.5”, 2” and 3” decks
• CP 767: Pre-formed mineral wool strips suitable for joint applications

Product features
• Pre-cut to industry standard size decking flutes
• Reduces material waste
• 3 sizes available
• Pre-cut — leaves no gaps or voids
• Smooth surface provides cost effective spray coverage
• Safer to use — no asbestos
• Up to 60% faster than castle cutting!
• CP 767: 4 PCF Density
• CP 777: 6 PCF Density

Areas of application
• Top-of-wall

Tested and approved


• UL Classified when used in conjunction with CP 606 Flexible Firestop Sealant,
CFS-S SIL GG Gun Grade Silicone Sealant, or CFS-SP WB Firestop Joint Spray

Installation instructions
• See Hilti literature or third-party listings for complete application and installation
details

Saves time and money! FORMING MATERIAL


FOR USE IN JOINT SYSTEMS
SEE UL FIRE RESISTANCE DIRECTORY
Castle cutting 50 MINUTES 17RL

Conventional mineral wool 35 MINUTES

Hilti speed plugs 20 MINUTES

60% Faster than castle cutting


43% Faster than conventional mineral wool
*Based upon 40 linear feet of installation. Actual results may vary.

Flute Dimensions
Description Qty Item No.
(L x (Flute) x H)

CP 777 1.5” Speed Plug 36” x (3.5” x 4.5”) x 1.5” 18 371925

CP 777 2” Speed Plug 36” x (4.5” x 5.5”) x 2” 18 340996

CP 777 3” Speed Plug 36” x (5” x 7”) x 3” 18 340999

CP 767 2” Speed Strips (1 hour) 36” x 0.625” x 2” 84 374507

CP 767 2” Speed Strips (2 hour) 36” x 1.25” x 2” 42 374508

CP 767 4” Speed Strips (1 hour) 36” x 0.625” x 4” 42 374505

CP 767 4” Speed Strips (2 hour) 36” x 1.25” x 4” 21 374506


DBS • 08/19

Hilti Firestop
Saving lives
through innovation
and education
CERTIFICATE OF COMPLIANCE
Certificate Number 20160829-R13081
Report Reference R13081
Issue Date 2016-August-29

Issued to: Hilti Construction Chemicals, Div of Hilti Inc.


7250 Dallas Pky, Legacy Tower Ste 1000
Plano, TX 75024 USA

This is to certify that Forming Materials


representative samples of Forming Materials Certified for Canada

CP767 Speed Strips and CP777 Speed Plugs Speed Strips


for use in Joint Systems as currently decribed in the UL Fire
Resistance Directory and in the Products Certified for
Canada Directory.

Have been investigated by UL in accordance with the


Standard(s) indicated on this Certificate.

Standard(s) for Safety: ANSI/UL 2079, "Tests for Fire Resistance of Building Joint
Systems."
CAN/ULC-S115, "Standard Method of Fire Tests of Firestop
Systems."
Additional Information: See the UL Online Certifications Directory at
www.ul.com/database for additional information

Only those products bearing the UL Certification Mark should be considered as being covered by UL's
Certification and Follow-Up Service.

Look for the UL Certification Mark on the product.

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 1 of 1
Material Information Statement
Manufactured Articles
According to 1907/2006/EC, Article 32
Revision: 23.04.2019 Version: 14

1 Identification of the manufactured articles and of the company undertaking


1.1 Product identifier

Trade name:

 Firestop Bandage CFS-B / CP 646  Firestop Module Box CFS-MB / CP 657


 Firestop Back Pan Strip CFS-BPS  Firestop Plug CFS-PL / CP 658
 Firestop Block CFS-BL / CFS-BL P  Firestop Plug Seal CFS-T RR / CFS-T RRS
 Firestop Board CP 675  Firestop Retrofit Sleeve CFS-SL RK
 Firestop Boot CFS-BO  Firestop Sleeve CP 645
 Firestop Box Insert  Firestop Sleeve Kit CFS-SL SK
 Firestop Cable Collar CFS-CC / CFS-RCC / CFS-RCC EXT  Firestop Speed Sleeve CFS-SL / CFS-SL GA / CP 653
 Firestop Cable Module CFS-T  Firestop Top Track Seal CFS-TTS
 Firestop Cast-in device CP 680 / CP 681 / CFS-CID /  Firestop Wedge Seal CFS-T WD120
 CFS-CID MD P/M  Firestop Wrap Strip CFS-W EL / SG / P / CP 648
 Firestop Coated Board CFS-CT B / CP670 / CP673 / CP676  Foil Tapes CS-FT
 Firestop Collar CFS-C / CFS-C P  Joint Sealing Tapes CS-JST
 Firestop Collar CP 643 / CP 644  Mineral Wool
 Firestop Composite Sheet CFS-COS  Mineral Wool Boards
 Firestop Cord CFS-CO  Multifunctional Tapes CS-MFT
 Firestop Cushion CP 651N  Pre-coated Mineral Wool Boards
 Firestop Drop-In Device CFS-DID  Smoke & Acoustic Track Seal CS-TTS SA
 Firestop Edge of Slab QuickSeal CFS-EOS QS  Speed Plug CP 777
 Firestop Endless Collar CFS-C EL  Speed Strip CP 767
 Firestop Filler Module CFS-T FB
 Firestop Gangplate CFS-SL GP

1.2 Application of the manufactured articles

Construction industry.
Refer to Hilti product literature, technical data sheets, 3rd party published listings and national approvals for specific application information. For
more details, please contact your local Hilti organization through http://www.hilti.group

1.3 Manufacturer / Supplier

Hilti AG
Feldkircherstr. 100
FL-9494 Schaan
Liechtenstein

Customer Service
Phone +423 (0)844 84 84 85
Fax +423 (0)844 84 84 86

2 Other information
A Safety Data Sheet is not required due to the classification of these products as “manufactured articles” according to Regulation (EC) No.
1907/2006 of 18 December 2006 (EU) / 29CFR 1910.1200 (U.S.A.). Consequently, these products are exempted from CLP / OSHA Labeling and
SDS requirements.

These data are based on our present knowledge. However, they shall not constitute a guarantee for any specific product features and shall not
establish a legally valid contractual relationship.

Informing department:
chemicals.hse@hilti.com
January 27, 2016

To Whom It May Concern:

Re: Hilti CP767 Speed Strips and CP777 Speed Plugs – LEED Information

Item Numbers:

CP 767 CP 777
374505 340998
374506 340999
374507 371925
374508

The Hilti CP767 Speed Strips and CP777 Speed Plugs are manufactured in North Carolina.

Post-consumer recycled content of Hilti CP767 Speed Strips and CP777 Speed Plugs is 0%. Pre-consumer recycled content of
Hilti CP767 Speed Strips and CP777 Speed Plugs is 0%. There is no detectable VOC content either product.

Hilti CP767 Speed Strips and CP777 Speed Plugs are not regulated as a hazardous waste by the Federal EPA Standards. The
regulations for the disposal of non-regulated industrial waste can vary from state to state and even city to city. For this reason, you
should consult your local and state regulatory agencies for direction on disposal.

Please feel free to contact me at (918) 872-3704 if you have questions.

Sincerely,

Jerry Metcalf MPH, CHMM


Sr. Manager, Safety/Environmental
Hilti Inc.
918 872 3704
jerry.metcalf@hilti.com

Rev. Date: 1/27/16

The manufacturing plant location on this certificate has been provided for LEEDS reporting purposes only. It should never be used
for Country of Origin certification or a representation of compliance/non-compliance with Buy American or Buy America
requirements, as those requirements differ.

The manufacturing plant location(s) identified on the certificate represent standard Hilti catalog products only. “Specially” produced
non-catalog Hilti products may have differing manufacturing plant locations.

Contact your Hilti representative in cases of “specially” produced products for a custom LEEDS certificates.

Hilti, Inc.
5400 South 122 n d East Avenue
Tulsa, OK 74146

1-800-879-8000
www.hilti.com
Product Information

SPEED STRIPS SPEED PLUGS


CP 767 CP 777
Product description
• CP 777: Pre-formed mineral wool plugs for 1.5”, 2” and 3” decks
• CP 767: Pre-formed mineral wool strips suitable for joint applications

Product features
• Pre-cut to industry standard size decking flutes
• Reduces material waste
• 3 sizes available
• Pre-cut — leaves no gaps or voids
• Smooth surface provides cost effective spray coverage
• Safer to use — no asbestos
• Up to 60% faster than castle cutting!
• CP 767: 4 PCF Density
• CP 777: 6 PCF Density

Areas of application
• Top-of-wall

Tested and approved


• UL Classified when used in conjunction with CP 606 Flexible Firestop Sealant,
CFS-S SIL GG Gun Grade Silicone Sealant, or CFS-SP WB Firestop Joint Spray

Installation instructions
• See Hilti literature or third-party listings for complete application and installation
details

Saves time and money! FORMING MATERIAL


FOR USE IN JOINT SYSTEMS
SEE UL FIRE RESISTANCE DIRECTORY
Castle cutting 50 MINUTES 17RL

Conventional mineral wool 35 MINUTES

Hilti speed plugs 20 MINUTES

60% Faster than castle cutting


43% Faster than conventional mineral wool
*Based upon 40 linear feet of installation. Actual results may vary.

Flute Dimensions
Description Qty Item No.
(L x (Flute) x H)

CP 777 1.5” Speed Plug 36” x (3.5” x 4.5”) x 1.5” 18 371925

CP 777 2” Speed Plug 36” x (4.5” x 5.5”) x 2” 18 340996

CP 777 3” Speed Plug 36” x (5” x 7”) x 3” 18 340999

CP 767 2” Speed Strips (1 hour) 36” x 0.625” x 2” 84 374507

CP 767 2” Speed Strips (2 hour) 36” x 1.25” x 2” 42 374508

CP 767 4” Speed Strips (1 hour) 36” x 0.625” x 4” 42 374505

CP 767 4” Speed Strips (2 hour) 36” x 1.25” x 4” 21 374506


DBS • 08/19

Hilti Firestop
Saving lives
through innovation
and education
CERTIFICATE OF COMPLIANCE
Certificate Number 20160829-R13081
Report Reference R13081
Issue Date 2016-August-29

Issued to: Hilti Construction Chemicals, Div of Hilti Inc.


7250 Dallas Pky, Legacy Tower Ste 1000
Plano, TX 75024 USA

This is to certify that Forming Materials


representative samples of Forming Materials Certified for Canada

CP767 Speed Strips and CP777 Speed Plugs Speed Strips


for use in Joint Systems as currently decribed in the UL Fire
Resistance Directory and in the Products Certified for
Canada Directory.

Have been investigated by UL in accordance with the


Standard(s) indicated on this Certificate.

Standard(s) for Safety: ANSI/UL 2079, "Tests for Fire Resistance of Building Joint
Systems."
CAN/ULC-S115, "Standard Method of Fire Tests of Firestop
Systems."
Additional Information: See the UL Online Certifications Directory at
www.ul.com/database for additional information

Only those products bearing the UL Certification Mark should be considered as being covered by UL's
Certification and Follow-Up Service.

Look for the UL Certification Mark on the product.

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 1 of 1
Material Information Statement
Manufactured Articles
According to 1907/2006/EC, Article 32
Revision: 23.04.2019 Version: 14

1 Identification of the manufactured articles and of the company undertaking


1.1 Product identifier

Trade name:

 Firestop Bandage CFS-B / CP 646  Firestop Module Box CFS-MB / CP 657


 Firestop Back Pan Strip CFS-BPS  Firestop Plug CFS-PL / CP 658
 Firestop Block CFS-BL / CFS-BL P  Firestop Plug Seal CFS-T RR / CFS-T RRS
 Firestop Board CP 675  Firestop Retrofit Sleeve CFS-SL RK
 Firestop Boot CFS-BO  Firestop Sleeve CP 645
 Firestop Box Insert  Firestop Sleeve Kit CFS-SL SK
 Firestop Cable Collar CFS-CC / CFS-RCC / CFS-RCC EXT  Firestop Speed Sleeve CFS-SL / CFS-SL GA / CP 653
 Firestop Cable Module CFS-T  Firestop Top Track Seal CFS-TTS
 Firestop Cast-in device CP 680 / CP 681 / CFS-CID /  Firestop Wedge Seal CFS-T WD120
 CFS-CID MD P/M  Firestop Wrap Strip CFS-W EL / SG / P / CP 648
 Firestop Coated Board CFS-CT B / CP670 / CP673 / CP676  Foil Tapes CS-FT
 Firestop Collar CFS-C / CFS-C P  Joint Sealing Tapes CS-JST
 Firestop Collar CP 643 / CP 644  Mineral Wool
 Firestop Composite Sheet CFS-COS  Mineral Wool Boards
 Firestop Cord CFS-CO  Multifunctional Tapes CS-MFT
 Firestop Cushion CP 651N  Pre-coated Mineral Wool Boards
 Firestop Drop-In Device CFS-DID  Smoke & Acoustic Track Seal CS-TTS SA
 Firestop Edge of Slab QuickSeal CFS-EOS QS  Speed Plug CP 777
 Firestop Endless Collar CFS-C EL  Speed Strip CP 767
 Firestop Filler Module CFS-T FB
 Firestop Gangplate CFS-SL GP

1.2 Application of the manufactured articles

Construction industry.
Refer to Hilti product literature, technical data sheets, 3rd party published listings and national approvals for specific application information. For
more details, please contact your local Hilti organization through http://www.hilti.group

1.3 Manufacturer / Supplier

Hilti AG
Feldkircherstr. 100
FL-9494 Schaan
Liechtenstein

Customer Service
Phone +423 (0)844 84 84 85
Fax +423 (0)844 84 84 86

2 Other information
A Safety Data Sheet is not required due to the classification of these products as “manufactured articles” according to Regulation (EC) No.
1907/2006 of 18 December 2006 (EU) / 29CFR 1910.1200 (U.S.A.). Consequently, these products are exempted from CLP / OSHA Labeling and
SDS requirements.

These data are based on our present knowledge. However, they shall not constitute a guarantee for any specific product features and shall not
establish a legally valid contractual relationship.

Informing department:
chemicals.hse@hilti.com
January 27, 2016

To Whom It May Concern:

Re: Hilti CP767 Speed Strips and CP777 Speed Plugs – LEED Information

Item Numbers:

CP 767 CP 777
374505 340998
374506 340999
374507 371925
374508

The Hilti CP767 Speed Strips and CP777 Speed Plugs are manufactured in North Carolina.

Post-consumer recycled content of Hilti CP767 Speed Strips and CP777 Speed Plugs is 0%. Pre-consumer recycled content of
Hilti CP767 Speed Strips and CP777 Speed Plugs is 0%. There is no detectable VOC content either product.

Hilti CP767 Speed Strips and CP777 Speed Plugs are not regulated as a hazardous waste by the Federal EPA Standards. The
regulations for the disposal of non-regulated industrial waste can vary from state to state and even city to city. For this reason, you
should consult your local and state regulatory agencies for direction on disposal.

Please feel free to contact me at (918) 872-3704 if you have questions.

Sincerely,

Jerry Metcalf MPH, CHMM


Sr. Manager, Safety/Environmental
Hilti Inc.
918 872 3704
jerry.metcalf@hilti.com

Rev. Date: 1/27/16

The manufacturing plant location on this certificate has been provided for LEEDS reporting purposes only. It should never be used
for Country of Origin certification or a representation of compliance/non-compliance with Buy American or Buy America
requirements, as those requirements differ.

The manufacturing plant location(s) identified on the certificate represent standard Hilti catalog products only. “Specially” produced
non-catalog Hilti products may have differing manufacturing plant locations.

Contact your Hilti representative in cases of “specially” produced products for a custom LEEDS certificates.

Hilti, Inc.
5400 South 122 n d East Avenue
Tulsa, OK 74146

1-800-879-8000
www.hilti.com
Fire Containment Insulation Thermafiber® Safing™

+ Exceptional performance in Perimeter


Fire Containment Systems

+ Provides life saving fire protection in


rated assemblies

+ F
ire resistant to temperatures above
2,000°F (1,093°C)

+ E
asy to fabricate for through
penetrations and firestopping

+ Conserves energy, reduces


greenhouse gas emissions

+ Resists moisture

+ Controls noise and sound

LEED v2009 Green Building Credits


®

Energy & Materials Indoor Innovation in


Minimum Atmosphere & Resources Environmental Design

70%
Quality
1 2.1, 2.2 9 1
Recycled 4.1, 4.2
Content1 5.1, 5.2
Thermafiber Safing and FireSpan® insulation provide the critical components of
the perimeter fire containment system in the 111 South Wacker Building in Chicago,
IL. Thermafiber insulation also contributed to the building’s LEED® Gold Rating.

Thermafiber® SafingTM is compression fitted between FireSpan® insulation and


the concrete slab edge to create a perimeter fire containment system.
Thermafiber® SafingTM Insulation
THERMAFIBER SafingTM products are designed to provide life saving fire protection in perimeter fire containment
Description: systems, floor and wall penetrations, construction joints, and other firestopping applications. These products are
noncombustible, moisture-resistant, noncorrosive, nondeteriorating, mildew-proof and vermin-proof. Thermafiber Safing
provides thermal insulation, fire protection, and acoustical control in many different UL and Intertek (formerly OPL) listed
fire containment assemblies of 1, 2, and 3-hr ratings.
• Safing 4.0 pcf, 2” or greater thickness, is available with or without a vapor retarding foil facing.
Product Options: • Safing 6.0 pcf, 1.5” or greater thickness, is available with or without a vapor retarding foil facing.
• Recycled Content Options1:
EPA Choice Fiber (US Government Buildings)......... Minimum 75%
Standard Fiber..................................................................... 70%
1
Recycled content options other than Standard must be specified at time of order.

All firestopping insulation should be installed per the architectural specification or system specific test description. All
Installation: compressed Safing insulation should be installed per the listed assembly.
• Perimeter Installation: SafingTM insulation should be compression fitted between the slab edge and the FireSpan
curtain wall insulation, leaving no voids.
• Penetration Application: Safing insulation should be cut slightly larger than the opening and compression fitted into the
opening, leaving no voids.
• Construction Joint Application: Safing insulation should be compression fitted into the joint opening, leaving no voids.

Standard Sizes: Thickness* Widths** Lengths**


Safing 4.0 pcf 1”- 7” 16”, 24”, 36” 48”, 60”
Safing 6.0 pcf 1”- 7” 16”, 24”, 36” 48”, 60”
Tolerances +1/4” - 1/8” ±1/8” ±1/2”
*Thicknesses are available in ½” increments. **Custom sizes are available upon request.

Technical Data: Tested to ASTM E 84


Tested to ASTM C 518 Unfaced Foil Faced
Product Actual “k” @ 75° [24°C] “R” value per Flame Smoke Flame Smoke
Designation Density
BTU.in/hr.sq. ft. °F inch of thickness*** Spread Developed Spread Developed

TF612/Rev 03-15 Copyright 2015, Thermafiber, Inc. All Rights Reserved. LEED® is a registered trademark of U.S. Green Building Council.
Safing 4.0 pcf 0.24 ‘R’= 4.2 0 0 25 0
Safing 6.0 pcf 0.24 ‘R’= 4.2 0 0 25 0
***R = thickness divided by ‘k’

SafingTM insulation is a critical component of any perimeter fire containment system. Thermafiber® has performed decades
Fire-Containment Tests of testing in all of the containment systems listed below. For more complete test information, see SA707, THERMAFIBER
Per ASTM E 2307 Life-Safety Fire Containment Systems technical catalog or UL® and Intertek® (formerly OPL) Directories. For a full listing of
containment systems visit www.thermafiber.com and click on Fire Rated Assemblies. UL Reference = TYPE SAF
• Aluminum Spandrel Curtain Wall Fire Containment
• Steel Stud-Framed/Gypsum Sheathing Curtain Wall Fire Containment
• Glass Spandrel Curtain Wall Fire Containment
• Granite Spandrel Curtain Wall Fire Containment
• Precast Concrete Spandrel

SafingTM Insulation meets the following:


Standards Compliance: ASTM C 665 Non-corrosive, Type I, III
ASTM C 612 Type IA, IB, II
ASTM E 136 Rated Non-combustible per NFPA Standard 220
CAN/ULC S114 Complies
ASTM E 96 Unfaced, 50 Perms as tested
ASTM E 96 Foil Faced, 0.02 Perms as tested
ASTM C 1104 Absorbs less than 1% by volume
CAN/ULC S102 Flame Spread 0, Smoke Developed 0
ASTM E 814 or UL 1479 Safing Insulation used in conjunction with an approved fill, void, or cavity material
sealant or other approved material in through – penetration firestop systems - Complies
UL 2079 Safing Insulation used in conjunction with an approved fill, void or cavity material
in construction joint systems - Complies
CAN/ULC S115 Complies
Safing products are approved by: New York City Board of Standards & Appeals – (under BSA 39-74-SM & accepted by
MEA-209-82-M, Vol. 4).

Thermafiber offers industry leading technical and engineering assistance to architects, specifiers, and contractors.
Thermafiber® Insolutions®: These services include CAD drawings, engineering judgments, LEED® Credit Information, product recommendations,
and customized products. Contact our technical services department at
1-888-834-2371, or email technicalservice@owenscorning.com
For additional information about these or other Thermafiber products contact us at 1-888-834-2371 or visit our
For Further Information: website www.thermafiber.com.
THERMAFIBER, Inc. shall not be liable for incidental and consequential damages, directly or indirectly sustained, nor for any loss caused by application of
Notice: these goods not in accordance with current printed instructions or for other than the intended use. THERMAFIBER liability is expressly limited to replacement of
defective goods. Any claim shall be deemed waived unless made in writing within thirty (30) days from date it was or reasonably should have been discovered.

Submittal Approvals: Job Name

Contractor Date

3711 Mill Street | Wabash, IN 46992 | 888-TFIBER1 [834-2371] | [260] 563-2111 | www.thermafiber.com
CERTIFICATE OF COMPLIANCE
Certificate Number 20151218-R10905
Report Reference R10905
Issue Date 2015-December-18

Issued to: Thermafiber Inc.


3711 Mill St
Wabash, IN 46992 USA

This is to certify that Forming Materials


representative samples of Forming Materials Certified for Canada

Have been investigated by UL in accordance with the


Standard(s) indicated on this Certificate.

Standard(s) for Safety: ANSI/UL 1479, "Fire Tests of Through-Penetration Firestops,"


ANSI/UL 2079, "Tests for Fire Resistance of Building Joint
Systems," and ANSI/ASTM E2307 (2010), "Standard Test
Method for Determining Fire Resistance of Perimeter Fire
Barriers Using Intermediate-Scale, Multi-story Test Apparatus."
CAN/ULC-S115 (2005), "Standard Method of Fire Tests of
Firestop Systems."
Additional Information: See the UL Online Certifications Directory at
www.ul.com/database for additional information

Only those products bearing the UL Certification Mark should be considered as being covered by UL's
Certification and Follow-Up Service.

Look for the UL Certification Mark on the product.

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 1 of 3
CERTIFICATE OF COMPLIANCE
Certificate Number 20151218-R10905
Report Reference R10905
Issue Date 2015-December-18

This is to certify that representative samples of the product as specified on this certificate were tested according to the
current UL requirements.

Type SAF mineral wool batts for use in Joint System Nos. BW-S-0029, FF-D-0002, FF-D-0011, FF-D-0013,
FF-D-0014, FF-D-0015, FF-D-0016, FF-D-0017, FF-D-0019, FF-D-0022, FF-D-0023, FF-D-0025, FF-D-0026,
FF-D-0028, FF-D-0073, FF-D-0074, FF-D-0096, FF-D-0097, FF-D-0109, FF-D-1001, FF-D-1002, FF-D-1003,
FF-D-1004, FF-D-1006, FF-D-1007, FF-D-1008, FF-D-1010, FF-D-1015, FF-D-1016, FF-D-1020, FF-D-1021,
FF-D-1024, FF-D-1025, FF-D-1027, FF-D-1036, FF-D-1039, FF-D-1040, FF-D-1041, FF-D-1042, FF-D-1045,
FF-D-1047, FF-D-1098, FF-D-1125, FF-D-1158, FF-D-3003, FF-D-3004, FF-S-1031, FF-S-1033, FW-D-0001,
FW-D-0004, FW-D-0007, FW-D-0009, FW-D-0010, FW-D-0011, FW-D-0012, FW-D-0014, FW-D-0017, FW-D-0018,
FW-D-0020, FW-D-0021, FW-D-0023, FW-D-0024, FW-D-0027, FW-D-0050, FW-D-0051, FW-D-0067, FW-D-0068,
FW-D-1001, FW-D-1002, FW-D-1003, FW-D-1005, FW-D-1006, FW-D-1007, FW-D-1009, FW-D-1010, FW-D-1016,
FW-D-1017, FW-D-1020, FW-D-1024, FW-D-1033, FW-D-1035, FW-D-1037, FW-D-1038, FW-D-1039, FW-D-1040,
FW-D-1044, FW-D-1047, FW-D-1055, FW-D-1070, FW-D-1089, FW-D-1092, FW-D-1093, FW-D-1102, FW-D-1103
FW-S-1016, FW-S-1019, HW-D-0001, HW-D-0002, HW-D-0006, HW-D-0009, HW-D-0013, HW-D-0016, HW-D-0017,
HW-D-0020, HW-D-0021, HW-D-0022, HW-D-0023, HW-D-0025, HW-D-0026, HW-D-0027, HW-D-0028, HW-D-0029,
HW-D-0030, HW-D-0031, HW-D-0034, HW-D-0038, HW-D-0039, HW-D-0040, HW-D-0042, HW-D-0043, HW-D-0044,
HW-D-0045, HW-D-0046, HW-D-0047, HW-D-0049, HW-D-0050, HW-D-0051, HW-D-0052, HW-D-0054,
HW-D-0055, HW-D-0058, HW-D-0059, HW-D-0062, HW-D-0064, HW-D-0067, HW-D-0069, HW-D-0072,
HW-D-0073, HW-D-0075, HW-D-0079, HW-D-0086, HW-D-0087, HW-D-0088, HW-D-0089, HW-D-0091,
HW-D-0092, HW-D-0099, HW-D-0100, HW-D-0101, HW-D-0102, HW-D-0103, HW-D-0104, HW-D-0105,
HW-D-0106, HW-D-0107, HW-D-0108, HW-D-0118, HW-D-0122, HW-D-0123, HW-D-0127, HW-D-0128,
HW-D-0131, HW-D-0136, HW-D-0137, HW-D-0139, HW-D-0140, HW-D-0143, HW-D-0146, HW-D-0149,
HW-D-0152, HW-D-0153, HW-D-0154, HW-D-0156, HW-D-0157, HW-D-0160, HW-D-0166, HW-D-0168,
HW-D-0170, HW-D-0171, HW-D-0172, HW-D-0173, HW-D-0174, HW-D-0177, HW-D-0178, HW-D-0185,
HW-D-0186, HW-D-0187, HW-D-0188, HW-D-0190, HW-D-0192, HW-D-0199, HW-D-0200, HW-D-0201,
HW-D-0204, HW-D-0205, HW-D-0206, HW-D-0208, HW-D-0211, HW-D-0218, HW-D-0220, HW-D-0221,
HW-D-0222, HW-D-0246, HW-D-0248, HW-D-0252, HW-D-0253, HW-D-0258, HW-D-0259, HW-D-0263,
HW-D-0265, HW-D-0278, HW-D-0279, HW-D-0297, HW-D-0298, HW-D-0299, HW-D-0335, HW-D-0336,
HW-D-0337, HW-D-0338, HW-D-0354, HW-D-0357, HW-D-0358, HW-D-0359, HW-D-0363, HW-D-0365,
HW-D-0366, HW-D-0367, HW-D-0377, HW-D-0378, HW-D-0380, HW-D-0381, HW-D-0384, HW-D-0385,
HW-D-0388, HW-D-0389, HW-D-0391, HW-D-0395, HW-D-0396, HW-D-0404, HW-D-0405, HW-D-0406,
HW-D-0407, HW-D-0408, HW-D-0409, HW-D-0410, HW-D-0411, HW-D-0412, HW-D-0413, HW-D-0414,
HW-D-0415, HW-D-0416, HW-D-0417, HW-D-0441, HW-D-0442, HW-D-0447, HW-D-0456, HW-D-0457,
HW-D-0460, HW-D-0465, HW-D-0467, HW-D-0468, HW-D-0478, HW-D-0479, HW-D-0524, HW-D-0531,
HW-D-0536, HW-D-0538, HW-D-0539, HW-D-0540, HW-D-0542, HW-D-0546, HW-D-0547, HW-D-0548,
HW-D-0549, HW-D-0553, HW-D-0560, HW-D-0561, HW-D-0562, HW-D-0564, HW-D-0566, HW-D-0567,
HW-D-0568, HW-D-0569, HW-D-0570, HW-D-0571, HW-D-0572, HW-D-0577, HW-D-0578, HW-D-0580,

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 2 of 3
CERTIFICATE OF COMPLIANCE
Certificate Number 20151218-R10905
Report Reference R10905
Issue Date 2015-December-18

Type SAF mineral wool batts for use in Joint System Nos. HW-D-0582, HW-D-0583, HW-D-0584, HW-D-0590,
HW-D-0591, HW-D-0597, HW-D-0612, HW-D-0614, HW-D-0617, HW-D-0619, HW-D-0631, HW-D-0633,
HW-D-0634, HW-D-0635, HW-D-0636, HW-D-0639, HW-D-0640, HW-D-0642, HW-D-0643, HW-D-0644,
HW-D-0645, HW-D-0649, HW-D-0650, HW-D-0661, HW-D-0662, HW-D-0687, HW-D-0697, HW-D-0698,
HW-D-0702, HW-D-0703, HW-D-0704, HW-D-0725, HW-D-0726, HW-D-0735, HW-D-0740, HW-D-0741,
HW-D-0742, HW-D-0743, HW-D-0747, HW-D-0748, HW-D-0750, HW-D-1001, HW-D-1002, HW-D-1003,
HW-D-1004, HW-D-1005, HW-D-1006, HW-D-1007, HW-D-1010, HW-D-1013, HW-D-1014, HW-D-1015,
HW-D-1016, HW-D-1020, HW-D-1021, HW-D-1022, HW-D-1023, HW-D-1024, HW-D-1028, HW-D-1032,
HW-D-1033, HW-D-1034, HW-D-1037, HW-D-1040, HW-D-1042, HW-D-1044, HW-D-1045, HW-D-1050,
HW-D-1060, HW-D-1066, HW-D-1067, HW-D-1068, HW-D-1069, HW-D-1070, HW-D-1073, HW-D-1074,
HW-D-1075, HW-D-1076, HW-D-1077, HW-D-1079, HW-D-1080, HW-D-1089, HW-D-1094, HW-D-1097,
HW-D-1102, HW-D-1103, HW-D-1104, HW-D-1110, HW-S-0001, HW-S-0009, HW-S-0010, HW-S-0053,
HW-S-0054, HW-S-0080, HW-S-0083, HW-S-1015, WW-D-0013, WW-D-0018, WW-D-0019, WW-D-0020,
WW-D-0063, WW-D-1001, WW-D-1002, WW-D-0022, WW-D-0089, WW-D-0090, WW-D-0103, WW-D-0171,
WW-D-0140, WW-D-0141, WW-D-1003, WW-D-1004, WW-D-1005, WW-D-1006, WW-D-1007, WW-D-1010,
WW-D-1015, WW-D-1016, WW-D-1023, WW-D-1027, WW-D-1036, WW-D-1037, WW-D-1042, WW-D-1047,
WW-D-1089, WW-D-1090, WW-D-1091, WW-D-1128, WW-D-1129, WW-S-0064, WW-S-1035.

TYPE SAF MINERAL WOOL BATTS FOR USE IN PERIMETER FIRE CONTAINMENT SYSTEM N OS. CW-D-1001, CW-D-1002,
CW-D-1003, CW-D-1004, CW-D-1005, CW-D-1006, CW-D-1007, CW-D-1008, CW-D-1009, CW-D-1010,
CW-D-1011, CW-D-1012, CW-D-1013, CW-D-1014, CW-D-1015, CW-D-1016, CW-D-1017, CW-D-1018,
CW-D-1019, CW-D-1020, CW-D-1021, CW-D-1022, CW-D-1023, CW-D-1028, CW-D-1029, CW-D-1030,
CW-D-2001, CW-D-2002, CW-D-2003, CW-D-2005, CW-D-2006, CW-D-2008, CW-D-2009, CW-D-2010,
CW-D-2011, CW-D-2012, CW-D-2013, CW-D-2036, CW-D-2037, CW-D-2038, CW-D-2039, CW-D-2040,
CW-D-2041, CW-D-2042, CW-D-2046, CW-D-2047, CW-D-2048, CW-D-2049, CW-D-2050, CW-D-2051,
CW-D-2052, CW-D-2055, CW-D-2056, CW-D-2057, CW-D-2058, CW-D-2059, CW-D-2063, CW-D-2064,
CW-D-2065, CW-D-2066, CW-S-0001, CW-S-0002, CW-S-0003, CW-S-0004, CW-S-1001, CW-S-1002,
CW-S-1003, CW-S-1007, CW-S-1010, CW-S-1016, CW-S-1017, CW-S-1020, CW-S-1022, CW-S-1023,
CW-S-1024, CW-S-1025, CW-S-1026, CW-S-2001, CW-S-2002, CW-S-2003, CW-S-2006, CW-S-2008,
CW-S-2014, CW-S-2021, CW-S-2022, CW-S-2023, CW-S-2025, CW-S-2029, CW-S-2034, CW-S-2035,
CW-S-2036, CW-S-2058, CW-S-2059, CW-S-2060, CW-S-2061, CW-S-2062, CW-S-2064, CW-S-2065,
CW-S-2066.

TYPE SAF MINERAL WOOL BATTS FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEM NOS . C-AJ-1020, C-AJ-1081,
C-AJ-3045, W-L-1027, W-L-1039, W-L-1064, W-L-1065, W-L-2023, W-L-2036, W-L-3023, W-L-3034, W-L-7001,
W-L-7002.

TOPSTOP MINERAL WOOL DECK PLUGS TYPE SAF BATTS FOR USE IN JOINT SYSTEM NOS. HW-D-0001, HW-D-0002,
HW-D-0020, HW-D-0022, HW-D-0034, HW-D-0039, HW-D-0043, HW-D-0086, HW-D-0088, HW-D-0160,
HW-D-0161, HW-D-0456, HW-D-0612, HW-D-0644.

Bruce Mahrenholz, Director North American Certification Program

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/

Page 3 of 3
Material Information Statement
Manufactured Articles
According to 1907/2006/EC, Article 32
Revision: 23.04.2019 Version: 14

1 Identification of the manufactured articles and of the company undertaking


1.1 Product identifier

Trade name:

 Firestop Bandage CFS-B / CP 646  Firestop Module Box CFS-MB / CP 657


 Firestop Back Pan Strip CFS-BPS  Firestop Plug CFS-PL / CP 658
 Firestop Block CFS-BL / CFS-BL P  Firestop Plug Seal CFS-T RR / CFS-T RRS
 Firestop Board CP 675  Firestop Retrofit Sleeve CFS-SL RK
 Firestop Boot CFS-BO  Firestop Sleeve CP 645
 Firestop Box Insert  Firestop Sleeve Kit CFS-SL SK
 Firestop Cable Collar CFS-CC / CFS-RCC / CFS-RCC EXT  Firestop Speed Sleeve CFS-SL / CFS-SL GA / CP 653
 Firestop Cable Module CFS-T  Firestop Top Track Seal CFS-TTS
 Firestop Cast-in device CP 680 / CP 681 / CFS-CID /  Firestop Wedge Seal CFS-T WD120
 CFS-CID MD P/M  Firestop Wrap Strip CFS-W EL / SG / P / CP 648
 Firestop Coated Board CFS-CT B / CP670 / CP673 / CP676  Foil Tapes CS-FT
 Firestop Collar CFS-C / CFS-C P  Joint Sealing Tapes CS-JST
 Firestop Collar CP 643 / CP 644  Mineral Wool
 Firestop Composite Sheet CFS-COS  Mineral Wool Boards
 Firestop Cord CFS-CO  Multifunctional Tapes CS-MFT
 Firestop Cushion CP 651N  Pre-coated Mineral Wool Boards
 Firestop Drop-In Device CFS-DID  Smoke & Acoustic Track Seal CS-TTS SA
 Firestop Edge of Slab QuickSeal CFS-EOS QS  Speed Plug CP 777
 Firestop Endless Collar CFS-C EL  Speed Strip CP 767
 Firestop Filler Module CFS-T FB
 Firestop Gangplate CFS-SL GP

1.2 Application of the manufactured articles

Construction industry.
Refer to Hilti product literature, technical data sheets, 3rd party published listings and national approvals for specific application information. For
more details, please contact your local Hilti organization through http://www.hilti.group

1.3 Manufacturer / Supplier

Hilti AG
Feldkircherstr. 100
FL-9494 Schaan
Liechtenstein

Customer Service
Phone +423 (0)844 84 84 85
Fax +423 (0)844 84 84 86

2 Other information
A Safety Data Sheet is not required due to the classification of these products as “manufactured articles” according to Regulation (EC) No.
1907/2006 of 18 December 2006 (EU) / 29CFR 1910.1200 (U.S.A.). Consequently, these products are exempted from CLP / OSHA Labeling and
SDS requirements.

These data are based on our present knowledge. However, they shall not constitute a guarantee for any specific product features and shall not
establish a legally valid contractual relationship.

Informing department:
chemicals.hse@hilti.com
September 24, 2015

To Whom It May Concern:

Re: Hilti Mineral Wool-LEED Information

Item Number:

236993

The Hilti Mineral Wool is manufactured in Wabash, Indiana.

The post-consumer recycled content in the Hilti Mineral Wool is 0%. The pre-consumer recycled content in the Hilti Mineral Wool
is 90%. There is no detectable VOC content in this product.

Hilti Mineral Wool is not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the disposal of non-
regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult your local and
state regulatory agencies for direction on disposal.

Please feel free to contact me at (918) 872-3704 if you have questions.

Sincerely,

Jerry Metcalf MPH, CHMM


Sr. Manager, Safety/Environmental
Hilti Inc.
918 872 3704
jerry.metcalf@hilti.com

Rev. Date: 9/24/15

The manufacturing plant location on this certificate has been provided for LEEDS reporting purposes only. It should never be used
for Country of Origin certification or a representation of compliance/non-compliance with Buy American or Buy America
requirements, as those requirements differ.

The manufacturing plant location(s) identified on the certificate represent standard Hilti catalog products only. “Specially” produced
non-catalog Hilti products may have differing manufacturing plant locations.

Contact your Hilti representative in cases of “specially” produced products for a custom LEEDS certificates.

Hilti, Inc.
5400 South 122 n d East Avenue
Tulsa, OK 74146

1-800-879-8000
www.hilti.com

You might also like