Stopping
Stopping
UL Listings
HW-D-0155 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
HW-D-0218 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
HW-D-0259 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
CP 767
Product Data Sheet for CP 767 and CP 777 Speed Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
UL Certificate of Compliance for CP 767 and CP 777 Speed Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Material Information Statement for Firestop Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
LEED Information for CP 767 Speed Strips and CP 777 Speed Plugs . . . . . . . . . . . . . . . . . . . . . . . . 33
CP 777
Product Data Sheet for CP 767 and CP 777 Speed Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
UL Certificate of Compliance for CP 767 and CP 777 Speed Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Material Information Statement for Firestop Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
LEED Information for CP 767 Speed Strips and CP 777 Speed Plugs . . . . . . . . . . . . . . . . . . . . . . . . 37
Mineral wool
Product Data Sheet for Mineral Wool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
UL Certificate of Compliance for Mineral Wool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Material Information Statement for Firestop Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
LEED Information for Mineral Wool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
S IFI
HWD 0155
AS
System No. HW-D-0155
CL
ED
C US Assembly Rating — 2 Hr
Classified by
Underwriters Laboratories, Inc.
Nominal Joint Width—3/4 In.
to UL 2079 and CAN/ULC-S115 L Rating At Ambient — Less Than 1 CFM/Lin Ft
L Rating At 400°F — Less Than 1 CFM/Lin Ft
Class II Movement Capabilities—17% Compression Or Extension
1B 1A 1B
A 3C
1A
3A
A
2
SECTION A-A
1. Floor Assembly — The fire-rated fluted steel floor unit/concrete floor assembly shall be constructed of the materials and in the manner described
in the individual D900 Floor-Ceiling Design in the Fire Resistance Directory and shall include the following construction features:
A. Steel Floor and Form Units* — Max 2 in. (51 mm) deep galv steel fluted floor units.
B. Concrete — Min 2-1/2 in. (64 mm) thick reinforced concrete, as measured from the top plane of the floor units.
1A. Roof Assembly — (Not Shown) — As an alternate to the floor assembly, a fire rated fluted steel deck roof assembly may be used. The roof
assembly shall be constructed of the materials and in the manner described in the individual P900 Series Roof-Ceiling Design in the UL Fire
Resistance Directory. The hourly rating of the roof assembly shall be equal to or greater than the hourly rating of the wall assembly. The roof
assembly shall include the following construction features:
A. Steel Roof Deck — Max 3 in. (76 mm) deep galv steel fluted roof deck.
B. Roof Insulation — Min 2-1/4 in. (57 mm) thick poured insulating concrete, as measured from the top plane of the floor units.
2. Wall Assembly — Min 5 in. (127 mm) thick steel reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. Wall may
also be constructed of an UL Classified Concrete Blocks*.
See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufactures.
HWD 0155
AS
System No. HW-D-0155
CL
ED
C US Assembly Rating — 2 Hr
Classified by
Underwriters Laboratories, Inc.
Nominal Joint Width—3/4 In.
to UL 2079 and CAN/ULC-S115 L Rating At Ambient — Less Than 1 CFM/Lin Ft
L Rating At 400°F — Less Than 1 CFM/Lin Ft
Class II Movement Capabilities—17% Compression Or Extension
See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufactures.
3. Joint System — Max separation between bottom of floor or roof and top of wall is 3/4 in. (19 mm). The joint system is designed to accommodate a
max 17 percent compression or extension from its installed width. The joint system consists of a forming material and a fill material between the
top of the wall and the bottom of the floor or roof, as follows:
A. Forming Material* — Nom 4 pcf (64 kg/m3) density mineral wool batt insulation cut approx 20 percent wider than the flutes, with a length
approx equal to the overall thickness of the wall. Pieces stacked as needed and then compressed 20 percent in thickness and inserted into
the flutes of the steel deck. The mineral wool batt insulation shall be recessed 1/4 in. (6 mm) from wall surfaces. Additional nom 4 pcf (64
kg/m3) mineral wool batt insulation shall be cut into strips to fill the gap between the top of the wall and bottom of the steel deck. The width of
the strips shall be equal to the total thickness of the wall less 1/2 in. The strips of mineral wool are compressed 50 percent in thickness and
firmly packed into the gap between the top of the wall and bottom of the steel deck, recessed 1/4 in. (6 mm) ffrom wall surfaces.
FIBREX INSULATIONS INC — FBX Safing Insulation
A1. Forming Material*—Plugs — (Optional-Not Shown) Performed mineral wool plugs, formed to the shape of the fluted floor units, friction fit to
completely fill the flutes. The plugs shall be recessed 1/4 in. (6 mm) from both wall surfaces. Additional forming material, described in Item 3A,
to be used in conjunction with the plugs to fill the gap between the top of the wall and bottom of steel floor units.
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP777 Speed Plugs
B. Fill, Void or Cavity Material* - Sealant — Min 1/4 in. (6 mm) thickness of fill material installed on each side of the wall in the flutes of the steel
deck between the top of the wall and the bottom of the steel deck, flush with each surface of the wall.
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP606 Flexible Firestop Sealant
*Bearing the UL Classification Mark
ED
C US
Classified by ANSI/UL2079 CAN/ULC S115
Underwriters Laboratories, Inc.
to UL 1479 and CAN/ULC-S115 Assembly Ratings — 1 and 2 Hr (See Item 2) F Ratings — 1 and 2 Hr (See Item 2)
Nominal Joint Width - 1-1/2 In. FT Ratings — 1 and 2 Hr (See Item 2)
Class II Movement Capabilities — 25% Compression or
FH Ratings — 1 and 2 Hr (See Item 2)
Extension
L Rating At Ambient — Less Than 1 CFM/lin ft FTH Ratings — 1 and 2 Hr (See Item 2)
L Rating At 400 F — Less Than 1 CFM/lin ft Nominal Joint Width - 1-1/2 In.
Class II Movement Capabilities — 25% Compression or
Extension
L Rating At Ambient — Less Than 1 CFM/lin ft
L Rating At 400 F — Less Than 1 CFM/lin ft
1A 1B 1A 1B
A
1E
2A
3A
1C
1E 1C 3B 1D
3A
2B 2C
3B A 2C 2B SECTION A-A
1. Floor Assembly — The fire-rated fluted steel floor unit/concrete floor assembly shall be constructed of the materials and in the manner
described in the individual D700 or D900 Series Floor-Ceiling Design in the Fire Resistance Directory and shall include the following
construction features:
A. Steel Floor and Form Units* — Max 3 in. (76 mm) deep galv steel fluted floor units.
B. Concrete — Min 2-1/2 in. (64 mm) thick reinforced concrete, as measured from the top plane of the floor units.
C. Structural Steel Support (Optional) - Steel beam or open-web steel joist, as specified in the individual D700 or D900 Series Floor-Ceiling
Design, used to support steel floor units. Structural steel support oriented perpendicular to wall assembly. — Steel beam or open-web steel
joist, as specified in the individual D700 or D900 Series Floor-Ceiling Design, used to support steel floor units. Structural steel support
oriented perpendicular to wall assembly.
D. Steel Lath — Where open-web steel joists pass through the fire rated wall, 3/8 in. diamond mesh expanded steel lath having a nom weight
of 1.7 to 3.4 lb per sq yd (0.9 to 1.8 kg/m2) shall be secured to one side of each joist with steel tie wire and the lath shall be fully covered
with no min thickness requirement.
E. Spray-Applied Fire Resistive Material* — After the installation of the ceiling runner, (Item 2A, 2A1 or 2A2) steel floor units to be sprayed
with the thickness of material specified in the individual D700 Series Design or the structural steel supports to be sprayed in accordance
with the specifications in the individual D900 Series Design. Material is to be excluded from the steel floor units, directly above the gypsum
board and from the flanges of the ceiling runners.
ISOLATEK INTERNATIONAL — Type 300
GCP APPLIED TECHNOLOGIES INC — Types MK-6/HY or MK-10HB
1A. Roof Assembly — (Not Shown) — As an alternate to the floor assembly, a fire rated fluted steel deck roof assembly may be used. The
roof assembly shall be constructed of the materials and in the manner described in the individual P700 or P900 Series Roof-Ceiling Design
in the UL Fire Resistance Directory. The hourly rating of the roof assembly shall be equal to or greater than the hourly rating of the wall
assembly. The roof assembly shall include the following construction features as applicable:
A. Steel Roof Deck — Max 3 in. (76 mm) deep galv steel fluted roof deck.
B. Roof Insulation — Min 2-1/4 in. (57 mm) thick poured insulating concrete, as measured from the top plane of the steel roof deck.
C. Structural Steel Support — (Optional) - Steel beam or open-web steel joist, as specified in the individual P700 or P900 Series Roof-Ceiling
Design, used to support steel roof deck. Structural steel support oriented perpendicular to wall assembly. Steel beam or open-web steel
joist, as specified in the individual P700 or P900 Series Roof-Ceiling Design, used to support steel roof deck. Structural steel support
oriented perpendicular to wall assembly.
D. Steel Lath — Where open-web steel joists pass through the fire rated wall, 3/8 in. diamond mesh expanded steel lath having a nom weight
of 1.7 to 3.4 lb per sq yd (0.9 to 1.8 kg/m2) shall be secured to one side of each joist with steel tie wire and the lath shall be fully covered
with no min thickness requirement.
E. Spray-Applied Fire Resistive Material* — After the installation of the ceiling runner, (Item 2A, 2A1 or 2A2) steel roof deck to be sprayed
with the thickness of material specified in the individual P700 Series Design or the structural steel supports to be sprayed in accordance
with the specifications in the individual P700 or P900 Series Design. Material is to be excluded from the steel roof deck, directly above the
gypsum board and from the flanges of the ceiling runners.
ISOLATEK INTERNATIONAL — Type 300
GCP APPLIED TECHNOLOGIES INC — Types MK-6/HY or MK-10HB
2. Wall Assembly* — The 1 or 2 h fire-rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner specified
in the individual U400 or V400 Series Wall and Partition Design in the UL Fire Resistance Directory and shall include the following construction
features:
A. Steel Floor and Ceiling Runners — Floor and ceiling runners of wall assembly shall consist of min No. 25 gauge galv steel channels sized
to accommodate steel studs (Item 2B). Flange height of ceiling runner shall be min 1/4 in. (6 mm) greater than max extended joint width.
Ceiling runner centered beneath and parallel with valley of steel floor units (Item 1A). Ceiling runner secured to steel floor units with
masonry anchors, steel fasteners or welds spaced max 24 in. (610 mm) OC. A clearance of 1-1/2 in. (38 mm) shall be maintained between
the ceiling runner and the spray-applied fire resistive material on the structural steel support members.
A1 Light Gauge Framing*-Slotted Ceiling Runner — As an alternate to the ceiling runner in Item 2A, slotted ceiling runner to consist of galv
steel channel with slotted flanges sized to accommodate steel studs (Item 2B). Slotted ceiling runner installed parallel to direction of fluted
steel deck, centered beneath valley, prior to the application of spray-applied fire resistive material, and secured with steel masonry anchors,
steel fasteners or welds spaced max 24 in. (610 mm) OC.
BRADY CONSTRUCTION INNOVATIONS INC, DBA SLIPTRACK SYSTEMS — SLP-TRK, SLPTRK325
CALIFORNIA EXPANDED METAL PRODUCTS CO — CST
CLARKDIETRICH BUILDING SYSTEMS — Types SLT, SLT-H
MARINO/WARE, DIV OF WARE INDUSTRIES INC — Type SLT
RAM SALES L L C — RAM Slotted Track
SCAFCO STEEL STUD MANUFACTURING CO
TELLING INDUSTRIES L L C — True-Action Deflection Track
A2. Light Gauge Framing*-Vertical Deflection Ceiling Runner — As an alternate to the ceiling runners in Item 2A and 2A1, vertical deflection
ceiling runner to consist of galv steel channel with slotted vertical deflection clips mechanically fastened within runner. Slotted clips,
provided with step bushings, for permanent fastening of steel studs. Flanges sized to accommodate steel studs (Item 2B). Vertical
deflection ceiling runner installed parallel to direction of fluted steel deck, centered beneath valley, prior to the application of spray-applied
fire resistive material, and secured with steel masonry anchors, steel fasteners or welds spaced max 24 in. (610 mm) OC.
* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada),
respectively.
HWD0259
AS
CL
System No. HW-D-0259
ED
C US
ANSI/UL2079 CAN/ULC S115
Classified by
Underwriters Laboratories, Inc. Assembly Ratings — 1 and 2 Hr (See Items 1 and 2) F Ratings — 1 and 2 Hr (See Items 1 and 2)
to UL 2079 and CAN/ULC-S115
Nominal Joint Width - 1-1/2 In. FT Ratings — 1 and 2 Hr (See Items 1 and 2)
Class II Movement Capabilities — 50% Compression or
FH Ratings — 1 and 2 Hr (See Items 1 and 2)
Extension
L Rating At Ambient — Less Than 1 CFM/lin ft FTH Ratings — 1 and 2 Hr (See Items 1 and 2)
L Rating At 400 F — Less Than 1 CFM/lin ft Nominal Joint Width - 1-1/2 In.
Class II Movement Capabilities — 50% Compression or
Extension
L Rating At Ambient — Less Than 1 CFM/lin ft
L Rating At 400 F — Less Than 1 CFM/lin ft
1A 1B SECTION A-A
A
1C
1D
3B
3A 2
1. Floor Assembly — The fire-rated fluted steel floor unit/concrete floor assembly shall be constructed of the materials and in the manner described
in the individual Floor-Ceiling Design in the Fire Resistance Directory and shall include the following construction features:
A. Steel Floor and Form Units* — Max 3 in. (76 mm) deep galv steel fluted floor units.
B. Concrete — Min 2-1/2 in. (64 mm) thick reinforced concrete, as measured from the top plane of the floor units.
C. Structural Steel Support — Steel beam, as specified in the individual D700 or D900 Series Floor-Ceiling Design, used to support steel floor
units. Structural steel support centered over and parallel with wall assembly.
D. Spray-Applied Fire Resistive Material* — Steel floor units and structural steel beam to be sprayed with the thickness of material specified in
the individual D700 Series Design or the structural steel supports to be sprayed in accordance with the specifications in the individual D900
Series Design. The flutes of the steel floor units are to be filled with material across the entire top flange of the steel beam. Additional material
shall be applied to the web of the steel beam on each side of the wall. For a 1 hr Assembly Rating, the total thickness of material applied to
each side of the steel beam web shall be min 13/16 in. (21 mm). For a 2 hr Assembly Rating, the total thickness of material applied to each
side of the steel beam web shall be min 1-3/8 in. (35 mm).
GCP APPLIED TECHNOLOGIES INC — Types MK-6-HY or MK-10HB
D1. Spray-Applied Fire Resistive Material* — Steel floor units and structural steel support to be sprayed with the min thickness of material
specified in the individual D700 or D900 Series Design. The flutes of the steel floor units are to be filled with material across the entire top
flange of the steel beam. Additional material shall be applied to the web of the steel beam on each side of the wall. For a 1 hr Assembly
Rating, the total thickness of material applied to each side of the steel beam web shall be min 11/16 in. (18 mm). For a 2 hr Assembly Rating,
the total thickness of material applied to each side of the steel beam web shall be min 1-1/2 in. (38 mm).
ISOLATEK INTERNATIONAL — Type 300
2. Wall Assembly* — The 1 or 2 h fire rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner specified in
the individual U400, V400 or W400 Series Wall and Partition Design in the UL Fire Resistance Directory and shall include the following
construction features:
A. Steel Floor and Ceiling Runners — Floor and ceiling runners of wall assembly shall consist of min No. 25 gauge galv steel channels sized to
accommodate steel studs (Item 2B). Flange height of ceiling runner shall be min 1/4 in. (6 mm) greater than max extended joint width. Ceiling
runner centered beneath and parallel with steel beam (Item 1C). Ceiling runner secured to steel beam through spray-applied fire resistive
material with steel fasteners spaced max 24 in. (610 mm) OC.
A1. Light Gauge Framing* — Slotted Ceiling Runner As an alternate to the ceiling runner in Item 2A, slotted ceiling runner to consist of galv
steel channel with slotted flanges sized to accommodate steel studs (Item 2B). Slotted ceiling runner centered beneath and parallel with steel
beam (Item 1C). Slotted ceiling runner secured to steel beam with steel fasteners, steel fasteners or welds spaced max 24 in. (610 mm) OC.
BRADY CONSTRUCTION INNOVATIONS INC, DBA SLIPTRACK SYSTEMS — SLP-TRK, SLPTRK325
CALIFORNIA EXPANDED METAL PRODUCTS CO — CST
CLARKDIETRICH BUILDING SYSTEMS — Type SLT, SLT-H
MARINO/WARE, DIV OF WARE INDUSTRIES INC — Type SLT
RAM SALES L L C — RAM Slotted Track
SCAFCO STEEL STUD MANUFACTURING CO
TELLING INDUSTRIES L L C — True-Action Deflection Track
A2. Light Gauge Framing* — Vertical Deflection Ceiling Runner As an alternate to the ceiling runners in Item 2A and 2A1, vertical deflection
ceiling runner to consist of galv steel channel with slotted vertical deflection clips mechanically fastened within runner. Slotted clips, provided
with step bushings, for permanent fastening of steel studs. Flanges sized to accommodate steel studs (Item 2B). Vertical deflection ceiling
runner centered beneath and parallel with steel beam (Item 1C). Vertical Deflection ceiling runner secured to steel beam with steel fasteners,
steel fasteners or welds spaced max 24 in. (610 mm) OC.
A3. Light Gauge Framing*- Notched Ceiling Runner — As an alternate to the ceiling runners in Items 2A through 2A2, notched ceiling runners to
consist of C-shaped galv steel channel with notched return flanges sized to accommodate steel studs (Item 2B). Notched ceiling runner
installed perpendicular to direction of fluted steel deck and secured to valleys with steel masonry anchors, steel fasteners or welds spaced
max 24 in. (610 mm) OC.
OLMAR SUPPLY INC — Type SCR
A4. Light Gauge Framing* — Slotted Ceiling Runner — As an alternate to the ceiling runner in Item 2A through 2A3, ceiling runner to consist of
galv steel channel with slotted flanges sized to accommodate steel studs (Item 2B). Flange height of slotted ceiling runner shall be 3-1/4 in.
(83 mm) with 2 in. (51 mm) deep slots. Slotted ceiling runner centered beneath and parallel with steel beam (Item 1C). Slotted ceiling runner
secured to steel beam with steel fasteners or welds spaced max 24 in. (610 mm) OC.
SCAFCO STEEL STUD MANUFACTURING CO — Slotted Track-Type SDLT
B. Studs — Steel studs to be min 3-1/2 in. (89 mm) wide. Studs cut 3/4 in. to 1-1/4 in. (19 to 32 mm) less in length than assembly height with
bottom nesting in, resting on and fastened to the floor runner and with top nesting in ceiling runner without attachment. When slotted ceiling
runner (Item 2A1) is used, steel studs secured to slotted ceiling runner with No. 8 by 1/2 in. (13 mm) long wafer head steel screws at
midheight of slot on each side of wall. When vertical deflection runner (Item 2A2) is used, studs secured to vertical clip through slip bushing,
supplied, with No.8 by 1/2 in. (13 mm) steel screws at mid-height of slot of each slot. Stud spacing not to exceed 24 in. (610 mm) OC. When
slotted ceiling runner (Item 2A4) is used, steel studs cut in lengths 3/4 to 1-3/4 in. (19 to 44 mm) less than floor to ceiling height and secured
to slotted ceiling runner with No. 8 by 1/2 (13 mm) long wafer head steel screws at +/- 3/16 in. (5 mm) of the mid-height of slot on each side of
wall.
C. Gypsum Board* — 5/8 in. (16 mm) thick, 4 ft (1.22 m) wide with square or tapered edges. The gypsum board type, number of layers an sheet
orientation shall be as specified in the individual U400 or V400 Series Design in the Fire Resistance Directory, except that a max 1-1/2 in. (38
mm) gap shall be maintained between top edge of the gypsum board and the spray applied fire resistive material on the structural steel
support. The top row of screws shall be installed into the studs 1-1/2 in. (38 mm) below the bottom of the ceiling runner.
D. Steel Attachment Clips — (Optional - Not Shown) - As an alternate to steel fasteners, ceiling runner secured to steel beam with Z-shaped
clips formed from min 1 in. (25 mm) long strips of min 20 ga galv steel. Length of clips should not exceed the width (thickness) of the wall.
Clips to be sized to extend through the thickness of the spray-applied fire-resistive material on the bottom flange of the steel beam with 1-1/2
or 2 in. (38 or 51 mm) long upper and lower legs. Legs of clips fastened to bottom of beam (prior to application of spray-applied fire-resistive
materials) and top of ceiling runner with steel fasteners or welds. Clips spaced max 24in. (610 mm) OC.
The hourly ratings of the joint system are dependent on the hourly rating of the wall.
3. Joint System — Max separation between bottom of spray-applied fire resistive material on beam and top of gypsum board at time of installation is
1-1/2 in. (38 mm). The joint system is designed to accommodate a max 50 percent compression or extension from its installed width. The joint
system consists of a forming material and a fill material between the top of the gypsum board and the bottom of the spray-applied fire resistive
material on the beam, as follows:
A. Forming Material* — Nominal 4 pcf (64 kg/m3) mineral wool forming material cut into strips to fill the gap between top of the gypsum board
and bottom of beam. Width of the strips shall be equal to the total thickness of the gypsum board. The strips of mineral wool shall be
compressed 50 percent in thickness and firmly packed into the gap between the top of gypsum board and bottom of beam.
ROCK WOOL MANUFACTURING CO — Delta Board
ROCKWOOL — SAFE
THERMAFIBER INC — Type SAF
A1. Forming Material* - Strips — (Optional) - Nom 5/8 in. (16 mm) and 1-1/4 in. (32 mm) wide by 2 in. (51 mm) high precut mineral wool strips
for 1 and 2 hr rated assemblies respectively. The strips are compressed 50 percent and firmly packed, cut edge first, into the gap between the
top of the gypsum board and bottom of the steel floor units on both sides of the wall.
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP 767 Speed Strips
B. Fill, Void or Cavity Material* — Min 1/16 in. (1.6 mm) dry thickness (min 1/8 in. or 3.2 mm wet thickness) of fill material sprayed or troweled
on each side of wall to completely cover mineral wool forming material and to overlap 1/2 in. (13 mm) onto gypsum board and 2 in. (51 mm)
onto spray-applied fire resistive material on the structural steel support.
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP672 Firestop Spray or CFS-SP WB Firestop Joint Spray
* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada),
respectively.
Introduction
Product description
■■ A sprayable fire-rated mastic for construction joints where
maximum movement is required
Product features
■■ Sprayable or apply by brush
■■ Maximum flexibility, meets 500 cycle requirements (Class II and III
Approval) (ASTM E 1966 and UL 2079) )LUHVWRS
■■ Quick and easy installation with the Titan 600 or 1100 Sprayers
6\VWHP
Selector Guide
For use with Average volume shrinkage 51.1%
■■ Concrete, masonry and gypsum wall assemblies (ASTM C1241)
■■ Wall and floor/wall assemblies rated up to 4 hours Ph-value Approx. 8-9
Movement capability Up to 50%
Examples Surface burning characteristics Flame spread: 15
■■ Where a gypsum wall assembly meets the underside of a metal or (CAN/ULC-S102) Smoke development: 10
concrete deck
Sound transmission classification 59
■■ Where a concrete floor assembly meets with non-rated exterior (ASTM E 90-99) (per tested construction type)
wall (concrete, glass, etc.) Tested in accordance with
■■ Where two concrete floor/wall assemblies meet • UL 2079 • ASTM E 1966 • ASTM E 84 • ASTM E 2837
Through-Penetration
• UL 1479 • ASTM E 814 • ASTM E 2307
*At 73°F (23°C) and 50% relative humidity
**Gray color requires six (6) weeks lead time
Joint
• Instructions below are general guidelines — always rating. 4. Curing time: Allow approx. 24 hours for typical
refer to the applicable drawing in the UL Fire 3. Application of Firestop Joint Spray: Apply Firestop application thickness (@ 73°F / 23°C) 50% humidity
Resistance Directory or Hilti Firestop Systems Guide Joint Spray to the required depth in order to obtain for 1/8" depth for the Firestop Joint Spray to fully
for complete installation information the desired rating. Make sure Firestop Joint Spray cure.
contacts all surfaces and overlaps beyond all 5. Identification: For maintenance reasons all Firestop
Opening surrounding surfaces (Refer to UL System). Titan Joint Spray applications can be permanently marked
1. Clean the opening. Surfaces to which Firestop Joint Sprayers have been successful in applying Firestop with an identification plate and fastened in a visible
Spray will be applied should be cleaned of loose Joint Spray. Hilti recommends the use of the Titan position next to the seal.
debris, dirt, oil, wax and grease. The surface should 600 (for application temperatures above 50°F) or
be moisture and frost free. Not for use
Reference Data
Only those products bearing the UL Certification Mark should be considered as being covered by UL's
Certification and Follow-Up Service.
UL LLC
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
Page 1 of 1
CFS-SP WB; CP 672
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
Date of issue: 11/07/2017 Revision date: 11/07/2017 Supersedes: 12/12/2016 Version: 4.3
SECTION 1: Identification
1.1. Identification
Product form Mixture
Trade name CFS-SP WB; CP 672
Product code BU Fire Protection
Chemical structure
1.2. Relevant identified uses of the substance or mixture and uses advised against
Use of the substance/mixture Flexible joint spray
GHS08
Signal word (GHS-US) Warning
Hazard statements (GHS-US) H361 - Suspected of damaging fertility or the unborn child.
Precautionary statements (GHS-US) P280 - Wear protective gloves/protective clothing/eye protection/face protection.
P308+P313 - If exposed or concerned: Get medical advice/attention.
3.2. Mixtures
- Overland transport
- Transport by sea
No data available
- Air transport
No data available
- Rail transport
Carriage prohibited (RID) No
14.7. Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code
EU-Regulations
No additional information available
National regulations
No additional information available
California Proposition 65 - This product contains, or may contain, trace quantities of a substance(s) known to the
state of California to cause cancer, developmental and/or reproductive harm
NFPA health hazard 0 - Materials that, under emergency conditions, would offer
no hazard beyond that of ordinary combustible materials.
NFPA fire hazard 0 - Materials that will not burn under typical dire conditions,
including intrinsically noncombustible materials such as
concrete, stone, and sand.
NFPA reactivity 0 - Material that in themselves are normally stable, even
under fire conditions.
Hazard Rating
Health 0 Minimal Hazard - No significant risk to health
Flammability 0 Minimal Hazard - Materials that will not burn
Physical 0 Minimal Hazard - Materials that are normally stable, even under fire conditions, and will NOT
react with water, polymerize, decompose, condense, or self-react. Non-Explosives.
Personal protection B
B - Safety glasses, Gloves
Indication of changes:
Section Changed item Change Comments
U.S. - California - Proposition Added
65 - Developmental Toxicity
U.S. - California - Proposition Added
65 - Carcinogens List
Display TSCA summary in 15.1 Added
S_US_Hilti
This information is based on our current knowledge and is intended to describe the product for the purposes of health, safety and
environmental requirements only. It should not therefore be construed as guaranteeing any specific property of the product
Item Numbers:
430792
430793
430802
There is no post-consumer or post-industrial content in CFS-SP WB Firestop Joint Spray and it cannot be recycled. The CFS-SP
WB does not contain any Rapidly Renewable Materials.
CFS-SP WB Firestop Joint Spray is not regulated as hazardous waste by the Federal EPA Standards. The regulations for the
disposal of non-regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult
your local and state regulatory agencies for direction on disposal.
Sincerely,
The manufacturing plant location on this certificate has been provided for LEEDS reporting purposes only. It should never be used
for Country of Origin certification or a representation of compliance/non-compliance with Buy American or Buy America
requirements, as those requirements differ.
The manufacturing plant location(s) identified on the certificate represent standard Hilti catalog products only. “Specially” produced
non-catalog Hilti products may have differing manufacturing plant locations.
Contact your Hilti representative in cases of “specially” produced products for a custom LEEDS certificates.
Hilti, Inc.
5400 South 122 n d East Avenue
Tulsa, OK 74146
1-800-879-8000
www.hilti.com
Product Information
Introduction
Product description
■■ An acrylic based firestop sealant that provides movement
capability in fire rated joints and seals through-penetrations
applications
Product features
■■ Silicone free
■■ Halogen, asbestos and solvent free
■■ Paintable
Selector Guide
■■ Cable bundles Temperature resistance –22°F to 176°F (–30°C to 80°C)
■■ HVAC penetrations Surface burning characteristics Flame Spread: 10
(ASTM E 84-96) Smoke Development: 0
For use with Sound transmission classification 56
■■ Various base materials such as masonry, concrete, gypsum, etc. (ASTM E 90-99) (Relates to specific construction)
■■ Wall and floor assemblies rated up to 3 hours Tested in accordance with
• UL 2079 • ASTM E 814 • ASTM E 1966
Examples • ASTM E 84 • UL 1479 • ASTM G21
■■ Where a gypsum wall assembly meets the underside of a metal or
*At 73°F (23°C) and 50% relative humidity
concrete deck
Through-Penetration
■■ Sealing expansion joints to impede the passage of fire, smoke and
FILL, VOID OR CAVITY MATERIAL
toxic fumes FOR USE IN THROUGH-PENETRATION
FM
■■ Sealing around HVAC penetrations through fire-rated assemblies FIRESTOP SYSTEMS AND
JOINT SYSTEMS
SEE UL FIRE RESISTANCE DIRECTORY $33529('
66Y7 )RU3HQHWUDWLRQ)LUH6WRSV
&RQVXOWWKH)DFWRU\0XWXDO5HVHDUFK&RUSRUDWLRQ$SSURYDO*XLGH
Joint
JOINT
Opening
1. Clean the opening. Surfaces to which CP 606 will
be applied should be cleaned of loose debris, dirt, 1. Clean opening 2. Insert backing 3. Apply CP 606 4. Smooth CP 606 5. Fasten identification
oil, wax and grease. The surface should be moisture material compressed plate (if required)
per UL System FILL, VOID OR CAVITY MATERIALS
and frost free.
CLASSIFIED BY
UNDERWRITERS LABORATORIES, INC.
Application of firestop FOR USE IN TROUGH-PENETRATION
2. Insert fill of mineral wool or backer (as required). R FIRESTOP SYSTEMS
DUCT
66Y7
4. Smooth firestop sealant with a trowel before the skin
forms. Once cured, CP 606 can only be removed Firestop
mechanically.
System
5. For maintenance reasons, a penetration seal can be 1. Clean opening 2. Insert backing 3. Apply CP 606 4. Smooth CP 606 5. Fasten identification
material plate (if required)
Only those products bearing the UL Certification Mark should be considered as being covered by UL's
Certification and Follow-Up Service.
UL LLC
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
Page 1 of 1
Hilti Firestop Acrylic Sealant CFS-S ACR; CP 606
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
Date of issue: 01/07/2016 Revision date: 01/07/2016 Supersedes: 01/07/2016 Version: 4.2
SECTION 1: Identification
1.1. Identification
Product form Mixture
Name Hilti Firestop Acrylic Sealant CFS-S ACR; CP 606
Product code BU Chemicals
Chemical structure
1.2. Relevant identified uses of the substance or mixture and uses advised against
No additional information available
3.2. Mixture
Full text of H-statements: see section 16
4.2. Most important symptoms and effects, both acute and delayed
No additional information available
4.3. Indication of any immediate medical attention and special treatment needed
No additional information available
14.1. UN number
Not regulated for transport
IMDG
Transport hazard class(es) (IMDG) Not applicable
IATA
Transport hazard class(es) (IATA) Not applicable
ADN
Transport hazard class(es) (ADN) Not applicable
RID
- Overland transport
- Transport by sea
No data available
- Air transport
No data available
- Rail transport
Carriage prohibited (RID) No
14.7. Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code
EU-Regulations
No additional information available
National regulations
No additional information available
SDS_US_Hilti
This information is based on our current knowledge and is intended to describe the product for the purposes of health, safety and
environmental requirements only. It should not therefore be construed as guaranteeing any specific property of the product
The CP 606 pail is made of polyethylene and can be completely recycled. There is no post-
consumer or post-industrial content in CP 606 and it cannot be recycled. The CP 606 does not
contain any Rapidly Renewable Materials. The VOC content for CP 606 is 71.0 grams/liter.
CP 606 is not regulated as a hazardous waste by the Federal EPA Standards. The regulations for
the disposal of non-regulated industrial waste can vary from state to state and even city to city.
For this reason, you should consult your local and state regulatory agencies for direction on
disposal.
Sincerely,
Hilti, Inc.
5400 South 122 n d East Avenue
Tulsa, OK 74146
1-800-879-8000
www.hilti.com
Product Information
Product features
• Pre-cut to industry standard size decking flutes
• Reduces material waste
• 3 sizes available
• Pre-cut — leaves no gaps or voids
• Smooth surface provides cost effective spray coverage
• Safer to use — no asbestos
• Up to 60% faster than castle cutting!
• CP 767: 4 PCF Density
• CP 777: 6 PCF Density
Areas of application
• Top-of-wall
Installation instructions
• See Hilti literature or third-party listings for complete application and installation
details
Flute Dimensions
Description Qty Item No.
(L x (Flute) x H)
Hilti Firestop
Saving lives
through innovation
and education
CERTIFICATE OF COMPLIANCE
Certificate Number 20160829-R13081
Report Reference R13081
Issue Date 2016-August-29
Standard(s) for Safety: ANSI/UL 2079, "Tests for Fire Resistance of Building Joint
Systems."
CAN/ULC-S115, "Standard Method of Fire Tests of Firestop
Systems."
Additional Information: See the UL Online Certifications Directory at
www.ul.com/database for additional information
Only those products bearing the UL Certification Mark should be considered as being covered by UL's
Certification and Follow-Up Service.
UL LLC
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
Page 1 of 1
Material Information Statement
Manufactured Articles
According to 1907/2006/EC, Article 32
Revision: 23.04.2019 Version: 14
Trade name:
Construction industry.
Refer to Hilti product literature, technical data sheets, 3rd party published listings and national approvals for specific application information. For
more details, please contact your local Hilti organization through http://www.hilti.group
Hilti AG
Feldkircherstr. 100
FL-9494 Schaan
Liechtenstein
Customer Service
Phone +423 (0)844 84 84 85
Fax +423 (0)844 84 84 86
2 Other information
A Safety Data Sheet is not required due to the classification of these products as “manufactured articles” according to Regulation (EC) No.
1907/2006 of 18 December 2006 (EU) / 29CFR 1910.1200 (U.S.A.). Consequently, these products are exempted from CLP / OSHA Labeling and
SDS requirements.
These data are based on our present knowledge. However, they shall not constitute a guarantee for any specific product features and shall not
establish a legally valid contractual relationship.
Informing department:
chemicals.hse@hilti.com
January 27, 2016
Re: Hilti CP767 Speed Strips and CP777 Speed Plugs – LEED Information
Item Numbers:
CP 767 CP 777
374505 340998
374506 340999
374507 371925
374508
The Hilti CP767 Speed Strips and CP777 Speed Plugs are manufactured in North Carolina.
Post-consumer recycled content of Hilti CP767 Speed Strips and CP777 Speed Plugs is 0%. Pre-consumer recycled content of
Hilti CP767 Speed Strips and CP777 Speed Plugs is 0%. There is no detectable VOC content either product.
Hilti CP767 Speed Strips and CP777 Speed Plugs are not regulated as a hazardous waste by the Federal EPA Standards. The
regulations for the disposal of non-regulated industrial waste can vary from state to state and even city to city. For this reason, you
should consult your local and state regulatory agencies for direction on disposal.
Sincerely,
The manufacturing plant location on this certificate has been provided for LEEDS reporting purposes only. It should never be used
for Country of Origin certification or a representation of compliance/non-compliance with Buy American or Buy America
requirements, as those requirements differ.
The manufacturing plant location(s) identified on the certificate represent standard Hilti catalog products only. “Specially” produced
non-catalog Hilti products may have differing manufacturing plant locations.
Contact your Hilti representative in cases of “specially” produced products for a custom LEEDS certificates.
Hilti, Inc.
5400 South 122 n d East Avenue
Tulsa, OK 74146
1-800-879-8000
www.hilti.com
Product Information
Product features
• Pre-cut to industry standard size decking flutes
• Reduces material waste
• 3 sizes available
• Pre-cut — leaves no gaps or voids
• Smooth surface provides cost effective spray coverage
• Safer to use — no asbestos
• Up to 60% faster than castle cutting!
• CP 767: 4 PCF Density
• CP 777: 6 PCF Density
Areas of application
• Top-of-wall
Installation instructions
• See Hilti literature or third-party listings for complete application and installation
details
Flute Dimensions
Description Qty Item No.
(L x (Flute) x H)
Hilti Firestop
Saving lives
through innovation
and education
CERTIFICATE OF COMPLIANCE
Certificate Number 20160829-R13081
Report Reference R13081
Issue Date 2016-August-29
Standard(s) for Safety: ANSI/UL 2079, "Tests for Fire Resistance of Building Joint
Systems."
CAN/ULC-S115, "Standard Method of Fire Tests of Firestop
Systems."
Additional Information: See the UL Online Certifications Directory at
www.ul.com/database for additional information
Only those products bearing the UL Certification Mark should be considered as being covered by UL's
Certification and Follow-Up Service.
UL LLC
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
Page 1 of 1
Material Information Statement
Manufactured Articles
According to 1907/2006/EC, Article 32
Revision: 23.04.2019 Version: 14
Trade name:
Construction industry.
Refer to Hilti product literature, technical data sheets, 3rd party published listings and national approvals for specific application information. For
more details, please contact your local Hilti organization through http://www.hilti.group
Hilti AG
Feldkircherstr. 100
FL-9494 Schaan
Liechtenstein
Customer Service
Phone +423 (0)844 84 84 85
Fax +423 (0)844 84 84 86
2 Other information
A Safety Data Sheet is not required due to the classification of these products as “manufactured articles” according to Regulation (EC) No.
1907/2006 of 18 December 2006 (EU) / 29CFR 1910.1200 (U.S.A.). Consequently, these products are exempted from CLP / OSHA Labeling and
SDS requirements.
These data are based on our present knowledge. However, they shall not constitute a guarantee for any specific product features and shall not
establish a legally valid contractual relationship.
Informing department:
chemicals.hse@hilti.com
January 27, 2016
Re: Hilti CP767 Speed Strips and CP777 Speed Plugs – LEED Information
Item Numbers:
CP 767 CP 777
374505 340998
374506 340999
374507 371925
374508
The Hilti CP767 Speed Strips and CP777 Speed Plugs are manufactured in North Carolina.
Post-consumer recycled content of Hilti CP767 Speed Strips and CP777 Speed Plugs is 0%. Pre-consumer recycled content of
Hilti CP767 Speed Strips and CP777 Speed Plugs is 0%. There is no detectable VOC content either product.
Hilti CP767 Speed Strips and CP777 Speed Plugs are not regulated as a hazardous waste by the Federal EPA Standards. The
regulations for the disposal of non-regulated industrial waste can vary from state to state and even city to city. For this reason, you
should consult your local and state regulatory agencies for direction on disposal.
Sincerely,
The manufacturing plant location on this certificate has been provided for LEEDS reporting purposes only. It should never be used
for Country of Origin certification or a representation of compliance/non-compliance with Buy American or Buy America
requirements, as those requirements differ.
The manufacturing plant location(s) identified on the certificate represent standard Hilti catalog products only. “Specially” produced
non-catalog Hilti products may have differing manufacturing plant locations.
Contact your Hilti representative in cases of “specially” produced products for a custom LEEDS certificates.
Hilti, Inc.
5400 South 122 n d East Avenue
Tulsa, OK 74146
1-800-879-8000
www.hilti.com
Fire Containment Insulation Thermafiber® Safing™
+ F
ire resistant to temperatures above
2,000°F (1,093°C)
+ E
asy to fabricate for through
penetrations and firestopping
+ Resists moisture
70%
Quality
1 2.1, 2.2 9 1
Recycled 4.1, 4.2
Content1 5.1, 5.2
Thermafiber Safing and FireSpan® insulation provide the critical components of
the perimeter fire containment system in the 111 South Wacker Building in Chicago,
IL. Thermafiber insulation also contributed to the building’s LEED® Gold Rating.
All firestopping insulation should be installed per the architectural specification or system specific test description. All
Installation: compressed Safing insulation should be installed per the listed assembly.
• Perimeter Installation: SafingTM insulation should be compression fitted between the slab edge and the FireSpan
curtain wall insulation, leaving no voids.
• Penetration Application: Safing insulation should be cut slightly larger than the opening and compression fitted into the
opening, leaving no voids.
• Construction Joint Application: Safing insulation should be compression fitted into the joint opening, leaving no voids.
TF612/Rev 03-15 Copyright 2015, Thermafiber, Inc. All Rights Reserved. LEED® is a registered trademark of U.S. Green Building Council.
Safing 4.0 pcf 0.24 ‘R’= 4.2 0 0 25 0
Safing 6.0 pcf 0.24 ‘R’= 4.2 0 0 25 0
***R = thickness divided by ‘k’
SafingTM insulation is a critical component of any perimeter fire containment system. Thermafiber® has performed decades
Fire-Containment Tests of testing in all of the containment systems listed below. For more complete test information, see SA707, THERMAFIBER
Per ASTM E 2307 Life-Safety Fire Containment Systems technical catalog or UL® and Intertek® (formerly OPL) Directories. For a full listing of
containment systems visit www.thermafiber.com and click on Fire Rated Assemblies. UL Reference = TYPE SAF
• Aluminum Spandrel Curtain Wall Fire Containment
• Steel Stud-Framed/Gypsum Sheathing Curtain Wall Fire Containment
• Glass Spandrel Curtain Wall Fire Containment
• Granite Spandrel Curtain Wall Fire Containment
• Precast Concrete Spandrel
Thermafiber offers industry leading technical and engineering assistance to architects, specifiers, and contractors.
Thermafiber® Insolutions®: These services include CAD drawings, engineering judgments, LEED® Credit Information, product recommendations,
and customized products. Contact our technical services department at
1-888-834-2371, or email technicalservice@owenscorning.com
For additional information about these or other Thermafiber products contact us at 1-888-834-2371 or visit our
For Further Information: website www.thermafiber.com.
THERMAFIBER, Inc. shall not be liable for incidental and consequential damages, directly or indirectly sustained, nor for any loss caused by application of
Notice: these goods not in accordance with current printed instructions or for other than the intended use. THERMAFIBER liability is expressly limited to replacement of
defective goods. Any claim shall be deemed waived unless made in writing within thirty (30) days from date it was or reasonably should have been discovered.
Contractor Date
3711 Mill Street | Wabash, IN 46992 | 888-TFIBER1 [834-2371] | [260] 563-2111 | www.thermafiber.com
CERTIFICATE OF COMPLIANCE
Certificate Number 20151218-R10905
Report Reference R10905
Issue Date 2015-December-18
Only those products bearing the UL Certification Mark should be considered as being covered by UL's
Certification and Follow-Up Service.
UL LLC
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
Page 1 of 3
CERTIFICATE OF COMPLIANCE
Certificate Number 20151218-R10905
Report Reference R10905
Issue Date 2015-December-18
This is to certify that representative samples of the product as specified on this certificate were tested according to the
current UL requirements.
Type SAF mineral wool batts for use in Joint System Nos. BW-S-0029, FF-D-0002, FF-D-0011, FF-D-0013,
FF-D-0014, FF-D-0015, FF-D-0016, FF-D-0017, FF-D-0019, FF-D-0022, FF-D-0023, FF-D-0025, FF-D-0026,
FF-D-0028, FF-D-0073, FF-D-0074, FF-D-0096, FF-D-0097, FF-D-0109, FF-D-1001, FF-D-1002, FF-D-1003,
FF-D-1004, FF-D-1006, FF-D-1007, FF-D-1008, FF-D-1010, FF-D-1015, FF-D-1016, FF-D-1020, FF-D-1021,
FF-D-1024, FF-D-1025, FF-D-1027, FF-D-1036, FF-D-1039, FF-D-1040, FF-D-1041, FF-D-1042, FF-D-1045,
FF-D-1047, FF-D-1098, FF-D-1125, FF-D-1158, FF-D-3003, FF-D-3004, FF-S-1031, FF-S-1033, FW-D-0001,
FW-D-0004, FW-D-0007, FW-D-0009, FW-D-0010, FW-D-0011, FW-D-0012, FW-D-0014, FW-D-0017, FW-D-0018,
FW-D-0020, FW-D-0021, FW-D-0023, FW-D-0024, FW-D-0027, FW-D-0050, FW-D-0051, FW-D-0067, FW-D-0068,
FW-D-1001, FW-D-1002, FW-D-1003, FW-D-1005, FW-D-1006, FW-D-1007, FW-D-1009, FW-D-1010, FW-D-1016,
FW-D-1017, FW-D-1020, FW-D-1024, FW-D-1033, FW-D-1035, FW-D-1037, FW-D-1038, FW-D-1039, FW-D-1040,
FW-D-1044, FW-D-1047, FW-D-1055, FW-D-1070, FW-D-1089, FW-D-1092, FW-D-1093, FW-D-1102, FW-D-1103
FW-S-1016, FW-S-1019, HW-D-0001, HW-D-0002, HW-D-0006, HW-D-0009, HW-D-0013, HW-D-0016, HW-D-0017,
HW-D-0020, HW-D-0021, HW-D-0022, HW-D-0023, HW-D-0025, HW-D-0026, HW-D-0027, HW-D-0028, HW-D-0029,
HW-D-0030, HW-D-0031, HW-D-0034, HW-D-0038, HW-D-0039, HW-D-0040, HW-D-0042, HW-D-0043, HW-D-0044,
HW-D-0045, HW-D-0046, HW-D-0047, HW-D-0049, HW-D-0050, HW-D-0051, HW-D-0052, HW-D-0054,
HW-D-0055, HW-D-0058, HW-D-0059, HW-D-0062, HW-D-0064, HW-D-0067, HW-D-0069, HW-D-0072,
HW-D-0073, HW-D-0075, HW-D-0079, HW-D-0086, HW-D-0087, HW-D-0088, HW-D-0089, HW-D-0091,
HW-D-0092, HW-D-0099, HW-D-0100, HW-D-0101, HW-D-0102, HW-D-0103, HW-D-0104, HW-D-0105,
HW-D-0106, HW-D-0107, HW-D-0108, HW-D-0118, HW-D-0122, HW-D-0123, HW-D-0127, HW-D-0128,
HW-D-0131, HW-D-0136, HW-D-0137, HW-D-0139, HW-D-0140, HW-D-0143, HW-D-0146, HW-D-0149,
HW-D-0152, HW-D-0153, HW-D-0154, HW-D-0156, HW-D-0157, HW-D-0160, HW-D-0166, HW-D-0168,
HW-D-0170, HW-D-0171, HW-D-0172, HW-D-0173, HW-D-0174, HW-D-0177, HW-D-0178, HW-D-0185,
HW-D-0186, HW-D-0187, HW-D-0188, HW-D-0190, HW-D-0192, HW-D-0199, HW-D-0200, HW-D-0201,
HW-D-0204, HW-D-0205, HW-D-0206, HW-D-0208, HW-D-0211, HW-D-0218, HW-D-0220, HW-D-0221,
HW-D-0222, HW-D-0246, HW-D-0248, HW-D-0252, HW-D-0253, HW-D-0258, HW-D-0259, HW-D-0263,
HW-D-0265, HW-D-0278, HW-D-0279, HW-D-0297, HW-D-0298, HW-D-0299, HW-D-0335, HW-D-0336,
HW-D-0337, HW-D-0338, HW-D-0354, HW-D-0357, HW-D-0358, HW-D-0359, HW-D-0363, HW-D-0365,
HW-D-0366, HW-D-0367, HW-D-0377, HW-D-0378, HW-D-0380, HW-D-0381, HW-D-0384, HW-D-0385,
HW-D-0388, HW-D-0389, HW-D-0391, HW-D-0395, HW-D-0396, HW-D-0404, HW-D-0405, HW-D-0406,
HW-D-0407, HW-D-0408, HW-D-0409, HW-D-0410, HW-D-0411, HW-D-0412, HW-D-0413, HW-D-0414,
HW-D-0415, HW-D-0416, HW-D-0417, HW-D-0441, HW-D-0442, HW-D-0447, HW-D-0456, HW-D-0457,
HW-D-0460, HW-D-0465, HW-D-0467, HW-D-0468, HW-D-0478, HW-D-0479, HW-D-0524, HW-D-0531,
HW-D-0536, HW-D-0538, HW-D-0539, HW-D-0540, HW-D-0542, HW-D-0546, HW-D-0547, HW-D-0548,
HW-D-0549, HW-D-0553, HW-D-0560, HW-D-0561, HW-D-0562, HW-D-0564, HW-D-0566, HW-D-0567,
HW-D-0568, HW-D-0569, HW-D-0570, HW-D-0571, HW-D-0572, HW-D-0577, HW-D-0578, HW-D-0580,
UL LLC
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
Page 2 of 3
CERTIFICATE OF COMPLIANCE
Certificate Number 20151218-R10905
Report Reference R10905
Issue Date 2015-December-18
Type SAF mineral wool batts for use in Joint System Nos. HW-D-0582, HW-D-0583, HW-D-0584, HW-D-0590,
HW-D-0591, HW-D-0597, HW-D-0612, HW-D-0614, HW-D-0617, HW-D-0619, HW-D-0631, HW-D-0633,
HW-D-0634, HW-D-0635, HW-D-0636, HW-D-0639, HW-D-0640, HW-D-0642, HW-D-0643, HW-D-0644,
HW-D-0645, HW-D-0649, HW-D-0650, HW-D-0661, HW-D-0662, HW-D-0687, HW-D-0697, HW-D-0698,
HW-D-0702, HW-D-0703, HW-D-0704, HW-D-0725, HW-D-0726, HW-D-0735, HW-D-0740, HW-D-0741,
HW-D-0742, HW-D-0743, HW-D-0747, HW-D-0748, HW-D-0750, HW-D-1001, HW-D-1002, HW-D-1003,
HW-D-1004, HW-D-1005, HW-D-1006, HW-D-1007, HW-D-1010, HW-D-1013, HW-D-1014, HW-D-1015,
HW-D-1016, HW-D-1020, HW-D-1021, HW-D-1022, HW-D-1023, HW-D-1024, HW-D-1028, HW-D-1032,
HW-D-1033, HW-D-1034, HW-D-1037, HW-D-1040, HW-D-1042, HW-D-1044, HW-D-1045, HW-D-1050,
HW-D-1060, HW-D-1066, HW-D-1067, HW-D-1068, HW-D-1069, HW-D-1070, HW-D-1073, HW-D-1074,
HW-D-1075, HW-D-1076, HW-D-1077, HW-D-1079, HW-D-1080, HW-D-1089, HW-D-1094, HW-D-1097,
HW-D-1102, HW-D-1103, HW-D-1104, HW-D-1110, HW-S-0001, HW-S-0009, HW-S-0010, HW-S-0053,
HW-S-0054, HW-S-0080, HW-S-0083, HW-S-1015, WW-D-0013, WW-D-0018, WW-D-0019, WW-D-0020,
WW-D-0063, WW-D-1001, WW-D-1002, WW-D-0022, WW-D-0089, WW-D-0090, WW-D-0103, WW-D-0171,
WW-D-0140, WW-D-0141, WW-D-1003, WW-D-1004, WW-D-1005, WW-D-1006, WW-D-1007, WW-D-1010,
WW-D-1015, WW-D-1016, WW-D-1023, WW-D-1027, WW-D-1036, WW-D-1037, WW-D-1042, WW-D-1047,
WW-D-1089, WW-D-1090, WW-D-1091, WW-D-1128, WW-D-1129, WW-S-0064, WW-S-1035.
TYPE SAF MINERAL WOOL BATTS FOR USE IN PERIMETER FIRE CONTAINMENT SYSTEM N OS. CW-D-1001, CW-D-1002,
CW-D-1003, CW-D-1004, CW-D-1005, CW-D-1006, CW-D-1007, CW-D-1008, CW-D-1009, CW-D-1010,
CW-D-1011, CW-D-1012, CW-D-1013, CW-D-1014, CW-D-1015, CW-D-1016, CW-D-1017, CW-D-1018,
CW-D-1019, CW-D-1020, CW-D-1021, CW-D-1022, CW-D-1023, CW-D-1028, CW-D-1029, CW-D-1030,
CW-D-2001, CW-D-2002, CW-D-2003, CW-D-2005, CW-D-2006, CW-D-2008, CW-D-2009, CW-D-2010,
CW-D-2011, CW-D-2012, CW-D-2013, CW-D-2036, CW-D-2037, CW-D-2038, CW-D-2039, CW-D-2040,
CW-D-2041, CW-D-2042, CW-D-2046, CW-D-2047, CW-D-2048, CW-D-2049, CW-D-2050, CW-D-2051,
CW-D-2052, CW-D-2055, CW-D-2056, CW-D-2057, CW-D-2058, CW-D-2059, CW-D-2063, CW-D-2064,
CW-D-2065, CW-D-2066, CW-S-0001, CW-S-0002, CW-S-0003, CW-S-0004, CW-S-1001, CW-S-1002,
CW-S-1003, CW-S-1007, CW-S-1010, CW-S-1016, CW-S-1017, CW-S-1020, CW-S-1022, CW-S-1023,
CW-S-1024, CW-S-1025, CW-S-1026, CW-S-2001, CW-S-2002, CW-S-2003, CW-S-2006, CW-S-2008,
CW-S-2014, CW-S-2021, CW-S-2022, CW-S-2023, CW-S-2025, CW-S-2029, CW-S-2034, CW-S-2035,
CW-S-2036, CW-S-2058, CW-S-2059, CW-S-2060, CW-S-2061, CW-S-2062, CW-S-2064, CW-S-2065,
CW-S-2066.
TYPE SAF MINERAL WOOL BATTS FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEM NOS . C-AJ-1020, C-AJ-1081,
C-AJ-3045, W-L-1027, W-L-1039, W-L-1064, W-L-1065, W-L-2023, W-L-2036, W-L-3023, W-L-3034, W-L-7001,
W-L-7002.
TOPSTOP MINERAL WOOL DECK PLUGS TYPE SAF BATTS FOR USE IN JOINT SYSTEM NOS. HW-D-0001, HW-D-0002,
HW-D-0020, HW-D-0022, HW-D-0034, HW-D-0039, HW-D-0043, HW-D-0086, HW-D-0088, HW-D-0160,
HW-D-0161, HW-D-0456, HW-D-0612, HW-D-0644.
UL LLC
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
Page 3 of 3
Material Information Statement
Manufactured Articles
According to 1907/2006/EC, Article 32
Revision: 23.04.2019 Version: 14
Trade name:
Construction industry.
Refer to Hilti product literature, technical data sheets, 3rd party published listings and national approvals for specific application information. For
more details, please contact your local Hilti organization through http://www.hilti.group
Hilti AG
Feldkircherstr. 100
FL-9494 Schaan
Liechtenstein
Customer Service
Phone +423 (0)844 84 84 85
Fax +423 (0)844 84 84 86
2 Other information
A Safety Data Sheet is not required due to the classification of these products as “manufactured articles” according to Regulation (EC) No.
1907/2006 of 18 December 2006 (EU) / 29CFR 1910.1200 (U.S.A.). Consequently, these products are exempted from CLP / OSHA Labeling and
SDS requirements.
These data are based on our present knowledge. However, they shall not constitute a guarantee for any specific product features and shall not
establish a legally valid contractual relationship.
Informing department:
chemicals.hse@hilti.com
September 24, 2015
Item Number:
236993
The post-consumer recycled content in the Hilti Mineral Wool is 0%. The pre-consumer recycled content in the Hilti Mineral Wool
is 90%. There is no detectable VOC content in this product.
Hilti Mineral Wool is not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the disposal of non-
regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult your local and
state regulatory agencies for direction on disposal.
Sincerely,
The manufacturing plant location on this certificate has been provided for LEEDS reporting purposes only. It should never be used
for Country of Origin certification or a representation of compliance/non-compliance with Buy American or Buy America
requirements, as those requirements differ.
The manufacturing plant location(s) identified on the certificate represent standard Hilti catalog products only. “Specially” produced
non-catalog Hilti products may have differing manufacturing plant locations.
Contact your Hilti representative in cases of “specially” produced products for a custom LEEDS certificates.
Hilti, Inc.
5400 South 122 n d East Avenue
Tulsa, OK 74146
1-800-879-8000
www.hilti.com