Ventilator System
Nihon Kohden ventilators represent the future of patient care
Improving patient safety, quality of care and outcomes,
while also managing costs are critical goals in today's
acute care environment. Medical devices making a positive
contribution towards these goals will be crucial to the
health care of the future.
—What attributes should a NPPV
ventilator of the future have?—
Solutions for better outcomes
Reliable ventilation preventing life-threatening events
Improving Patient Care
Critical information, intuitive interface, increased patient comfort
Flexibility
From ER to Recovery, Invasive to O2 therapy
Manage Patient Safety
Easily viewable alarms, "hot-swap" battery, HEPA filter
The Nihon Kohden NKV-330 does all this and more, and is
your solution for mechanical ventilation management.
Solution for a better outcomes
Safe, reliable respiratory management
Multiple ventilation modes to address a
variety of clinical environments
Availability of multiple non-invasive ventilation modes as well as a high flow
oxygen therapy mode allows the NKV-330 to operate in various clinical settings
including the ER, intensive care, and intra-hospital transport.
de
n mo
ti o
e n t il a SPONT-PS
V
spontaneous ventilation with pressure support
S/T
spontaneous with timed backup
PCV
pressure control ventilation
PRVC
An pressure regulated volume control
ox
yg
en
the
ra p
ym
od
e
O 2 Therapy
high flow oxygen therapy
Smart Cable system – unique modular connection technology
Using a Smart Cable connecting to a MULTI socket, the NKV-330 automatically detects the parameter (CO2/
SpO2) and starts measuring, which is reflected in the layout of display items on the screen. Realtime monitoring
helps to prevent life-threatening events.
Connecting Recognize
CO2
SpO2
Continuous CO2 and SpO2 monitoring
CO2 and SpO2 monitoring are available, even when the ventilator is in Standby mode.
Nihon Kohden's unique technologies contribute to increasing patient safety
Reliable even under high humidity conditions.
Safe heaterless system prevents burn injuries.
Reliable SpO2 probes from the company that
invented SpO2.
Improving patient Quality of Life
Efficient, quality care
Critical information at your fingertips
The NKV-330 can store up to 72 hours of full-disclosure waveforms, alarm and operation logs, and patient
measurements, allowing the physician to review critical clinical data to determine the best treatment protocol.
Intuitive interface gives you more time for your patients
The sleek, attractive design includes a 12.1 inch color touch screen and operation knob that facilitates
respiratory setting changes while still displaying current waveforms.
KNV330VentilatorCatalog_En_190227.indd 7 2019/10/10 13:46
Increase patient comfort
Formfitting NPPV mask
The Nihon Kohden NPPV mask is designed to fit any facial shape with minimal patient discomfort and skin damage.
Adjust the attachment position using
the support arm of the mask cushion
to fit the mask to patient’s face.
Support arm
Continuous CO2 monitoring during NPPV therapy
The combination of cap-ONE, Nihon Kohden's new class of ultra-compact CO2
sensor, and dedicated NPPV mask optimizes the ability to monitor and detect
changes in the patient's condition, improving patient care and outcomes. This is
particularly useful for measuring carbon dioxide (CO2) during NPPV therapy.
Oxygen flow
from ventilator
CO 2 flow
A flexible ventilator for the dynamic
Mechanical ventilation for the
entire spectrum of respiratory care
Transport
ER
One action to detach the
NKV-330 from the cart.
hospital environment
Recovery
Rehab
ICU
Flexibility to cope with changing patient conditions
Managing Patient Safety
System alerts and redundancy
ensure patient safety
Easily viewable ventilator alarms Ensure continuous operations
A clearly visible alarm indicator on the top of the 12.1 Equipped with both a "hot swap" main battery and an
inch display combined with audible alerts provides internal backup battery, caregivers can be confident
caregivers prompt notification of critical ventilator that should a loss of AC power occur, the NKV-330's
events. operation will continue uninterrupted.
Red
Dual filter protection
Yellow
The NKV-330 incorporates dual HEPA filtration. Air
going to the internal blower first passes through a dust
filter, then through a HEPA filter, prior to reaching the
blower. Air going to the patient passes through an
Cyan additional HEPA filter which is located internal to the
Gas Outlet Connection.
HEPA filter
Prevent missing alarms Dust filter
Breathing
A dual speaker system ensures that an alarm condition circuit filter
will result in an audible alert to the caregiver, even if one
speaker fails.
nOptions
Mount plate DH-330Z Rail hook DH-331Z
Cart, M (H 1000 mm) KC-330Z
Cart, L (H 1100 mm) KC-331Z
Mask for NPPV
NPPV mask NPPV mask with CO2 measurement
NPPV full face mask set cap-ONE mask set
NPPV full face mask set L VM-310Z NPPV cap-ONE mask set L VM-330Z
NPPV full face mask set M VM-311Z NPPV cap-ONE mask set M VM-331Z
NPPV full face mask set S VM-312Z NPPV cap-ONE mask set S VM-332Z
Full face mask cushion L VA-310Z cap-ONE mask cushion L VM-330Z
Disposable Full face mask cushion M VA-311Z cap-ONE mask cushion M VM-331Z
Full face mask cushion S VA-312Z cap-ONE mask cushion S VM-332Z
NPPV mask flame VA-380Z
Reusable
NPPV head gear VA-381Z
This brochure may be revised or replaced by Nihon Kohden at any time without notice.
9842 CAT.No.68-0006A ’19.10. SZ. PDF.