0% found this document useful (0 votes)
106 views8 pages

Industrial Warning Light Guide

This document provides instructions for a bulb revolving warning light and electric horn combination made by Qlight for vessel and industrial applications. It includes safety precautions for installation, use, and maintenance. The ordering specifications list the available models, voltages, colors, and sound patterns. Product specifications provide details on bulb type, voltage, current, sound volume and patterns, certifications, dimensions, and how to select different sound settings using the internal switch.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
106 views8 pages

Industrial Warning Light Guide

This document provides instructions for a bulb revolving warning light and electric horn combination made by Qlight for vessel and industrial applications. It includes safety precautions for installation, use, and maintenance. The ordering specifications list the available models, voltages, colors, and sound patterns. Product specifications provide details on bulb type, voltage, current, sound volume and patterns, certifications, dimensions, and how to select different sound settings using the internal switch.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Bulb Revolving Warning Light and Electric Horn Combination

for Vessels and Heavy Industry Applications

SCDW/ SCDF
20 50
118
66 HORN

Thank you for purchasing Qlight’s products. Please read this user manual carefully
prior to installation and operation to ensure safe and correct use.

Precautions for Safety


Failure to follow the instructions below may cause a loss of life or serious physical injury.
1. During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
ratings indicated for each product. (Failure to follow these instructions may cause a fire to the product, electric shock, physical injury,
malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to
follow these instructions may lead to fire, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to fire, electric shock, or product damage.)
5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to
follow this may cause damage to property, fire, electric shock and loss of life.)

Precautions for Correct Use


Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the product
that would void the warranty.
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn off the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product’s specification.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, fire, and electric shock.

Ordering Specifications

SCDW - WA - 24 - R
[Model
[Sound] [Voltage] [Color]
number]
| | | |

• SCDW • WS-Warning sounds • 12 - DC12V R-Red


• SCDF • WP-special warning sounds • 24 - DC24V A-Amber
• WM-Melodies • 110 - AC110V G-Green
• WA-Alarms • 220 - AC220V B-Blue
• WV-Customizable sounds

Please scan the QR code for more


detailed product information.
www.qlight.com

1
Product Specifications

Model Bulb specifications


Voltage Current Sound pattern and volume Certificate Weight Color
number Volts/Watts Configuration Part#
DC12V 3.755A 12V15W 17
• WS-5 Warning Sounds : 118dB 2.68kg R-Red
DC24V 1.788A 24V15W 18 • WP-5 special warning sounds : 118dB
SCDW A-Amber
G23 15S • WM-5 Melodies : 118dB
SCDF AC110V 0.422A 12V15W 17 • WA- 5 Alarms : 116dB G-Green
• WV-5 Customizable sounds : 113dB 3.60kg B-Blue
AC220V 0.211A 12V15W 17

※ CE compliant : DC24V
• Protection rating : IP66
• Ambient operating temperature : -20°C to +50°C

Dimensions (Units : mm)


SCDWLR/ SCDWL/ SCDWS/ SCDW SCDFLR/ SCDFL/ SCDFS/ SCDF
SCDW SCDF
Ø140 Ø140
313

322
150

10
4-Ø9
FITTING HOLES 146 10 146 167
170 177
249 4-Ø9
249 170 FITTING HOLES

119
9

Sound Setting - Select using the switch inside of the unit.


■ Sound Type by Group
Sound pat- volume
Category Channel Sound Tone
tern (Max.)
Ch1 Fire.A-ANG
Ch2 Emergency WA-U
WS 5 Warning
Ch3 Ambulance PI-PO 118dB
sounds
Ch4 Machinery Fault
Ch5 High Expansion
Ch1-Ch5 sound setting switch Ch1 Fire.A-ANG
5 Special Ch2 Abandon Alarm
• Standard unit has 5 built-in sound tones.
WP Warning Ch3 Machinery Fault 118dB
Select different built-in sounds using the sound setting switch.
sounds Ch4 High Expansion
• For standard type, once the unit is powered on, light and sound
are working simultaneously. Ch5 7 Short PI. / 1 Long
Ch1 Sweet Home
■Volume Adjustment Ch2 For Elise
WM 5 Melodies Ch3 Cuckoo's Waltz 118dB
Volume Dial • The volume output of this product Ch4 Piano Sonata
is adjustable.
MAX. MIN. Ch5 Turkish March
• Turn the volume dial clockwise to
increase the volume, and Ch1 Beep Intermittent
turn counter clockwise to decrease Ch2 Door Chime
the volume. WA 5 Alarms Ch3 Phone Ring 116dB
• There will be no sound when the Ch4 PI.PI.PI Short
dial is put at MIN.
VOL.
Ch5 Tripping Beat
5 Customiz- Ch1- Available upon request
WV 113dB
able sounds Ch5 (customized voice type)

2
Wiring Instructions for LC Type

• LC type product with exposed sound selection signal line is avali-


able upon request. Please refer to the diagram below for wiring.

(EXTERNAL CONTACT) (EXTERNAL TRASISTOR-NPN)

Red Red
Ch1
Amber Amber Ch1
Ch2
Green Green Ch2
Ch3
Blue Blue Ch3
Ch4
White White Ch4
Ch5
Ch5
Black Common Black Common

White White
Black Fuse Power Black Fuse Power

• External power line - UL1015 AWG18(0.75sq) x 2C 400mm


• External signal line - UL1007 AWG22(0.3sq) 400mm

Terminal Box Wiring Instructions

• Terminal block is located inside of the product. Unscrew the 4 bolts located in the upper body
to get rid of the upper lighting element of the unit.
① • Please apply fork (U-type) or ring (O-type) locking spade terminal at naked tip of the wire for
secure connection.
• Please wire the power line to terminal ①
• For AC type products, wire regardless of polarity.
• For DC type products, wire terminal of black line to (-) polarity.

Parts Definition/ Installation

Protection cage
(STS316L)
Lens(PC)

Horn(PC)
Terminal
block
Housing(PC+GF)

• First, machine holes on the mounting surface.


• The mounting hole of this product is 9mm in diameter.
• When machining taps, fasten the bolt through the mounting hole of the bracket.
• When machining holes, insert the bolt through the hole of the product, and tighten the nut from the opposite side of the mounting surface.
• When assembling using bolt and nut, please make sure to use flat washer and spring washer.

3
Mounting Hole Specifications/Light bulb Replacement lnstructions

■Mounting Hole Specifications


• Machine holes on the mounting surface referring to the diagram below. 15
0

4-Ø9 HOLES

4-Ø9 HOLES
170

170
119

SCDF SCDW

■Light bulb Replacement Instructions

• Please wait at least 1 minute after turning off the power


① before replacing the bulb.
• In order to dissemble the bulb, please push down the bulb(①)
Assemble bulb
② lightly and screw it counterclockwise.
• In order to put the bulb in to the unit, please place the bulb(①)
Disassemble bulb
in the socket(②) and screw it clockwise while lightly pushing
down the bulb.

Installation Environment and Protection Rating


• This product is designed for use with protection rating of IP66.
• If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating
indicated(IP66), it may cause malfunction or damage to the product.
• In case of outdoor applications, install the product in the upright position. Do not install the product horizontal or upside-
down positions where water can potentially penetrate into the product and impact it’s operation.
• For further information, please visit our website (www.qlight.com).

4
Technical Certification

• Qlight products are designed to meet strict quality and technical standards. Thus, the Qlight brand is widely recognized for its high quality
and technical innovations from leading institutions around the world.

ISO International Organization for IECEx International Explosion


Standardization
Qlight quality assurance systems have been
manufactured and manage according to
KS Q ISO 9001:2009 regulation. international standards.

ATEX The European Regulatory NEPSI National Supervision and Inspection


Framework or Manufacture, Center for Explosion Protection
Installation and Use of Equip- and Safety of Instrumentation
ment in Explosive Atmospheres Qlight’s design and manufacturing system
meets the People’s Republic of China National
Qlight’s explosion proof products comply with ATEX explosion proof Standard.
Directives 94/9/EC. (Chinese Standard-GB3836/GB12476)

KCs Explosion Proof Device TIIS Japan Explosion-proof


Safety Certification System
TIIS is a Japanes explosion proof test and certification
The safety performance of machines and system accordance with the Ministry of Health, Labour
and Welfare Notice and the explosion proof guidelines for
Technical capability and production system have factory electrical equipment. Qlight's explosion proof
standards. products hasve been tested and certified by TIIS.

RMRS Russian Maritime


ABS American Bureau of Shipping Register of Shipping
Qlight’s design and quality assurance system Qlight’s design and quality assurance system has

Shipping. Shipping.

CCS KR Korean Register of Shipping


Qlight’s design and quality assurance system has Qlight’s design and quality assurance system has

E-mark Commission Directive


LR Lloyd’s Register Regarding Vehicle Industry
Qlight’s design and quality assurance system has Qlight has obtained EU mark for approved vehicles and
vehicle components sold into the EU(EEA : European
Economic Area)

KCC Conformity Assessment of Broad-


KC casting Communication Equipment
Qlight has been certified to protect the electromagnetic
Qlight’s products are certified by KC for preventing environment that causes unwanted electromagnetic
accident caused by fire. waves from the device, communication failure due to
other devices or external radio waves, and malfunction
of the device.

CCCF
CCC Security & Protection
Qlight has passed the rigorous examination process
Qlight’s has obtained CCC which guarantees safety,
of "Passing Fire Protection Products Centering" In order
protection against fraud, environment, etc.
to sell fire-fighting products such as fire alarm equipment
to Chinese market.

UL Underwriters Laboratories CE European Commission


Qlight’s design and quality assurance system has
been certified from UL to ensure the stability
Commission.
of consumption goods and to protect consumers.

ICAO International Civil Aviation RoHS2 Restriction of Hazardous


Organization Substances Directive
Qlight guarantees our products satisfy the criteria Qlight c omplies with the Restriction of Hazardous
regulated by the International Civil Aviation Substances Directive by limiting its use of hazardous
Organization(ICAO, FAA). materials.
MEMO
MEMO
Specification and dimensions listed in this catalogue subject to change without notice for product quality improvement.
For your safety The newest product information is available on our website.(www.qlight.com)
Please read the instruction manual attached to the product carefully before installation and use.

Qlight Co., Ltd. www.qlight.com | trade@qlight.com


Head Office | Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea
Tel. +82-2-2679-6152(Toll free. +82-80-328-2222) Fax. +82-2-2679-6154
Factory | 185-25, Mukbang-ro, Sangdong-myeon, Gimhae-si, Gyeongsangnamdo, Korea Tel. +82-55-328-1111(Toll free. +82-80-328-1111)
Qlight Overseas Sales Dept | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel : +82-51-620-4100
Qlight Public Relations & Marketing Team Office | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel. +82-51-245-0017

Qlight USA, Inc. www.qlight.com www.qlightusa.com | sales@qlightusa.com


3003 North First Street, Suite #341, San Jose, CA 95134 USA Tel. +1 - 408 - 519 - 5740 Fax. +1 - 408 - 519 - 5739

SHANGHAI Qlight Electronic Co., Ltd. www.qlight.com www.qlightcn.com | qlightcn@qlight.com


China Factory/ Shanghai Sales Office | #19, Nanda Road, Baoshan Area, Shanghai, China Tel. +86 - 21 - 6651 - 7100 Fax. +86 - 21 - 6315 - 3929

Product Operation Inquiry / Customer Support +82-51-620-4100


You can expect prompt service if you have exact information such as model name, symptom, telephone number and address.
※ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Head office : Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea (Postal Code : 08507)
Factory : 185-25, Mukbang-Ro, Sangdong-Myeon, Gimhae-Si, Gyeongsangnam-Do, Korea (Postal Code : 50805)
www.qlight.com

EN - SCDW -2011A