0% found this document useful (0 votes)
197 views25 pages

Laboratory C.B.R. Test Data Sheet (As Per IS:2720 Part 16) Location

This document contains the results of CBR (California Bearing Ratio) tests conducted on soil samples from 3 locations along the Odlabari to Kranti Bazar Road to determine the strength of the soil. The CBR values ranged from 4.9% to 6.5% indicating that the soil has low to moderate strength. Load versus penetration graphs are also provided for each test location.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
197 views25 pages

Laboratory C.B.R. Test Data Sheet (As Per IS:2720 Part 16) Location

This document contains the results of CBR (California Bearing Ratio) tests conducted on soil samples from 3 locations along the Odlabari to Kranti Bazar Road to determine the strength of the soil. The CBR values ranged from 4.9% to 6.5% indicating that the soil has low to moderate strength. Load versus penetration graphs are also provided for each test location.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 25

Road Name : Odlabari to Kranti Bazar Road

Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 0.15 Km (Left Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 17 20.4
1 38 45.6
1.5 55 65.9
2 65 77.9
2.5 72 86.3 89.5 1370 6.53
3 86 103.1 6.5%
4 99 118.7
5 107 128.3 129.1 2055 6.28
7.5 124 148.7
10 134 160.7
12.5 141 169.1

Probing Ring Least count : 1.199 Kg

180
170
160
LOAD (KG) >>

150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 1.15 Km (Right Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 15 18.0
1 34 40.8
1.5 49 58.8
2 59 70.7
2.5 65 77.9 81.2 1370 5.93
3 78 93.5 5.9%
4 89 106.7
5 97 116.3 117.1 2055 5.70
7.5 112 134.3
10 122 146.3
12.5 127 152.3

Probing Ring Least count : 1.199 Kg

160
150
140
LOAD (KG) >>

130
120
110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 2 Km (Left Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 19 22.8
1 35 42.0
1.5 50 60.0
2 60 71.9
2.5 67 80.3 80.3 1370 5.86
3 79 94.7 5.9%
4 88 105.5
5 98 117.5 117.5 2055 5.72
7.5 113 135.5
10 121 145.1
12.5 127 152.3

Probing Ring Least count : 1.199 Kg

160
150
140
LOAD (KG) >>

130
120
110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 3 Km (Right Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 13 15.6
1 26 31.2
1.5 39 46.8
2 47 56.4
2.5 56 67.1 67.1 1370 4.90
3 67 80.3 4.9%
4 77 92.3
5 83 99.5 99.5 2055 4.84
7.5 96 115.1
10 104 124.7
12.5 109 130.7

Probing Ring Least count : 1.199 Kg

140
130
120
LOAD (KG) >>

110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 4 Km (Left Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 16 19.2
1 35 42.0
1.5 51 61.1
2 60 71.9
2.5 67 80.3 82.8 1370 6.04
3 80 95.9 6.0%
4 92 110.3
5 99 118.7 119.3 2055 5.81
7.5 115 137.9
10 125 149.9
12.5 131 157.1

Probing Ring Least count : 1.199 Kg

170
160
150
LOAD (KG) >>

140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 5 Km (Left Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 18 21.6
1 32 38.4
1.5 47 56.4
2 56 67.1
2.5 64 76.7 76.7 1370 5.60
3 74 88.7 5.6%
4 85 101.9
5 92 110.3 110.3 2055 5.37
7.5 106 127.1
10 115 137.9
12.5 122 146.3

Probing Ring Least count : 1.199 Kg

160
150
140
LOAD (KG) >>

130
120
110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 6.5 Km (Right Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 12 14.4
1 28 33.6
1.5 40 48.0
2 47 56.4
2.5 52 62.3 65.6 1370 4.79
3 63 75.5 4.8%
4 72 86.3
5 78 93.5 94.2 2055 4.59
7.5 90 107.9
10 98 117.5
12.5 103 123.5

Probing Ring Least count : 1.199 Kg

130
120
LOAD (KG) >>

110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 8 Km (Left Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 21 25.2
1 37 44.4
1.5 53 63.5
2 64 76.7
2.5 73 87.5 87.5 1370 6.39
3 84 100.7 6.4%
4 94 112.7
5 105 125.9 125.9 2055 6.13
7.5 123 147.5
10 129 154.7
12.5 135 161.9

Probing Ring Least count : 1.199 Kg

170
160
150
LOAD (KG) >>

140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 9 Km (Right Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 16 19.2
1 35 42.0
1.5 51 61.1
2 60 71.9
2.5 67 80.3 82.8 1370 6.04
3 80 95.9 6.0%
4 92 110.3
5 99 118.7 119.3 2055 5.81
7.5 115 137.9
10 125 149.9
12.5 131 157.1

Probing Ring Least count : 1.199 Kg

170
160
150
LOAD (KG) >>

140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 10 Km (Left Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 21 25.2
1 37 44.4
1.5 54 64.7
2 64 76.7
2.5 74 88.7 88.7 1370 6.48
3 85 101.9 6.5%
4 96 115.1
5 106 127.1 127.1 2055 6.18
7.5 125 149.9
10 131 157.1
12.5 137 164.3

Probing Ring Least count : 1.199 Kg

180
170
160
LOAD (KG) >>

150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 11 Km (Right Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 17 20.4
1 34 40.8
1.5 50 60.0
2 61 73.1
2.5 72 86.3 86.3 1370 6.30
3 86 103.1 6.3%
4 99 118.7
5 107 128.3 128.3 2055 6.24
7.5 124 148.7
10 134 160.7
12.5 141 169.1

Probing Ring Least count : 1.199 Kg

180
170
160
LOAD (KG) >>

150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 12 Km (Left Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 20 24.0
1 34 40.8
1.5 49 58.8
2 58 69.5
2.5 64 76.7 76.7 1370 5.60
3 74 88.7 5.6%
4 85 101.9
5 92 110.3 110.3 2055 5.37
7.5 106 127.1
10 115 137.9
12.5 122 146.3

Probing Ring Least count : 1.199 Kg

160
150
140
LOAD (KG) >>

130
120
110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 13 Km (Right Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 18 21.6
1 30 36.0
1.5 44 52.8
2 54 64.7
2.5 61 73.1 73.1 1370 5.34
3 72 86.3 5.3%
4 81 97.1
5 89 106.7 106.7 2055 5.19
7.5 103 123.5
10 110 131.9
12.5 116 139.1

Probing Ring Least count : 1.199 Kg

150
140
130
LOAD (KG) >>

120
110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 14 Km (Left Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 16 19.2
1 35 42.0
1.5 51 61.1
2 60 71.9
2.5 67 80.3 82.8 1370 6.04
3 80 95.9 6.0%
4 92 110.3
5 99 118.7 119.3 2055 5.81
7.5 115 137.9
10 125 149.9
12.5 131 157.1

Probing Ring Least count : 1.199 Kg

170
160
150
LOAD (KG) >>

140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 15 Km (Right Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 15 18.0
1 34 40.8
1.5 49 58.8
2 58 69.5
2.5 64 76.7 80.0 1370 5.84
3 77 92.3 5.8%
4 88 105.5
5 96 115.1 115.9 2055 5.64
7.5 111 133.1
10 120 143.9
12.5 126 151.1

Probing Ring Least count : 1.199 Kg

160
150
140
LOAD (KG) >>

130
120
110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 16 Km (Left Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 18 21.6
1 33 39.6
1.5 47 56.4
2 56 67.1
2.5 63 75.5 75.5 1370 5.51
3 74 88.7 5.5%
4 83 99.5
5 92 110.3 110.3 2055 5.37
7.5 107 128.3
10 114 136.7
12.5 119 142.7

Probing Ring Least count : 1.199 Kg

150
140
130
LOAD (KG) >>

120
110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 17 Km (Right Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 15 18.0
1 34 40.8
1.5 49 58.8
2 59 70.7
2.5 65 77.9 81.0 1370 5.91
3 77 92.3 5.9%
4 89 106.7
5 96 115.1 115.9 2055 5.64
7.5 112 134.3
10 121 145.1
12.5 127 152.3

Probing Ring Least count : 1.199 Kg

160
150
140
LOAD (KG) >>

130
120
110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 18 Km (Left Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 15 18.0
1 34 40.8
1.5 50 60.0
2 59 70.7
2.5 65 77.9 81.2 1370 5.93
3 78 93.5 5.9%
4 90 107.9
5 97 116.3 117.1 2055 5.70
7.5 113 135.5
10 122 146.3
12.5 128 153.5

Probing Ring Least count : 1.199 Kg

170
160
150
LOAD (KG) >>

140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 19 Km (Right Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 18 21.6
1 30 36.0
1.5 44 52.8
2 54 64.7
2.5 61 73.1 73.1 1370 5.34
3 72 86.3 5.3%
4 81 97.1
5 89 106.7 106.7 2055 5.19
7.5 103 123.5
10 110 131.9
12.5 116 139.1

Probing Ring Least count : 1.199 Kg

150
140
130
LOAD (KG) >>

120
110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 20.2 Km (Left Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 14 16.8
1 31 37.2
1.5 44 52.8
2 53 63.5
2.5 58 69.5 72.1 1370 5.26
3 70 83.9 5.3%
4 80 95.9
5 87 104.3 104.9 2055 5.10
7.5 100 119.9
10 109 130.7
12.5 114 136.7

Probing Ring Least count : 1.199 Kg

150
140
130
LOAD (KG) >>

120
110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 21 Km (Right Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 19 22.8
1 32 38.4
1.5 46 55.2
2 54 64.7
2.5 61 73.1 73.1 1370 5.34
3 70 83.9 5.3%
4 80 95.9
5 87 104.3 104.3 2055 5.08
7.5 100 119.9
10 109 130.7
12.5 116 139.1

Probing Ring Least count : 1.199 Kg

150
140
130
LOAD (KG) >>

120
110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 22 Km (Left Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 15 18.0
1 34 40.8
1.5 49 58.8
2 58 69.5
2.5 64 76.7 80.0 1370 5.84
3 77 92.3 5.8%
4 88 105.5
5 96 115.1 115.9 2055 5.64
7.5 111 133.1
10 120 143.9
12.5 126 151.1

Probing Ring Least count : 1.199 Kg

160
150
140
LOAD (KG) >>

130
120
110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 23 Km (Right Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 17 20.4
1 30 36.0
1.5 43 51.6
2 51 61.1
2.5 59 70.7 70.7 1370 5.16
3 68 81.5 5.2%
4 76 91.1
5 84 100.7 100.7 2055 4.90
7.5 99 118.7
10 104 124.7
12.5 109 130.7

Probing Ring Least count : 1.199 Kg

140
130
120
LOAD (KG) >>

110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 24 Km (Left Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 16 19.2
1 35 42.0
1.5 51 61.1
2 60 71.9
2.5 67 80.3 82.8 1370 6.04
3 80 95.9 6.0%
4 92 110.3
5 99 118.7 119.3 2055 5.81
7.5 115 137.9
10 125 149.9
12.5 131 157.1

Probing Ring Least count : 1.199 Kg

170
160
150
LOAD (KG) >>

140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>
Road Name : Odlabari to Kranti Bazar Road
Laboratory C.B.R. Test Data Sheet (As per IS:2720 Part 16)

Test condition : Soaked Location


Nature of sample : Compacted in 5 layers with 55
blows of 4.9 kg rammer having 45 25 Km (Right Side)
cm drop at OMC (approx.)

Load & Penetration Data


Test Load (kg)
Penetration Corrected Standard % Standard
Dial Guage C.B.R.
(mm) Load Load (kg) Load (kg) load (%)
Reading
0.5 16 19.2
1 28 33.6
1.5 40 48.0
2 48 57.6
2.5 55 65.9 65.9 1370 4.81
3 64 76.7 4.8%
4 73 87.5
5 79 94.7 94.7 2055 4.61
7.5 91 109.1
10 99 118.7
12.5 105 125.9

Probing Ring Least count : 1.199 Kg

140
130
120
LOAD (KG) >>

110
100
90
80
70
60
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PENETRATION (mm) >>