Bulletin No.
: ISB-2001004
Date : July 25,2001
Component
: 09 - Body and accessories
catagory
Bulletin Group : Technical
Distribution : World wide
Subject : Memory input to REKES
Models : Musso and Korando with the REKES
Condition :
This service bulletin is issused to clarify the procedure of REKES memory input on workshop manual.
REKES memory is inputed when,
● The REKES transmitter is lost or faulty
● The REKES receiver is faulty
Work procedure :
1. 1st method : input memory using the switch of the REKES receiver
1-1. Location of the REKES receiver
1-1-1. Musso (before 1998 ; V.I.N. ~ 140079)
: under the dashboard and heater unit (rear side of audio head unit)
REKES receiver
: Musso (after 1998)
and Korando
REKES receiver
on the bracket
: Musso (before 1998)
This service bulletin is intended for internal use only. All information, illustrations and specifications contained in this bulletin are
based on the latest product information available at the time of issue.
International A/S & parts team
Tel: 82-31-610-1400
Fax: 82-31-610-3373
Printed in Korea ISB-2001004
E-mail:sykim1@smotor.com SSANGYONG MOTORS COMPANY Page No: 1 of 6
1-1-2. Musso (after 1998 ; V.I.N. 140080~)
: under the dashboard and upper the acceleration pedal with STICS unit
Air duct
REKES
receiver
Vacuum lines
of the ignition
key switch
(diesel only)
Crank assy
-bell,
Acceleration
STICS unit
1-1-3. Korando : under the dashboard and upper the acceleration pedal
Heater
Air duct
unit
Acceleration
cable
REKES
receiver
Crank assy
-bell,
Acceleration
This service bulletin is intended for internal use only. All information, illustrations and specifications contained in this bulletin are
based on the latest product information available at the time of issue.
International A/S & parts team
1-2. Location of the input memory switch (Musso and Korando all)
Tel: 82-31-610-1400
Fax: 82-31-610-3373
Printed in Korea ISB-2001004
E-mail:sykim1@smotor.com SSANGYONG MOTORS COMPANY Page No: 2 of 6
REKES receiver
Input memory switch
1-3. Formation of the input memory switch (Musso and Korando all)
1-3-1. Old version receiver (~ Apr.19,1997)
Operating
position
1 2
1st transmitter 2nd transmitter
input input
position position
1-3-2. New version receiver (Apr.20,1997 ~)
Operating
position
Transmitter
(only one)
input
position
This service bulletin is intended for internal use only. All information, illustrations and specifications contained in this bulletin are
based on the latest product information available at the time of issue.
International A/S & parts team
1-4. Input memory procedure : in condition of taking the key out
Tel: 82-31-610-1400
Fax: 82-31-610-3373
Printed in Korea ISB-2001004
E-mail:sykim1@smotor.com SSANGYONG MOTORS COMPANY Page No: 3 of 6
1-4-1. Old version receiver (~ Apr.19,1997)
① Replace the REKES receiver with a new one and connect the wiring connector when
the REKES receiver is faulty only.
② Set the input memory switch of the REKES receiver onto the no.1 or no.2 position and
push the lock or unlock button on the REKES transmitter.
③ Set the input memory switch of the REKES receiver onto the central position and
close all doors.
④ Check the operation of central door lock system by pushing the lock and unlock button
on the REKES transmitter.
⑤ This REKES version can use two transmitters simultaneously for a vehicle.
1-4-2. New version receiver (Apr.20,1997 ~)
① Replace the REKES receiver with a new one and connect the wiring connector when
the REKES receiver is faulty only.
② Set the input memory switch of the REKES receiver onto the position and
push the lock or unlock button on the REKES transmitter.
③ Set the input memory switch of the REKES receiver onto the position and
close all doors.
④ Check the operation of door locking system by pushing the lock and unlock button
on the REKES transmitter.
⑤ This REKES version can use only one transmitter for a vehicle.
2. 2nd method : diagnosis socket use
2-1. Location and terminal arrangement of the diagnosis socket
2-1-1. Vehicle was made before 1998 : engine room left inside (near the fuse box)
[Terminal arrangement]
2 1 1. Ground 8. Blank
3
2. Ignition switch ON 9. Full time T/C
7 6 5 4 3. Power supply B+ (12V) 10. Blank
4. REKES input memory 11. Cruse control
5. Engine RPM(Gasoline) 12. Blank
11 10 9 8
6. Part time T/C 13. ABS
14 7. STICS 14. Engine ECU
13 12
This service bulletin is intended for internal use only. All information, illustrations and specifications contained in this bulletin are
based on the latest product information available at the time of issue.
International A/S & parts team
2-1-2. Vehicle was made after 1998 : engine room left inside (near the fuse box)
[Terminal arrangement]
Tel: 82-31-610-1400
Fax: 82-31-610-3373
Printed in Korea ISB-2001004
E-mail:sykim1@smotor.com SSANGYONG MOTORS COMPANY Page No: 4 of 6
1. Ground 11. Blank
1 2 3 4 2. Ignition switch ON 12. Blank
3. Power supply B+ (12V) 13. ABS
5 6 7 8 9 10 11 12 4. REKES input memory 14. Engine ECU
13 14 15 16 17 18 19 20 5. Engine RPM (Gasoline) 15. Full time T/C
6. Part time T/C 16. Immobilizer
7. STICS 17. Blank
8. Blank 18. Auto T/M (BTRA-TCU)
9. Blank 19. Blank
10. Air bag 20. ECS
2-1-3. Musso 2001 model year (V.I.N. 247012~) : under the dashboard (driver side)
5. Ground
16 15 14 13 12 11 10 9 6. STICS
8 7 6 5 4 3 2 1 7. Immobilizer
8. ABS
9. Air bag
10. Blank
[Terminal arrangement] 11. Blank
12. Full time T/C
1. ECS 13. Full & Part time T/C ,TOD
2. Ignition switch ON 14. Auto T/M (BTRA-TCU)
3. REKES input memory 15. Blank
4. Ground 16. Power supply B+ (12V)
2-2. Input memory procedure : in condition of taking the key out
2-2-1. Old version receiver (~ Apr.19,1997)
① Replace the REKES receiver with a new one and connect the wiring connector when
the REKES receiver is faulty only.
② DC 5V current supply between terminal no.1(ground) and no.4(REKES input memory)
on the diagnosis socket in engine room.
③ Push the lock or unlock button on the REKES transmitter.
④ Input memory and close all doors.
⑤ Check the operation of door locking system by pushing the lock and unlock button
on the REKES transmitter.
This service bulletin is intended for internal use only. All information, illustrations and specifications contained in this bulletin are
based on the latest product information available at the time of issue.
International A/S & parts team
2-2-2. New version receiver (Apr.20,1997 ~)
① Replace the REKES receiver with a new one and connect the wiring connector when
the REKES receiver is faulty only.
Tel: 82-31-610-1400
Fax: 82-31-610-3373
Printed in Korea ISB-2001004
E-mail:sykim1@smotor.com SSANGYONG MOTORS COMPANY Page No: 5 of 6
② ◆ Except the Musso 2001 model year
→ Connect the terminal no.3(power supply B+,12V) and terminal no.4(REKES input memory)
which are on the diagnosis socket in engine room with service lead wire.
◆ Musso 2001 model year only
→ Connect the terminal no.3(REKES input memory) and terminal no.16(power supply B+,12V)
which are on the diagnosis socket in engine room with service lead wire.
③ Push the lock or unlock button on the REKES transmitter.
④ Input memory and close all doors.
⑤ Check the operation of door locking system by pushing the lock and unlock button
on the REKES transmitter.
3. Part no. index
3-1. Transmitter assy-REKES
8715005001X : Ssangyong logo (Jul.01,1993 ~ Jun.30,1994)
8715005000 : Ssangyong logo (Jul.01,1994 ~ Mar.29,1999)
8715005001 : Daewoo logo (Mar.30,1999 ~)
8715005010 : Ssangyong logo (Mar.30,1999 ~)
8715005800 : Daewoo logo, with EU regulation (Nov.30,1998 ~ Mar.29,1999)
8715005810 : Ssangyong logo, with EU regulation (Mar.30,1999 ~)
3-2. Receiver-REKES
8716105001X (Jul.01,1993 ~ Jun.30,1994)
8716105000 (Jul.01,1994 ~ )
8716105800Z : with EU regulation (Nov.30,1998 ~ Mar.29,1999)
8716105800 : with EU regulation (Mar.30,1999 ~)
This service bulletin is intended for internal use only. All information, illustrations and specifications contained in this bulletin are
based on the latest product information available at the time of issue.
International A/S & parts team
Tel: 82-31-610-1400
Fax: 82-31-610-3373
Printed in Korea ISB-2001004