OWON Product Catalogue v3.3.6
OWON Product Catalogue v3.3.6
Product Catalogue
Spectrum Analyzers
Digital Storage Oscilloscopes
Arbitrary Waveform Generators
Programmable DC Power Supplies
PC Oscilloscopes
Digital Multimeters
WWW.OWON.COM.CN
CONTENTS About
- Digital Storage Oscilloscope
Since 1990, Lilliput steps into the electronics product industr y, its 1st product series is a mini color LCD.
02 XDS Series - your powerful n-in-1 on-site measurement station
09 TDS Series - Touch Screen Digital Storage Oscilloscope Through 2 decades' of efforts, Lilliput gradually grew to be a group corporation, covering 3 product lines -
10 AS Series Oscilloscope mini color LCD, test and measurement equipment, and home energy management system.
- PC Oscilloscope
11 VDS6000 Series - PC Oscilloscope OWON’s products can be found in Asia, North America, Europe, South America, Oceania, and Africa, with
- Spectrum Analyzer
16 XSA1000TG Series - Spectrum Analyzer
- Waveform Generator
20 XDG2000 Series - Dual-channel Arbitrary Waveform Generator
- Digital Multimeter
27 XDM2041 - Bench-type Digital Multimeter
High Voltage Probe 43 37 ODP Series - Single Channel Linear DC Power Supply
01
yourpowerfuln-in-1on-sitemeasurementstation yourpowerfuln-in-1on-sitemeasurementstation
Digital Storage Oscilloscope
1 .XDS series introduce 12 / 14 bits hardware ADC, the precision is 16/64 times against other oscilloscope on market.
Equipping with OWON’s original magnifier function, it can obser ve the signal low down to 31.25μV/div
(XDS3202A, XDS3102AP).
8. its built-in WiFi module facilitates mobile device 9 . its multi-point touchscreen improves operation efficiency
connecting with XDS series product, to get access considerably
to remote control, together with simultaneous
measurement result display
WiFi
02 03
yourpowerfuln-in-1on-sitemeasurementstation
Digital Storage Oscilloscope
Model XDS3062A XDS3102A XDS3102AP* XDS3202A* XDS3102 XDS3202E XDS3202* XDS3302* Model XDS3064E XDS3104E XDS3064AE XDS3104AE XDS3104A XDS3104 XDS3204AE XDS3204E
Bandwidth 60MHz 100MHz 100MHz 200MHz 100MHz 200MHz 300MHz Bandwidth 60MHz 100MHz 60MHz 100MHz 200MHz
Channel 2+1 (external) Channel 4
Sample Rate 1GS/s 1GS/s 2GS/s 2.5GS/s Sample Rate 1GS/s
Vertical Resolution (A/D) 12 bits 14 bits 8 bits Vertical Resolution (A/D) 8 bits 14 bits 8bits 14 bits 8bits
Record Length 40M Record length 40M
Waveform Refresh Rate 75,000 wfms/s Waveform Refresh Rate 45,000 wfms/s 70,000wfms/s
2ns/div - 1000s/div 1ns/div - 1000s/div 2ns/div - 1000s/div 1ns/div - 1000s/div Horizontal Scale (s/div)) 2ns/div - 1000s/div, step by 1 - 2 - 5 1ns/div - 1000s/div, step by 1 - 2 - 5
Horizontal Scale
step by 1 - 2 - 5 Input Impedance 1MΩ ± 2%, in parallel with 15pF ± 5pF
Input Impedance 1MΩ ± 2 %, in parallel with 15pF ± 5pF; (*50Ω ± 2%) Vertical Sensitivity 1mV/div - 10V/div (at input)
Vertical Sensitivity 1mV/div - 10V/div (at input) DC Gain Accuracy ±3%
DC Gain Accuracy ±1.5% ±3% Sample Rate / Relay Time ±2.5ppm (type, Ta=+25℃)
Sample Rate/Relay Time ±1ppm(type,Ta=+25℃) Trigger Type Edge, Video, Pulse, Slope, Runt, Windows, Timeout, Nth Edge, Logic, I2C, SPI, and RS232/UART
Trigger Type Edge, Video, Pulse, Slope, Runt, Windows, Timeout, Nth Edge, Logic, I2C, SPI, and RS232/UART Trigger Type (optional) CAN
Trigger Type (optional) CAN Bus Decoding(optional) I2C, SPI, RS232/UART, CAN
Bus Decoding (optional) I2C, SPI, RS232/UART, and CAN +, -, *, / ,FFT, FFTrms, Intg, Diff, Sqrt, User Defined Function, digital filter
Waveform Math
+, -, x, ÷, FFT, FFT rms, Intg, Diff, Sqrt, User Defined Function, digital filter (low pass, high pass, band pass, band reject)
Waveform Math
(low pass, high pass, band pass,bandreject)
Vpp, Vavg, Vrms, Freq, Period, Week RMS, Cursor RMS, Vmax, Vmin, Vtop, Vbase, Vamp,
Vpp, Vavg, Vrms, Freq, Period, Week RMS, Cursor RMS, Vmax, Vmin, Vtop, Vbase, Vamp, Overshoot, Phase, Overshoot, Phase, Preshoot, Rise Time, Fall Time,+Width, -Width, +Duty, -Duty, Duty Cycle,
Automatic Automatic Measurement
Preshoot, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, Duty Cycle, Delay A→B , Delay A→B , Delay A→B , Delay A→B , Phase A→B , Phase A→B , +Pulse Count, -Pulse Count, Rise Edge
Measurement Count, Fall Edges Count, Area, Cycle Area
+Pulse Count, -Pulse Count, Rise Edge Count, Fall Edge Count
Communication Interface USB, Pass/Fail, LAN, VGA(optional) Communication Interface USB host, USB device, Trig Out (P/F), LAN, and VGA (optional)
Frequency Counter √ Frequency Counter √
Power Supply 100V-240VAC, 50/60Hz, CATⅡ<15W Power Supply 100V - 240V AC, 50/60Hz, CAT II
Fuse 2A, Tclass, 250V Fuse 2A, T class, 250V
Dimension (WxHxD) 340x177x90(mm) Batter y (optional) 3.7V, 13200mA
Device Weight 2.6kg Dimension (W x H x D) 340mmx177mmx90mm
Device Weight 2.8kg
Standard Waveform Sine, Square, Pulse, Ramp mobile app accessible via
scanning QR code
Exponential Rise, Exponential Fall, Sin(x)/x, Step Wave, Noise, and others, total 46 built-in
Arbitrar y Waveform
waveforms, and user-defined arbitrar y waveform
10M
Digital Storage Oscilloscope
Model SDS6062 SDS7072 SDS7102 SDS7202 SDS8102 SDS8202 SDS8302 SDS9302 Model SDS5032E SDS5052E SDS6062E SDS7072E SDS7102E SDS7122E
Bandwidth 60MHz 70MHz 100MHz 200MHz 100MHz 200MHz 300MHz Bandwidth 30MHz 50MHz 60MHz 70MHz 100MHz 125MHz
Sample Rate 500MS/s 1GS/s 2GS/s 2.5GS/s 3.2GS/s Sample Rate 500MS/s 1GS/s
Rise Time ≤5.8ns ≤5ns ≤3.5ns ≤1.7ns ≤3.5ns ≤1.7ns ≤1.17ns Input Impedance 1MΩ ± 2%, in parallel with 15pF ± 5pF
Record Length 10M Horizontal Scale (s/div) 5ns/div - 100s/div, step by 1 - 2 - 5 2ns/div - 100s/div, step by 1 - 2 - 5
Display 8”color LCD, 800 x 600 pixels Vertical Sensitivity 5mV/div - 5V/div (at input) 2mV/div - 10V/div (at input)
Input Impedance 1MΩ ± 2%, in parallel with 15pF ± 5pF Vertical Resolution (A/D) 8 bits (2 channels simultaneously)
Vertical Sensitivity 2mV/div - 10V/div Trigger Type Edge, Pulse, Video, Slope, and Alternate
Vertical Resolution (A/D) 8 bits (2 channels simultaneously) Digital Filtering / low-pass, high-pass, band-pass, and band-reject
Waveform Storage 15 waveforms Communication Interface USB host, USB device, Pass / Fail, LAN, and VGA (optional)
Measuring Current Range 100mA/V - 1KA/V Dimension (W x H x D) 348 x 170 x 78 (mm)
Communication Interface USB host, USB device, Pass / Fail, LAN, VGA (optional), and RS232 (optional) Device Weight 1.50 kg
Batter y (optional) 7.4V, 8000mA Specifications subject to change without prior notice.
Power Cord CD Rom Quick Guide USB Cable Probe Probe Adjust Batter y Soft Bag
(optional) (optional) Power Cord CD Rom Quick Guide USB Cable Probe Probe Adjust Soft Bag
(optional)
06 07
SDS1000SSeriessuper-economicaltypedigitalstorageoscilloscope TDSSeriesTouchScreenDigitalStorageOscilloscope
Digital Storage Oscilloscope
Model SDS1022 SDS1052 SDS1102 SDS1202 Model TDS7074 TDS7104 TDS8104 TDS8204
Bandwidth 20MHz 50MHz 100MHz 200MHz Bandwidth 70MHz 100MHz 200MHz
Channel 2 Channel 4
Horizontal Scale (s/div) 5ns/div - 100s/div, step by 1 - 2 - 5 2ns/div - 100s/div, step by 1 - 2 - 5 Waveform Capture Rate 50,000 wfms/s
Display 7" color LCD, 800 x 480 pixels Display 8" color LCD
Input Impedance 1MΩ ± 2%, in parallel with 20pF±5pF Input Impedance 1MΩ ± 2%, in parallel with 15pF ± 5pF ; 50Ω ± 1%
Record Length 10K Record Length 7.6M
Sample Rate / Relay Time ±100ppm Horizontal Scale (s/div) 2ns/div - 100s/div, step by 1 - 2 - 5
Vertical Resolution (A/D) 8 bits (2 channels simultaneously) Vertical Resolution (A/D) 8 bits (4 channels simultaneously)
Vertical Sensitivity 5mV/div - 5V/div (at input) Vertical Sensitivity 2mV/div - 10V/div (at input)
Trigger Type Edge, Video Trigger Type Edge, Pulse, Video, and Slope
Vpp, Vavg, RMS, Frequency, Period, Vmax, Vmin, Vtop, Vbase, Width, Overshoot, Vpp, Vavg, Vrms, Freq, Period, Vmax, Vmin, Vtop, Vbase, Vamp, Overshoot, Preshoot,
Automatic Measurement Automatic Measurement
Pre-shoot, Rise time, Fall time, +Width, -Width, +Duty, -Duty, Delay A→B , Delay A→B Rise Time, Fall Time, Delay A→B , Delay A→B , +Width, -Width, +Duty, -Duty
+Accessories The accessories subject to final deliver y. +Accessories The accessories subject to final deliver y.
Meeting your needs
Power Cord CD Rom Quick Guide USB Cable Probe Probe Adjust Soft Bag Power Cord CD Rom Quick Guide USB Cable Probe Probe Adjust Soft Bag
(optional) (optional)
08 09
AS101&AS201Oscilloscope VDS6000SeriesPCOscilloscope
Digital Storage Oscilloscope
PC Oscilloscope
The best choice to replace an analogue oscilloscope + Dual-channel, ultra-thin body design
+ The simple control panel is similar to an analogue oscilloscope + 100MHz bandwidth, and max. 1GSa/s real-time sampling rate
+ Bandwidth : 10MHz(AS101),20MHz(AS201) + Standard built-in 5MHz signal generator
+ Sample rate : 100MS/s + 8-bit, 12-bit, 14-bit vertical resolution,
+ 130,000 wfms/s waveform capture rate, easily capturing more accurate measurement
exceptional and low probability events + Max. 10M record length
+ 3.7" Colored LCD + Standard SCPI protocol supported, LabVIEW supported
+ Compact case + Secondary development supported on Windows, Linux,
Android, and iOS platform
+ Support Wi-Fi Communication
Model AS101 AS201
Bandwidth DC:0-10MHz, AC: 10 Hz-10MHz DC:0-20MHz, AC: 10 Hz-20MHz
Channel 1
Sample Rate 100MS/s
Horizontal system Scanning speed (S/DIV) 0.05us/DIV - 0.1s/DIV,step by 1 - 2 - 5
Trimming Ratio ≥2.5:1
Sensitivity 5 mV/DIV~10 V/DIV
Model VDS6102 VDS6102A
Displacement ±10DIV
Bandwidth 100MHz
Vertical system Low Frequency ≥10 Hz (at input, AC coupling, -3 dB)
Rise time (at input, Typical) ≤30 ns Channel 2Channel+Signal generator
Trimming Ratio ≥2.5:1 Sample Rate 1GS/s
Input coupling DC, AC , Ground Horizontal Scale (s/div) 2ns/div - 100s/div, step by 1 - 2 - 5
Input impedance 1 MΩ±2%, in parallel with 20 pF±5 pF
Record Length 10M
Max. input voltage 400V (DC+AC, PK - PK)
Input Impedance 1MΩ ± 2%, in parallel with 10pF ± 5pF
X-Y Model
Sensitivity X:0.5V/DIV Y:0.1V/DIV - 1V/DIV Sample rate/Relay time accuracy ±100ppm
Bandwidth(-3dB) DC: 0 - 1MHz AC: 10Hz - 1MHz Max Input Voltage 40V(DC + AC peak)
Trigger
Vertical Sensitivity 5mV/div - 5V/div
Trigger level range ±4 DIV from the screen center
Vertical Resolution 8 bits 8 bits, 14bits
Trigger level Accuracy (typical) ±0.3 DIV
Trigger Sources Int, Line, Ext Trigger Type Edge, Pulse, Video, Slope, and Alternate
Trigger Mode Norm, AUTO, TV Vpp, Vavg, Vrms, Frequency, Period, Vmax, Vmin, Vtop, Vbase, Vamp, Overshoot,
Automatic Measurement
Edge trigger Rising, Falling Preshoot, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, DelayA→B , DelayA→B
Video Trigger Support standard NTSC, PAL and SECAM broadcast systems
Waveform Math +, -, *, /, FFT
Sample Rate / Relay Time ±100ppm
Trigger lock support Communication Interface USB(Type-C), LAN, WIFI(optional)
Ext. Trigger Input Impedance 1 MΩ2%, in parallel with 20 pF±5 pF Power Supply ≤8W
Ext. Trigger Max. Input Voltage 400Vpp Dimension (W x H x D) 190 × 18 × 120 (mm)
Trigger Output of the probe compensator
Device Weight 0.3 kg
Output Voltage (Typical) Square, 0.5Vpp±2%
Specifications subject to change without prior notice.
Frequency (Typical) Square wave of 1 kHz(±1%)
Display 3.7" Colored LCD (Liquid Crystal Display) +Accessories The accessories subject to final deliver y.
10 11
VDSSeriesPCOscilloscope VDS2064&VDS3104AutomotiveDiagnosticsKits
PC Oscilloscope
+ Up to 100MHz bandwidth,
Model VDS2064 VDS3104
and max 1GS/s real-time sample rate
Bandwidth 60MHz 100MHz
+ Max 10M record length
Channel 4
+ Friendly UI : FFT, or X-Y, and waveform 2 views
Sample Rate 1GS/s
displayed on the same screen
Record Length 5M
+ Multi-trigger option :
edge, video, slope, pulse, and alternate
+ USB isolation - less signal interference,
more PC protection
1. Support waveform record and replay 2. Support 78 reference waveforms for
+ USB bus powering, and LAN remote control (optional)
function, and circle recording automotive diagnostic
+ Ultra-thin body design, easy portability
2ns/div - 100s/div,
Horizontal Scale (s/div) 5ns/div - 100s/div, step by 1 - 2 - 5
step by 1 - 2 - 5
Vpp, Vavg, Vrms, Frequency, Period, Vmax, Vmin, Vtop, Vbase, Vamp, Overshoot,
Automatic Measurement
Preshoot, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, DelayA→B , DelayA→B
Communication Interface USB2.0 (isolation) USB2.0 USB2.0;LANCommunication Interface(optional) High-tension BNC plug to alligator
BNC to 4 mm test lead USB cable
ignition pickup clips cable
Power Supply ≤2.5W ≤6.5W
Probe Probe Adjust Power Cord* CD Rom Quick Guide USB Cable Adapter* Silicon Gel Case Soft Bag
(optional)
* Power cord and adapater only available for models with LAN port.
12 13
HDS-NSeriesDualChannelHandheldOscilloscope HDSSeriesSingleChannelHandheldOscilloscope
Handheld Digital Storage Oscilloscope
FFT FFT
- -
WAVE WAVE
USB RECORD Li - ion USB RECORD Li - ion
Vpp, Vavg, Vrms, Frequency, Period, Vmax, Vmin, Vtop, Vbase, Vamp, Overshoot, Preshoot, Trigger Type Edge, Video
Automatic Measurement
Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, DelayA→B , DelayA→B
Vpp, Vavg, Vrms, Frequency, Period, Vmax, Vmin, Vtop, Vbase, Vamp, Overshoot, Preshoot,
Automatic Measurement
Waveform Math +,-,*,/, FFT Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, DelayA→B , DelayA→B
3 DCV: 400mV - 1000V DCA: 40mA - 10A 400Ω 3 DCV: 400mV - 1000V DCA: 40mA - 10A 400Ω
3 4 digits (max 4000 count) √ √ 3 4 digits (max 4000 count) √ √
ACV: 4V - 750V ACA: 40mV - 10A 4KΩ - 40MΩ ACV: 4V - 750V ACA: 40mV - 10A 4KΩ - 40MΩ
Specifications subject to change without prior notice. Specifications subject to change without prior notice.
+Accessories The accessories subject to final deliver y.
+Accessories The accessories subject to final deliver y.
Power Cord CD Rom Quick Guide USB Cable Probe Probe Adjust Multimeter Adapter 5V, 1KHz
Lead Output Power Cord CD Rom Quick Guide USB Cable Probe Probe Adjust Multimeter Adapter 5V, 1KHz
Lead Output
Meeting your needs
14 15
XSA1000SeriesSpectrumAnalyzer
Spectrum Analyzer
Trace functions Clear write, Max Hold, Min Hold, View, Blank, Average
level unit dBm,dBuW,dBpW,dBmV,dBuV, W,V
Communication Port USB HOST, USB DEVICE, LAN, earphone port, VGA, REF
3. Phase noise: <-80 dBc/Hz @1 GHz @ 30 KHz offset Display 10.4 inch TFT LCD
Excellent phase noise performance -
Specifications subject to change without prior notice.
<-80dBc/Hz @30KHz enables users to evaluate most synthesizers
and signal generators.
+Accessories
The accessories subject to final deliver y.
Optional Accessories
+ Frequency Range from 9 kHz up to 3.6 GHz Provide EMC test function
+ -160dBm Displayed Average Noise Level (requires optional software)
+ Phase Noise -80dBc/Hz @1Gz and offset at 10kHz
Built-in more than 200 mainstream EMC test
+ Total Amplitude Accuracy <1.5dB standards and regulations templates. The
+ 10Hz Minimum Resolution Bandwidth (RBW) user selects the corresponding template, and
the software automatically sets the spectrum
+ Standard GPS receiver, optional antenna, the latitude/longitude analyzer and records the test data. The data
information and test information can be recorded and regulations can be compared on the
same screen. Users can also customize
+ Li-ion battery, operating life up to 4 hours, easy replacement, regulations for comparative analysis.
you can purchase extra batteries for longer test time.
+ 8-inch (1024*768) IPS LCD touchscreen, built-in light sensor to
adjust the screen backlight according to the environmental light.
With a Carrying case (optional), Frequency Range 9kHz-1.6 GHz 9kHz-3.6 GHz
you can free your hands and make Frequency Resolution 1Hz
on-site work more convenient. Aging rate <1ppm/Year
Phase Noise (fc=1GHz) <-80 dBc/Hz @10 kHz offset
Resolution Bandwidth (-3dB) (RBW) 10 Hz to 500 kHz (1-10 steps by sequence), 1 MHz, 3 MHz
(Input Attenuation= 0 dB, Sample Detector, Trace Average ≥20, 20℃ to 30℃,
Display Average Noise Level (DANL)
Input Impedance=50 Ω, RBW normalizes to 1Hz)
Trace functions Clear write, Max Hold, Min Hold, View, Blank , Average
Pass/Fail function level unit dBm,dBuW,dBpW,dBmV,dBuV, W,V
Quickly determine if the test results pass
100 kHz-3.6 GHz (Tracking generator)
Tracking generator (-TG Model) 100 kHz-1.6 GHz
35 MHz-3.6 Ghz (signal generator)
Power Cord USB Cable Adapter Quick Guide CD Rom Metal Case GPS antenna Soft Bag
(optional)
18 19
XDG2000SeriesDual-channelArbitraryWaveformGenerator
Type AM, DSB-AM, FM, PM, ASK, FSK, PSK, BPSK, QPSK, 3FSK, 4FSK, OSK, PWM, SUM
Frequency Counter
Function Frequency, period, +width, -width, +duty, and -duty
Frequency Range 100mHz - 200MHz
Frequency Resolution 7 digits
Rich analog and digital modulation Build-in 152 arbitrary waveforms Input / Output
frequency counter, external modulation input, external trigger input,
Input mode
Internal clock output, external reference clock input / output
Communication
USB Host, USB Device,LAN,RS232 (optional)
Interface
Mechanical specifications
Size 340mm x 177mm x 90mm
Weight 2.3kg
Specifications subject to change without prior notice.
20 21
XDG3000SeriesDual-channelArbitraryWaveformGenerator
Waveform Generator
+ SCPI, and LabVIEW supported Sine 1μHz - 250MHz 1μHz - 200MHz 1μHz - 160MHz 1μHz - 100MHz 1μHz - 80MHz
Amplitude
Modulation
Type AM, FM, PM, PWM, FSK, 3FSK, 4FSK, PSK, OSK, ASK, BPSK, Sweep, and Burst
Frequency Counter
Function Frequency, Period, +Width, -Width, +Duty, and -Duty
Rich analog and digital modulation counter, external modulation input, external trigger input,
Build-in 152 arbitrary waveforms Type
external reference clock input / output
Mechanical
Dimension (W x H x D) 340 x 177 x 90 (mm)
Device Weight 2.50 kg
22 23
AG-SSeriesSingle-channelArbitraryWaveformGenerator
Waveform Generator
+ Advanced DDS technology, upto 10MHz frequency output Model AG4081 AG4101 AG4121 AG4151
+ 400MS/s sample rate, and 1μHz frequency resolution Channel single + trigger
+ Vertical Resolution : 14 bits, and 8K arb waveform length Frequency Output 80MHz 100MHz 120MHz 150MHz
AM, FM, PM, FSK, Sweep, and Burst Arbitrar y Waveform Sine, Square, Pulse, Ramp, Noise
+ SCPI, and LabVIEW supported Exponential Rise, Exponential Fall, Sin(x)/x, Step Wave, and others, total 45 built-in waveforms,
Arbitrar y Waveform
and user-defined arbitrar y waveform
+ 4'' high resolution (480 x 320 pixels) LCD
Frequency (resolution 1μHz)
+ could work with OWON SDS Series DSO smoothly Sine 1μHz - 80MHz 1μHz - 100MHz 1μHz - 120MHz 1μHz - 150MHz
Square 1μHz - 40MHz 1μHz - 50MHz
Model AG051 AG051F AG1011 AG1011F
Pulse 1μHz - 2 0 MHz 1μHz - 25MHz
Channel single + trigger
Ramp 1μHz - 1MHz
Frequency Output 5MHz 10MHz
Noise 50MHz(-3dB,type)
Sample Rate 125MS/s
Wave Length 2 - 1M pts
Vertical Resolution 14 bits
Amplitude
Waveform
Amplitude (50Ω),10mVpp-20 Vpp
10mVpp-10 Vpp (high impedance)
Standard Waveform Sine, Square, Pulse, Ramp, Noise
Modulation (optional)
Exponential Rise, Exponential Fall, Sin(x)/x, Step Wave, and others, total 45 built-in waveforms,
Arbitrar y Waveform Modulation
and user-defined arbitrar y waveform AM, FM, PM, FSK, PWM, Sweep, Burst
Waveform
Frequency (resolution 1μHz)
Modulation
Sine 1μHz - 5MHz 1μHz - 10MHz 2mHz to 20.00KHz (FSK 2 m Hz - 100KHz)
Frequency
Square 1μHz - 5MHz
Input / Output
Pulse 1μHz - 5 MHz
external modulation input,
Ramp 1μHz - 1MHz
Type external trigger input / output,
Noise 5MHz(-3dB,type)
external reference clock input / output
Wave Length 2 - 8K pts
Communication
Amplitude USB host, USB device, LAN , RS232 ( optional )
Interface
Amplitude (50Ω), 1mVpp-25 Vpp(high impedance)
1mVpp-12.5 Vpp
Mechanical
Modulation (optional)
Dimension (W x H x D) 235 × 110 × 295 (mm)
Modulation
/ AM, FM, PM, FSK, Sweep, Burst / AM, FM, PM, FSK, Sweep, Burst Device Weight 3kg
Waveform
Specifications subject to change without prior notice.
Modulation 2mHz to 20.00KHz 2mHz to 20.00KHz
/ /
Frequency (FSK 2 m Hz - 100KHz) (FSK 2 m Hz - 100KHz)
+Accessories The accessories subject to final deliver y.
Counter Specification(optional)
Function Frequency, period, positive Pulse width, Duty cycle
Frequency Range Single channel: 100 mHz - 200 MHZ
Input / Output
Meeting your needs
Communication
USB device
Interface
24 25
AGSeriesDual-ChannelArbitraryWaveformGenerator XDM2041Bench-typeDigitalMultimeter
Digital Multimeter
+ 3.7 inch (480x320) high resolution LCD
+ Up to 300MS/s sample rate, and 1μHz frequency resolution + 55,000 counts
+ Vertical Resolution : 14 bits, up to 1M arb waveform length + Up to 65 readings per second
+ Comprehensive waveform output : 5 basic waveforms, + True RMS AC voltage / current measurement
+ Dual line display supported
and 45 built-in arbitrary waveforms
+ Trend analysis accessible in chart mode
+ Comprehensive modulation functions : + SCPI support
AM, FM, PM, FSK, PWM, Sweep, and Burst
+ High-accuracy frequency counter integrated,
supported range 100mHz - 200MHz
+ SCPI, and LabVIEW supported
+ 4 inch high resolution (480 x 320 pixels) LCD
Basic Function Measurement Range Optimal Accuracy
+ could work with OWON SDS Series DSO smoothly
DC Voltage 50.000mV-1000.0V 0.025%+5
Model AG1012 AG1012F AG1022 AG1022F AG2052F AG2062F
True RMS AC Voltage 500mv-750v 0.5%+30
Channel dual
500uA/5000uA/50mA/500mA 0.15%+20
Frequency Output 10MHz 25MHz 50MHz 60MHz AC Voltage
5A/10A 0.5%+10
Sample Rate 125MS/s 300MS/s
500uA-500mA 0.5%+20
Vertical Resolution 14 bits True RMS AC Current
5A-10A 1.5%+20
Waveform
500Ω 0.1%+10
Standard Waveform Sine, Square, Pulse, Ramp, Noise
5KΩ/50KΩ/500KΩ 0.1%+5
Exponential Rise, Exponential Fall, Sin(x)/x, Step Wave, and others, total 45 built-in Resistance
Arbitrar y Waveform 5MΩ 0.25%+5
waveforms, and user-defined arbitrar y waveform
50MΩ 1%+10
Frequency (resolution 1μHz)
500Ω 0.1%+10
Sine 1μHz - 10MHz 1μHz - 25MHz 1μHz - 50MHz 1μHz - 60MHz Four-wire resistance
5KΩ/50KΩ 0.1%+5
Square 1μHz - 5MHz 1μHz - 5MHz 1μHz - 25MHz 1μHz - 30MHz
Diode 3.0000 V
Pulse 1μHz - 5MHz 1μHz - 5MHz 1μHz - 10MHz 1μHz - 15M Hz
Continuity 1000 Ω
Ramp 1μHz - 1MHz
Frequency 10.000Hz–60MHz ±(0.2%+8)
Noise 25MHz (-3dB, type)
50nF-500uF 2.5%+5
Wave Length 2 - 8K pts 2 - 1M pts Capacitance
5mF-50mF 5%+8
Amplitude
Temperature K-type, T100
Amplitude 1 mVpp - 10 Vpp (50Ω), 1 mVpp - 20 Vpp ( h igh impedance)
Display 55,000
Modulation
Logging Duration 15ms-9999s
Modulation Waveform / AM, FM, PM, FSK, Sweep, Burst AM, FM, PM, FSK, PWM, Sweep, Burst
Logging Length 1,000pts
Modulation Frequency / 2mHz to 20.00KHz (FSK 2mHz - 100KHz)
General
Mechanical
Communication Interface RS232
Dimension (W x H x D) 235 × 110 × 295 (mm)
Dimensions (W×H×D) 235 x 110 x 295 (mm)
Device Weight 3kg
Device Weight Approximately 3kg
Power Amplifier Module (optional)
Specifications subject to change without prior notice
Bandwidth (at full power) DC-100kHz Max Output Power 10W Max Input Voltage 22Vpp
Specifications subject to change without prior notice.
+ 4 inch 480 x 320 pixels high resolution LCD Model XDM3051 XDM3041
+ 5 1/2 digits and 4 1/2 digits resolutions Function Measurement Range Optimal Accuracy Measurement Range Optimal Accuracy
+ reading rates up to 150 readings/s Diode Test 2.0000V 0.05 ± 0.01 3.0000V 0.5 ± 0.01
+ true RMS AC voltage / current measurement Continuity 2000Ω 0.05 ± 0.01 1000Ω 0.5 ± 0.01
+ dual line display supported Frequency 20Hz - 1MHz 0.01 + 0.003 20Hz - 1MHz 0.01 + 0.003
+ the change trend analysis accessible via special chart mode Period 20Hz - 10KHz 0.01 + 0.003 20Hz - 10KHz 0.01 + 0.003
during recording the measurement value, possible to set the logging duration (min. 5ms), and length, 200 μF 100 μA 1 + 0.5
then get access to chart or table result 10000 μF 1 mA 2 + 0.5
Data-logger Function
Logging
5ms -1000s
Duration
General
Communication
Interface
USB Device / Host, RS232, LAN, and ext. trigger input
Model XDM3051 XDM3041
Function Measurement Range Optimal Accuracy Measurement Range Optimal Accuracy Dimension
235 x 110 x 295 (mm)
200mV-1000V 0.015 ± 0.004 600mV-1000V 0.02 ± 0.01 (W x H x D)
DC Voltage
28 29
OWSeriesMultiinonesmartmultimeter O W16/ O W18Multiinonesmartmultimeter
Digital Multimeter
μA / 600.0μ/6000μ ±(1%+3dig)
AC
mA 60.00mA/600.0mA ±(1%+3dig)
Current
A 10.00A ±(1.5%+3dig)
600.0Ω6.000kΩ60.00kΩ600.0kΩ6.000MΩ ±(0.8%+2dig)
Resistance
60.00MΩ ±(2%+3dig)
NCV (Non-Contact Voltage) Sensor 60.00nF/600.0nF/6.000μ/60.00μ ±(3%+3dig)
Capacitance
600.0μ/6.000mF/60.00mF ±(3%+5dig)
When the non-contact voltage sensor is placed near to a live
conductor, the instrument will beep and flash the row of LEDs Frequency 9.999Hz/99.99Hz/999.9Hz/9.999kHz/99.99kHz/999.9kHz/9.999MHz ±(0.8%+2dig)
on-site temperature test at the top of the display depending on the AC voltage strength.
0.1%-99.9%(typical value:rms=1V,f=1kHz) ±(1.2%+3dig)
Duty Ratio
0.1%-99.9%(≥kHz) ±(2.5%+3dig)
- 50 ℃ - 400℃ ±(2.5%+3dig)
Temperature
-58 ℉ - 752 ℉ ±(4.5%+5dig)
Display 5999
Special Function
Bluetooth Module OW16B, OW18B Auto Ranging √
True RMS √ Auto- / Manual Range Selection √
Diode Test √ Input Protection √
LCD Backlight √ Input Impedance ≥10MΩ
On-off Warning √ 600V CATⅢ (OW16A,OW16B)
functioning as multimeter + datalogger offline recording function - your Safety Compliance
Flashlight OW18A, OW18B 1000V CATⅢ (OW18A,OW18B)
the measured data always updated, and auto- recorded to process analyzer Low-battery Indicator √ NCV √
mobile device, saving labor to do on-site records;
the recoding duration, and sampling duration could be possible to record data into memory, but no need to leave mobile 147mm x 74mm x 49mm (OW16A, OW16B)
device on-site when data-processing, use mobile device to recall Data Hold √ Dimension (W / H / D)
customized, accessible in chart mode, facilitating comparison 190mm x 90mm x56mm (OW18A, OW18B)
the saved data and offline recording
analysis between several multimeters
Relative Measurement √ Weight (without package) 0.29 kg(OW16A, OW16B), 0.32kg(OW18A, OW18B)
30 31
OW18D/EMultiinonemultimeter BluetoothDigitalMultimeter
Digital Multimeter
200.00Ω ±(0.5%+10dig)
2.0000kΩ ±(0.3%+3dig) functioning as multimeter + datalogger remote control supported
Resistance 20.000kΩ200.00kΩ2.0000MΩ ±(0.3%+1dig) the measured data always updated, and auto- recorded to the function activated after
TTS voice pack installed, which voice on
mobile device, saving labor to do on-site records;
20.000MΩ ±(0.5%+1dig) frees the eye-watch, making voice off
the recoding duration, and sampling duration could be on-site measurement more
200.00MΩ ±(5.0%+10dig) customized, accessible in chart mode, facilitating comparison comfortable
analysis between several multimeters
2.0000nF/20.000nF/200.00nF/2.0000μ/20.000μ
Capacitance ±(3.0%+10dig)
200.00μ/2.0000mF/20.000mF
20.000Hz/200.00Hz/2.0000kHz
Frequency ±(0.1%+4dig)
20.000kHz/200.00kHz/2.0000MHz/20.000MHz
- 50 ℃400℃(1℃) ±(1.0%+3℃)
Temperature
-58 ℉~ 752 ℉(1℉) ±(1.2%+6℉)
Display 19999
Frequency Response (40 - 1000) Hz
Sample rate 3 times/second
Special Function
True RMS √ Auto Ranging √
data- saving, recalling, and comparatively analyzing
Diode Test √ LCD Backlight √
CSV format data export supported, the histor y data could be recalled for comparison analysis;
Auto Power-off √ Automatic-manual Range Selection √
with the assistance of chart mode, the measured result more visualized, easier for decision- making
On-off Warning √ Input Protection √
32 33
Multimeter Leads K-typeThermocouple Quick Guide 9V batter y (optional) Alligator Clip (optional)
BluetoothDigitalMultimeter
Digital Multimeter
offline recording function - your process analyzer Capacitance B41T+ Measurement Range Optimal Accuracy
B33+ / B35+ / B35T+ / B41T+ possible to record data into memory, 22.00Hz, 220.0Hz, 22.000kHz, 220.00kHz, 22.00Hz, 2.2000MHz, 22.000MHz ±(0.1%+4dig)
but no need to leave mobile device on-site Frequency
when data-processing, use mobile device to recall the saved data >220MHz
offline data-recording could continue for max 7 days (168 hours)
5.0%-94.9%(typical value: Vrms=1V,f=1kHz) (resolution 0.1%) ±(1.2%+3dig)
Duty Ratio
0.1%-99.9%(≥1kHz) (resolution 0.1%) ±(2.5%+3dig)
Display 21999
Frequency
(40-10000)Hz
Model: D35, D35T, B35T+, D33, B33+ Response
Basic Function 35 Series Measurement Range 33 Series Measurement Range Optimal Accuracy Shift Rate 3times/s
DC 60.00mV/600.0mV/6.000V/60.00V 400.0mV/4.000V/40.00V/400.0V
±(0.5%+2dig)
Voltage 600.0V/1000V 1000V Special Function
9.999Hz/99.99Hz/999.9Hz/9.999kHz 4.999Hz/49,99Hz/499.9Hz/4.999kH
Frequency ±(0.8%+2dig)
99.99kHz/999.9kHz/ 9.999MHz z49.99kHz/49.9kHz/4.999MHz
+Accessories The accessories subject to final deliver y. optional accessories:
0.1%-99.9%(typical value: Vrms=1V, f=1kHz) ±(1.2%+3dig)
Duty Ratio
0.1% -99.9%(≥1kHz) ±(2.5%+2dig)
-50℃-+400℃ ±(2.5%+3dig)
Temperature
-58°F-+752°F ±(4.5%+5dig)
Display 6000 3999 Multimeter K-type Quick Guide Alligator Clip Multi-function Soft Bag
Lead Thermocouple Test Bench
Frequency (40-400)Hz (D35), (excl. D33 / B33 / B33+)
(40-400)Hz
Response (40-1000)Hz (D35T, B35T+)
AC Voltage 220mV,2.2V,22V,220V,750V ±(0.8%+10dig) mobile app accessible via mobile app accessible via
scanning QR code scanning QR code
DC Current 220μA,2200μA,22mA,220mA,20.00A ±(0.5%+10dig)
Meeting your needs
34 35
SP&P4000SeriesSingleLinearDCPowerSupply ODP3031SingleChannelProgrammableDCPowerSupply
Power Supply
up to Full Load. Display Type 3.7 inch colored LCD 4 inch colored LCD
Dimension (W x H x D) 117x 194 x 295 (mm) 250 x 158 x 358 (mm)
Conventional
Device Weight 3 kg 5.6 kg 5.8 kg 7 kg
display example*
Communication Interface RS232 USB Device (optional), RS232 USB Device, RS232
The specifications based upon the instrument having run for at least 30 minutes continuously, under the specified operating environment.
36 Power Cord CD Rom Quick Guide USB Cable Fuse RS232 Cable Test Leads RS232 to USB Module 37
(ODP3031) (SP & P4000 Series ) (optional) (optional)
ODPSeriesDualChannelProgrammableDCPowerSupply
Power Supply
The specifications based upon the instrument having run for at least 30 minutes continuously, under the specified operating environment.
max
378W
power output
+ Two independent controllable channels + sense Model ODP3032 ODP3122 ODP6062
(ODP3122, ODP6062) Voltage ≤0.01% + 3mV ≤0.01% + 3mV
Line Regulation
+ Two independent controllable channels + fixed(ODP3032) Current ≤0.1% + 3mA ≤0.01% + 3mA
+ Max output resolution : 1mV / 1mA Voltage ≤0.01% + 3mV ≤0.01% + 3mV
Load Regulation
+ Low ripples / low noise Current ≤0.2% + 3mA ≤0.01% + 3mA
to monitor the changing status of powering system, displaying recorded data in chart. 10 K groups (of voltage, current and power
Data Recording /
data) recording capacity
Power Cord CD Rom Quick Guide USB Cable Fuse Test Leads
Model ODP3032 ODP3122 ODP6062 (optional)
38 39
ODPSeriesThripleChannelProgrammableDCPowerSupply
Power Supply
+ Three independent controllable channels The specifications based upon the instrument having run for at least 30 minutes continuously, under the specified operating environment.
max
+ Max output resolution : 1mV / 1mA
378W
power output
Model ODP3033 ODP3053 ODP3063 ODP6033
+ Low ripples / low noise Channel CH1 CH2 CH1 CH2 CH1 CH2 CH1 CH2 CH3
+ Up to 100 group timers Voltage 0-30V 0-30V 0-30V 0-60V 0-6V
+ Multi- working mode : individual, parallel, and series (0℃ - 40℃) Current 0-3A 0-5A 0-6A 0-3A 0-3A
+ Over-voltage / Over-current protection Over Current Protection 3.1A 5.1A 6.1A 3.1A 3.1A
Voltage ≤0.01%+3mV
Line Regulation
Current ≤0.01%+3mA
+ 4 inch high resolution (480 x 320 pixels) LCD
Voltage 1mV
+ Multi- CI: USB, RS232, and LAN Settings Resolution
Current 1mA
+ Auto-cooling system
Voltage 1mV
+ SCPI, and LabVIEW supported Read Back Resolution
Current 1mA
1Mpts
Storage
Model Channel Max Output Power Output Range ProgrammableOutput 100 groups
ODP3033 198W 30V / 3A || 30V / 3A, 6V / 3A Time Setting second
ODP3053 318W 30V / 5A || 30V / 5A, 6V / 3A Data Recording 10K groups (of voltage, current and power data ) recording capacity
3 (independent controllable channel)
ODP3063 378W 30V / 6A || 30V / 6A, 6V / 3A Working Temperature 0-40℃
Power Cord CD Rom Quick Guide USB Cable Fuse Test Leads
(optional)
40 41
DifferentialProbe HighVoltageProbe
Probe
Bandwidth(-3dB) 100MHz 50MHz DC-100MHz(-3dB) Max.Working DC+AC(peak)40KVCATII DC+AC(peak)18KVCATII Max.Working DC: 0-10KV
Voltage AC(rms):27KVCATII AC(rms):12KVCATII Voltage AC(rms): 0~7KV; Vpp: 0-20KV(Pulse)
AttenuationRatio 1:1000;1:100
Thepulse <27KVp-p <12KVp-p Bandwidth(-3dB) 50MHz
Accuracy ±1%
Max.Loading noise >60dB(1KHz),>50dB(1MHz)
Impedance 10MΩ//2PF 4MΩ//2PF 43μA 90μA
Current Attenuation
OutputVoltage(into50KΩload) 7V 1:1000
Bandwidth(-3dB) 50MHz 100MHz Ratio
Offset <±5mV noise >60dBat1KHz;>50dBat1MHz DC:±3%(DCto10KV)
Impedance 50Ω AttenuationRatio 1000:1 Accuracy AC:±3%(1KHz/1KV/1KHzRMS)
-3dB:0~40MHz
CMRR -80dB@60Hz,-50dB@100KHz Accuracy DC:≤3%;AC:≤3%(1KHz)
Impedance 900MΩ 200MΩ Impedance 100MΩ±5%
14KV@1/1000 7000V@1/1000 1500V@1/1000
InputDifferentialVp-p InputCapacitor 2PF 1.5PF InputCapacitor 3.0PF±0.5PF
1.4KV@1/100 700V@1/100 150V@1/100
CableLength 2m±0.2m CableLength 2m±0.2m
PowerRequirements(Options) 6VDC/300mAmainsadaptor
Temperature Temperature
LengthofBNCCable 90cm ≤200PPM/℃ ≤200PPM/℃
Coefficien Coefficien
LengthofInputLeads 60cm
OperationTemp -10~55℃ OperationTemp 0~+50℃
DeviceWeight 500g Dimension 80(W)x80(H)x320(L)mm Dimension 340 x80Φ (cylindrical)
Dimension 186x84x38mm 165x69x26mm DeviceWeight 460g DeviceWeight 250g
CurrentProbe
TestRange 1mA - 400A Range AC 4A AC 40A AC 200A AC 200A - 400A TestRange 400mA - 4A Range DCA 400mA DCA 4A
AC
Resolution 1mA Accuracy ±2.0%rdg±5d ±3.0%rdg±5d Resolution 0.1mA DCCurrent Accuracy ±1.5%rdg±5d
Current
Bandwidth DC~200KHz(±3dB) Sensitivity 1mV/10mA 1mV/0.1A 1mV/1A Bandwidth DC~1MHz(±3dB) Sensitivity 1mV/1mA 1mV/10mA
JawSize 23mm (max) Range DC 4A DC 40A DC 200A DC 200-400A JawSize 5mm (max) Range ACA 400mA ACA 4A
DC
AutoZeroatPower-on √ Accuracy ±1.5%rdg±5d ±3.0%rdg±5d AutoZeroatPower-on √ ACCurrent Accuracy ±2.0%rdg±5d
Current
PowerSupply 9V 6F22 Batter y Sensitivity 1mV/10mA 1mV/0.1A 1mV/1A PowerSupply 9V 6F22 Batter y Sensitivity 1mV/1mA 1mV/10mA
42 43
CurrentProbe OscilloscopeProbe
Probe
Voltage 1V Peak
OscilloscopeProbe
1X: 85pF -115pF 1X: 85pF -115pF 1X: <300V Max Input 1X: <200V
Input C Max Input Voltage
10X: 14.5pF -17.5pF 10X: 14.5pF -17.5pF 10X: <600V Voltage 10X: <600V
Model TH3100A
Attenuation Ratio 100X
44 45