MUT2200EL | MC406
ELECTROMAGNETIC FLOWMETER
FEATURES
Hastelloy C electrodes as standard
Hastelloy B (optional)
Flanges: Titanium (optional)
Carbon steel (S235JR - 1.0037) Tantalum (optional)
AISI 304 (optional) Platinum (optional)
AISI 316 (optional)
Highly resistant acrylic paint
C4 paint (optional)
AISI 304 tube
AISI 316 (optional)
Integrated
pressure
port
PTFE or EBONITE liner
Fully welded and potted
construction
Certified IP68 protection Empty pipe electrode (inside)
MUT2200EL | MC406
ELECTROMAGNETIC FLOWMETER
FEATURES Reliable and robust techno polymer case
LCD display
Live flowrate
Battery power
Bidirectional Flow reading
Advanced self-diagnostic
Excellent data security
Module of temperature (optional)
Module of pressure (optional)
GSM/GPRS Euromag (optional)
MID OIML R49 certified
Compact or separate
MC406 separate (remote)
MC406 Horizontal
MC406 with GSM MC406 with GSM
MUT2200EL | MC406
ELECTROMAGNETIC FLOWMETER
SPECIFICATIONS
Pipe sizes - millimeters (mm) 15 up to 2000
Pipe sizes - inches (") 1/2" 3/4" 1" 1.1/4" 1.1/2" 2" 2.1/2" 3" 4" 5" 6" 8" 10" 12" 14" 16"
Flanges EN1092-1 PN16 to PN 40 / ANSI 150, 300, 600, 900
Flanges material Carbon steel (std), AISI304, AISI316
Electrodes Hastelloy C (std), Hastelloy B, Titanium, Tantalum, Platinum
Pressure Max 16 bar
Temperature EBONITE/HARD RUBBER -40/+80°C | PTFE -40/+130°C
Accuracy 0,2% +/-2mm/s
Tube Material AISI 304 (std) | AISI316
Liner reference standard WRAS FDA DM174 DPR777/82 DM21/09/773
Sensor Protection Degree IP68
Repeatability 0,1%
Reference standard 2014/35/EU - 2014/30/EU - OIML R49-1:2013 - 2014/32/EU MID - UNI EN ISO 15609-1/ES ISO 15614-1
Connection Compact or separate with cable lenght 30mt (battery powered) *100mt when mains powered
Digital filters Damping - cut-off (0,05 m/s default) - bypass - peak cut
Display and keys LCD display - Index, menu, and symbols icons for dedicated information
4 Push buttons to access all functions
Totalizer informations can be displayed with 5 decimal digits
Conformity 2014/35/EU - EN 61010-1:2013 (LVD) - 2014/30/EU - EN 61326-1:2013 (EMC)
Flow Units m, m3, l, ML, ft3, GAL
Outputs 2 pulses passive outputs (MOS), individual galvanically isolated - clean contact
Maximum load +/- 35V DC, 100 mA short circuit protected. 4...20mA loop powered optional
Communication Integrated Euromag IrComm interface
Datalogging 100,000 lines of data with a frequency of log between 1 minute and 120 minutes (default 15 minutes)
Transmitter type Battery powered - 2 x D Cell 3,6 V * - 12/24Vdc optional
Battery life Lithium battery pack up to 10 years
Add on modules GSM/GPRS Euromag Module
Pressure (1) and temperature (2)
Energy metering ready
Custody transfer Type approved OIML R49-1 2013 / EN 14154 MID EN-ISO 4064 - Certificate n. T10713
Totalizers 5 (2 positive, 2 negative and 1 net)
Date and time Yes
Data protection Password available, automatic firmware check and recover during the update
Alarms and status Status icon displayed and alarm logged in the datalogger
Self diagnostic Alarms available:
• excitation failure • empty pipe on the 4th electrode
• high temperature • high voltage supply
• pulse overlapped • wet electronic board
• empty pipe on the measuring electrodes
External verification Field verificator available for calibration verification and electronic status
Software for Commissioning (equal settings of meters) - Data print for documentation - Data export
communication and (CSV file) - Firmware update - Read instant flowrate - Read and write all non volatile
programming parameters - Download internal datalogger - View instrument event logger
MUT2200EL | MC406
ELECTROMAGNETIC FLOWMETER
Calibration and maximum error
MUT2200EL sensors belong to the reference Group B1 (ISO 11631). Each sensor is calibrated on an hydraulic bench
equipped with a reference weighting system and SIT certified. The uncertainty of the calibration is equal to 0.2%
+/- 2 mm/s. The repeatability is in the order of 0.1%.
Maximum Permissible Error is within the limits indicated in the following graph:
Flow rates chart
Flow rate [m3/h] Ratio Flow rate [m3/h] Ratio
Sensor Sensor
Min. Trans. Perm. Overl. Q3/ Min. Trans. Perm. Overl. Q3/
diameter Q0,5% diameter Q0,5%
Q1 Q2 Q3 Q4 Q1 Q1 Q2 Q3 Q4 Q1
DN25 - 1” 0,080 0,128 1,40 10,00 12,50 125 DN450 - 18” 25 40 460 2.500 3.125 100
DN32 - 1 1/4” 0,080 0,128 2,30 10,00 12,50 125 DN500 - 20” 25 40 570 2.500 3.125 100
DN40 - 1 1/2” 0,128 0,205 3,60 16,00 20,00 125 DN600 - 24” 50 80 820 4.000 5.000 80
DN 50 - 2” 0,200 0,320 5,65 25,00 31,25 125 DN700 - 28” 50 80 1.100 4.000 5.000 80
DN 65 - 2 1/2” 0,320 0,512 9,55 40,00 50,00 125 DN800 - 32” 100 160 1.450 6.300 7.875 63
DN 80 - 3” 0,504 0,806 14,50 63,00 78,75 125 DN900 - 36” 100 160 1.840 6.300 7.875 63
DN 100 - 4” 0,800 1,280 22,60 100,00 125,00 125 DN1000 - 40” 200 320 2.270 10.000 12.500 50
DN 125 - 5” 1,280 2,048 35,30 160,00 200,00 125 DN1200 - 48” 320 512 3.270 16.000 20.000 50
DN 150 - 6” 2,000 3,200 51,00 250,00 312,50 125 DN1400 - 56” 500 800 4.440 25.000 31.250 50
DN 200 - 8” 3,200 5,120 90,50 400,00 500,00 125 DN1500 - 60” 800 1.280 5.100 40.000 50.000 50
DN 250 - 10” 5,040 8,064 140,00 630,00 787,50 125 DN1600 - 64” 1.260 2.016 5.800 63.000 78.750 50
DN 300 - 12” 8,000 12,800 200,00 1.000,00 1.250,00 125 DN1800 - 72” 2.000 3.200 7.350 100.000 125.000 50
DN 350 - 14” 12,800 20,480 280,00 1.600,00 2.000,00 125 DN2000 - 80” 3.200 5.120 9.100 160.000 200.000 50
DN 400 - 16” 12,800 20,480 360,00 1.600,00 2.000,00 125