Order Online Today!: Series RHP
Order Online Today!: Series RHP
                                     3-45/64                      55/64
                                     [94.06]                     [21.83]                                                                                           2-9/16
                                                                                                                                                                  [64.96]
                                                                                                                                                                                                                 SERIES RHP | HUMIDITY/TEMPERATURE TRANSMITTERS
                                         6-25/32                                                   2-11/64                                                        2-11/64
                                         [172.16]                                                  [55.17]                                                        [55.12]
                                                                                                                 1/2 NPT
                                                                                                             2-41/64
                         2-41/64                                                                              [67.03]                    8-61/64
                         [67.07]                                                                             2-9/64                      [227.30]
                                                                                                             [54.37]
                  OSA (outside air) with sintered filter                                                                      35/64
                                                                                                                             [13.89]
                                                                      5-1/8                        3-11/64
       4-17/32                     2-15/64                  4-17/32 [130.18]                       [80.57]                                                            A-RHP-FC
       [115.09]                    [56.75]                  [115.09]
                 Ø3/16
                                                                           6-25/32
                                                                           [172.09]
                                                                                                                                                                                                                 FEATURES/BENEFITS
                  [4.76]
               MOUNTING                                                                                                                                                                                          •	   2%, 3%, or 5% accuracy models to meet project requirements
                 HOLES
               TYP 4 PLCS                                                                                                                                                                                        •	   Integral temperature sensors reduces number of devices to install
                                       55/64
                                      [21.83]                                                                                                                                                                    •	   Radiation shield option protects sensor from radiant heating effects allowing for accurate readings even when mounted in
                              OSA (outside air)                                                                                                                                                                  	    direct sunlight
HOW TO ORDER                                                                                                                                                                                                     APPLICATIONS                                                                         DESCRIPTION
Use the bold characters from the chart below to construct a product code.                                                                                                                                        •	 Air economizers                                                                   The Series RHP Humidity/Temperature Transmitters combine the
                                                                    RHP               -2       D             1           A             -LCD                                                                      •	 Outdoor temperature and relative humidity reference for building systems          voltage or current humidity transmitter output with a passive temperature
                                                                                                                                                                                                                                                                                                      thermistor or RTD output. The polymer capacitance humidity sensor
                                                                                                                                                                                                                                                                                                      reduces longterm affect of condensation, fog, or high humidity. The
SERIES                                                                                                                                        OPTIONS                                                                                                                                                 humidity sensors are available with 2%, 3% or 5% accuracies. Duct
RHP: RH/passive temperature sensor transmitter                                                                                                -LCD: LCD display                                                                                                                                       mounted transmitters are available with an optional two-line alpha
                                                                                                                                              -NIST: NIST traceable calibration certificate                                                                                                           numeric LCD display.
ACCURACY                                                                                                                                                                                                         SPECIFICATIONS
-2: 2% accuracy                                                                                                                               TEMPERATURE SENSOR                                                        Relative Humidity Range      0 to 100% RH.
-3: 3% accuracy                                                                                                                               0: None                                                                        Temperature Range       -40 to 140°F (-40 to 60°C).
-5: 5% accuracy                                                                                                                               1: 4-20 mA
                                                                                                                                                                                                                                    Accuracy, RH     RHP-2XXX ±2% 10-90% RH @ 25°C; RHP-3XXX ±3% 20-80% RH @ 25°C; RHP-5XXX ±5% 20-80% RH @ 25°C.
                                                                                                                                              2: 0-10 VDC
                                                                                                                                                                                                                     Accuracy, Thermistor Temp       ±0.2°C @ 25°C (±0.36°F @ 77°F).
HOUSING TYPE                                                                                                                                  3: 0-5 VDC
                                                                                                                                                                                                                                          Sensor
D: Duct mount with plastic hydrophobic filter                                                                                                 A: 10K @ 25°C thermistor type III
O: OSA (outside air)                                                                                                                          B: 10K @ 25°C thermistor type II                                      Accuracy, RTD Temp Sensor        DIN Class B; ±0.3°C @ 0°C (±0.54°F @ 32°F).
S: OSA with sintered filter*                                                                                                                  C: 3K @ 25°C thermistor                                                 Accuracy, Solid State Band     ±0.9°F @ 77°F (±0.3°C @ 25°C).
R: Radiation shield                                                                                                                           D: 100 Ω RTD DIN 385                                                                           Gap
                                                                                                                                              E: 1K Ω RTD DIN 385                                                                     Hysteresis     ±1%.
*Use OSA with sintered filter models when purchasing                                                                                          F: 20K Ω @ 25°C thermistor                                                            Repeatability    ±0.1% typical.
Series RHRS separately.                                                                                                                                                                                                      Temperature Limits      -40 to 140°F (-40 to 60°C).
                                                                                                                                              RH OUTPUT
                                                                                                                                                                                                                           Storage Temperature       -40 to 176°F (-40 to 80°C).
                                                                                                                                              1: 4-20 mA
                                                                                                                                              2: 0-10 V                                                               Compensated Temperature        -4 to 140°F (-20 to 60°C).
                                                                                                                                              3: 0-5 VDC                                                                                   Range
ACCESSORIES
                                                                                                                                                                                                                  4-20 mA Loop Powered Models        Power requirements: 10-35 VDC; Output signal: 4-20 mA.
 Model              Description                                                                                                                                                                                          0-5/10 V Output Models      Power requirements: 15-35 VDC or 15-29 VAC; Output signal: 0-10 V @ 5 mA max.
 A-RHP-FC           Replacement plastic hydrophobic filter                                                                                                                                                                        Response Time      15 s.
 A-RHP-RT           Retrofit tool for fitting O-ring on RHP-D/M models for new filter A-RHP-FC                                                                                                                            Electrical Connections     Removable screw terminal block.
                                                                                                                                                                                                                             Conduit Connection      Duct mount: 1/2˝ NPS; OSA: PG11 or PG16 (1/2˝ conduit) knockouts.
ORDER ONLINE TODAY!                                                                                                                                                                                                                          Drift
                                                                                                                                                                                                                                      RH Sensor
                                                                                                                                                                                                                                                     < 1% RH/year.
                                                                                                                                                                                                                                                     Capacitance polymer.
dwyer-inst.com/Product/SeriesRHP                                                                                                                                                                                            Temperature Sensor       Types 1, 2, 3: Solid state band gap; Curves A, B, C: Thermistor; Curves D, E: Platinum RTD DIN 385.
                                                                                                                                                                                                                                       Enclosure     Duct mount: PBT; OSA: Polycarbonate.
                                                                                                                                                    DWYER INSTRUMENTS, INC.                                                    Enclosure Rating      Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66).
                                                                                                                                                                                                                                         Display     Duct mount only, optional 2-line alpha numeric, 8 characters/line.
©Copyright 2020 Dwyer Instruments, Inc.
Printed in U.S.A. 4/20					                                                                                                                                                                 DS-RHP Rev. 4                     Display Resolution     RH: 0.1%; 0.1°F (0.1°C).
                                                                                                                                                                                                                                          Weight     Duct mount: .616 lb (.3 kg); OSA: 1 lb (.45 kg).
Important Notice: Dwyer Instruments, Inc. reserves the right to make changes to or discontinue any product or service identified in this publication without notice. Dwyer advises its customers to obtain the
latest version of the relevant information to verify, before placing any orders, that the information being relied upon is current.
                                                                                                                                                                                                                              Agency Approvals       CE.
DIMENSIONS
                     5-1/8                                                                                                                                                    [3] 3/16 [4.76] HOLES
                   [130.18]                             2-1/4                                                                                                                  EQUALLY SPACED                                                 ®
                                                       [57.15]                                                                                                               ON A 4.115 [104.52] BC
                                     3-45/64                      55/64
                                     [94.06]                     [21.83]                                                                                           2-9/16
                                                                                                                                                                  [64.96]
                                                                                                                                                                                                                 SERIES RHP | HUMIDITY/TEMPERATURE TRANSMITTERS
                                         6-25/32                                                   2-11/64                                                        2-11/64
                                         [172.16]                                                  [55.17]                                                        [55.12]
                                                                                                                 1/2 NPT
                                                                                                             2-41/64
                         2-41/64                                                                              [67.03]                    8-61/64
                         [67.07]                                                                             2-9/64                      [227.30]
                                                                                                             [54.37]
                  OSA (outside air) with sintered filter                                                                      35/64
                                                                                                                             [13.89]
                                                                      5-1/8                        3-11/64
       4-17/32                     2-15/64                  4-17/32 [130.18]                       [80.57]                                                            A-RHP-FC
       [115.09]                    [56.75]                  [115.09]
                 Ø3/16
                                                                           6-25/32
                                                                           [172.09]
                                                                                                                                                                                                                 FEATURES/BENEFITS
                  [4.76]
               MOUNTING                                                                                                                                                                                          •	   2%, 3%, or 5% accuracy models to meet project requirements
                 HOLES
               TYP 4 PLCS                                                                                                                                                                                        •	   Integral temperature sensors reduces number of devices to install
                                       55/64
                                      [21.83]                                                                                                                                                                    •	   Radiation shield option protects sensor from radiant heating effects allowing for accurate readings even when mounted in
                              OSA (outside air)                                                                                                                                                                  	    direct sunlight
HOW TO ORDER                                                                                                                                                                                                     APPLICATIONS                                                                         DESCRIPTION
Use the bold characters from the chart below to construct a product code.                                                                                                                                        •	 Air economizers                                                                   The Series RHP Humidity/Temperature Transmitters combine the
                                                                    RHP               -2       D             1           A             -LCD                                                                      •	 Outdoor temperature and relative humidity reference for building systems          voltage or current humidity transmitter output with a passive temperature
                                                                                                                                                                                                                                                                                                      thermistor or RTD output. The polymer capacitance humidity sensor
                                                                                                                                                                                                                                                                                                      reduces longterm affect of condensation, fog, or high humidity. The
SERIES                                                                                                                                        OPTIONS                                                                                                                                                 humidity sensors are available with 2%, 3% or 5% accuracies. Duct
RHP: RH/passive temperature sensor transmitter                                                                                                -LCD: LCD display                                                                                                                                       mounted transmitters are available with an optional two-line alpha
                                                                                                                                              -NIST: NIST traceable calibration certificate                                                                                                           numeric LCD display.
ACCURACY                                                                                                                                                                                                         SPECIFICATIONS
-2: 2% accuracy                                                                                                                               TEMPERATURE SENSOR                                                        Relative Humidity Range      0 to 100% RH.
-3: 3% accuracy                                                                                                                               0: None                                                                        Temperature Range       -40 to 140°F (-40 to 60°C).
-5: 5% accuracy                                                                                                                               1: 4-20 mA
                                                                                                                                                                                                                                    Accuracy, RH     RHP-2XXX ±2% 10-90% RH @ 25°C; RHP-3XXX ±3% 20-80% RH @ 25°C; RHP-5XXX ±5% 20-80% RH @ 25°C.
                                                                                                                                              2: 0-10 VDC
                                                                                                                                                                                                                     Accuracy, Thermistor Temp       ±0.2°C @ 25°C (±0.36°F @ 77°F).
HOUSING TYPE                                                                                                                                  3: 0-5 VDC
                                                                                                                                                                                                                                          Sensor
D: Duct mount with plastic hydrophobic filter                                                                                                 A: 10K @ 25°C thermistor type III
O: OSA (outside air)                                                                                                                          B: 10K @ 25°C thermistor type II                                      Accuracy, RTD Temp Sensor        DIN Class B; ±0.3°C @ 0°C (±0.54°F @ 32°F).
S: OSA with sintered filter*                                                                                                                  C: 3K @ 25°C thermistor                                                 Accuracy, Solid State Band     ±0.9°F @ 77°F (±0.3°C @ 25°C).
R: Radiation shield                                                                                                                           D: 100 Ω RTD DIN 385                                                                           Gap
                                                                                                                                              E: 1K Ω RTD DIN 385                                                                     Hysteresis     ±1%.
*Use OSA with sintered filter models when purchasing                                                                                          F: 20K Ω @ 25°C thermistor                                                            Repeatability    ±0.1% typical.
Series RHRS separately.                                                                                                                                                                                                      Temperature Limits      -40 to 140°F (-40 to 60°C).
                                                                                                                                              RH OUTPUT
                                                                                                                                                                                                                           Storage Temperature       -40 to 176°F (-40 to 80°C).
                                                                                                                                              1: 4-20 mA
                                                                                                                                              2: 0-10 V                                                               Compensated Temperature        -4 to 140°F (-20 to 60°C).
                                                                                                                                              3: 0-5 VDC                                                                                   Range
ACCESSORIES
                                                                                                                                                                                                                  4-20 mA Loop Powered Models        Power requirements: 10-35 VDC; Output signal: 4-20 mA.
 Model              Description                                                                                                                                                                                          0-5/10 V Output Models      Power requirements: 15-35 VDC or 15-29 VAC; Output signal: 0-10 V @ 5 mA max.
 A-RHP-FC           Replacement plastic hydrophobic filter                                                                                                                                                                        Response Time      15 s.
 A-RHP-RT           Retrofit tool for fitting O-ring on RHP-D/M models for new filter A-RHP-FC                                                                                                                            Electrical Connections     Removable screw terminal block.
                                                                                                                                                                                                                             Conduit Connection      Duct mount: 1/2˝ NPS; OSA: PG11 or PG16 (1/2˝ conduit) knockouts.
ORDER ONLINE TODAY!                                                                                                                                                                                                                          Drift
                                                                                                                                                                                                                                      RH Sensor
                                                                                                                                                                                                                                                     < 1% RH/year.
                                                                                                                                                                                                                                                     Capacitance polymer.
dwyer-inst.com/Product/SeriesRHP                                                                                                                                                                                            Temperature Sensor       Types 1, 2, 3: Solid state band gap; Curves A, B, C: Thermistor; Curves D, E: Platinum RTD DIN 385.
                                                                                                                                                                                                                                       Enclosure     Duct mount: PBT; OSA: Polycarbonate.
                                                                                                                                                    DWYER INSTRUMENTS, INC.                                                    Enclosure Rating      Duct mount: NEMA 4X (IP66) for housing only; OSA: NEMA 4X (IP66).
                                                                                                                                                                                                                                         Display     Duct mount only, optional 2-line alpha numeric, 8 characters/line.
©Copyright 2020 Dwyer Instruments, Inc.
Printed in U.S.A. 4/20					                                                                                                                                                                 DS-RHP Rev. 4                     Display Resolution     RH: 0.1%; 0.1°F (0.1°C).
                                                                                                                                                                                                                                          Weight     Duct mount: .616 lb (.3 kg); OSA: 1 lb (.45 kg).
Important Notice: Dwyer Instruments, Inc. reserves the right to make changes to or discontinue any product or service identified in this publication without notice. Dwyer advises its customers to obtain the
latest version of the relevant information to verify, before placing any orders, that the information being relied upon is current.
                                                                                                                                                                                                                              Agency Approvals       CE.