0% found this document useful (0 votes)
129 views8 pages

Industrial Valve Specifications

This document provides information on directional control valves including: - Details on 3/2, 5/2, and 5/3 directional control valves with electromagnetic actuation and indirect control of soft seal spool valves. - Safety functions in the event of power failure through a mechanical return spring. - Reversible seals allow for 3/2 or 5/2 way functions. - Compact design with simple soft seal spool system and easily interchangeable solenoids. - Technical specifications including flow rates, pressure ranges, materials, and electrical connection options.

Uploaded by

Stefaan Jacobs
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
129 views8 pages

Industrial Valve Specifications

This document provides information on directional control valves including: - Details on 3/2, 5/2, and 5/3 directional control valves with electromagnetic actuation and indirect control of soft seal spool valves. - Safety functions in the event of power failure through a mechanical return spring. - Reversible seals allow for 3/2 or 5/2 way functions. - Compact design with simple soft seal spool system and easily interchangeable solenoids. - Technical specifications including flow rates, pressure ranges, materials, and electrical connection options.

Uploaded by

Stefaan Jacobs
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

97100

3/2-, 5/2- and 5/3 Directional Control


Actuation: Electromagnetic
Indirectly controlled soft seal spool valves
Connection G 1/4, 1/4 NPT
NAMUR Interface
● For single and double operated actuators

● Exhaust air recirculation (3 way function)

● Crossover-free switching, switch-over function


guaranteed even with small cross section air supply

● Safety function in the event of power failure provided


by mechanical return spring (monostable design)

● Reversible seal allows 3/2 or 5/2 way function

● Manual override with detent

● Compact design

● Simple design of soft seal spool system

● Easily interchangeable solenoid

Technical data Ordering example


Medium: 5/2 directional control valve, port size G 1/4,
Filtered, non-lubricated and dry compressed air solenoid 24 V DC, with connector DIN 43650
Actuation: form B, Protection class IP 65
Solenoid operated, indirectly controlled Type: 9710000.3051.024.00
Flow direction:
Fixed Connectors
Mounting position:
See data sheet 7503364
Optional
Nominal diameter:
6 mm
Port size: 3/2 5/2
1: G 1/4, 1/4 NPT, 3+5: G 1/8, 1/8-NPT 42 42
Electrical connection:
Connector interface to DIN 43650 form A and B
Operating pressure: 513 513
Max. 8 bar
Temperatures:
Valve: -25* to +50 °C 5/3
Solenoid: See solenoid table 4 2
* With minus temperatures, use conditioned dry air. If installed in the open
protect all connections against the penetration of moisture!
Material:
513
Housing: Aluminium anodized
Pilot flange: Plastic (PBT)
Seals: NBR (Perbunan)

03/01 Our policy is one of continued research and development. We therefore reserve the right
to amend, without notice, the specifications given in this document.
N/** 5.4.151.01
97100

General information
Valves, standard design
Symbol Type * Port size Actuation Operating pressure (bar) Flow Weight Dimensional
1, 3 ( 5) 2 (4) Min. Max. (l/min) (kg) drawing
42 9710000 G 1/4 Flange Solenoid/Spring 2 8 750 0,25 M01
14 12

513 9710010 1/4 NPT Flange 2 8 750 0,25 M01

42 9711000 G 1/4 Flange Solenoid/Solenoid 2 8 750 0,35 M02


14 12

513 9711010 1/4 NPT Flange 2 8 750 0,35 M02

14
4 2 12
9712000 G 1/4 Flange Solenoid/Solenoid 2 8 500 0,40 M03
mid position NC
513
9712010 1/4 NPT Flange 2 8 500 0,40 M03

* When ordering, please indicate solenoid, voltage and current type (frequency).

Solenoid actuators
Type Current draw Protection class Temperature Weight Dimensional Circuit diagram
24 V DC 230 V AC Fluid max. Ambience drawing
(W) (VA) (°C) (°C) (kg)

3050 1,7 5,6/4,3 IP 00 w/o connector +50 -15 to +50 0,06 M04 SB01

3051 1,7 5,6/4,3 IP 65 with connector +50 -15 to +50 0,08 M04 SB01
DIN 43650 Form B

3036 1,6 4,55/3,5 IP 00 w/o connector +50 -15 to +50 0,09 M05 SB01

3037 1,6 4,55/3,5 IP 65 with connector +50 -15 to +50 0,12 M05 SB01
DIN 43650 Form A

3042 3,3 – EEx m II T5 +80 -15 to +50 0,13 M06 SB01


with cable 3 m

3043 – 3,3 EEx m II T5 +80 -15 to +50 0,13 M06 SB08


with cable 3 m

Standard voltages 24 V DC, 230 V AC. Other voltages on request.

Our policy is one of continued research and development. We therefore reserve the right
N/** 5.4.151.02 to amend, without notice, the specifications given in this document. 03/01
97100

General information
Valves for minimal electrical power, inkl. EEx i 1)
Symbol Type * Port size Actuation Operating pressure (bar) Flow Weight Dimensional
1, 3 ( 5) 2 (4) Min. Max. (l/min) (kg) drawing
42 9710002 G 1/4 Flange Solenoid/Spring 2 8 750 0,25 M01
14 12

513 9710012 1/4 NPT Flange 2 8 750 0,25 M01

42 9711002 G 1/4 Flange Solenoid/Solenoid 2 8 750 0,35 M02


14 12

513 9711012 1/4 NPT Flange 2 8 750 0,35 M02

14
4 2 12
9712002 G 1/4 Flange Solenoid/Solenoid 2 8 500 0,40 M03
mid position NC
513
9712012 1/4 NPT Flange 2 8 500 0,40 M03

* When ordering please indicate solenoid, voltage and current type (frequency).
Outside free of nonferrous metals

Solenoid actuators
Type Current draw Rated current at Protection class Temperature Weight Dimensional Circuit
24V DC 230V AC 24V DC 230V AC Fluid max. Ambience drawing diagram
(W) (VA) (mA) (mA) (°C) (°C) (kg)

3034 0,7 - 30 - IP 00 w/o connector +80 -15 to +50 0,1 M05 SB01

3035 0,7 - 30 - IP 65 with connector +80 -15 to +50 0,1 M05 SB01
DIN 43650 Form A by DC

3044* 0,9 - 30 - EEx m II T6 +80 -15 to +50 0,4 M06 SB01


with cable 3 m

3045* - 0,9 - 5 EEx m II T6 +80 -15 to +50 0,4 M06 SB08


with cable 3 m

Standard voltages 24V DC, 230V AC. Other voltages on request.


Design acc. to VDE 0580, EN 50014/50028. 100% duty cycle.

For intrinsically safe circuits, protection class EEx ia IIC T6


Type Nom. resistance Required Resistance Required voltage Ambient Fluid temperature Weight Dimensional Circuit
RN coil switching current Rw 50 coil at terminal temperature max. (kg) drawing diagram
(Ω) (mA) Rw 50 (°C) (°C)

3039** 275 37 330 12 -15 to +50 +80 0,83 M05 SB13

When selecting an intrinsically safe power supply, the permissible maximum values according to the Certificate of Conformity should be taken in
account. On the other hand, the low effective inductivity and capacity can be ignored.

* Certificate of Conformity PTB No. Ex-95.C.2153 X


** Certificate of Conformity PTB No. Ex-95.C.2152, CSA-Certificate No. LR 51090-4, FM approved.
Required connector acc. to DIN 43650 or ISO 4400. Installation acc. to requirements of FM and CSA.
1) Valves can only be operated with DC solenoids; required connector for DC: type 0570275, connector with rectifier for AC or universal current:

Type 0663303

Our policy is one of continued research and development. We therefore reserve the right
03/01 to amend, without notice, the specifications given in this document. N/** 5.4.151.03
97100

General dimensions valves


M01 M02
5.5 5.5
19.5 19.5
M5 M5
13 13

2 4 2 4

7.2
3

7.2

37.2
37.2

25
25

1
0
0
1
0
1

20.5 18 18
38.5 93.2
56.5 186.3
131.7
24
24
12 12 78.8
24.4

32
40
32
40

3 1 5 3 1 5
G 1/4 G 1/8 G 1/4 G 1/8

M03

5.5
19.5
M5
13
2 4
3

7.2
37.2
25
1
0
0
1

18 18
109.8
203

24
12 95.6
32
40

3 1 5
G 1/4 G 1/8

Our policy is one of continued research and development. We therefore reserve the right
N/** 5.4.151.04 to amend, without notice, the specifications given in this document. 03/01
97100

General dimensions solenoids


M04 M05

29 36

29,5
29,5

11 15
65 12 72 12

30
22

Ø9 Ø9

M06

36
29,5

15
68
30

Ø9

Circuit diagrams

SB01 SB04 SB07

SB08 SB13

Our policy is one of continued research and development. We therefore reserve the right
03/01 to amend, without notice, the specifications given in this document. N/** 5.4.151.05
97100

NAMUR interface
32

M5 thread 8 mm deep

24
Coding stud threaded
M5x10 DIN 913-45 H
12
8

M5
2

G 1/ 4
DIN/ISO 228/1

Fitting accessories
Description Type Use Weight See
(kg) publication
Flange plate 0559857 Direct attachment to pneumatic linear actuators with NAMUR ridge; in the case of wall mounting, 0,50 7502242
dependent on position of piping
Clamp 0540593 Used in conjunction with flange plate for attachment to pneumatic linear actuators with NAMUR post 0,1
Adaptor plate 0559853 Direct attachment to pneumatic rotary actuators with interface corresponding to former type valves 0,18
Silencer 0014600 Pressure connection G 1/4. Max. back pressure 6 bar 0,01 7501080

Warning
These products are intended for use in industrial compressed air systems only. Do not all component parts used in fluid power systems and to provide adequate safeguards
use these products where pressures and temperatures can exceed those listed under to prevent personal injury or damage to equipment in the event of such failure.
‘Technical Data’. System designers must provide a warning to end users in the system
Before using these products with fluids other than those specified, for non-industrial instructional manual if protection against a failure mode cannot be adequately
applications, life-support systems, or other applications not within published provided.
specifications, consult NORGREN. System designers and end users are cautioned to review specific warnings found in
Through misuse, age, or malfunction, components used in fluid power systems can instruction sheets packed and shipped with these products where applicable.
fail in various modes. The system designer is warned to consider the failure modes of

Our policy is one of continued research and development. We therefore reserve the right
N/** 5.4.151.06 to amend, without notice, the specifications given in this document. 03/01
97100

Our policy is one of continued research and development. We therefore reserve the right
03/01 to amend, without notice, the specifications given in this document. N/** 5.4.151.07
97100

Our policy is one of continued research and development. We therefore reserve the right
N/** 5.4.151.08 to amend, without notice, the specifications given in this document. 03/01