Ipstring Command: (Described in Ipkeyword - Dat)

This document summarizes the parameters used in a user's manual converter for body part parameter files. It describes: 1) Parameters like body part, view position, irradiation field recognition that specify the image analysis method. 2) Options for cropping, quality assurance processing, grid line elimination, and high density clipping. 3) Indices for parameters mapped in the quality assurance and DWT processing graphical user interfaces. 4) Parameters for flipping, rotating, sharpening adjustment, and DWT processing. 5) Indices for parameters mapped in the DWT processing graphical user interface. 6) Options for Laplacian sharpening, dynamic range adjustment, and collimation mask processing. 7) Parameters for

Uploaded by

Javier Paredes
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
49 views4 pages

Ipstring Command: (Described in Ipkeyword - Dat)

This document summarizes the parameters used in a user's manual converter for body part parameter files. It describes: 1) Parameters like body part, view position, irradiation field recognition that specify the image analysis method. 2) Options for cropping, quality assurance processing, grid line elimination, and high density clipping. 3) Indices for parameters mapped in the quality assurance and DWT processing graphical user interfaces. 4) Parameters for flipping, rotating, sharpening adjustment, and DWT processing. 5) Indices for parameters mapped in the DWT processing graphical user interface. 6) Options for Laplacian sharpening, dynamic range adjustment, and collimation mask processing. 7) Parameters for

Uploaded by

Javier Paredes
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

User’s Manual/BodyPart parameter file converter

IPString command (described in IPKeyword.dat)


BPC=bodyPart,viewPos;
Type of body part
This code specifies the analysis method according to the body part.
for image
bodyPart Exposed body part/method code.
processing
viewPos Imaging direction code. 1/2 Front view/Side view.
CC=AUTO;
Irradiation field Enables or disables irradiation field recognition.
recognition control It is not specified when in full automatic (AUTO) mode or when disabled.
It should not be specified when PTR is described as below.
PTR=org.x,org.y,rectWidth,rectHeight;
Without performing irradiation field recognition, it specifies the fixed image
Fixed cropping
cropping position. In case of "FULL”, cropping will not be performed at all.
It should not be specified when CC is described as above.
QAP=dep,susm,tone;
dep 0/1 DEP processing ON/OFF
QA processing susm 0/1 sharpening processing ON/OFF
control
0/1 tone processing ON/OFF However, the current OPU
tone does not allow switching the tone processing ON/OFF, it
will always substitute 1.
Grid line SG=0/1;
elimination request 1: Grid line elimination will be performed.
High density C=0/1;
clipping request 1: High density clipping will be performed.
QID=X,Y,Z,eeFrqIdx,
eeERIdx ,drHPVIdx,drHCrIdx,drLPVIdx,drLCrIdx,drMaskSizeIdx ,toneCS,tnD
ensIdx,tnCntIdx;
Describes the index of the parameters for each process which is mapped on the
GUI during the QA process.
X,Y,Z: Version display (version of the parameter table)
The enhanced frequency index of the edge enhancing
eeFreqIdx
process (1-11)
The enhancement factor index of the edge enhancing
QA processing eeEDIdx
process (1-11)
parameter index
drHPVIdx Not used
DrHCrIdx Not used
DrLPVIdx Not used
DrLCrIdx Not used
Mask size index of the blurred image generation for DR
drMaskSizeIdx
compression (1-11)
TnCSIdx Gradation curve index for tone processing (1-5)
tnDensIdx Supported density index for tone processing (1-29)
TnCntIdx Contrast index for tone processing (1-29)
FLP=0/1/2;
Flipping process Performs the flipping process. In case of 1, horizontal flipping, in case of 2,
vertical flipping will be performed.

English Edition Rev.04 Mar. 2008 -1- All Rights Reserved.


(C)Canon Inc.
User’s Manual/BodyPart parameter file converter

ROT=0/1/2/3/4/5/6;
Performs the rotation process. Performs clockwise rotation by 90 degrees (1),
Rotation process
180 degrees (2), 270 degrees (3), -90 degrees (4), -180 degrees (5), -270 degrees
(6).
MTF2=Mode, Type, Intensity;
0: OFF
1: Fixed mode (MTF improvement process prior to V4.2)
Mode
2: Dose-dependent mode (dose-dependent sharpening
factor adjustment)
Filter type index (valid only when Mode=2)
Sharpening factor 1: Chest front
adjustment process 2: Abdomen
3: Head
Type
4: Cervical vertebra
5: Thoracic vertebra
6: Lumbar vertebra
7: Extremities
Intensity 1 - 3: Intensity index (valid only when Mode=2)
DWT=wDep,wSharp,wDenoise;
0/1/2/3 DEP process. In order, low density side, high
DWT process WDep
density side= OFF,OFF/ON,OFF/OFF,ON/ON,ON
control
WSharp 0/1 sharpening processing OFF/ON
wDenoise 0/1 noise elimination OFF/ON
WID=wDepHPVIdx,wDepHCrIdx,wDepHItIdx,wDepLPVIdx,wDepLCrIdx,w
DepLItIdx,wDepMTIdx,wSharpEDIdx,wSharpFTIdx,wSharpPTIdx,wSharpMT
Idx,wDenoiseItIdx,wDenoiseWdIdx,wDenoiseMTIdx;
Describes the index of the parameters for each process which is mapped on the
GUI during the DWT process.
DEP processing. High density side compression starting
wDepHPVIdx
point index (0-30)
DEP processing.
wDepHCrIdx
High density side change factor index (0-20)
DEP processing.
wDepHItIdx
High density side intensity index (0-10)
DWT process DEP processing.
wDepLPVIdx
parameter index Low density side compression starting point index (0-30)
DEP processing.
wDepLCrIdx
Low density side change factor index (0-20)
DEP processing.
wDepLItIdx
Low density side intensity index (0-10)
wDepMTIdx Fixed to 0
Sharpening process.
wSharpEDIdx
Enhancement index (1-20)
Sharpening process.
wSharpFTIdx
Enhancement type index (1-20)
Sharpening process.
wSharpPTIdx
Density-dependent processing type index (1-20)

English Edition Rev.04 Mar. 2008 -2- All Rights Reserved.


(C)Canon Inc.
User’s Manual/BodyPart parameter file converter

wSharpMTIdx Fixed to 0
Noise elimination.
wDenoiseItIdx
DWT process Intensity index (1-10)
parameter index Noise elimination.
WDenoiseWdIdx
Processing range index (0-30)
WDenoiseMTIdx Fixed to 0
LPS=doLPS,lpsIntensityIdx,lpsFreqTypeIdx;(Maximum 12bytes)
Switches the Laplacian sharpening ON/OFF and specifies the processing
MLT(M)
parameters.
Laplacian
DoLPS 0/1 Laplacian sharpening processing OFF/ON
sharpening
The enhancement factor index of the Laplacian sharpening
process lpsIntensityIdx
process (1-20)
lpsFreqTypeIdx Fixed to 0
RC=doRC,rcWidthIdx; (Maximum 10 bytes)
Switches the dynamic range adjustment ON/OFF and specifies the pixel value
MLT(M)
range.
Dynamic range
doRC Fixed to 0
adjustment process
Dynamic range adjustment process pixel value range index
rcWidthIdx
(1-20)
Hidden function LPD
Collimation mask PM=0/1
process 1: Collimation mask processing will be performed.
SPE=doSPE,effectIdx,freqIdx,methodIdx;
Switches the MLT(S) edge enhancement ON/OFF and specifies the processing
MLT(S) parameters.
Edge enhancement doSPE 0/1 Edge enhancement processing OFF/ON
process effectIdx Enhancement effect (1-20)
freqIdx Enhancement freq. Band (0-20)
methodIdx Fixed to 1
SPD=doSPD,upperIdx,lowerIdx,freqIdx,methodIdx;
Switches the MLT(S) dynamic range adjustment process ON/OFF and specifies
the processing parameters.
doSPD 0/1/2/3
MLT(S) Dynamic range adjustment process on the dark region
Dynamic range and the bright region =
adjustment process OFF, OFF/OFF, ON/ON, OFF/ON, ON
upperIdx Maximum density (1-20)
lowerIdx Minimum density (1-20)
freqIdx Fixed to 1
methodIdx Fixed to 1
SPN=doSPN,effectIdx,procUpperIdx,methodIdx;
Switches the MLT(S) noise reduction process ON/OFF and specifies the
MLT(S) processing parameters.
Noise reduction doSPD 0/1 Noise reduction processing OFF/ON
process effectIdx Noise reduction effect (1-10)
procUpperIdx Fixed to 30
methodIdx Fixed to 1

English Edition Rev.04 Mar. 2008 -3- All Rights Reserved.


(C)Canon Inc.
User’s Manual/BodyPart parameter file converter

IPMiscString command (described in IPMiscKeyword.dat)


Image AM=A/R;
acquisition Specifies the image acquisition mode. A: AUTO, R:REX The OPU appends this
mode string and sends it to the CCR1. The default setting is AUTO. When REX value
(Acq. Mode) mode is set, the later described SR=xxx; will also be appended.
SR=400;
Specified
When AM=R, the OPU appends the REX value specified by the user to the string
REX value
and sends it to the CCR1. The default value was changed to 400 (from V40).
RQI=eeFrqIdx,
eeERIdx ,drHPVIdx,drHCrIdx,drLPVIdx,drLCrIdx,,tnPixIdx,tnCntIdx;
Relative index value changed on the QA screen. The legacy ± expression of Ver.2.0
was changed starting with Ver.3.X, to be used for setting and modifying the four
processing parameters (other than the DEP mask size) before and after imaging.
eeFreqIdx Not used
eeEDIdx Not used
Relative QA DR compression high density side compression starting
drHPVIdx
processing point index (-10 - 10). 0 included.
parameter index DR compression high density side compression factor
drHCrIdx
index (-10 - 10). 0 included.
DR compression low density side compression starting
drLPVIdx
point index (-10 - 10).
DR compression low density side compression factor index
drLCrIdx
(-10 - 10). 0 included.
tnPixIdx Not used
tnCntIdx Not used
QAM=qaProcMode; 9(Maximum 6 bytes)
Frequency Specifies the selected frequency processing mode.
processing 0: Standard frequency processing
mode qaProcMode 1: MLT(F) frequency processing
2: MLT(M) frequency processing

English Edition Rev.04 Mar. 2008 -4- All Rights Reserved.