The Innovative versatile Transport Incubator
works with any environment efficiently.
            INNOVATIVE INFANT TRANSPORT INCUBATOR
     The newborn is not just a bundle of joy. It's a beautiful example of hope and wonder,
     and life itself. To protect it during the critical neonatal stage, and see it glowing with
     health is a labor of love. Neotech infuses the same warmth and dedication into its
     effort in making the finest neonatal intensive care equipment.
     Neotech Incubators, made to international standards, embody Precision,
     Reliability and Convenience.
                                                   Health Care Excellence
INFANT TRANSPORT INCUBATOR
Thermal Performance : The precise Orchid 3000 temperature control
system and excellent temperature maintenance capacity ensure transport
under proper nursing conditions. The spacious incubator maintains a stable
thermal environment even when the ambient air temp is 0 0 C during
transport of Low birth weight infants and high risk neonates.
                                                     Orchid 3000
                                                                     Aninfant's smile is
                                                                     infinitelyprecious.
COMMAND & CONTROL
The Microprocessor controller features a display that is     RETRACTABLE
easy to read at any angle during transport. Servo control    BED SIDE DOOR
Skin and Air Modes helps maintain the temperature.           For respiration tubing
Visual indication for battery power status, power            and others. Way in for
sources and system alarm status are designed to keep         monitor leads and tubes
the care given in command.                                   with no occlusion.
FLEXIBLE POWER SOURCE
                                                             Standard Accessories
                    Invertor is an air (or)
                                                             Observation Lamp, IV Pole,
                    ground transport, power is
                                                             Skin temperature Probe
                    the last thing you should
                    worry about.                             Accessories (Optional)
                    The orchid 3000 from nice                O2 cylinder,
                    neotech operates on AC or                O2 Failure Alarm,
                    DC power using AC when                   O2 Driven Venturi
                    available (or) switching to              Slow Suction
                    its internal battery when
                    necessary for extended
                    length transports.
                    The system can be                               O2 Driven Venturi Slow
                    configured with a second                Suction with humidified oxygen
                    linear battery.
ACCESS MADE EASY                                             INTEGRATED EXAMINATION LIGHT
Access to the infant is quick and easy through the           An integrated examination light provides evenly
front access door and the head door (or) side access         distributed illuminations to the mattress, assisting
doors. The head door folds down and the mattress             you in accurate patient assessment during transport.
retracts out from the hood to provide access for             THE RIGHT SIZE AND WEIGHT : This makes
emergency procedures.                                        transport easy. The nice Neotech Orchid 3000
                                                             transport incubator is designed to fit into smaller
                                                             spaces. System weight has also been reduced to
                                                             enhance mobility and easy access in and out of
                                                             emergency transport vehicle.
                                                             IRIS PORT (Optional)
                                                             An iris port and six tubing ports offer ventilator
                                                             tubing support and entry possibilities for sensors
                                                             while keeping the temperature stable.
                                                             COLLAPSIBLE STAND WITH SHOCK ABSORBERS
                                                             Stainless Steel stand with collapsible for ambulance
                                                             and in hospital transport purposes. Four shock
                                                             absorbers system to allow resistance to peripherals
                                                             as respirators, Infusion pumps and Monitors.
FRONT DOOR                                                   Fixed type trolley (optional), also it absorbs shocks
Total view and access with frontal access panel and          and vibrations during transport.
three entry ports.
INTEGRAL HUMIDIFIER : Humidity is extremely
important especially for babies less than 26 weeks in
gestational age. An integral humidity pad helps
minimize the infants evaporative heat loss by
providing 50-70% humidity in the patient hood for
up to 3 hours.
ACCESSORY SHELF (Optional)
Auxillary tray, Shelf for other additional equipment
as Pulse Oximeter, Respirator with Blender, Infusion
Pump, Oxygen Analyzer.
HOOD OPTIONS :
Single wall Standard
Double wall Optional
Double wall Hood to decrease radiant heat loss
       Standard Features
       Single wall hood, Skin temperature thermistor probe,Air temperature thermistor probe, O2 inlet, Examination Light,
       2 Access Doors, 2 Infant Restraint straps, 1 Iris port (optional), 3 Port doors, 4 Tubing ports, 6 Tubing ports (Optional),
       O2 Failure Alarm (optional), Mattress, Side out mattress deck through head access door.
   Specifications                                                                           Battery specifications
   Electronics                        : Micro Processor Based Design                        Incubator                               : Single Battery (Standard),
   Modes of Operation                 : Skin Servo and Air Servo.                                                                     Double battery (optional)
   Hood                               : Single wall (standard)                              Type                                    :12V, DC, 24AH Lead Acid.
                                        Double wall (Optional)
   Temperature Probe                                                                        Battery Rating                         : Incubator maintains a differential of
   Skin Probe                         : Thermistor Based                                                               25 0C between ambient and set point for 3Hrs
   Air Probe                          : Thermistor Based                                                               on one battery (or) 6Hrs on 2 batteries at full
   Accuracy                           : +/-0.2 0 C                                                                     heater power.
   Probe Interchangeability                                                                 Life expectancy                        : 200 complete charge/discharge
   available                          : +/-0.2 0 C                                                                                   Cycles minimum
                                                                                            Charge Time                            : 10 hours per battery from full
   Thermoregulation                                                                                                                   discharge.
                                                0
   Skin mode control range            : 30-38 C                                             Safety Alarms
   Air mode control range             : 23-390 C                                            High temperature                        : If skin > 0.5 0 C from the set temp
   Skin / Air Mode                                                                          Skin low                                : If skin < 1 0 C from the set temp
   Temperature resolution             : 0.10 C                                              Air temperature high                    : If skin > 0.5 0 C from the set temp
   Skin / Air display                                                                       Air low                                 : If skin < 3 0 C from the set temp
   reading range                       : 20-45 0C                                           Sensor fail                             : If sensor fails
                                                                                                                                                      0
   Temperature rise time              : 100 C within 30 minutes. While                      Low Battery                             : If DC < 10.5 V DC
                                         ambient Temperature is 250 C
                                                                                                                                                               0
                                                                                            Heater fail, Power fail, Air Flow fail, O2 Flow fail (optional), >39 C
   A, 2D (or) 2E size tank mounting : The tank mount permits mounting                       Air/Skin temperature
               gas cylinders with a diameter of up to (12 cms) and
               up to (86 cms) in length.                                                    Silence/Reset                             : Silences the audible portion of
   Humidity Pad                      : Sponge                                                                          alarms for 15 minutes except power fail, sensor
   IV stand                          : Height adjustable Stainless steel                                               fail, heater fail, Air flow.
   Examination Light                 : 11 W CFL with high intensity                         Electrical
   Optional Features                 : Double wall hood, Pressure Regulator,                AC Power Requirements                   : 230 V / 50 Hz.
               Flow meter, Cylinder, Accessory shelf and Oxygen driven                      DC Power                                : 11-13 V/200 W (max)
               Slow suction.                                                                Observation Lamp                        : CFL lamp 10 cm above mattress
   O2 Concentration range            : 21% to 58% minimum                                   Physical characteristic
   Humidity capacity                 : 50% to 70%                                                                  With stand         Without stand
   Noise Level                       : < 60 dBA                                             Height :               Min: 96.3 cm      Min: 56 cm
                                                                                                                   Max:132 cm
   Performance Characteristics                                                              Width :                55 cm           49 cm
   Humidity Pad                       : Holds 400 ml sterile water with no                  Length:                110 cm          97 cm
                                               0
               significant spillage for upto 45 tilt in either direction.                   Weight
   Air filter                         : Removes >99% of air borne                           Single battery:      101.4 kg          71.4 kg
               particle greater than 0.5 micron diameter.                                   Distance from Bed to
   Relative Humidity                  : 50% to 70% for 10-12 hours.                         Vertical hood        25 cm             25 cm
                                                                                            Collapsible Stand
   Control Displays                                                                         Material                            : Stainless Steel
   ON/STAND BY                        : Illuminates when ON                                 Mobility                            : 4 Nos. 6 inches castors (2 brakes)
   Battery Condition Status           : 4 LED indicators                                    Collapsible                         : Yes
   Power Mode                         : Illuminates AC, DC                                  Gas spring                          : 4 nos.
   Heater Power                       : 4 LED indicates heater power                        Environmental
                                        25% to 100%                                         Storage Temperature                 : - 20 0C to 60 0C ambient.
                     0
   Skin Temperature C                 : Displays infant temperature                         Operational Range                   : Sea level to 3 kms (10,000 ft.)
                  0
   Air Temperature C                  : Displays incubator air temperature                                          non-pressurised environment. Sea level to 12
   Air set Temp                       : Air set required temperature                                                kms (40,000 ft) pressurized environment.
   Skin set Temp                      : Skin set required temperature                       Relative Humidity
                                                                                            Operating range                     : 0% to 95% RH, non condensing
   Alarm indicators                  : Air low, Air high, Skin low, Skin high,
              Sensor fail, Heater fail, Air flow, Power fail, Low level battery,            Test & Approval
                             0
              Air/skin > 39 C, O2 failure.                                                  Quality standard                        : ISO 9001:2000& ISO 13485:2003
                                                                                            Electrical safety                       : IEC 60601-1
  *Correct at time of printing. Manufacturer reserves the right to change specifications without prior notice.
  nice - neonatal intensive care equipment
                                                            g
                                                      An ISO 9001:2000, 13485:2003 Company (with Design)
                                               Regd. Office: No: 1. (159) Pallavan Street, Alwarthirunagar, Chennai-600 087
Healthcare Excellence                          Tel: +91- 44- 2486 0652 Fax: 044-2486 8821
                                               Factory: # 85 Krishna Industrial Estate, Mettukuppam, Vanagaram, Chennai - 600 095 India.
                                               Tel: +91-44-24762594, +91-44-24764608 Fax: +91-44-24766920, Mobile: 098408 71902
                                               e-mail: info@niceneotech.com Web: www.niceneotech.com