Troubleshooting
Troubleshooting
TROUBLESHOOTING
1. If the Freezer button and the Fridge button on the Panel PCB are pressed simultaneously for six seconds
  or longer, the Panel Display will turn ON/OFF all displays for about four seconds with an interval of 0.5
  seconds.
  Here, if you take your finger off the Freezer button and the Fridge button and press the Fridge button, the
  product will enter the Test Mode.
2. During the Test Mode, if you press any button from among the buttons on the Panel, it will work as a test
  button.
3. If you press the Test button, it will change in the following order: Forced Operation 1, Forced Operation 2
  (A-Valve/Fan OFF), Forced Operation 3 (F-Valve/Fan OFF), Forced R Defrosting, Forced F/R Defrosting,
  Cancellation (normal operation), and Forced Operation 1.
4. If you want to cancel the Test mode in the middle, please turn OFF the power and turn it ON again.
② ① ② ①
① Press the Freezer button and the Fridge button simultaneously for six seconds.
② When the Display starts blinking, press the Freezer button once.
                                                       27
TROUBLESHOOTING
1. If repeating 3 times switch of 'Coldest' Choices as Rotary Switch and "Dead Zone" over a second choice, a Test key will be
   recognized as a one circuit. However, the choice of "Coldest" and "Dead zone" exceed 5 seconds.
   3 time Count is initialized.
2. If you press the Test button in the normal operation status, the test function will change in the following order: Forced
                                                      Operation 1, Forced Operation 2 (R-Valve/Fan OFF), Forced Operation 3
                                                      (F-Valve/Fan OFF), Forced R Defrosting, Forced F/R Defrosting, Cancellation
                                                      (normal operation), and Forced Operation 1.
                                                      3. If you press the Test button once in the normal mode, the product will enter
                                                         the Forced Operation 1 function.
                                                      3-1) Here, the Buzzer will perform alarm with a beep sound.
                                                      3-2) When forced operation is selected, the Comp. will immediately work without
                                                              the 15-minute delay in any operation mode.
                                                      Here, if the product is defrosting, the defrosting will be immediately stopped, and
                                                      forced operation will be performed.
      (If forced operation is performed immediately when the Comp. is OFF, overload may occur, so be careful.)
      3-3) When forced operation is selected, the Comp. and the F-Fan continues to operate for 24 hours, and the R
             Compartment will work by the set temperature.
      3-4) During forced operation, the alarm will sound until the forced operation will be ended, and you can cancel forced
             operation by repressing the Test button.
4. If you press the Test button again in the Forced Operation 1 status, the product will enter the Forced Operation 2 mode.
      4-1) Here, the Buzzer will perform alarm with a beep sound.
      4-2) When forced operation is selected, the Comp. will immediately work without the 15-minute delay in any operation mode.
             Here, if the product is defrosting, the defrosting will be immediately stopped, and forced operation will be performed.
             (If forced operation is performed immediately when the Comp. is OFF, overload may occur, so be careful.)
      4-3) When forced operation is selected, the Comp. and the F-Fan will continuously work for 24 hours, the R-Valve will be
             closed, and the R-Fan will be OFF.
      4-4) During the forced operation, the alarm will sound until the forced operation will be ended, and if you repress the Test
             button, the Forced Operation 2 mode will be canceled.
5. If you press the Test button again in the Forced Operation 2 status, the product will enter the Forced Operation 3 mode.
      5-1) Here, the Buzzer will perform alarm with a beep sound.
      5-2) When forced operation is selected, the Comp. will immediately work without the 15-minute delay in any operation mode.
             Here, if the product is defrosting, the defrosting will be immediately stopped, and forced operation will be performed.
             (If forced operation is performed immediately when the Comp. is OFF, overload may occur, so be careful.)
      5-3) When forced operation is selected, the Comp. and the R-Fan will continuously work for 24 hours, the F-Valve will be
             closed, and the F-Fan will be OFF.
      5-7) During forced operation, the alarm will sound until the forced operation will be ended, and you can cancel the Forced
             Operation 3 by repressing the Test button in the Forced Operation 3 status.
6. In the Forced Operation 3 status, if you press the Test button again, the Forced Operation 3 will be immediately canceled,
     and the product will enter the Forced R Defrosting mode.
      6-1) Here, a beep alarm sound will be made for three seconds from when you enter the mode, and continue to be made by
             being ON for 0.1 seconds and being OFF for 0.9 seconds in the Forced R Defrosting mode.
7. If you press the Test button again in the Forced R Defrosting status, the Forced R Defrosting will be immediately canceled,
     and the product will enter the Forced FR Defrosting mode.
      7-1) Here, a beep alarm sound will be made for three seconds from when you enter the mode, and continue to be made by
             being ON for 0.5 seconds and being OFF for 0.5 seconds in the Forced FR Defrosting mode.
[Reference]
Dead zone : If do not set a specific Notch, set between Notch, It is recognized as not the middle value but abnormal
range. This is called Dead zone.
                                                                   TEST KEY
                                                                     INPUT
                                                                   28
TROUBLESHOOTING
1-1) If you press any button once in the Test Mode, the product will enter the Forced Operation 1 mode.
     When the product enters the Forced Operation 1 mode, the Panel Display will display the LEDs from
     Weak, Weak Middle, Middle, and Middle Strong to Strong of the F/R Compartments.
     Here, the Buzzer will perform alarm with a beep sound.
1-2) When forced operation is selected, the Comp. will immediately work without the 15-minute delay in any
       operation mode.
       Here, if the product is defrosting, the defrosting will be immediately stopped, and forced operation will
       be performed.
       (If forced operation is performed immediately when the Comp. is OFF, overload may occur, so be
       careful.)
1-3) When forced operation is selected, the Comp. and the F-Fan continues to operate for 24 hours, and the
       R Compartment will work by the set temperature.
1-4) When forced operation is selected, the set temperature will be automatically selected to be -23℃ for
       the Freezer and 1℃ for the Fridge.
1-5) During forced operation, the Power Freeze and Power Cool functions will not work.
       (All the buttons function normally)
       If the function is selected, the Power mode icon will be automatically turned OFF in about 10 seconds.
1-6) If you select the forced defrosting or the test cancellation when one minute has not passed after you
       have selected forced operation, the set temperature will be changed into the previous set temperature.
1-7) During forced operation, the alarm sound will not stop until the forced operation is finished.
[Note] Models with the Rotary Switch operate the same as the above with the Forced Operation Mode on.
                                                      29
TROUBLESHOOTING
2-1) If you press any button twice in the Test mode, the product will enter the Forced Operation 2 mode.
     When the product enters the Forced Operation 2 mode, the Panel Display will display the LEDs from
     Weak and Weak Middle to Middle of the F/R Compartments.
     Here, the Buzzer will perform alarm with a beep sound.
2-2) When forced operation is selected, the Comp. will immediately work without the 15-minute delay in any
       operation mode.
       Here, if the product is defrosting, the defrosting will be immediately stopped, and forced operation will
       be performed.
       (If forced operation is performed immediately when the Comp. is OFF, overload may occur, so be
       careful.)
2-3) When forced operation is selected, the Comp. and the F-Fan will continuously work for 24 hours, the
       R-Valve will be closed, and the R-Fan will be OFF.
2-4) When forced operation is selected, the set temperature will be automatically selected to be -23℃ for
       the Freezer and 1℃ for the Fridge.
2-5) During forced operation, the Power Freeze and Power Cool functions will not work.
       (All the buttons function normally)
       If the function is selected, the Power mode icon will be automatically turned OFF in about 10 seconds.
2-6) If you select the forced defrosting or the test cancellation when one minute has not passed after you
       have selected forced operation, the set temperature will be changed into the previous set temperature.
2-7) During forced operation, the alarm sound will not stop until the forced operation is finished.
[Note] Models with the Rotary Switch operate the same as the above with the Forced Operation Mode on.
                                                       30
TROUBLESHOOTING
3-1) If you press any button three times in the Test mode, the product will enter the Forced Operation 3
     mode.
     When the product enters the Forced Operation 3 mode, the Panel Display will display the LEDs of Weak
     and Weak Middle of the F/R Compartments.
     Here, the Buzzer will perform alarm with a beep sound.
3-2) When forced operation is selected, the Comp. will immediately work without the 15-minute delay in any
       operation mode.
       Here, if the product is defrosting, the defrosting will be immediately stopped, and forced operation will
       be performed.
       (If forced operation is performed immediately when the Comp. is OFF, overload may occur, so be
       careful.)
3-3) When forced operation is selected, the Comp. and the R-Fan will continuously work for 24 hours, the
       F-Valve will be closed, and the F-Fan will be OFF.
3-4) When forced operation is selected, the set temperature will be automatically selected to be -23℃ for
       the Freezer and 1℃ for the Fridge.
3-5) During forced operation, the Power Freeze and Power Cool functions will not work.
       (All the buttons function normally)
       If the function is selected, the Power mode icon will be automatically turned OFF in about 10 seconds.
3-6) If you select the forced defrosting or the test cancellation when one minute has not passed after you
       have selected forced operation, the set temperature will be changed into the previous set temperature.
3-7) During forced operation, the alarm sound will not stop until the forced operation is finished.
[Note] Models with the Rotary Switch operate the same as the above with the Forced Operation Mode on.
                                                       31
TROUBLESHOOTING
4-1) In the Forced Operation 3 status of Test Mode, if you press any button once more, the Forced Operation
     3 will be immediately canceled, and the product will enter the Forced R Defrosting mode.
     When the product enters the Forced R Defrosting mode, the Panel Display will display the LEDs of Weak
     Middle and Middle of the F/R Compartments.
4-2) Here, a beep alarm sound will be made for three seconds from when you enter the mode, and continue
       to be made by being ON for 0.1 seconds and being OFF for 0.9 seconds in the Forced R Defrosting
       mode.
[Note] Models with the Rotary Switch operate the same as the above with the Forced Operation Mode on.
5-1) In the Forced R Defrosting status of Test Mode, if you press any button once more, the Forced R
     Defrosting will be immediately canceled, and the product will enter the Forced FR Defrosting mode.
     When the product enters the Forced FR Defrosting mode, the Panel Display will display the LED of
     Middle of the F/R Compartments.
5-2) Here, a beep alarm sound will be made for three seconds from when you enter the mode, and continue
       to be made by being ON for 0.5 seconds and being OFF for 0.5 seconds in the Forced FR Defrosting
       mode.
[Note] Models with the Rotary Switch operate the same as the above with the Forced Operation Mode on.
                                                    32
TROUBLESHOOTING
                                                      33
TROUBLESHOOTING
                                                             ①E
                                                               RROR DISPLAY
                                                              (Refer to Self-Diagnosis
                                                              Check List below)
                   "-21℃" LED
 2   EXT-SENSOR                 Open/Short error
                      Lamp
                   "-19℃" LED
 3    F-SENSOR                  Open/Short error
                      Lamp
                   "-17℃" LED
 4    R-SENSOR                  Open/Short error
                      Lamp
                                                     34
TROUBLESHOOTING
                           "-15℃" LED
 5   R-DEF SENSOR                         Open/Short error
                              Lamp
                            Vacation
 9   R-DEF SENSOR                         Open/Short error
                       (          ) LED
                       Power Freeze
10   R-FAN ERROR                          R-FAN constraint error
                       (          ) LED
                                                                 35
TROUBLESHOOTING
                           Separation of sensor
                           housing part, contact error,
                           disconnection, short circuit.
                                                             The voltage between MAIN PCB
                 F - DEF - The failure by temperature
 3                                                           CN30-"4(YEL) ↔ 1(WHT)" should be
                  SENSOR is displayed when the
                                                             within 4.5V~0.5V.
                           temperature sensed by the
                           sensor is +65℃ or higher or
                           -50℃ or lower.
                                                                      36
TROUBLESHOOTING
                 WATER
                                                             The voltage between MAIN PCB
                  PIPE    Separation of sensor
 9                                                           CN30-"3(GRN) ↔ 1(WHT)" should
                 HEATER   housing part, contact error,       be within 4.5V~0.5V.
                 ERROR    disconnection, short circuit.
                          The failure by temperature
                          is displayed when the
                          temperature sensed by the
                          sensor is +65℃ or higher or
                          -50℃ or lower.
                ICE MAKER **Applies only to the models       The voltage between MAIN PCB
10                SENSOR with Ice Maker                      CN30-"3(GRN) ↔ 1(WHT)" should
                   ERROR                                     be within 4.5V~0.5V.
                                                                      37
TROUBLESHOOTING
                COMP Over The error code is displayed        Check the input voltage.
17               Voltage when the AC Input Voltage is        (This error occurs when the input
                 ERROR    too high.                          voltage is AC 310V or higher.)
                                                                      38
TROUBLESHOOTING
1. When the unit is plugged in, it will diagnose all its components to check if there are any defect parts.
  And when there is any defect part, the ERROR MODE DISPLAY LED LAMP will blink according to the LED
  Blinking Frequency in the below table. And, at the end of each blinking cycle, there is a two-second
  interval (Downtime).
2. When the unit is plugged in, it will also diagnose if there are any multiple parts or loads failures. If so, the
   ERROR MODE DISPLAY LED LAMP will blink according to the LED Blinking Frequency in the below table.
   And, at the end of each blinking cycle, there is a two-second interval (Downtime).
                                                (552502'(',63/
                                                   $</('/$03
              LED
  No        Blinking                 Item                                     Trouble Shooting
           Frequency
   1         1 Times               F-Sensor          Open/Short error
                                                         39
TROUBLESHOOTING
            LED
 NO       Blinking          Item                          Description                                    Trouble Shooting
         Frequency
                                         Connector Slipped-Out or Open-Contact,
                                                                                          The voltage between MAIN PCB CN30-
                                         Wire Cut or Short-Circuited, Abnormal
 1         1 Times        F-Sensor                                                        "4(RED) ↔ 7(Gray)" should be within
                                         Sensing Temp (higher than +65℃ or lower
                                                                                          4.5V~0.5V.
                                         than -50℃)
                                         Connector Slipped-Out or Open-Contact,
                                                                                          The voltage between MAIN PCB CN30-
                                         Wire Cut or Short-Circuited, Abnormal
 2         Twice      F-DEF -SENSOR                                                       "4(RED) ↔ 7(Gray)" should be within
                                         Sensing Temp (higher than +65℃ or lower
                                                                                          4.5V~0.5V.
                                         than -50℃)
                                         Connector Slipped-Out or Open-Contact,
                                                                                          The voltage between MAIN PCB CN31-
                                         Wire Cut or Short-Circuited, Abnormal
 3        3 Times       EXT-SENSOR                                                        "1(WHT) ↔ 2(WHT)" should be within
                                         Sensing Temp (higher than +65℃ or lower
                                                                                          4.5V~0.5V.
                                         than -50℃)
                                         PBA-Rotary Switch Slipped-Out or Open-           The voltage between MAIN PCB CN30-
 4         4 Times     F-Rotary ERROR Contact, Wire Cut or Short-Circuited,Switch         "3(BRN)↔ 7(Gray)" should be within
                                         Part Defect                                      4.5V~0.5V.
                                         [ Freezer Defrost Heater ]                       Remove the MAIN PCB CN70 and CN77
                                         Connector Slipped-Out or Open-Contact,           connectors from the MAIN PCB and read the
                                         Wire Cut or Short-Circuited, Defective           continuity between BROWN ↔ ORG wires. (It
 5        5 Times      F-DEF-ERROR Thermistor                                             differs according to the energy consumption.)
                                         Freezer Defrost When the defrosting does         When it reads 0 Ohm, check the Heater
                                         not complete even after it does defrosting for   short and when it reads ∞ Ohm, check if the
                                         more than 120 minutes.                           Wire/Thermal Fuse or the Bimetal is Open.
                                         Connector Slipped-Out or Open-Contact,
                                                                                          The voltage between MAIN PCB CN30-
                                         Wire Cut or Short-Circuited, Abnormal
 6        6 Times        R-SENSOR                                                         "5(ORG) ↔ 7(Gray)" should be within
                                         Sensing Temp (higher than +65℃ or lower
                                                                                          4.5V~0.5V.
                                         than -50℃)
                                         Connector Slipped-Out or Open-Contact,
                       R-DEF SENSOR Wire Cut or Short-Circuited, Abnormal                 The voltage between MAIN PCB CN30-
 7         7 Times                                                                        "5(ORG) ↔ 7(Gray)" should be within
                           ERROR         Sensing Temp (higher than +65℃ or lower
                                                                                          4.5V~0.5V.
                                         than -50℃)
                                         PBA-Rotary Switch Slipped-Out or Open-           The voltage between MAIN PCB CN30-
 8        9 Times       R-Rotary Error Contact, Wire Cut or Short-Circuited,Switch        "3(BRN)↔ 7(Gray)" should be within
                                         Part Defect                                      4.5V~0.5V.
                      Comp start failure The error code is displayed when the             Check the soldering status of the inverter
                            error        compressor has failed to start.                  PCB. (Check if any parts have short-
                      Compressor IPM The error code is displayed when the                 circuited). Check if the DC 16V output is less
                         Fault Error     compressor IPM fault error has occurred.         than 13.5V. Check the Comp and Cycle.
                                                                                          Check the compressor wire connections. Check the
                       Comp location      The error code is displayed when the            soldering status of the inverter PCB. (Check if any
                       detection error    compressor location detection failed.           parts have short-circuite d). Check the Comp and
 9        10 Times                                                                        Cycle.
                                                                                          Check if the compressor and the Cycle is
                        Comp motor        The error code is displayed when the            normal. Check the input voltage.
                       constraint error   compressor motor is constrained.                Check the soldering of the inverter PCB.
                                                                                          (Check if any parts have short-circuited.)
                      Comp low voltage    The error code is displayed when the AC         Check the input voltage. (This error occurs
                            error         Input Voltage is too low.                       when the input voltage is AC 106 V or lower.)
                         Comp over        The error code is displayed when the AC         Check the input voltage. (This error occurs
                        voltage error     Input Voltage is too high.                      when the input voltage is AC 310V or higher.)
                                          When the related Fan Motor operates, it
                                          occurs if the contact of the Feed Back Signal   The voltage between MAIN PCB CN72-
 10        11 Times    F-FAN ERROR
                                          Wire is defective, the Motor Wire is slipped    "9(PNK) ↔ 10(GRY)" should be within 7V~12V
                                          out or the Motor is defective.
                                          When the related Fan Motor operates, it
                                          occurs if the contact of the Feed Back Signal   The voltage between MAIN PCB CN72-
 11        12 Times    R-FAN ERROR
                                          Wire is defective, the Motor Wire is slipped    "9(PNK) ↔ 10(GRY)" should be within 7V~12V
                                          out or the Motor is defective.
                                                                40
TROUBLESHOOTING
1) If the Freezer + Fridge buttons are pressed simultaneously for about seven seconds during normal
   operation mode, the Panel Display will turn ON/OFF the LEDs of Weak Middle, Middle, and Middle Strong
   for about four seconds.
2) Here, if you take your fingers off the buttons and press the Fridge button (a "Ding-Dong" sound will be
     made and), the mode will be converted into the Load Status Display Function.
3) The Load Status Display function lets you know what the load for the current output of the Micom signal is.
     However, it just means that the Micom signal is outputted, and does not confirm whether the load is
     actually working or not.
     That is, even if it displays that the load is working, the load may not be working because of a disorder of
     the actual load or a faulty Relay on the PCB.
     (You need to check.)
4) The Load Status Display Function lasts only for 30 seconds, and the product will automatically return to the
     normal status after that.
5) The display of each load status is as follows:
① ② ① ②
                                                       41
※ Load Mode Check List
 NO           Item          Display                             Description
1) When the Panel Display is initialized in case of a temporal blackout, a non-sense call by consumers may
   occur.
   In order to prevent this, the product senses the temperature inside the Refrigerator at the point when the
   power is applied and initializes or recovers the existing operation status.
2) When the power is initially ON, the product senses the temperature inside the Freezer, Fridge, Freezer
    Defrosting Sensor, and of the Fridge Defrosting Sensor. If at least one from among the four temperatures
    is less than about +12℃, the product regards this as a temporal blackout during operation, and recovers
    the functions related to the Panel Display (Power Freeze, Power Cool, Fridge, Freezer, Door Alarm, Lock
    function, etc.).
3) When the power is initially ON, the product senses the temperature inside the Freezer, Fridge, Freezer
    Defrosting Sensor, and of the Fridge Defrosting Sensor. If all the four temperatures are about +12℃ or
    higher, the product regards this as a blackout for a long time, and initializes the Panel Display.
    (The temperature of the Freezer is -19℃. The temperature of the Fridge is 3℃. The Door Alarm ON is
    automatically set.)
1) If the Freezer + Fridge buttons are pressed simultaneously for about seven seconds during normal
   operation mode, the Panel Display will turn ON/OFF the LEDs of Weak Middle, Middle, and Middle Strong
   for about four seconds.
2) Here, if you take your fingers off the buttons and press the Freezer button, (a "Ding-Dong" sound will be
     made and) the product will be converted into the Exhibition mode.
3) When the Exhibition Mode is set, the Display and all functions will normally work, and only the Compressor
     won't start.
4) The Exhibition Mode will be canceled if you press the Exhibition Mode button again or turn OFF the power.
5) During the Exhibition Mode, when the temperature of the Freezer or the Fridge increases to be 65 ℃ or
     higher, the Exhibition Mode will be canceled, and the product will enter the cooling operation condition.
② ① ② ①
                                                      43
TROUBLESHOOTING
1) During the Normal Operation, press the Freezer + Fridge buttons for 4 seconds.
  Then, the entire Display Panel will blink at the interval of 0.5 seconds for 3 seconds.
2) At this time, release the Freezer + Fridgel buttons and press the Power Cool button (it sends out "Ding
  Dong" sound.) Then, it shifts to the Option Setting Mode.
● When there is no button press for 20 seconds at the Option Setting Mode, it will go back to the normal
    display mode.
① ② ① ②
① Press the Freezer + Fridge buttons for 4 seconds at the same time.
 Then, the Display LEDs will blink for 3 seconds. At this time, release the buttons
② and, press the Fridge button once.
                                                        44
TROUBLESHOOTING
                                                             ④                               ③
                         ④                                   ③
② ① ② ①
● The Bar Type Display Panel shows the numbers as shown in the following tables (Binary Type)
   Value
             0     1     2     3     4    5    6     7    8      9     10    11     12   13   14                15
  F     R
-23℃ 1℃                                                                                          
-21℃ 2℃                                                                                          
-19℃ 3℃                                                                                          
-17℃ 5℃                                                                                          
-15℃ 7℃                                                                                          
   Value
              16    17       18       19   20   21      22       23       24   25   26   27      28   29   30   31
  F     R
-23℃ 1℃                                                                                          
-21℃ 2℃                                                                                          
-19℃ 3℃                                                                                          
-17℃ 5℃                                                                                          
-15℃ 7℃                                                                                          
                                                        45
TROUBLESHOOTING
 ● When the Display Panel converts to the Option Setting mode, the entire Display except the Freezer and
  the Fridge Temperature LEDs as shown below Temp LED goes off.
 1) For example, if you want to shift the standard temp of the Freezer compartment by -2℃, follow the steps
   below. This function is to change the default temperature and when the default temperature of the Freezer
   compartment is -21℃ and the default setting is lowered by -2℃ with the Option function, the default
   temperature will be controlled at -23℃. That is, when changing temperature options, the Freezer
   compartment will operate at -23℃ internally even if it shows -21℃ on the display panel. Therefore, the
   temperature will be controlled by -2℃ lower than the set temperature on the display panel.
 Note Basically, when units being shipped out, all the data in the Option function are cleared. That is, the
     Default settings are “0”. However, for the purpose of quality improvement during mass production, the
     Default values may change. Therefore, be sure to check quality information, such as SVC bulletins.
 2) After changing into the Option mode,“0" on both of the Fridge and Freezer compartments lights up on the
   display panel. (when units being shipped out, the unit will be shipped out with "0"s set on both of the
   Fridge and Freezer compartments. However, for the purpose of quality improvement during mass
   production, the Default values may change.)
 - When the Fridge Display set to the status of the Option #0, it will be set to the Freezer Temperature
  Option and the current Freezer Temperature Set Value will be shown on the Freezer Temperature Display
  (Refer to the Freezer Temp Shifting Image).
 3) When "4" is set as shown in the Freezer Option Table below after setting the Fridge Option # to "0", the
   Freezer default temperature will decrease by -2℃. (Refer to the Freezer Temp Shift Figure)
   :In 20 seconds after completing the adjustment, MICOM is to store the setting value in EEPROM and it
   goes back to the normal display mode, deactivating the Option Setting mode.
 5) The Fridge temperature can be adjusted with the same method.
 6) Make sure not to change the factory-set default values excluding exceptional circumstances.
   Also, the Option Setting will be completed when it goes back to the normal display mode in 20 seconds.
   So, do not turn off the unit before it goes back to the normal display mode.
                                                     46
TROUBLESHOOTING
  Note There are other option setting functions. But, it's got to do with the performance of the unit, not for
      repair purposes. So, they are not handled in this manual.
      (Except those described in this manual, do not change other values.)
       Setting Value
  Freezer Temp Display        Option Value
     Panel Set Value
             0                     0
             1                   -0.5℃
             2                   -1.0℃
             3                   -1.5℃
             4                   -2.0℃
             5                   -2.5℃
             6                   -3.0℃
             7                   -3.5℃
             8                  +0.5℃
             9                  +1.0℃
            10                  +1.5℃
            11                  +2.0℃
            12                  +2.5℃
            13                  +3.0℃
            14                  +3.5℃
            15                  +4.0℃
                                                       47
TROUBLESHOOTING
       Setting Value
  Freezer Temp Display       Option Value
     Panel Set Value
             0                    0
             1                  -0.5℃
             2                  -1.0℃
             3                  -1.5℃
             4                  -2.0℃
             5                  -2.5℃
             6                  -3.0℃
             7                  -3.5℃
             8                 +0.5℃
             9                 +1.0℃
            10                 +1.5℃
            11                 +2.0℃
            12                 +2.5℃
                                                            Ex) When shifting the Fridge default temp by +2.0℃
            13                 +3.0℃
            14                 +3.5℃
            15                 +4.0℃
                                                    48
TROUBLESHOOTING
    Setting Value
    Freezer Temp        Option Value
    Display Panel
      Set Value
          0              Display OFF
          1           Always Display On
          2           Always Display On
                                                    49
TROUBLESHOOTING
      Setting Value
  Freezer Temp Display    Option Value
     Panel Set Value
            0                  0
            1                -0.5℃
            2                -1.0℃
            3                -1.5℃
            4                +0.5℃
            5                +1.0℃
            6                +1.5℃
            7                +2.0℃
                                                        Ex) W
                                                             hen lowering the default temperature by 0.5℃ in
                                                            F-Convert mode
                                                  50
TROUBLESHOOTING
    Setting Value
    Freezer Temp         Option Value
    Display Panel
      Set Value
          0              5.9 seconds
1 6.4 seconds
                                                        Ex) When increasing the water supply for the Ice Maker
                                                           (Time spent: 5.9 Sec. -> 6.4 Sec.)
                                                  51
TROUBLESHOOTING
       Setting Value
   Freezer Temp Display     Option Value
      Panel Set Value
             0                   90
             1                   91
             2                   92
             3                   93
             4                   94
             5                   95
             6                   96
             7                   97
             8                   98
             9                   99
            10                  100
            11                   89
            12                   88
                                                             Ex) When extending the waiting time by five minutes
            13                   87
            14                   86
            15                   85
                                                        52
TROUBLESHOOTING
       Setting Value
   Freezer Temp Display     Option Value
      Panel Set Value
             0                -15.0℃
             1                -14.0℃
             2                -13.0℃
             3                -12.0℃
             4                -11.0℃
             5                -16.0℃
             6                -17.0℃
             7                -18.0℃
                                                          Ex) W
                                                               hen lowering the separating temperature by
                                                              3.0℃ against the default value
                                                     53
TROUBLESHOOTING
DATA1.Temp Table
Conversion Table - Temperature/MICOM PORT Voltage/Resistance
SENSOR CHIP : PX41C
                                                   54
TROUBLESHOOTING
-T  he Display Panel shows the Sensor Error and, when the unit is plugged in and there are sensor errors,
  the unit does not operate and Display bar related to the defective sensors keep blinking.
- When sensor defects occur during the operation, the unit keeps working. But, it shifts to the Emergency
  Operation and it may not work properly. So, please check the unit according to the Self Diagnosis function.
ERROR CODE
Start
                                                       R Sensor is              No
        DATA1. Temp Table                               normal?
                                                                Yes
** Sensor Resistance Reading Location **                                                       Replace Temp Sensor
R : R:Between CN31 #7 and #8
** 0Ω : Short / ∞Ω : Open                             Voltage between           NO(Value < 0.6V or Value > 4.6V)
                                               MAIN PCB Connector CN31 #7 and
                                                         CN31 #8?
   Refer to Circuit Diagram
                                                                Yes                          Check the wire connection
  Sensor MICOM/Connector #
                                                 Input Voltage at IC10          No
 R     R:Between CN31 #7 and #8                MICOM PIN #54 is normal?
                                                             55
TROUBLESHOOTING
ERROR CODE
Start
                                                                                 No
       DATA1. Temp Table                      R-DEF-Sensor is normal?
                                                           56
TROUBLESHOOTING
ERROR CODE
Start
                                                               57
TROUBLESHOOTING
ERROR CODE
Start
                                            Voltage between Main PCB connector   No   NO(Value < 0.6V or Value > 4.6V)
                                                  CN30-”7” and CN30-”8”?
   Refer to Circuit Diagram
                                                               Yes                           Check the wire connection
  Sensor MICOM/Connector #
            Between Connector                Input voltage at IC10 Micom         No
R-DEF
           CN30 –”7” and CN30-”8”                Pin #52 is normal?
 Voltage : Between 4.6V ~ 0.6V                                 Yes                        Check Soldering Defect & Short
                                                            58
TROUBLESHOOTING
ERROR CODE
Start
                                                   F-DEF Sensor is               No
       DATA1. Temp Table                              normal?
                                                              Yes
**Sensor Resistance Reading Location**                                                           Replace Temp Sensor
**F-DEF : Between CN30 #5 and #6
**Located in the PCB Box
**0Ω : Short / ∞Ω : Open                    Voltage between Main PBA Connector   NO(Value < 0.6V or Value > 4.6V)
                                                   CN30-”5” and CN30-”6”
   Refer to Circuit Diagram
                                                              Yes                             Check the wire connection
  Sensor MICOM/Connector #
 F  Between Connector CN30-                 Input Voltage at IC10 MICOM          No
DEF     ”5” And CN30-”6”                          pin #51 is normal?
Voltage : Between 4.6V ~ 0.6V                                 Yes                           Check Soldering Defect & Short
                                                            59
TROUBLESHOOTING
4-2-2. When the Freezer Fan does not operate (BLDC Motor)
F FAN ERROR
Start
                                                                                     Yes
                                                   The Compressor is Off.
                                                     It reads DC7~12
                                                                                     Yes
                                                    between MAIN PCB
                                                    GND and CN30 #10
                                                                                                                         No
                                                                 No                                FAN operates.
Upon the initial power on, the compressor
and the F-Fan operate.                         Apply power in 7 minutes after
                                            turning the motor off. (To prevent the
And, when the Fridge temp is lower than     compressor from being overloaded)
12℃, it will be regarded as an instant
power failure, starting in 7 minutes.                            Yes
                                              Does it repeat DC 7~12V (between
                                              Main PCB GND and CN30 #10) and          No
                                            lower than DC 2V (between Main PCB
                                                     GND and CN30 #9 ?
                                                                 Yes                            Replace MAIN PCB
                                                            ◆ Possible Causes
                                                            ① Defective FAN-MOTOR
                                                            ② Contact problem at the terminal (MAIN PCB CONNECTOR-
                                                             TERMINAL (CN 30 #9, #10, #11), Contact problem at Freezer
                                                             Fan Motor Connector, Defective Motor Wire)
                                                            ③ Check the motor rotating pulse input upon Fan Motor
                                                              operation. (Refer to Fan-Motor Circuit in this manual)
                                                            60
TROUBLESHOOTING
F FAN ERROR
Start
                                                                                     Yes
                                                   The Compressor is Off.
                                                      It reads DC7~12
                                                                                     Yes
                                                     between MAIN PCB
                                                     GND and CN31 #9
                                                                                                                        No
                                                                 No                               FAN operates.
Upon the initial power on, the compressor
and the R-Fan operate.                         Apply power in 7 minutes after
                                            turning the motor off. (To prevent the
And, when the Fridge temp is lower than     compressor from being overloaded)
12℃, it will be regarded as an instant
power failure, starting in 7 minutes.                            Yes
                                               Does it repeat DC 7~12V (between
                                            Main PCB GND and CN31 #9) and lower       No
                                             than DC 2V (between Main PCB GND
                                                         and CN31 #8 ?
                                                                 Yes                           Replace MAIN PCB
                                                            ◆ Possible Causes
                                                            ① Defective FAN-MOTOR
                                                            ② Contact problem at the terminal (MAIN PCB CONNECTOR-
                                                             TERMINAL (CN 31 #8, #9, #10), Contact problem at Freezer
                                                             Fan Motor Connector, Defective Motor Wire)
                                                            ③ Check the motor rotating pulse input upon Fan Motor
                                                             operation. (Refer to Fan-Motor Circuit in this manual)
                                                            61
   TROUBLESHOOTING
       4-2-4. When Defrost does not work (F DEF Heater)
     -W
       hen there is a trouble in defrosting, select the Self-Diagnosis function before turning off the unit. And,
      check if there is any defect in the Defrost Heater. If not, plug out the unit and do the Trouble-Shooting. (Refer
      to the Self-Diagnosis function and check the details)
                                                                                                    ☞ When checking with the
                                                                                     F DEF. ERROR    Self Diagnosis
                                                                         Start
** Heater Resistance Reading Location **
F-DEF : Resistance between CN72 #5 ↔
CN73 #1 should be ohm ± 10%.
** 0Ω : Short / ∞Ω : Open
(Bimetal / Thermal Fuse / Heater Defect)                         All Defrost Heaters            No
                                                                     are normal?
** Sensor Resistance Reading Location **
F-DEF : Between CN30 #7 ↔ CN30#8
                                                                              Yes
** 0Ω : Short / ∞Ω : Open
                                                                                                               Check Bimetal, Heater
      Temp vs. Resistance Table                                                                             Continuity or Wire Connection
                                                                 Defrost Sensor is              No
    30℃              4.22㏀                                       normal? (Check it
    20℃              6.05㏀             For more                 with Self-Diagnosis)
    10℃              8.87㏀            detail data,                                                       Replace the Sensor
     0℃             13.29㏀              refer to                              Yes
   -10℃             20.42㏀           DATA1. Temp
   -20℃             32.23㏀               Table
   -30℃             52.41㏀                                             The Sensor               No
                                                                  Temperature Value
** Sensor Voltage Reading Location **                             is lower than 12℃.
F-DEF : Between PCB COMMON Ground                                                                    Forced Operation for a while
and CN30 #5 (or SEN_2)                                                        Yes
** 0V : Short / 5V : Open
                                                                                  62
TROUBLESHOOTING
Caution
There is AC220~240V or                                                      - When checking the MAIN PCB, refer
DC310~340V at the MAIN PCB                          Start                     to the Operation descriptions and
Power Circuit. So, be cautious                                                the "Reference" section.
when repairing the unit or
measuring values.                                                     No
                                            The unit is plugged in?                     Plug in the unit
                                                         Yes
                                                                      No
                                             220~240V is applied
                                                at MAIN PCB                       Check the wire connections
                                              CN71 terminals?
                                                         Yes
                                                                      Yes
                                                                               1) Replace Fuse (AC 250V 2.0A)
                                           MAIN PCB Fuse is blown?
                                                                               2) Replace PCB ASS'Y
                                                         No
                                                                      No
                                            DC310~340V is applied                    Replace PCB ASS'Y
                                             at BD101 terminals?
                                                         Yes
                                                                      No
                                             DC 6.2V is applied at                   Replace PCB ASS'Y
                                            TOP S/W 3-12(BETTER)
                                                         Yes
                                                                      No
                                              12V is applied at
                                                                                     Replace PCB ASS'Y
                                              CE101 terminals?
                                                         Yes
                                                                      No
                                               5V is applied at
                                                                                     Replace PCB ASS'Y
                                              CE105 terminals?
                                                         Yes
                                                                      No
                                             Panel PCB operates               1) Check the wire connections
                                                 normally?                    2) Replace Panel PCB
                                                         Yes
                                                                      No
                                             Loads such as Relay              1) Check Lead Wire connections
                                              operate normally?               2) Replace Relay or PCB ASS'Y
                                                         Yes
                                                                      Yes
                                              Is there PCB Short              1) Do Re-soldering
                                                  or breakage?                2) Replace PCB MAIN
   - Check the connection of Door Panel
     PCB                                                 No
                                             Normal (Check again)
                                                       63
TROUBLESHOOTING
Caution
There is AC 110~127V or DC                                                  - When checking the MAIN PCB, refer
156~180V at the MAIN PCB                            Start                     to the Operation descriptions and
Power Circuit. So, be cautious                                                the "Reference" section.
when repairing the unit or
measuring values.                                                     No
                                            The unit is plugged in?                     Plug in the unit
                                                         Yes
                                                                      No
                                             110~127V is applied
                                                at MAIN PCB                       Check the wire connections
                                              CN71 terminals?
                                                         Yes
                                                                      Yes
                                                                               1) Replace Fuse (AC 250V 2.0A)
                                           MAIN PCB Fuse is blown?
                                                                               2) Replace PCB ASS'Y
                                                         No
                                                                      No
                                           DC 156~180V is applied                    Replace PCB ASS'Y
                                            at BD101 terminals?
                                                         Yes
                                                                      No
                                             DC 6.2V is applied at
                                            TOP S/W 3-12(BETTER)                     Replace PCB ASS'Y
                                                 2-8(GOOD)?
                                                         Yes
                                                                      No
                                              12V is applied at
                                                                                     Replace PCB ASS'Y
                                              CE102 terminals?
                                                         Yes
                                                                      No
                                               5V is applied at
                                                                                     Replace PCB ASS'Y
                                              CE105 terminals?
                                                         Yes
                                                                      No
                                             Panel PCB operates               1) Check the wire connections
                                                 normally?                    2) Replace Panel PCB
                                                         Yes
                                                                      No
                                             Loads such as Relay              1) Check Lead Wire connections
                                              operate normally?               2) Replace Relay or PCB ASS'Y
                                                         Yes
                                                                      Yes
                                              Is there PCB Short              1) Do Re-soldering
                                                  or breakage?                2) Replace PCB MAIN
   - Check the connection of Door Panel
     PCB                                                 No
                                             Normal (Check again)
                                                       64
  TROUBLESHOOTING
                                                                  10 minutes have             No
                                                                passed since COMP
                                                                      was off
                                                                           Yes
                                                                                                            Check in 10 minutes
                                                                                             No
Refer to Test Function in this                                When Forced Operation
manual                                                    mode is activated, COMP operates
                                                                                                                                          No
                                               Yes
                                                                                                   Temperature Sensor is normal?
Forced Operation signal                                                    Yes
sound should be checked
                                                                                                                   Yes
0~800Hz 50% Duty Signal                                                                                                            Replace the Sensor
Output
                                                                                                                                          No
                                                                                                       Temperature sensing
                                                                                                     part of MAIN PBA is Good
                                                     No           COMP operation
                                                               Signal(CN201 ①↔③) is
                                                                                                                                  Repair the sensing
                                                               High(about DC 2-2.5V                                Yes
                                                                   or AC 0~5.0V)                                              part or Replace MAIN PBA
                                                                                  65
  TROUBLESHOOTING
[Note]
1. Fridge / Freezer Door Open Alarm : It sends out an alarm sound when it passes over 2 minutes after the door is open. And,
   when the door remains open, it will keeps alarming every minute.
2. When the door is not closed properly, MICOM recognizes it as Door Open and sends out an alarm sound. When it passes
   over 10 minutes after it recognizes the Door Open, the room lamps will be off. At this time, when the Door is completely
   open, the Lamp will not be on right away, but after a while.
Start
                                                                                      Gap exists
                                                           Door stays open?
                                                          Connector (CN31) is         No
                                                           inserted properly?
                                                                            Yes                    Insert the Connector
     Remove and measure the continuity of
     Door S/W by pressing it (On/Off).                    Door S/W is in good         No
     Check if the value changes between                       condition?
     0Ω and ∞Ω.
                                                                            Yes                    Replace Door S/W
                                                        Check MAIN PCB and
                                                             Door S/W
Start
③ No Buzzer Sound
Start
                                                           67
TROUBLESHOOTING
                                          It lights up when
                                                                  Yes
                                        PANEL-PCB is being
                                                replaced
                                                      No
                                                                               Defective PANEL PCB
              ① Check Fridge Door Wiring - Short or Open Wire
              ② Check CABI Upper Wiring - Short or Open Wire
              ③ Check Short/Open at MAIN PCB Panel Lamp Circuit
                                                                     No
                                            The LED Lamp is ok
Normal
                                             69
 TROUBLESHOOTING
4-2-10. When Ice Maker does not operate (Model with Ice Maker)
      1. Water supplies to the Ice Maker automatically and ice is to be twisted out depending on its temperature and
        the timing.
      2. Power is always applied to the Ice Maker. So, refer to the disassembly section to remove it.
      3. To check the operation of the Ice Maker, press the Ice Maker Test Switch before disassembling it.
        It is not possible to check its operation after disconnecting its power.
ERROR CODE
Start
                                                                        70
TROUBLESHOOTING
  Protecting
                          LED Blinking Frequency                                   Remark
  Functions
   Normal
                                                                                     N/A
  Operation
   Starting
   Failure                                                   1. Short between COMP U,V, and W phase (CN102)
                                                             2. Short among IC3 Pins (No. #1~24)
                                                             3. Drop the IPM operating Voltage under DC 13.5V
                                                             4. Other cases, check the COMP, cycle, etc.
   IPM Fault
                                                             1. D
                                                                 rop the input voltage under AC106V. Short
 Low Voltage
                                                               resistor R514 (DC link resistor)
LED blinking frequency depending on protecting functions If the same blinking, After 5 minutes, Follow the
Remarks
71