H060 Laboratory Cooling Plant With Ice Store: P.A. Hilton LTD

The document describes the H060 Laboratory Cooling Plant, which consists of two insulated tanks, pumps, and instrumentation that allow investigation of batch and continuous heating and cooling processes. It can be connected to the Hilton Air and Water Heat Pump (R832) and Bench Top Cooling Tower (H892) to compare dry and evaporative cooling. The system provides flexibility to use the components individually or connected to study refrigeration, air conditioning, and other thermal processes.

Uploaded by

Manoj Khatri
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
154 views4 pages

H060 Laboratory Cooling Plant With Ice Store: P.A. Hilton LTD

The document describes the H060 Laboratory Cooling Plant, which consists of two insulated tanks, pumps, and instrumentation that allow investigation of batch and continuous heating and cooling processes. It can be connected to the Hilton Air and Water Heat Pump (R832) and Bench Top Cooling Tower (H892) to compare dry and evaporative cooling. The system provides flexibility to use the components individually or connected to study refrigeration, air conditioning, and other thermal processes.

Uploaded by

Manoj Khatri
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

P.A.

Hilton Ltd

H060 Laboratory Cooling Plant


With Ice Store
Figure 1: H060 shown with H892 and R832

Compare Dry Cooling with Evaporative Cooling Using


Hilton Bench Top Cooling Tower H892

Investigate Flow and Batch Processes Using Hilton Air and


Water Heat Pump R832

Can be used in isolation or connected together

Optional Computerised Data Acquisition Upgrade HC060A

Two years warranty

Page 1 of 4
P.A. Hilton Ltd

Introduction
In many industrial processes such as air conditioning or power generation a cooling tower is used to
reject heat from the system. A reservoir may be used in these, or other processes to provide either a hot
or cold store for an industrial process that has varying load.

To investigate these processes the Hilton Air and Water Heat Pump R832 may be linked to the Hilton
Bench Top Cooling Tower H892 using the Hilton Reservoir System H060.

The Reservoir System H060 has a heat load and instrumentation, pumps, tanks, thermocouples and
flow measurement to allow both batch and flow heating and cooling processes to be investigated

The units carrying out heating and cooling processes (R832 or H892) may all be used to their full
specification either attached to the Reservoir System H060 or in their standard configuration in
isolation. This gives complete flexibility and maximum equipment utilisation.

The unit will be of particular interest to those studying:

• Refrigeration and Air Conditioning


• Building Services
• Chemical Engineering
• Energy Transfer and Conservation
• Mechanical Engineering
• Plant and Process Engineering

Experimental Capabilities
Reservoir System H060 with Air and Water Heat Pump R832 Only.
• Demonstration of a batch cooling and batch heating process using a vapour compression
refrigeration system.
• Demonstration of continuous flow heating and cooling process using an air-water heat
exchanger and a heat pump as the heat load.
• Thermodynamic investigation of a vapour compression air and water heat pump including full
cycle pressure-enthalpy diagram, performance curves using an air and water heat source and
individual component energy balances.
• Optional Computerised Data Acquisition available.
Reservoir System H060 with Air and Water Heat Pump R832 and Bench Top Cooling Tower
H892. Allows all of the above experiments together with:
• Comparison of dry cooling performance with evaporative cooling under the same load
conditions.
• Investigation of the performance of a forced draught evaporative cooling tower under varying
load conditions and with variable air and water flow rates. Operation to the full specification
of the Bench Top Cooling Tower H892.
• Optional additional columns available refer to H892 literature.
• Optional Computerised Data Acquisition available.

Page 2 of 4
P.A. Hilton Ltd

Description
The Laboratory Cooling Plant With Ice Store H060 has been designed to allow investigation of
both batch and flow heating and cooling processes.

The Reservoir System H060 comprises two insulated tanks mounted on a base with a central control
panel and dry cooling heat exchanger. Three high capacity circulating pumps and the necessary hoses
allow connection to three alternative Hilton units.

Utilising the Hilton Air and Water Heat Pump R832 the water evaporator is selected and this is
connected through hoses supplied to a coiled heat exchanger inside the Cold Reservoir. One of the
H060 circulating pumps provides a flow of water/glycol through the evaporator and heat exchanger
thereby cooling the water inside the Cold Reservoir. With suitable flow rate the water inside the Cold
Reservoir will form an ice bank around the heat exchanger. The Cold Reservoir is fitted with a heater
that may be controlled and its heat input measured using the wattmeter on the control panel.

The Hot Reservoir provides a source of water circulated by a second pump through the condenser of the
Air and Water Heat Pump R832 this raises the temperature of the water in the Hot Reservoir.
A third pump circulates the water in the Hot Reservoir through the Dry cooling Heat Exchanger.

All of the pumps and heat load may be operated from the Control Panel and the flow rates varied using
the original flow meters on the R832 unit.The flow through the Dry Cooling Heat Exchanger is
controlled and measured by the flow meter on the H060 unit.

With the addition of the Bench Top Cooling Tower H892 self sealing couplings allow the H892 to
replace the role of the Dry Cooling Heat Exchanger. As the H892 unit carries out evaporative cooling
the water can be cooled closer to the ambient wet bulb temperature and the performance relative to the
Dry Cooling Heat Exchanger may be investigated under identical load conditions.

The Control Panel includes a digital temperature indicator and selector switch to allow indication of all
relevant system temperatures.

Each of the Hilton units coupled to the Reservoir System H060 may be disconnecetd and operated in
isolation according to their full normal specification. This gives complete system flexibility and
maximises equipment utilisation.

The addition of the Reservoir System H060 to the Air and Water Heat Pump R832 and Bench Top
Cooling Tower H892 means that the requirement for a water supply and drain is removed and only a
power supply is necessary for operation of all three units.

Page 3 of 4
P.A. Hilton Ltd

Specification
General
A two reservoir pump and tank system with heat Services Required
load and control console that allows investigation of Electrical: A: 1.3 kW. 220-240 Volts, Single
batch and flow heating and cooling processes (with Phase 50Hz (With
the addition of a suitable vapour compression heat earth/ground).
pump and bench top cooling tower).
Both the heat pump and cooling tower may be Or: 1.3kW.110-120 Volts, Single
disconnected as required and operated in isolation Phase 60Hz (With
or coupled to the pump and tank system. The pump earth/ground).
and tank system incorporates a dry cooling heat
exchanger and instrumentation to record the flow
rate and relevant system temperatures. Ordering Information
Order as: H060 Laboratory Cooling Plant
Detailed
A bench mounted system with hot reservoir, cold Optional: HC060A Data Acquisition
reservoir, dry cooling heat exchanger and three Upgrade
circulating pumps suitable for connection to the
Hilton Air and Water Heat Pump R832 and Bench Electrical Specification
Top Cooling Tower H892. Either: A: 220-240 Volts, Single Phase
An integral control console allows control and 50Hz (With earth/ground).
measurement of the heat load in the cold reservoir
and measurement of all relevant system B: 110-120 Volts, Single Phase
temperatures. 60Hz (With earth/ground).
Instrumentation:
A digital Temperature indicator with channel
selector switch for all relevant system temperatures.
Duplex thermocouples for optional computerised Shipping Specifications
data acquisition. Variable area water flow meter Net Weight: 70 kg.
with flow transducer for dry cooling flow Approximate Gross Weight: 117 kg.
measurement. Approximate Packing Case Dimensions:
Safety 1.46 x 0.75 x 0.65m
All electrical circuits have combined miniature Approximate Packing Case Volume:
circuit breakers and overload cut outs. 0.712m3
Residual current circuit breaker for operator
protection.
Also Available On Request
Further detailed specification.
Heat load in the cold reservoir protected by high
Additional copies of instruction manual.
temperature cut out switch.
Recommended list of spares for 5 years operation.

Dimensions
Height: 450mm P A Hilton Ltd.
Depth: 650mm Horsebridge Mill, King’s Somborne,
Stockbridge, Hampshire, SO20 6PX, England.
Width: 1300mm
Weight 70kg Telephone: National (01794) 388382
International +44 1794 388382
Fax: (01794) 388129
E-mail sales@p-a-hilton.co.uk

Accessories and Spares


Unit supplied with:
One experimental operating and maintenance
manual
Accessories and spares for 2 years normal
operation. List available on request.

You might also like