Torque Sensor Position Sensor Battery S1 S2 S3 S4: Tap Nominal 50/60Hz W 220/230 X 380/400 Y 400,415/420 Z 440/460 Type 1

This document provides a summary of a circuit diagram with details for a remote control power supply and transformer tapping options. It includes information on transistor switching for 24VDC contactors, fuse types and ratings, monitor relay connections, torque and position sensor connections, and remote/local control connections. Refer to sheet 2 for additional notes and option PCBs if fitted.

Uploaded by

alfredo.mqi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views2 pages

Torque Sensor Position Sensor Battery S1 S2 S3 S4: Tap Nominal 50/60Hz W 220/230 X 380/400 Y 400,415/420 Z 440/460 Type 1

This document provides a summary of a circuit diagram with details for a remote control power supply and transformer tapping options. It includes information on transistor switching for 24VDC contactors, fuse types and ratings, monitor relay connections, torque and position sensor connections, and remote/local control connections. Refer to sheet 2 for additional notes and option PCBs if fitted.

Uploaded by

alfredo.mqi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

W

CIRCUIT DRAWN WITH POWER SUPPLY OFF FOR TYPICAL REMOTE CONTROL
M 2
2 DETAILS, SEE DOCUMENT
3
3 V
4
1
3
PHASE
RWS102
SUPPLY
U
3 1 TR AN S F OR ME R TAP P IN G OP TION S
6

5 T ap Nominal 50/60Hz
U V W E TYP E 1
FS1
W 220/230
X 380/400
C1 C2 Y 400,415/420
U W X Y Z
Z 440/460
F US E F S 1= 250mA A NTI-S UR G E
SK2 TYP E 2
0VAC 1 W 346/380
TRANSISTOR SWITCHING FOR
PS1 X 480/500
24VDC CONTACTORS (IQ10-35) 120VAC 4
RELAYS ONLY FITTED WHEN Y 240/240
0VDC
120VAC CONTACTOR IS FITTED 3 4 Z 550/575
24VDC
FOR IQ40,70,90,91 & 95 24VDC 6 F US E F S 1= 250mA A NTI-S UR G E
_ 5 NOMINAL SUPPLY

+
(OUTPUT)
TYP E 3
SK14
X 660/660-690
0VDC 1
INTERNAL SUPPLY Y 690/-
24VDC FOLO / CPT PCB F US E F S 1= 150mA A NTI-S UR G E
2
SK13

26 WAY
REFER TO SHEET 2 FOR NOTES
& OPTION PCB'S IF FITTED

SK3 SK13 SK14


6 1 42
MONITOR RELAY
5 3 43
TORQUE 4 2 44
3
2
SK7
SENSOR 1 1 6
SK8 MAKE AT FULLY SHUT S1 8 7
POSITION 10 WAY 2 8
SENSOR MAKE AT FULLY OPEN S2 7 9
SK9 BREAK AT FULLY SHUT
3 10
BATTERY - 4
S3 6 11
4 12
+
1 BREAK AT FULLY OPEN S4 5 13
FS2 (IF FITTED) 100mA SK4
CLOSE 9 33
STOP/ MAINTAIN 10 34
50% SK6 OPEN 8 35
COMMON -VE 1 36
18 WAY
REMOTE
ESD 12 25
CLOSED
STOP

OPEN LOCAL
OPEN INTERLOCK 13 37
CLOSE INTERLOCK 14 38
COMMON -VE 5 31
SK1 SK2
SLOT A SLOT B

Iss Date Chkd Revision Details IQ + FOLOMATIC + CPT


4 031012 PMJ NOTE 2 UPDATED. www. .com
5 090113 PMJ Re-track of the 24V DC pin
ROTORK CONTROLS LTD ROTORK CONTROLS INC Drawn by: PMJ Circuit Diagram Number Issue Sheet
on SK14 to behind the diode Date : 160512 No
BATH, BA1 3JQ ROCHESTER
6 160614 MR 400v added to type 1
tapping Y. Note added to
ENGLAND NY 14624, USA
Base WD: 103B0000
Job No : - -
103B0000 6
1
of 2
sheet 2 note 1. Tel:01225-733200 Tel:585-247-2304 MI No : - - B1 C1 B2 C2
IQ3
CIRCUIT DRAWN WITH POWER SUPPLY OFF

SLOT A
SK1
SLOT A SK3
-VE +VE
1 23 A
2 22
DEMAND +VE 3 26
COMMON -VE 4 27 } ANALOGUE INPUT SIGNAL
FOR FOLOMATIC
FOLOMATIC /

NO CONNECT 5
CPT

MANUAL/AUTO 6 39
COMMON -VE 24VDC 7 41
COMMON -VE 120VAC 8 45
SK6
1 0V
2 24V
SUPPLY FROM SK14 ON POWER PCB
SK8
1
2

FOR MANUAL/AUTO CONNECTIONS AND


DETAILS OF FOLOMATIC/CPT FUNCTIONS
REFER TO ROTORK PUBLICATION PUB002-041

NOTES
1.FUSES:
-PS1 is a self-resetting fuse. 3.INDICATION:
-Refer to publication PUB002-039 for approved fuses FS1 and FS2. -For typical position, status and alarm indication see PUB002-041.
-Actuator rated voltage specified on nameplate. Voltage tolerance +/-10%, -“S” contacts are user configurable and are shown in their default
applies for rated torque performance; duty cycle is not guaranteed. setting.
2.REMOTE CONTROL: -Refer to PUB002-040 for functions and configuration instructions.
-For typical remote control circuits refer to: -Monitor Relay indicates actuator availability for remote control (shown
-RWS indicated or PUB002-041. “unavailable”). It can be configured to exclude local/remote selection.
-For DC and AC control, connect –ve/0V to terminal 36. -Refer to PUB002-040 for monitored functions and configuration
-(For negative switch / positive common, refer to RWS indicated). instructions.
-Control signal threshold voltages: -Voltage applied to indication contacts must not exceed 150Vac
-DC: “on” ≥16Vdc / “off” ≤8Vdc, max 60Vdc. -Individual Switch current must not exceed 3.5A inductive, 5A resistive
-AC: “on” ≥60Vac / “off” ≤40Vac, max 120Vac. and no more than 8A in total for all 4 contacts.
-Control signal duration to be 300ms minimum.
-Maximum current drawn from remote control signals is: 4.BATTERY:
-8mA at 24Vdc or 12mA at 120Vac. -Battery maintains local and remote “S” contact indication only.
-Supply provided on terminals 4 & 5: -Refer to installation manual for approved replacement battery types.
-Intended for remote control. Circuit Diagram Number Issue Sheet
-Max external load 5W at 24Vdc / 5VA at 120Vac No
103B0000 6 2
See Sheet 1 for all Revision details/information of 2
IQ3

You might also like