PT PROFAB INDONESIA STANDARD FLANGE FOR KAOMBO PROJEC Page 1
JN1201 Spectackle Blind Calculation
For Hydrotest Condition Test Pressure 26 Barg
Based on ASME B31.3
Spectackle 1" 150 #
Test Pressure TP 1.65 MPa = 16.5 barg
Corrosion Allowance C 0.00
Material of blind A36 or equivalent
Spacer Thickness 20.00 mm
Applicable Allowable stres S 1400.00 Kg/cm2
(From Table A-1)
Calculation Based ASME B31.3 304.5.3
T min = Required Thickness
= B1*SQRT*(3*P/(16S))+C
PIPE ID (B1) PIPE INSIDE THK
PIPE SIZE
(MM) ( RADIUS) (ASME )
1" 699 349.5 32.86
Status t<tmin Thickness Insufficient
PT PROFAB INDONESIA STANDARD FLANGE FOR KAOMBO PROJEC Page 1
JN1201 Spectackle Blind Calculation
For Hydrotest Condition Test Pressure 26 Barg
Based on ASME B31.3
Spectackle 2" 150 #
Test Pressure TP 2.60 MPa = 26 barg
Corrosion Allowance C 0.00
Material of blind A36 or equivalent
Spacer Thickness 16.00 mm
Applicable Allowable stres S 1351.00 Kg/cm2
(From Table A-1)
Calculation Based ASME B31.3 304.5.3
T min = Required Thickness
= B1*SQRT*(3*P/(16S))+C
PIPE ID (B1) PIPE INSIDE THK
PIPE SIZE
(MM) ( RADIUS) (ASME )
2" 52.5 26.25 3.15
Status t>tmin Thickness Sufficient