Low Voltage VT & AVR & CT & PT
Automatic AC Voltage Regulators
                                                                 2. Type designation
                                                                 TN□1 -□/□
                                                                              Cooling type. AN means: convective cooling
                                                                              (AN will be omitted in model description);
                                                                              AF means: draw out the hot-air with fan or
                                                                              blow on the product direct.
                                                                          Rated capacity of regulator (kVA)
                                                                       Design serial number
                                                                      D: single-phase, S: three-phase
                                                                   Automatic voltage regulator
                                                                   (high precise automatic AC voltage regulator)
     TND1 Single-phase Automatic
     AC Voltage Regulator
     TNS1 Three-phase Automatic
     AC Voltage Regulator                                        3. Operating conditions
     1. General                                                  3.1 Ambient temperature: -5℃~+40℃.
     1.1 Application:                                            3.2 Relative humidity ≤90%(at +20℃).
         TND1/TNS1 series full-automatic AC voltage              3.3 Altitude: ≤2000m.
         regulator collects sample and amplifies it              3.4 Working environment: Indoors,
         and automaticly control circuit, and drives the             be free from chemical deposition, dirt,
         servomotor to rotate the rocker arm and brush in            harmful corrosive medium, or flammable or explosive gas.
         required direction, and finally adjusts the output
         voltage to the rated value,
         finally reaches the aim of stabilizing the voltage.
         It can be widely used in areas,
         where the mains voltage often comes across sharp
         fluctuation or sharp seasonal variation,
         such as industrial production, scientific research
         medical treatment & hygiene,
         household electrical appliances,
         it can provide any loads with excellent power supply.
     1.2 Features: Elegant appearance, compact structure,
         light weight, low power waste,
         complete protection functions, stable and reliable,
         low output waveform distortion and so on.
11   >>   Empower the World
Low Voltage VT & AVR & CT & PT
Automatic AC Voltage Regulators
4. Technical data
   Model                                                         TND1                                                          TNS1
   No. of phase                                                  single                                                        three
   Input voltage (V)                                          160V~250V                                        280V~430V(3-phase, 4-lines)
   Output voltage (V)                                         220V±4%                                           380V±4%(3-phase, 4-lines)
   Frequency (Hz)                                                                           50-60
   Adjusting time(s)                                             ≤3s when the input voltage changes within the range of 20V
   harmonic distortion                                                            No additional distortion
   Output over-voltage protection setting value                246±4V              Phase voltage 246±4V
   Output under-voltage protection setting value               180±8V              Phase voltage 180±8V
5. Features
5.1 Output capacity                                                                                                                                  Fig. 1
                                                                                             P————— Outp ut capacity
    The relation between output capacity and input voltage                           P/Pe    Pe———— Rate d o utp ut capacity
    refer to as fig. 1
    When input voltage less than 198V, the output capacity of product         100%
    will decrease, the working capacity of stabilizer shall come down;
    when you choose output voltage of 110V, the out put capacity
    shall be not more than 60% rated capacity,to prevent overload.             60%
5.2 Overload capacity
    The stabilizer is not allowed for working overloading long time,
    when the input phase voltage fluctuate                                                                                      In put vo ltag e V
    within 198V ~ 250V (line voltage from 342V ~ 430V),                            160        198                   250         Phase volta ge
    at emergent case, it is allowed towork as specified in sheet 1.                280        342                   430         Time volta ge
                                                                                                                               Empower the World     >>   12
                                                                                              Low Voltage VT & AVR & CT & PT
                                                                         Automatic AC Voltage Regulators
6. Overall dimensions and weights
     Phase                                                                                                     Weight           Gross
                       Model & Spec.       Overall dimensions (mm)       Packing dimensions (mm)     Pcs
     number                                                                                                     (kg)          weight (kg)
                          TND1-0.5             195×205×150                   235×215×175              1          4.5              4.8
                           TND1-1              215×240×170                   260×250×200              1          6.1              6.5
                          TND1-1.5             215×240×170                   260×250×200              1          6.5               7
                           TND1-2              225×290×220                   330×260×260              1          8.5               9
     Single-               TND1-3              245×305×240                   360×300×270              1          12.5             13
     phase                 TND1-5              225×350×285                   385×265×310              1          16.5             17
                    TND1-10/AF(vertical)       285×320×520                   390×410×610              1          38.5             47
                    TND1-10(horizontal)        245×430×375                   310×475×410              1           33              35.5
                         TND1-15/AF            325×430×620                   415×550×720              1          58.5             68.5
                         TND1-20/AF            325×430×620                   415×550×720              1          71.5             81.5
                         TND1-30/AF            402×735×803                   510×830×965              1          140              156
                          TNS1-1.5             490×325×160                   525×375×200              1           16              16.5
                           TNS1-3              490×325×160                   525×375×200              1          19.5             20
                          TNS1-4.5             490×325×160                   525×375×200              1          21.5             22
                           TNS1-6              275×355×620                   335×405×680              1          33.5             37
     Three-                TNS1-9              330×360×730                   385×410×780              1           46              50
     phase                 TNS1-15             330×420×840                   415×550×930              1          60.5             66
                           TNS1-20             480×465×930                  590×580×1020              1          110              126
                         TNS1-30/AF            480×465×930                  590×580×1020              1          115              131
                         TNS1-45/AF           480×790×1055                  600×850×1200              1          191              213
                         TNS1-60/AF           480×790×1055                  600×850×1200              1          230              250
7. Ordering information
     a. Input and output of three-phase products of this series are of three-phase four-wire connected,
       please wire them with neutral line before using.
       Example of type selection: Three-phase motor 2.2kW 1pcs, 5.5kW 1pcs, when selecting the voltage regulator,
       its capacity should be ≥(2.2kW+5.5kW)×2.5=19.25kVA, so,
       the selected product should be three-phase SVC-20kVA at least.
     b. When the three-phase voltage regalator is applied to single-phase or three-phase ,
        max capacity of each phase should be one third of rated capacity.
     c. When the input phase voltage is lower than 198V, the output capacity of voltage regulator will be reduced,
        then the loads should be reduced correspondingly, otherwise, it may be overloaded; when the output voltage is 110V,
        then the output capacity should not be beyond 50% of rated capacity, otherwise, it may be overloaded.
        Please refer to fig.1 for detail characters.
Sheet 1 Safe consult coefficient of choosing regulator capacity
     Load kind                                Consumer samples             Safe coefficient               Chosen capacity rate
                                               Incandescent lamp,
                                                                                                           >1.1~1.3 times of
     Complete resistive loads                 resistant coil, electric         1.1~1.3
                                                                                                           total rated capacity
                                                      cooker
                                             Fluorescent lamp, fan,
                                                                                                            >2.5~3 times of
     Inductive, capacitive loads             pump, air-conditioner,             2.5~3
                                                                                                           total rated capacity
                                              refrigerator and etc.
13   >>   Empower the World