UT Level II
UT Level II
Introduction
Introduction Introduction
                                                                                                                                       1
                                                                                                                                                                                     4/2/2021
             Applications
                                                                                                     Measures depth and through-wall Extent           Single-sided access is sufficient
    Welds             Composites
       No permanent record (unless automated)                                                    Ultrasonic waves are introduced into a material
                                                                                                  where they travel in a straight line and at a
                                                                                                  constant speed until they encounter a reflector.
       Skill and training is more extensive than with some other methods.
                                                                                                                                                                                           2
                                                                                                                                                            4/2/2021
                                     The sound reflected back to the probe is                                                    Signal from the backwall
                                        displayed on the Flaw Detector
Bottom / Backwall
60 mm
Defect
                                                                                                                                                                  3
                                                                                                                                  4/2/2021
                                                                                                               Oscillation
                    Pulse
         The ball starts to oscillate as soon as it is pushed
                                                                                                                                        4
                                                                                                                                             4/2/2021
    • Low density           • Medium density   • High density                  Ball = atom               Spring = elastic bonding force
    • Weak bonding forces   • Medium bonding   • Strong bonding forces
                              forces           • Crystallographic
                                                 structure
                                                                                                                                                   5
                                                                                                    4/2/2021
Distance travelled
                                                                             V = Speed
                                                                             T = Time Period
                                                                             λ = Wave Length
                                                                             (Distance Travelled)
                                                                                                          6
                                                                                                                        4/2/2021
                                            Elastic
                                           Modulus
                                                                                                    Constant Velocity
                               Materials
                               Density                                         Frequency
                                                  Velocity of
                                                                                                  Changing Wavelength
                                                    Sound
5 M Hz
                                                      STEEL
                                                                                     WATER                AIR
                                                                                                                              7
                                                                                  4/2/2021
Sensitivity                          Resolution
                 Resolution is the ability of an equipment / combination probe
                  to distinguish between two echoes from reflectors that are
                  close together.
                 To have good resolution a probe must present two signals on
                  a CRT screen from two separate reflectors.
                 If it has poor resolution the echoes from the two reflectors
                  appear as one signal on the screen.
                                                                                        8
                                                                                                                                  4/2/2021
 6dB difference means that one signal is 2 times bigger than another.
 10dB difference means that one signal is 3 times bigger than another.
                                                                           1 M Hz          5 M Hz         10 M Hz       25 M Hz
 12dB difference means that one signal is 4 times bigger than another. LONGEST  = v/f SMALLEST
20dB difference means that one signal is 10 times bigger than another.         F                        F         
                                                                                    Which probe has the smallest wavelength?
                                                                                    Which probe has the longest wavelength?
                                                                                                                                        9
                                                                                 4/2/2021
                                                                                      10
                                                                                                                          4/2/2021
                                                                                                                               11
                                                                                                            4/2/2021
                           Direction of propagation
Direction of Oscillation
                                                                                                                 12
                                                                                              4/2/2021
Same material
                                                                                                   13
                                                                                                                             4/2/2021
                                                                                                                                  14
                                                                                                                          4/2/2021
                                                                                                                    AC
                                           +
                                                                                                                               15
                                                                                                                                          4/2/2021
                                                                                                                                               16
                                                                                                                                       4/2/2021
                                                                                                                                            17
                                                                                                                                              4/2/2021
                                                                        Disadvantages:
    Unsuitable for
    Industrial use
                                                                            Its curie point, at which the crystal depolarize is about only
                                                                             115-150oC, so heating ruins it.
                                                                            It deteriorates over a period of time.
                                                                                                                                                   18
                                                                                                                                      4/2/2021
Advantages: Advantages:
                                                                                                                                           19
                                                                                                                                             4/2/2021
                                                                                                                                                  20
                                                                                                                                       4/2/2021
                                                                                                                                            21
                                                                                                    4/2/2021
                                            Short Pulse
                            Long Pulse
                                                                     Normal Pulse
                                                                                                         22
                                                                                                                                                 4/2/2021
6
D0
                                                                                                                                                      23
                                                                                                                 4/2/2021
             Diameter
            Frequency       Near zone
             Velocity
Far Field (Zone): Beam Spread                     Far Field (Zone): Beam Spread
                                                                                       I=0%
                                                                                                       I=10%
               Half Beam Spread Angle
                                                                                                            I=50%
I= maximum (100%)
                                                                                                                       24
                                                                    4/2/2021
 Frequency
                 Beam Spread
Velocity
1 2 3 4
                                                                         25
                                                                                                                             4/2/2021
                  Attenuation                                                Absorption
                                                         Resulting from transformation of ultrasonic energy into other
Decrease of sound intensity (pressure) when a wave        types of energy (e.g. thermal).
travels through a material arising from:                 Occurs as the sound pulse hits the molecules of the test
    Absorption (Material)                                material and makes them vibrate.
                                                         The energy lost in vibrating the molecules turns to heat.
    Scattering (Material)
                                                         The rate of absorption varies from one material to another and
                                                          even from one type of steel to another.
    Beam Spread (Far Field)
                                                         It is high in soft materials (e.g. Perspex, nylon & lead) and is
                                                          low in aluminum.
                                                                                                                                  26
                                                                                                                   4/2/2021
                       Scattering                                               Scattering
   Randomly reflected energy caused by grain structure and/or
    by small discontinuities in the beam path.
   The larger the grain size (course grain structure), the more
    scatter occurs.
                                                                                   Cast Product
   When grain size ≈ λ/10, Scattering is high.                                                       Scattering
                                                                                  (Cast Iron/Brass)
   Grass/Hash/Noise exist on CRT due to course grain structure.
                                                                                  Wrought Product
                Wavelength          Scattering                                                        Scattering
                                                                                  (Refined steel)
Frequency Penetration
                                                Where:
                                                I = Intensity of sound
                                                beam.
                                                d= Distance.
                                                                                                                        27
                                                                                                   4/2/2021
                                                                                                        28
                                                                                                                                            4/2/2021
                                                                                                                                                 29
                                                                                                              4/2/2021
At Normal Incidence
Medium 1
                                          Interface
                                                                                      Medium 2
R=
                                                                             T=1-R
                                            R=                               So,
                                                                             T= 1-0.88=.12x100= 12%
                                            R=
R=
                                                                                                                   30
                                                                                                                                    4/2/2021
Reflection
Snell Law & Mode Conversion Snell Law & Mode Conversion
          Is that
          Refraction?
NO
                                                                                                                                         31
                                                                                                                                      4/2/2021
Snell Law & Mode Conversion Snell Law & Mode Conversion
 Mode Conversion
                                                                   Critical Angle
  When sound waves pass obliquely (not at 90o) between materials
  having different acoustic velocities, one mode of wave energy    There are two critical angles:
  can be transformed into another mode on passing through the
  interface and the sound wave is said to have been mode           First Critical Angle:
  converted.                                                       The incident angle at which a refracted compression wave in the
Is that                                                            test material is generated at 900.
Mode
                                                                    Second Critical Angle:
conversion?
                                                                    The incident angle at which a refracted shear wave is generated
                                                                    in the material at 900.
NO
Snell Law & Mode Conversion Snell Law & Mode Conversion
                                                                                                                                           32
                                                                                                    4/2/2021
Snell Law & Mode Conversion Snell Law & Mode Conversion
Transducer
Contact Immersion
                                                                               Compression
                                               Normal             Angle Beam
                                            (Compression)           (Shear)     (Shear by
But answer is not correct:                                                     Angulation)
Use Vs= 3250      Correct Answer R= 17.80
                                                                                                          33
                                                                                                                                      4/2/2021
Angle Beam Type Some times called Normal Probes or Straight Beam Probes.
                                                                         Single
                                                                         Crystal
                                                                                                                                           34
                                                                                                                                           4/2/2021
Calculate the cut angle in perspex wedge to have the 450 shear           Transmits and receives ultrasound with one crystal:
beam refracted angle in steel?
    Vp=2730 m/s
    VS= 3250 m/s
    R=450
Answer I= 36.40
   Signal appears on the screen at the beginning of the time base,                      Length of the initial pulse is the dead zone.
                                                                                         Signal from near surface reflector will be
    named as initial pulse, transmission signal, crystal strike or                       merged in initial pulse & will be undetectable.
    main bang.
      IP                             IP
                                      Initial Pulse
                                                      B
                                                       BWE
      F                                 F
                                          Flaw Echo
                                                                                                                                                35
                                                                                                                                        4/2/2021
Disadvantages                                                            Used in immersion technique where test part and probe are
    Good contact is difficult with curved surfaces.                      immersed in water.
    Difficult to size small defects accurately as the width of a        Squirter or bubbler system are variation of immersion test:
     double crystal probe is usually greater than that of a single       Have impedance matching layer that helps to get more sound
     crystal probe.                                                       energy into the water and in turn, into the component being
    The amplitude of a signal decreases if a reflector is situated       inspected.
     away from the focal distance.                                       Available in a flat, cylindrically or spherically focused lens.
    Cross talk.                                                         A focused transducer can improve sensitivity and axial
                                                                          resolution by concentrating the sound energy to a smaller area.
                            Therefore
                                                                         These are high frequency probes.
       Single and twin crystal probes are complementary to
                            each other
                                                                                                                                             36
                                                              4/2/2021
                                                                   37
                                                                                                                                                     4/2/2021
Through Transmission IP
                                                                                                                                   BE
Tandem Scanning
Contact Scanning
                                                                                                                           F
Gap Scanning
                                                                                          delamination        0        2       4        6   8   10
Immersion Testing                                                     plate
                                                                                                                       IP = Initial pulse
                                                                                                                       F = Flaw
                                                                                                                       BE = Backwall echo
                                                                                                                                                          38
                                                                                                                                       4/2/2021
Flaw Signal
                                                                                                                                            39
                                                                                                                           4/2/2021
                                                                                                                                40
                                                                                                                                                4/2/2021
                                  BE                          BE
                                                          F
0 2 4 6 8 10 0 2 4 6 8 10
                                                                                                                                                     41
                                                                                                                                             4/2/2021
                                                                                                                                                  42
                                                                                                                                           4/2/2021
                     Presentation                                                          Presentation
                                                                           A-Scan                  B-Scan                   C-Scan
   The flaw detector or UT set sends ultrasound energy into test
    materials and some of this returns to the set to be presented as
    information on a CRT screen.
   Following are the scan display:
    •   A Scan Display
    •   B Scan Display
    •   C Scan Display
    •   D Scan Display
                     Presentation                                                          Presentation
A Scan Display:                                                        B Scan Display:
   Amplitude of signals displayed as a function of time or               Gives an end or cross-sectional view of the component being
    distance.                                                              examined with the position of the probe displayed on one axis
                                                                           and the distance from the surface to the signal on the other.
                                                                          Used in immersion testing with an automated scanning device.
                                                                                                                                                43
                                                                                                                                           4/2/2021
                     Presentation                                                            Presentation
C Scan Display:                                                         D Scan Display:
   C scan gives a plan view of a defect.                                  The D scan gives a side view of the defect seen from a
   Used as an automated process to map out laminations in plate.           viewpoint normal to the B scan.
   Gives the area of a defect, so it is good for plotting the extent      It is usually automated and shows the length & depth of the
    of laminations in sheets.                                               defect.
                                                                                                                                                44
                                                                                                                                           4/2/2021
                                                                                                                                                45
                                                                                                                                               4/2/2021
 Rectifier
 Attenuator
                                                                                                                                                    46
                                                                                                                                       4/2/2021
   Comparing the height of one signal with the height of                                                             Amplified (RF)
                                                                             Received from Probe
    another.
   Two information's retrieved :
   Should be in off
position in accordance
    with ASME V.
                                                                                                                                            47
                                                                                                                           4/2/2021
                                                    Particularly suitable for short near field lengths and the time base
                                                    calibration of small diameter normal and angle probes.
                                                                                                                                48
                                                                                                        4/2/2021
                                                                                                             49
                                                                                                                    4/2/2021
                                                                                                                          50
                                                                                                                   4/2/2021
                                                                                                                        51
                                                                                                                                         4/2/2021
                                                                                                     Beam Path/Metal
       θ                                                                                             Path
                                                                                                                                              52
                                                                                                                                      4/2/2021
                                                                                        Flaw Sizing
                                                                   6dB Drop Method:
Flaw Sizing
                                                                                                                                           53
                                                                                                                                            4/2/2021
                                                                                                                                                 54
                                                                                                                                          4/2/2021
10%FSH 10%FSH
                                                                                                                                               55
                                                                                                                                        4/2/2021
10%FSH
                                                                                                                                             56
                                                                                                                                     4/2/2021
                                                                              Sensitivity Setting
                                                                 Setting a sensitivity level is essential to provide reproducible
                                                                  results from the same inspection carried out by different
                                                                  operators using different probe set combinations and maybe
            Sensitivity Setting                                   working in different locations.
          (Pre Reference Level)                                  The purpose of sensitivity setting is to find a gain level
                                                                  sufficient to find a flaw.
                                                                 Sensitivity depends on the:
                                                                  •   Probe used, in particular its frequency.
                                                                  •   Flaw detector.
                                                                  •   Properties of the test material.
                                                                  •   Ratio of BWE or flaw echo to noise.
                                                                                                                                          57
                                                                                                              4/2/2021
                                                                                                                   58
                                                                                                                                           4/2/2021
                                                                                                                                                59
                                                                                                                                             4/2/2021
                                                                                                                                                  60
                                                                                                                                             4/2/2021
                                                                                                                                                  61
                                                                                             4/2/2021
              Practice Problem
5. Gain difference between the flaw echo and BWE at 60mm is
(30-16=14dB).
6. Look down the scale 14dB at 3N from the BWE which is                    ≈14+6
equal to 20 dB and found the corresponding curve with 0.3                  =20 dB
approximately.
7. Multiply the 0.3 with probe diameter.
8- R= 0.3X10mm = 3mm.
                                                              (For NP)
                                                                                      ≈0.3
                                                                                                  62
                                                                                                                                                4/2/2021
       Allowance for the differences in sound energy transfer between      Angle Probe Method:
        test material and reference block with same equipment is               Place the two probes opposite each other on the reference
        known as Transfer correction.                                           block with one probe transmitting and the other receiving, so
                                                                                that the sound energy is bounced off the backwall and caught
Normal Probe Method:
                                                                                by the receiving probe (pitch and catch).
        Place the probe on the reference block and turn the BWE up
                                                                               Maximise the signal and adjust the gain until it is at FSH.
         to FSH. Note the gain settings.
                                                                               Place the two probes on a piece of test material of the same
        Now place the probe on the test material and at a similar
                                                                                thickness as the reference block and repeat the process.
         range bring the BWE to FSH. Again note the gain setting.
                                                                               Note the difference between the two gain settings.
        The difference between them is the transfer correction.
                                                                               This is the transfer correction needed.
                                                                                                                                                     63
                                                                                                                                       4/2/2021
                                                                                                                                            64
                                                                                                                                   4/2/2021
 Beam Angle
 Penetration Power
                                                                                                                                        65
                                                                                                                                              4/2/2021
In Accordance With ASME V (Article 4):                                   In Accordance With ASME V (Article 4):
   Position an angle beam search unit on a calibration block.              Alternate: A straight beam
   Obtain indications from both the 1/2T and 3/4T holes give a              search unit may be used on
    2:1 ratio of amplitudes between the two indications.                     any calibration block that
                                                                             provides amplitude
   Adjust the sensitivity (gain) so that the larger indication is set       differences, with sufficient
    at 80% of full screen height (FSH).                                      signal separation to prevent
   Without moving the search unit, adjust sensitivity (gain) to             overlapping of the two
    successively set the larger indication from 100% to 20% of               signals.
    full screen height, in 10% increments (or 2 dB steps).                  Frequency: not to exceed
   Read the smaller indication at each setting.                             three months. Or in
   The reading shall be 50% of the larger amplitude, within 5%              accordance with reference
    of FSH.                                                                  construction code.
In Accordance With ASME V (Article 4):                                   In Accordance With ASME V (Article 4):
   Position an angle beam probe on a basic calibration block.              Alternate: any other convenient reflector from any calibration
   Obtain indication from the 1/2T side-drilled hole about                  block may be used with angle or straight beam search units.
    midway along the time base.                                             Frequency: not to exceed three months or in accordance with
   The echo amplitude is set to a 80% FSH and the attenuator                reference construction code.
    (dB) reading is noted.
   The attenuator setting is then reduced by 6 dB, four or five
    times in succession and the decrease in echo amplitude is
    noted every time.
   The indication shall fall within the specified limits
                                                                                                                                                   66
                                                                                                                                          4/2/2021
 Sensitivity and Signal to Noise Ratio  Sensitivity and Signal to Noise Ratio
   Provide a simple method which will identify deterioration in          Difference between the first and second measurements (dB)
    sensitivity of the probe and flaw detector in combination.             gives the S/N ratio.
   Place the probe on the V1 calibration block and adjust its            Frequency: The check shall be carried out once per probe per
    position to maximize the signal from the 1.5mm diameter                day or in accordance with procedure.
    hole.
   Adjust the gain control to set this signal to 20%FSH and note
    the dB setting (Sensitivity Value).
   Increase the gain until the overall system noise (electronic
    noise and grain structure grass) at the same range as the target
    hole reached 20%FSH and note the new dB setting.
   The first gain measurement noted provides a check on the
    sensitivity of the probe and flaw detector.
                                                                                                                                               67
                                                                                                                     4/2/2021
  Ability of an ultrasonic flaw detection system to give separate   Method (Using V1 Block):
   indication of discontinuities situated close together and
   simultaneously within the sound beam.
First Method (Using V1 Block):
 Calibrate the time base to a range of 0-100mm for Normal
   Probe .
 A probe is placed on the block and echoes from the three
                                                                          Poor Resolution       Better resolution,
   reflectors (85, 91 & 100 mm) are obtained.
 The separation of the echoes from each other indicates the
   degree of resolution of the flaw detector for that particular
   probe.
                                                                                                                          68
                                                                                                                                   4/2/2021
                                                                                 General           Procedure
                                                                  Collection of information prior to the testing of weld:
                                                                  i.     Parent metal specifications.
                                                                  ii.    Weld joint preparation.
                Weld Inspection                                   iii.   Welding processes.
                                                                  iv.    Parent metal thickness adjacent to the weld.
                                                                  v.     Any special difficulty experienced by the welder during
                                                                         welding.
                                                                  vi.    Location of any repair welds.
                                                                  vii.   Reference & Acceptance standards requirements.
                                                                                                                                        69
                                                                                                                                        4/2/2021
                                                                                                                                             70
                                                                                                   4/2/2021
                                                                                                        71
                                                                                                                                    4/2/2021
                                                                                                                                         72
                                                                                                                            4/2/2021
                                                                                                                                 73
                                                                                                                                         4/2/2021
  material. In weld metal, which is often coarsely crystalline,        penetrate further, than high frequency waves.
  the sound can be greatly impeded. This is especially true for       Resolution: High frequency probes have superior resolution
  austenitic stainless steel, where large crystals reflect some of     characteristics, so that small flaws can be found more readily,
  the sound back to the receiver, often to the extent that             than with low frequency probes.
  ultrasonic testing is impractical..
                                                                                                                                              74
                                                                                                                                      4/2/2021
  or V2 block.                                                     the specimen to the other, so that the probe index always
 Calculation of 1/2 skip distance (Stand off) and 1/2 beam
                                                                   coincides with the scan line.
  path length (1/2 BPL-Range) for the selected probe.             Areas with echoes from defects are marked on the specimen
 Marking of the scan lines at 1/2 skip distance from the weld
                                                                   for subsequent examination to establish the nature and size of
  center line on both sides of weld.                               the defects.
 Setting the gain sensitivity for scanning and evaluation.
                                                                                                                                           75
                                                                                                                                4/2/2021
  Good corner reflector.                                       side and little away from other side.
  Large echo amplitude compare to root under cut.            Less echo amplitude compare to lack of penetration.
 No root bead signal.  Root weld bead signal will also appear.
                                                                                                                                     76
                                                                                                                                      4/2/2021
  The echoes will maximize when the probe is moved forward            700 probe and also range increases.
   from both scanning line.                                           Probe Movement - echo falls rapidly when angle probe
                                                                       traversed forward.
                                                                      Measurement - it is not possible to measure depth with angle
                                                                       probe. Length difficult but usually by 6dB.
                                                                                                                                           77
                                                                                                                                       4/2/2021
 Measurement - lateral for 6dB drop.                                Determination of the correct probe index and angle using VI
                                                                      or V2 block.
                                                                     Calculation of 1/2 & full skip distance and 1/2 BPL & full
                                                                      beam path length (BPL) for the selected probe.
                                                                     Marking the parent metal on both sides of the weld with lines
                                                                      parallel to the weld center line and at distances of 1/2 skip
                                                                      and full skip +1/2 cap width.
                                                                                                                                            78
                                                                                                                    4/2/2021
                                                                                                                         79
                                                                                                                                        4/2/2021
 Rotate or orbit: echo falls rapidly.  Rotate or orbit: echo falls rapidly but over larger angle
                                                                                                                                             80
                                                                                                                                       4/2/2021
                                                                                                                                            81
                                                                                                                                        4/2/2021
Sinθ= ID/OD
                                                                                                                                             82
                                                                                                                   4/2/2021
   For a given probe angle, the maximum wall thickness of a       Review the following codes for understanding.
    pipe that allows the center of the beam to reach the bore of
    the pipe can be calculated from the following formula:            ASME V Article 4
                                                                      ASME VIII Appendix 12
                                                                      AWS D1.1 (Part F)
 Thank You