In part of the Lighting Fixtures for Marine & Industrial Use, we have grown up a
special company which is firm in reality...
Kukdongelecom Co., Ltd. established in 1992 is the company which produce the Lighting
Fixtures for Marine & Industrial Use with foothold in the production of Multi Cable Transit.
We have developed the Lighting Fixtures for Marine & Industrial Use, Reefer Container
Sockets (RCS), Multi Cable Transit (MCT), Electric Components for Rolling Stock (KTX,
subway), Night Vision System, etc and it has brought the innovative changes in the field.
Main customers of our company are the domestic 7 biggest shipbuilders including
HYUNDAI Heavy Industries Co. Ltd., and we are exporting to Japan, China, Vietnam,
Turkey, India, Singapore, Malaysia, Thai, Dubai, etc.
We have acquired the certificates of ISO9001(the quality management system) and
ISO14001(the environment management system). As well as we acquired a membership
of I.S.E.S (International Ship Electrical & Engineering Service Association) that is the
worldwide service network for Q.A. So we have been recognized the favorable criticism
and excellence of the quality from our customers all over the world, and have grown up a
President special company which is firm in reality in part of the Lighting Fixtures for Marine & Industrial
JONG-KI LEE Use.
[Value In Present]
Trying to make change of 90% and fill a lack of 10%...
Recently, we developed 'the Night Vision System for Surveillance' & 'the Night Vision
System for Navigation', and are preparing to supply them to the biggest 7 shipbuildings, the
defense industry part in domestic and export to the 15 foreign countries with our brand.
Specially, It is only our company that possesses the technology of 'the Night Vision System
for Surveillance' & 'the Night Vision System for Navigation' at the same time, and they are
paid more attention because of the technology that they can prevent massive human &
physical damage. The Night Vision System for Surveillance is a device that is possible to
realize 30cm*30cm characters of the distant objective about 2~3km at night and keep the
proof dada. And the Night Vision System for Navigation is a device that can discriminate
exactly the object in night and fog.
Recently, we were chosen as a 'Technology Innovation for SMEs (INNO-BIZ enterprise)'
with grade "Aa" at the same kind of industry for the first time, as well as we are selected as
a 'Leading enterprise for the Lighting Fixtures for Marine & Industrial Use' as the strategic
industry from Busan Metropolitan City and are evaluated to the company with competitive
power as 'Venture business' now. In 2007, we obtained the honor that were awarded 'The
export prize for 10 million dollars' (18.70 million dollars results) and won the official
commendation from 'The Ministry of Commerce, Industry & Energy', and will make an
endless effort for 'The export prize for 30 million dollars' in 2009.
[Value In Future]
Hereafter 50 years, we dream that we will be the world best company but small
one...
Now, a Light Emitting Diode (LED) is prospected as the light source for next generation,
and especially it is the strategic base of the technology industry that prepares to energy
exhaustion and a crisis of the environmental pollution. The LED with low-power
consumption, Semi-permanent and long life-time is expected to get into the spotlight as a
power of growth for next generation by replacing of the incandescent light and the
fluorescent light.
We are seeking a continuous change and innovation through a creative combination of 3
spirits that are the quality, the function, the accuracy. Also, we produce the best products
and we will do ceaseless effort to be "the world best company that is enlarging investment
about R&D for new growth power continuously as hereafter 50 years' survival strategy, and
exports the lighting fixtures for a shipbuilding and OFF-SHORE" through a mutual
competition in international market.
“We always think "3H kinds of spirit" that are 'High Quality, High Service, High
Efficiency' as the first principle, so we will keep a promise of the trust about 'the
quality, the service, the accuracy' for customers.”
1992>>1999
Established as KukDong lndustries Co., Ltd.
Merged & acquired the electrical manufacuring company, Myung Sung Industries Co."
History
Listed as a member of Busan Marine Equipment Association No.80
Factory moved to Dadae-dong Saha-ku in Busan. (Area : 2,393㎡, Building Area : 5,334㎡)
Acquired the Certificate for ISO 9001 Quality System from EAQA of United Kingdom.
Received“USD 1 million export trophy" from the president and a letter of commendation
from Prime Minister at the 36th Trade Day.(Export sales record ; USD 2,300,000 / No. 45782)
2000
Took over the lighting manufacturer‘Dong-Sung Electrical Co. Ltd.’
Changed the company name“ Kukdong Elecom Co., Ltd ”
Contracted a project for the school and industry cooperation with Ho-seo University.
Joined as a member of KOMEA (Korea Marine Equipment Association)
2001
Became a member of ISES for the worldwide after service network.
Selected as a promoted company by Korea Technology Credit
Fundamental Foundation ( TECF)
Selected as a Family Company by Korea Small and Medium Industry Bank.
The First Turnover from Shipbuilding Field at the STX Shipbuilding Company.
2002
Acquired Certificate for ISO 9001/2000 Quality from BV of France
Received USD 5 million export trophy" from president and a letter
of commendation form Prime Minister, at the 39th Trade day.
2003
Established a branch Office Seoul
Acquired the certificate for KS (Korean Standard) from Korea Standard Association
(No.03-4419)
2005
Completed "1 st step innovation consulting" (Jan. 5th.2005~Jul. 4th. 2005)
Received a government approval for the domestic development
“Project of-Project"
2006
Took over 3rd factory of KTE (Be 2nd Kukdong Elecom Factory)
Achieved the Certificate of Flame-Proof Lighting for Marine from Korea
Marine Equipment Research Institute.
Contracted "Sea Drill Project" from DAEWOO Shipbuilding working with
COOPER Crouse-Hinds.
Kukdong Elecom Factory advanced into Dalian, China.
Factory name : D.Kesko Co.,Ltd
Opened the branch office of Kukdong Elecom in Gwaebup-dong, Busan.
Opened the additional Web-site (www.kesko.co.kr)
2007
Appointed as the leading company for strategic industry from The Busan city.
Accepted to supply our lighting without the inspection from Hyundai Heavy lndustries.
Be entrusted our lighting quality by our inspection from DSME.
Contracted "OFF SHORE project 6 Sets" from LABROY in Singapore working with
COOPER Crouse-Hinds.
Acquired the ISO /KS A 14001 Quality System from BV of France
Received“USD 1 million export trophy" from the president and a letter of commendation
from Prime Minister at the 44th Trade Day.
2008
1st award, 2008 Korea Innovation Management, By Newspeople
Establish 3rd of KukdongElecom Factory
Participated “VIETSHIP 2008” Fair
Participated “2008 South-east Asia Market Developing Association”
Appointed as “Venture Company” from Korea Venture Industry Association
CONTENTS
2 FLOOD LIGHTS
3 SEARCH LIGHTS
7 SWITCHES
4 FLUORESCENT LIGHTS
8 RECEPTACLE AND PLUGS
5 INCANDESCENT LIGHTS
9 JUNCTION BOX
6 DECORATIVE LIGHTS
10 EXPLOSION-PROOF LIGHTS
12 WORKING LIGHTS
13 TECHNICAL INFORMATION
NAVIGATION & SIGNAL LIGHTS
www.kukdongelecom.com
1-1 NAVIGATION & SIGNAL LIGHTS / SINGLE / N-S
Optional
With1.5M cable(TPNP-1.5)
www.kukdongelecom.com..........1-1
NAVIGATION & SIGNAL LIGHTS / DUAL / N-D
Technical Drawing
Optional
With 1.5M cable(TPNP-1.5)
Optional
With Dimmer switch for Panama steering light
NAVIGATION
www.kukdongelecom.com..........1-3
SIGNAL LIGHTS / SL-P
Technical Drawing
www.kukdongelecom.com..........1-5
RECEPTACLE / SURFACE / RTDS-SW
Technical Drawing
www.kukdongelecom.com..........1-7
MORSE SIGNAL LIGHT / SL-M
Technical Drawing
www.kukdongelecom.com..........1-9
MORSE KEY SWITCH / FLUSH / MK-FS
Technical Drawing
www.kukdongelecom.com
2-1 HALOGEN FLOOD LIGHTS / PFH-20
www.kukdongelecom.com..........2-1
HALOGEN FLOOD LIGHTS / PFH
Technical Drawing
www.kukdongelecom.com..........2-3
H.P.SODIUM FLOOD LIGHTS / PFSI-40 / PFMH-40
Technical Drawing
Technical Drawing
www.kukdongelecom.com..........2-5
H.P. SODIUM FLOOD LIGHTS / PFSI-IP68 / PFMH-IP68
Technical Drawing
Optional
Reflector : Wide beam
KUKDONG ELECOM CO.,LTD......2-6
INCANDESCENT FLOOD LIGHTS / PFI-20
Technical Drawing
www.kukdongelecom.com..........2-7
INCANDESCENT FLOOD LIGHTS / PFI
Technical Drawing
www.kukdongelecom.com..........2-9
PORTABLE FLOOD LIGHTS / PFIP / PFHP
Technical Drawing
Technical Drawing
www.kukdongelecom.com..........2-11
PROJECT LIGHTS / PPI / PPM
Technical Drawing
BT40MH 2x400W 234 444 136 19.7 Metal halide Ballast unit for flood lights with H.P.Sodium, metal halide
BT40M 1x400W 234 444 136 11.2 Mercury
and mercury lamp Protection degree : IP56
The body structure is latch locked on the cable connection
BT40M 2x400W 234 444 136 19.7 Mercury and maintenance is very easy.
Materials
Housing : Electrolytic Galvanized Iron steel sheet deep
drawn,seamless
Cover : Electrolytic Galvanized Iron steel sheet deep
drawn,seamless
Finish
Powder coated blue green 7.5BG7/2
and enamelled up to 70~80㎛ thickness
Specification
Light sources : H.P.Sodium lamp, 1x400W, 2x400W
Metal halide lamp, 1x400W, 2x400W
Mercury lamp, 1x400W, 2x400W
Cable entry : Three(3) cable glands
Two(2) cable glands M24x1.5
(Max.diameter 17mm cable),
One(1) cable gland M30x1.5
(Max.diameter 20mm cable)
Voltage and frequency : AC220V 60Hz are standard
Others on request
Optional
Housing : Stainless steel sheet deep drawn
Cover : Stainless steel sheet deep drawn
LIGHTS
FLOOD
www.kukdongelecom.com..........2-13
SEARCH LIGHTS
www.kukdongelecom.com
3-1 HALOGEN SEARCH LIGHTS / PSHR
Application
Bridge wing
Chemical processing and industrial
Design
According to rules of maritime classification
societies, additional IEC
Model no. and Dimensions Features
Range A B C D M1 M2 Weight
Model no. Capacity
Luminous
[m, 1ux at Remark Protection degree : IP56
intensity (kg)
target] (mm) Remote control type
PSHR-1K 1,000W 1.0X 106cd 1,250 417 Φ310 811 991 250 370 50 Luminous effciency : 26lm~30lm/w
PSHR-2K 2,000W 6
2.7X 10 cd 1,500
High luminance
692 Φ630 1,230 1,545 340 460 155 Color rendering coeffcient : Ra>90
6
PSHR-3K 3,000W 3.0X 10 cd 1,730
Color temperature : 2,880K~3,200K
Light color can be maintained unti life time
As soon as light up, whole luminous flux amount occurrence
Small size and light weights
Separate control panel with ON/OFF switch and joystick switch
Materials
Body : Stainless steel sheet
Arm : Steel zinc coated
Reflector : Glass parabolic mirror
Front glass : Tempered glass
Finish
Powder coated white N-9.3
and enamelled up to 70~80㎛ thickness
Specification
Light sources : Halogen lamp
1,000W, 2,000W, 3,000W
Lamp base : GX9.5, GY16, G38
Horizontal rotation 350。, 11。/sec
Vertical movement upward 20。 / downward 40。
, 3。
/sec
Cable entry : Three(3) cable glands M24x1.5
(Max.diameter 17mm cable)
Mounting : 4 mounting holes, dia. 17mm
Voltage and frequency : AC220V 60Hz are standard
Others on request
SEARCH
LIGHTS
www.kukdongelecom.com..........3-1
HALOGEN SEARCH LIGHTS / PSHF / PSHC / PZHF
Technical Drawing
Application
Bridge wing
Chemical processing and industrial
Design
According to rules of maritime classification
societies, additional IEC
Model no. and Dimensions
Luminous
Range A B C D Weight
Features
Model no. Capacity intensity [m, 1ux at (kg)
Remark
Protection degree : IP56
target] (mm)
Fixed type
Fixed type Luminous effciency : 26lm~30lm/w
6
PSHF-1K 1,000W 1.0 x 10 cd 1,250 417 Φ310 400 555 16.5 High luminance
PSHF-2K 2,000W
6
2.7 x 10 cd 1,500 Color rendering coeffcient : Ra>90
6
692 Φ630 682 997 60 Color temperature : 2,880K~3,200K
PSHF-3K 3,000W 3.0 x 10 cd 1,730
Light color can be maintained until life time
Cabin Control type As soon as light up, whole luminous flux amount occurrence
PSHC-1K 1,000W 1.0 x 10 6cd 1,250 417 Φ310 400 555 20 Small size and light weights
PSHC-2K 2,000W 6
2.7 x10 cd 1,500 Materials
692 Φ630 742 1,057 65
PSHC-3K 3,000W
6
3.0 x 10 cd 1,730 Body : Stainless steel sheet
Arm : Steel zinc coated
Signalling type
6
Reflector : Glass parabolic mirror
PZHF-1K 1,000W 1.0 x 10 cd 1,250 578 Φ369 458 664 34
Front glass : Tempered glass
Finish
Powder coated white N-9.3
and enamelled up to 70~80㎛ thickness
Specification
Light sources : Halogen lamp
1,000W, 2,000W, 3,000W
Lamp base : GX9.5, GY16, G38
Horizontal rotation 350。
Vertical movement upward 45。/ downward 45。
Exterior connection box
Cable entry : One(1) cable gland M24x1.5
(Max.diameter 17mm cable)
Mounting : 4~6 mounting holes, dia. 19mm
Voltage and frequency : AC220V 60Hz are standard
Others on request
SEARCH
LIGHTS
Application
Bridge wing
Chemical processing and industrial
Design
According to rules of maritime classification
societies, additional IEC
Model no. and dimensions Features
Luminous
Range A B C D M1 M2 Weight Protection degree : IP56 / Remote control type
Model no. Capacity intensity [m, 1ux at Remark
target] (mm)
(kg) Luminous effciency : 28lm/w / High luminance
PSXR-1K 1,000W 50x10 6cd 6,300
Color rendering coeffcient : Ra>90
605 496 1,063 1,284 250 370 105 Color temperature : 6,000K
PSXR-1.6K 1,600W 88x10 6cd 7,500 Light color can be maintained until life time
PSXR-2K 2,000W 110x10 6 cd 8,000 Stable are
PSXR-2.5K
6
2,500W 130x10 cd 8,800 750 656 1,348 1,638 340 460 140
As soon as light up, whole luminous flux amount occurrence
6
Small size and light weights
PSXR-3K 3,000W 150x10 cd 9,900
Separate control panel with ON/OFF switch and control switch
6
Materials
PSXR-4.5K 4,500W 190x10 cd 11,200 810 730 1,410 1,720 340 460 160
6
PSXR-7K 7,000W 291x10 cd 14,500 860 780 1,510 1,820 390 510 175 Body : Stainless steel sheet / Arm : Steel zinc coated
Reflector : Glass parabolic mirror
Front glass : Tempered glass
Finish
Powder coated white N-9.3
and enamelled up to 70~80㎛ thickness
Specification
Light sources : Xenon lamp / 1,000W~7,000W
Lamp base : Maker supply / Lamp capacity : DC24V
Horizontal rotation 350。, 11。/sec
Vertical movement upward 20。 / downward 40。
,3。
/sec
Cable entry : Three(3) cable glands M24x1.5
(Max.diameter 17mm cable)
Mounting : 4 mounting holes, dia. 13mm~17mm
Voltage and frequency : AC220V 60Hz are standard
Others on request
Optional
Fixed type
CCTV camera is installed the upper part type
ICE Class type
SEARCH
LIGHTS
www.kukdongelecom.com..........3-3
POWER SUPPLY UNIT / PU
Technical Drawing
Technical Drawing
www.kukdongelecom.com..........3-5
SUEZ CANAL SEARCH LIGHTS / PCH-2K
Technical Drawing
Optional
With 3M cable(TPNP 1.5)
KUKDONG ELECOM CO.,LTD......3-6
RECEPTACLE W/SWICH & PLUG / RTSC-30P
Technical Drawing
www.kukdongelecom.com..........3-7
FLUORESCENT LIGHTS
www.kukdongelecom.com
4-1 FLUORESCENT LIGHTS / FS - W - S
www.kukdongelecom.com..........4-1
FLUORESCENT LIGHTS / FS - W - U
www.kukdongelecom.com..........4-3
FLUORESCENT LIGHTS / FS - N
www.kukdongelecom.com..........4-5
FLUORESCENT LIGHTS / FW - N
www.kukdongelecom.com..........4-7
FLUORESCENT LIGHTS / FF - S
Optional
Battery back up to 180 min
Electronic start
Dimming control system
Optional
Electronic start
Model no. and Dimensions
Em’cy L D H Weight
Model no. Capacity Volt Hz
Lamp (mm) (kg)
FS210S 1x18W 220 60 711 146 82.4 4.22
www.kukdongelecom.com..........4-9
FLUORESCENT LIGHTS / FP - N
Optional
Electronic start
Optional
Protection degree : IP44
www.kukdongelecom.com..........4-11
FLUORESCENT LIGHTS / FB09SN
www.kukdongelecom.com..........4-13
FLUORESCENT LIGHTS / FPH-P
Technical Drawing
Shock mount
www.kukdongelecom.com..........4-15
INCANDESCENT LIGHTS
www.kukdongelecom.com
5-1 INCANDESCENT LIGHTS / IPH-P
Others on request
Optional
Guard : Cast brass
Screen : Stainless steel
LIGHTS
Hanging hook
www.kukdongelecom.com..........5-1
INCANDESCENT LIGHTS / IPN-B
Technical Drawing
IPN-20WG-B 20W DC24V 170 142 155 1.9 Guard Body : Natural
Guard : Natural
Specification
Light sources : Incandescent lamp
20/40/60/100W
Lamp base : E27, B15(DC24V)
Cable entry : Two(2) cable glands M24x1.5
(Max.diameter 17mm cable)
Mounting : 3 mounting holes, dia.10mm
Voltage and frequency : AC220V are standard
INCANDESCENT
Others on request
Optional
Screen : Stainless steel
LIGHTS
Flange seat
www.kukdongelecom.com..........5-3
INCANDESCENT LIGHTS / IKN-B
Technical Drawing
Optional
Screen : Stainless steel
Flange seat
LIGHTS
Others on reques
Optional
Screen : Stainless steel
LIGHTS
Technical Drawing
Others on request
Optional
Flange seat
LIGHTS
www.kukdongelecom.com..........5-7
INCANDESCENT LIGHTS / IM
Technical Drawing
www.kukdongelecom.com..........5-9
INCANDESCENT LIGHTS / ICF
Technical Drawing
Finish
Housig : Powder coated white N-9.3
and enamelled up to 70~80㎛ thickness
Cover 5rame = Golden plated / Silver plated
Specification
Light sources : Incandescent lamp, 40/60W
Halogen lamp, 35W,50W
Lamp base : E27
Cable entry : Two(2) cable inlet holes
(Max.diameter 17mm cable)
Mounting : 4 mounting holes, dia.5mm
Voltage and frequency : AC220V 60Hz are standard
Others on request
INCANDESCENT
Optional
Cover flame : Gloden plate
Red Bulb
With Terminal block box
With Screen
LIGHTS
www.kukdongelecom.com..........5-13
CHART TABLE LIGHTS / ITS
Technical Drawing
www.kukdongelecom.com
6-1 DECORATIVE LIGHTS / DNLF13 / 18
Optional
Electronic start
Dimming control system
B15 Fire class
DECORATIVE
www.kukdongelecom.com..........6-1
DECORATIVE LIGHTS / IDS-F
Technical Drawing
www.kukdongelecom.com..........6-3
DECORATIVE LIGHTS / FDW-D
Technical Drawing
www.kukdongelecom.com..........6-5
DECORATIVE LIGHTS / IDS
Technical Drawing
www.kukdongelecom.com..........6-7
DECORATIVE LIGHTS / IDW-A
Technical Drawing
www.kukdongelecom.com..........6-9
DECORATIVE LIGHTS / DNFH-TB
Technical Drawing
www.kukdongelecom.com..........6-11
EXIT LIGHTS / EL10-WS
Technical Drawing
www.kukdongelecom.com
7-1 SWITCHES / JIS TYPE / SR-SIW-P
Technical Drawing
www.kukdongelecom.com..........7-1
SWITCHES / DIN TYPE / SR-SIW-D
Technical Drawing
www.kukdongelecom.com..........7-3
SWITCHES / ST-FIN-P
Technical Drawing
www.kukdongelecom.com..........7-5
SWITCHES / ST-S1N-P
Technical Drawing
www.kukdongelecom.com..........7-7
SWITCHES / ST-S1S-P
Technical Drawing
Technical Drawing
www.kukdongelecom.com..........7-9
SWITCHES / PBE-S
Technical Drawing
www.kukdongelecom.com..........7-11
SWITCHES / PBR
Technical Drawing
www.kukdongelecom.com
8-1 RECEPTACLE / DIN Type / RTS-D31W
www.kukdongelecom.com..........8-1
RECEPTACLE / DIN Type / RT-D31
Technical Drawing
www.kukdongelecom.com..........8-3
RECEPTACLE / Old JIS Type / RTS-J31W
Technical Drawing
www.kukdongelecom.com..........8-5
RECEPTACLE / Old JIS Type / RT-J32W
Technical Drawing
Technical Drawing
www.kukdongelecom.com..........8-7
RECEPTACLE / New JIS Type / RTS1-31W NEW JIS
Technical Drawing
www.kukdongelecom.com..........8-9
PLUG / OLD JIS Type / PG-J3W
Technical Drawing
Technical Drawing
www.kukdongelecom.com..........8-11
RECEPTACLE / DIN Type / RT-D31NF-P
Technical Drawing
www.kukdongelecom.com..........8-13
RECEPTACLE / DIN Type / RT-D31N-P
Technical Drawing
www.kukdongelecom.com..........8-15
RECEPTACLE / DIN Type / RT-D31SF-P
Technical Drawing
www.kukdongelecom.com..........8-17
RECEPTACLE / DIN Type / RT-D31S-P
Technical Drawing
www.kukdongelecom.com..........8-19
JUNCTION BOX
www.kukdongelecom.com
9-1 JUNCTION BOX / JBW-RB
www.kukdongelecom.com..........9-1
JUNCTION BOX / JBW-QP
Technical Drawing
www.kukdongelecom.com..........9-3
JUNCTION BOX / / JBN-RP
Technical Drawing
www.kukdongelecom.com
10-1 INCANDESCENT LIGHTS / IX-20d
Optional
EXPLOSION-
Voltage : AC220V
www.kukdongelecom.com..........10-1
INCANDESCENT LIGHTS / IX-d
Technical Drawing
www.kukdongelecom.com..........10-3
INCANDESCENT LIGHTS / PX-I
Technical Drawing
www.kukdongelecom.com..........10-5
H.P.SODIUM / HALOGEN LIGHTS / PX-S / PX-H
Technical Drawing
www.kukdongelecom.com..........10-7
INCANDESCENT LIGHTS / IX1-d
Technical Drawing
www.kukdongelecom.com..........10-9
INCREASED SAFETY FLUORESCENT LIGHTS / FX-edm
www.kukdongelecom.com..........10-11
NON SPARKLING FLUORESCENT LIGHTS / FX-nA-F / FX-nA-C
Optional
Reflector : Wide beam
www.kukdongelecom.com..........10-13
NON SPARKING SODIUM LIGHTS / PX-S40nR
Technical Drawing
Others on request
Optional
EXPLOSION-
Others on request
Optional
EXPLOSION-
www.kukdongelecom.com..........10-15
NON SPARKING BALLAST BOX / BX-S42nR
Technical Drawing
www.kukdongelecom.com..........10-17
CONTROL KEY SWITCH / SRK-S
Technical Drawing
www.kukdongelecom.com..........10-19
EXPLOSION-PROOF JUNCTION BOX / JBX
Technical Drawing
www.kukdongelecom.com..........10-21
REEFER SOCKET OUTLET DEVICES
www.kukdongelecom.com
11-1 SOCKET OUTLETS PUSH PULL TYPE / 10GANG
Features
Fixed wired module(Standrad type)
Protection degree : IP56/67
Heavy gauge powder coated stainless steel enclosure and integral
mounting bracket
Electrical protection and locking device
Construction : stainless steel housing and interlock
Model no. and Dimensions mechanism, impact resistant non-metallic sockets and
bayonet cap, nickel plated brass contacts per power unit
L D H M1 M2 Weight
Model no. Remark one circuit breaker with thermal magnetic tripping, 32A rated
(mm) (kg)
current, 10kA short circuit-breaking capacity
RCS2-321F 300 140 290 250 0 11.7 Approval GL for 1gang~10gang
RCS2-322F 440 140 290 390 0 15.5
Materials
RCS2-323F 560 140 290 510 0 18.4
Housing & Cover : Welded stainless steel construction (SUS304)
RCS2-324F 660 140 290 630 0 22.1 Sealing : Highly flexible hllow seal for the cover
RCS2-325F 800 140 290 375 375 26.4 Socket : Integrated with resin socket flange,
with exchangeable socket insert, high quality lamella contacts,
RCS2-326F 920 140 290 375 495 30.8
resin bayonet cap
RCS2-327F 1070 140 290 503 523 35.2 Connection terminal : Horizontally beside one with another
RCS2-328F 1190 140 290 643 503 40.7 Cable gland : housing rotation
RCS2-329F 1316 140 290 358 550 45.1
Finish
RCS2-3210F 1436 140 290 478 430 50.9 Powder coated blue green 7.5BG 7/2
and enamelled up to 70~80㎛ thickness
380VAC to 440VAC, 32A (C.E.E / I.E.C/ I.S.O) Specification
Without monitoring socket
AC440V, 32A / 3P +1E
Mounting : External fixing lugs ,4~6 mounting holes, dia.14mm
Optional
Custom designed enclosures
Plug-in module
With 4-pole monitoring sockets
Auxiliary switches and monitoring contacts wired to terminals
Loop-through version for power supply cable
Installation of monitoring electronic
SOCKET OUTLETS
www.kukdongelecom.com..........11-1
SOCKET OUTLETS LEVER TYPE / 5GANG
Features
Fixed wired module(Standrad type)
Protection degree : IP56/67
Heavy gauge powder coated stainless steel enclosure and
integral mounting bracket
Electrical protection and locking device
Construction : stainless steel housing and interlock
Model no. and Dimensions mechanism, impact resistant non-metallic sockets and
bayonet cap, nickel plated brass contacts
L D H M1 M2 Weight Per power unit one circuit breaker with thermal magnetic
Model no. Remark
(mm) (kg) tripping, 32A rated current, 10kA short circuit-breaking
RCS2-321F 300 157 290 250 0 13.5 capacity
Approval GL for 1gang~10gang
RCS2-322F 440 157 290 390 0 17.3
Optional
Custom designed enclosures
Plug-in module
With 4-pole monitoring sockets
Auxiliary switches and monitoring contacts wired to terminals
SOCKET OUTLETS
www.kukdongelecom.com
12-1 EX-P. WORKING LIGHTS / ELX-F32H
www.kukdongelecom.com..........12-1
WORKING LIGHTS / EL-F32H / EL-F32B
Technical Drawing
26w = 150w
WORKILG
32w = 200w
LIGHTS
Application
① : For ceiling (Steel) on Shipboard
and Yards
② : For Wall (Steel) on Shipboard and Yards
③ : For Stair Way, Passage Way
and Outdoors
④, ⑤ : For Portable use on Working Areas
⑥~⑧ : For Brightness of Working Areas for
Ceiling and Well
Iluminance[Lx]
Distance 1M from Lighting Sources
①~④ : 170 [Lx]
⑤ : 732 [Lx]
⑥ : 457 [Lx]
⑦ : 588 [Lx]
⑧ : 697 [Lx]
④ PORTABLE TYPE ③ BRACKET TYPE
EL-F32P FPL 32W×
×1 EL-F32B FPL 32W×
×1
www.kukdongelecom.com..........12-3
TECHNICAL INFORMATION
www.kukdongelecom.com
13-1 DESCRIPTION FOR LIGHTING SOURCES
13-22 CERTIFICATION
TECHNICAL INFORMATION
Color temperature expresses the light color tone physically and objectively. Choosing the color tone is very important for determining the mood of
a place. If the color temperature(K) is low then the light color becomes orange and it looks warm.
If the color temperature(K) is high then the light color becomes white like natural light. Even higher temperatures will produce a blue color that
looks cool.
Color Rendering is expressed in color fidelity from the lighted object. The unit is color rendering
coefficient(light) effect on color. Color rendering coefficient expresses similarity between the
object’s light color and natural light.
We use different method to determine color rendering coefficient by comparing the standard light
and the experimental light. If the experimental light is same as the standard light, then Ra is 100.
Color differentiation and Ra disproportion to each other. Good color rendering is close to 100.
Generally over 80 average color rendering coefficient is considered good color rendering.
Light distribution shows unit wave density (energy) of light. For ideal light, which has constant light
density without deflection in visible light range, consider color rendering seriously.
The following figure is a fluorescent lamps’s light distribution with a Ra 99 average color rendering
coefficient. From this, we can determine these above conditions are satisfied.
INFORMATION
TECHNICAL
www.kukdongelecom.com..........13-1
TECHNICAL INFORMATION
Luminous lm
Luminous flux is the total amount of vislble light that comes from the light source.
flux (lumen)
Luminous cd
intensity (candela) Luminous intensity is how much Luminous fiux goes to an area from the light source.
Illuminance Ix (lux)
Brightness of the unit area.
(1lx = Illuminance of 1 lm’s average luminous flux on 1㎡)
Power W (watt)
Power consumption of lamps is on the lamp and in the catalog
consumption
The total time the lamp will last after turning it on and off when tested under specific conditions.
Hr (hours) Or the period of time it takes for lamp and luminous fiux to tall below the requirements the
Lifetime
lamp’s life ceases, whichever comes first is the lamp’s lifetime
The aveage life of a lamp after asfter turning it on when we tested underspecific
Average Hr (hours)
conditions,
lifeime
several lamps (described in the catalog)
A fluorescent lamp with FL 40W (luminous flux 3,100lm) will have a luminous efficiency or 3,100/40 = 77.5 (lm/w) Therefore, the
luminous efficiency (lm/w) will be high and the light will be bright and economical.
INFORMATION
TECHNICAL
Average
Kind Color Average
Capacity Effciency color
of Temperature Ballast Life time Advantages Disadvantages
(W) (Im/w) rendering
Lamps (。K) (hr)
(Ra)
1. Continuous
Incandescent spectrum and
filament 10~1.000 16~20 3.000 100 unnecessary 1.000 1. Low effclency
enough coir
lamp Hight power
rendering.
consumption
2. No flicker.
for equal
3. Lamp must adapt
illuminance.
according to
2. Less absolute
lumminous flux
luminous fiux
simuitaneously.
than dischsrge
4. Small and light, low
lamp.
2.800 facilities cost.
Halogen 3. Produces a lot of
100~1500 50 ~ 100 unnecessary 2.000 5. Halogen lamps do
lamp heat.
3.200 not reduse luminous
flux during life.
1. Less color
1. Big lamp size.
3.500 rendering.
Fluorescent 2. Sensitive to
4~110 40~90 ~ 60~95 unnecessary 10.000 2. Does not
lamps ambient
6.500 produce a lot
temperature.
of heat.
1. Better color
rendering and
flicker than Halide
Ballastless lamp. 1. Lower
Mercury 2. Ballast not efficiency
300~750 17~30 3.600 58 unnecessary 9.000
Fluorescent necessary. than mercury
lamp 3. Bright light lamp.
from the filament
immediately after it
is turned on.
www.kukdongelecom.com..........13-3
TECHNICAL INFORMATION
Average
Kind Color Average
Capacity Effciency color
of Temperature Ballast Life time Advantages
(W) (Im/w) rendering
Lamps (。K) (hr)
(Ra)
1. Light is very
similar to
natural light
Xenon 600~ 21~28 6.000 95 unnecessary 2.000 and excellent
lamp 20.000
color rendering
2. Large capacity
possible
1. The highest
Low luminous
effciency
pressure
35~180 130~175 1.800 16 unnecessary 9.000 2. Hot toxic
sodium 3. Good
lamp transmission in
the fog
1. An
1. Very high
High lmprovement
luminous
over the low
pressure effciency
250~1.000 92~130 2.000 29 unnecessary 12.000 pressure
sodium 2. Less toxic
Sodium lamp
lamp 3. Large capacity
but color is
possible
insufficient.
INFORMATION
TECHNICAL
E= Ⅰ (cosa)³
h²
E=Illuminance
I =Luminous lntensity
α=Angle of radiation
P=Illuminance in the calculated point
H=Suspension height
h=H-0.85m (normal effective plane)
Should the luminaire be directed on to the calculated point, then the following formula is applicable:
Ⅰ
E=
h²
Should the cones of light intersect each other because of the installation of several luminaires, the illuminance can then totalled be at
these points.
The illumination effectiveness, is normaly related to a horizontal plane 0.85 m over the ground(measuring and effective plane).
The factor 1.25 takes into account the decrease of luminous flux caused by aging and/or contamination of the lighting system.
The illumination effectiveness ηB is the product of the luminaire’s effectivity factor ηLB and the area effectivity factor ηR
ηB=ηR·ηLB
Depending on the individual design and light distribution, a luminare’s operational effectivity can vary considerably:
The area effectivity factor ηR takes into account the fact that only part of the luminous flux emitted from the luminaire reaches the effective plane because
of absorption by the walls, ceiling and floor. It is dependent on the light distribution from the luminaires, their respective positions in the room, the room
dimensions and the degree of reflection from the rooms boundaries. The rooms dimensions as well as the positioning of the luminaires in the room are
determined by area index k.
INFORMATION
TECHNICAL
a b a = length of room
k= b = width of rppm
h(a+b)
h = height of luminaire above effective plane
www.kukdongelecom.com..........13-5
TECHNICAL INFORMATION
THE RANGES OF VOLTAGE AND FREQUENCY FOR LIGHTING FIXTURES IN THE WORLD
( 1 OF 2 )
VOLTAGE FREQUENCY
NO NAME OF COUNTRY REMARKS
(VAC) 50Hz 60Hz
1 100 ○ ○ Japan
2 110 ○ Guyana
3 110 ○ Haiti Philippines
4 110 ○ ○ Bolivia
5 110,220 ○ Jamaica Lebanon Libya
Belize Colombia Domincan Rep.
6 110,220 ○
Ecuador Korea Panama
7 110,227 ○ Senegal
8 115 ○ Bermuda
9 115,120 ○ Cuba
10 115,230 ○ Trinidad & Tobago
12 120,240 ○ El Saivador
13 127 ○ ○ Mexico
14 127,240 ○ ○ Saudi Arabia
15 200 ○ ○ Jordan
Algeria Angola Argentina
Austria Belgum Benin
Botswana Bulgaria Burkina Faso
Ruma Bururndi Caeneroon
China CIS Comoros
Congo Czezho/Slovakia Denmak
Djibuti Egypt Ethilopia
Finland France French Guiana
French Polynesia gabon Garmany
Greece Greeniand Guadeloupe
Guinea Hong Kong Hungary
Iceland Inddonesia Iran
16 220 ○ Irak Ireland Italy
Ivory Coast Luxembourgr Madagascar
Mall Martinique Mauritanial
Mozambique Morocco Namibia
Nepal Netheriands New Caledonia
Niger Norway Papua(New Guinea)
Paraguay Poland Reunion
Romania R.S.A Rwansa
Somalia Spain Swaziland
Swweden Switzeriand Syria
Tahiti Thalland Togo
INFORMATION
( 2 OF 2 )
VOLTAGE FREQUENCY
NO NAME OF COUNTRY REMARKS
(VAC) 50Hz 60Hz
20 230 ○ India
22 250 ○ Ghana
INFORMATION
TECHNICAL
www.kukdongelecom.com..........13-7
TECHNICAL INFORMATION
VISBLITY
6 3 3 3 3 3
(NM)
THE VESSLE OF
50M OR MORE
VISBLITY
2 1set 1 2
(NM)
VISBLITY
THE VESSLE OF 5 2 2 2 2 2
(NM)
20M OR MORE
BUT LESS
Q’TY
THAN 20M 1 1set 1 1
OF LIGHT
VISBLITY
THE VESSLE OF 3 2 2 2 2 2
(NM)
12M OR MORE
BUT LESS
Q’TY
THAN 20M 1 1set 1 1
OF LIGHT
VISBLITY
2 1 2 2 2 2
(NM)
THE VESSLE OF
LESS THAN 12M
Q’TY
1 1set 1 1
OF LIGHT
VISBLITY
THE VESSLE OF 1 2
(NM)
LESS THAN 7M
BUT 7KONTS
Q’TY
OR MORE 1set 1
OF LIGHT
VISBLITY
1 2
THE VESSLE OF 50M (NM)
THAN 7M BUT
7KONTS Q’TY
Note3 1
OF LIGHT
NOTE:
1. The second masthead light except a vessel of less than 50 metes in length shall not be obliged to exhibit such light but may do so.
INFORMATION
2. The vessel of less than 12 metres in length may in lieu of lights prescribed in Rule exhibit an all-round white light and sidelights.
TECHNICAL
3. The vessel of less than 7 metres in length whose maximum speed does not exceed 7 konts may in lieu may in lieu of the lights prescribed in
Rule exhibit an all-round white light and shall, if practicable, also exhibit sidelights.
1. Electrical Data
1. Construction and resistance of conductor
⑴ Resistance Formula ;
L
R=ρ
A
R : resistance in ohm per phase
ρ: specific resistance,Ω ㎟/m
A : conductor area, ㎟
L : conductor length,m
R = R0〔1+α
(t-20)〕
R0 : reistance at t=20。C
t : conductor temperature, 。
C
a : 0.00393 for copper
www.kukdongelecom.com..........13-9
TECHNICAL INFORMATION
2. Current Ratings
1. EP Rubber Insulated Cable (a.c.,d.c.)
150 271 422 340 256 399 321 245 383 308
185 308 505 401 291 476 379 279 457 363
TECHNICAL
240 - - - - - - - - -
300 - - - - - - - - -
www.kukdongelecom.com..........13-11
TECHNICAL INFORMATION
Ambient temperature
No. of cores
(40。C) (45。C) (50。C)
A A A
2 14 14 13
4 12 11 11
7 9 9 9
12 7 7 7
19 6 6 5
27 5 5 5
37 4 4 4
44 3 3 3
77 3 3 3
Reference :
1. The values given above are for 6 cables or less bunched or laid together in flat formation.
When more han 6 cables are bunched or laid close together, a correction factor 0.85 should be applied to the values given above
2. Frequency : 60 Hz.
mm² (40。C) (45。C) (50。C) (40。C) (45。C) (50。C) (40。C) (45。C) (50。C)
A A A A A A A A A
1.5 25 24 23 21 20 19 18 17 16
2.5 34 32 30 29 27 26 24 22 21
4 44 42 40 37 36 34 31 29 28
6 58 55 52 49 47 44 40 39 37
10 79 75 71 67 64 61 55 53 50
Reference :
1. The values given above are calculated as the conductor temperature 95。C
2. The values given above are for 6 cables or less bunched or laid together in flat formation. When more than 6 cables are bunched or laid
close together, a correction factor 0.85 should be applied to the value given above.
INFORMATION
3. Frequency : 60Hz
TECHNICAL
0.75 12 11 10 10 9 8 10 9 8
1 15 14 13 12 11 11 12 11 11
1.5 18 17 16 15 14 13 15 14 13
2.5 25 24 23 21 20 19 21 20 26
4 34 32 31 28 27 26 28 27 26
6 43 41 39 36 34 32 36 34 32
Ambient Tempeature
Nominal sectional
area
(40。C) (45。C) (50。C)
mm² A A A
1.5 21 20 19
2.5 30 28 26
4 40 38 36
6 51 48 45
10 71 67 63
16 95 90 85
Reference :
1. The values given above are for 6 wires or less bunched or laid together in flat formation. When more than 6 wires are bunched or laid close
together, a correction factor 0.85 should be applied to the values given above.
INFORMATION
2. Frequency : 60Hz
TECHNICAL
www.kukdongelecom.com..........13-13
TECHNICAL INFORMATION
Ambient Tempeature
Nominal sectional
area
(40。C) (45。C) (50。C)
mm² A A A
0.75 12 11 10
1 14 13 12
1.5 18 17 15
2.5 26 24 22
4 35 32 29
6 44 41 37
10 62 57 52
16 82 76 69
Reference ;
1. The values given above are for 6 wires or less bunched or laid together in flat formation. When more than 6 wires are bunched or laid close
together, a correction factor 0.85 should be applied to the values given above.
2. Frequency : 60 Hz.
To make it easier to select appropriate electrical equipment todesign proper elelctrical installations. explosion-endangered areas
are divided into zones. Information and specifications for divison into zones. Information and specifications for this divison zones
are contained in IEC 60079-10 and in national standards.
An overrview of the division into zonnes the assignment of devices (device categiry as EC directive 94/9/EC) for the zones
concerned is shown in the table.
Definition (94/9/EC)
Gases, vapours, mists Dusts
Explosive atmosphere is present :
Zone 0 ⇒ category 1G Zone 20 ⇒ category 1D continuously or a long time or frequently
If doubts exist regarding the division into zones, then within the entire explosion - endangered area the scope of the eotecive measures should
be chosen in accordance with the highest possible of occurrence of a dangerous explosive atmosphere in the given case. In such cases, it is
advisable to seek assistance from expert organizations.
In zones 0 and 1, only electrical equipment for which a type test cerificate from a recognized test organizatopn exists may be used. In zone 0,
however, only equipment that has been expressly approved for this zone be used. In zone 2, the equipment approved for use in zones 0 and 1
may also be usedd. furthermore, in zone 2, electrical equipment may be used which meets the dasic safety requirements of directive 94/9 EC
and for which a declaration of conformity form the manufacturer exists.
Zone 0 Zone 1
explosive gas atmosphere
explosive gas atmosphere
= continuously or
= occasionally
for long periods
This usually applies to the inside of contaners This can apply to areas surrounding Zone 0
or apparatus (vaporizers, reactors etc,.) if areas surrounding charging doors areas
requirements of Zone 0 are met. surrounding fitting and drainig facilities areas,
where fragile apparatus, glass, ceramic or
similar tudes are installed areas surroundig
insufficently tight cable glands, e.g. on pumps or
vaves, the inside of equipment such a
vaporizeres, reactors.
INFORMATION
TECHNICAL
www.kukdongelecom.com..........13-15
TECHNICAL INFORMATION
2. Example of zone classification
Zone 2
Zone 1
explosive gas atmosphere
= for a short period only
Zone 0
Zone 1
It would be uneconomical, and sometimes even impossible, to always design all items of explosion-proof electrial equipment in
accordance with maximum requirements, regardless to the intended type of use. Therefore, division of the items of equipment
into groups and temperature classes is used in accordance with the characteristics of the explosive for which the equipment is
intended.
For electrical equipment of group Ⅱ, a further subdivision takes place into exposion groups and temperature classes.
An overview of the gap width limits and minimum ignition currents for the various explosion groups is shown in the following table:
ⅡC 0.5mm 0.45
From explosion group ⅡA to ⅡC, the degree of danger posed by the increases. The requirements to electrical equipment for these explosion
groups increase accordingly. Therefore, information must, if necessary, be shown on the items of electrical equipment, indicating which
explosion group they are designed. for. Electrical equipment for ⅡC may also be used for all other explosion groups.
4. Temperature Classes
The ignition temperature of a combustible gas or liquid is the lowest temperature of a heated surface at which ignition of the
gas/air or vapour/air mixture occurs. It is determined in a precsely defined experimental set-up (IEC 60079-4) and, in practice,
INFORMATION
represents the lowest temperature at which a hot surface can ignite the explosive atmosphere concerned.
TECHNICAL
The ignition temperature makes it possible to divide combustible gases and vapours into temperature classes according to their
ignitability. The maxture surface temperature of the gas/air or vapour/ari mixture in which it is used. Naturally. items of
equipment which correspond to a higher tomperature- class (e.g.T5) arealso permissible for uses in which a lower tomperature-
class (e.g.T2 or T3) is stipulated.
T2 300。C 300。C
T3 200。C 200。C
T4 135。C 135。C
T5 100。C 100。C
T6 85。C 85。C
The following table gives an overview of the ignition protection types covered by standards, and describes the basic principle
and the usual application cases. In addition to the normal data (manufacturer, type, serial No. electrical data), the data relating to
explosion protection must be included in the marking.
EXAMPLE Ex d Ⅱc T5
Explosion protected
electrical apparatus
Type ofprotection
(flame-proof enclosure)
Range of application
explosion protection
Temperature class
INFORMATION
(T5>100° C surface
TECHNICAL
temperature)
www.kukdongelecom.com..........13-17
TECHNICAL INFORMATION
7. Types of protection
Types of protection to IEC
Basis principle Schematic Applications
or European Standard
Increased A type of protection in which measures are applied so as Terminal and connection
Safety to prevent with a higher degree of security the possibility boxes control boxes housing
of excessive temperatures and of the occurance of
e excessive temperatures and of the external parts of
EX-modutes(of a different type
of protection) squirrel cage
IEC60079-7 electrical appartus which does not produce them in motors light fittings
normal sevice.
Non sparking Electrical equipment is not able to ignite a surrounding All items of electrical 0
Zone 2 The ignition types
explosive atmosphere (in the case of narmal operation equipment for zone 2 ; less
INFORMATION
Acetone, Industrial methane, Butyl alchol, Ethyl alcohol, Ethyl aceane, Methanol, Butane Proane,
Hexane, Ammonia, Blast furnace gas, carbon monoxide, Pentane, Heptane, Iso-octane Decane,
Benzene, Xylene, Xylene, Cyclohexane, Ethyl Methyl cetone, methyl Acetae, n-propyl Acetate n-Butyl
acetate, Amyl acetate, methylene, methylene chloride, Isobutanol, Amyl alcohol, Ethyl nitrite
Ⅱ B, Ethylene, Butadiene 1.3. Diethl ether, Ethylene, Town gas, Coke oven gas
Acroleine (or Bulyldiglycol) Essences speciales Fuel oil n。1(or Solvant paraffnique
Alcohol tetrahydro Butyldlgycol Terebenthin essence kerosene) (essences speclales)
furfurrique (or Buttylcarbitol) Ethoxyethanol n-Heptane Tetrafluoroethylene
T3 (200。C) Adehyde crotonique n-Butyraldehde Ethylcyclobutane n-Hexane Tetrahydrofuranne
Benzol diliuant Cyclohexane Ethylcyclohexxane Hydrogene sulfure Tetrahydrofurfurylique
n-Bromobutane Nettoyage essence Ethylcyclopentane Solvant(or nettoyage (Alcool)
Butylcarbitol (or solvant) Ethylmercaplan essence) White spirits
Acetaldehyde Acetique(Aldehyde) (pr ether butylique) Dioxanne Ethylique(Ether)
T4 (200。C) (or aldehyde acetique) Benzaldehyde Diethylether Ether ethylique Ethylmethylether
Aldehyde acelique Dibutylether (or ether ethyllique) (or diethylether) Trimethylamoe
T5 (100。C) Carbone(Sulfure)
INFORMATION
Ethy(Nitrite)
T6 (85。C)
TECHNICAL
ethyl Nitrite
www.kukdongelecom.com..........13-19
TECHNICAL INFORMATION
Temperature Code/Class
Maximum
ATEX Marking Example North America Cenelec, IEC
Surface Temp.°
Temp. Code Temp. Code
II 2 G Ex d IIC T6 F(°C)
842(450) T1 T1
572(300) T2
CE Mark Explosion Equipment Category Dust Explosion Method of Gas Group Temperature
Protected Group Protected Protection Code 536(280) T2A
500(260) T2B T2
446(230) T2C
419(215) T2D
Enclosure Protection
392(200) T3
NEMA IP Rating NEMA IP Rating
356(180) T3A
1 IP23 4X IP66 T3
329(165) T3B
2 IP30 6 IP67
320(160) T3C
3 IP64 12 IP55 275(135) T4
T4
4 IP66 13 IP65 248(120) T4A
212(100) T5 T5
General Requirements 185(85) T6 T6
CE Marking
Basic Requirements
Directives Equipment Groups
Electrical safety of equipment, Group Category Description
Low Voltage Directive
voltage ranges 50-1000AC, 75- Equipment intended for use in underground parts
73/23 EEC M1
1500DC. Ⅰ of mine or well, or surface installations of such
M2 mines.
EMC Directive Electromagnetic emissions
89/336 EEC and immunity. 1 Equipment intended for use in areas in which
Ⅱ 2 explosive atmospheres are caused by gases,
3 vapours, mists or air/dust mixtures.
ATEX Directive
Hazardous Area Equipment
94/9 EEC
Area Classification
Hazardous Locations Gas Groups Hazard Under
Continuous Intermittent
Abnormal conditions
Typical Gas North America CEC section Cenelecen 50014
Hazard 18, NEC Article 500 IEC 79-0 North America Division 1
Division2 or Zone2
(CEC/NEC) Zone 0 Zone1
Acetylene A or IIC IIC
CENELEC/IEC Zone 0 Zone1 Zone2
Hydrogen B or IIC IIC
www.kukdongelecom.com..........13-21
TECHNICAL INFORMATION
CERTIFICATION
TYPE OF APPROVED TYPE OF APPROVED
CERT NO MODEL DESCRIPTION CERT NO MODEL DESCRIPTION
PROTECTION AUTHORITIES PROTECTION AUTHORITIES
4 ELE/42501/3 NS2A-D CLASS "A" STERN LIGHT(TYPE ‖),DUAL RINA 57 EX21FLP745 PX-S25d Sodium Light(AC240V, 250W Max) Exde ‖B T2 IP66 KIMM
7 ELE/42501/8 NG-S1 RED FLASHING LIGHT RINA 60 EX21IP779 RCS-323 Reefer Container Socket(440V, 32A) IP67 KIMM
8 ELE/42501/7 NV-S1 MANEUVERING SIGNAL LIGHT RINA 61 EX21ICS804 IX-60ep Incandescent Portable Hand Lamp(60W) Ex e ‖ T3 IP66 KIMM
CLASS"A"MASTHEAD LIGHT
9 2001-003 NM2A-D (TYPE ‖), DUAL MOMAF 62 EX21ICS805 IXF-23ep Fluorescent Portable Hand Lamp(23W) Ex e ‖ T3 IP66 KIMM
12 2001-006 NS2A-D CLASS"A"STERN LIGHT(TYPE ‖), DUAL MOMAF 65 EX23IP901 FS220W Fluorescent Ceiling Light(20Wx1,20Wx2) IP67 KIMM
14 2001-014 NU2A-D CLASS"A"RED LIGHT(TYPE ‖), DUAL MOMAF 67 EX23IP903 FS220W1 Fluorescent Ceiling Light(20Wx1, 20Wx2) IP66 KIMM
CLASS"A"MASTHEAD LIGHT(TYPE ‖ ),
15 2001-009 NM2A-S SINGLE MOMAF 68 10945/A0 EC M. C. T B.V
19 2001-013 NA2A-S CLASS"A"WHITE LIGHT(TYPE ‖), SINGLE MOMAF 72 EX23IP901 FS220W KIMM
20 2001-014 NU2A-S CLASS"A"RED LIGHT(TYPE ‖), SINGLE MOMAF 73 EX23IP900 FS320W KIMM
23 2001-017 NG-S1 RED FLASHING LIGHT MOMAF 76 03-4419 FL. LIGHTING FIXTURES KS
24 2001-018 NH-S1 GREEN FLASHING LIGHT MOMAF 77 N/A PFH-30N Halogen Flood Light 한국조명기술연구소
25 2001-019 NV-S1 MANEUVERING SIGNAL LIGHT MOMAF 78 N/A PFSI-40N Sodium Flood Light 한국조명기술연구소
28 98-BK39885-X PX-I30d Explosion Proof Incand Flood Light Exde ‖C T4 ABS 81 EX25FLP103 FX-420d FL.Ceiling Light 40Wx2 Ex d IIC T6 KIMM
29 D/28916/A.1 MODULE "D" Production Quality Assurance Module : D B.V 82 EX25ICS104 FX-420ed FL.Light 40Wx2 Ex ed IIC T5 KIMM
31 1315 FX-220d Flameproof Type Fluorescent Ceiling Exd ‖C T6 N.k 84 EX25ICS106 IX-20d Incan. Light 20W Ex d IIC T5 KIMM
Light(220V 20W×2 Max)
32 EX20IP627 EL-32H Working Light IP66 KIMM 85 EX25ICS107 IX-00e Incan. Light 20W Ex e II T2 KIMM
33 EX20FLP633 KD-XPG9/11/13.5 Cable Gland EX d ‖C KIMM 86 EX25ICS108 PX-I30d Incan. Ceiling Light 300W Ex de IIC T4 KIMM
21/29/36/42
34 EX20ICS655 ELX-F32 Working Light Ex e ‖ T3 KIMM 87 EX25ICS109 PX-I50d Incan. Ceiling Light 500W Ex de IIC T4 KIMM
35 EX20FLP657 FX-220d Fluorescent Ceiling Light(20W×2) Ex d ‖C T6 KIMM 88 EX25ICS110 IXF-00d,IXF-60d Incan. Light 100W Ex de IIC T5 KIMM
36 EX20FLP658 FX-420D Fluorescent Ceiling Light(40W×2) FX-420d Ex d ‖C T6 KIMM 89 EX25ICS111 IXF-00d,IXF-60d Incan. Light 100W Ex de IIC T4 KIMM
37 EX20FLP659 Ix-20d Incandescent Light(20W) Ex d ‖C T5, IP67 KIMM 90 EX25ICS112 PXC-M40d Mercury Ceiling Light Ex d IIC T4 KIMM
38 EX20FLP660 IX-00d Incandescent Light(100W) Ex d ‖C T4 KIMM 91 EX25ICS113 PX-S40d Sodium Light 400W Ex de IIB T3 KIMM
39 EX20ICS661 FX-220e Fluorescent Ceiling Light(20W×2) Ex e ‖ T5 KIMM 92 EX25ICS114 PX-S15d Sodium Light 400W Ex de IIB T4 KIMM
40 EX20ICS662 ELX-F32 Working Light(32W) Ex e ‖ T6 KIMM 93 EX25ICS115 PX-H50d Halogen Flood Light 500W Ex de IIB T3 KIMM
41 EX21FLP682 PFS-42-13 Breather Drain Ex d ‖B KIMM 94 EX25ICS116 PX-H30d Halogen Flood Light 300W Ex de IIB T4 KIMM
42 EX21FLP693 PX-I30d Incandescent Flood ight(300W) Ex de ‖C T4 KIMM 95 EX25ICS117 PXC-S40d Sodium Light 20W Ex d IIC T4 KIMM
43 EX21FLP694 PXC-S40d Sodium flood Light(400w) Ex de ‖C T4 KIMM 96 EX25ICS118 EXBEL-20 Alarm Bell DC24V,AC240V,90db Ex d IIB T5 KIMM
44 2001.1019-Q1 ELX-F32 Working Light Exem ‖ T3 IP66 KOSHA 97 EX25ICS119 SX-21d SWITCH 16A Ex d IIC T6 KIMM
45 EX21FLP711 PX-S40d Sodium Light(400W Max) Exde ‖B T3 IP66 KIMM 98 EX25ICS120 JBX-125,JBX-95 Junction Box 30A Ex d IIC T6 KIMM
46 EX21FLP712 SX-21d Switch(16A,Max) Ex d ‖C T6 IP66 KIMM 99 EX25ICS121 CBX-B11ep Connection Box 30A Ex e IIC T6 KIMM
47 EX21FLP713 JBX-4d125 Junction Box Ex d ‖C T6 IP66 KIMM 100 EX25FLP166 IXI-00d B Incan. Ceiling Light 100W Ex d IIB T3 KIMM
JBX-4d95
48 EX21FLP714 KD-XNPT-00 Cable Gland(NPT 3/4") Ex d ‖C KIMM 101 EX26FLP038 IXF1-23d FL.Ceiling Light 23W Ex d IIB T5 KIMM
49 EX21ICS715 FX-420e Fluorescent Ceiling Light(40W×2) Ex e ‖ T5 IP66 KIMM 102 EX26ICS062 FX-420e FL.Ceiling Light 40Wx2 Ex e IIC T5 KIMM
INFORMATION
50 EX21ICS716 CBX-B11∼15eP Connection Box Ex e ‖ T6 IP65 KIMM 103 EX26ICS061 FX-220e FL.Ceiling Light 20Wx2 Ex e II T5 KIMM
TECHNICAL
51 EX21ICS717 IX-00eB Incandescent Light(AC240V. 60W. Max) Ex e ‖ T2 IP56 KIMM 104 EX25FLP102 FX-220d FL.Ceiling Light 20Wx2 Ex d IIC T6 KIMM
극동일렉콤주식회사
KUKDONG ELECOM CO., LTD. LOCAL AGENT
KOREA HEAD OFFICE & FACTORY
1509-12, DADAE-DONG, SAHA-GU, BUSAN, KOREA
TEL : + 82-51-266-0050 FAX : + 82-51-265-0985