8/1/2021 Fanuc 11T configuration document
FactoryWiz
Fanuc 11T configuration document
CNC Configuration Sheet
11T
CNC Parameters:
Setting screen:
Punch code- 1=ISO
TV CHECK=0 OFF
Under Service page:
0000 = xxx01000 (ISO)
0020 = 1 (Input device Foreground)
0021 = 1 (Output device Foreground)
0022 = 1 (Input device Background)
0023 = 1 (Output device Background)
5001 to 1 (Device Select)
5002 to 2 (RS232 Device
Select)
5110 to 3 (Device type DC Codes
used)
5111 to 1 (1 stop bit)
5112 to 10 (4800 baud)
11=9600, 9=2400, 8=1200 7=600 6=300
FactoryWiz DNC Settings:
Basic Communication
1.01- Port Type: Standard
1.11- Baud: 4800
1.12- Data Bits: 7
1.13- ASCII Even
1.14- Stop Bits: 1
1.15- Handshake:
XON/XOFF
Sending Options
2.11- Leader: %<10>
2.12- Trailer: %
2.23- Skip lines
that contain: %
2.31- Automatic timeout: 7
Receiving Options
1: O
3.11- Program identifier
3.12- Program Identifier 2: :
3.21- Receive timeout: 3
3.31- Ignore data before
first end-of-block: True
3.32- Ignore data after last end-of-block: True
Remote Commands
4.02- Request for file command: GET-
4.03- Request for file command (drip feed): DNC-
4:11- Request to save command: PUT-
Additional Notes:
Changing CNC Parameters:
System (Param) screen:
to MDI mode on machine.
To set parameters, move dial
Press SETTINGS key. Change PWE (#8000) to 1. The CNC
will alarm.
Outputting CNC Programs:
To output a program, set the CNC to "edit" mode. Press the PROG key on the control
panel. Use the right arrow (Page) key until PUNCH appears. Press PUNCH, then
1/2
8/1/2021
p g ( g ) yFanuc 11T configurationppdocument ,
Press THIS.
Inputting CNC Programs:
To input a program, set the CNC to "edit" mode. Press the PROG key on the control
panel. Use the right arrow(Page)keys until READ appears. Press READ, then press
ALL.
Wiring Diagram:
Pinout includes RTS/CTS Handshaking
DB-9 com port Wire color DB-25 CNC Jumper?
(Disconnected) Shield 1
2 (Receive Data) Green 2 (Transmit Data)
3 (Transmit Data) Red 3 (Receive Data)
5 (Signal Ground) Black 7 (Signal Ground)
7 (RTS) Brown 5 (CTS)
8 (CTS) Blue 4 (RTS)
6 (DSR) JUMPER
8 (DCD)
20 (DTR)
Refresh Your Memory, Inc. | 6920 Santa Teresa Blvd Suite 201 | San Jose, CA 95119
408.224.9167 | www.factorywiz.com
https://desk.zoho.com/portal/factorywiz/en/kb/articles/fanuc-11t-configuration-document