F64G - Olympian Plus Plug-In System

General purpose filter

>> Port size: 1/4” ... 3/4” >> Quick release bayonet
(ISO G/PTF) bowl
>> Effective liquid removal
and positive solid
filtration
>> Large filter element
area for minimum
pressure drop

Technical features
Medium: Drain: Service life indicator: Materials:
Compressed air only Manual or automatic Without (standard) Body and yoke: Zinc alloy
Maximum operating pressure: Automatic drain conditions: With on request Connection piece: Aluminium
17 bar (246 psi) Pressure to close drain: Bowl size: Metal bowl: Aluminium
Filter element: > 0,3 bar (4.3 psi) 0,2 litre (7 fluid oz) Prismatic liquid level indicator:
40 μm (standard) 5 μm (optional) Pressure to open drain: Ambient/Media temperature: Grilamid
Flow: < 0,2 bar (2.9 psi) -20° ... +80°C ( -4° ... +176°F) Filter element: Sintered plastic
See diagrams on page 2 Minimum air flow to close drain: Air supply must be dry enough to Element: Sintered bronze or plastic
Port sizes: 0,6 dm3/s (1.3 scfm) avoid ice formation at temperatures Elastomers: NBR
1/4”, 3/8”, 1/2” or 3/4” below +2°C (+35°F).

Technical data, standard models


Symbol Port size Size Filter element Flow * Bowl Drain Weight Model
(µm) (dm3/s) (kg)
G1/4 — 40 33 Metal Manual 1,42 F64G-2GN-MD3
G3/8 — 40 66 Metal Manual 1,42 F64G-3GN-MD3
G1/2 Basic 40 75 Metal Manual 1,32 F64G-4GN-MD3
G3/4 — 40 75 Metal Manual 1,72 F64G-6GN-MD3
Without yoke — 40 — Metal Manual 0,92 F64G-NNN-MD3
G1/4 — 40 33 Metal Automatic 1,42 F64G-2GN-AD3
G3/8 — 40 66 Metal Automatic 1,4 F64G-3GN-AD3
G1/2 Basic 40 75 Metal Automatic 1,37 F64G-4GN-AD3
G3/4 — 40 75 Metal Automatic 1,73 F64G-6GN-AD3
Without yoke — 40 — Metal Automatic 0,94 F64G-NNN-AD3
* Typical flow with 10 bar (145 psi) inlet pressure, and 6,3 bar (91 psi) set pressure and 0,5 bar (7.2 psi) drop from set.

Option selector F64G-˙˙˙-˙D˙


Port size Substitute Element Substitute
1/4” 2 5 μm 1
3/8 “ 3 40 μm (standard) 3
1/2 “ 4 Drain Substitute
3/4“ 6 Automatic A
Without yoke (standard) N Manual M
Threads form Substitute Service life indicator Substitute
PTF A Mechanical D
ISO G (standard) G Without (standard) N
Without yoke (standard) N

Our policy is one of continued research and development. We therefore reserve the right to amend, 02/16
without notice, the specifications given in this document. (1997 - 8070d) © 2015 IMI International s.r.o. en 8.240.100.01
F64G - Olympian Plus Plug-In System
General purpose filter

Flow characteristics
Port size: 1/2”; Filter element 40 µm
Inlet pressure bar (psi)
psi

bar

2,5 4,0 6,3 8,0 10,0


(36) (58) (91) (116) (150)
0,6
8

6 0,4
Pressure drop ∆p

0,2
2

0 0
0 20 40 60 80 dm3/s

0 40 80 120 160 200 scfm


Air flow

Our policy is one of continued research and development. We therefore reserve the right to amend, 
en 8.240.100.02 without notice, the specifications given in this document. (1997 - 8070d) © 2015 IMI International s.r.o. 02/16
F64G - Olympian Plus Plug-In System
General purpose filter

Accessories and service kit

Accessories
Models with G-thread 3/2 Shut-off valve End connector Rear entry
Single yoke Double yoke Threaded inlet only Threaded outlet only kit bracket kit

1 2 3Thread4 5 6 7 8 9 10 1 2 3 41 52 63 74 85 96 10
7 8
1 12 13G1/4 14 15 16
Y64A-2GA-N1N 17 18Y64A-2GA-N2N
19 20 T64T-2GB-P1N 11 12
T64T-2GC-P1N 13 14
11 15
12
— 16
13 17
14 —18
15 19
16 20
17 18
G3/8 Y64A-3GA-N1N Y64A-3GA-N2N T64T-3GB-P1N T64T-3GC-P1N — —
0 21 22G1/2 23 24 25
Y64A-4GA-N1N 26 27Y64A-4GA-N2N
28 29 T64T-4GB-P1N 20 21
T64T-4GC-P1N 22 23
20 24
21 25
74505-5022 26
23 —27
24 28
25 29
26 27
G3/4 Y64A-6GA-N1N* Y64A-6GA-N2N* T64T-6GB-P1N T64T-6GC-P1N 74505-53 18-026-981
0 31 32 33 34 35 36 37 38 39 30 31 32 30
33 34
31 35
32 36
33 37
34 38
35 39
36 37
1/4 PTF Y64A-2AA-N1N Y64A-2AA-N2N T64T-2AB-P1N T64T-2AC-P1N — —
3/8 PTF Y64A-3AA-N1N Y64A-3AA-N2N T64T-3AB-P1N T64T-3AC-P1N — —
1/2 PTF Y64A-4AA-N1N Y64A-4AA-N2N T64T-4AB-P1N T64T-4AC-P1N 74505-52 —
3/4 PTF Y64A-6AA-N1N* Y64A-6AA-N2N* T64T-6AB-P1N T64T-6AC-P1N 74505-55 —
*These yokes are supplied with two end connenctor kits as standard.

Bracket mounting Nut Yoke connector kit Porting block Adjustable pressure Padlock with
switch two keys

1 2 1 1 3 2 2 4 3 3 5 4 4 6 5 5 7 6 6 8 7 7 9 8 810 9 9 1010
11 1274504-50
1111131212141313151414161515171616181717
74502-89 191818201919 202074507-50
74503-51 4346-99 0613633 (brass)

20 212020222121
Service 232222242323252424262525272626282727292828 2929
kit
30 31Service
30303231kit 33
31 323234333335Service
Automatic drain
34343635kit 37
35 3636383737393838 3939
Manual drain

F64G-KITA40 F64G-KITM40

Our policy is one of continued research and development. We therefore reserve the right to amend,
02/16 without notice, the specifications given in this document. (1997 - 8070d) © 2015 IMI International s.r.o. en 8.240.100.03
F64G - Olympian Plus Plug-In System
General purpose filter

Basic dimensions Dimensions in mm


Projection/First angle

23
37 2

5 or 3/16”
7
171

186
224 #

239 #

4
18,5

33,5

Manual drain ø6

Automatic drain
3 157
105 # Minimum clearance required to remove bowl
1 Main ports 1/4”, 3/8”, 1/2” or 3/4”
2 Service indicator optional
3

3 For main ports 3/4” only


4 Sight glass
ø33
58
74

7 Gauge port 1/8”

1 15 1

Single yoke with bracket mounting Double yoke with bracket mounting
223
143
194
114
30,5
30,5
110
93

110
93
8,2

8,2

2,8
2,8
14,5
14,5 57 80
2
48

2
48
85

85

Our policy is one of continued research and development. We therefore reserve the right to amend, 
en 8.240.100.04 without notice, the specifications given in this document. (1997 - 8070d) © 2015 IMI International s.r.o. 02/16
F64G - Olympian Plus Plug-In System
General purpose filter

Rear entry bracket Porting block Dimensions in mm


Projection/First angle
18-026-981 74507-50

A A 41
ø 22
68,5
G 3/4
35,8
29,5

50
59 G3/8

24
8 +0,2 7,5

41,5
35
20,5 54,5
41,5 83,5
G1/4
A-A 1

1 ‘O’-ring (included in scope


of supply of bracket)
2

Adjustable pressure switch


4346-99 Pg 7
Voltage

6
24 V d.c./240 V a.c.
Current 0,5 A (d.c.); 5 A (a.c.)
Pressure range 2 ... 10 bar 6

61
Repeatabillity 2% of full set point range at 20°C 71

Average deadband 0,8 ... 1,7 bar

25
Electrical connection EN 175301-803 - Form C, 15 mm
(corresponding to choosen coil)

24
Degee of protection: IP65
59 ø 22
Adjustable Standard
41
Material Body: Aluminium, Elastomers: NBR

6 Adjusting screw

3/2 Shut-off valve 73 B


Symbol A B øC Model
G1/4 48 27 T64T-2G*-P1N 7 OPEN
2
G3/8 48 27 T64T-3G*-P1N
G1/2 48 27 T64T-4G*-P1N
68

1 3
øC

G3/4 51 33 T64T-6G*-P1N
A

* B = Threaded inlet only, C = Threaded outlet only


Rc 1/8 13,5
17 27,5

7 Padlock hole ø7,5 mm

Warning
EN
These products are intended for use in industrial compressed air The system designer is warned to consider the failure modes of all
systems only. Do not use these products where pressures and component parts used in fluid power systems and to provide adequate
temperatures can exceed those listed under safeguards to prevent personal injury or damage to equipment in the
»Technical features/data«. event of such failure.
Before using these products with fluids other than those specified, System designers must provide a warning to end users in the system
for non-industrial applications, life-support systems or other instructional manual if protection against a failure mode cannot be
applications not within published specifications, consult adequately provided.
IMI Precision Engineering, IMI International s.r.o. System designers and end users are cautioned to review specific
Through misuse, age, or malfunction, components used in fluid warnings found in instruction sheets packed and shipped with these
power systems can fail in various modes. products.

DE Our policy is one of continued research and development. We therefore reserve the right to amend,
02/16 without notice, the specifications given in this document. (1997 - 8070d) © 2015 IMI International s.r.o. en 8.240.100.05
Diese Produkte sind ausschließlich in Druckluftsystemen zu verwenden. systemen verwendete Komponenten auf verschiedene Arten versagen.
Sie sind dort einzusetzen, wo die unter »Technische Merkmale/-Daten« Systemauslegern wird dringend empfohlen, die Störungsarten aller

You might also like