Critical Power 2017 Catalogue: UPS For Process and Service Industry
Critical Power 2017 Catalogue: UPS For Process and Service Industry
POWER GUARDIAN 10
Single phase UPS monitoring software
ECS 10-160 kVA 3/1 and 3/3 phase E8000 ECS - INGENIO ECS 39
Emergency Central Systems for emergency lighting,
fire fighting and safety equipment according to EN 50171
STS 16-32 A 1/1 phase STS RACK 44
Rackmount Static Transfer Switches for networks and servers, data centers,
industrial control and process automation
STS 100-3000 A 3/3 phase STS 300 46
Centralized Static Transfer Switches for networks and servers, data centers,
industrial control and process automation
GUARDIAN NET 48
Remote Diagnostics and Preventive Monitoring
Borri Service 50
1
Who we are
Borri Group is a global provider of power
electronics systems and solutions for harsh
industrial and demanding commercial
and ICT secure power requirements
merging eighty years of experience in
developing, manufacturing and supplying
uninterruptable power systems and
solutions.
The Research and Development Team’s
expertise combines AC and DC power
technologies spanning the worlds of
both conventional and renewable energy,
to provide innovative solutions for
tomorrows problems.
The company is comprised of three
business units: Industrial Power,
Critical Power and Renewable Power,
headquartered in Bibbiena, Italy.
Borri’s latest products, based on Green
Conversion operation, guarantee the best
PUE for green data centers: proof of the
ongoing company commitment to
innovation.
Thanks to its highly skilled custom
engineers Borri controls in-house the
entire process: from feed studies to design,
production and after-sales service
guaranteeing state-of-the-art solutions.
Based in Italy with over 15,000 m²
production area and a large high power
test field, Borri can depend on its
more than 80 years of experience and
multidisciplinary research and
development to serve our customers best.
Applications Highlights
• Home Office • User-friendly and Plug and Play
• Computers and peripherals • Compact and noiseless
• Networks and servers • Intuitive LCD display
• Small data centers • Rack/Tower convertible design
• Parallel redundant configuration
3
GIOTTO
1ph from 450 to 2000 VA
Line-interactive UPS
for Home Office,
computers and peripherals
Features and benefits ● Audible alarm alerts upon utility power
and UPS status change.
● User-friendly UPS ensuring compact ● Easy User-replaceable battery.
protection for a wide range of needs: ● AVR technology stabilizing output
• Best power protection for PC from voltage to protect your electronics over a
450 to 850 VA with one output wide range of mains quality issues.
receptacle (IEC 320-C13) and one
● Advanced battery management
Schuko.
extending battery life.
• Advanced power protection from
● Internet Modem / LAN protection via
1000 to 2000 VA with four output
receptacles (IEC 320-C13) and one RJ-11/45 plug.
Schuko for high performance PC and ● USB communication port providing UPS
peripherals. managements.
● Instantaneous battery back-up power ● Cold start for powering loads when
and electrical interference protection. mains are not available.
● Plug and Play installation easy to set up ● Borri Power Guardian user-friendly UPS
also for first-time users. management software free
● Compact and noise-free running to be
downloadable at www.borri.it/download
placed anywhere at home or office. (for more info see p.10).
● Energy efficient ensuring lowest impact
on energy costs.
● Intuitive LCD display provides
easy-to-read UPS status and power
information.
0 2 4 6 8 10 12 14
2000 VA
1500 VA
1000 VA
850 VA
650 VA
450 VA
4
GIOTTO technical data
Rating (VA) 450 650 850 1000 1500 2000
Nominal power (W) 270 380 500 600 900 1200
UPS dimensions WxDxH (mm) 100x292x140 148x315x198
UPS weight (kg) 4 5 5.5 9 10.5 11.8
Input
Connection type IEC 320-C14
Nominal voltage 230 Vac 1-phase
Voltage range 160 to 290 Vac
Frequency and range 50/60 Hz, 45 to 65 Hz
Output
Connection type 1 IEC 320-C13 and 1 Schuko 4 IEC 320-C13 and 1 Schuko
Nominal voltage 230 Vac 1-phase
Frequency 50/60 Hz
Waveform Simulated sine wave
Battery
50% load 8 10 11 13 8 9
Autonomy time (min) ◆
100% load 3 3 3 3 3 3
Connectivity and function extensions
Front panel LCD, ON/OFF button
Included: USB.
Communication
Compatible platforms: Windows, Linux, Mac
Environmental
Operating temperature range 0°C to +40°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1m (dBA) <40
Standards and certifications
Quality assurance, environment,
health and safety ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007
5
GALILEO
1ph from 1000 to 3000 VA
On-line UPS
for networks and servers
Features and benefits ● Active harmonic power quality control
ensuring up to 0.99 input PF and
● On-line double conversion UPS from THDi<3% for maximum compatibility
1000 to 3000 VA, Tower and 2U with sources.
Rack/Tower from three to six output ● Automatic self test and advanced battery
receptacles (IEC 320-C13) and one or management maximizing battery
two Schuko. performance and extending battery life.
● Rack/Tower convertible design to ● Battery extension box allowing
protect your investment when migrating additional autonomy time to be quickly
from tower to rack-mount environment. added.
Both UPS and display panel can be ● Remote power off for immediate UPS
rotated. shutdown in case of emergency.
● Easy installation and set up,
● USB communication port providing UPS
user-replaceable and upgradable management.
battery.
● One slot auto-sensing communication
● Intuitive LCD display providing
cards.
easy-to-read UPS status and power
● Cold start for powering loads when
information.
mains are not available.
● Audible alarm alerts upon utility power
● Borri Power Guardian user-friendly UPS
and UPS status change.
management software with alerts upon
● Smart cooling system ensuring further
main power failures and system shutdown
energy savings. notification via SMS and email, free
● Programmable switched outlet group for downloadable at www.borri.it/download
setting load priorities. (for more info see p.10).
Main options
● SNMP card to send UPS status to BMS’s
by Ethernet connection and SNMP
Autonomy time in minutes for Rack/Tower UPS or ModBus over IP protocol to monitor
UPS status by any internet browser from
0 10 20 30 40 50 60 70 80 workstations and to receive SMS or
e-mail alerts from the UPS on any
portable device.
3 kVA ● Contact relay card to send UPS status to
PLC’s, SCADA’s or AS400’s by voltage
free SPDT contacts.
2 kVA ● Additional battery charger for external
battery box.
● Rail kit Rack/Tower.
1 kVA ● Rack
PDU with external sockets and
manual bypass switch.
0 10 20 30 40 50 60 70 80
3 kVA
2 kVA
1 kVA
6
GALILEO technical data
UPS Type T* T* T* RT (2U)** RT (2U)** RT (2U)**
Rating (VA) 1000 2000 3000 1000 2000 3000
Nominal power (W) 900 1800 2700 900 1800 2700
UPS dimensions WxDxH (mm) 144x367x236 151x444x322 189x444x322 440x390x88 440x475x88 440x600x88
UPS weight (kg) 11.2 18.8 24.9 12.0 17.0 26.5
Input
Connection type IEC 320-C14 IEC 320-C20 IEC 320-C14 IEC 320-C20
Nominal voltage 230 Vac 1-phase
Voltage range 195 to 260 Vac
Frequency and range 50/60 Hz, 45 to 65 Hz
Power factor 0.98 0.99
Current distortion (THDi) <3%
Output
3 IEC 320-C13 3 IEC 320-C13 6 IEC 320-C13
Connection type 3 IEC 320-C13 6 IEC 320-C13
1 Schuko 2 Schuko 2 Schuko
Nominal voltage 230 Vac +/-1% 1-phase
Frequency 50/60 Hz
Power factor Any power factor up to 0.9 lagging or leading without power derating
Overload capability 105% continuous, 120% for 30 seconds, 150% for 10 seconds, >150% transfer to bypass
Mode of operation On-line, Eco mode
Battery
GALILEO RT 1 kVA
7
LEONARDO
1ph from 6 to 10 kVA
On-line UPS
for networks and servers,
small data centers Remote emergency power off to
Features and benefits ●
guarantee your piece of mind in critical
● On-line double conversion UPS from 6 to applications.
10 kVA, Tower and 2U or 3U Rack/Tower. ● Internal manual bypass for safe and easy
● Parallel redundant configuration maxi- maintenance.
mizing the availability. ● RS232 communication port providing
● Rack/Tower convertible design to UPS management.
protect your investment when migrating ● Two slots auto-sensing communication
from tower to rack-mount environment. cards.
Both UPS and display panel can be ● Cold start for powering loads when
rotated. mains are not available.
● Easy installation and set up, user-repla- ● Borri Power Guardian user-friendly UPS
ceable and upgradable battery. management software with alerts upon
● Intuitive LCD display providing easy-to- main power failures and system shutdown
read UPS status and power information. notification via SMS and email, free
● Audible alarm alerts upon utility power downloadable at www.borri.it/download
and UPS status change. (for more info see p.10).
● Smart cooling system ensuring further
energy savings. Main options
● Active harmonic power quality control ● SNMP card to send UPS status to BMS’s
ensuring 0.99 input PF and THDi<3% for by Ethernet connection and SNMP
maximum compatibility with sources. or ModBus over IP protocol to monitor
● Automatic self test and advanced battery UPS status by any internet browser from
management maximizing battery workstations and to receive SMS
performance and extending battery life. or e-mail alerts from the UPS on any
● Battery extension box allowing additional portable device.
autonomy time to be quickly added. ● Contact relay card to send UPS status to
PLC’s, SCADA’s or AS400’s by voltage
Autonomy time in minutes for Rack/Tower UPS free SPDT contacts.
● Additional battery charger for external
battery box.
0 10 20 30 40 50 60 70 80
● Parallel kit.
10 kVA
0 10 20 30 40 50 60 70 80
10 kVA
6 kVA
8
LEONARDO technical data
UPS Type T* T* RT (2U)*** RT (4U)** RT (3U)***
Rating (kVA) 6 10 6 6 10
Nominal power (kW) 5.4 9 5.4 5.4 9
UPS dimensions WxDxH (mm) 290x645x748 290x645x748 440x680x88 440x680x176 440x680x132
UPS weight (kg) 86 96 24 52 26
Input
Connection type Hardwired 2w (rectifier), 2w (bypass) Hardwired 2w
Nominal voltage 230 Vac 1-phase
Voltage range 160 to 280 Vac
Frequency and range 50/60 Hz, 45 to 65 Hz
Power factor 0.99
Current distortion (THDi) <6%
Output
Connection type Hardwired 2w
Nominal voltage 230 Vac +/- 1% 1-phase
Frequency 50/60 Hz
Power factor Any power factor up to 0.9 lagging or leading without power derating
Overload capability 104% continuous, 150% for 160 seconds, >150% transfer to bypass
Mode of operation On-line, Eco-mode
Battery
*Tower with internal battery **Rack/Tower with internal battery ***Rack/Tower without internal battery ◆ Measurement conditions: optimized parameters, fully charged battery, 0.7 PF
9
POWER
GUARDIAN
Single phase UPS
monitoring software
Borri Power Guardian is a free user-friendly
UPS software, providing automatic safe
Features and benefits
system shutdown upon power outages and ● Fast, easy installation and configuration
monitoring the UPS status. via USB or RS232 even for first-time users.
● Automatic orderly application and
system shutdown.
● Preventing potential data corruption and
hardware damage.
● Alerts on main power failures and
system shutdowns notification via SMS
and email.
● Automatic self-test of UPS and battery
status ensuring early detection of
anomalies.
● UPS parameters and power status at a
glance. It summarizes graphically
and numerically power problems such
as blackouts or electrical noise over time
and UPS information such as input and
output voltage, frequency, temperature,
loads and battery capacity.
● Customized settings for tailor-made
solutions.
● Available for MAC and Microsoft
operating systems (complete list at
www.borri.it/download).
● Download Borri Power Guardian free
software at www.borri.it/download.
10
B8031FXS - B8033FXS
Uninterruptible Power Supply
1ph - 3ph from 10 to 20 kVA
Applications Highlights
• Networks and servers • On-line double conversion
• Industrial control and process • Transformer free
automation • Full IGBT technology
• Building automation • Paralleling up to 120 kVA
11
B8031FXS
B8033FXS
Uninterruptible Power Supply
1ph - 3ph from 10 to 20 kVA
Features and benefits Main options
● High double conversion efficiency and ● Isolation transformer.
ECO mode for low running costs and ● Transformers/autotransformers for
environmental impact. voltage adjustment.
● Transformer free design for light small
● Battery voltage temperature
size layout. compensation.
● Removable power modules architecture
● External maintenance bypass
and built-in diagnostics for easy wall-mounted box.
maintenance and very low MTTR.
● Battery fuse switch wall-mounted box.
● Hot connection/disconnection of
parallel units for easy system resizing. ● Associatedbattery cabinets for long
autonomy times.
● Full IGBT technology and electronic
PFC, ensuring 0.99 input PF and ● Parallel kit for load sharing.
low THDi for maximum upstream ● Load-sync for single UPS units.
sources compatibility.
● Input
terminals for remote EPO, external
● Wide range of configurations with manual bypass auxiliary contact,
internal batteries for low TCO compact diesel mode.
solutions.
● Separate bypass input for B8033FXS.
● High power battery charger, suiting
● Cold start.
long autonomy applications.
● Dual DSP plus microcontroller logics for
top performance and reliability.
● CAN-bus based distributed parallel
control ensuring high load sharing
accuracy and no single point of failure.
● Comprehensive set of communication
options for total remote monitoring of
equipment operation.
● Included bypass contactor for
complete backfeed protection and
operators’ safety without additional
installation costs.
● Fully compliant with all international
product standards for maximum quality
guarantee.
0 5 10 15 20 25 30 35 40 45 50
20 kVA
15 kVA
10 kVA
12
B8031FXS - B8033FXS technical data
Rating (kVA) 10 15 20
Nominal power (kW) 9 13.5 18
UPS dimensions WxDxH (mm) 450x670x1200
UPS weight (kg) 100 110 110
UPS weight with internal
Max.285 Max.275 Max.275
battery (kg)
External battery module
500x670x1200
dimensions WxDxH (mm)
Battery configuration
Internal or external, 360 to 372 cells, VRLA (other options)
Max autonomy with int. battery 70% load (min) 49 24 12
Input B8031FXS (10-15-20 kVA) B8033FXS (10-15-20 kVA)
Other features
Environmental
UPS operating temperature range 0°C to +40°C
UPS storage temperature range -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) <52
Standards and certifications
Quality assurance,
ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007
environment, health and safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environmental aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3
Protection degree IEC 60529
Marking CE
13
B8031FXS - B8033FXS series options
Description When do I use it
LOAD A LOAD B
Included
TRANSFORMER 1-phase output isolation transformer for B8031FXS To galvanically isolate UPS from load or to
OUTPUT
QRA in extended cabinet change system’s earth arrangement
TRANSFORMER CABINET
3-phase input isolation transformer for B8033FXS To galvanically isolate UPS from load or to
in extended cabinet change system’s earth arrangement
Battery fuse switch in wall-mounted box To disconnect and protect an external battery pack
Input terminal block for external manual bypass When there is an external maintenance bypass switch,
switch auxiliary contact for state monitoring
Input terminal block for external battery switch When there is an external battery switch,
auxiliary contact for state monitoring
Included
14
INGENIO COMPACT
Uninterruptible Power Supply
3ph from 10 to 20 kVA
Applications Highlights
• Networks and servers • On-line double conversion
• Small and medium data centers • Transformer free
• Telecommunication • Full IGBT technology
• Parallel redundant configuration
• Built-in batteries
15
INGENIO
COMPACT
Uninterruptible Power Supply
3ph from 10 to 20 kVA
Features and benefits Main options
● On-line double conversion mode for ● Isolation transformer.
total load protection. ● Transformers/autotransformers for
● ECO mode for low running costs and voltage adjustment.
environmental impact. ● Battery voltage temperature
● Full rated output power, ensuring compensation.
optimal UPS sizing and utilization. ● External maintenance
● Transformer free design for light small bypass wall-mounted box.
size layout.
● External battery cabinets for long
● Full IGBT technology and electronic autonomy times.
PFC, ensuring 0.99 input PF and
● Parallel kit.
low THDi for maximum upstream
sources compatibility. ● Common battery.
● Wide input voltage range to save
battery life.
● Wide range of configurations with
internal and external batteries for low
TCO compact solutions.
● Parallel-redundant up to six units, to
increase system redundancy.
● Innovative design allows for fast
installation.
● Removable tray design for easy battery
maintenance.
● Comprehensive set of communication
options for total remote monitoring of
equipment operation.
● Fully compliant with all international
product standards for maximum quality
guarantee.
0 2 4 6 8 10 12 14 16 18 20
20 kVA
10 kVA
16
INGENIO COMPACT technical data
Rating (kVA) 10 20
Nominal power (kW) 10 20
UPS dimensions WxDxH (mm) 440x800x800
UPS weight (kg) 75 76
UPS weight with internal battery (kg) 150 165
External battery module
500x650x1200
dimensions WxDxH (mm)
Battery configuration Internal (standard): 180 cells; external: 156/240 cells Internal (standard): 216 cells; external: 192/240 cells
Input
Connection type Hardwired 4w
Nominal voltage 400 Vac 3-phase with neutral
Voltage tolerance -20%, +15% (rectifier); ±10% (bypass)
Frequency and range 50/60 Hz, 40 to 70 Hz
Power factor 0.99
Current distortion (THDi) <3%
Output
Connection type Hardwired 4w
Nominal voltage 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Power factor 1
Overload capacity 110% for 60 min, 125% for 10 min, 150% for 1 min
Efficiency (AC/AC)* Up to 98%
Connectivity and function extensions
Front panel
Touch screen display
Included: serial RS232; backfeed protection monitoring contact, remote EPO contact.
Remote communication
Optional: 2 slots for SNMP adapter, ModBus-RTU, contact relay card
Isolation transformer; transformers/autotransformers for voltage adjustment;
Optional function extensions external maintenance bypass; custom battery cabinets; wall-mounted battery fuse switch box;
battery thermal probe; parallel kit; other options on request
System
Protection degree IP 20
Colour RAL 9005
Installation layout 30 cm wall-gap
Accessibility Positioning casters; bottom cable entry
Other features
Environmental
UPS operating temperature range 0°C to +40°C
UPS storage temperature range -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) <52
Standards and certifications
Quality assurance,
ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007
environment, health and safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environmental aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3
Protection degree IEC 60529
Marking CE
17
INGENIO COMPACT series options
Description When do I use it
Included
18
INGENIO PLUS
Uninterruptible Power Supply
3ph from 30 to 160 kVA
Applications Highlights
• Small and medium data centers • On-line double conversion
• Networks and servers • Transformer free
• Industrial control and process • Full IGBT technology
automation • Paralleling up to 960 kVA
• Medical equipment
• Building automation
19
INGENIO
PLUS
Uninterruptible Power Supply
3ph from 30 to 160 kVA
Features and benefits Main options
● Green Conversion technology, high ● Isolation transformer.
efficiency even at light load and the
lowest TCO in its category. ● Transformers/autotransformers
for isolation or voltage adjustment.
● Full rated output power, ensuring optimal
UPS sizing and utilization. ●Battery voltage temperature
compensation.
● Transformer free design for compact,
light and sustainable systems. ● External maintenance bypass
wall-mounted box.
● Full IGBT technology and electronic PFC,
ensuring 0.99 input PF and THDi<3% for ● Battery fuse switch wall-mounted box.
maximum upstream sources compatibility. ●Battery cabinets for long autonomy
● Internal
battery configurations times.
up to 80 kVA for less floor space and ● Parallel kit for load sharing.
maximum flexibility.
● Load-sync for single UPS units, load-sync
● Dynamic Charging Mode (DCM) for box for two sets of paralleled UPS.
maximum versatility in long autonomy
and low charging time applications. ● Common battery.
● Green Conversion Battery Care (GCBC), ● Tripping coil for bypass disconnector.
for extended battery service life.
● Separate rectifier and bypass input for
● Comprehensive set of communication INGENIO PLUS 30-40 kVA.
options for total remote monitoring of
equipment operation. ● Ultra High Efficiency Mode (UHE).
0 5 10 15 20
80 kVA
60 kVA
40 kVA
30 kVA
20
INGENIO PLUS technical data
Rating (kVA) 30 40 60 80 100 125 160
Nominal power (kW) 30 40 60 80 100 125 160
UPS dimensions WxDxH (mm) 460x650x1230 560x940x1800
UPS weight (kg) 120 140 250 300 320 360 380
UPS weight with int. battery (kg) 365 385 800 850 - - -
Internal or external, 360 to 372 cells,
Battery configuration External 360 to 372 cells, VRLA (other options)
VRLA (other options)
Max autonomy with int. battery
11 7 16 11 - - -
70% load (min)
Input
Connection type Hardwired 4w Hardwired 4w (rectifier), 4w (bypass)
400 Vac 3-phase with neutral (rectifier)
Nominal voltage
380/400/415 Vac 3-phase with neutral (bypass)
Voltage tolerance -20%, +15% (rectifier); ±10% (bypass)
Frequency and range 50/60 Hz, 45 to 65 Hz
Power factor >0.99
Current distortion (THDi) <3%
Output
Connection type Hardwired 4w
Nominal voltage 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Static: ±1%;
Voltage regulation
dynamic IEC/EN 62040-3 Class 1
Power factor Up to 1, without power derating
Inverter: 125% for 10 min, 150% for 30 s, >150% for 0.1 s;
Overload capacity*
bypass: 150% continuous, 1000% for 1 cycle
Efficiency (AC/AC)** Up to 99%
Classification as per
VFI-SS-111
IEC/EN 62040-3
Connectivity and function extensions
Front panel Graphic display, mimic LED panel and keyboard, local EPO
Included (30 to 160 kVA): backfeed protection monitoring contact.
Included (60 to 160 kVA): serial RS232 and USB; input terminal block (remote emergency power off,
battery circuit breaker aux. cont. external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont.).
Remote communication
Optional: SNMP adapter (Ethernet), Web interface (Ethernet), ModBus-TCP/IP (Ethernet), ModBus-RTU (RS485),
from ModBus-RTU to PROFIBUS DP adapter; SPDT contact relay board; remote system monitoring panel;
UPS managing and server shutdown software
Isolation transformer; transformers/autotransformers for voltage adjustment;
Optional function extension external maintenance bypass; custom battery cabinets; wall-mounted battery fuse switch box;
battery thermal probe; parallel kit, load-sync for single UPS and load-sync box (2 UPS systems); other options on request
System
Protection degree IP 20
Colour RAL 9005
10 cm wall-gap, Wall and side by side installation allowed,
Installation layout
side by side installation allowed 80 cm clearance on one side only with internal battery
Front and top access,
Accessibility Front access, side access (only with internal battery), bottom cable entry
bottom cable entry
Other features
*conditions apply **according to IEC/EN 62040-3
Environmental
UPS operating temperature range 0°C to +40°C
UPS storage temperature range -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) <60
Standards and certifications
Quality assurance,
ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007
environment, health and safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environmental aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3
Protection degree IEC 60529
Marking CE
21
INGENIO PLUS series options
Description When do I use it
LOAD A LOAD B
LOAD SYNC
To synchronize the output of two paralleled UPS systems
BOX Load-sync box for two sets of paralleled UPS for no-break load transfers by
downstream static transfer switches
LOAD A LOAD B
Battery fuse switch in wall-mounted box To disconnect and protect an external battery pack
Input terminal block for external manual bypass When there is an external maintenance bypass switch,
switch auxiliary contact for state monitoring
Input terminal block for external battery switch When there is an external battery switch,
auxiliary contact for state monitoring
22
INGENIO MAX
Uninterruptible Power Supply
3ph from 200 to 300 kVA
Applications Highlights
• Medium data centers • On-line double conversion
• Networks and servers • Transformer free
• Industrial control and process • Full IGBT technology
automation • Paralleling up to 1.8 MVA
• Medical equipment
• Building automation
23
INGENIO
MAX
Uninterruptible Power Supply
3ph from 200 to 300 kVA
Features and benefits Main options
● Three level Green Conversion, up to ● Transformers/autotransformers for
97% system efficiency, very low noise isolation or voltage adjustment.
and the lowest TCO in its category.
● Battery voltage temperature
● Full rated output power, ensuring optimal compensation.
UPS sizing and utilization.
● External maintenance bypass
● Transformer free design for compact, wall-mounted box.
light and sustainable systems.
● Battery fuse switch wall-mounted box.
● Full IGBT technology and electronic PFC,
ensuring 0.99 input PF and THDi<3% ● Battery cabinets for long autonomy times.
for maximum upstream sources ● Parallel kit for load sharing.
compatibility.
● Load-sync for single UPS units, load-sync
● Dynamic Charging Mode (DCM) for
box for two sets of paralleled UPS.
maximum versatility in long autonomy
and low charging time applications. ● Load Based Shutdown (LBS) for parallel
units.
● Green Conversion Battery Care (GCBC),
for extended battery service life. ● Common battery.
95%
90%
85%
Battery life %
GCBC float charge
24
INGENIO MAX technical data
Rating (kVA) 200 250 300
Nominal power (kW) 200 250 300
UPS dimensions WxDxH (mm) 850x950x1975
UPS weight (kg) 720 850 930
Battery configuration External 360 to 372 cells, VRLA (other options)
Input
Connection type Hardwired 4w (rectifier), 4w (bypass)
400 Vac 3-phase with neutral (rectifier)
Nominal voltage
380/400/415 Vac 3-phase with neutral (bypass)
Voltage tolerance -20%, +15% (rectifier); ±10% (bypass)
Frequency and range 50/60 Hz, 45 to 65 Hz
Power factor >0.99
Current distortion (THDi) <3%
Output
Connection type Hardwired 4w
Nominal voltage 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Static: ±1%;
Voltage regulation
dynamic: IEC/EN 62040-3 Class 1
Power factor Up to 1, without power derating
Inverter: 125% for 10 min, 150% for 30 s, >150% for 0.1 s;
Overload capacity
bypass: 150% continuous, 1000% for 1 cycle
Efficiency (AC/AC)* Up to 99%
Classification as per
VFI-SS-111
IEC/EN 62040-3
Connectivity and function extensions
Front panel 10” colour touch screen display, 1024x600 pixels
Included: serial RS232 and USB, backfeed protection monitoring contact,
input terminal block (remote emergency power off, battery circuit breaker aux. cont.,
external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont.,
Remote communication external output circuit breaker aux. cont., remote transfer to bypass mode).
Optional: SNMP adapter (Ethernet), Web interface (Ethernet), ModBus-TCP/IP (Ethernet), ModBus-RTU (RS485),
from ModBus-RTU to PROFIBUS DP adapter; SPDT contact relay board;
remote system monitoring panel; UPS managing and server shutdown software
Isolation transformer; transformers/autotransformers for voltage adjustment;
external maintenance bypass; custom battery cabinets; wall-mounted battery fuse switch box;
Optional function extension
battery thermal probe; parallel kit, load-sync for single UPS and load-sync box (2 UPS systems); top cable entry;
tripping coil for bypass disconnector; other options on request
System
Protection degree IP 20
Colour RAL 9005
Installation layout Wall, back to back and side by side installation allowed
Accessibility Front access, bottom cable entry
Other features
Environmental
Operating temperature range 0°C to +40°C
Storage temperature range -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) <60
Standards and certifications
Quality assurance,
ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007
environment, health and safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environmental aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3
Protection degree IEC 60529
Marking CE
25
INGENIO MAX series options
Description When do I use it
LOAD A LOAD B
LOAD SYNC
To synchronize the output of two paralleled UPS systems
BOX Load-sync box for two sets of paralleled UPS for no-break load transfers by
downstream static transfer switches
LOAD A LOAD B
Top
To allow input and output cable entry from the
cable Top cable entry in extended cabinet
entry top of the unit
Battery fuse switch in wall-mounted box To disconnect and protect an external battery pack
Input terminal block for external manual bypass When there is an external maintenance bypass switch,
switch auxiliary contact for state monitoring
Input terminal block for external battery switch When there is an external battery switch,
auxiliary contact for state monitoring
Input terminal block for external When there is an external output breaker,
output circuit breaker for status monitoring
26
B9000FXS
Uninterruptible Power Supply
3ph from 60 to 300 kVA
Applications Highlights
• Small and medium data centers • On-line double conversion
• Networks and servers • Full IGBT technology
• Industrial control and process • Paralleling up to 1.8 MVA
automation
• Medical equipment
• Building automation
27
B9000FXS
Uninterruptible Power Supply
3ph from 60 to 300 kVA
28
B9000FXS technical data
Rating (kVA) 60 80 100 125 160 200 250 300
Nominal power (kW) 54 72 90 112.5 144 180 225 270
Dimensions WxDxH (mm) 815x825x1670 1200x860x1900
UPS weight (kg) 570 600 625 660 715 970 1090 1170
Battery configuration External, 300 to 312 cells, VRLA (other options)
Input
Connection type Hardwired 3w (rectifier), 4w (bypass)
400 Vac 3-phase (rectifier)
Nominal voltage
380/400/415 Vac 3-phase with neutral (bypass)
Voltage tolerance -20%, +15% (rectifier); ±10% (bypass)
Frequency and range 50/60 Hz, 45 to 65 Hz
Power factor 0.99
Current distortion (THDi) <3%
Output
Connection type Hardwired 4w
Nominal voltage 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Static: ±1%;
Voltage regulation
dynamic: IEC/EN 62040-3 Class 1
Power factor Up to 0.9, lagging or leading without power derating
Inverter: 125% for 10 min, 150% for 1 min, 199% for 10 s, 200% for 100 ms;
Overload capacity
bypass: 150% continuous, 1000% for 1 cycle
Efficiency (AC/AC)* Up to 98%
Classification as per
VFI-SS-111
IEC/EN 62040-3
Connectivity and function extensions
Front panel Graphic display, mimic LED panel and keyboard, local EPO
Included: serial RS232 and USB; input terminal block for: remote emergency
power off (REPO), battery circuit breaker aux. cont., external maintenance bypass
circuit breaker aux. cont., diesel mode aux. contact.
Remote communication Optional: SNMP adapter (Ethernet), Web interface (Ethernet), ModBus-TCP/IP
(Ethernet); ModBus-RTU (RS485); ModBus-RTU to PROFIBUS DP adapter;
SPDT contact relay board; remote system monitoring panel;
UPS managing and server shutdown software
Isolation transformer; transformers/autotransformers for voltage adjustment;
external maintenance bypass; custom battery cabinets; wall-mounted battery fuse
Optional function extensions
switch box; battery thermal probe; parallel kit, top cable entry;
load-sync for single UPS and load-sync box (2 UPS systems); backfeed protection; other options on request
System
Protection degree IP 20 (other options)
Colour RAL 7016 (other options)
Installation layout Wall, back to back and side by side installation allowed
Accessibility Front and top access, bottom cable entry
Other features
Environmental
Operating temperature range 0°C to +40°C
Storage temperature range -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1m (dBA) <62
Standards and certifications
Quality assurance,
environment, health and ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007
safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environmental aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3 (VFI-SS-111)
Protection degree IEC 60529
Marking CE
29
B9000FXS series options
Description When do I use it
LOAD A LOAD B
LOAD SYNC
To synchronize the output of two paralleled UPS systems
BOX Load-sync box for two sets of paralleled UPS for no-break load transfers by
downstream static transfer switches
LOAD A LOAD B
Top
To allow input and output cable entry from the
cable Top cable entry in extended cabinet
entry top of the unit
Battery fuse switch in wall-mounted box To disconnect and protect an external battery pack
Input terminal block for external manual bypass When there is an external maintenance bypass switch,
switch auxiliary contact for state monitoring
Input terminal block for external battery switch When there is an external battery switch,
auxiliary contact for state monitoring
30
B9600FXS
Uninterruptible Power Supply
3ph from 400 to 800 kVA
Applications Highlights
• Medium data centers • On-line double conversion
• Networks and servers • Full IGBT technology
• Industrial control and process • Paralleling up to 4.8 MVA
automation
• Medical equipment
• Building automation
31
B9600FXS
Uninterruptible Power Supply
3ph from 400-800 kVA
32
B9600FXS technical data
Rating (kVA) 400 500 600 800
Nominal power (kW) 360 450 540 720
Dimensions WxDxH (mm) 1990x990x1920 2440x990x2020 2440x990x2020 3640x990x1920
UPS weight (kg) 1820 2220 2400 3600
Battery configuration External, 300 to 312 cells, VRLA (other options)
Input
Connection type Hardwired 3w (rectifier), 4w (bypass)
400 Vac 3-phase (rectifier)
Nominal voltage
380/400/415 Vac 3-phase with neutral (bypass)
Voltage tolerance -20%, +15% (rectifier); ±10% (bypass)
Frequency and range 50/60 Hz, 45 to 65 Hz
Power factor 0.99
Current distortion (THDi) <3%
Output
Connection type Hardwired 4w
Nominal voltage 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Static: ±1%;
Voltage regulation
dynamic: IEC/EN 62040-3 Class 1
Power factor Up to 0.9, lagging or leading without power derating
Inverter: 125% for 10 min, 150% for 1 min, 199% for 10 s, 200% for 100 ms;
Overload capacity
bypass: 150% continuous, 1000% for 1 cycle
Efficiency (AC/AC)* Up to 98%
Classification as per
VFI-SS-111
IEC/EN 62040-3
Connectivity and function extensions
Front panel Graphic display, mimic LED panel and keyboard, local EPO
Included: serial RS232 and USB; input terminal block for: remote emergency
power off (REPO), battery circuit breaker aux. cont., external maintenance bypass
circuit breaker aux. cont., diesel mode aux. contact.
Remote communication Optional: SNMP adapter (Ethernet), Web interface (Ethernet), ModBus-TCP/IP
(Ethernet); ModBus-RTU (RS485); ModBus-RTU to PROFIBUS DP adapter;
SPDT contact relay board; remote system monitoring panel;
UPS managing and server shutdown software
Isolation transformer; transformers/autotransformers for voltage adjustment;
maintenance bypass switch in extended cabinet or wall-mounted box; custom battery cabinets;
Optional function extensions
wall-mounted battery fuse switch box; battery thermal probe; parallel kit; top cable entry;
load-sync for single UPS and load-sync box (2 UPS systems); other options on request
System
Protection degree IP 20 (other options)
Colour RAL 7016 (other options)
Installation layout Wall, back to back and side by side installation allowed
Accessibility Front and top access, bottom cable entry
Other features
Environmental
Operating temperature range 0°C to +40°C
Storage temperature range -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1m (dBA) <62
Standards and certifications
Quality assurance,
environment, health and ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007
safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environmental aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3
Protection degree IEC 60529
Marking CE
33
B9600FXS series options
Description When do I use it
LOAD A LOAD B
LOAD SYNC
To synchronize the output of two paralleled UPS systems
BOX Load-sync box for two sets of paralleled UPS for no-break load transfers by
downstream static transfer switches
LOAD A LOAD B
Top To allow input and output cable entry from the top of the unit.
Top cable entry.
cable B9600FXS series feature optional maintenance
entry Maintenance bypass
bypass for cost reduction when this is externally provided
Battery fuse switch in wall-mounted box To disconnect and protect an external battery pack
Input terminal block for external manual bypass When there is an external maintenance bypass switch,
switch auxiliary contact for state monitoring
Input terminal block for external battery switch When there is an external battery switch,
auxiliary contact for state monitoring
34
UPSAVER
Uninterruptible Power Supply
3ph from 400 kW to 1.6 MW
Applications Highlights
• Large data centers • Modular three phase
• Paralleling up to 12.8 MVA
• 4 modes of operation
• Low TCO
35
UPSAVER
Uninterruptible Power Supply
3ph from
400 kW to 1.6 MW
Features and benefits Main options
● Patented Green Conversion providing ● Centralized static bypass.
high efficiency and battery care
● Modular battery.
technology for continuous savings on
operating and maintenance expenditure. ● Transformers/autotransformers for
*conditions apply
36
UPSAVER technical data
Rating (kVA) 400 600 800 1000 1200 1400 1600
N nominal power (kW) 400 600 800 1000 1200 1400 1600
N+1 nominal power (kW) 200 400 600 800 1000 1200 1400
UPS dimensions WxDxH (mm)* 2350x970x2100 2950x970x2100 3900x970x2100 4500x970x2100 5100x970x2100 6800x970x2100 7400x970x2100
UPS weight (kg)* 1660 2260 2920 3590 4190 4960 5560
Battery configuration External 360 to 372 cells, VRLA (other options)
Input
Connection type Hardwired 4w (rectifier), 4w (bypass)
400 Vac 3-phase with neutral (rectifier),
Nominal voltage
380/400/415 Vac 3-phase with neutral (bypass)
Voltage tolerance -20%, +15% (rectifier); ±10% (bypass)
Frequency and range 50/60 Hz, 45 to 65 Hz
Power factor 0.99
Current distortion (THDi) <3%
Output
Connection type Hardwired 4w
Nominal voltage 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Static: ±1%;
Voltage regulation (VFI)
dynamic: IEC/EN 62040-3 Class 1
Power factor Any power factor (leading or lagging) up to 1, without power derating
Inverter: 125% for 10 min, 150% for 1 min;
Overload capability
bypass: 150% continuous, 1000% for 1 cycle
AC/AC efficiency** Up to 99.5%
Classification as per IEC/EN 62040-3 VFI-SS-111
Connectivity and function extensions
Front panel 10” colour touch screen display, 1024x600 pixels
Included: serial RS232 and USB; input terminal block (remote emergency power off, battery circuit breaker aux. cont.,
external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont.,
Remote communication
external output circuit breaker aux. cont., remote transfer to bypass mode); SPDT contact relay board; ModBus-RTU (RS485);
Optional: ModBus-TCP/IP (Ethernet); ModBus-RTU to PROFIBUS DP adapter
Isolation transformer; custom battery cabinets; wall-mounted battery fuse switch box; battery thermal probe; parallel kit;
Optional function extensions
load-sync for single UPS and load-sync box (2 UPS systems); other options on request
System
Protection degree IP 20
Colour RAL 9005
Installation layout Wall, back to back and side by side installation allowed
Accessibility Front and top access, bottom and top cable entry
Parallel configuration Up to 8 UPS, for a total of 12.8 MW
* referred to distributed battery, distributed static switch, bottom cable entry. For other configurations contact our sales team ** according to IEC/EN 62040-3
Other features
Environmental
Operating temperature 0°C to +40°C
Storage temperature -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1m (dBA) <50 (UHE)
Standards and certifications
Quality assurance, environment,
ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007
health and safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environmental aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3
Protection degree IEC 60529
Marking CE
37
UPSAVER series options
Description When do I use it
LOAD A LOAD B
LOAD SYNC
To synchronize the output of two paralleled UPS systems
BOX Load-sync box for two sets of paralleled UPS for no-break load transfers by
downstream static transfer switches
LOAD A LOAD B
Backfeed protection bypass contactor To be fully protected against backfeed energy upon static
(distributed static bypass version) bypass failure
Included
Included
Input terminal block for external manual bypass When there is an external maintenance bypass switch,
switch auxiliary contact for state monitoring
Input terminal block for external battery switch When there is an external battery switch,
auxiliary contact for state monitoring
Input terminal block for external When there is an external output breaker,
output circuit breaker for status monitoring
38
ECS
Emergency Central Systems
1ph - 3ph from 10 to 160 kVA
Applications Highlights
• Emergency and safety systems • Compliant with EN 50171
• Emergency lighting • On-line double conversion
• Fire fighting • Paralleling up to 960 kVA
• Safety equipment
39
ECS
Emergency Central Systems
1ph - 3ph from 10 to 160 kVA
40
E8031 ECS - E8033 ECS technical data
Rating (kVA) 10 15 20 30 40 50
Nominal power (kW) 9 13.5 18 27 36 45
Nominal power as per EN 50171 (kW) 7.5 11.3 15 22.5 30 37.5
UPS dimensions WxDxH (mm) 450x670x1200
UPS weight (kg) 100 110 110 140 140 170
Battery configuration External, 360 to 372 cells, VRLA (other options)
Input
3/1-phase units: hardwired 4w (rectifier), 3/3 phase units: hardwired 4w
2w (bypass) (separate bypass input available on request)
Connection type
3/3-phase units: hardwired 4w (separate bypass input
available on request)
400 Vac 3-phase with neutral (rectifier) 400 Vac 3-phase with neutral (rectifier)
Nominal voltage
220/230/240 Vac (3/1-phase bypass)
Voltage tolerance -20%, +15% (rectifier); ±10% (bypass)
Frequency and range 50/60 Hz, 45 to 65 Hz
Power factor 0.99
Current distortion (THDi) <4%
Output
3/1-phase units: hardwired 2w 3/3 phase units: hardwired 4w
Connection type
3/3-phase units: hardwired 4w
3/1-phase units: 220/230/240 Vac 1-phase 380/400/415 Vac 3-phase with neutral
Nominal voltage
3/3-phase units: 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Voltage regulation Static: ±1%; dynamic: IEC/EN 62040-3 Class 1
Power factor Up to 0.9, lagging or leading without power derating
120% continuous;
Overload capacity* 150% for 10 min;
180% for 60 s
Efficiency (AC/AC)** Up to 98%
Classification as per IEC/EN 62040-3 VFI-SS-111
Connectivity and function extensions
Front panel
Graphic display, mimic LED panel and keyboard, local EPO
Included: serial RS232 and USB; terminal block for battery breaker auxiliary contact.
Optional: input terminal block (remote emergency power off, battery circuit breaker aux. cont.,
Remote communication external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont.); SNMP adapter (Ethernet),
Web interface (Ethernet), ModBus-TCP/IP (Ethernet), ModBus-RTU (RS485), from ModBus-RTU to PROFIBUS DP adapter;
SPDT contact relay board; remote system monitoring panel; UPS managing and server shutdown software
Isolation transformer; transformers/autotransformers for voltage adjustment;
external maintenance bypass; custom battery cabinets; wall-mounted battery fuse switch box; battery thermal probe;
Optional function extensions
load-sync for single UPS; AO+EO mode kit; separate input for rectifier and bypass line
(for 3-phase output models); parallel kit; backfeed protection (standard with 10, 15 and 20 kVA ratings); other options on request
System
Protection degree IP 20
Colour RAL 7016
Installation layout 10 cm wall-gap, side by side installation allowed
Accessibility Front and top access, bottom cable entry
*as per EN 50171 **as per IEC/EN 62040-3
Other features
Environmental
Operating temperature range 0°C to +40°C
Storage temperature range -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) <52
Standards and certifications
CPSS EN 50171
Quality assurance,
ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007
environment, health and safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environmental aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3
Protection degree IEC 60529
Marking CE
41
INGENIO ECS technical data
Rating (kVA) 60 80 100 125 160
Nominal power (kW) 60 80 100 125 160
Nominal power as per EN 50171 (kW) 50 67 83 104 133
UPS dimensions WxDxH (mm) 560x940x1800
UPS weight (kg) 250 300 320 360 380
Battery configuration External 360 to 372 cells, VRLA (other options)
Input
Connection type Hardwired 4w (rectifier), 4w (bypass)
400 Vac 3-phase with neutral (rectifier)
Nominal voltage
380/400/415 Vac 3-phase with neutral (bypass)
Voltage tolerance -20%, +15% (rectifier); ±10% (bypass)
Frequency and range 50/60 Hz, 45 to 65 Hz
Power factor >0.99
Current distortion (THDi) <3%
Output
Connection type Hardwired 4w
Nominal voltage 380/400/415 Vac 3-phase with neutral
Frequency 50/60 Hz
Static: ±1%;
Voltage regulation
dynamic: IEC/EN 62040-3 Class 1
Power factor Up to 1, without power derating
120% continuous;
Overload capacity* 150% for 10 min;
180% for 60 s
Efficiency (AC/AC)** Up to 99%
Classification as per
VFI-SS-111
IEC/EN 62040-3
Connectivity and function extensions
Front panel Graphic display, mimic LED panel and keyboard, local EPO
Included: serial RS232 and USB; backfeed protection monitoring contact,
input terminal block (remote emergency power off, battery circuit breaker aux. cont.,
external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont.).
Remote communication
Optional: SNMP adapter (Ethernet), Web interface (Ethernet), ModBus-TCP/IP (Ethernet), ModBus-RTU (RS485),
from ModBus-RTU to PROFIBUS DP adapter; SPDT contact relay board;
remote system monitoring panel; UPS managing and server shutdown software
Isolation transformer; transformers/autotransformers for voltage adjustment;
external maintenance bypass; custom battery cabinets; wall-mounted battery fuse switch box;
Optional function extension
battery thermal probe; parallel kit, load-sync for single UPS and load-sync box (2 UPS systems);
AO+EO mode kit; backfeed protection; other options on request
System
Protection degree IP 20
Colour RAL 9005
Installation layout Wall and side by side installation allowed
Accessibility Front access, bottom cable entry
Other features
Environmental
Operating temperature range 0°C to +40°C
Storage temperature range -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) <60
Standards and certifications
CPSS EN 50171
Quality assurance,
ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007
environment, health and safety
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2
Environmental aspects IEC/EN 62040-4
Test and performance IEC/EN 62040-3
Protection degree IEC 60529
Marking CE
42
STS
Static Transfer Switches
From 16 to 3000 A
Applications Highlights
• Networks and servers • Short circuit protection
• Data centers • No break seamless transfers
• Industrial control and process • High availability
automation
43
STS 16
STS 32
Static Transfer Switches
1ph from 16 to 32 A
Features and benefits ● LCD/LED display, providing user friendly
interface.
● Dual redundant power supplies to ● Comprehensive set of communication
control boards, for increased availability. options for total remote monitoring of
● Redundant cooling and fan failure equipment operation.
monitoring, for reliable operation.
● Real-time SCR fault sensing, preventing
fault propagation. Main options
● High overload capability, for robust
● 100/110/115/120/127 Vac nominal voltage
electrical design.
and NEMA sockets.
● ITS maintenance switch, for hot swap
● ITS maintenance switch.
maintainability.
● Compact 19” rack system design, for ● RS485 ModBus interface.
easy integration. ● SNMP interface.
Bypass 1
Source 1 Input 1
Output
Loads
Source 2 Input 2
44
STS 16 - STS 32 technical data
Model STS 16 STS 32
Rating (A) 16 32
Dimensions WxDxH (mm) 440x275x88
Weight (kg) 8 9
Input
Connection type Hardwired 5w
Nominal voltage 200/208/220/230/240 Vac 1-phase
Voltage tolerance ± 5% (up to ±20%)
Absolute maximum voltage range 150 Vac to 300 Vac
Frequency and range 50/60 Hz, ± 5% (up to ±20%)
Source harmonic voltage content Unlimited
Transfer phase angle 5° to 20°
Output
Connection type 8 IEC-C 13, hardwired 3w Hardwired 3w
Nominal voltage 200/208/220/230/240 Vac 1-phase
Frequency 50/60 Hz
Transfer time 2 to 6 ms
Transfer mode Break before make, transfer inhibit on fault
Load power factor 1 to 0.3
Maximum crest factor 3:1
THD current feedack from load Unlimited
Overload capacity 125% for 10 min, 150% for 1 min, 700% for 0.6 s
Efficiency (AC/AC) 99%
Connectivity and function extensions
Front panel Graphical LCD display
Included: RS-232 ModBus, USB, voltage free relay contacts;
Remote communication
Optional: one slot for SNMP adapter or RS-485 ModBus adapter
System
Protection degree IP 20
Colour RAL 9005
Installation layout Rack mounted
Accessibility Front and rear
Other features
Environmental
Operating temperature range -5°C to +40°C
Storage temperature range -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1 m (dBA) <60
Standards and Certifications
Quality assurance,
ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007
environment, health and safety
Safety IEC 60950-1
EMC EN 55022, EN 55024
Transfer voltage limit IEEE Standard 446
Protection degree IEC 60529
Performance IEC/EN 62310-3
Marking CE
45
STS 300
Static Transfer Switches
3ph from 100 to 3000 A
Bypass 1
Source 1 Input 1
Source 2 Input 2
Bypass 2
46
STS 300 technical data
Rating (A)* 100 250 400 630 800 1000 1250
Dimensions WxDxH (mm)** 820x835x1475
1220x860x1900 2000x1000x2100
Weight (kg)** 265 290 305 615 660 1000 1450
Input
Connection type Hardwired 4w
Nominal voltage 208/380/400/415/440/480 Vac 3-phase with neutral
Voltage tolerance ±10% (up to ±20% on request)
Frequency and range 50/60 Hz, ±2 Hz (up to ±4 Hz on request)
Source harmonic voltage
Unlimited (if THD>20% transfer time ≤10ms)
content
Transfer phase angle 5° to 30°
Output
Connection type Hardwired 4w
Nominal voltage 208/380/400/415/440/480 Vac 3-phase with neutral
Frequency 50/60 Hz
Transfer time ≤4 ms
Transfer mode Break before make, transfer inhibit on fault
Load power factor 1 to 0.3
Maximum crest factor 3:1
THD current fedback
Unlimited
from load
Overload capacity 125% for 30 min, 150% for 10 min, 200% for 30 s, 2000% for 1 cycle, 4000% for ½ cycle
Efficiency (AC/AC) >99%
Connectivity and function extensions
Front panel Graphical LCD display, mimic LED panel and keyboard
Included: dry contact relay card, RS232 and RS485 serial ports,
Remote communication ModBus-RTU protocol.
Optional: additional dry contact relay card
4-pole configuration; plug-in circuit breakers;
operation without neutral;
Optional function extensions
panel builder execution;
output distribution panels; isolation transformer
System
Protection degree IP 20 (other options)
Colour RAL 9005 (other options)
Installation layout Wall, back to back and side by side installation allowed
Accessibility Front access, bottom and top cable entry
*rating up to 3000 A on request **3-pole version
Other
features
Environmental
Operating temperature range 0°C to +40°C
Storage temperature range -10°C to +70°C
Altitude (AMSL) < 1000 m without power reduction, > 1000 m with reduction of 0.5% per 100 m
Audible noise at 1m (dBA) <62
Standards and certifications
Quality assurance,
environment, health ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007
and safety
Safety IEC/EN 62310-1
EMC IEC/EN 62310-2
Breakers IEC/EN 60947-3
Transfer voltage limits IEEE Standard 446
Protection degree IEC 60529
Performance IEC/EN 62310-3
Marking CE
47
GUARDIAN
NET
Remote Diagnostics
and Preventive
Monitoring Benefits Features
Extending Uptime Web Proactive Maintenance
Together with a Borri Maintenance Our Service specialists monitor your
Contract, Guardian Net allows our equipment from the Borri Service
Service specialists to take care of your Center, analyzing data and trends, to
system by monitoring its parameters proactively recommend actions for
and quickly reacting to anomalies. ensuring equipment always performs
at its best.
Increasing Business Continuity
Guardian Net improves Business Guardian Net provides you with Warning and alarm
Continuity by remote diagnostics and continuous monitoring of your system, notification
preventive monitoring of your UPS giving you comprehensive operational Guardian Net continuously monitors
system and peripherals by preventing awareness and providing technical the system and should any critical
unpredictable anomalies to become recommendations and reports by parameters exceed the preset
failures. Borri Service Center for improving the tolerance, it generates a warning or
Early detection of any deviations of quality and reliability of your system. alarm notification to you and the Borri
critical parameter and prompt reaction
Service Center.
in case of alarms result in extended Reducing Total Cost of Our Service specialists will investigate
uptime and enhanced operational Ownership the data, find the cause and take
efficiency. Real time monitoring and Guardian Net is an on-site virtual actions based on the customer’s
periodic reports on the health of Service specialist 24/7, monitoring maintenance contract.
equipment provide complete peace of all relevant parameters, maximizing This ensures that in case Service
mind, delivering unparalleled support system performance, reducing on-site engineers are dispatched on-site, they
experience. maintenance and minimizing your total arrive prepared for first time resolution,
cost of ownership by extending the life reducing downtime and increasing
of your critical equipment. system availability.
Status Reports
The unit parameters are collected by
our Service Center and presented in
periodic status reports.
You will receive a comprehensive
analysis of your equipment and its
INFO operational performance, as well as
demonstration that it is under
continuous remote monitoring.
WARNING
OK
48
Guardian Net for critical systems
49
Borri Service
Borri Service Battery tests
Customer’s expectation defines Borri’s Batteries have a limited time life and
priority from the early analysis of the their proper maintenance is of high
project requirements to a worldwide importance to guarantee efficiency to
commissioning and service. the UPS and avoid potential failures.
Many thousands of systems have been Borri delivers high quality and
successfully installed and maintained performing batteries to assure smooth
globally, with continuous support from operations.
a highly trained team of expert,
certified technicians and engineers. Repair & spare parts
From the professional set-up of Borri’s All spare parts supplied by Borri are
training center or on site, the training original, tested and guaranteed to be
and service team stand ready to fully compliant with Borri solutions.
provide support and contribute to
tailored training at Borri or on site.
You can be assured of Borri support to
Training
the highest standards no matter where Borri offers distributors and customers
in the world you are. a service training structured in 3 levels.
Courses can be held in Borri training
Planning, installation, centers or on-site.
commissioning
Remote monitoring
Borri assist you in every single step of
your project. Guardian Net remote monitoring
Our R&D team can analyze and system allows you to detect any
develop solutions to a wide range of deviation from optimum operation and
edge system requirements. trigger proper and immediate
response, so that anomalies don’t
evolve into issues.
Maintenance
Preventive maintenance guarantees
uninterrupted operations and
optimized system efficiency.
Analytical tests
Borri undertakes a series of analytical
tests in order to guarantee higher
efficiency and continuity to your
system operation.
Applications
● Oil & Gas
● Power generation and water treatment
● Power transmission & distribution
● Transportation
Borri S.p.A
Via 8 Marzo, 2
52011 Bibbiena (AR)
Italy
Tel. +39 0575 5351
Fax +39 0575 561811
info@borri.it
Asia Pacific
Borri Asia Pacific
Engineering Sdn. Bhd.
No: 5, Jalan PJU 3/38
Sunway Damansara Technology Park
47810, Petaling Jaya, Selangor
Malaysia
OMG60177revE - 01-2018 - Due to our policy of continuous development, data in this document is subject to change without notice and becomes contractual only after written confirmation
Tel. +60 3 7885 0999
Fax +60 3 7731 3666
sales@borri-asia.com
Canada
Borri Power Systems
North America Inc.
205 - 3689 E 1st Ave.
Vancouver, BC V5M 1C2
Canada
Tel. +1 604 439 3054
Fax +1 604 439 3053
info@borripower.com
Germany
Borri Power Germany GmbH
Von-Stauffenberg-Strasse 10
63179 Obertshausen
Germany
Tel. +49 6104 8023 942
Fax +49 6104 4098 554
info@borri.de
India
Borri Power India Pvt. Ltd.
Plot No. 69, Ground Floor
Nagarjuna Hills, Panjagutta
Hyderabad, 500 082
India
Tel. +91 40 2335 4095
info@mea.borripower.com
USA
Borri Power (US) Inc.
9000 Clay Road, Suit 108
Houston, Texas, 77080
USA
Tel. +1 346 212 2686
Fax +1 346 980 8875
info@borripower.com www.borri.it