Rodurflex Catalog
Rodurflex Catalog
I
RODURFLEX® SYNONYMOUS WITH QUALITY AND EXPERIENCE
I
THE RODURFLEX® SYSTEM
7 1 2 7 5 8 6 6 3 4 3
7’
1970
5 2’ 5’ 4’
5’
Hydrolysis
1975
6 6’ Resistant
Epoxy
HTV - Thickness
Silicone 3 mm
6’
8 1980 1’ 7’
8’ Meta-
stable
ECR -
SIR
Glass
4
1985 Forged
4’ 8’ 6’ Compression
Type Steel
3’ 3’
1990
3 3’
1995
1967
TODAY
RODURFLEX®
insulators have
been installed
world-wide in more
than 50 countries
at all voltage levels
up to 1100KV.
1
MECHANICAL RATING
SML=25,000 lbs. 111 kN SUSPENSION CLASS INSULATOR
RTL=12,500 lbs. 56kN
TYPICAL “X” ANSI CATALOG LEAKAGE DRY ARC ELECTRICAL FLASHOVER NET
LINE SECTION CLASS NUMBER WEIGHT
VOLTAGE LENGTH (KV)
INCHES INCHES Lbs.
(kV) (mm) INCHES mm (mm) DRY WET POS NEG (kg)
32 7.7
S25YB-03K1766 74 1880 (813) 315 260 520 535 (3.5)
69 41
(1041) 32
S25YB-00K8041 86 2184 315 260 520 535 8.6
(813) (3.9)
38 8.8
S25YB-03K1767 87 2210 (980) 380 315 630 650 (4.0)
69 47 60-1
(1194) 38
S25YB-03K1768 108 2743 380 315 630 650 10.6
(985) (4.8)
45 9.3
S25YB-01K9325 106 2692 (1155) 450 385 735 750 (4.2)
115 54
(1380) 45
S25YB-03K1773 120 3048 450 385 735 750 10.1
(1160) (4.6)
51 9.9
60 60-2 S25YB-01K9326 117 2972 (1310) 515 435 840 860 (4.5)
138 (1535)
60-3 S25YB-02K0866 3632 52 515 435 840 860 12.6
143 (1325) (5.7)
2
MECHANICAL RATING
SML=25,000 lbs 111 kN SUSPENSION CLASS INSULATOR
RTL=12,500 lbs. 56kN
TYPICAL “X” ANSI CATALOG LEAKAGE DRY ARC ELECTRICAL FLASHOVER NET
LINE SECTION CLASS NUMBER WEIGHT
VOLTAGE LENGTH (KV)
INCHES INCHES Lbs.
(KV) (mm) INCHES mm (mm) DRY WET POS NEG (kg)
81 670 1280 1300 14.3
S25YB-03K1781 198 5029 (2060) 810 (6.5)
230 90
(2286) 81
S25YB-03K1782 234 5944 810 670 1280 1300 17.6
(2075) (8.0)
5639 95 15.4
S25YB-03K1785 222 (2420) 950 770 1510 1600 (7.0)
230 104 60-10
(2642) 95 18.1
S25YB-03K1786 265 6731 (2420)
950 770 1510 1600 (8.2)
NOTES:
1. All section lengths are based on Y-Ball end fittings. See table below for length adjustments for other end fitting combinations.
2. Electrical values are per ANSI standards and are without corona ring(s).
3. All dimensions are within allowable ANSI tolerances.
4. Other leakage options and section lengths are available. Contact LAPP Insulator Company for special designs.
5. Dimensions, tolerances and testings per ANSI C29.11 and C29.12.
TOWER LINE
FITTING FITTING LENGTH CHANGE
Inches mm
EYE BALL +0.79 +20
EYE EYE +2.76 +70
SOCKET BALL -0.79 -20
CLEVIS BALL -0.59 -15
Y-CLEVIS EYE +1.97 +50
CLEVIS EYE +1.38 +35
3
MECHANICAL RATING
SML=30,000 lbs. 133 kN SUSPENSION CLASS INSULATOR
RTL=15,000 lbs. 67kN
NOTES:
1. All section lengths are based on Eye-Ball end fittings. See table below for length adjustments for other fitting combinations.
2. Electrical values are per ANSI standards and are without corona ring(s).
3. All dimensions are within allowable ANSI tolerances.
4. Other leakage options and section lengths are available. Contact LAPP Insulator Company for special designs.
5. Dimensions, tolerances and testings per ANSI C29.11 and C29.12.
4
MECHANICAL RATING
SML=30,000 lbs. 133 kN SUSPENSION CLASS INSULATOR
RTL=15,000 lbs. 67kN
TYPICAL “X” ANSI CATALOG LEAKAGE Dry ARC ELECTRICAL FLASHOVER NET
LINE SECTION CLASS NUMBER WEIGHT
VOLTAGE LENGTH (KV)
INCHES INCHES Lbs.
(KV) (mm) INCHES mm (mm) DRY WET POS NEG (kg)
73 31 250 14.1
45 S50EB-03K1801 1855 (795) 305 505 520 (6.4)
69 (1143)
S50EB-03K1802 87 2210 31 305 250 505 520 15.2
(805) (6.9)
NOTES:
1. All section lengths are based on Eye-Ball end fittings. See table below for length adjustments for other fitting combinations.
2. Electrical values are per ANSI standards and are without corona ring(s).
3. All dimensions are within allowable ANSI tolerances.
4. Other leakage options and section lengths are available. Contact LAPP Insulator Company for special designs.
5. Dimensions, tolerances and testings per ANSI C29.11 and C29.12.
6
MECHANICAL RATING
SML=50,000 lbs. 222 kN SUSPENSION CLASS INSULATOR
RTL=25,000 lbs. 111 kN
TYPICAL “X” ANSI CATALOG LEAKAGE DRY ARC ELECTRICAL FLASHOVER NET
LINE SECTION CLASS NUMBER WEIGHT
VOLTAGE LENGTH (KV)
INCHES INCHES Lbs.
(kV) (mm) INCHES mm (mm) DRY WET POS NEG (kg)
6528 109 28.0
S50EB-03K1821 257 (2775) >950 >950 1730 1780 (12.7)
123 70-5
345 (3124) 109 31.7
S50EB-03K1822 309 7849 (2780) >950 >950 1730 1780 (14.4)
139 33.5
S50EB-03K1827 330 8382 (3535) >950 >950 >2000 >2000 (15.2)
500 153 70-9
(3886) S50EB-03K1828 516 13106 139 >950 >950 >2000 >2000 47.6
(3545) (21.6)
162 33.3
S50EB-01K9360 330 8382 (4090) >950 >950 >2000 >2000 (15.1)
500 175 70-10
(4445) S50EB-02K0862 521 13106 162 >950 >950 >2000 >2000 48.9
(4110) (22.2)
NOTES:
1. All section lengths are based on Eye-Ball end fittings. See table below for length adjustments for other fitting combinations.
2. Electrical values are per ANSI standards and are without corona ring(s).
3. All dimensions are within allowable ANSI tolerances.
4. Other leakage options and section lengths are available. Contact LAPP Insulator Company for special designs.
5. Dimensions, tolerances and test per ANSI C29.11 and C29.12.
7
MECHANICAL RATING
SML=100,000 lbs. 450 kN SUSPENSION CLASS INSULATOR
RTL=50,000 lbs. 225kN
500 165 S100EE-03K2037 371 9440 145 >950 >950 >2000 >2000 65.5
(3690) (29.8)
NOTES:
1. Electrical values are per ANSI standards and are without corona ring(s).
2. All dimensions are within allowable ANSI tolerances.
3. Other leakage options and section lengths are available. Contact LAPP Insulator Company for special designs.
4. Dimensions, tolerances and test per ANSI C29.11 and C29.12.
8
MECHANICAL RATING
SML=25,000 lbs. 111 kN PORCELAIN STRING REPLACEMENT
RTL=12,500 lbs. 56 kN
NUMBER TYPICAL “X” CATALOG LEAKAGE DRY ARC ELECTRICAL FLASHOVER NET
OF SYSTEM SECTION NUMBER WEIGHT
BELLS VOLTAGE LENGTH (KV)
INCHES INCHES Lbs.
(KV) (mm) INCHES mm (mm) DRY WET POS NEG (kg)
28.7 S25SB-03K1831 55 1410 21 200 170 340 350 6.6
5 69 (730) (540) (3.0)
34.5 1735 27 215 435 450 7.3
6 69 (876) S25SB-03K1832 68 (685) 260 (3.3)
NOTES:
1. Catalog sequence S25SB is a socket/ball design with section length and leakage to match the corresponding
porcelain strings listed in column one.
2. Catalog sequence S25YB is a Y-Clevis/Ball design and increases the section length by approximately 3.25” to
compensate for elimination of the Y/Ball adapter commonly used to attach porcelain strings to the tower.
9
CORONA RING RECOMMENDATION
Rodurflex suspension insulators are designed to be corona and RIV free for system voltages of 138kV and below. For system
voltages above 138kV, the following corona rings are recommended. These corona rings will provide corona extinction at 115%
of nominal system voltage.
6.4” AND 7.8” RINGS 13.8” AND 17.7” RINGS 13.8” AND 17.7” RINGS
600 939 601 938 601 129
600 013 335 043 600 856
601 227 335 044
601 222 335 045
601 228
When corona rings are applied, the insulator characteristics provided in the product tables will be changed as listed below:
10
SUSPENSION INSULATORS END FITTING TYPES
S 25 YB XXXXXXX
S = Suspension Class 25 = 25K lbs.SML Y = Y-Clevis Fitting LAPP Sequence Number
30 = 30K lbs. SML B = Ball Fitting
50 = 50K lbs. SML S = Socket Fitting
100 = 100K lbs. SML E = Eye Fitting
C = Clevis Fitting
T = Tongue Fitting
11
SUSPENSION END FITTING DIMENSIONS
SML
Lbs. OVAL EYE Y-CLEVIS CLEVIS TONGUE SOCKET
(kN) BALL
A B C D A B A B C A B C
25,000
(111) 1.18 2.36 0.59 0.70 0.75 1.57 0.79 1.81 0.79 0.63 0.47 min 0.79 52-5
30,000
(133) 1.18 2.36 0.59 0.70 0.75 1.57 0.79 1.81 0.79 0.63 0.47 min 0.79 52-5
50,000 52-8
(222)
1.18 2.36 0.78 1.02 0.80 1.81 0.79 2.10 0.94 0.75 0.70 min 0.94 52-11
100,000 1.14 2.95 0.98 1.37
(450)
12
12º UPSWEEP ANGLE
TYPICAL “X” ANSI CATALOG LEAKAGE DRY ARC ELECTRICAL FLASHOVER RCL NET
LINE SECTION CLASS NUMBER WEIGHT
VOLTAGE LENGTH (kV)
INCHES INCHES Lbs. Lbs.
(kV) (mm) INCHES mm (mm) DRY WET POS NEG (kN) (kg)
24 2790 72
CLP2511-03K1957 75 1905 (605) 205 190 370 415 (12.4) (32.7)
69 35
37 CLP2511-03K1958 91 2315 26 245 215 405 445 2610 75
(660) (11.6) (34.1)
40 1780 81
CLP2511-03K1962 110 2800 (1020) 415 365 630 680 (7.9) (36.8)
138 52
52 250-47
CLP2511-03K1963 148 3760 40 415 1780 85
(1020) 365 630 680 (7.9) (38.6)
46 1575 84
CLP2511-03K1964 126 3195 (1175) 495 430 730 780 (7.0) (38.2)
161 58
58 250-54
46 1575 89
CLP2511-03K1965 164 4155 (1175) 495 430 730 780 (7.0) (40.4)
50 465 1460 88
62 CLP2511-03K1966 144 3655 (1275) 535 795 840 (6.5) (40)
161 62 250-60
CLP2511-03K1967 50 465 795 840 1460 92
182 4615 (1275) 535 (6.5) (41.8)
78 67 1050 1125 97
230 250-75 CLP2511-03K1970 183 4670 (1690) 705 600 1105 (5.0) (44.1)
NOTES:
1. Electrical values are per ANSI standards and are without a corona ring.
2. RCL is the maximum continuous cantilever load at which the insulator can be applied.
3. All dimensions are within allowable ANSI tolerances.
4. Other leakage options and section lengths are available. Contact LAPP Insulator Company for special designs.
5. Dimensions, tolerances and tests per ANSI C29.11 and C29.12.
13
12º UPSWEEP ANGLE
TYPICAL “X” ANSI CATALOG LEAKAGE DRY ARC ELECTRICAL FLASHOVER RCL NET
LINE SECTION CLASS NUMBER WEIGHT
VOLT- LENGTH (kV)
AGE Lbs.
INCHES INCHES Lbs.
(mm) INCHES mm (mm) DRY WET POS NEG (kN) (kg)
CLP2511-03K1972 195 73
4950 (1850) 770 655 1150 1210 1035 100
84 (4.6) (45.5)
230 250-75
84 73 104
CLP2511-03K1973 233 5910 (1850) 770 655 1150 1210 1035
(4.6) (47.3)
83 900 106
CLP2511-03K1976 224 5690 (2110) 850 720 1310 1370 (4.0) (48.2)
95 250-95
230
83 110
95 CLP2511-03K1977 252 6410 (2110) 850 720 1310 1370 900
(4.0) (50)
NOTES:
1. Electrical values are per ANSI standards and are without a corona ring.
2. RCL is the maximum continuous cantilever load at which the insulator can be applied.
3. All dimensions are within allowable ANSI tolerances.
4. Other leakage options and section lengths are available. Contact LAPP Insulator Company for special designs.
5. Dimensions, tolerances and tests per ANSI C29.11 and C29.12.
CLP 25 1 1 XXXXXXX
Composite Line Post 25 = 2.5” Rod Diameter 1 = Bendable Gain Base 1 = Horizontal Clamptop LAPP Sequence Number
2 = Bendable Flat Base 2 = Drop Tongue
3 = Vertical Clamptop
4 = 5” Bolt Circle
14
CLP END FITTING DIMENSIONS
HORIZONTAL AND VERTICAL FITTINGS
DIMENSIONS (Inches) A B C D E
15
STEEL GAIN STEEL FLAT
DIMENSIONS INCHES A B C D E F G
BENDABLE FLAT 10.0 14.0 12.0 6.1 0.87 0.87 x 1.50 8.07
16
LAPP INSULATOR COMPANY LLC
LAPP PUBLICATIONS
Bushing Division T&D Division
• LAPP Apparatus Bushings Catalog • Distribution Insulators Catalog
• LAPP Test Terminals Brochure • IEC Porcelain Suspension Insulators Catalog
• Repair and Diagnostics Brochure • Horizontal Vee Catalog
• Quick Link Bushing Brochure • Porcelain Suspension & Strut Insulators Catalog