Getinge Fd1800-Series Flusher-Disinfectors

The document discusses the Getinge FD1800-series flusher-disinfectors. It provides details on their cleaning and disinfection performance. Key features include automatic door functions, drying fans, adjustable disinfection settings, and process record tracking. The series offers flexibility through various models and materials. It also plays a central role in optimizing sluice rooms when used with the right holders, accessories, and complete room design from Getinge. Technical specifications are provided for dimensions, weight, water and power connections.

Uploaded by

Basheer Mohamed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
205 views8 pages

Getinge Fd1800-Series Flusher-Disinfectors

The document discusses the Getinge FD1800-series flusher-disinfectors. It provides details on their cleaning and disinfection performance. Key features include automatic door functions, drying fans, adjustable disinfection settings, and process record tracking. The series offers flexibility through various models and materials. It also plays a central role in optimizing sluice rooms when used with the right holders, accessories, and complete room design from Getinge. Technical specifications are provided for dimensions, weight, water and power connections.

Uploaded by

Basheer Mohamed
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

GETINGE FD1800-series

FLUSHER-DISINFECTORs
2 | Getinge FD1800
Getinge FD1800 | 3

PROVEN IN THE FIGHT AGAINST


CROSS-INFECTION

The excellent cleaning and disinfection performance of Getinge FD1800-series has made it
a well-established flusher-disinfector for hospitals and nursing homes, operating reliably and
efficiently in sluice rooms around the world.

As well as ensuring effcient and cost-effective Getinge FD1800-series has been upgraded in line
cleaning and disinfection of human waste with the Getinge policy to continuously improve
containers, Getinge FD1800-series has been its products and services. The result is a machine
designed to offer options and features, such as the that can play an even more important role in
sensor-activated door, that provide even greater your operations by offering new options and
support in effective routines to combat cross- opportunities. Getinge FD1800-series controls and
infection. tracks your processes, enhances your working
environment and efficiency, and takes disinfection
Getinge FD1800 is a range of front-loaded flusher- to a level that can tackle even the toughest
disinfectors that delivers excellent performance in microorganisms.
the emptying, cleaning, thermal disinfection and
drying of bedpans, urine bottles and commode
buckets. Steam delivered through the chamber’s
configuration of fixed and rotating nozzles
produces results that meet the stringent cleaning
and disinfection requirements of the European
flusher-disinfector standard, EN ISO 15883.
4 | Getinge FD1800

MORE CHOICE MEANS …

Getinge FD1800 offers a choice of models and materials, that can match all
sluice rooms needs. Process control and efficiency have been enhanced with the
latest features and options without compromising on cost effectiveness and the
environment.

Flexible design
The new standard casing is made of colorful polymeric
material, offering an attractive, modern design. Every
model is fitted with a stainless steel chamber. Getinge
FD1800 is also available as stainless steel model when
required.

Drying fan as standard


Receptacles are rapidly dried and cooled in the most
hygienic way using HEPA-filtered (H13) air. Dry and
cool receptacles are delivered at the end of the cycle,
improving staff safety and the working environment.

Automatic door function


To support hygienic non-contact routines, Getinge FD1800
has an option for an automatic door activated by an IR
sensor. To improve choice in automatic door operation, a
foot pedal option can also be chosen.

A0 setting & control


The A0 value can be set to 60 or 600 in order to fight even
the toughest microorganisms. The disinfection phase can
be controlled on temperature or on the chosen A0 value to
further shorten the cycle time
Getinge FD1800 | 5

...GREATER FLEXIBILITY

Remaining time sequence display


The display, showing the remaining time sequence in ten
second intervals, allows staff to check on cycle progress,
enabling them to plan their workflow more efficiently by
reducing time spent waiting for the process to end.

Process record
Many healthcare facilities are moving towards greater
transparency with detailed records of disinfection
operations. With PACS 350 control system, Getinge
FD1800 provides the option to record and track process
operations via a printer or USB device.

Environmental-friendly operation
Exceptionally low consumption of water, energy and
chemicals reduces overall impact on the environment and
keeps operational costs to its minimum. Furthermore, low
heat emissions and a low noise level contribute to a better
working environment.

Optional IPX4 classification


With increased infection control awareness in hospital
wards and departments all over the world, many patient
rooms require a flusher disinfector in the adjoining
bathroom. For safe wet room installations, IPX4
classification is recommended.

Pipe System Disinfection (PSD)


Rapid disinfection through all fixed and rotating nozzles
also delivers a unique benefit, as the entire pipe and
nozzle system is disinfected in every cycle, eliminating the
risk of contamination.
6 | Getinge FD1800

CREATING A COMPLETE SOLUTION

Getinge FD1800 plays a central role in an efficient sluice room, but is only one element in
effective infection control. Getinge can help you to create an optimized sluice room and establish
an overall infection control strategy.

After choosing flusher disinfector, the following three steps can be


seen as a guidance in creating a complete solution:

STEP 1: Choosing the right holder


The universal holder takes most commonly used receptacles. There
is also a wide range of holders available for other types of goods.
These holders can handle a variety of bedpans, as well as most
commode buckets and urine bottles. The optimal performance level
can only be reached by selecting the optimal holder from the
comprehensive standard range offered by Getinge.

Urine bottle and bedpan with lid


STEP 2: Adding accessories
Getinge also offers a number of valuable accessories, such as a
unique, anatomically designed bedpan with lid. Getinge’s chemicals,
an optimized rinse and deliming agent and a highly efficient
detergent, are designed to meet the most stringent process
demands.

STEP 3: Designing a complete sluice room


Getinge considers every aspect of the sluice room and provides a
wide range of support from training in good hygiene routines to
advice on room layout and equipment selection. Getinge also offers
a complete furniture concept for the sluice room, enabling to create
a hygienic and safe working environment for the customer. Three urine bottles

Getinge’s range of detergents has been devel-


oped, tested and validated on Getinge’s flusher-
disinfectors for human waste containers to meet
EN ISO 15883 standards for cleaning efficiency
of goods commonly found in sluice rooms and
to protect users and patients.

Getinge Clean flusher range


Getinge FD1800 | 7

TECHNICAL INFORMATION

Getinge FD1800-series is available in steel and polymeric under-counter and freestanding models

GETINGE FD1800-SERIES

Free-standing (FD1800, FD1810) Under-counter (FD1805)

Width 450 mm (17 /16”)


11
900 mm (35 7/16”)

Depth 580 mm (22 3/4”) 620 mm (24 1/4”)

Height 1320 mm (51 7/8”) 870 mm (34 3/16”) without worktop


900 mm (35 7/16”) with optional worktop

Weight 100 kg (220 lbs.) 120 kg (265 lbs.)

Free-standing and under-counter (FD1800, FD1805, FD1810)

Drain connection wall / floor Ø 110 mm (4 ¼”)


wall / floor Ø 90 mm (3 ½”)

Power consumption 0,16 kWh/cycle

Max. external temperature 40° C (100° F)

Noise level 53 dB (A) accordingly to EN ISO 3747:2000

Water connections – cold and hot water


Water 15 mm (½”)
Pressure 1-8 Bar (14-116 PSI)
Rate of flow >0,3 l/s

Water consumption Economy program 11 liters/cycle ±10 %


Normal program 18 liters/cycle ±10 %
Intensive program 25 liters/cycle ±10 %

Approvals MDD 93/42/EEC. Third party certificate for


EN ISO 15883-1 and 15883-3

Dimensions and specifications of Getinge FD1800 matching cabinets available on request.


2337 ENG Rev. E 2014.07 · Göteborgstryckeriet · We reserve the right to make technical and construction changes.
Getinge Infection Control is the world leading
provider of solutions for sterile processing in the
healthcare sector. We aim to ensure the highest
quality and safety at the lowest total cost. We offer
complete solutions for a seamless work-flow,
reducing the risk of contamination while helping
healthcare to increase efficiency.

Getinge Infection Control AB


P O Box 69
SE-305 05 Getinge
SWEDEN
Phone: +46 (0) 10 335 00 00
E-mail: info@getinge.com

GETINGE GROUP is a leading global provider of products and systems that


contribute to quality enhancement and cost efficiency within healthcare and life
sciences. We operate under the three brands of ArjoHuntleigh, GETINGE and
MAQUET. ArjoHuntleigh focuses on patient mobility and wound management
solutions. GETINGE provides solutions for infection control within healthcare and
contamination prevention within life sciences. MAQUET specializes in solutions,
getinge.com therapies and products for surgical interventions, interventional cardiology and
intensive care.

You might also like