0% found this document useful (0 votes)
48 views1 page

Compact Cylindrical Filters for Power Supplies

The document summarizes MB series cylindrical filters that are designed for compact mounting in switching power supplies and household appliances. It provides specifications for the filters, including maximum leakage current, hipot rating, operating frequency, rated voltage, and insertion loss data in decibels from 0.01 MHz to 100 MHz. It also includes an electrical schematic and details on the mechanical construction of the filters.

Uploaded by

321ruben
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
48 views1 page

Compact Cylindrical Filters for Power Supplies

The document summarizes MB series cylindrical filters that are designed for compact mounting in switching power supplies and household appliances. It provides specifications for the filters, including maximum leakage current, hipot rating, operating frequency, rated voltage, and insertion loss data in decibels from 0.01 MHz to 100 MHz. It also includes an electrical schematic and details on the mechanical construction of the filters.

Uploaded by

321ruben
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

SERIES HIGH PERFORMANCE CYLINDRICAL FILTERS

GENERAL PURPOSE ONE-STAGE FILTERS


INTRODUCTIONS SPECIFICATIONS
MB series is designed as a compact, easy-to-mount
1. Maximum leakage current each
cylindrical filter for switching power supplies, office
line-to-ground @115VAC 60Hz: 1.0mA
equipment (copy and facsimile machines) and household
@250VAC 50Hz: 2.0mA
appliances (washing machines and dryers).
2. Hipot rating (one minute)
line-to-ground: 2250VDC
COMPONENTS line-to-line: 1450VDC
3. Operating frequency: 50/60 Hz
PART No. L(mH) Cx(uF) Cy(pF) R(K ) Safety
4. Rated voltage: 115/250VAC
10MBFG5 0.5 0.47 10000 680
16MBFG5 1.0 0.47 10000 680
dB Insertion Loss(Typical) 10MBFG5
With optional inductance 1.0mH / Capacitance from 0.15uF to 0.68uF for Cx, 60
1000pF to 27000uF for Cy / Resistance up to 1.0M .
With optional Capacitance from 0.1uF to 1.0uF for Cx, 50
100pF to 27000uF for Cy / Resistance up to 2.2 M .
40
MINIMUM INSERTION LOSS IN dB
30 DIF MODE
COMMON MODE (L-G) IN 50 OHM SYSTEM COMMODE
CURRENT FREQUENCY-MHz 20
TYPE
RATING .15 .50 1.0 5.0 10 30
10
10MBFG5 10A 5 19 27 44 32 21
16MBFG5 16A 11 26 31 30 20 4 0
DIFFERENTIAL MODE (L-L) IN 50 OHM SYSTEM 0.01 0.1 1 10 100 Frequency(MHz)
10MBFG5 10A 1 12 20 19 20 22
16MBFG5 16A 11 24 12 14 17 28
dB Insertion Loss(Typical) 16MBFG5
ELECTRICAL SCHEMATIC 60

50

40

30 DIF MODE
COMMODE
20

10

0
0.01 0.1 1 10 100 Frequency(MHz)
+ 0.2
+ 0.2

8.2- 0
2.2- 0

With optional schematic for 16MBFG5.

MECHANICAL CONSTRUCTION
+0.2
10.2 - 0
0.472 0.012

0.472 0.012
12.0 0.3

12.0 0.3

RECOMMENED MOUNTING
mm
M8x1.25
0.453 0.012

0.453 0.012
L

L
11.5 0.3

11.5 0.3

L2 N4 L2 N4
U1 U3 U1 U3
FAST ON 6.3X0.8 FAST ON 6.3X0.8
1.512 0.019 1.512 0.019
38.4 0.5 38.4 0.5 L= 40mm.(1.575inch)
L= 40mm.(1.575inch) 50mm.(1.968inch)
SCREW TYPE 50mm.(1.968inch) SNAP TYPE

UNIT: INCH
5-12 mm