AIAG» cars
‘Special Process: Heat Treat System Assessment
The catayst for pook performance Version 3, Issued 10/2011
ABOUT AIAG
Purpose Statement
Founded in 1982, AIAG is a globally recognized organization where OEMs and suppliers unite to address
and resolve issues affecting the worldwide automotive supply chain. AIAG's goals are to reduce cost and
complexity through collaboration; improve product quality, health, safety and the environment; and
Optimize speed to market throughout the supply chain.
AIAG Organization
AIAG is made up of a board of directors, an executive director, executives on loan from member
companies, associate directors, a full-time staff, and volunteers serving on project teams. Directors,
department managers, and program managers plan, direct and coordinate the association's activities
Under the direction of the executive director.
AIAG Projects
Volunteer committees focus on business processes or supporting technologies and methodologies. They
conduct research and develop, publish, and provide training on standards, conventions, standard
business practices, white papers, and guidelines in the areas of automatic identification, CAD/CAM,
ED\electronic commerce, continuous quality improvement, health focus, materials and project
management, occupational health & safety, returnable containers and packaging systems,
transportation/customs and truck & heavy equipment,
‘AIAG PUBLICATIONS
‘An AIAG publication reflects @ consensus of those substantially concerned wit its scope and provisions. An
AIAG publication is intended as a guide to aid the manufacturer, the consumer, and the public. The existence of
{an AIAG publication does not in any respect preclude anyone from manufacturing, marketing, purchasing, or
using products, processes, or procedures not conforming to the publication.
CAUTIONARY NOTICE
AIAG publications are subject to periodic review and users are cautioned to obtain the latest editions.
MAINTENANCE PROCEDURE
Recognizing that this AIAG publication may not cover ail circumstances, AIAG has established a maintenance
‘Procedure. Please refer to the Maintenance Request Form at the back of this document to submit @ request.
Published by
Automotive industry Action Group
26200 Lahser Road, Suite 200
‘Southfield, Michigan 48033
Phone: (248) 358-2570 + Fax: (248) 358-3253
APPROVAL STATUS
The AIAG Quality Steering Committee and designated stakeholders approved this document for publication in
October 2011.
AIAG COPYRIGHT AND TRADEMARK NOTICE:
The Automotive industry Action Group copyrights the contents ofall published materials unless otherwise indicated. Copyright is not
Claimed as to any part of an original work prepared by a U.S. or state govemment officer or employee as part ofthe person’s official
duties. All rights are preserved by AIAG, and content may not be altered or disseminated, published, or transferred in part of such
Content. The information is not to be sold in part or whole to anyone within your organization or to another company. Copyright
intringement is violation of federal law subject to criminal and civil penalties. AIAG and the Automotive Industry Action Group are
registered service marks of the Automotive Industry Action Group.
©2011 Automotive Industry Action Group
ISBN 9 781 60534 2368cal-9
‘Special Process: Heat Treat System Assessment
Version 3, Issued 10/2011
AIAG
The catalyst for peak performaceAIAG care
Special Process: Heat Treat System Assessment
The catayst for paok performance Version 3, Issued 10/2011
FOREWORD
Automotive Industry Action Group (AIAG) committees are made up of volunteers from member
companies in the automotive industry. The work of preparing process audits is done by AIAG technical
committees.
The main task of technical committees is to prepare automotive standards and system requirements, Draft
documents adopted by the technical committees are circulated to the Steering Committee for review and
consensus approval. Publication of the documents requires approval by the Quality Steering Committee.
The Quality Steering Committee would like to acknowledge and thank the following individuals and their
companies who have contributed time and effort to the development of this document.
Philip Mikula (CQI-9 Chairperson) ~ TRW Automotive, Ine.
Dean Higdon ~ Acument Global Technologies North America
Pete Batche ~ Akebono Brake Corporation, North America
Stefan Bruder ~ Bodycote Warmebehandlung GmbH
Madhu Chatterjee ~ Bodycote Thermal Processing, North America
Rick Howell ~Chrysler Group LLC, North America
Darrell Rydzewski ~ Controls Service, Inc.
Virender Choudhri — Delphi Corporation
Stephen Toltesi ~ Eaton Corporation
Suranjeeta Dhar ~ Ford Motor Company
Peter Schiefer — Ford Motor Company, Germany
Medina Kaknjo — Ford Motor Company
Rick Metcalf — General Motors Company, North America
David Paluch — General Motors Company, North America
Werner Schwan ~ Robert Bosch GmbH Germany
Jeff Martin — ZF Friedrichshafen, AG
Luiz Tubino ~ LTC Desenvolvimento Empresarial LTDA, Brasil
Kevin Bauer ~ Keystone Powdered Metal Company
Delbert Clubine, Advance Heat Treat Corporationcal-9
‘Special Process: Heat Treat System Assessment
Version 3, Issued 10/2011
CHANGES TO CQI-9 3°° EDITION
The Special Process: Heat Treat System Assessment, 3” edition contains some new requirements,
changed requirements, and clarifications that the supply organization will need to consider in making its
self-assessment. This 3" edition is a collaborative work of OEM, Tier | suppliers, heat treat suppliers,
and calibration companies that service the heat treat industry. Below is a summary of the important
changes in this 3" edition.
1. Three new Process Tables have been added:
‘© Low Pressure Carburizing
© Sinter Hardening
Ton (Plasma) Nitriding
2. The format and layout of the Process Tables have been improved to facilitate the heat treat system
assessment.
3. References to AMS 2750D have been removed and replaced with AIAG CQI-9 specific
requirements.
4, Frequency for SAT and Instrument Calibration have been changed. The requirement in the 3°
Edition allows the heat treater to choose one of the two following options:
Option 1: Quarterly SAT (Probe Method A or B) or Monthly SAT (Comparative Method),
and Quarterly Control Instrument Calibration (single-point or multi-point
calibration).
Option 2: Quarterly SAT (Method A only) and Semi-Annual Control Instrument
Calibration (multi-point calibration; 1-point calibration not allowed with semi-
annual frequency).
5. The 3" Edition allows two options for the frequency for calibrating oxygen probe controllers
(used in carbon-bearing atmospheres):
© Quarterly (single-point calibration or multi-point calibration is allowed)
© Semi-annual (multi-point calibration method; single-point calibration is not allowed)
6. Frequency for checking the quench oil cooling curve was changed to semi-annual (2™ Edition
required quarterly frequency checks).
7. The temperatures given in °C and “F were harmonized. That is, the direct conversion from °C to
°F is not used but rather the common tolerances for °C and °F were used. For example, the TUS
tolerance for carburizing furnaces is + 15 °C (+ 25°F).
Questions 1.20, 3.20, and 3.21 were added to the CQI-9 Heat Treat System Assessment.
Question 1.11 was modified. This question addresses re-processing procedures.
10. Question 3.7 ~ The oxygen probe controller (carbon controller) shall control the carbon potential
+/- 0.05%.
11. Question 3.12 was modified. This question addresses the proper height of the workload on a
continuous belt furnace.AIAG 2» cai
Special Process: Heat Treat System Assessment
The catalyst pook performance Version 3, issued 1072011
TABLE OF CONTENTS
‘ABOUT AIAG.
0S
Special Process: Heat Treat System Assessment
Version 3, Issued 10/2011
cal-9
-30-cal-9
Special Process: Heat Treat System Assessment
Version 3. Issued 10/2011
‘The catayt fr pak performance
Section 3: Equipment
qWuoulssessy Wo)shg yeed) Jeo} :ss@2014 [e!2eds,
I Orr ro SSThe catalyst for peak performance
AIAG»
‘Special Process: Heat Treat System Assessment
Version 3. Issued 10/2011
cal-9
Jonvoo eqdeouse snonuuos pus agswome 9
poyonce
Jove pornos og yous sowed nosoure poi}
‘9 com nay poe ou 6 soos
pacn oe
yar owns Avadoud. §9°¢ won20s 4 peaL2806) eum pu sc}2/000B ay
poweu ow ‘Buroqucu pun onuco ns apnea
‘ou soe owes pue Lops Aees204 108)
‘sempcor
au 10 um co 04 4 poyods ea
uonouny dons
qa] "PARA Bae sem URE | OE
| jwunbo soca! oY
onsen
womy | Komersnes sow aMo3f00
hopes sou0pig an
arepouysp2en| eH sopeees {VIN
=
quoUIssessy Weys{g Jealy JOH :sse00Iq |eIDeds
32.cal-9
Special Process: Heat Treat System Assessment
Version 3. Issued 10/2011
The cata for peak performance
ee od ee
Jvepouun spoon] em | A
sourpna aanetao, souepine pue swwowenbos
‘eau
wearer,
= 1b
JWOWSS9Ssy WHO}5/S Jea1] WOH :sSeI01g [eIDeds,The catayyst for pesk performance
Special Process: Heat Treat System Assessment
Version 3, Issued 10/2011
sp senpornl Anum we |
psu un comesyraa om oy ap nog a
sZeonieojou mipean heopaedecnee| "Se occa a] HE
ropa fue tora nove jamie] gna alan ye og
Juuso sodas ayo pe ed anane| "ODUM OC
‘eoge ya por oun tind re xa Houoc|
os pres ma 30809 208 87
sousppa annosao
juowissassy weyshg 18911 Yeo} :sse2014 [eID0dg
34cal-9
Version 3, Issued 10/2011
we
ae
‘Special Process: Heat Treat System Assessment
oversees [wn ‘ouapna nn>s90
‘howernes
en
juowssassy wiyshg year) Jeo} :SS9D0N¢ JwID0ds,
Tre catayst or peak performanceThe catayst for peak performance
Special Process: Heat Treat System Assessment
cal-9
Version 3. Issued 102071
poyoanco pow ors
‘Arenewoine 298s GxyouonD vaervese,
{uuojno peavoiine oy) Ka parordde Aeayoods| snewoyne wos ypuenb =] gC
sean powoye st Suneuenb enue on uasade
‘ayeweyne ue 09 pee wos Youend 44
puny subsp goo a axauay pawnbos 3
etiojno og wo frasdde eBu0yo Ouveou3 |
suru yovond uy
+) pe yo Bureau oo; 20}
109, suoyate jee
-] 100 © one syns 04 8000)
24 pe 0 Buoy oo 1601 P00 woh
wowadeveu yo # ney regs 9} YK UA}
‘omevesaida
sawsorane pazuoyne fa pero
nejgertecoe 9 noqonnbo 0 soquou ABrou9 uy | ed
(suerte Guraecs]
oy soup 1 aun a (210 weopy '9BEH0%) wu]
'Afsoun sont vows erie y “pouyex]
‘| aupeus tee oj ogue oeube
owe oj ed 0 KB,000 ou] OF
janeo sy00 004 ou e209}
epmjonicn B99) 5,
ved yove yo Busosod ou i
juowssossy woyshg ery JeeH :ss9001d [eI98dg
36-cal-9
Special Process: Heat Treat System Assessment
Version 3, Issued 10/2011
The catayst for peek pertormence
pape
|
(ozzy
‘xis youn pa one ou Davee}
ue voqaedsa bos op ges ovo
oj dres soo wns oped ys res eu
Sad om ee
wauissossy wejehs weal JOH :ss9901 jeIoads
37-= AIAG
Special Process: Heat Treat System Assessment
Version 3. Issued 10/2011 The catalyst for peak performance
-38-AIAG 2a cas
Special Process: Heat Treat System Assessment
The catalyst for paok performance Version 3, issued 10/2011
3.1 Thermocouples
3.1.1 Application of Thermocouples: Thermocouples shall be selected as appropriate for their
intended use. Where a process is to be controlled, consideration shall be given to variables that can have
pact upon thermocouple performance such as, but not limited to, atmosphere, temperature, electrical
interference, etc.
Guidelines established for recommended temperature ranges or upper temperature limits for
thermocouples in publications such as ASTM E230, IEC 60584-1, or other national standards or by the
thermocouple manufacturer should be adhered to.
3.1.1.1 All thermocouples shall comply with Tables 3.1.1, 3.1.2, 3.1.3, 3.1.4 and 3.1.5 requirements.
3.1.1.2 Extension wire shall not be spliced. Only compensated jacks, plugs, connectors and terminal
strips may be used.
3.1.2 Calibration of Thermocouples: Thermocouples shall be calibrated traceable to the National
Institute of Standards and Technology (NIST) or other national institute of calibration, such as PTB
(Germany). A grace period of 2 weeks is allowed for all calibrations.
3.1.2.1 Thermocouples shall be calibrated in the temperature range in which they will be employed and
prior to first use. Calibration temperature intervals shall not exceed 150°C or 250°F. Refer to Tables 3.1.1,
3.1.2, 3.1.3, and 3.1.4 for appropriate thermocouple calibration and replacement requirements.
3.1.2.2 Calibration certificates shall include the following detail: the actual test temperature reading, the
nominal test temperature, the corresponding correction factor for each calibration temperature test point,
the provider of the calibration data, and the calibration method used.
3.1.2.3 The interpolation of correction factor values between calibration test points is allowed. No
determinations shall be made concerning values either above the highest calibration temperature or below
the lowest calibration temperature.
3.1.2.4 Extemal sources providing calibrations shall be accredited to ISO/IEC17025 or other national
equivalent. Internal sources providing calibrations shall do so in accordance with the intent of
ISO/IEC17025 or other national equivalent. Records shall be kept of training and qualifications for
internal personnel performing calibrations.
3.1.2.5 Thermocouples may be individually calibrated or made from calibrated rolls provided that both
ends of the roll are sampled and the accuracy requirements established in Tables 3.1.1, 3.1.2, 3.1.3, and
3.1.4 are satisfied.
3.1.3 Reuse of Thermocouples: The date that any thermocouple is placed in service shall be
documented. Requirements are indicated within 3.1 and Table 3.1.5.
3.1.3.1 A “use” for thermocouples is defined as one cycle of heating and cooling of the thermocouple
(see glossary). See Table 3.1.5 for maximum number of uses of a thermocouple.
-39-= AIAG 2a
Special Process: Heat Treat System Assessment
Version 3, ssued 10/2011 The catalyst for poak pertormanco
3.1.3.2 Damaged expendable or non-expendable base metal SAT and TUS thermocouples shall not be
reused,
3.1.3.3 For reuse of Type K and Type E test thermocouples, the depth of insertion shall be equal to, or
greater than, the depth of insertion of any previous use.AIAG 2 cats
: Heat Treat System Assessment
peek performance Version 3, ssued 10/2011
Table3.1.1 C:
ration and Replacement Requirements for Thermocouples Used for Control,
Monitoring and Recording.
ACen Ca Nacy Ue MOTTO
TYPE (1) Bau Loaw esl Og ACCURACY
a7 REQUIRED
Base Metal Types | 2 760°C (1400°F) | Calibrate before first use. | Primary or | + 1.1°C (+ 2.0°F)
(K.NJ.E) Replace Annually (2,3,5) | Secondary | or
Standard. | +0.4%
Base Metal Types. | < 760°C (1400°F) | Calibrate before Hist use, | primary or | #1.1°C (#2.0°F)
(KNJ.E) le, 35) si Secondary | 5 gag
- Standard.
Primary or £ 1.1°C (4 2.0°F)
Noble Metal Types Calibrate before firstuse. | Secondary | or
2 760°C (1400°F)
| RS) | esis Every Two Years | Seems” | Oy gag
1. Non-Expendable
Thermocouples shall be replaced whenever needed, e.g. failed SAT, or damaged thermocouple;
however, thermocouples shall be replaced minimally as stated above.
Base metal thermocouples shall not be recalibrated.
Nobel metal thermocouples Type B, R, and S may be reca
Does not apply to Load Sensing Thermocouples. See Tables
brated in lieu of replacement.
1.4 and 3.1.5
4lcake AIAG 2
Special Process: Heat Treat System Assessment
Version 3, Issued 10/2011 The catalyst for peak performance
Table 3.1.2 ~ Calibration and Replacement Requirements for Thermocouples Used for Primary
and Secondary Standards
a, Aaa es See eas | Bocduen
| . _ | is greater |
_ - ote
Seay aaa ma lemmas [rae [aor baes |
‘Standard (2) Noble Metal Thermocouple | Recalibrate each —_| Standard. or
| om
coy, [mm Vie Veto | een, ‘Latoazon
| | roars |
1 1
-42-
1 A primary standard thermocouple together with a primary standard instrument shall be used to
calibrate secondary standard thermocouples.
2. Use is limited to the calibration of temperature uniformity, system accuracy, controlling,
recording, monitoring, and load thermocouples.
3. A Type R or S noble metal thermocouple calibrated against a NIST (or equivalent) reference
standard, No error permitted.
4, Base metal thermocouples shall not be recalibrated.AIAG 2m ous
Special Process: Heat Treat System Assessment
Tho cata or poak performance Version 3, ssued 10/2011
Table 3.1.3 — Calibration and Replacement Requirements for Thermocouples Used for
Temperature Uniformity Survey (TUS) and System Accuracy Test (Sat)
THERMOCOUPLE Cea CaN) Co
aera oes Og Xe Y oa
ies eta)
Types B,R andS | Temperature Uniformity | Before first use. Replace or | Primary or £1.1°C (20°F) or
Noble Metal Surveys Recalibrate every 2 years, ‘Secondary 204%
| Standard
Types 8, R and $ Before first use. Replace or | Primary or | £1.19 (£ 20°F) or
Noble Metal SAT—Probe Method | Recalibrate every 2 years, Secondary 204%
_ Standard.
Types B, R and S SAT ~ Comparative | Before first use. Replace or | Primary or | £1.1°C (£2.0°F) or
Noble Metal Method Recalibrate per Table 3.1.1 | Secondary 204%
I Standard.
Base Metal Temperature Uniformity | Before first use. Replace per | Primary or £1.1°C (£2.0°F) or
Surveys Table 3.1.5 (1) ‘Secondary 204%
el fot Standard.
Base Metal Vaart easel Before frst use. Replace per | Primary or £1.1°C (£2.0°F) or
‘SAT—Probe Method | Table 3.1.5 (1) ‘Secondary £04%
| : on enna Standard.
Primary or
Base Metal SAT ~ Comparative | Before fist use. Replace per £1.1°C (£2.0°F) or
‘Secondary 9
Method Table 3.1.1 (1) sua 204%
1 Base metal thermocouples shall not be recalibrated.
-43-gous AIAG 2
Special Process: Heat Treat System Assessment
Version 3, Issued 10/2011 The catalyst for peak performance
Table 3.1.4- Calibration and Replacement Requirements for Thermocouple Used for Load
Sensing
Bouse ae ey Ue CALIBRATED OU)
aaa age IRON ad ST
(Nitiw7t REQUIRED
Types B, Rand S | Before first use. Replace or comes £1.1°C (£2.0°F) or
Noble Metal Recalibrate every six (6) ‘months Suniad | +0.4% |
Before frst use. Replace per Primary or - =
Base Metal Table 3.1.5 Recalibration Secondary way Peer)
- ___| prohibited. (1) __| Standard. . -
1 Base metal thermocouples shall not be recalibrated,
Table 3.1.5 — Allowable Number of Uses for Thermocouples in Specific Applications
lg=yM Le)
Blea AS SaaS a)
Temperature Uniformity Surveys /
| Expendable Base Metal | {ST 5 980°C (1800°F) 15
Expendable Base Metal aeesme Uniformity Surveys / |”, agoec (1800°F) 1
Expendable Base Metal | Control (1) : All : 1
Expendable Base Metal Monitor/Record/Load Sensing (4) > 650°C. crz00'ry | 1 |
Expendable Base Metal Monitor/Record/Load Sensing (4) 650°C (1200°F) | 30
‘Temperature Uniformity Surveys,
SAT and Load Sensing '$ 980°C (1800°F) 180 (2,3)
Thermocouples (5)
Non-expendable Base
Metal
44
Non-expendable Base
Metal
Temperature Uniformity Surveys,
SAT and Load Sensing > 980°C (1800°F) 90 (2,3)
| Thermocouples (5) 1
Includes Load Sensing Thermocouples used as a Control Thermocouple.
2. When a non-expendable base metal thermocouple is used above 980°C (1800°F), the maximum
total number of uses is 90 uses which shall include any previous or subsequent temperature
readings taken with the subject thermocouple.
3 In the absence of documentation of the number of uses for non-expendable base metal
thermocouple used for TUS and SAT, then the thermocouples shall be replaced after 6 months.
4. Expendable base metal thermocouples for load sensing, are allowed more than one use if
thermocouple shows no visual degradation. Documentation is required to show compliance.
5 Non-expendable base metal thermocouples for load sensing, are allowed more than one use if
thermocouple shows no visual degradation. Documentation is required to show compliance.AIAG a cals
‘Special Process: Heat Treat System Assessment
The cata for peak performance ‘Version 3, Issued 10/2011
3.2 Instrumentation
3.2.1 General Instrumentation Requirements: Instrumentation shall be selected as appropriate for
their intended use and shall meet or exceed the accuracy requirements indicated in Table 3.2.1.
3.2.1.1 All instrumentation calibrations shall be traceable to the National Institute of Standards and
Technology (NIST) or national or intemational standard,
3.2.1.2 Extemal sources providing calibrations shall be accredited to ISO/IEC17025 or other national
equivalent. Internal sources providing calibrations shall do so in accordance with the intent of
ISO/EC17025 or other national equivalent. Records shall be kept of training and qualifications for
internal personnel performing calibrations.
3.2.1.3 Calibration frequencies and accuracies are specified in the applicable Process Tables and in the
Instrumentation Table 3.2.1. A grace period of 2 weeks is allowed for all calibrations.
3.2.1.4 The temperature for each control zone shall be recorded by a recording instrument.
32141 Recorder shall be operating during the entire time that product is in the furnace
and print intervals/sample rates shall not exceed five (5) minutes for analog recorders and two (2)
minutes for digital recorders. Process record shall be legible.
3.2.2 Readal
ity and Resolution: The following represent minimally acceptable requirements:
3.2.2.1 Test instruments shall be digital and have a minimum readability of 1.0°C or 1.0°F.
3.2.2.2 At least one controlling, monitoring, or recording instrument for each furnace or oven zone shall
have a minimum readability of 1.0°C or 1.0°F for digital instruments or 2.0°C or 4.0°F for analog
recorders.
3.2.2.3 Temperature resolution requirements for digital and/or analog furnace chart recorders shall
comply with the following:
* 55°C maximum per centimeter of chart paper
* — 5°C maximum per chart line increment
* 250° maximum per inch of chart paper
10°F maximum per chart line increment
3.2.3 Offsets: The use of offsets is generally discouraged, however when used, a documented
procedure shall exist which at a minimum describes when their use is permitted, how to perform manual
and electronic offsets, how to document the basis for the offset (calibration, SAT or TUS), how to account
for the offset when performing calibrations, SAT’s or TUS’s and how to reintroduce any intentional
offsets.
The procedure shall also indicate who has the authority to approve the use of offsets and how this
approval is documented.
3.2.3.1 Offset or bias applied to the instrumentation calibration shall not exceed 2.0°C or 4.0°F.
-45-cate AIAG
Special Process: Heat Treat System Assessment a
Version 3. Issued 10/2011 The catalyst for peak performance
3.2.4 Calibration: Calibration of control, monitoring, and recording instruments shall be performed to
the manufacturer's instructions; however calibration may be performed as described in 3.2.4.1
3.2.4.1 For the calibration of control, monitoring or recording instruments on furnaces that are in
operation and running at typical operating temperatures, a single point calibration is acceptable
(parallel reading of thermocouple input). For furnaces with a load in process, the furnace
temperature shall remain within processing tolerance.
3.2.42 For each channel or group of channels in use that can be altered or adjusted, a calibration shall be
required.
3.2.43 Calibration Frequency of the control, monitoring, and recording instruments shall be one of the
‘wo options listed below:
3243.1 Option 1; Quarterly (single-point or multi-point calibration; see Glossary for
definitions)
3243.2 Option 2: the frequency may be semi-annual provided that the SAT is performed
quarterly per Probe Method A (per
employed for the instrument calibra
4.1) AND the multi-point calibration is
nm
3.2.5. Calibration Records: Calibration status and results shall be reported as follows.
3.2.5.1 A calibration label shall be affixed to the instrumentation device, or in the case of panel mounted
control, monitoring or recording instrumentation, on the device or as near as practical to the
device(s) to indicate its (their) most recent successfull calibration. The label(s) at a
shall include:
. Date the calibration was performed.
Due date of the next calibration.
Technician who performed the calibration (initials are acceptable)
Serial number of instrument
3.252 Instrumentation calibration results shall be documented. The instrument calibration report
or certificate shall include the following information:
Fumace or unit identification number
Make, model and serial number of instrument calibrated (not applicable to PLC
controlling devices).
Standard or test instrument used during calibration.
Method of calibration.
Ambient temperature and humidity
Required accuracy.
Initial and final values at each calibration point (if no adjustment is made then the final
value will equal the initial value).
Initial and corrected offseU/bias values (if no adjustment is made then the corrected
offset/bias value will equal the initial value).
‘Statement of acceptance
Any limitations or restrictions of the calibration
Date the calibration was performed.
Due date of next calibration.
Technician who performed the calibration.AIAG cats
Special Process: Heat Treat System Assessment
The catat ker paok portance Version 3, lseued 10/2011
© Signature of the technician who performed the calibration.
* Calibration company if not performed in-house.
+ Sign-off by responsible person in the heat treat organization.
3.2.6 Electronic Records: When using a system that creates electronic records the system shall create
write-once, read-only electronic records that cannot be altered without detection.
-47-“8h
syuownasuy
updo
410 Burowwons
(40) 000 ono
swuawnasuy
swoudnbo Cupooee
fussonoid feuuoun Jo anjeiodwr xn 40 BusoWON
Syyonvon pue ‘Suipioces ‘Buunseas opawwin | (4e0'P3) 0002 ¥ ono
stonins
joyunainyesadway pe 1 Koemo3e rwoungeu
twojs4s jo soueWNojed ‘uoneageo YwaLINASU puepues so)
Burpioaa 0 Buoy "Buss ope Avopuooeg 10 feu
2, eigened snLivs
og
Sujpiooe 0 ‘Buuoyow ‘Buyjomuoo pue “I08Ue5
peor s106008 38) Kanne Avuojuneunezodo} | seees6 8 oAaKoUM 1uorennba so
Siosues 9} Aoeunaae worsAs “suounasut | “BuIpee. 0 %500 sou prepues
389) pay o UogesqesAes09e 01 Pa 20 (46603) 0:20 prepuers ewe a ayewonUrDd Asepu000S
sosues
pue Arewd pue sive propues
vepuooes Jo vonesare9 Kore0ge 20lat03) 9.5007 | pIEPUEIS €ov8:0/%5 oe fr
prepueis puepuers fevoneN eoueioas prepueis
neo prepuers Keund orpemun | NZOSIW01SINId | wejeAMbe 40 1SIN oe a6ey0n 100827 s5v0j08
er eE TT)
Pee
Dona)
Fey
CENT)
TCT
gonad
Deon AZ)
aba
AdAL
PETC)
PETC)
SINFNAMINOAY NOLLVAGITVS LNAWAMLSNI ~ PTE ATAVL
AR HOOT 1 FHI OL,
<= OvIV
1402/01 panss) ‘¢ voIsion,
juowssossy wa}shs ead) Ja} :SSe204q [e/90dS
6109AIAG 2m cai
Special Process: Heat Treat System Assessment
The cata for peak performance Version 3, Issued 10/2011
3.3 System Accuracy Test (SAT)
3.3.1 The SAT shall be made in accordance with 3.3, and the System Accuracy Test Table 3.3.1
requirements.
3.3.2 The SAT shall be performed using a test thermocouple conforming to the requirements of
Thermocouple Table 3.1.3 coupled with a test instrument meeting the requirements of Instrumentation
Table 3.2.1
3.3.3. A new SAT shall be performed after any maintenance that could affect the SAT accuracy, e.g.,
the replacement of the lead wire, control thermocouple, or the replacement of the control instrument,
3.34 The SAT shall be performed while the furnace is operating at a typical operating temperature
using either the Probe Method (Section 3.3.4.1 or Section 3.3.4.2) or the Comparative Method (Section
33.43).
3.3.4.1 Probe Method A:
334.11 Probe Method A is a check between the uncorrected reading of the control
temperature system (control instrument, leadwire, and thermocouple) and the corrected reading of
a test temperature system (test instrument and test thermocouple). See Illustration 3.4.1
33.4.1.2 The tip (measuring junction) of the test thermocouple shall be no further than SO
mm (2 inches) from the tip (measuring junction) of the control thermocouple. Existing furnaces
that have physical limitations preventing compliance to the 50 mm tip-to-tip distance shall be
reviewed and approved by the assessor.
334.13 The temperature indication of the control instrument connected to the control
thermocouple shall be within +/- 5°C (or +/- 10°F) of the corrected temperature indication of the
test thermocouple on a test instrument. After insertion of the test thermocouple, allow sufficient
time to achieve equilibrium between the test thermocouple and the control thermocouple.
334.14 If the calculated SAT difference exceeds 5°C (10°F) the appropriate corrective
action shall be taken before commencing with additional thermal processing. Control
thermocouples failing to meet the requirements shall be replaced. A new SAT shall be conducted
on the replacement thermocouple. Actions taken shall be documented.
‘Note that when using Probe Method A, any electronic offset value introduced
into the control instrument for the purpose of centering a TUS result shall be
included in the SAT difference calculations.
334.15 SAT frequency shall be quarterly.
~49-ome AIAG 2
Special Process: Heat Treat System Assessment
Version 3, Issued 10/2011 ‘The catalyst for peak performance
Example of Probe Method '
Ove mp
Thermocouple
Controt
Thermocouple —~
(A) Control instrument
Part or Raw
Material
Chart Record
Furnace
Thermocouple Furnace Wall Work Zone
(8) Test Instrument
Lead Wire
EXAMPLE OF ACCEPTABLE SYSTEM ACCURACY TEST (SAT) PROBE METHOD - A
Cos Mag Rissa ile Mcsos Sees
Sree gm ATs Cal
ey eu a Sonat
ae oul) Bec
Se Nt a
cy Cy thes diggs orc one)
ro Co) er)
901.5°C
(1652°F) (1655°F)
+40.1°C 901.1°C -1.4°C
(1.0°F) (+0.2°F) (1654.2°F) (-2.2°F)
-50-
a ee ee ee oeAIAG a cats
Special Process: Heat Treat System Assessment
The catalyst for peak performance Version 3. ssued 10/2011
3.3.4.2 Probe Method B:
334.21 The Probe Method B is a comparison between the uncorrected reading of the
control temperature thermocouple indicated on a test instrument and the corrected reading of a
test temperature system (test instrument and test thermocouple). See Illustration 3.4.2
33.422 The tip (measuring junction) of the test thermocouple shall be no further than 50
mm (2 inches) from the tip (measuring junction) of the control thermocouple. Existing furnaces
that have physical limitations preventing compliance to the 50 mm tip-to-tip distance shall be
reviewed and approved by the assessor.
33.423 After insertion of the test thermocouple sufficient time shall be allowed to
achieve equilibrium between the test thermocouple and the control thermocouple under test.
334.24 The uncorrected reading of the control thermocouple connected to a test
instrument shall be recorded at the highest point in its temperature cycle. Immediately following,
the test instrument shall be connected to the test thermocouple. The corrected reading of the test
temperature system shall be recorded at the highest point in its temperature cycle,
33.425 If the calculated SAT difference between the uncorrected reading of the control
temperature thermocouple indicated on the test instrument and the corrected reading of the test
temperature system (test instrument and test thermocouple) exceeds +5°C (+10°F) the control
temperature thermocouple shall be replaced and any other appropriate corrective actions shall be
taken before commencing with additional thermal processing. All actions taken shall be
documented.
33.426 SAT frequency shall be quarterlygals AIAG 2m
Special Process: Heat Treat System Assessment
Version 3. issued 10/2011 The catalyst for peok performance
Example of Probe Method "B"
Controt
‘Thermocouple
=
Control Instrument
Over-Temp
Protection
Part or Raw
Material
Test Furnace
Sf Wall Work Zone
ls C om resi Thermocouple Furnace
K__ecment
Lead Wire
(A) Test Instrument
EXAMPLE OF ACCEPTABLE SYSTEM ACCURACY TEST (SAT) PROBE METHOD - B
Coe a
arte gh og tau Ey Matias saya
Seat mT Bad
Deas Pati fchrot aa Aare aI LO aha poe lea
eeu ea a
Ra ) AN ee OuC) ee
a ) er)
go0°c
|__(1652°F)
901.5°C
(1655°F)
+0.1°C 901.1°C
(+0.2°F) (1654.2°F)
Note: Test Instrument A and Test Instrument B are typically the same test instrument.AIAG» cats
‘Special Process: Heat Treat System Assessment
The cata or peak performance Version 3, Issued 10/2011
3.3.4.3 Comparative Method:
33.43. The Comparative Method is a comparison between the uncorrected reading of the
control temperature system (control instrument, leadwire and thermocouple) and the uncorrected
reading of any other permanently installed monitoring system (instrument, leadwire and
thermocouple) in the same work zone, such as an over temperature control system. See
Mlustration 3.4.3
33432 ‘The temperature difference (delta) between the control system (control
instrument, leadwire and thermocouple) reading and the reading of any other permanently
installed monitoring system, at the time of the most recent conforming instrument calibration test,
shall be established (e.g., the control temperature system indicates 600°C and the over
temperature control system indicates 605°C; the delta between these two devices is +5°C).
3.3433 This established delta shall not differ by more than +/-1°C (or +/-2°F) when
checked at a typical operating temperature. It is strongly recommended that the comparative
check be performed at or near the original comparison test temperature. See example below for
calculation of delta,
33434 If both devices have their respective thermocouples in the same protection tube
they shall be of a different type (e.g., Type K with Type N, Type R with Type S). This is to
prevent false readings due to similar degradation rate.
33.435 Corrective actions shall be taken to correct a failed SAT before commencing with
additional thermal processing. A new delta shall be established after any maintenance that could
affect the SAT accuracy, e.g., the replacement of the lead wire, thermocouple, control instrument,
or calibration adjustment for either the control temperature device or temperature monitoring
system. Actions taken shall be documented.
3.3.4.3.6 See Table 3.1.3, SAT Comparative Method for the resident thermocouple
replacement schedule.
3343.7 SAT frequency shall be monthly.
“53cal-9
The catalyst for pook performance
Example of Comparative Method
Contro!
‘Thermocouple
(AD) Control instrument
- Over-Temp
a | =
Part or Raw
Material
Chart Recorder
Resident
herm
(B,E) Resident Thermocouple
Thermocouple Monitor
Furnace
Furnace Wall Work Zone
Note 1: It is recommended that the comparative check be perform:
the time of instrument calibration (See A & B temperatur
at or near the initial temperature at
‘example below).
Note 2: Resident thermocouple and over-temp thermocouple may be the same thermocouple
EXAMPLE OF ACCEPTABLE SYSTEM ACCURACY TEST (SAT) COMPARATI
E METHOD
eer encery nm i
arr a a Ro
Asa Prien aT La oe
; bases BE
Toasts MONTHLY ele as
ory sod Crag é
oUt Tag ray
“ @) 4 bt
c) Orr)
600°C 605°C +c | 606°C 610°C
(1112°F) (1121°F) (+9°F) (1123°F) (1130°F)
Deviation from the initial delta D-CAIAG a cars
Special Process: Heat Treat System Assessment
The catalyst for pack performance Version 3, Issued 10/2011
335
‘System Accuracy Test Records shall include the following:
Identification of the thermocouple being tested
Identification of the test thermocouple
Identification of the test instrument
Date and time of day of the test
Observed control instrument reading
Observed test instrument reading
Test thermocouple and test instrument correction factors
Corrected test instrument reading
Calculated system accuracy test difference
Indication of test acceptance or failure
Identification of technician performing the test
Extemal calibration company if applicable
Sign-off by responsible person in the heat treat organization
-55-cal-9
Special Process: Heat Treat System Assessment
Version 3, issued 10/2011
AIAG
The catalyst for peak performance
TABLE 3.3.1 SYSTEM ACCURACY TEST REQUIREMENTS,
METHOD
Probe Method
BN nos
ata
Types B, Rand S
Noble Metal
Types K, N, J and €
Base Metal
GETS
ANN
Giolla load
Quarterly
PS
Nees
ALLOWED
£5.0°C (+ 10.0°F)
(1.3)
Comparative
Method
Types 8, Rand S
Noble Metal
Types K.N,J and E
Base Metal
Monthly
£1.0°C (£20)
(2,3)
1. Maximum value of the Calculated SAT difference (see 3.3.4.1.3 and 3.3.4.2.5).
2. Maximum deviation from initial delta (see 3.3.4.3.2)
Total offseU/bias assigned to the correction of a SAT error shall not exceed 2.0°C (4.0°F). This
permissible offset/bias is separate from offset/bias assignable to a Calibration error or TUS.
-56-AIAG cats
Special Process: Heat Treat System Assessment
The cata for poak performance Version 3. ssued 10/2011
3.4 Temperature Uniformity Surveys (TUS)
34.1 General TUS Requirements: Temperature uniformity characteristics, qualified work zones, and
operating temperature ranges of furnaces or ovens are validated by performing a TUS.
The TUS shall be performed in accordance with the appropriate Process Table and the requirements of
this section,
3.4.1.1 Any furnace modification or repair that could alter the temperature uniformity characteristics of
the furnace shall result in a temperature uniformity survey being performed prior to the furnace system
being used for processing. See “Furnace Modifications” and “Furnace Repairs” in the Glossary for further
guidance.
3.4.1.2 All furnace modifications or repairs shall be documented and include the determination made by
the responsible authority within the organization as to whether these modifications or repairs could alter
the temperature uniformity characteristics of the furnace.
3.4.1.3 TUS Test Temperatures: If the operating temperature range of the qualified work zone is equal
to or less than 170°C (305°) then only one temperature within the operating temperature range is
required to be tested. If the operating temperature range of the qualified work zone is greater than 170°C
(305°F) then the minimum and maximum temperatures of the operating temperature range shall be tested.
For aluminum heat treating, a tighter temperature range is given in Process Table C, C2.4.
34.14 TUS Furnace Parameters: When performing any temperature uniformity survey the furnace
system parameters during the test shall replicate the furnace system parameters during normal production.
If atmospheres used during production present safety risks or could affect the accuracy of test
thermocouples during a TUS an atmosphere of air or inert gas may be used.
The TUS may be performed with an empty furnace. If the furnace is empty then the thermocouples shall
be attached to a fixture to insure required test locations are securely held.
If the TUS is performed with a loaded furnace the load shall replicate typical operations and the
thermocouples shall be attached to or buried in the load,
3.4.1.5 Use of Heat Sinks: If the TUS is performed without a load the TUS test thermocouples may be
attached to or inserted into heat sinks, however the heat sink shall represent the typical section size of the
heat treated product. In addition, the heat sink shall possess similar heat transfer characteristics of the
material that is typically processed in the furnace under test.
3.4.1.6 Furnace Vacuum Level during TUS: The furnace vacuum shall be run at the lowest set point
employed in normal production but need not be less than 1 micron Hg (1 x 10° Torr, or 1.3 x 107
millibar) when performing a TUS.
3.4.2 Continuous and Semi-Continuous Furnaces
icals AIAG 2a
‘Special Process: Heat Treat System Assessment
Version 3, Issued 10/2011 ‘Tho catalyst for peak performance
3.4.2.1 TUS Methods: Continuous and semi-continuous furnaces shall be surveyed so that the volume
defined as the qualified work zone is tested. TUS test sensors shall be arranged either three dimensionally
(Volumetric Method) or in a plane (Plane Method).
3.4.2.2 Number and Location of TUS Thermocouples
3.4.2.2.1Volumetric Method: Shall be used with continuous pusher furnaces. See Table 3.4.1 for
number of TUS thermocouples. See Figure 3.4.1 for the location of the TUS thermocouples.
3.4.2.2.2Plane Method: Shall be used for continuous furnaces where the product is continuously
moving through the furnace, e.g,, belt furnaces. See Table 3.4.2 for number of thermocouples.
Refer to table 3.4.2 for the location of the TUS thermocouples.
3.4.3. TUS Data Collection:
3.4.3.1 TUS test thermocouples shall be traversed through the furnace at a traverse speed typically used
in production and representing all test locations as required in Table 3.4.1 and Figure 3.4.1 or Table 3.4.2
as appropriate.
3.4.3.2 Data collection shall begin when the TUS test thermocouples are loaded into the furnace.
All temperature data generated by the TUS test thermocouples shall be recorded automatically at least
every thirty seconds. The process record for furnace zone temperature shall be compared to the TUS data
to ensure compliance to TUS requirements. Manual data collection is not allowed.
TUS data collected shall clearly show the soak period achieved so that the responsible Quality Assurance
organization can determine compliance with internal process specifications defining suitable soak time.
3.44 Furnaces Other Than Continuous or Semi-Continuous
3.4.4.1 Number of TUS Thermocouples: The required number of TUS thermocouples shall be in
accordance with the TUS Test Thermocouple Table 3.4.1.
3.4.4.2 Location of TUS Thermocouples: See Figure 3.4.1 for the typical location of thermocouples in
rectangular and cylindrical shaped furnaces. For furnace work zone volumes greater than 8.5m’ (300ft*),
the thermocouple locations shall be similar to the example in Figure 3.4.1 and the additional
thermocouples shall be located to best represent the qualified work zone.
3.4.4.3 TUS Data Collection: Data collection shall begin when the TUS thermocouples are loaded into
the furnace. All temperature data generated by the TUS thermocouples and recorded on the process record
for furnace zone temperature shall be recorded automatically at a frequency of at least one set of readings
‘every two minutes for the duration of the survey. Manual data collection is not allowed.
The process record for furnace zone temperature shall be compared to the TUS data to ensure compliance
to TUS requirements.
3.4.4.3.1When the furnace temperature control achieves set point temperature, displaying a
normal control cycling around set point, and the TUS test thermocouples have stabilized, then the
‘TUS data collection shall continue for an additional thirty minutes minimum.
-58-AIAG cals
Special Process: Heat Treat System Assessment
The cata for poak performance Version 3, Issued 10/2011
3.4.5. Alternative TUS Testing Methods: Design characteristics of certain furnaces may prevent the
traversing or insertion of TUS test thermocouples through or into the furnace work zone(s).
In such instances it is incumbent upon the Heat Treater to develop acceptable alternative methods to
provide objective evidence that temperature uniformity characteristics of the thermal processing
equipment meet the requirements of the applicable Process Tables and satisfy the intent of this document.
The alternative approach taken shall be reviewed and approved by the customer.
3.45.1 Property Surveys: In the event an acceptable alternative TUS testing method cannot be
developed employing traversing or insertion of TUS test thermocouples through or into the furnace work
zone(8), property surveys shall be accepted as objective evidence of thermal processing capabilities,
Initial property surveys of the selected product shall analyze those characteristics that are sensitive to
variations in process temperatures and shall establish baseline data against which monthly product
property trends shall be performed. If possible the selected product is processed frequently. The normal
process size range shall be represented in the selected product. When a two-step process is under review,
the second step can be run on the samples independent from the remainder of the lot.
If the furnace qualified operating temperature range is equal to or less than 170°C (305°F), the highest and
lowest operating temperatures shall be represented by the product property survey. If the furnace qualified
operating temperature range is greater than 170°C (305°F), the product property surveys shall include an
intermediate temperature in addition to the highest and lowest operating temperatures.
At least five product property surveys shall be performed at each survey temperature. Samples for product
property surveys shall be taken from the extremes and center of the load.
Monthly property survey trends shall include selected characteristics of heat-treated product analyzed by
an appropriate statistical technique. Trends shall be examined monthly with defined control limits.
Processing will be halted if any property trend exhibits a shift beyond assigned control limits until the
cause of the shift is corrected.
3.4.6 Permissible TUS Test Thermocouple Failures: The permissible TUS test thermocouple
failure rate is defined below:
‘When using 3 to 9 thermocouples (0 failures are permitted
When using 10 to 16 thermocouples 1 failure is permitted
When using greater than 16 thermocouples | Less than or equal to 10%
failures
A temporary condition such as a short or loose connection where normal temperature readout is restored
shall not be considered a failed TUS test thermocouple. No corer position failures of a TUS test
thermocouple are allowed.
3.4.7. TUS Pass/Fail Requirements:
3.4.7.1 A temperature uniformity survey shall be acceptable if all previous requirements are met
including the following:
-59-cal-9
Special Process: Heat Treat System Assessment AIAG.
Version 3. Issued 10/2011 The catalyst for poak performance
All readings of all TUS thermocouples and control thermocouples are within the respective
temperature tolerance requirements shown in the applicable Process Table during the defined
soak period and the upper temperature tolerance was not exceeded at any time.
The time required achieving recovery, stabilization or recurrent temperature pattern did not
exceed the time limit specified in any applicable process specifications. TUS is run for the
minimum required time.
The organization’s internal process specification defining suitable soak time was met.
Internal process specification shall define suitable soak time at temperature requirements.
3.4.7.2 Reaction to TUS Failures: If the temperature uniformity tolerance is not within the established
limits in the applicable Process Table, the cause of the deviation shall be determined and documented.
The equipment shall not be used for additional processing until the cause has been corrected and the TUS
has been performed successfully.
348
meeting the requirements of Table 3.2.1
3.4,
temperatures of the operating temperature range shall be resurveyed.
TUS Instrumentation: TUS’s shall be performed using independent test instrumentation
Instrument Calibration Requirements and independent test
thermocouples meeting the requirements of Table 3.1.3 — Thermocouples.
‘Compensation for known deviations in the test instrumentation shall be made by electronic or
mathematical corrections.
34.9
report:
wee.
TUS Report: The items listed below shall be included in the temperature uniformity survey
Furnace identification name or number.
Method of TUS.
Survey test temperature(s).
TUS thermocouple quantity and location identification including a detailed diagram in three
dimensional space, or detailed description or photograph(s) of any load, rack or set-up.
TUS thermocouple calibration report to include correction factors.
Survey test instrument calibration report to include calibration data and correction factors for
each adjustable channel or input.
Corrected readings of all TUS thermocouples at each survey temperature. Readings shall be
identified as corrected or uncorrected.
Any limitations or restrictions of the TUS.
Testing company identification (if not performed in-house).
Name & Signature of the technician performing the TUS.
Survey start / stop time and start / stop date.
‘The data collection period or soak period as applicable shall be identified.
Survey test instrument identification number.
1 If the correction takes the form of adjusting (offsetting) the control instrument,
and if the Qualified Operating Temperature Range does not exceed 170°C (305°F) a resurvey is
not required, but the adjustment shall not exceed the limits of 2°C or 4°F. If the Qualified
Operating Temperature Range exceeds 170°C (305°F) then the minimum and maximum