MSDS Protectol PE
MSDS Protectol PE
Page: 1/14
BASF Safety data sheet according to Regulation (EC) No. 1907/2006 as amended from time to time.
Date / Revised: 23.06.2015 Version: 2.2
Product: Protectol® PE
(ID no. 30063180/SDS_GEN_EU/EN)
Date of print 17.09.2015
Protectol® PE
Chemical name: 2-phenoxyethanol
CAS Number: 122-99-6
1.2. Relevant identified uses of the substance or mixture and uses advised against
For the detailed identified uses of the product see appendix of the safety data sheet.
Company:
BASF SE
67056 Ludwigshafen
GERMANY
Operating Division Care Chemicals
For the classifications not written out in full in this section the full text can be found in section 16.
Pictogram:
Signal Word:
Warning
Hazard Statement:
H319 Causes serious eye irritation.
H302 Harmful if swallowed.
No specific dangers known, if the regulations/notes for storage and handling are considered.
Chemical nature
2-phenoxyethanol
CAS Number: 122-99-6
EC-Number: 204-589-7
INDEX-Number: 603-098-00-9
For the classifications not written out in full in this section, including the indication of danger, the
hazard symbols, the R phrases, and the hazard statements, the full text is listed in section 16.
3.2. Mixtures
Not applicable
If inhaled:
Keep patient calm, remove to fresh air, seek medical attention.
On skin contact:
Wash thoroughly with soap and water.
On ingestion:
Immediately rinse mouth and then drink 200-300 ml of water, seek medical attention.
4.2. Most important symptoms and effects, both acute and delayed
Symptoms: The most important known symptoms and effects are described in the labelling (see
section 2) and/or in section 11., Further important symptoms and effects are so far not known.
Page: 4/14
BASF Safety data sheet according to Regulation (EC) No. 1907/2006 as amended from time to time.
Date / Revised: 23.06.2015 Version: 2.2
Product: Protectol® PE
(ID no. 30063180/SDS_GEN_EU/EN)
Date of print 17.09.2015
4.3. Indication of any immediate medical attention and special treatment needed
Treatment: Treat according to symptoms (decontamination, vital functions), no known specific
antidote.
Further information:
The degree of risk is governed by the burning substance and the fire conditions. Contaminated
extinguishing water must be disposed of in accordance with official regulations.
Suitable materials for containers: Stove-lacquer RDL 50, glass, High density polyethylene (HDPE),
Low density polyethylene (LDPE), tinned carbon steel (Tinplate)
Further information on storage conditions: Keep container tightly closed in a cool, well-ventilated
place. Keep under nitrogen. Protect from atmospheric humidity.
122-99-6: 2-phenoxyethanol
122-99-6: 2-phenoxyethanol
freshwater: 0.943 mg/l
marine water: 0.0943 mg/l
intermittent release: 3.44 mg/l
sediment (freshwater): 7.2366 mg/kg
sediment (marine water): 0.7237 mg/kg
soil: 1.26 mg/kg
STP: 24.8 mg/l
122-99-6: 2-phenoxyethanol
worker: Long-term exposure - systemic and local effects, Inhalation: 8.07
mg/m3
worker: Long-term exposure- systemic effects, dermal: 34.72 mg/kg
consumer: Long- and short-term exposure - local effects, Inhalation: 2.5 mg/m3
consumer: Long-term exposure- systemic effects, dermal: 20.83 mg/kg
consumer: Long- and short-term exposure - systemic effects, oral: 17.43 mg/kg
Hand protection:
Chemical resistant protective gloves (EN 374)
Suitable materials also with prolonged, direct contact (Recommended: Protective index 6,
corresponding > 480 minutes of permeation time according to EN 374):
fluoroelastomer (FKM) - 0.7 mm coating thickness
Polyethylene-Laminate (PE laminate) - ca. 0.1 mm coating thickness
Suitable materials for short-term contact (recommended: At least protective index 2, corresponding >
30 minutes of permeation time according to EN 374)
nitrile rubber (NBR) - 0.4 mm coating thickness
Supplementary note: The specifications are based on tests, literature data and information of glove
manufacturers or are derived from similar substances by analogy. Due to many conditions (e.g.
temperature) it must be considered, that the practical usage of a chemical-protective glove in
practice may be much shorter than the permeation time determined through testing.
Manufacturer's directions for use should be observed because of great diversity of types.
Eye protection:
Safety glasses with side-shields (frame goggles) (e.g. EN 166)
Body protection:
Body protection must be chosen depending on activity and possible exposure, e.g. apron, protecting
boots, chemical-protection suit (according to EN 14605 in case of splashes or EN ISO 13982 in case
of dust).
Form: liquid
Colour: colourless
Odour: faint specific odour
Odour threshold:
not determined
pH value: 7
(10 g/l, 20 °C)
Melting point: 9.1 °C (Directive 92/69/EEC, A.1)
(1,013 hPa)
Boiling point: 244.3 °C (Directive 92/69/EEC, A.2)
decomposition point: > 350 °C (OECD Guideline 103)
Flash point: 126 °C (Directive 92/69/EEC, A.9,
closed cup)
Page: 7/14
BASF Safety data sheet according to Regulation (EC) No. 1907/2006 as amended from time to time.
Date / Revised: 23.06.2015 Version: 2.2
Product: Protectol® PE
(ID no. 30063180/SDS_GEN_EU/EN)
Date of print 17.09.2015
Evaporation rate:
not determined
Flammability: not flammable
Lower explosion limit: 1.4 %(V)
Upper explosion limit: 9.0 %(V)
Ignition temperature: 475 °C (DIN 51794)
Vapour pressure: 0.01 hPa
(20 °C)
Density: 1.11 g/cm3
(20 °C)
Relative density:
No data available.
Relative vapour density (air):
Heavier than air.
Solubility in water:
24 g/l
(20 °C)
Partitioning coefficient n-octanol/water (log Kow): 1.2 (OECD Guideline 107)
(23 °C; pH value: 7)
Self ignition: Based on its structural properties the
product is not classified as self-
igniting.
Substances to avoid:
strong oxidizing agents
Acute toxicity
Experimental/calculated data:
LD50 rat (oral): > 300 - 2,000 mg/kg
Experimental/calculated data:
LD50 rat (oral): 2,740 mg/kg (BASF-Test)
The European Union (EU) has classified this substance as 'harmful'.
----------------------------------
Irritation
Experimental/calculated data:
Skin corrosion/irritation rabbit: non-irritant (OECD Guideline 404)
Respiratory/Skin sensitization
Assessment of sensitization:
Skin sensitizing effects were not observed in animal studies.
Experimental/calculated data:
Guinea pig maximization test guinea pig: Non-sensitizing. (OECD Guideline 406)
Assessment of mutagenicity:
The substance was not mutagenic in bacteria. No mutagenic effect was found in various tests with
mammalian cell culture and mammals.
Carcinogenicity
Assessment of carcinogenicity:
No data available concerning carcinogenic effects.
Reproductive toxicity
Developmental toxicity
Assessment of teratogenicity:
Animal studies gave no indication of a developmental toxic effect at doses that were not toxic to the
parental animals.
Repeated dose toxicity and Specific target organ toxicity (repeated exposure)
Aspiration hazard
Toxicity to fish:
LC50 (96 h) > 100 mg/l, Pimephales promelas (Flow through.)
Aquatic invertebrates:
EC50 (48 h) > 100 mg/l, Daphnia magna (Directive 79/831/EEC, static)
Aquatic plants:
EC50 (72 h) > 100 mg/l (biomass), Scenedesmus subspicatus (DIN 38412 Part 9, static)
The product does not fulfill the criteria for PBT (Persistent/bioaccumulative/toxic) and vPvB (very
persistent/very bioaccumulative).
The product does not contain substances that are listed in Regulation (EC) 1005/2009 on
substances that deplete the ozone layer.
Contaminated packaging:
Uncontaminated packaging can be re-used.
Packs that cannot be cleaned should be disposed of in the same manner as the contents.
Page: 12/14
BASF Safety data sheet according to Regulation (EC) No. 1907/2006 as amended from time to time.
Date / Revised: 23.06.2015 Version: 2.2
Product: Protectol® PE
(ID no. 30063180/SDS_GEN_EU/EN)
Date of print 17.09.2015
SECTION 14: Transport Information
Land transport
ADR
Not classified as a dangerous good under transport regulations
UN number: Not applicable
UN proper shipping name: Not applicable
Transport hazard class(es): Not applicable
Packing group: Not applicable
Environmental hazards: Not applicable
Special precautions for None known
user
RID
Not classified as a dangerous good under transport regulations
UN number: Not applicable
UN proper shipping name: Not applicable
Transport hazard class(es): Not applicable
Packing group: Not applicable
Environmental hazards: Not applicable
Special precautions for None known
user
Sea transport
IMDG
Not classified as a dangerous good under transport regulations
UN number: Not applicable
UN proper shipping name: Not applicable
Transport hazard class(es): Not applicable
Packing group: Not applicable
Page: 13/14
BASF Safety data sheet according to Regulation (EC) No. 1907/2006 as amended from time to time.
Date / Revised: 23.06.2015 Version: 2.2
Product: Protectol® PE
(ID no. 30063180/SDS_GEN_EU/EN)
Date of print 17.09.2015
Environmental hazards: Not applicable
Special precautions for None known
user
Air transport
IATA/ICAO
Not classified as a dangerous good under transport regulations
UN number: Not applicable
UN proper shipping name: Not applicable
Transport hazard class(es): Not applicable
Packing group: Not applicable
Environmental hazards: Not applicable
Special precautions for None known
user
14.1. UN number
See corresponding entries for “UN number” for the respective regulations in the tables above.
14.7. Transport in bulk according to Annex II of MARPOL73/78 and the IBC Code
Regulation: Not evaluated
Shipment approved: Not evaluated
Pollution name: Not evaluated
Pollution category: Not evaluated
Ship Type: Not evaluated
Page: 14/14
BASF Safety data sheet according to Regulation (EC) No. 1907/2006 as amended from time to time.
Date / Revised: 23.06.2015 Version: 2.2
Product: Protectol® PE
(ID no. 30063180/SDS_GEN_EU/EN)
Date of print 17.09.2015
SECTION 15: Regulatory Information
15.1. Safety, health and environmental regulations/legislation specific for the
substance or mixture
If other regulatory information applies that is not already provided elsewhere in this safety data
sheet, then it is described in this subsection.
Information on intended use: This product is of industrial quality and unless otherwise specified or
agreed intended exclusively for industrial use. This includes the mentioned and recommended
usage. Any other intended applications should be discussed with the manufacturer. In particular this
concerns the application for products that are the object of special standards and regulations.
Full text of the classifications, including the indication of danger, the hazard symbols, the R phrases,
and the hazard statements, if mentioned in section 2 or 3:
Acute Tox. Acute toxicity
Eye Dam./Irrit. Serious eye damage/eye irritation
The data contained in this safety data sheet are based on our current knowledge and experience and
describe the product only with regard to safety requirements. The data do not describe the product's
properties (product specification). Neither should any agreed property nor the suitability of the product for
any specific purpose be deduced from the data contained in the safety data sheet. It is the responsibility
of the recipient of the product to ensure any proprietary rights and existing laws and legislation are
observed.
Vertical lines in the left hand margin indicate an amendment from the previous version.