Aq-G Relays: Features Typical Applications
Aq-G Relays: Features Typical Applications
ORDERING INFORMATION
AQG
Load current
1: 1 A
2: 2 A
Load voltage
2: 75 to 264 V AC
Type
1: Zero-cross (3,000 V)
2: Random (3,000 V)
Input voltage
05: 5 V DC
12: 12 V DC
24: 24 V DC
TYPES
Type Load current Load voltage Input voltage Part No.
5 V DC AQG12105
1A 75 to 264 V AC 12 V DC AQG12112
24 V DC AQG12124
Zero-cross
5 V DC AQG22105
2A 75 to 264 V AC 12 V DC AQG22112
24 V DC AQG22124
5 V DC AQG12205
1A 75 to 264 V AC 12 V DC AQG12212
24 V DC AQG12224
Random
5 V DC AQG22205
2A 75 to 264 V AC 12 V DC AQG22212
24 V DC AQG22224
Standard packing: Carton 20 pcs., Case 500 pcs.
ASCTB23E 201201-T1
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
2) Random type
Part No.
Item Type Remarks
AQG12205 AQG12212 AQG12224 AQG22205 AQG22212 AQG22224
Input voltage 4 to 6 V DC 9.6 to 14.4 V DC 19.2 to 28.8 V DC 4 to 6 V DC 9.6 to 14.4 V DC 19.2 to 28.8 V DC
Input impedance Approx. 0.3k Ω Approx. 0.8k Ω Approx. 1.6k Ω Approx. 0.3k Ω Approx. 0.8k Ω Approx. 1.6k Ω
Input *1
side Drop-out
1V
voltage, min.
Reverse voltage 3V
1A:
Ta = Max. 40°C 104°F
Max. load current 1 A AC*2 2 A AC*2
2A:
Ta = Max. 25°C 77°F
Load voltage 75 to 264 V AC
Frequency 45 to 65 Hz
Load
Non-repetitive
side 8 A*3 30 A*3 In one cycle at 60 Hz
surge current
Max. “OFF-state”
1.5 mA at 60 Hz at 200 V AC
leakage current
Max. “ON-state” at Max. carrying
1.6 V
voltage drop current
Min. load current 20 mA*4
Notes: *1. Refer to REFERENCE DATA “3. Input current vs. input voltage characteristics”.
*2. Refer to REFERENCE DATA “1. Load current vs. ambient temperature”.
*3. Refer to REFERENCE DATA “2. Non-repetitive surge current vs. carrying time”.
*4. When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”.
ASCTB23E 201201-T1
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
30
1.5 25
6
20
1A type
1.0 4 15
10
0.5 2
5
0 0 0
-30 0 20 40 60 80 1 10 100 1 10 100
Ambient temperature, °C No. of cycles at 60 Hz No. of cycles at 60 Hz
3. Input current vs. input voltage characteristics 4.-(1) Load current vs. ambient temperature 4.-(2) Load current vs. ambient temperature
characteristics for adjacent mounting characteristics for adjacent mounting
(1A type) (2A type)
30 1.2 2.5
=15 mm
25 1.0 .591 inch
2.0
Input current, mA
=10 mm
Load current, A
Load current, A
.394 inch
20 0.8 =15 mm
(5 V type) (12 V type) (24 V type) 1.5 .591 inch
=5 mm
.197 inch
15 0.6 =10mm
1.0 .394 inch
10 =5mm
0.4
.197 inch
0.5
5 0.2
DIMENSIONS (mm inch) The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
4-1.0 dia.
20.5 max. 4-.039 dia.
0.8 .807 max.
.031 Tolerance: ±0.1 ±.004
Schematic
4-0.7 1.2
4-1.6 4-.028 .047 0.25 Input Output
4-.063 3.7 .010 – +
2.54 10.16 7.62 .146
.100 .400 .300
ASCTB23E 201201-T1
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
ASCTB23E 201201-T1
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
Authorized Distributor
Panasonic:
AQG12105 AQG12112 AQG12124 AQG12205 AQG12212 AQG12224 AQG22112 AQG22124 AQG22205
AQG22212 AQG22224