0% found this document useful (0 votes)
54 views5 pages

Aq-G Relays: Features Typical Applications

This document provides information about AQ-G SSR relays for 1A and 2A control, including: - They are space-saving vertical SSRs with a maximum thickness of 4.5mm, reducing mounting space by 30% compared to conventional SSRs. - They feature a snubber circuit to prevent malfunction from rapid voltage rises in inductive loads and current. - They are available in zero-cross or random types, with 1A or 2A load currents, various input voltages, and can control loads from 75-264V AC.

Uploaded by

勝勝利
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
54 views5 pages

Aq-G Relays: Features Typical Applications

This document provides information about AQ-G SSR relays for 1A and 2A control, including: - They are space-saving vertical SSRs with a maximum thickness of 4.5mm, reducing mounting space by 30% compared to conventional SSRs. - They feature a snubber circuit to prevent malfunction from rapid voltage rises in inductive loads and current. - They are available in zero-cross or random types, with 1A or 2A load currents, various input voltages, and can control loads from 75-264V AC.

Uploaded by

勝勝利
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

AQ-G VDE

Slim type SSR for


1A and 2A control AQ-G RELAYS
FEATURES TYPICAL APPLICATIONS
1. Space saving, Vertical size with a • Household appliances such as air
maximum thickness of 4.5 mm. conditioners, refrigerators and
Mounting space has been reduced to humidifiers
30% (compared to conventional SSR’s) • Healthcare and medical equipment
while meeting high density PC board • Industrial machinery such as NC
mounting requirements. machines, mounters, injection
2. Snubber circuit preventing molders, and robots
malfunction • Microcomputer boards
3. Zero-cross type and Random type • Amusement and amenity related
available equipment
4. High dielectric strength of
3,000V AC
(between input and output)
5. Snubber circuit integrated
The snubber circuit is integrated to
prevent malfunction caused by the rapid
rise of voltage on the output side, such as
RoHS compliant inductive load and current.

ORDERING INFORMATION
AQG
Load current
1: 1 A
2: 2 A
Load voltage
2: 75 to 264 V AC
Type
1: Zero-cross (3,000 V)
2: Random (3,000 V)
Input voltage
05: 5 V DC
12: 12 V DC
24: 24 V DC

TYPES
Type Load current Load voltage Input voltage Part No.
5 V DC AQG12105
1A 75 to 264 V AC 12 V DC AQG12112
24 V DC AQG12124
Zero-cross
5 V DC AQG22105
2A 75 to 264 V AC 12 V DC AQG22112
24 V DC AQG22124
5 V DC AQG12205
1A 75 to 264 V AC 12 V DC AQG12212
24 V DC AQG12224
Random
5 V DC AQG22205
2A 75 to 264 V AC 12 V DC AQG22212
24 V DC AQG22224
Standard packing: Carton 20 pcs., Case 500 pcs.

ASCTB23E 201201-T1
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/

Free Datasheet http://www.Datasheet4U.com


AQ-G
RATING
1. Ratings (Ambient temperature: 20°C 68°F, Input voltage ripple: 1% or less)
1) Zero-cross type
Part No.
Item Type Remarks
AQG12105 AQG12112 AQG12124 AQG22105 AQG22112 AQG22124
Input voltage 4 to 6 V DC 9.6 to 14.4 V DC 19.2 to 28.8 V DC 4 to 6 V DC 9.6 to 14.4 V DC 19.2 to 28.8 V DC
Input impedance Approx. 0.3k Ω Approx. 0.8k Ω Approx. 1.6k Ω Approx. 0.3k Ω Approx. 0.8k Ω Approx. 1.6k Ω
Input *1
side Drop-out
1V
voltage, min.
Reverse voltage 3V
1A:
Ta = Max. 40°C 104°F
Max. load current 1 A AC*2 2 A AC*2
2A:
Ta = Max. 25°C 77°F
Load voltage 75 to 264 V AC
Frequency 45 to 65 Hz
Load
Non-repetitive
side 8 A*3 30 A*3 In one cycle at 60 Hz
surge current
Max. “OFF-state”
1.5 mA at 60 Hz at 200 V AC
leakage current
Max. “ON-state” at Max. carrying
1.6 V
voltage drop current
Min. load current 20 mA*4

2) Random type
Part No.
Item Type Remarks
AQG12205 AQG12212 AQG12224 AQG22205 AQG22212 AQG22224
Input voltage 4 to 6 V DC 9.6 to 14.4 V DC 19.2 to 28.8 V DC 4 to 6 V DC 9.6 to 14.4 V DC 19.2 to 28.8 V DC
Input impedance Approx. 0.3k Ω Approx. 0.8k Ω Approx. 1.6k Ω Approx. 0.3k Ω Approx. 0.8k Ω Approx. 1.6k Ω
Input *1
side Drop-out
1V
voltage, min.
Reverse voltage 3V
1A:
Ta = Max. 40°C 104°F
Max. load current 1 A AC*2 2 A AC*2
2A:
Ta = Max. 25°C 77°F
Load voltage 75 to 264 V AC
Frequency 45 to 65 Hz
Load
Non-repetitive
side 8 A*3 30 A*3 In one cycle at 60 Hz
surge current
Max. “OFF-state”
1.5 mA at 60 Hz at 200 V AC
leakage current
Max. “ON-state” at Max. carrying
1.6 V
voltage drop current
Min. load current 20 mA*4
Notes: *1. Refer to REFERENCE DATA “3. Input current vs. input voltage characteristics”.
*2. Refer to REFERENCE DATA “1. Load current vs. ambient temperature”.
*3. Refer to REFERENCE DATA “2. Non-repetitive surge current vs. carrying time”.
*4. When the load current is less than the rated minimum load current, please refer to “Cautions for Use of SSR”.

2. Characteristics (Ambient temperature: 20°C 68°F, Input voltage ripple: 1% or less)


Item Zero-cross type Random type Remarks
Operate time max. 1/2 cycle of voltage sine wave + 1 ms 1 ms
Release time, max. 1/2 cycle of voltage sine wave + 1 ms
Insulation resistance, min. 109 Ω between input and output at 500 V DC
Breakdown voltage 3,000 Vrms between input and output for 1 min.
Vibration resistance 10 to 55 Hz double amplitude of 0.75 mm X, Y, Z axes
Shock resistance Min. 1,000 m/s2 X, Y, Z axes
Non-condensing at low
Ambient temperature –30°C to +80°C –22°F to +176°F
temperatures
Storage temperature –30°C to +100°C –22°F to +212°F
Operational method Zero-cross (Turn-ON and Turn-OFF) Random turn ON, zero-cross turn OFF

ASCTB23E 201201-T1
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/

Free Datasheet http://www.Datasheet4U.com


AQ-G
REFERENCE DATA
1. Load current vs. ambient temperature 2.-(1) Non-repetitive surge current vs. carrying time 2.-(2) Non-repetitive surge current vs. carrying time
(1A type) (2A type)
2.5 10 40

Non-repetitive surge current, A


Non-repetitive surge current, A
35
2.0 8
2A type
Load current, A

30

1.5 25
6
20
1A type
1.0 4 15

10
0.5 2
5

0 0 0
-30 0 20 40 60 80 1 10 100 1 10 100
Ambient temperature, °C No. of cycles at 60 Hz No. of cycles at 60 Hz

3. Input current vs. input voltage characteristics 4.-(1) Load current vs. ambient temperature 4.-(2) Load current vs. ambient temperature
characteristics for adjacent mounting characteristics for adjacent mounting
(1A type) (2A type)
30 1.2 2.5
=15 mm
25 1.0 .591 inch
2.0
Input current, mA

=10 mm
Load current, A

Load current, A
.394 inch
20 0.8 =15 mm
(5 V type) (12 V type) (24 V type) 1.5 .591 inch
=5 mm
.197 inch
15 0.6 =10mm
1.0 .394 inch
10 =5mm
0.4
.197 inch
0.5
5 0.2

= Adjacent mounting pitch = Adjacent mounting pitch


0 0
0 5 10 15 20 25 30 35 -30 0 20 40 60 80 -30 0 20 40 60 80
Input voltage, V Ambient temperature, °C Ambient temperature, °C

DIMENSIONS (mm inch) The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/

1. 1A type External dimensions PC board pattern (Bottom view)


CAD Data 4.5 max. 1.2
24.5 max. .177 max. .047
2.54 10.16 7.62
.965 max. .100 .400 .300

0.8 13.5 max.


.031 .531 max. 4-1.0 dia.
4-.039 dia.

Tolerance: ±0.1 ±.004


4-0.7 1.2
4-1.6 4-.028 .047 0.25
4-.063 3.7 .010 Schematic
2.54 10.16 7.62 .146
.100 .400 .300 Input Output
– +

General tolerance: ±0.2 ±.008

2. 2A type External dimensions PC board pattern (Bottom view)


CAD Data 4.5 max. 1.2
24.5 max. .177 max. .047
2.54 10.16 7.62
.965 max. .100 .400 .300

4-1.0 dia.
20.5 max. 4-.039 dia.
0.8 .807 max.
.031 Tolerance: ±0.1 ±.004

Schematic
4-0.7 1.2
4-1.6 4-.028 .047 0.25 Input Output
4-.063 3.7 .010 – +
2.54 10.16 7.62 .146
.100 .400 .300

General tolerance: ±0.2 ±.008

ASCTB23E 201201-T1
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/

Free Datasheet http://www.Datasheet4U.com


AQ-G
Recommended Temperature Controllers
<KT4H Temperature Controller>
Our temperature controller is recommended for use with our Solid State Relays.
Features
• Space saving requiring only a depth of 65 mm
48mm • Data collection possible through a PLC using RS485 communication
1.890inch • Tool port is standard for easy data setting
• Inverted LCD + backlight for good legibility with large characters
56mm • Excellent operability and rich optional control functions
2.205inch
Substitute part numbers
48mm Power supply Control output Part No.
1.890inch
100 to 240 V AC Non-contact voltage output AKT4H112100
* For detailed product information about temperature controllers, please refer to our website:
http://industrial.panasonic.com/ac/e/

ASCTB23E 201201-T1
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/

Free Datasheet http://www.Datasheet4U.com


Mouser Electronics

Authorized Distributor

Click to View Pricing, Inventory, Delivery & Lifecycle Information:

Panasonic:
AQG12105 AQG12112 AQG12124 AQG12205 AQG12212 AQG12224 AQG22112 AQG22124 AQG22205
AQG22212 AQG22224

Free Datasheet http://www.Datasheet4U.com

You might also like