0% found this document useful (0 votes)
218 views4 pages

Em2c26clt Data

The document provides technical data for an EM 2C26CLT hermetic reciprocating compressor, including: 1) It is designed for 220-240V 50Hz power in low back pressure applications with an evaporating temperature range of -35°C to -10°C. 2) Performance data is given for cooling capacity, power consumption, current, gas flow rate, and efficiency at different evaporating temperatures and condensing temperatures. 3) Dimensions, weights, lubrication details, electrical characteristics, and approval certifications are also listed.

Uploaded by

Ruben Rodriguez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
218 views4 pages

Em2c26clt Data

The document provides technical data for an EM 2C26CLT hermetic reciprocating compressor, including: 1) It is designed for 220-240V 50Hz power in low back pressure applications with an evaporating temperature range of -35°C to -10°C. 2) Performance data is given for cooling capacity, power consumption, current, gas flow rate, and efficiency at different evaporating temperatures and condensing temperatures. 3) Dimensions, weights, lubrication details, electrical characteristics, and approval certifications are also listed.

Uploaded by

Ruben Rodriguez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

COMPRESSOR TECHNICAL DATA

COMPRESSOR DEFINITION
Designation EM 2C26CLT
Nominal Voltage/Frequency 220-240 V 50 Hz
Engineering Number 513304529
A - APPLICATION / LIMIT WORKING CONDITIONS
1 Type Hermetic reciprocating compressor
2 Refrigerant R-600a
3 Nominal voltage and frequency 220-240 / 50 [ V / Hz ]
4 Application type Low Back Pressure
4.1 Evaporating temperature range -35°C to -10°C (-31°F to 14°F)
5 Motor type RSCR
6 Starting torque LST - Low Starting Torque
7 Expantion device Capillary tube
8 Compressor cooling Operating voltage range
50 Hz 60 Hz
8.1 LBP (32ºC Ambient temperature) Static 198 to 255 V -
8.2 LBP (43ºC Ambient temperature) Static 198 to 255 V -
8.3 HBP (32ºC Ambient temperature) - - -
8.4 HBP (43ºC Ambient temperature) - - -
9 Maximum condensing temperature
9.1 Operating (gauge) 6.9 [kgf/cm²] (98 psig) / ºC - ºF
9.2 Peak (gauge) 7.8 [kgf/cm²] (111 psig) / ºC - ºF
10 Maximum winding temperature 130 [ °C ]
B - MECHANICAL DATA
1 Commercial designation 1/10 [hp]
2 Displacement 5.19 [cm³] (0.317 cu.in)
2.1 Bore [mm] 21.000
2.2 Stroke [mm] 15.000
3 Lubricant charge 150 [ml] (5.07 fl.oz.)
3.1 Lubricants approved
3.2 Lubricants type/viscosity MINERAL / ISO5
4 Weight (with oil charge) 8.21 [kg] (18.10 lb.)
5 Nitrogen charge - [kgf/cm²]

C - ELETRICAL DATA
1 Nominal Voltage/Frequency/Number of Phases 220-240 V 50 Hz 1 ~ (Single phase)
2 Starting device type TSD
2.1 Starting device TSD-220V
3 Start capacitor - [µF(VAC minimum)]
4 Run capacitor 2.5(300)/2(300)/3(300) [µF(VAC minimum)]
5 Motor protection 4TM110KFBYY-73
6 Start winding resistance 31.90 [W at 25ºC (77ºF)] +/- 8%
7 Run winding resistance 44.40 [W at 25ºC (77ºF)] +/- 8%
8 LRA - Locked rotor amperage (50 Hz) 2.00 [A] - Measured according to UL 984
9 FLA - Full load amperage L/MBP (50 Hz) 0.30 [A] - Measured according to UL 984
10 FLA - Full Load Amperage HBP (50 Hz) - [A] - Measured according to UL 984
11 Approval boards certification IRAM - VDE

UPDATE: 17SEP2010 513304529


COMPRESSOR TECHNICAL DATA

D - PERFORMANCE - CHECK POINT DATA

TEST CONDITIONS: ASHRAE LBP-NOFAN Evaporating temperature -23.3°C (-9.94°F)


@220V50Hz Static (Condensing temperature 54.4°C (129.92°F))
Power Current Gas flow EFFICIENCY RATE
Cooling capacity consumption consumption rate
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
[Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
283 71 83 46 0.21 6.10 1.54 1.79

E - PERFORMANCE - CURVES

TEST CONDITIONS: ASHRAE32-NOFAN (Condensing temperature 35ºC (+95ºF) )


@220V50Hz Static
Power Current Gas flow EFFICIENCY RATE
Evaporating Cooling capacity
consumption consumption rate
temperature
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 172 43 50 30 0.15 0.54 5.74 1.45 1.68
-30 (-22) 232 58 68 35 0.17 0.73 6.66 1.68 1.95
-25 (-13) 303 76 89 40 0.19 0.95 7.61 1.92 2.23
-20 (- 4) 387 98 114 45 0.21 1.22 8.68 2.19 2.54
-15 (+ 5) 490 123 143 49 0.23 1.54 9.95 2.51 2.92
-10 (+14) 612 154 179 53 0.25 1.93 11.50 2.90 3.37

TEST CONDITIONS: ASHRAE32-NOFAN (Condensing temperature 45ºC (+113ºF) )


@220V50Hz Static
Power Current Gas flow EFFICIENCY RATE
Evaporating Cooling capacity
consumption consumption rate
temperature
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 144 36 42 31 0.15 0.45 4.72 1.19 1.38
-30 (-22) 206 52 60 36 0.17 0.65 5.67 1.43 1.66
-25 (-13) 278 70 81 42 0.19 0.87 6.56 1.65 1.92
-20 (- 4) 362 91 106 48 0.22 1.14 7.47 1.88 2.19
-15 (+ 5) 462 116 135 54 0.25 1.45 8.48 2.14 2.49
-10 (+14) 581 146 170 60 0.27 1.83 9.68 2.44 2.84

TEST CONDITIONS: ASHRAE32-NOFAN (Condensing temperature 55ºC (+131ºF) )


@220V50Hz Static
Power Current Gas flow EFFICIENCY RATE
Evaporating Cooling capacity
consumption consumption rate
temperature
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 120 30 35 32 0.14 0.38 3.83 0.96 1.12
-30 (-22) 183 46 54 38 0.17 0.58 4.87 1.23 1.43
-25 (-13) 255 64 75 44 0.20 0.80 5.76 1.45 1.69
-20 (- 4) 338 85 99 51 0.23 1.06 6.58 1.66 1.93
-15 (+ 5) 436 110 128 59 0.26 1.37 7.40 1.87 2.17
-10 (+14) 551 139 162 66 0.30 1.74 8.32 2.10 2.44

UPDATE: 17SEP2010 513304529


COMPRESSOR TECHNICAL DATA

E - PERFORMANCE - CURVES

TEST CONDITIONS: ASHRAE32-NOFAN (Condensing temperature 65ºC (+149ºF) )


@220V50Hz Static
Power Current Gas flow EFFICIENCY RATE
Evaporating Cooling capacity
consumption consumption rate
temperature
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 98 25 29 33 0.14 0.31 2.98 0.75 0.87
-30 (-22) 163 41 48 39 0.17 0.51 4.19 1.06 1.23
-25 (-13) 235 59 69 46 0.20 0.74 5.15 1.30 1.51
-20 (- 4) 316 80 93 54 0.24 0.99 5.95 1.50 1.74
-15 (+ 5) 411 104 121 62 0.28 1.30 6.65 1.68 1.95
-10 (+14) 523 132 153 71 0.32 1.65 7.35 1.85 2.15

UPDATE: 17SEP2010 513304529


COMPRESSOR TECHNICAL DATA

F - EXTERNAL CHARACTERISTICS
1 Base plate European Standard EUEM
2 Tray holder No
3 Connectors
3.1 SUCTION 6.1 +0.10/+0.00 [mm] (0.240" +0.004"/+0.000")
3.1.1 Material Copper
3.1.2 Shape Slanted 42º up + 45° to Back
3.2 DISCHARGE 5.1 +0.10/+0.00 [mm] (0.201" +0.004"/+0.000")
3.2.1 Material Copper
3.2.2 Shape Slanted 48° up + 24° to Back
3.3 PROCESS 6 +0.08/-0.08 [mm] (0.236" +0.003"/-0.003")
3.3.1 Material Copper(OD)
3.3.2 Shape Slanted 43° up + 45° to Back
3.4 Oil cooler (Copper) No [mm]
3.5 Connector sealing Rubber Plugs

UPDATE: 17SEP2010 513304529