0% found this document useful (0 votes)
107 views1 page

Steel Pole Installation Guide

This document provides a list of materials needed for a project involving tension set shield wire or OPGW installation. It includes 12 bolts, 6 dead end clamps, 6 clevises, 6 eye nuts, 3 feet of insulator tie, 18 spring locks, and 36 flat washers. Notes provide specifications on pole dimensions, pre-drilled holes, markings, and installation instructions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
107 views1 page

Steel Pole Installation Guide

This document provides a list of materials needed for a project involving tension set shield wire or OPGW installation. It includes 12 bolts, 6 dead end clamps, 6 clevises, 6 eye nuts, 3 feet of insulator tie, 18 spring locks, and 36 flat washers. Notes provide specifications on pole dimensions, pre-drilled holes, markings, and installation instructions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

SAUDIARAMCO.

NOTES:
LIST OF MATERIAL
1. ALL DIMENSIONS ARE IN MILLIMETER UNLESS

102
TENSION SET
OTHERWISE SPECIFIED.
SHEILD WIRE OR OPGW DWG. ISSUE REQ'D. 2. POLES SHALL BE PRE-DRILLED WITH 20MM DIA HOLES
AMS # DESCRIPTION
CODE UNIT QTY. AT LOCATIONS SPECIFIED IN THIS DRAWING.

3. ALL PRE-DRILLED HOLES SHALL BE PROVIDED WITH


1 1000390097 EA 12 BOLT: MACHINE: 3/4" DIA 14" IN. LONG GALV
CAPS OR PLUGS (DURABLE PLASTIC OR COMPOSITE

OF
898
1000390607 MATERIALS).
5 2 EA 6 CLAMP, DEAD END, ALUMINUM FOR # 4/0 AWG TO # 2/0 AWG STRANDED
10 3 4 2

CONSENT
4. EARTHING NUT SHALL BE PROVIDED WITH BOLT AND
7 8 EA
( CAL FOR 6)
TYPI 3 1000391426 6 CLEVIS: INSULATOR CLEVIS, BALL, CURVED BRACKET MTG, FORGED WASHER.

CAL FOR 1
TYPI
( 8) 5. POLE SHALL BE PERMANENTLY MARKED WITH MANU-
4 1000393239 EA 6 CLEVIS: SOCKET EYE , 21 MM, 15.9 MM (5/8 IN) INSIDE WD, 35 MM INSIDE LG
FACTURERS NAME YEAR OF MANUFACTURE LEGNTH

EA 6 EYE; NUT, 3/4" SSZ. GALV. AND ULTIMATE LOAD RATING.


5 1000391984

127

TTEN
6. CONTRACTOR SHALL NOT INSTALL BOTTOM LINE
6 1000393964 FT 3 TIE, INSULATOR, SIDE IN CASE OF 1-PHASE 2-WIRES+SHIELD WIRE.

WRI
1
127 7 1000233194 EA 18 LOCK: WASHER, SPRING: FOR 3/4 IN. BOLT 7. POD POLE TAG MUST BE INSTALLED IN ALL POLES
BEARING THE POLE NUMBER AND INSTALLATION DATE
EA

THE
8 1000233149 36 WASHER: ROUND, FLAT FOR ƒ IN. BOLT
8. GALVANIZED STEEL POLE MUST BE COATED WITH
127

9 1000386822 EA 3 INSULATOR: LINE POST, TIE TOP ANTI-CORROSION COATING OF COAL TAR EPOXY

THOUT
AS PER 14-SAMSS-403.
10 1000387225 EA 12 INSULATOR: SUSPENSION
9. INSULATORS SHALL BE RATED ACCORDINGLY FOR
229

13 1000889281 EA

WI
11 1 POLE: STEEL, 55FT OR REQUIRED LENGTH 34.5kV SYSTEM
34.5kV SYSTEM.

10. REFER TO SAES-P-107, TABLE-1 FOR CONDUCTOR &


1220

12 1000386998 EA 3 STUD , POST INSULATOR, SHORT 3/4" DIA

NG
POLE CLEARANCE
POLE CLEARANCE.

DRAWI
254

13 1000366536 EA 3 CONNECTOR; COMPRESSION SLEEVE TYPE FOR 4/0 AWG CONDUCTOR 11. EITHER COMPOSITE OR PORCELAIN TYPE INSULATORS

MAY BE USED. REFER TO SAES-P-107 FOR DETAILS.


14 1000390451 EA 3 BRACKET, FOR POST INSULATOR
12. FOR 55' POLE, OTHER POLE HEIGHTS, MAKE

S
THI
15 08-513-446 EA 2 TAG; BRASS TAG ADJUSTMENT ACCORDINGLY. GUY WIRES SHALL BE
9 12 14 6
INSTALLED AT A TRUE ANGLE OF 45Deg. TO THE
( CAL FOR 3)
TYPI VERTICAL. IN AREAS WHERE IS NOT FEASIBLE DUE

FROM
TO SITE CONDITIONS, A MINIMUM ANGLE OF 37 Deg
SHALL BE ADOPTED.

NED
OBTAI
254

BE
PART,SHALL
127
229

13
1220

REFERENCE DRAWINGS

N
I
FULL,OR
254

N
I ON
11

REPRODUCTI
127

SAUDIARAMCO.NO
127
864

127

GUY AND ANCHOR


229

13

OF
254

PROPERTY
10
NOTE

SOLE
SEE

THE
ARE
13,000 (SEE NOTE12)

N
11,000 (SEE NOTE12)

HEREI
15

NG
FOR POLE GROUNDI
L-
SEE DETAI 1

NED
SCALE: NONE

CONTAI
REVISION VALIDATION

GROUND LEVEL THIS REVISION NO. 00 IS COVERED, FOR ALL APPROVAL AND CERTIFICATION

REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:

ON
765200-0915-001

NFORMATI
DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
(DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
L
DETAI

ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE

CONCRETE RM JAB RM JAB


09/01/15 09/01/15 09/01/15 09/01/15
ANCHOR REV.NO. DATE REVISION DESCRIPTION

I
2000 PLAN
ON

00 09/01/15 NEW STANDARD FOR STEEL POLE


POLE.

FOUNDATI

THE
NTS JOB ORDER/EWO NO.
THIS REVISION IS NOT TO BE USED FOR
765200 CONSTRUCTION UNTIL CERTIFIED AND DATED

SAUDI ARABIAN OIL COMPANY


SEE

AND
DRAWING TYPE

ARMLESS ANGLE POLE (30°-60°) STD

NG
13.8KV -34.5KV OVERHEAD POWERLINE

DRAWI
BEARING PLATE

STANDARD DRAWING
FRONT ELEVATION
STD. DWG. SAUDI ARABIA

S
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

THI
990 P AA-036142 004 00
Saudi Aramco 2615 ENG. (05/05)

RESTRICTED VECTOR CADD-01